MAS Setting

1. Check that the following parameter has correct value:


C:\>phaprint ACS_APCONFBIN_CpAndProtocolType
If the parameter does not exist, it means that the functionality fewer clone
has not been implemented. If so, continue with the next step. In reality, it
should always exist.
If it exists it must have the following value:
1 for APZ 212 3x.
2 for APZ 212 40.
3 for APZ 212 50.
4 for APZ 212 55 and APZ 212 60.
Continue with step 3
2. Check that the following parameter has correct value:
C:\>phaprint MAS_CPTASP_Protocol
It must have the following value:
1 for APZ 212 3x.
2 for APZ 212 40.
3 for APZ 212 50.
4 for APZ 212 55 and APZ 212 60.
3. If the parameter value is faulty, update it by following the OPI APG40, Soft
Function Change, Parameter, Change in reference [13] on page 108. See
also the example in chapter 7.4.5 Set APCONF Parameter on page 92.