Académique Documents
Professionnel Documents
Culture Documents
ProCash 8050
Installation Guide
01750177940 C
CINEO C2550
ProCash 8050
Installation Guide
01750177940 C
Contents
Introduction ...............................................................................................
Symbols used in this manual ......................................................................
Important safety precautions ......................................................................
Installation note ......................................................................................
General safety precautions ....................................................................
1
2
2
2
3
Contents
31
34
35
35
36
36
37
37
38
38
41
42
42
44
44
44
45
46
47
47
48
48
51
52
53
53
54
55
59
61
63
65
65
66
66
67
68
69
69
70
71
01750177940 C
Contents
71
72
73
73
75
75
76
77
78
83
Installation ............................................................................................... 87
Removing the transport packing ............................................................... 87
Removing the shipping crate .................................................................... 88
General information ............................................................................. 88
Disassembly ........................................................................................ 89
Mounting sets............................................................................................ 90
Mounting set 01750006706 for installation frame or installation
rack with UL safe ................................................................................. 90
Mounting set 01750051579 for installation frames or installation
racks with CEN L4 / CEN III / CEN IV safe .......................................... 91
Mounting set 01750078516 safe (for UL safe) on 25 mm (0.98")
installation frame.................................................................................. 92
Mounting set 01750051578 (for CEN L4 / CEN III / CEN IV safe)
on 25 mm (0.98") installation frame ..................................................... 92
Mounting set 01750051060 for safe on 82 mm (3.23") and 222
mm (8.74") installation frame or installation rack ................................. 92
Overview of installation types ................................................................... 93
Installation with 25 mm (0.98") installation frame ..................................... 94
Installing the installation frame ............................................................ 94
Mounting the device on the installation frame ................................... 102
Moving the Cash media dispenser (CMD) upwards ..................... 102
Screwing the device on the installation frame .............................. 103
Pushing the Cash Media Dispenser (CMD) down ........................ 104
Installing the power and data cables in the device ....................... 104
Further procedure for CEN installation ......................................... 105
General information ...................................................................... 105
Installation with 82 mm (3.23") installation frame ................................... 106
Installing the installation frame .......................................................... 106
Mounting the device on the installation frame ................................... 113
Moving the Cash media dispenser (CMD) upwards ..................... 113
Screwing the device on the installation frame .............................. 114
01750177940 C
III
Contents
115
115
116
116
117
117
124
124
125
126
126
127
127
128
128
128
129
130
130
137
141
141
142
143
143
144
144
145
146
148
150
152
153
155
156
156
157
01750177940 C
Contents
Installation..........................................................................................
Connection to the relay panel for external features ...........................
Remote status indicator - audio ..............................................................
Delivery package ...............................................................................
Installation..........................................................................................
Connection to the relay panel for external features ...........................
Shortening the cables .............................................................................
Adapting the cable length at the relay panel end ...............................
Adapting the cable length at the standard remote status indicator
end .....................................................................................................
Adapting the cable length at the remote status indicator (audio) ......
162
163
165
165
166
168
170
170
Appendix................................................................................................
Check list for installation preparations for self-service systems .............
General information ...........................................................................
Preparations ......................................................................................
Construction work .........................................................................
Power and data cables .................................................................
Organizational preparations..........................................................
Delivery and installation ................................................................
Flooring materials on the path of transport ...................................
Notes concerning installation preparation..........................................
Technical Data ........................................................................................
General Installation Conditions ..........................................................
Electrical characteristics of the supply network ............................
Device Conditions .........................................................................
Installation specifications ..............................................................
Environmental Conditions .............................................................
Compliance with Standards and Certifications .......................................
Standards met ...................................................................................
Conformity .........................................................................................
Notes concerning radio interference suppression and electrical
safety .................................................................................................
Certification for data transmission .....................................................
FCC rules and Canadian Standard ICES - 003 .................................
