Vous êtes sur la page 1sur 11

DRAWING TITLE:

GSKY GREEN WALL PANELS

DESIGN NOTE:
*STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM
*WALL SURFACE MUST BE SMOOTH
*WATERPROOFING IS REQUIRED TO BE APPLIED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)
*ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)
*WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)
*EMBEDDED PIPE OR CONDUIT LOCATIONS MUST BE INDICATED TO GSKY
*TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL
*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS

CONCRETE WALL STRUCTURE / INTERIOR OR EXTERIOR


3D VIEW
PLAN DETAIL

SECTION DETAIL
FASTENER DETAIL

DRAWING #

DATE:
REV DATE:

1-p

AUG 18, 2010


N/A

SCALE:
AS NOTED
PAPER SIZE: 11 x 17

#704 - 318 HOMER ST


VANCOUVER, BC V6B 2V2
604-708-0611 ph 604-357-1315 fax
www.gsky.com

CONCRETE WALL WITH


SMOOTH SURFACE

3/8" DIA SS WEDGE ANCHOR

WATERPROOFING

5"

CONCRETE WALL

GSKY TRIM MOUNTING ANGLE

SEE 10-p AND 11-p FOR


IRRIGATION DETAIL

3"

WATERPROOFING

PLAN DETAIL / CONCRETE WALL


SCALE 3/4" - 1'-0" (FILE # 1-p-2)

6 1/2"

STAINLESS OR ALUMINUM
GSKY TOP TRIM SECURE
INTO TRIM MOUNTING ANGLE

4"

5"
3"

GSKY SS FRAME

GSKY STANDARD
GREEN WALL PANEL

STAINLESS OR ALUMINUM GSKY


SIDE TRIM SECURE INTO TRIM
MOUNTING ANGLE

3/8" DIA SS WEDGE ANCHOR

CONCRETE WALL

GSKY TRIM MOUNTING


ANGLE

3/8" DIA SS WEDGE


ANCHOR

CONCRETE WALL
WITH SMOOTH
SURFACE

GSKY IRRIGATION
DRIP LINE

11 7/8"

GSKY STANDARD
GREEN WALL PANEL

NEOPRENE WASHER
BETWEEN WALL AND
GSKY FRAME

MIN 2" EMBED

GSKY SIDE TRIM

GSKY STANDARD
GREEN WALL PANEL

11 7/8" TYP.

4"

1 1/2"

GSKY TOP TRIM

6 1/2"

2"

1 1/2"

GSKY SS FRAME

GSKY FRAME
WATERPROOFING

2"

GSKY SS FRAME

SEE 8-p-2 FOR DRAIN


DETAIL

3/8" DIA SS WEDGE


ANCHOR

WATERPROOFING

3D VIEW / CONCRETE WALL


SCALE 3/8" - 1'-0" (FILE # 1-p-1)

SECTION DETAIL / CONCRETE WALL


SCALE 3/4" - 1'-0" (FILE # 1-p-3)

FASTENER DETAIL / CONCRETE WALL


SCALE 3" - 1'-0" (FILE # 1-p-4)

DRAWING TITLE:

GSKY GREEN WALL PANELS

DESIGN NOTE:
*STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM
*WALL SURFACE MUST BE SMOOTH
*CMU VOID SPACE MUST BE FILLED WITH MORTAR FOR ANCHORING
*WATERPROOFING IS REQUIRED TO BE APPLIED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)
*ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)
*WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)
*EMBEDDED PIPE OR CONDUIT LOCATIONS MUST BE INDICATED TO GSKY
*TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL
*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS

CMU WALL STRUCTURE / INTERIOR OR EXTERIOR


3D VIEW
PLAN DETAIL

SECTION DETAIL
FASTENER DETAIL

DRAWING #

DATE:
REV DATE:

2-p

AUG 18, 2010


N/A

SCALE:
AS NOTED
PAPER SIZE: 11 x 17

#704 - 318 HOMER ST


VANCOUVER, BC V6B 2V2
604-708-0611 ph 604-357-1315 fax
www.gsky.com

3/8" DIA CONCRETE


ANCHOR

CMU WALL (VOID MUST BE


FILLED)
WATERPROOFING

2"

6 1/2"

CMU WALL (VOID MUST BE FILLED)

5"

GSKY TOP TRIM

1 1/2"

GSKY SS FRAME

GSKY TRIM MOUNTING ANGLE

SEE 10-p AND 11-p FOR


IRRIGATION DETAIL

3"
11 7/8" TYP.

