PROPOSED NEW BOUNDARY

FENCE FOR MR. ASHOK PRASAD


SUVA, FIJI

SCHEDULE OF DRAWINGS
SHEET NUMBER

SHEET TITLE

A01

LOCALITY PLAN

A02

FENCE PLAN

A03

ELEVATIONS

A04

ELEVATIONS

A05

ELEVATIONS

A06

ELEVATIONS

S01

STRUCTURAL NOTES

S02

FOUNDATION PLAN

S03

FOOTING DETAILS

S04

COLUMN & RETAINING WALL DETAILS

S05

TYP. WALL DETAILS

S06

GATE DETAILS

S07

CONSTRUCTION DETAILS

Engineering
& Architectural
Consultants
Unit 10 Tongilava Plaza, Taufa'ahau Rd., Fanga
Nuku'alofa, Tonga. Ph/Fax (676) 28807 / 28412

14.17

Na
bu

AD
RO

l
SS3681 (SO4346) sea
E:1968585.63
N:3875685.56
RL : 14.96
15

CM 2
U 3'
BO
U

26.72

BOU

NDA

RY F

ENC
E

(56
.84
)

LOT
53
DP
2320
1105m

30.51

14.2
5

SITE PLAN

26.97

30.18
29.70

27.09
26.88

Water
Meter
30.59

tree

27.11 26.63

SCALE 1 : 500

26.82

26.87
26.73

to Raiwasa Road

26.53

Mead Rd

NABUA SQUATTERS COMMUNITY


LOT
46
DP
2320

G ay

Sco
tt S

Amy St

Brown
St

n
to
er
ilv

Suva
St

la B

ay
Rd

Fera Stadio
University of the
South Pacific

NASESE

LOCALITY PLAN
SCALE 1 : 500

Rd
d

Vuya Rd

Queen Elizabeth Rd

Ratu Su
kuna R

Lau
ca

MUANIVATU
SQUATTER
SETTLEMENT

E li
za
be
th

au Roa

u
Ba

Domain Rd

Fiji Museum

ys
St

Rd

Q
ue
en

Cakub

Kn
oll

Ratu Sukuna Rd

Suva
City Center

Rd

Granth
am Rd

Rewa
Rd

Rd

ai
m
an
u

i
Ed

gh
ur
nb
Rd

Fo
ste
r

Rd

26.53

Power
Pole

R ST
REE
T

20"

200
MM
CMU

29.74

of

32.5
9

Rd

seal

sR
d

28.11

ew
ay

Kin
g

r iv

30

44'

LOT
7
DP
2319

re
te
D

T
LO
47
DP
0
232

Exist. 2-Storey
Concrete Bldg

53

le

291

6.

Ga
te

steps

mango 0.6x20

LOT
1
DP
2319

Co
nc

Line
Res
tricti
(6.1 W
on
ide)

48

29.76

TO
P

14

30.85
10.0
0

LOT
48
DP
2320

Je
ru
sa

(3

er Rd
Kaunitoni St

30.87

Fletch

mango 0.4x5

ND
AR
Y F 30
E "
29.99 NCE

.5
3

Rd

26

Wid
e)

uto

IL:15.68

MM

Proposed
Extension

(8.05

27

Stormwater Chamber
LL:15.87
IL:14.51

Concrete
Dish Drain

20
0

Gra
nth
am

30.81

Septic
Tank

SHA
LIM
A

.5
22

Ono St

F 3
0

uto

.5

road center
line

17

LOT
52
DP
2320

edge

55

20

"
'10
38

13

CL
IF

et
ncr

.68
33

25

Co

uto

Building

e
edg Lamp
Post

y
Cit

o
eF

at
otp

PROJECT SITE

.0
0

.5

16.23

uva
oS

of

Gully Pit
LL:15.23

15.87

10

OF

d
r oa

2.06A 6.30
A

nte
ce

7.55

le
TU(Variab
A
R

to

14.54
e
rlin

17446'50"

RA idth)
A
M W

IMPORTANT: Do not scale off this drawing. All dimensions should be checked on site prior to construction.

ID

AMMENDMENTS

DATE

Engineering &
Architectural Consultants

Level 4 Gurbachan Singh Building,


Lot 14 Raojibhai Patel Street, Suva, Fiji Islands.
Ph: +(679) 3100299 Mob: +(679) 7661521

PROJECT

PROPOSED NEW BOUNDARY FENCE


FOR MR. ASHOK PRASAD

LOCATION LOT 53 DP 2330, Suva, Fiji.