UL 291, Level 1 (security Container) .................................................
Environmental protection ........................................................................
Environmentally and recycling-friendly product development ............
Saving energy ....................................................................................
Disposing of used consumables ........................................................
Labels on plastic case parts ..............................................................
Returning, recycling and disposing of used units and
177
177
178
178
178
179
179
180
180
181
183
183
183
184
186
188
190
190
190
01750177940 C
170
173
191
191
191
191
192
192
192
192
193
Contents
VI
01750177940 C
Abbreviations
EEC
European Economic
Community
EMA
EMC
Electromagnetic
Compatibility
EN
European standard
Communaut Europenne
(European Community)
Declaration of Conformity
EPP
CEE
Certification of Electrical
Equipment
FCC
CEN
Comit Europen de
Normalisation (European
Committee for
Standardization)
BSMI
Bureau of Standards,
Metrology and Inspection
C
CE
F
Federal Communications
Commission
G
GmbH Limited liability company
CFR
Code of Federal
Regulation
CIM
ICES
Interference-Causing
Equipment Standards
CNS
Chinese National
Standards
IP
International Protection
CSA
Canadian Standards
Association
ISO
International Organization
for Standardization
D
DIN
DT
Data Transmission
M
MM
E
EC
European Community
EDM
Encryption/Decryption
Module
01750177940 C
VII
Abbreviations
R
RSI
S
SELV
T
TN network
Power supply
network in accordance
with EN 60950
U
UL
Underwriters Laboratories
Inc.
UPS
Uninterruptible Power
Supply
V
VdS
VIII
Association of Property
Insurance Companies
01750177940 C
Introduction
This installation guide provides all the information you require to plan and
prepare installation and to set up the CINEO C2550 (Gas) or the
ProCash 8050 (Gas).
The CINEO C2550 (Gas) is supplied with a CMD V4 / CMD V5 and the
ProCash 8050 (Gas) with a CMD V4. The installation of the CINEO C2550 /
ProCash 8050 (Gas) is largely identical. Differences in the procedure for the
various systems will be pointed out.
The CINEO C2550 / ProCash 8050 (Gas) is available in the following versions:
CINEO C2550 / ProCash 8050 with 41 mm (1.61") tunnel in
safe construction types UL / CEN L4 / CEN III / CEN IV:
with 4-cassette dispenser without attached logo case
with 4-cassette dispenser with attached logo case
with 5-cassette dispenser without attached logo case
with 5-cassette dispenser with attached logo case
with 6-cassette dispenser without attached logo case
with 6-cassette dispenser with attached logo case
CINEO C2550 / ProCash 8050 Gas with 41 mm (1.61") tunnel in safe
construction types CEN III / CEN IV:
with 4-cassette dispenser without attached logo case
with 4-cassette dispenser with attached logo case
The following accessories are available:
1.
2.
01750177940 C
Introduction
Installation note
When installing the device and/or doing any work on it, make sure that it is
disconnected from power.
Remove the shipping restraints inside the unit which secure its components
during transportation if necessary for the installation (see enclosed
information sheet).
01750177940 C
Introduction
Introduction
Always keep the device's vents free from obstruction to ensure proper air
circulation and to prevent malfunctions resulting from overheating.
Only use accessories and extension components that have been approved
by us. Nonobservance can result in damage to the device or violations of
regulations concerning safety, radio interference and ergonomical
requirements.
Note that there are only safety extra-low voltage circuits (SELV circuits) if
you want to feed voltage from an external source into prepared cables to
install additional electronics (e. g. EMA connection, relay panel for external
features).
To clean and maintain the device only use cleaning agents approved by
WINCOR NIXDORF International GmbH (see chapter "Appendix" in the
operating manual).
Repairs
Repair work may only be carried out by authorized personnel.
Unauthorized opening of the device or repair work carried out
improperly could result in considerable danger to the user.