4"

GSKY STANDARD
GREEN WALL PANEL

STAINLESS OR ALUMINUM GSKY


SIDE TRIM SECURE INTO TRIM
MOUNTING ANGLE

GSKY SIDE TRIM


WATERPROOFING

PLAN DETAIL / CMU WALL


SCALE 3/4" - 1'-0" (FILE # 2-p-2)

GSKY SS FRAME

GSKY STANDARD
GREEN WALL PANEL

6 1/2"

STAINLESS OR ALUMINUM
GSKY TOP TRIM SECURE
INTO TRIM MOUNTING ANGLE
SEE 8-p-1 FOR
DRAIN DETAIL

3"

4"

3/8" DIA CONCRETE ANCHOR

5"

CMU WALL WITH


FILLED VOID

GSKY TRIM MOUNTING


ANGLE

3/8" DIA SS CONCRETE


ANCHOR
NEOPRENE WASHER
BETWEEN WALL AND
GSKY FRAME

CMU WALL (VOID


MUST BE FILLED)

GSKY FRAME
GSKY IRRIGATION
DRIP LINE

WATERPROOFING

3D VIEW / CMU WALL


SCALE 3/8" - 1'-0" (FILE # 2-p-1)

SECTION DETAIL / CMU WALL


SCALE 3/4" - 1'-0" (FILE # 2-p-3)

2"

GSKY SS FRAME

3/8" DIA CONCRETE


ANCHOR

WATERPROOFING

1 1/2"

11 7/8"

GSKY STANDARD
GREEN WALL PANEL

FASTENER DETAIL / CMU WALL


SCALE 3" - 1'-0" (FILE # 2-p-4)

DRAWING TITLE:

GSKY GREEN WALL PANELS

DESIGN NOTE:
*STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM
*WALL SURFACE MUST BE SMOOTH
*3/4" PLYWOOD MUST BE INSTALLED BEHIND GREEN WALL AREA
*BLOCKING AT GSKY FRAME SCREW LOCATIONS MAY BE REQUIRED CHECK WITH PROJECT ENGINEER
*STUD LOCATION MUST BE IDENTIFIED ON THE AS-BUILT DRAWING
*GREEN WALL CAN BE RECESSED AT INDOOR WALL (NOTE THAT GUTTER WILL EXTEND OUT; SEE 8-p-1 FOR DETAIL)
*WATERPROOFING IS REQUIRED TO BE APPLIED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)
*ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)
*WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)
*TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL
*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS

STUD WALL STRUCTURE / INTERIOR OR EXTERIOR


3D VIEW
PLAN DETAIL

SECTION DETAIL
FASTENER DETAIL

DRAWING #

DATE:
REV DATE:

3-p

AUG 18, 2010


N/A

SCALE:
AS NOTED
PAPER SIZE: 11 x 17

#704 - 318 HOMER ST


VANCOUVER, BC V6B 2V2
604-708-0611 ph 604-357-1315 fax
www.gsky.com

1/4" DIA WOOD OR


METAL SCREW

2x6 BLOCKING AT GSKY FRAME


SCREW LOCATION MAYBE
REQUIRED (CHECK WITH
PROJECT ENGINEER)

WOOD OR METAL STUD


WALL STRUCTURE

GSKY SS FRAME

2"

WATERPROOFING

5"

SEE 10-p AND 11-p FOR


IRRIGATION DETAIL

1 1/2"

STUD WALL STRUCTURE

GSKY TOP TRIM

3/4" PLYWOOD BEHIND GREEN


WALL

GSKY TRIM MOUNTING ANGLE

3"

GREEN WALL CAN BE


RECESSED INTO
WALL FINISH

GSKY SIDE TRIM

2x6 BLOCKING AT GSKY FRAME


SCREW LOCATIONS MAY BE
REQUIRED (CHECK WITH
PROJECT ENGINEER)

GSKY STANDARD
GREEN WALL PANEL

GSKY STANDARD
GREEN WALL PANEL

STAINLESS OR ALUMINUM GSKY


SIDE TRIM SECURE INTO TRIM
MOUNTING ANGLE

PLAN DETAIL / STUD WALL


SCALE 3/4" - 1'-0" (FILE # 3-p-2)

3/4" PLYWOOD BEHIND GREEN


WALL

6 1/2"

STAINLESS OR ALUMINUM
GSKY TOP TRIM SECURE
INTO TRIM MOUNTING ANGLE

4"

SEE 8-p-1 FOR


DRAIN DETAIL

5"

2x6 BLOCKING AT GSKY


FRAME SCREW LOCATION
MAYBE REQUIRED (CHECK
WITH PROJECT ENGINEER)

GSKY TRIM MOUNTING


ANGLE

1/4" DIA SS WOOD OR


METAL SCREW

3"

WATERPROOFING

11 7/8" TYP.