CLIENT

Mr. ASHOK PRASAD

TITLE

LOCALITY PLAN

DRAWN BY
CHECKED BY
DATE
DRAWING STATUS
PROJECT NUMBER

TT
AHS
08/17/15
DRAFT
ITS 15-02D

DRAWING NUMBER

A01

LEGEND:
344

C 1 = GATE COLUMN 1

30
00

C 2 = 200MM CMU COLUMN 2

C3
300

C3
300

C3

C3
300

C 3 = STIFFENER COLUMN 3

30
00

103

C3

30
00

WA

LL
5

C3
L6
300

C3
0

C3
300

33
59

C3

IFF

L
WA

300

4
S04

CL

83
336

4
S04

C3

C3
300

33
58
36
52
0
50
00

C2

C3
0

F
C3

WA

300

50
00

C2

000

LL
4

C3
50

0
40

28
70

C3

CO

TO

C3
3000

C3

GARDEN

3000

NC

C2

RE

TE

C3
3000

C3
WAL

3000
L5

200mm CMU
RETAINING WALL

2
S05

C3
3000

EW

LL
3

AY
C1

C1

2
S04

70
7

5000
5682
8

5000

2
S04

C2

L4

C2
5000

SCALE 1 : 200

200mm CMU
RETAINING WALL

C2

63

C2

C2

5000
WAL

3827

5000

11981

WAL

C2

GARDEN

C2

200mm CMU
RETAINING WALL

WALL 1
3827

5000

FENCE PLAN

3827

C2

1
S04
MAIN GATE

7
13

C2
3946

IV

90
01
WA
LL
7

C3
3947

DR

WA

56
87

00

3000

50
00

64

56

C3

C2

64

C3

30

3
324

L2

1
S05

IMPORTANT: Do not scale off this drawing. All dimensions should be checked on site prior to construction.

ID

AMMENDMENTS

DATE

Engineering &
Architectural Consultants

Level 4 Gurbachan Singh Building,


Lot 14 Raojibhai Patel Street, Suva, Fiji Islands.
Ph: +(679) 3100299 Mob: +(679) 7661521

PROJECT

PROPOSED NEW BOUNDARY FENCE


FOR MR. ASHOK PRASAD

LOCATION LOT 53 DP 2330, Suva, Fiji.


CLIENT

Mr. ASHOK PRASAD

TITLE

FENCE PLAN

DRAWN BY
CHECKED BY
DATE
DRAWING STATUS
PROJECT NUMBER

TT
AHS
08/11/15
DRAFT
ITS 15-02D

DRAWING NUMBER

A02

CONCRETE
ARCHITRAVES

3827

3827

CONCRETE
ARCHITRAVES

995
1000

1000

1000

1000

500

200mm CMU
RETAINING WALL

500

600

600

500

500

500

500

500

500

500

500

500

500

500

500

500

500

500

500

500

500

500

500

500

600

600

500

100

2480

800x400mm
CONCRETE PILLAR
(C1)

N.G.L

ELEV. 28.11

1300

50 PVC
WHEEPHOLED
SPACED @ 1000
STAGGERED

WF 1

WF 1
PF 1

SHEAR KEY (SEE DETAILS)

50 PVC WHEEPHOLES
SPACED @ 1000 STAGGERED

PF 1

SHEAR KEY (SEE DETAILS)

WALL 1 ELEV.
SCALE 1 : 75

40x40x3mm SHS
GALV. PIPE FRAME
CONCRETE ARCHITRAVES

MAIN GATE ELEV.


SCALE 1 : 75

5000

CONCRETE
ARCHITRAVES

200mm CMU
COLUMN

20x20x2mm SHS GALV.


PIPE@ 120 crs. MAX

4480

1000

1600

1000

4480

1000

3129

1000

300

1000

600

1000

300 300

1000

1
S06

ELEV. 30.59

200mm CMU
RETAINING
WALL

800x400mm
CONCRETE
PILLAR (C1)

2000

N.G.L
1000

ELEV. 28.11

CONCRETE
ARCHITRAVES

STEEL GATE
(SEE DET.)

200mm CMU
COLUMN

ELEV. 30.59

GATE LAMP

CONCRETE
ARCHITRAVES

20x20x2mm SHS GALV.


PIPE@ 120 crs. MAX

600

2000

3800
3000

40x40x3mm SHS
GALV. PIPE FRAME

20x20x2mm SHS GALV.


PIPE@ 120 crs. MAX

ELEV. 32.59

6080

CONCRETE
ARCHITRAVES

ELEV. 32.59

200mm CMU
COLUMN
1000

1000

500
4483

ELEV. 30.59
NATURAL GROUND
LEVEL (N.G.L)

50 PVC WHEEPHOLES
SPACED @ 1000 STAGGERED
ELEV. 29.70

600

600

WF 2

ELEV. 28.98

ELEV. 28.11
ELEV. 27.60

1000

600

ELEV. 28.63
2400

200mm CMU
RETAINING WALL

ELEV. 29.25

600

ELEV. 27.11

WALL 2 ELEV.

WF 1

WF 1

SHEAR KEY (SEE DETAILS)


SHEAR KEY (SEE DETAILS)
3200

1800

SCALE 1 : 75

IMPORTANT: Do not scale off this drawing. All dimensions should be checked on site prior to construction.

ID

AMMENDMENTS

DATE

Engineering &
Architectural Consultants

Level 4 Gurbachan Singh Building,


Lot 14 Raojibhai Patel Street, Suva, Fiji Islands.
Ph: +(679) 3100299 Mob: +(679) 7661521

PROJECT

PROPOSED NEW BOUNDARY FENCE


FOR MR. ASHOK PRASAD

LOCATION LOT 53 DP 2330, Suva, Fiji.