In case of noncompliance, WINCOR NIXDORF International GmbH
excludes all liability.
01750177940 C
Introduction
Lithium batteries
The handling and the replacement should only be performed by
authorized service personnel who were trained by the
WINCOR NIXDORF International GmbH.
There is danger of fire or explosion if the batteries are handled
improperly. It is therefore important to note the following points:
Before operating the device, remove all parts inside of it which secure
its components during transportation or check whether they have been
removed (see info sheet supplied with the device).
01750177940 C
Introduction
01750177940 C
From the time of installation to the time the device is put into service,
the climatic environmental conditions for storage must be met (see
chapter "Appendix").
Levels must not fall below or exceed these conditions because
irreparable damage may be caused to the device otherwise.
In the event of non-compliance, WINCOR NIXDORF
International GmbH shall not assume liability for any damage that is
caused to the device.
Device dimensions
i
01750177940 C
Device dimensions
600 (23.62")
72/43*
(2.83"/1.69"*)
1418 (55.83")
583 (22.95")
666 (26.22")
675 (26.57")
1890 (74.41")
1500 (59.06")
885 (34.84")
665 (26.18")
674 (26.54")
215
(8.46")
848 (33.39")
1214 (47.8")
1256 (49.45")
13.5
(0.53")
540
(21.26")
675 (26.57")
01750177940 C
Device dimensions
600 (23.62")
72/43*
(2.83"/1.69"*)
1623 (63.9")
583 (22.95")
669 (26.34")
675 (26.57")
1890 (74.41")
1500 (59.06")
885 (34.84")
665 (26.18")
671 (26.42")
215
(8.46")
848 (33.39")
1214 (47.8")
1256 (49.45")
13.5
(0.53")
540
(21.26")
675 (26.57")
01750177940 C
Device dimensions
640 (25.20")
600 (23.62")
72/43*
(2.83"/1.69"*)
1418 (55.83")
583 (22.95")
666 (26.22")
675 (26.57")
1890 (74.41")
1500 (59.06")
885 (34.84")
665 (26.18")
674 (26.54")
215
(8.46")
848 (33.39")
1214 (47.8")
1256 (49.45")
13.5
(0.53")
540
(21.26")
675 (26.57")
10
01750177940 C
Device dimensions
640 (25.20")
72/43*
(2.83"/1.69"*)
600 (23.62")
1623 (63.9")
583 (22.95")
669 (26.34")
675 (26.57")
1890 (74.41")
1500 (59.06")
885 (34.84")
665 (26.18")
671 (26.42")
215
(8.46")
848 (33.39")
1214 (47.8")
1256 (49.45")
13.5
(0.53")
540
(21.26")
675 (26.57")
01750177940 C
11
Device dimensions
600 (23.62")
72/43*
(2.83"/1.69"*)
1558 (61.34")
723 (28.46")
815 (32.09")
809 (31.85")
2030 (79.92")
1640 (64.57")
1025 (40.35")
665 (26.18")
671 (26.42")
215
(8.46")
848 (33.39")
1214 (47.8")
1256 (49.45")
13.5
(0.53")
540
(21.26")
675 (26.57")
12
01750177940 C
Device dimensions
600 (23.62")
72/43*
(2.83"/1.69"*)
1763 (69.41")
723 (28.46")
815 (32.09")
809 (31.85")
2030 (79.92")
1640 (64.57")
1025 (40.35")
665 (26.18")
671 (26.42")
215
(8.46")
848 (33.39")
1214 (47.8")
1256 (49.45")
13.5
(0.53")
540
(21.26")
675 (26.57")
01750177940 C
13
Device dimensions
600 (23.62")
72/43*
(2.83"/1.69"*)
1678 (66.06")
843 (33.19")
935 (36.81")
929 (36.57")
2150 (84.65")
1760 (69.29")
1145 (45.08")
665 (26.18")
671 (26.42")
215
(8.46")
848 (33.39")
1214 (47.8")
1256 (49.45")
13.5
(0.53")
540
(21.26")
675 (26.57")
14
01750177940 C
Device dimensions
600 (23.62")
72/43*
(2.83"/1.69"*)
1883 (74.13")
843 (33.19")
935 (36.81")
929 (36.57")
2150 (84.65")
1760 (69.29")
1145 (45.08")
665 (26.18")
671 (26.42")
215
(8.46")
848 (33.39")
1214 (47.8")
1256 (49.45")
13.5
(0.53")
540
(21.26")
675 (26.57")
01750177940 C
15
Installation options
Installation options
The CINEO C2550 / ProCash 8050 (Gas) can only be installed through a wall
opening.
