COMBUSTION ANALYSIS

POWER PLANT ENGINEERING

Fuel As Fired

Element Percent
C
65.54
H2
6.25
O2
12.74
N2
1.27
S
1.96
Ash
12.24
Moisture
3.98
Total

Corrected Value
Oxygen Exhausted
Equation
Value (%)
Equation
Value
65.54 ( 32/12 ) x 0.6554
1.7477
H2' = H2 - 1/9 M 5.80778 ( 32/4 ) x 0.0581
0.4646
O2' = O2 - 8/9 M 9.20222
-0.0920
1.27
1.96
( 32/32 ) x 0.0196
0.0196
12.24
3.98
100
Total O2 =
2.14

Proximate Analysis
FC
Fixed Carbon
VM
Volatile Matter
M
Moisture
A
Ash
Total

2.14
0.232
1073 K

Wt =
46.58
41.64
4.84
6.94
100

T/ P =

101.325 103

FUEL

Wt =

Wt = theoretical
amount of Air

9.22

Combustion
Chamber
kg of air
kg of fuel

9.22

kg of air
kg of fuel

= 10.59103

Ultimate Analysis
As Fired

CHONSAM = 100%
=1

kg
kg of fuel

Wet Product
of Combustion

1 + 9.22
=
10.22
CO

DRY PRODUCTS
CO2
=
2.403
SO2
=
0.039
N2
=
7.096617
Total
9.539
WET PRODUCTS
M
=
0.5227
Total 10.0617
kg
=
=

10.22 10.0617
0.16 kg

Gatan, Reyzelle
BSME V-1
Ultimate Analysis
As Fired
CHONSAM

COMBUSTION ANALYSIS

FUEL
= 100%
=1
Wt =

Wt = theoretical
amount of Air

9.22

DRY PRODUCTS
Mass
R
C
+ 2
0.6554
1.748
2. S
+ 2
0.0196
0.0196

3
2
0.0127 + 0.768
=
4. C
+ 2
1.

POWER PLANT ENGINEERING

Combustion
Chamber

1 + 9.22
= 10.22

kg of air
kg of fuel

T/ P

Volume

2.403

0.18896 10.59103 4.808877

0.039

0.12991 10.59103 0.053929

( 9.22)

7.096617

3
0.29686 10.5910
22.30997

7.0966
=

0.16

0.29692 10.59103 0.510019


Total
27.6828

WET PRODUCTS
5 2 + 2
0.058078 0.4646

0.5227

Wet Product
of Combustion

0.46161 10.59103 2.555193


Grand total = 30.23799

kg

Gatan, Reyzelle
BSME V-1
Volumetric Analysis (Dry)
4.81
=
CO2 =
17.37%
27.68
0.05
SO2 =
0.19%
=
27.68
22.31
N2 =
80.59%
=
27.68
0.51
=
CO =
1.84%
27.68
Total =
100%

CO2
SO2
N2
CO
Total =

CO2
SO2
N2
CO
H2O
Total =

COMBUSTION ANALYSIS
Volumetric Analysis (Wet)
4.81
= 15.90%
CO2 =
30.23799
0.05
SO2 =
= 0.18%
30.23799
22.31
N2 =
= 73.78%
30.23799
0.51
= 1.69%
CO =
30.23799
2.555193
= 8.45%
H2O =
30.23799
Total =
100%

Gravimetric Analysis (Dry)


2.40
=
24.77%
2.40
9.70
0.04
=
0.40%
0.04
9.70
7.10
73.15%
=
7.10
9.70
0.16
=
1.67%
9.70
0.16
9.70
Total =
100%
Gravimetric Analysis (Wet)
2.40
=
23.51%
2.40
10.22
0.04
0.38%
=
0.04
10.22
7.10
69.41%
=
10.22
7.10
0.16
=
1.59%
0.16
10.22
0.52
=
5.11%
10.22
0.52
10.22
Total =
100%

POWER PLANT ENGINEERING