CLIENT

Mr. ASHOK PRASAD

TITLE

ELEVATIONS

DRAWN BY
CHECKED BY
DATE
DRAWING STATUS
PROJECT NUMBER

TT
AHS
08/12/15
DRAFT
ITS 15-02D

DRAWING NUMBER

A03

5687

GATE LAMP

40x40x3mm SHS
GALV. PIPE FRAME

ELEV. 32.81
ELEV. 32.59

CONCRETE
ARCHITRAVES

200mm CMU
COLUMN
20x20x2mm SHS GALV.
PIPE@ 120 crs. MAX

CONCRETE
ARCHITRAVES
800x400mm CONCRETE
COLUMN (C1)

600

ELEV. 29.99

WF 2

250

200mm CMU
WALL FENCE

850

NATURAL GROUND
LEVEL (N.G.L)

ELEV. 30.81

5780

ELEV. 29.76

1876

ELEV. 28.98

250

WF 2
ELEV. 27.60
964

664

1000

300

ELEV. 28.63

2126

ELEV. 29.25

300

PF 1

300

ELEV. 27.11

WALL 3 ELEV.
SCALE 1 : 50

5000

40x40x3mm SHS
GALV. PIPE FRAME

200mm CMU
COLUMN

20x20x2mm SHS GALV.


PIPE@ 120 crs. MAX

CONCRETE
ARCHITRAVES

200mm CMU
COLUMN

20x20x2mm SHS GALV.


PIPE@ 120 crs. MAX

600

2000

1400

ELEV. 32.59

CONCRETE
ARCHITRAVES

600

N.G.L

250

850

ELEV. 30.59

WF 2

WF 2

200mm
CMU WALL

WALL 4 ELEV.
SCALE 1 : 50

IMPORTANT: Do not scale off this drawing. All dimensions should be checked on site prior to construction.

ID

AMMENDMENTS

DATE

Engineering &
Architectural Consultants

Level 4 Gurbachan Singh Building,


Lot 14 Raojibhai Patel Street, Suva, Fiji Islands.
Ph: +(679) 3100299 Mob: +(679) 7661521

PROJECT

PROPOSED NEW BOUNDARY FENCE


FOR MR. ASHOK PRASAD

LOCATION LOT 53 DP 2330, Suva, Fiji.


CLIENT

Mr. ASHOK PRASAD

TITLE

ELEVATION

DRAWN BY
CHECKED BY
DATE
DRAWING STATUS
PROJECT NUMBER

TT
AHS
08/13/15
DRAFT
ITS 15-02D

DRAWING NUMBER

A04

200mm CMU
WALL FENCE
C3

200mm CMU
WALL FENCE

C3

2000

2000

C3

1400

WF 2

3000

SF 1
1093
1593

WF 2

SCALE 1 : 100

1400

1169

ELEV. 17.50

WALL 5 ELEV.

500

C3

3000

1000

1206

1400

ELEV. 20.00

500

1280
1780

3000

SF 1

C3

200mm CMU
WALL FENCE

1052

500

1185

WF 2

200mm CMU
WALL FENCE

500

552
563
1190
1187

SF 1

1688

3000

1400

WF 2

C3

ELEV. 22.50

500

200mm CMU
WALL FENCE

1063

SF 1

C3

NATURAL
GROUND LEVEL

1087

3000

1400

WF 2

ELEV. 27.50

SF 1

SF 1

200mm CMU
WALL FENCE

ELEV. 25.00

WF 2

1400

C3

300

1400

3000

ELEV. 30.00

700

200mm CMU
WALL FENCE

NATURAL GROUND LEVEL OF BUILDING

WF 2

800
200

1000

ELEV. 15.00

500

1114
1614

SF 1

SF 1

IMPORTANT: Do not scale off this drawing. All dimensions should be checked on site prior to construction.

ID

AMMENDMENTS

DATE

Engineering &
Architectural Consultants

Level 4 Gurbachan Singh Building,


Lot 14 Raojibhai Patel Street, Suva, Fiji Islands.
Ph: +(679) 3100299 Mob: +(679) 7661521

PROJECT

PROPOSED NEW BOUNDARY FENCE


FOR MR. ASHOK PRASAD

LOCATION LOT 53 DP 2330, Suva, Fiji.


CLIENT

Mr. ASHOK PRASAD

TITLE

ELEVATIONS

DRAWN BY
CHECKED BY
DATE
DRAWING STATUS
PROJECT NUMBER

TT
AHS
08/12/15
DRAFT
ITS 15-02D

DRAWING NUMBER

A05

200mm CMU
WALL FENCE

200mm CMU
WALL FENCE

C3

200mm CMU
WALL FENCE

C3

200mm CMU
WALL FENCE

C3

C3

200mm CMU
WALL FENCE

3000

3000

ELEV. 18.00

ELEV. 15.00

N.G.L

250

WF 2

WF 2

WF 2

WF 2

WF 2

250

800

300

N.G.L

200

SF 1

SF 1

SF 1

SF 1

WALL 6 ELEV.
SCALE 1 : 50

2000

GATE LAMP

800x400mm
CONCRETE
COLUMN

50 PVC WHEEPHOLES
SPACED @ 1000 STAGGERED
500

1000

1000

NATURAL GROUND
LEVEL (N.G.L)
1000

1000

1000

200mm CMU
RETAINING WALL
1000

1000

ELEV. 30.59

600

ELEV. 29.70

600

ELEV. 28.63

3780

ELEV. 28.98

600

2966

2480

ELEV. 29.25

300

WF 1

WF 1

300

214

1000

700

ELEV. 28.11

PF 1

SHEAR KEY
(SEE DETAILS)

WALL 7 ELEV.
SCALE 1 : 50
IMPORTANT: Do not scale off this drawing. All dimensions should be checked on site prior to construction.