The following table shows the installation options for the device versions
depending on the floor heights on the customer panel side and on the device
side.
CINEO C2550 / ProCash 8050 (Gas) with
4-cassette dispenser
Installation with 25 mm (0.98") installation
frame on a base
Installation with 222 mm (8.74") installation
frame
Installation with height-adjustable installation
rack
Same
floor height
yes
Unequal
floor height
yes
yes
no
no *
yes
Same
floor height
yes
Unequal
floor height
yes
yes
no
Same
floor height
Unequal
floor height
yes
no
16
01750177940 C
Installation options
01750177940 C
17
Installation options
18
01750177940 C
Installation options
The specified measurements for the wall opening are the ergonomic
measurements, which are measured at the outside of the wall.
1 Outside wall
01750177940 C
19
Installation options
1 Outside wall
20
01750177940 C
Installation options
01750177940 C
21
Installation options
The specified measurements for the wall cutout (device version with
6cassette dispenser) are the ergonomic measurements which are
measured at the outside of the wall.
1 Outside wall
22
01750177940 C
Installation options
The specified measurements for the wall cutout (device version with
6cassette dispenser) are the ergonomic measurements which are
measured at the outside of the wall.
1 Outside wall
01750177940 C
23
Vents
Vents
The device features forced air ventilation on the right side of the top part and in
the door of the operating unit by means of built-in fans. Additionally, there are
vents on the left side piece. Make sure that the distance between the vents
and the wall is always at least 50 mm (1.97") (see also section "Space
required for operation and maintenance").
1 Vents
24
01750177940 C
If interior construction work has not yet been completed at the time of
installation, then it is absolutely necessary that the device be protected
from contamination caused by building dust. You may use the
protective plastic packing provided at the time of the delivery of the
system for this purpose.
01750177940 C
25
780 (30.71")
848 (33.39")
620 (24.41")
980 (38.58")
150 (5.91")
50
(1.97")
13.5
(0.53")
50
(1.97")
856 (33.7")
350
(13.78")
700 (27.56")
350
(13.78")
26
01750177940 C
780 (30.71")
848 (33.39")
620 (24.41")
980 (38.58")
130 (5.12")
410
(16.14")
50
(1.97")
13.5
(0.53")
50
(1.97")
856 (33.7")
350
(13.78")
01750177940 C
700 (27.56")
350
(13.78")
27
Installation option
Installation option
Installation options 4-cassette dispenser
The CINEO C2550 / ProCash 8050 (Gas) can be installed through the wall
with floors the same height on the inside and on the outside, with a higher floor
on the outside or with a higher floor on the inside.
Possible versions
The illustration below shows a higher floor level on the outside. The
descriptions also apply if the floor level is higher on the inside and if
the floor is on the same level on the inside and outside.
The three different versions:
I (height-adjustable installation rack)
II (222 mm (8.74") installation frame)
III (25 mm (0.98") installation frame)
are displayed in the following illustration.