4"

1/4" DIA WOOD OR METAL


SCREW

WOOD OR METAL STUD


WALL STRUCTURE

NEOPRENE WASHER
BETWEEN WALL AND
GSKY FRAME
3/4" PLYWOOD BEHIND
GREEN WALL

GSKY IRRIGATION
DRIP LINE

GSKY STANDARD
GREEN WALL PANEL

GSKY FRAME

GSKY SS FRAME

11 7/8"

GSKY SS FRAME

WATERPROOFING

2x6 BLOCKING AT GSKY


FRAME SCREW LOCATION
MAYBE REQUIRED (CHECK
WITH PROJECT ENGINEER)

1 1/2"

WALL FINISH TO MAKE


RECESSED GREEN
WALL OPTION

2"

3/4" PLYWOOD
BEHIND GREEN WALL

1/4" DIA WOOD OR


METAL SCREW

WATERPROOFING

3D VIEW / STUD WALL


SCALE 3/8" - 1'-0" (FILE # 3-p-1)

SECTION DETAIL / STUD WALL


SCALE 3/4" - 1'-0" (FILE # 3-p-3)

FASTENER DETAIL / STUD WALL


SCALE 3" - 1'-0" (FILE # 3-p-4)

DRAWING TITLE:

GSKY GREEN WALL PANELS

DESIGN NOTE:
*STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM
*WALL SURFACE MUST BE SMOOTH
*HORIZONTAL STEEL MEMBER MUST LINE UP WITH GSKY FRAME SCREW LOCATIONS; ASK GSKY FOR CONSULTANT
*WATERPROOFING MAY BE REQUIRED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)
*ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)
*WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)
*TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL
*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS

STEEL WALL STRUCTURE / INTERIOR OR EXTERIOR


3D VIEW
PLAN DETAIL

SECTION DETAIL
FASTENER DETAIL

DRAWING #

DATE:
REV DATE:

4-p

AUG 18, 2010


N/A

SCALE:
AS NOTED
PAPER SIZE: 11 x 17

#704 - 318 HOMER ST


VANCOUVER, BC V6B 2V2
604-708-0611 ph 604-357-1315 fax
www.gsky.com

BACK COVER

STEEL STRUCTURE

INSULATION AS REQUIRED
BY GSKY

1/4" DIA SS SELF


TAPPING SCREW

INSULATION AS REQUIRED

5"

6 1/2"

GSKY SS FRAME
GSKY TOP TRIM

GSKY TRIM MOUNTING ANGLE

SEE 10-p AND 11-p FOR


IRRIGATION DETAIL

STEEL STRUCTURE

3"
GSKY STANDARD
GREEN WALL PANEL

11 7/8" TYP.

4"

STAINLESS OR ALUMINUM GSKY


SIDE TRIM SECURE INTO TRIM
MOUNTING ANGLE

BACK COVER

GSKY SIDE TRIM

PLAN DETAIL / STEEL WALL


SCALE 3/4" - 1'-0" (FILE # 3-p-2)

GSKY SS FRAME

6 1/2"

STAINLESS OR ALUMINUM
GSKY TOP TRIM SECURE
INTO TRIM MOUNTING ANGLE

STEEL STRUCTURE

11 7/8"
SOLID GROUND FINISH FOR
MAINTENANCE ACCESS BASED
ON THE SIZE OF GREEN WALL

GSKY FRAME

2"

GSKY SS FRAME

BACK COVER

1/4" DIA SS SELF


TAPPING SCREW

HORIZONTAL STEEL
MEMBER AT GSKY
FRAME SCREW
LOCATIONS

SCALE 3/8" - 1'-0" (FILE # 4-p-1)

HORIZONTAL STEEL
MEMBER AT GSKY FRAME
SCREW LOCATIONS

GSKY IRRIGATION
DRIP LINE

GSKY STANDARD
GREEN WALL PANEL

HORIZONTAL STEEL MEMBER


AT GSKY FRAME SCREW
LOCATIONS

3D VIEW / STEEL WALL

NEOPRENE WASHER
BETWEEN WALL AND
GSKY FRAME

3"

4"

1/4" DIA SS SELF TAPPING


SCREW

SEE 8-p-3 FOR


DRAIN DETAIL

5"

1/4" DIA SS SELF


TAPPING SCREW

GSKY TRIM MOUNTING


ANGLE

1 1/2"

GSKY STANDARD
GREEN WALL PANEL

HORIZONTAL STEEL MEMBER


AT GSKY FRAME SCREW
LOCATIONS BY OTHERS

1 1/2"

2"

SECTION DETAIL / STEEL WALL


SCALE 3/4" - 1'-0" (FILE # 3-p-3)

FASTENER DETAIL / STEEL WALL


SCALE 3" - 1'-0" (FILE # 4-p-4)

DRAWING TITLE:

GSKY GREEN WALL PANELS

DESIGN NOTE:
*STRUCTURE TYPE SHOWN ON 1-p, 2-p, 3-p AND 4-p CAN BE USED
*STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM
*WALL SURFACE MUST BE SMOOTH
*HORIZONTAL STEEL MEMBER MUST LINE UP WITH GSKY FRAME SCREW LOCATIONS; ASK GSKY FOR CONSULTANT
*WATERPROOFING MAY BE REQUIRED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)
*ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)
*WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)
*TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL
*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS

DOUBLE SIDED WALL STRUCTURE / INTERIOR OR EXTERIOR


3D VIEW
PLAN DETAIL

SECTION DETAIL
FASTENER DETAIL

DRAWING #

DATE:
REV DATE:

5-p

AUG 18, 2010


N/A

SCALE:
AS NOTED
PAPER SIZE: 11 x 17

#704 - 318 HOMER ST


VANCOUVER, BC V6B 2V2
604-708-0611 ph 604-357-1315 fax
www.gsky.com

1/4" DIA SS SELF


TAPPING SCREW

STAINLESS OR ALUMINUM GSKY


SIDE TRIM SECURE INTO TRIM
MOUNTING ANGLE

GSKY STANDARD
GREEN WALL PANEL
GSKY TOP TRIM

STEEL STRUCTURE

5"

6 1/2"

GSKY SS FRAME

HORIZONTAL STEEL MEMBER


AT GSKY FRAME SCREW
LOCATIONS

1 1/2"

2"

GSKY TRIM MOUNTING ANGLE

SEE 10-p AND 11-p FOR


IRRIGATION DETAIL

3"
11 7/8" TYP.

4"

GSKY SIDE TRIM

PLAN DETAIL / DOUBLE SIDED WALL


SCALE 3/4" - 1'-0" (FILE # 5-p-2)

GSKY SS FRAME

GSKY STANDARD
GREEN WALL PANEL

GSKY TRIM MOUNTING


ANGLE

STEEL STRUCTURE
BY OTHERS

GSKY IRRIGATION
DRIP LINE

11 7/8"

HORIZONTAL STEEL MEMBER


AT GSKY FRAME SCREW
LOCATIONS

5"
3"

1/4" DIA SS SELF


TAPPING SCREW

SEE 8-p-3 FOR


DRAIN DETAIL

6 1/2"

STAINLESS OR ALUMINUM
GSKY TOP TRIM SECURE
INTO TRIM MOUNTING ANGLE

4"

GSKY STANDARD
GREEN WALL PANEL

1/4" DIA SS SELF


TAPPING SCREW

GSKY SS FRAME

SOLID GROUND FINISH FOR


MAINTENANCE ACCESS BASED
ON THE SIZE OF GREEN WALL

NEOPRENE WASHER
BETWEEN WALL AND
GSKY FRAME
HORIZONTAL STEEL
MEMBER AT GSKY FRAME
SCREW LOCATIONS

1/4" DIA SS SELF


TAPPING SCREW
BY GSKY

1 1/2"

GSKY FRAME

2"

HORIZONTAL STEEL
MEMBER AT GSKY
FRAME SCREW
LOCATIONS BY OTHERS

3D VIEW / DOUBLE SIDED WALL


SCALE 3/8" - 1'-0" (FILE # 5-p-1)

SECTION DETAIL / DOUBLE SIDED WALL


SCALE 3/4" - 1'-0" (FILE # 5-p-3)

FASTENER DETAIL / DOUBLE SIDED WALL


SCALE 3" - 1'-0" (FILE # 5-p-4)

DRAWING TITLE:

GSKY GREEN WALL PANELS

DESIGN NOTE:
*STRUCTURE TYPE SHOWN ON 1-p, 2-p, 3-p AND 4-p CAN BE USED
*STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM
*WALL SURFACE MUST BE SMOOTH
*3/4" PLYWOOD MUST BE INSTALLED BEHIND GREEN WALL AREA
*BLOCKING AT GSKY FRAME SCREW LOCATIONS MUST BE INSTALLED; CHECK WITH ENVELOPE CONSULTANT FOR THERMAL BRIDGE
*WATERPROOFING IS REQUIRED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)
*ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)
*WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)
*TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL
*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS

EIFS WALL STRUCTURE / INTERIOR OR EXTERIOR


3D VIEW
PLAN DETAIL

SECTION DETAIL
FASTENER DETAIL

DRAWING #

DATE:
REV DATE:

6-p

AUG 18, 2010


N/A

SCALE:
AS NOTED
PAPER SIZE: 11 x 17

#704 - 318 HOMER ST


VANCOUVER, BC V6B 2V2
604-708-0611 ph 604-357-1315 fax
www.gsky.com

1/4" DIA WOOD OR


METAL SCREW

CONCRETE WALL WITH


SMOOTH SURFACE

GSKY SS FRAME

WATERPROOFING
BLOCKING MATERIAL TO
SECURE GSKY FRAME

1 1/2"

2"

6 1/2"

WALL FINISH

CONCRETE STRUCTURE

GSKY TOP TRIM

8 3/4"

3/4" PLYWOOD BEHIND


GREEN WALL

GSKY TRIM MOUNTING ANGLE

SEE 10-p AND 11-p FOR


IRRIGATION DETAIL

3"
11 7/8" TYP.