ID

AMMENDMENTS

DATE

Engineering &
Architectural Consultants

Level 4 Gurbachan Singh Building,


Lot 14 Raojibhai Patel Street, Suva, Fiji Islands.
Ph: +(679) 3100299 Mob: +(679) 7661521

PROJECT

PROPOSED NEW BOUNDARY FENCE


FOR MR. ASHOK PRASAD

LOCATION LOT 53 DP 2330, Suva, Fiji.


CLIENT

Mr. ASHOK PRASAD

TITLE

ELEVATIONS

DRAWN BY
CHECKED BY
DATE
DRAWING STATUS
PROJECT NUMBER

TT
AHS
08/12/15
DRAFT
ITS 15-02D

DRAWING NUMBER

A06

STRUCTURAL NOTES
GENERAL
1.
THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ALL ARCHITECTURAL AND OTHER
CONSULTANTS' DRAWINGS AND SPECIFICATIONS AND WITH SUCH OTHER WRITTEN INSTRUCTIONS AS MAY BE
ISSUED DURING THE COURSE OF THE CONTRACT. ANY DISCREPANCIES SHALL BE REFERRED TO THE
CONTRACT MANAGER BEFORE PROCEEDING WITH THE WORK.

CONCRETE
1.
ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH
AS2870 & AS3600 AND THE CONCRETE SPECIFICATION.
2.
CONCRETE QUALITY.

ELEMENT

3.
SETTING-OUT DIMENSIONS AND SIZES OF STRUCTURAL MEMBERS SHALL NOT BE OBTAINED BY SCALING
THE STRUCTURAL DRAWINGS. ANY SETTING-OUT DIMENSIONS SHOWN IN THE STRUCTURAL DRAWINGS
SHALL BE CHECKED BY THE CONTRACTOR BEFORE CONSTRUCTION COMMENCES. ANY DISCREPANCIES IN
THE DOCUMENTS MUST BE RESOLVED BEFORE ORDERING OR PLACING ANY MATERIALS.

1.

ALL WORKMANSHIP AND MATERIALS SHALL COMPLY WITH AS 3700

30

2.

ALL BLOCKS SHALL BE STRENGTH GRADE 10 MPa.

10

17

20

30

3.
ALL MORTAR SHALL CONSIST OF PORTLAND CEMENT, HYDRATED LIME AND SAND IN THE
PROPORTIONS OF 1:0.25:3 BY VOLUME RESPECTIVELY.

20

25

SLUMP

MAX SIZE AGG

ALL (U.N.O)

80

20

BLOCK FILL

200

COLUMNS

100

FOOTINGS

80

CONCRETE GRADE(MPa)

4.
DURING CONSTRUCTION THE STRUCTURE SHALL BE MAINTAINED IN A SAFE AND STABLE CONDITION
AND NO PART SHALL BE OVERSTRESSED. TEMPORARY BRACING SHALL BE PROVIDED BY THE CONTRACTOR
AS REQUIRED TO KEEP THE WORKS AND EXCAVATIONS STABLE AT ALL TIMES.
UNLESS NOTED OTHERWISE ALL LEVELS ARE IN METRES AND ALL DIMENSIONS ARE IN MILLIMETRES.

FORMWORK
1.
THE DESIGN CERTIFICATION, CONSTRUCTION AND PERFORMANCE OF THE FORMWORK AND FALSE
WORK IS THE RESPONSIBILITY OF THE CONTRACTOR.
2.
DESIGN AND CONSTRUCTION AND STRIPPING TIMES TO COMPLY WITH AS 3610 AND AS 3600 UNLESS
OTHERWISE APPROVED BY THE CONTRACT MANAGER.
3.

FOR FINISH TO FORMED CONCRETE SURFACES REFER TO SPECIFICATION.

SAFE BEARING CAPACITIES: STRIP FOOTINGS 100 kPa PAD FOOTINGS 100 kPa

NO ADMIXTURES SHALL BE USED IN CONCRETE UNLESS APPROVED IN WRITING.

6.
MINIMUM CLEAR COVER TO REINFORCEMENT TO BE 50mm MIN TO TIES IN EXPOSED
FACES OF BEAMS AND COLUMNS.

EXTERNAL

7.
ALL REINFORCEMENT SHALL BE FIRMLY SUPPORTED ON PLASTIC CHAIRS AT NOT GREATER THAN 1
METRE CENTRES BOTH WAYS, BARS SHALL BE TIED AT ALTERNATE INTERSECTIONS.
8.

10. CONSTRUCTION JOINTS WHERE NOT SHOWN SHALL BE LOCATED TO THE APPROVAL OF THE
CONTRACT MANAGER.
11. THE FINISHED CONCRETE SHALL BE A DENSE HOMOGENEOUS MASS, COMPLETELY FILLING
THE FORMWORK THOROUGHLY EMBEDDING THE REINFORCEMENT AND FREE OF STONE POCKETS.
ALL CONCRETE SHALL BE COMPACTED WITH MECHANICAL VIBRATORS.
12. CURING OF ALL CONCRETE SHALL BE ACHIEVED BY KEEPING SURFACES CONTINUOUSLY WET
FOR A PERIOD OF 3 DAYS, AND PREVENTION OF LOSS OF MOISTURE FOR A TOTAL OF 7 DAYS
FOLLOWED BY A GRADUAL DRYING OUT. APPROVED SPRAYED ON CURING COMPOUNDS MAY
BE USED WHERE NO FLOOR FINISHES ARE PROPOSED. POLYTHENE SHEETING OR WET HESSIAN MAY
BE USED IF PROTECTED FROM WIND AND TRAFFIC.