28
01750177940 C
Installation option
x3
W**
5
6
x4
222
(8.74")
II:
25
(0.98")
870 (34.25")
935* (36.81"*)
648
(25.51")
25
(0.98")
I:
710
(27.95")
1890 (74.41")
615
(24.21")
X2
X5
X1
4
3
x5
III:
1
2
3
4
5
6
7
8
Device
Wall
Floor inside
Floor outside
Installation rack, top part
Installation rack, bottom part
222 mm (8.74") installation frame
25 mm (0.98") installation frame
9
X1
X2
X3
01750177940 C
29
Installation option
Version I:
Version II:
Version III:
30
01750177940 C
Installation option
The illustration below shows a higher floor level on the outside. The
descriptions also apply if the floor level is higher on the inside and if
the floor is on the same level on the inside and outside.
The two different versions:
I (82 mm (3.23") installation frame)
II (25 mm (0.98") installation frame)
are displayed on the right-hand side in the following illustration.
01750177940 C
31
82 (3.23")
Installation option
W**
2030 (79.92")
615
(24.21")
5
3
X2
25
(0.98")
X5
870 (34.25")
935* (36.81"*)
X1
788 (31.02")
710
(27.95")
I:
II:
6
7
4
3
1
2
3
4
5
Device
Wall
Floor inside
Floor outside
82 mm (3.23") installation frame
6
7
X1
X2
X5
32
01750177940 C
Version II:
Installation option
01750177940 C
33
Installation option
988* (38.9"*)
933 (36.73)
908 (35.75")
710
(27.95")
615
(24.21")
2150 (84.65")
W**
5
1 Device
2 Wall
3 Floor inside
4 Floor outside
5 25 mm (0.98") installation frame
34
01750177940 C
Load-carrying capacity
Make sure the floor space has the required load-carrying capacity. You will find
the corresponding device weight in the section "Installation specifications" in
the chapter "Appendix".
01750177940 C
35
The operator must provide a suitable base to protect it from removal by force.
We recommend reinforced concrete B25 (EN206 C20/25) or a higher-quality
concrete.
36
01750177940 C
01750177940 C
37
38
The installation frame must be secured using one threaded rod per
group of holes A to D. The installation frame is secured with a total of
four threaded rods.
01750177940 C
594 (23.39")
539 (21.22")
179
(7.05")
8
5
6
7
147 (5.79")
687 (27.05")
842 (33.15")
3
4
1
B
A
2
6
7
6
2
C
D
1
3
9
1 Attachment points
installation frame
2 Alternative attachment points
installation frame UL /
CEN L4 / CEN III / CEN IV
3 Safe attachment points
4 Attachment point
tear-off sensor
01750177940 C
7
6
5
39
634 (24.96")
559 (22.01")
199
(7.83")
8
5
6
7
147 (5.79")
687 (27.05")
842 (33.15")
3
4
1
B
A
2
6
7
6
2
C
D
1
3
9
1 Attachment points
installation frame
2 Alternative attachment points
installation frame
CEN III / CEN IV
3 Safe attachment points
4 Attachment point
Tear-off sensor
40
7
6
5
01750177940 C
569 (22.4")
533 (20.98")
483 (19.01")
25 (0.98")
130 (5.12")
429 (16.89")
347 (13.66")
247 (9.72")
8
6
7
391 (15.39")
712 (28.03")
451 (17.76")
737 (29.02")
817 (32.17")
7
6
7
6
25 (0.98")
5
9
62 (2.44")
202 (7.95")
5
6
7
8
9
01750177940 C
41
609 (23.98")
553 (21.77")
503 (19.80")
25 (0.98")
130 (5.12")
449 (17.68")
367 (14.45")
267 (10.51")
391 (15.39")
712 (28.03")
451 (17.76")
737 (29.02")
817 (32.17")
7
6
7
6
25 (0.98")
5
9
82 (3.23")
222 (8.74")
5
6
7
8
9
01750177940 C
If you want to set the CINEO C2550 / ProCash 8050 (Gas) on a base,
calculate the base height using the following formula (also see the illustration
in the section "Installation options 4-cassette dispenser" or "Installation options
5-cassette dispenser"):
Formula
X5base = X1wall 648 mm (25.51") 25 mm (0.98")
(installation frame)
X5base = X1wall 788 mm (31.02") 25 mm (0.98")
(installation frame)
X5
X1
648/788*
(25.51"/31.02"*)
Installation option
4cassette
dispenser:
5cassette
dispenser:
4
3
1 Device
2 Wall
3 Floor inside
4 Floor outside
X1 Height of wall opening (X1wall)
X5 Height of base (X5base)
01750177940 C
43
44
01750177940 C
The installation frame must be secured using one threaded rod (for
CEN L4 or CEN III) or two threaded rods (for CEN IV) per group of
holes A to D. The installation frame is secured with a total of four or
eight threaded rods.
