DESIGN NOTE:
*STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM
*WALL SURFACE MUST BE SMOOTH
*WATERPROOFING IS REQUIRED TO BE APPLIED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)
*ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)
*WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)
*EMBEDDED PIPE OR CONDUIT LOCATIONS MUST BE INDICATED TO GSKY
*TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL
*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS
SECTION DETAIL
FASTENER DETAIL
DRAWING #
DATE:
REV DATE:
1-p
SCALE:
AS NOTED
PAPER SIZE: 11 x 17
WATERPROOFING
5"
CONCRETE WALL
3"
WATERPROOFING
6 1/2"
STAINLESS OR ALUMINUM
GSKY TOP TRIM SECURE
INTO TRIM MOUNTING ANGLE
4"
5"
3"
GSKY SS FRAME
GSKY STANDARD
GREEN WALL PANEL
CONCRETE WALL
CONCRETE WALL
WITH SMOOTH
SURFACE
GSKY IRRIGATION
DRIP LINE
11 7/8"
GSKY STANDARD
GREEN WALL PANEL
NEOPRENE WASHER
BETWEEN WALL AND
GSKY FRAME
GSKY STANDARD
GREEN WALL PANEL
11 7/8" TYP.
4"
1 1/2"
6 1/2"
2"
1 1/2"
GSKY SS FRAME
GSKY FRAME
WATERPROOFING
2"
GSKY SS FRAME
WATERPROOFING
DRAWING TITLE:
DESIGN NOTE:
*STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM
*WALL SURFACE MUST BE SMOOTH
*CMU VOID SPACE MUST BE FILLED WITH MORTAR FOR ANCHORING
*WATERPROOFING IS REQUIRED TO BE APPLIED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)
*ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)
*WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)
*EMBEDDED PIPE OR CONDUIT LOCATIONS MUST BE INDICATED TO GSKY
*TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL
*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS
SECTION DETAIL
FASTENER DETAIL
DRAWING #
DATE:
REV DATE:
2-p
SCALE:
AS NOTED
PAPER SIZE: 11 x 17
2"
6 1/2"
5"
1 1/2"
GSKY SS FRAME
3"
11 7/8" TYP.
4"
GSKY STANDARD
GREEN WALL PANEL
GSKY SS FRAME
GSKY STANDARD
GREEN WALL PANEL
6 1/2"
STAINLESS OR ALUMINUM
GSKY TOP TRIM SECURE
INTO TRIM MOUNTING ANGLE
SEE 8-p-1 FOR
DRAIN DETAIL
3"
4"
5"
GSKY FRAME
GSKY IRRIGATION
DRIP LINE
WATERPROOFING
2"
GSKY SS FRAME
WATERPROOFING
1 1/2"
11 7/8"
GSKY STANDARD
GREEN WALL PANEL
DRAWING TITLE:
DESIGN NOTE:
*STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM
*WALL SURFACE MUST BE SMOOTH
*3/4" PLYWOOD MUST BE INSTALLED BEHIND GREEN WALL AREA
*BLOCKING AT GSKY FRAME SCREW LOCATIONS MAY BE REQUIRED CHECK WITH PROJECT ENGINEER
*STUD LOCATION MUST BE IDENTIFIED ON THE AS-BUILT DRAWING
*GREEN WALL CAN BE RECESSED AT INDOOR WALL (NOTE THAT GUTTER WILL EXTEND OUT; SEE 8-p-1 FOR DETAIL)
*WATERPROOFING IS REQUIRED TO BE APPLIED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)
*ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)
*WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)
*TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL
*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS
SECTION DETAIL
FASTENER DETAIL
DRAWING #
DATE:
REV DATE:
3-p
SCALE:
AS NOTED
PAPER SIZE: 11 x 17
GSKY SS FRAME
2"
WATERPROOFING
5"
1 1/2"
3"
GSKY STANDARD
GREEN WALL PANEL
GSKY STANDARD
GREEN WALL PANEL
6 1/2"
STAINLESS OR ALUMINUM
GSKY TOP TRIM SECURE
INTO TRIM MOUNTING ANGLE
4"
5"
3"
WATERPROOFING
11 7/8" TYP.