6.
ALL CORES ARE TO BE FILLED WITH 20 MPa CONCRETE (10 mm AGGREGATE SIZE, MAXIMUM
SLUMP 200).
7.

PROVIDE CLEAN OUT HOLES AT BOTTOM OF ALL FILLED CORES.

8.
PROVIDE 65 mm COVER FROM THE OUTSIDE OF THE BLOCKWORK TO ALLOW ADEQUATE
GROUT COVER TO REINFORCEMENT.
9.
PROVIDE VERTICAL JOINTS IN BLOCKWORK AT MAX 10 METRE CENTRES UNLESS NOTED
OTHERWISE (UNO).
10.

BLOCKWORK SHALL COMPLY WITH AS 3700

11.

ALL GROUT SHALL BE S17/10

CONSTRUCTION NOTES

4. BACKFILL OVER FOOTINGS SHALL BE APPROVED GRANULAR MATERIAL COMPACTED IN LAYERS OF 150
mm MAXIMUM TO AT LEAST 90% OF THE MAXIMUM DRY DENSITY IN ACCORDANCE WITH AS 1289.
PROJECT CONTROL TESTING SHALL BE CARRIED OUT IN ACCORDANCE WITH AS 3600.
5.

5.
JOINT THICKNESS SHALL BE MINIMUM 6 mm AND MAXIMUM 12 mm. FACE SHELLS AND
PERPENDS SHALL BE FULLY BEDDED IN MORTAR.

THE LEVELS SHOWN ON THE DRAWINGS ARE FOR PRICING PURPOSES ONLY.

2. ACTUAL FOOTINGS SHALL BE BASED ON A MATERIAL HAVING A SAFE BEARING CAPACITY AS LISTED IN
THE TABLE BELOW UNLESS OTHERWISE NOTED, AND SHALL BE INSPECTED BY THE CONTRACT MANAGER
BEFORE CONCRETE IS PLACED.
3.

4.
CHASES AND HOLES SHALL NOT BE MADE IN BLOCKWORK WITHOUT THE APPROVAL OF THE
CONTRACT MANAGER.

13. THE CONTRACT MANAGER SHALL BE GIVEN A MINIMUM OF 24 HOURS NOTICE FOR
REINFORCEMENT INSPECTION AND CONCRETE SHALL NOT BE DELIVERED UNTIL FINAL
APPROVAL IS OBTAINED.

FOUNDATIONS
1.

LAP LENGTHS FOR STARTER BARS IS TO BE 600mm.

REINFORCED BLOCKWORK

2.
ALL MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE RELEVANT AND CURRENT
A.S. CODES AND WITH THE BY-LAWS AND ORDINANCES OF THE RELEVANT BUILDING AUTHORITIES EXCEPT
WHERE VARIED BY THE PROJECT SPECIFICATION.

5.

21.

CONCRETE DIMENSIONS SHOWN DO NOT INCLUDE THICKNESSES OF APPLIED FINISHES.

9.
NO HOLES, CHASES OR EMBEDMENT OF PIPES OTHER THAN THOSE SHOWN ON THE
STRUCTURAL
DRAWINGS SHALL BE MADE IN CONCRETE MEMBERS WITHOUT THE PRIOR
WRITTEN APPROVAL OF THE
CONTRACT MANAGER.

14.

REINFORCEMENT SYMBOLS:
3-D12
3 (NUMBER OF BARS IN GROUP)
D (BAR GRADE AND TYPE)
12 (NOMINAL BAR SIZE IN MM)

D12-250
D (BAR GRADE AND TYPE)
12 ( NOMINAL BAR SIZE IN MM)
250 (SPACING IN MM)

15. REINFORCEMENT IS REPRESENTED DIAGRAMMATICALLY AND NOT NECESSARILY IN TRUE


PROJECTION.
16. SPLICES IN REINFORCEMENT SHALL BE MADE ONLY IN POSITION SHOWN OR OTHERWISE
APPROVED IN WRITING BY THE CONTRACT MANAGER.
17. WELDING OF REINFORCEMENT SHALL NOT BE PERMITTED UNLESS SHOWN ON THE
STRUCTURAL DRAWINGS OR APPROVED BY THE CONTRACT MANAGER.
18. JOGGLES TO BARS SHALL BE 1 BAR DIAMETER OVER A LENGTH OF 12 BAR DIAMETERS UNLESS
NOTED OTHERWISE.
19. CONCRETE BELOW GROUND IN WALLS, BEAMS, OR PEDESTALS SHALL BE PLACED INTO
PROPERLY CONSTRUCTED FORMS. IF APPROVED BY THE CONTRACT MANAGER, CONCRETE MAY
BE PLACED AGAINST AN EARTH FACE BUT THE CONCRETE DIMENSIONS SHOWN ON THE DRAWINGS
SHALL BE INCREASED TO PROVIDE 20mm ADDITIONAL COVER TO THE REINFORCEMENT ADJACENT
THE EARTH FACE.
20. A BOND BREAKING MATERIAL SHALL BE PLACED BETWEEN CONTACTING SURFACES AT
CONTRACTION JOINTS. REINFORCEMENT SHALL NOT BE CONTINUOUS THROUGH
CONTRACTION JOINTS.