594 (23.39")
539 (21.22")
179
(7.05")
5
6
842 (33.15")
687 (27.05")
147 (5.79")
3
A
1
2
4
7
6
7
2
C
1
3
6
5
9
1 Attachment points
installation frame
2 Additional attachment points
for CEN IV safe or alternative
attachment points for CEN L4 or
CEN III safe
3 Safe attachment points
4 Tear-off sensor attachment
points
01750177940 C
45
135 (5.31")
55 (2.17")
568 (22.36")
537 (21.14")
530 (20.87")
515 (20.28")
484 (19.06")
453 (17.83")
265 (10.43")
205
(8.07")
8
5
798 (31.42")
787 (30.98")
723 (28.46")
714 (28.11")
564 (22.2")
552 (21.73")
462 (18.19")
382 (15.04")
309 (12.17")
282 (11.1")
159 (6.26")
112 (4.41")
55 (2.17")
6
7
6
5
6
7
8
9
46
01750177940 C
01750177940 C
47
48
The installation frame must be secured using one threaded rod (for
UL / CEN L4 / CEN III safe) or two threaded rods (for CEN IV safe)
per group of holes A to D.
The installation frame is secured with a total of four or eight threaded
rods.
01750177940 C
594 (23.39")
539 (21.22")
179
(7.05")
8
5
6
842 (33.15")
687 (27.05")
147 (5.79")
1
2
4
7
6
7
1
3
6
5
9
1 Attachment points
installation frame
2 Additional attachment points for
CEN IV safe or alternative
attachment points for UL /
CEN L4 / CEN III safe
3 Safe attachment points
4 Tear-off sensor attachment
points
01750177940 C
49
634 (24.96")
559 (22.01")
199
(7.83")
8
5
6
842 (33.15")
687 (27.05")
147 (5.79")
1
2
4
7
6
7
1
3
6
5
9
1 Attachment points
installation frame
2 Additional attachment points for
CEN IV safe or alternative
attachment points for CEN III
safe
3 Safe attachment points
4 Tear-off sensor attachment
points
50
01750177940 C
159 (6.26")
112 (4.41")
55 (2.17")
798 (31.42")
787 (30.98")
723 (28.46")
714 (28.11")
564 (22.2")
552 (21.73")
462 (18.19")
382 (15.04")
309 (12.17")
282 (11.1")
5
6
7
6
5
6
7
8
9
01750177940 C
51
159 (6.26")
112 (4.41")
55 (2.17")
798 (31.42")
787 (30.98")
723 (28.46")
714 (28.11")
564 (22.2")
552 (21.73")
462 (18.19")
382 (15.04")
309 (12.17")
282 (11.1")
5
6
7
6
5
6
7
8
9
52
01750177940 C
01750177940 C
53
54
01750177940 C
The installation rack must be secured using one threaded rod for UL /
CEN L4 / CEN III safe) or two threaded rods (for CEN IV safe) per
group of holes A to D. The installation rack is secured with a total of
four or eight threaded rods.