4"
NEOPRENE WASHER
BETWEEN WALL AND
GSKY FRAME
3/4" PLYWOOD BEHIND
GREEN WALL
GSKY IRRIGATION
DRIP LINE
GSKY STANDARD
GREEN WALL PANEL
GSKY FRAME
GSKY SS FRAME
11 7/8"
GSKY SS FRAME
WATERPROOFING
1 1/2"
2"
3/4" PLYWOOD
BEHIND GREEN WALL
WATERPROOFING
DRAWING TITLE:
DESIGN NOTE:
*STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM
*WALL SURFACE MUST BE SMOOTH
*HORIZONTAL STEEL MEMBER MUST LINE UP WITH GSKY FRAME SCREW LOCATIONS; ASK GSKY FOR CONSULTANT
*WATERPROOFING MAY BE REQUIRED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)
*ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)
*WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)
*TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL
*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS
SECTION DETAIL
FASTENER DETAIL
DRAWING #
DATE:
REV DATE:
4-p
SCALE:
AS NOTED
PAPER SIZE: 11 x 17
BACK COVER
STEEL STRUCTURE
INSULATION AS REQUIRED
BY GSKY
INSULATION AS REQUIRED
5"
6 1/2"
GSKY SS FRAME
GSKY TOP TRIM
STEEL STRUCTURE
3"
GSKY STANDARD
GREEN WALL PANEL
11 7/8" TYP.
4"
BACK COVER
GSKY SS FRAME
6 1/2"
STAINLESS OR ALUMINUM
GSKY TOP TRIM SECURE
INTO TRIM MOUNTING ANGLE
STEEL STRUCTURE
11 7/8"
SOLID GROUND FINISH FOR
MAINTENANCE ACCESS BASED
ON THE SIZE OF GREEN WALL
GSKY FRAME
2"
GSKY SS FRAME
BACK COVER
HORIZONTAL STEEL
MEMBER AT GSKY
FRAME SCREW
LOCATIONS
HORIZONTAL STEEL
MEMBER AT GSKY FRAME
SCREW LOCATIONS
GSKY IRRIGATION
DRIP LINE
GSKY STANDARD
GREEN WALL PANEL
NEOPRENE WASHER
BETWEEN WALL AND
GSKY FRAME
3"
4"
5"
1 1/2"
GSKY STANDARD
GREEN WALL PANEL
1 1/2"
2"
DRAWING TITLE:
DESIGN NOTE:
*STRUCTURE TYPE SHOWN ON 1-p, 2-p, 3-p AND 4-p CAN BE USED
*STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM
*WALL SURFACE MUST BE SMOOTH
*HORIZONTAL STEEL MEMBER MUST LINE UP WITH GSKY FRAME SCREW LOCATIONS; ASK GSKY FOR CONSULTANT
*WATERPROOFING MAY BE REQUIRED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)
*ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)
*WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)
*TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL
*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS
SECTION DETAIL
FASTENER DETAIL
DRAWING #
DATE:
REV DATE:
5-p
SCALE:
AS NOTED
PAPER SIZE: 11 x 17
GSKY STANDARD
GREEN WALL PANEL
GSKY TOP TRIM
STEEL STRUCTURE
5"
6 1/2"
GSKY SS FRAME
1 1/2"
2"
3"
11 7/8" TYP.
4"
GSKY SS FRAME
GSKY STANDARD
GREEN WALL PANEL
STEEL STRUCTURE
BY OTHERS
GSKY IRRIGATION
DRIP LINE
11 7/8"
5"
3"
6 1/2"
STAINLESS OR ALUMINUM
GSKY TOP TRIM SECURE
INTO TRIM MOUNTING ANGLE
4"
GSKY STANDARD
GREEN WALL PANEL
GSKY SS FRAME
NEOPRENE WASHER
BETWEEN WALL AND
GSKY FRAME
HORIZONTAL STEEL
MEMBER AT GSKY FRAME
SCREW LOCATIONS
1 1/2"
GSKY FRAME
2"
HORIZONTAL STEEL
MEMBER AT GSKY
FRAME SCREW
LOCATIONS BY OTHERS
DRAWING TITLE:
DESIGN NOTE:
*STRUCTURE TYPE SHOWN ON 1-p, 2-p, 3-p AND 4-p CAN BE USED
*STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM
*WALL SURFACE MUST BE SMOOTH
*3/4" PLYWOOD MUST BE INSTALLED BEHIND GREEN WALL AREA
*BLOCKING AT GSKY FRAME SCREW LOCATIONS MUST BE INSTALLED; CHECK WITH ENVELOPE CONSULTANT FOR THERMAL BRIDGE
*WATERPROOFING IS REQUIRED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)
*ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)
*WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)
*TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL
*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS
SECTION DETAIL
FASTENER DETAIL
DRAWING #
DATE:
REV DATE:
6-p
SCALE:
AS NOTED
PAPER SIZE: 11 x 17
GSKY SS FRAME
WATERPROOFING
BLOCKING MATERIAL TO
SECURE GSKY FRAME
1 1/2"
2"
6 1/2"
WALL FINISH
CONCRETE STRUCTURE
8 3/4"
3"
11 7/8" TYP.