1. ALL CONSTRUCTION SHALL COMFORM TO:


1.1 SPECIFICATION
1.2 CONDITIONS OF THE CONTRACT
1.3 AS PROVISIONS

2. THE SETTING OUT AND ELEVATION OF THE STRUCTURE SHALL BE


APPROVED BY THE CONTRACT MANAGER PRIOR TO THE START OF ANY
CONSTRUCTION WORK
3. THE CONTRACTOR SHALL VERIFY THE BOUNDARIES OF THE STRUCTURE.
HE SHALL PROVIDE AREAS THAT REQUIRES HIS OWN USE. IT IS THE
INTENTION OF THE PLANS TO UNDISTURBED EVERYTHING ON THE
UNFINISHED WORK. ALL DISTURBED AREAS BY CONSTRUCTION SHALL BE
RESTORED TO ITS ORIGINAL CONDITION AS DIRECTED BY THE CONTRACT MANAGER
4. ALL EXISTING STRUCTURE AND OBSTRUCTION WHICH WILL INTERFERE
THE WORK SHALL BE COMPLETELY REMOVED AND DISPOSED OFF
FROM THE SITE.
5. ALL SALVAGEABLE MATERIALS SHALL BE PROPERLY AND CAREFULLY
DISMANTLED AND DEPOSITED ON A CONVENIENT SITE AS INSTRUCTED
BY THE CONTRACT MANAGER.

IMPORTANT: Do not scale off this drawing. All dimensions should be checked on site prior to construction.

ID

AMMENDMENTS

DATE

Engineering &
Architectural Consultants

Level 4 Gurbachan Singh Building,


Lot 14 Raojibhai Patel Street, Suva, Fiji Islands.
Ph: +(679) 3100299 Mob: +(679) 7661521

PROJECT

PROPOSED NEW BOUNDARY FENCE


FOR MR. ASHOK PRASAD

LOCATION LOT 53 DP 2330, Suva, Fiji.


CLIENT

Mr. ASHOK PRASAD

TITLE

STRUCTURAL NOTES

DRAWN BY
CHECKED BY
DATE
DRAWING STATUS
PROJECT NUMBER

TT
AHS
08/17/15
DRAFT
ITS 15-02D

DRAWING NUMBER

S01

LEGEND:
343

IFF
CL

36
01
3

1
SF

2
S03

6
S03

W
F2

18
85
8

1
SF

1
SF

1
SF

W
F2

18

SF1
WF
2

6
S03

SF1

WF
2

90
26

SF1
WF
2

3000

3000

SF1
WF
2

47
96

W
F1

SF1

83
25

WF
2
WF
2

3000

SF1

7
13

3947

WF
2

6
S03

3
S04

5670
5

SCALE 1 : 200

63

2944
6

12234

WF
2

WF 1

FOUNDATION PLAN

1
S03

850

3000

W
F2

PF
1

3000

TO

3000

00

SF1
WF
2

PF
1

1
SF

1
SF

SF1

1
SF

56

F2
W

F2
W

2
300

33
59

F
W

F2
W

0
300

1
SF

1
SF

F2
W

0
300

F2
W

F
W

F2
W

0
300
0
300

6
S03

1
SF

WF 2 = WALL FOOTING 2
30
00

103
1
SF

300

F2
W

WF 1 = WALL FOOTING 1

34

1
SF

SF 1 = STIFFENER COLUMN FOOTING


30
00

F
W

334

F2
W

1
SF

1
SF

F2
W

0
300
0
300

SF1

300

F2
W

F2
W

PF 1 = GATE COLUMN PAD FOOTING

F
W

0
300

30
00

2391

1800

WF 1

3
WF
1
S04
5312

IMPORTANT: Do not scale off this drawing. All dimensions should be checked on site prior to construction.

ID

AMMENDMENTS

DATE

Engineering &
Architectural Consultants

Level 4 Gurbachan Singh Building,


Lot 14 Raojibhai Patel Street, Suva, Fiji Islands.
Ph: +(679) 3100299 Mob: +(679) 7661521

PROJECT

PROPOSED NEW BOUNDARY FENCE


FOR MR. ASHOK PRASAD

LOCATION LOT 53 DP 2330, Suva, Fiji.


CLIENT

Mr. ASHOK PRASAD

TITLE

FOUNDATION PLAN

DRAWN BY
CHECKED BY
DATE
DRAWING STATUS
PROJECT NUMBER

TT
AHS
08/12/15
DRAFT
ITS 15-02D

DRAWING NUMBER

S02

1600
800

325

900

75

75

225

300

225

75

250

75
200

900

91

218

91

400

300x200mm RC
COLUMN (C3)
900x900x200mm RC
PAD FOOTING (PF2)

D10 STIRRUPS
@ 200 crs.

D12 TRANSVERSE
BAR @ 350mm crs.

75

4
S03

275

3
S03

525

4-D12
VERTICAL BARS

75

525

1600x1600x300mm RC
PAD FOOTING (PF1)

400

1600

275

6-D12 BOTHWAYS

800x400mm RC
COLUMN (C1)

3-D12 LONGITUDINAL
BARS @ 125mm crs.

175

325

75

75

WF 2 DET.

6 S03

SCALE 1 : 10

D10 STIRRUPS
@ 200 crs.

12-D16 BOTHWAYS

SF 1 PLAN

1 S02

SCALE 1 : 20

75

D10 VERTICAL BARS @


300mm crs. MAX.
N.G.L

SCALE 1 : 20

300

800
40

720

40

40

220

40

D10 STIRRUPS
@ 200 crs.