4"

GSKY STANDARD
GREEN WALL PANEL

STAINLESS OR ALUMINUM GSKY


SIDE TRIM SECURE INTO TRIM
MOUNTING ANGLE

WATERPROOFING

BLOCKING MATERIAL TO
SECURE GSKY FRAME BY
OTHERS (CHECK WITH
BUILDING ENVELOPE
CONSULTANT FOR THERMAL
BRIDGE)

GSKY SIDE TRIM

PLAN DETAIL / EIFS WALL


SCALE 3/4" - 1'-0" (FILE # 6-p-2)

WALL FINISH

EIFS SYSTEM

6 1/2"

STAINLESS OR ALUMINUM
GSKY TOP TRIM SECURE
INTO TRIM MOUNTING ANGLE

4"

3/4" PLYWOOD BEHIND GREEN


WALL

5"
3"

GSKY STANDARD
GREEN WALL PANEL

GSKY TRIM MOUNTING


ANGLE
BLOCKING MATERIAL TO
SECURE GSKY FRAME

SEE 8-p-4 FOR


DRAIN DETAIL
1/4" DIA WOOD OR METAL
SCREW

1/4" DIA SS WOOD OR


METAL SCREW

GSKY IRRIGATION
DRIP LINE

GSKY STANDARD
GREEN WALL PANEL

WATERPROOFING

11 7/8"

GSKY SS FRAME
GSKY SS FRAME

BLOCKING MATERIAL TO
SECURE GSKY FRAME

3/4" PLYWOOD BEHIND


GREEN WALL

NEOPRENE WASHER
BETWEEN WALL AND
GSKY FRAME

EIFS SYSTEM

3/4" PLYWOOD BEHIND


GREEN WALL

CONCRETE WALL
WITH SMOOTH
SURFACE

1 1/2"

GSKY FRAME

1/4" DIA WOOD OR


METAL SCREW

2"

WATERPROOFING

3D VIEW / EIFS WALL


SCALE 3/8" - 1'-0" (FILE # 6-p-1)

SECTION DETAIL / EIFS WALL


SCALE 3/4" - 1'-0" (FILE # 6-p-3)

FASTENER DETAIL / EIFS WALL


SCALE 3" - 1'-0" (FILE # 6-p-4)

DRAWING TITLE:

GSKY GREEN WALL PANELS


TYPICAL DETAILS / INTERIOR OR EXTERIOR
3D VIEW
CORNER TRIM

AUG 18, 2010


N/A

SCALE:
AS NOTED
PAPER SIZE: 11 x 17

#704 - 318 HOMER ST


VANCOUVER, BC V6B 2V2
604-708-0611 ph 604-357-1315 fax
www.gsky.com

GSKY CORNER
PANEL

CORNER TRIM
MOUNTING
BRACKET 3' O/C

SEE 7-p-4 FOR


GUTTER OVER
OPENING

11 7/8" TYP.

6 3/4"

5"

5"

6 3/4"

7-p

DATE:
REV DATE:

STAINLESS OR
ALUMINUM GSKY
CORNER TRIM

PLAN DETAIL / CORNER TRIM


SCALE 1" - 1'-0" (FILE # 7-p-2)

SEE 7-p-3 FOR GSKY


CORNER PANEL
DETAIL

SEE 7-p-2 FOR GSKY


CORNER TRIM
DETAIL

STAINLESS OR ALUMINUM
GSKY GUTTER DRAIN
OVER OPENING

4"

DRAWING #

CORNER PANEL
GUTTER OVER OPENING

DRAIN PIPE TO DIRECT


WATER FROM GUTTER TO
MAIN DRAINAGE (RUN
DRAIN PIPE IN SIDE TRIM)

SEE 8-p FOR MIN WIDTH

LINE OF SIDE TRIM


(TRIM WIDTH CAN
MATCH WITH WITH
GUTTER WIDTH)

3D VIEW FOR TYPICAL DETAILS


SCALE NTS (FILE # 7-p-1)

SECTION DETAIL / GUTTER OVER OPENING


SCALE 1" - 1'-0" (FILE # 7-p-4)

11 7/8" TYP.