4"
GSKY STANDARD
GREEN WALL PANEL
WATERPROOFING
BLOCKING MATERIAL TO
SECURE GSKY FRAME BY
OTHERS (CHECK WITH
BUILDING ENVELOPE
CONSULTANT FOR THERMAL
BRIDGE)
WALL FINISH
EIFS SYSTEM
6 1/2"
STAINLESS OR ALUMINUM
GSKY TOP TRIM SECURE
INTO TRIM MOUNTING ANGLE
4"
5"
3"
GSKY STANDARD
GREEN WALL PANEL
GSKY IRRIGATION
DRIP LINE
GSKY STANDARD
GREEN WALL PANEL
WATERPROOFING
11 7/8"
GSKY SS FRAME
GSKY SS FRAME
BLOCKING MATERIAL TO
SECURE GSKY FRAME
NEOPRENE WASHER
BETWEEN WALL AND
GSKY FRAME
EIFS SYSTEM
CONCRETE WALL
WITH SMOOTH
SURFACE
1 1/2"
GSKY FRAME
2"
WATERPROOFING
DRAWING TITLE:
SCALE:
AS NOTED
PAPER SIZE: 11 x 17
GSKY CORNER
PANEL
CORNER TRIM
MOUNTING
BRACKET 3' O/C
11 7/8" TYP.
6 3/4"
5"
5"
6 3/4"
7-p
DATE:
REV DATE:
STAINLESS OR
ALUMINUM GSKY
CORNER TRIM
STAINLESS OR ALUMINUM
GSKY GUTTER DRAIN
OVER OPENING
4"
DRAWING #
CORNER PANEL
GUTTER OVER OPENING
11 7/8" TYP.
5"
GSKY CORNER
PANEL MOUNTING
BRACKET
DRAWING TITLE:
SCALE:
AS NOTED
PAPER SIZE: 11 x 17
STAINLESS OR
ALUMINUM GUTTER
DRAIN
STRIP OF MEMBRANE
OVER GUTTER
NOT ADEQUATE
NOT ADEQUATE
TRENCH DRAIN
MIN 12"
MIN 24"
GROUND DRAIN
MIN 12"
MIN 24"
CURB DRAIN
MIN 12"
MIN 24"
*DRAIN AREA SHOULD EXTEND MIN 1/2 DRAIN WIDTH FROM EACH SIDES OF GREEN WALL
*MIN WIDTH MAY CHANGE DEPENDING ON PLANT SELECTION
*WATERPROOFING IN TRENCH AND CURB DRAIN ARE REQUIRED
*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS
WATERPROOFING
6"
FINISHED CURB
AROUND DRAIN AREA
WATERPROOFING
WATERPROOFING
MIN 6"
PERFORATED
DRAINAGE PIPE
MIN 12"
MIN 6"
8-p
DATE:
REV DATE:
4"
DRAWING #
TRENCH DRAIN
CURB DRAIN
GUTTER DRAIN
DRAWING TITLE:
SCALE:
AS NOTED
PAPER SIZE: 11 x 17
ICU-1000
ICU-600
IRRIGATION CONTROL UNIT FOR:
*GREEN WALLS SMALLER THAN 1080 SQFT (INTERIOR OR EXTERIOR)
*EXTERIOR WALLS IN USDA PLANT ZONE 9 OR HIGHER (NON-FREEZING
CLIMATES)
1'-3"
CONTROLLER / TIMER
2'
1'-3"
3'
PRESSURE REGULATION
VALVE
1'-1"
FLOW SENSOR
REQUIRES MIN. 1'
STRAIGHT PIPE BEFORE
AND AFTER THE SENSOR
4'
FERTILIZER INJECTOR
4'
9-p
DATE:
REV DATE:
1'-1"
DRAWING #
PLUMBING REQUIREMENTS
ELECTRICAL REQUIREMENTS
FERTILIZER TANK
FLOW SENSOR
REQUIRES MIN. 1' STRAIGHT