N.G.L

N.G.L

1000

D10 STIRRUPS
@ 200 crs.
D12 VERTICAL
BARS

D16 VERTICAL
BARS

200 CMU WALL


FULLY GROUTED

300x200mm RC
COLUMN (C3)

3-D12 LONGITUDINAL
BARS @ 125mm crs.

900x900x200mm RC
PAD FOOTING (PF2)

D12 TRANSVERSE
BAR @ 350mm crs.

75

1600x1600x300mm RC
PAD FOOTING (PF1)

5
S03
175

D10 @ 100 crs.

800x400mm RC
COLUMN (C1)

VARIES

D10 @ 100 crs.

1000MM HEIGHT

D10 HORIZONTAL BARS


@ 400mm crs. MAX.

750

1 S02

10-D16
VERTICAL BARS

PF 1 PLAN

250

6-D12 BOTHWAYS

200

300

12-D16 BOTHWAYS

91

218

91

400
93

1439

93

93

714

3
1 S03

93

900

1625

PF 1 SECTION

2 S03

SCALE 1 : 20

SF 1 SECTION

1 S02

TYP. WALL 3,4,5,6 SECTION DET.


SCALE 1 : 10

SCALE 1 : 20
IMPORTANT: Do not scale off this drawing. All dimensions should be checked on site prior to construction.

ID

AMMENDMENTS

DATE

Engineering &
Architectural Consultants

Level 4 Gurbachan Singh Building,


Lot 14 Raojibhai Patel Street, Suva, Fiji Islands.
Ph: +(679) 3100299 Mob: +(679) 7661521

PROJECT

PROPOSED NEW BOUNDARY FENCE


FOR MR. ASHOK PRASAD

LOCATION LOT 53 DP 2330, Suva, Fiji.


CLIENT

Mr. ASHOK PRASAD

TITLE

FOOTING DETAILS

DRAWN BY
CHECKED BY
DATE
DRAWING STATUS
PROJECT NUMBER

TT
AHS
08/13/15
DRAFT
ITS 15-02D

DRAWING NUMBER

S03

3
S05

800
688

NATURAL GROUND LEVEL OF BUILDING

56

ELEV. 30.59

300

56

56

4-D12 TIES WITH R10


STIRRUPS @ 300 crs.

800x400mm RC
COLUMN (C1)
288

400

INFILL MATERIALS
50 PVC WHEEPHOLES
SPACED @ 1000
STAGGERED

56

D10 STIRRUPS
@ 200 crs.

GEOFABRIC
SEPARATION
LAYER

SCALE 1 : 10

200

200

600

1000
100

200mm CMU
WALL FENCE

VARIES

1 A02

C1 PLAN

D12 VERTICAL BARS


@ 300 crs MAX.

600

10-D16
VERTICAL BARS

200

200

100

D12 HORIZONTAL
BAR @ 200 crs MAX.

190

3
S07

D12 HORIZONTAL
BAR @ 400 crs.

C2 PLAN (TYP.)

1 A02

SCALE 1 : 10

200mm CMU
FULLY GROUTED
COLUMN

600

D12 VERTICAL BAR

EXISTING NATURAL
GROUND LEVEL

INFILL MATERIALS

ELEV. 28.11
100mm CRUSHED
ROCK DRAINAGE
FILL MATERIALS

200

300
57

1300

D16 @ 300 crs.

186

57

58

200

D16 @ 275 crs.

300

84

4
1 A02

350

D16 HORIZONTAL BAR

D16 @ 275 crs.

300

4-D12
VERTICAL BARS

600

300x200mm RC
COLUMN (C3)

58

200

D10 STIRRUPS @ 300 crs.

WF 1
D16 @ 300 crs.

C3 PLAN

SHEAR KEY DETAIL

300

SCALE 1 : 10

1500
1800

TYP. WALL 1,2,7 RETAINING WALL DETAILS (WF 1)

1 S02

SCALE 1 : 20
IMPORTANT: Do not scale off this drawing. All dimensions should be checked on site prior to construction.

ID

AMMENDMENTS

DATE

Engineering &
Architectural Consultants

Level 4 Gurbachan Singh Building,


Lot 14 Raojibhai Patel Street, Suva, Fiji Islands.
Ph: +(679) 3100299 Mob: +(679) 7661521

PROJECT

PROPOSED NEW BOUNDARY FENCE


FOR MR. ASHOK PRASAD

LOCATION LOT 53 DP 2330, Suva, Fiji.


CLIENT

Mr. ASHOK PRASAD

TITLE

COLUMN & RETAINING DETAILS

DRAWN BY
CHECKED BY
DATE
DRAWING STATUS
PROJECT NUMBER

TT
AHS
08/13/15
DRAFT
ITS 15-02D

DRAWING NUMBER

S04

D12 HORIZONTAL
BAR (SEE DET.)

D12 VERTICAL
BAR (SEE DET.)

RC COLUMN
OR WALL

200mm CMU FULLY


GROUTED COLUMN

12mm THK. EXPANSION


JOINT WITH MASTIC FILLER
OR EQUIVALENT

D12 VERTICAL
BAR

D12 HORIZONTAL
BAR @ 400 crs.

400MM LAP

DOWEL BAR TO
MATCH CMU BLOCK
REINFORCEMENT

12mm THK. EXPANSION


JOINT WITH MASTIC FILLER
OR EQUIVALENT

200mm CMU
FULLY GROUTED
COLUMN

400MM LAP

2
1 A02

D12 VERTICAL
BAR (SEE DET.)