5"

PLAN DETAIL / CORNER PANEL


SCALE 1" - 1'-0" (FILE # 7-p-3)

GSKY CORNER
PANEL MOUNTING
BRACKET

DRAWING TITLE:

GSKY GREEN WALL PANELS

HEIGHT: LESS THAN 16 PANELS

DRAIN DETAILS / INTERIOR OR EXTERIOR


GUTTER DRAIN
GRAVEL DRAIN

AUG 18, 2010


N/A

SCALE:
AS NOTED
PAPER SIZE: 11 x 17

#704 - 318 HOMER ST


VANCOUVER, BC V6B 2V2
604-708-0611 ph 604-357-1315 fax
www.gsky.com

STAINLESS OR
ALUMINUM GUTTER
DRAIN

STRIP OF MEMBRANE
OVER GUTTER

NOT ADEQUATE

NOT ADEQUATE

TRENCH DRAIN

MIN 12"

MIN 24"

MIN 36" (ASK GSKY)

GROUND DRAIN

MIN 12"

MIN 24"

MIN 36" (ASK GSKY)

CURB DRAIN

MIN 12"

MIN 24"

MIN 36" (ASK GSKY)

*DRAIN AREA SHOULD EXTEND MIN 1/2 DRAIN WIDTH FROM EACH SIDES OF GREEN WALL
*MIN WIDTH MAY CHANGE DEPENDING ON PLANT SELECTION
*WATERPROOFING IN TRENCH AND CURB DRAIN ARE REQUIRED
*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS

TRENCH DRAIN AREA

WATERPROOFING

SLOPED FLOOR FINISH

6"

2" DRAIN PIPE WITH


SCREEN COVER

SEE TABLE FOR MIN WIDTH


2" DRAIN PIPE WITH
SCREEN COVER

SEE TABLE FOR MIN WIDTH

SECTION DETAIL / GUTTER DRAIN


SCALE 1" - 1'-0" (FILE # 8-p-1)

SECTION DETAIL / TRENCH DRAIN


SCALE 1" - 1'-0" (FILE # 8-p-2)

DRAIN AREA WITH


GRAVEL

FINISHED CURB
AROUND DRAIN AREA

DRAIN AREA WITH


GRAVEL

WATERPROOFING
WATERPROOFING

MIN 6"

HARD SURFACE FOR


MAINTENANCE WITH LIFT

PERFORATED
DRAINAGE PIPE

SEE TABLE FOR MIN WIDTH


2" DRAIN PIPE WITH
SCREEN COVER

SEE TABLE FOR MIN WIDTH

SECTION DETAIL / GRAVEL DRAIN


SCALE 1" - 1'-0" (FILE # 8-p-3)

HEIGHT: MORE THAN 24 PANELS

MIN 12"

METAL GRATING COVER

MIN 6"

8-p

DATE:
REV DATE:

4"

DRAWING #

TRENCH DRAIN
CURB DRAIN

HEIGHT: BETWEEN 16 AND 24 PANELS

GUTTER DRAIN

SECTION DETAIL / CURB DRAIN


SCALE 1" - 1'-0" (FILE # 8-p-4)

DRAWING TITLE:

GSKY GREEN WALL PANELS


IRRIGATION CONTROL UNIT (ICU) DESIGNS
ICU-1000
ICU-600

AUG 18, 2010


N/A

SCALE:
AS NOTED
PAPER SIZE: 11 x 17

#704 - 318 HOMER ST


VANCOUVER, BC V6B 2V2
604-708-0611 ph 604-357-1315 fax
www.gsky.com

ICU-1000

ICU-600
IRRIGATION CONTROL UNIT FOR:
*GREEN WALLS SMALLER THAN 1080 SQFT (INTERIOR OR EXTERIOR)
*EXTERIOR WALLS IN USDA PLANT ZONE 9 OR HIGHER (NON-FREEZING
CLIMATES)

IRRIGATION CONTROL UNIT FOR:


*GREEN WALLS LARGER THAN 1080SQFT (INTERIOR OR EXTERIOR)
*EXTERIOR GREEN WALLS IN FREEZING CLIMATES USDA PLANT
ZONE 8 OR BELOW (USDA PLANT ZONE 8 = MAX 20F OR -6.7C)
CONTROLLER / TIMER

1'-3"

CONTROLLER / TIMER

2'

1'-3"

3'

PRESSURE REGULATION
VALVE

1" IRRIGATION MAIN LINE


INLET (SIZE MAY VARY)
PRESSURE REGULATION
VALVE
MASTER VALVE

HARD WIRE CONNECTION


120 VAC / 2 AMP IN CONDUIT
BY ELECTRICIAN

HARD WIRE CONNECTION


120 VAC / 2 AMP IN CONDUIT
BY ELECTRICIAN

DEDICATED TELEPHONE LINE


WITH RJ 11 CONNECTION BY
ELECTRICIAN

1'-1"

1" IRRIGATION MAIN LINE


INLET (SIZE MAY VARY)

DEDICATED TELEPHONE LINE


WITH RJ 11 CONNECTION BY
ELECTRICIAN

FLOW SENSOR
REQUIRES MIN. 1'
STRAIGHT PIPE BEFORE
AND AFTER THE SENSOR

CONDUIT WITH 16 GA SOLID


COPPER MULTI-STRAND
CABLE BY OTHERS
(# OF WIRES DETERMINED BY
# OF IRRIGATION ZONES AND
SENSORS ON THE WALL)

4'