PIPE BEFORE AND AFTER
THE SENSOR
GRAVITY DRAIN VALVE FOR
AUTOMATED WINTERIZATION
FERTILIZER TANK
*REQUIREMENTS:
*ICU - 48"h x 24"w x 36"d (INCLUDING DOOR SWING)
*CONTROLLER - 13"h x 15"w x 20"d (INCLUDING DOOR SWING)
*EASY ACCESS FOR MAINTENANCE
*ADEQUATE PRESSURE TO GET MIN PSI AT BOTTOM OF GREEN WALL (TYP
65 PSI, UP TO 50 FT HEIGHT WALL)
INSTALL BOOSTER PUMP IF REQUIRED (BY PLUMBER)
*120V / 2 AMP POWER (HARD WIRE) (BY ELECTRICIAN)
*DEDICATED TELEPHONE LINE RJ 11 (FOR OTHERS)
*GROUNDING CONNECTION IF REQUIRED (BY ELECTRICIAN)
*1 1/4" CONDUIT BETWEEN ACC AND EACH TRIM SPACES FOR ZONE VALVE
CONTROL WIRES AND FREEZING SENSOR (BY ELECTRICIAN)
*BACK-FLOW PREVENTOR AS REQUIRED (BY PLUMBER)
*GREEN WALL MUST BE DESIGNED TO HAVE SPACE FOR ZONE VALVES TO
RUN ALONG THE SIDE OF THE GREEN WALL WITHIN THE SIDE TRIM (MIN 7"
WIDE TRIM) OR ABOVE THE WALL IN THE TOP TRIM (MIN 8" HIGH TRIM)
*NON-FREEZING INDOOR SPACE WITH FLOOR DRAIN
*REQUIREMENTS:
*ICU - 48"h x 36"w x 48"d (INCLUDING DOOR SWING)
*CONTROLLER - 13"h x 15"w x 20"d (INCLUDING DOOR SWING)
*EASY ACCESS FOR MAINTENANCE
*ADEQUATE PRESSURE TO GET MIN PSI AT BOTTOM OF GREEN WALL (TYP
65 PSI, UP TO 50 FT HEIGHT WALL)
INSTALL BOOSTER PUMP IF REQUIRED (BY PLUMBER)
*120V / 2 AMP POWER (HARD WIRE) (BY ELECTRICIAN)
*DEDICATED TELEPHONE LINE RJ 11 (BY OTHERS)
*GROUNDING CONNECTION IF REQUIRED (BY ELECTRICIAN)
*BACK-FLOW PREVENTOR AS REQUIRED (BY PLUMBER)
*CAN BE EXPANDED MAX 6 ZONES TO ACCOMMODATE IF THERE IS NO
SPACE FOR VALVES AT THE GREEN WALL(S)
*NON-FREEZING INDOOR SPACE WITH FLOOR DRAIN
*CAN BE LOCATED OUTDOORS WITH ADDITIONAL ENCLOSURE
*CAN BE CUSTOM DESIGNED TO ACCOMMODATE FREEZING CLIMATES
DRAWING TITLE:
DATE:
REV DATE:
10-p
STUB-OUT DETAIL
ZONE VALVE DETAIL
SCALE:
AS NOTED
PAPER SIZE: 11 x 17
S
MAX 2"
1 1/2"
4"
6 1/2"
Z Z
F
CONTROL WIRES
(FREE WIRED OR IN
CONDUIT)
8"
1" IRRIGATION
SUPPLY LINE FROM
STUB-OUT
Z Z
ZONE VALVES
DRAWING TITLE:
11-p
DATE:
REV DATE:
SCALE:
AS NOTED
PAPER SIZE: 11 x 17
1" IRRIGATION
SUPPLY LINE FROM
STUB-OUT
CONTROL WIRES
(FREE WIRED OR IN
CONDUIT)
ZONE VALVES
6 1/2"
Z
D
Z
D
Z
D
Z
D
S C
6"
7"