INTERSECTION COLUMN OR WALL


SCALE 1 : 10

200mm CMU FULLY


GROUTED COLUMN

D12 HORIZONTAL
BAR (SEE DET.)

NATURAL GROUND
LEVEL OF BUILDING

ELEV. 30.59

1
1 A02

300

200mm CMU WALL

CORNER WALL DET.


SCALE 1 : 10

4-D12 TIES WITH R10


STIRRUPS @ 300 crs.

3
3 S04

BOND BEAM DETAILS


SCALE 1 : 10

IMPORTANT: Do not scale off this drawing. All dimensions should be checked on site prior to construction.

ID

AMMENDMENTS

DATE

Engineering &
Architectural Consultants

Level 4 Gurbachan Singh Building,


Lot 14 Raojibhai Patel Street, Suva, Fiji Islands.
Ph: +(679) 3100299 Mob: +(679) 7661521

PROJECT

PROPOSED NEW BOUNDARY FENCE


FOR MR. ASHOK PRASAD

LOCATION LOT 53 DP 2330, Suva, Fiji.


CLIENT

Mr. ASHOK PRASAD

TITLE

TYP. WALL DETAILS

DRAWN BY
CHECKED BY
DATE
DRAWING STATUS
PROJECT NUMBER

TT
AHS
08/28/15
DRAFT
ITS 15-02D

DRAWING NUMBER

S05

2859
1425

1425

800x400mm GATE PILLAR

100

SPECIAL MADE GATE HINGES: M24


GALV. BOLT CAST IN CONC. POST AS
SHOWN SLOTTED INTO 25x100mm
LONG GALV. PIPE WELDED TO GATE
WITH 10mm FMG PLATE SPACER

282

371

50x5mm
CHS GALV.
PIPE

1100

523

50x5mm
CHS GALV.
PIPE

1100

857

20x2mm CHS
GALV. PIPE

2
S07

1250

857

3289

3500

3600

20x2mm
CHS GALV.
PIPE

1250

50x5mm CHS
HORIZONTAL
GALV. PIPE

500

498

892

50x5mm CHS
HORIZONTAL
GALV. PIPE

100

100

N.G.L

GATE ELEV.

SCALE 1 : 20

3 A03

TYP. GATE HINGE DETAIL


SCALE 1 : 20

IMPORTANT: Do not scale off this drawing. All dimensions should be checked on site prior to construction.

ID

AMMENDMENTS

DATE

Engineering &
Architectural Consultants

Level 4 Gurbachan Singh Building,


Lot 14 Raojibhai Patel Street, Suva, Fiji Islands.
Ph: +(679) 3100299 Mob: +(679) 7661521

PROJECT

PROPOSED NEW BOUNDARY FENCE


FOR MR. ASHOK PRASAD

LOCATION LOT 53 DP 2330, Suva, Fiji.


CLIENT

Mr. ASHOK PRASAD

TITLE

GATE DETAILS

DRAWN BY
CHECKED BY
DATE
DRAWING STATUS
PROJECT NUMBER

TT
AHS
08/20/15
DRAFT
ITS 15-02D

DRAWING NUMBER

S06

20x20x2mm SHS STEEL


PIPE FILLET WELD TO STEEL
FRAME @ 120 crs MAX.

40x40x3mm SHS
STEEL PIPE FRAME

300

VARIES

300
116

160
632

912

40x40x3mm SHS STEEL PIPE


(300mm EMBED INTO CMU
COLUMN)

50 120

632

1117

200mm CMU
COLUMN

300

40x40x3mm SHS STEEL PIPE


(300mm EMBED INTO CMU
COLUMN)

300

50 120

912

200mm CMU
COLUMN

1117

160

205

VARIES

205

116

300

116

VARIES

416

116

300

VARIES

200mm
CMU FENCE

40x40x3mm SHS
STEEL PIPE FRAME

70x100x10mm F.M.S
SPACER PLATE

TYP. FENCE RAILING DETAIL

200mm
CMU WALL

SCALE 1 : 20

50x5mm GALV.
PIPE GATE FRAMING

BURLAP BAG
WITH GRAVEL

800x400mm
GATE PILLAR

6mm THK
FILLET WELD
50 PVC PIPE
WHEEPHOLES SPACED
@ 1000 STAGGERED

25x100mm LONG GALV.


PIPE WELDED TO PLATE

2
1 S06

TYP. GATE HINGE


SCALE 1 : 75

M24 GALV. BOLTCAST IN


POST AND BEND 90 UP
120mm LONG

3
3 S04

WHEEPHOLES DET.
SCALE 1 : 10

IMPORTANT: Do not scale off this drawing. All dimensions should be checked on site prior to construction.

ID

AMMENDMENTS

DATE

Engineering &
Architectural Consultants

Level 4 Gurbachan Singh Building,


Lot 14 Raojibhai Patel Street, Suva, Fiji Islands.
Ph: +(679) 3100299 Mob: +(679) 7661521

PROJECT

PROPOSED NEW BOUNDARY FENCE


FOR MR. ASHOK PRASAD

LOCATION LOT 53 DP 2330, Suva, Fiji.


CLIENT

Mr. ASHOK PRASAD

TITLE

CONSTRUCTION DETAILS

DRAWN BY
CHECKED BY
DATE
DRAWING STATUS
PROJECT NUMBER

TT
AHS
08/20/15
DRAFT
ITS 15-02D

DRAWING NUMBER

S07