FERTILIZER INJECTOR

4'

9-p

DATE:
REV DATE:

1'-1"

DRAWING #

PLUMBING REQUIREMENTS
ELECTRICAL REQUIREMENTS

1" CONDUIT BY G-SKY

1" CONDUIT BY G-SKY


FERTILIZER INJECTOR

DEDICATED IRRIGATION ZONE


SUPPLY LINES FROM ICU TO
GREEN WALL BY OTHERS
1" FIPT STUB-OUTS ARE REQUIRED

FERTILIZER TANK

FLOW SENSOR
REQUIRES MIN. 1' STRAIGHT
PIPE BEFORE AND AFTER
THE SENSOR
GRAVITY DRAIN VALVE FOR
AUTOMATED WINTERIZATION

FERTILIZER TANK

DEDICATED IRRIGATION ZONE


SUPPLY LINES FROM ICU TO
GREEN WALL BY OTHERS
3/4" FIPT STUB-OUTS ARE
REQUIRED; 1" SUPPLY LINE
MAY BE USED TO KEEP FLOW
TO STUB-OUT

*REQUIREMENTS:
*ICU - 48"h x 24"w x 36"d (INCLUDING DOOR SWING)
*CONTROLLER - 13"h x 15"w x 20"d (INCLUDING DOOR SWING)
*EASY ACCESS FOR MAINTENANCE
*ADEQUATE PRESSURE TO GET MIN PSI AT BOTTOM OF GREEN WALL (TYP
65 PSI, UP TO 50 FT HEIGHT WALL)
INSTALL BOOSTER PUMP IF REQUIRED (BY PLUMBER)
*120V / 2 AMP POWER (HARD WIRE) (BY ELECTRICIAN)
*DEDICATED TELEPHONE LINE RJ 11 (FOR OTHERS)
*GROUNDING CONNECTION IF REQUIRED (BY ELECTRICIAN)
*1 1/4" CONDUIT BETWEEN ACC AND EACH TRIM SPACES FOR ZONE VALVE
CONTROL WIRES AND FREEZING SENSOR (BY ELECTRICIAN)
*BACK-FLOW PREVENTOR AS REQUIRED (BY PLUMBER)
*GREEN WALL MUST BE DESIGNED TO HAVE SPACE FOR ZONE VALVES TO
RUN ALONG THE SIDE OF THE GREEN WALL WITHIN THE SIDE TRIM (MIN 7"
WIDE TRIM) OR ABOVE THE WALL IN THE TOP TRIM (MIN 8" HIGH TRIM)
*NON-FREEZING INDOOR SPACE WITH FLOOR DRAIN

ICU-1000 / ZONE VALVES AT GREEN WAL


SCALE 3/4" - 1'-0" (FILE # 9-p-1)

*REQUIREMENTS:
*ICU - 48"h x 36"w x 48"d (INCLUDING DOOR SWING)
*CONTROLLER - 13"h x 15"w x 20"d (INCLUDING DOOR SWING)
*EASY ACCESS FOR MAINTENANCE
*ADEQUATE PRESSURE TO GET MIN PSI AT BOTTOM OF GREEN WALL (TYP
65 PSI, UP TO 50 FT HEIGHT WALL)
INSTALL BOOSTER PUMP IF REQUIRED (BY PLUMBER)
*120V / 2 AMP POWER (HARD WIRE) (BY ELECTRICIAN)
*DEDICATED TELEPHONE LINE RJ 11 (BY OTHERS)
*GROUNDING CONNECTION IF REQUIRED (BY ELECTRICIAN)
*BACK-FLOW PREVENTOR AS REQUIRED (BY PLUMBER)
*CAN BE EXPANDED MAX 6 ZONES TO ACCOMMODATE IF THERE IS NO
SPACE FOR VALVES AT THE GREEN WALL(S)
*NON-FREEZING INDOOR SPACE WITH FLOOR DRAIN
*CAN BE LOCATED OUTDOORS WITH ADDITIONAL ENCLOSURE
*CAN BE CUSTOM DESIGNED TO ACCOMMODATE FREEZING CLIMATES

ICU-600 / ZONE VALVES AT ICU


SCALE 3/4" - 1'-0" (FILE # 9-p-2)

DRAWING TITLE:

GSKY GREEN WALL PANELS


IRRIGATION LAYOUT 1
IRRIGATION LAYOUT FOR ICU-1000
IRRIGATION LAYOUT FOR ICU-600
DRAWING #

DATE:
REV DATE:

10-p

MAX. 36 PANELS IN EACH CONTINUOUS ROW


MAX. 5 PANELS HEIGHT IN ONE ZONE
MAIN IRRIGATION SUPPLY LINE CAN BE COPPER, PEX OR PVC TO MEET
LOCAL CODE (BY PLUMBER)
STUB-OUT SHOULD BE INSTALLED WITH FEMALE PIPE THREAD FITTINGS

STUB-OUT DETAIL
ZONE VALVE DETAIL

AUG 18, 2010


N/A

SCALE:
AS NOTED
PAPER SIZE: 11 x 17

#704 - 318 HOMER ST


VANCOUVER, BC V6B 2V2
604-708-0611 ph 604-357-1315 fax
www.gsky.com

MAX 5 PANELS HEIGHT IN SINGLE ZONE

MAX 36 PANELS IN SINGLE ROW

S
MAX 2"

CAN BE IN SAME ZONE IF 3 OUT


OF 5 ROWS IN SINGLE ZONE
ARE CONTIUOUS

3/4" FIPT IRRIGATION


STU-OUT BY OTHERS
SEE DRAWING #1 FOR
STUB-OUT LOCATIONS

IF MORE THAN 3 OUT 5 ROWS


ARE TERMINATED BY OPENING,
REQUIRE ANOTHER STUB-OUT

3/4" STUB-OUT WITH FIPT


CONNECTION (MAIN LINE
MAY BE 1" TO KEEP FLOW)

1 1/2"

4"

IRRIGATION LAYOUT FOR ICU-600 / ZONE VALVES AT ICU

SCALE NTS (FILE # 10-p-1)

SINGLE IRRIGATION STUB-OUT


AND CONDUIT FOR ICU-1000; SEE
9-p FOR REQUIREMENTS

LOCATE ZONE VALVES WITH IN


TOP TRIM SPACE; MIN 8" TOP TRIM
SPACE IS REQUIRED

GSKY TOP TRIM

6 1/2"

Z Z

F
CONTROL WIRES
(FREE WIRED OR IN
CONDUIT)

8"

MAX 5 PANELS HEIGHT IN SINGLE ZONE

SCALE 1-1/2" = 1'-0" (FILE # 10-p-2)

1" IRRIGATION
SUPPLY LINE FROM
STUB-OUT

INSTALL FREEZING AND REV


FREEZING SENSOR FOR
FREEZING REGION

MAX 36 PANELS IN SINGLE ROW

Z Z

IRRIGATION STUB-OUT DETAIL FOR ICU-600

ZONE VALVES

LOCATE DRAIN VALVES AT


BOTTOM OF EACH ZONE FOR
FREEZING REGION

IRRIGATION LAYOUT FOR ICU-1000 / ZONE VALVES IN TOP TRIM


SCALE NTS (FILE # 10-p-3)

ZONE VALVE DETAIL FOR ICU-1000 IN TOP TRIM


SCALE 1-1/2" = 1'-0" (FILE # 10-p-4)

DRAWING TITLE:

GSKY GREEN WALL PANELS


IRRIGATION LAYOUT 2
-

IRRIGATION LAYOUT FOR ICU-1000


ZONE VALVE DETAIL
DRAWING #

11-p

DATE:
REV DATE:

AUG 18, 2010


N/A

SCALE:
AS NOTED
PAPER SIZE: 11 x 17

#704 - 318 HOMER ST


VANCOUVER, BC V6B 2V2
604-708-0611 ph 604-357-1315 fax
www.gsky.com

MAX. 36 PANELS IN EACH CONTINUOUS ROW


MAX. 5 PANELS HEIGHT IN ONE ZONE
MAIN IRRIGATION SUPPLY LINE CAN BE COPPER, PEX OR PVC TO MEET
LOCAL CODE (BY PLUMBER)
STUB-OUT SHOULD BE INSTALLED WITH FEMALE PIPE THREAD FITTINGS

MAX 36 PANELS IN SINGLE ROW


INSTALL FREEZING AND REV
FREEZING SENSOR FOR
FREEZING REGION

1" IRRIGATION
SUPPLY LINE FROM
STUB-OUT

LOCATE ZONE VALVES WITH IN


SIDE TRIM SPACE; MIN 6" SIDE
TRIM SPACE IS REQUIRED

CONTROL WIRES
(FREE WIRED OR IN
CONDUIT)

ZONE VALVES

6 1/2"

Z
D

MAX 50 PANELS HEIGHT

MAX 5 PANELS HEIGHT IN SINGLE ZONE

GSKY TOP TRIM

Z
D

LOCATE DRAIN VALVES AT


BOTTOM OF EACH ZONE FOR
FREEZING REGION

Z
D
Z

SINGLE IRRIGATION STUB-OUT


AND CONDUIT FOR ICU-1000; SEE
8-p FOR REQUIREMENTS

D
S C

IRRIGATION LAYOUT FOR ICU-1000 / ZONE VALVES IN SIDE TRIM


SCALE NTS (FILE # 11-p-1)

6"
7"

ZONE VALVE DETAIL FOR ICU-1000 IN TOP TRIM


SCALE 1-1/2" = 1'-0" (FILE # 11-p-2)

Vous aimerez peut-être aussi