566 (22.28")
7
814 (32.05")
1
6
1 Attachment points
installation rack
2 Additional attachment points
for CEN IV safe or alternative
attachment points for UL /
CEN L4 / CEN III safe
01750177940 C
4 Attachment point of
tear-off sensor
6 Area for cables
7 This side must always point to
the side with the safe door.
8 Customer panel side
55
7
594 (23.39")
539 (21.22")
147
(5.79")
179 (7.05")
5
3
687 (27.05")
842 (33.15")
4
3
8
3 Safe attachment points
4 Hole for tear-off sensor
5 Cable feed openings into
installation rack
56
01750177940 C
606 (23.89")
7
814 (32.05")
2
1
2
1
8
1 Attachment points
installation rack
2 Additional attachment points
for CEN IV safe or alternative
attachment points for CEN III
safe
01750177940 C
57
7
634 (24.96")
559 (22.01")
147
(5.79")
199 (7.84")
5
3
687 (27.05")
842 (33.15")
4
3
8
3 Safe attachment points
4 Hole for tear-off sensor
5 Cable feed openings into
installation rack
58
01750177940 C
659 (25.95")
539 (21.22")
293 (11.54")
528 (20.79")
453 (17.83")
448 (17.64")
433 (17.05")
413 (16.26")
113 (4.45")
7
15 (0.59")
50 (1.97")
113 (4.45")
173 (6.81")
50 (1.97")
8
6 Area for cables
7 This side must always point to the side with the safe door.
8 Customer panel side
01750177940 C
59
550 (21.65")
530 (20.87")
484 (19.06")
20 (0.79")
82 (3.23")
8
5 Cable feed openings into installation rack
7 This side must always point to the side with the safe door.
8 Customer panel side
60
01750177940 C
659 (25.95")
539 (21.22")
293 (11.54")
548 (21.58")
493 (19.41")
468 (18.43")
453 (17.84")
433 (17.05")
113 (4.45")
7
15 (0.59")
50 (1.97")
113 (4.45")
173 (6.81")
50 (1.97")
8
6 Area for cables
7 This side must always point to the side with the safe door.
8 Customer panel side
01750177940 C
61
570 (22.44")
550 (21.65")
504 (19.84")
20 (0.79")
82 (3.23")
8
5 Cable feed openings into installation rack
7 This side must always point to the side with the safe door.
8 Customer panel side
62
01750177940 C
from 130 mm
(5.12")
from 190 mm
(7.48")
from 320 mm
(12.6")
01750177940 C
Necessary height of
the installation rack
bottom part X4rack
93 mm
to
190 mm (7.48")
to
320 mm (12.6")
152 mm
to
270 mm
63
X3
X4
X2
X1
648
(25.51")
4
3
1
2
3
4
64
Device
Wall
Floor inside
Floor outside
X1
X2
X3
X4
01750177940 C
Tear-off sensor
Tear-off sensor
i
All safes and installation frames have holes for mounting a tear-off
sensor.
To ensure that the tear-off sensor can be mounted after the device has been
installed, a hole for the tear-off sensor has to be drilled at the time the
installation frame or the installation rack is mounted.
To be able to mount the tear-off sensor, the hole has to be cleaned with a
vacuum cleaner and a glass-bonding fixing (e.g. UPAT multicone, Fischer
resin cartridge R M) has to be inserted.
Thus the alarm technician will be able to mount the tear-off sensor in the safe
easily after the device is installed (see also illustration "Mounting structure" in
the corresponding sections of the chapter "Installation").
Ask your alarm technician about the size of the hole and the fixing. The
maximum diameter for the hole to take the fixing is:
22 mm (0.87") in UL / CEN safe
20 mm (0.79") in the 25 mm (0.98") installation frame
22 mm (0.87") in the 82 mm (3.23") installation frame and in the 222 mm
(8.74") installation frame
20 mm (0.79") in the installation rack
The mounting material (threaded rod, fixing, etc.) is to be provided by the
customer (alarm technician). The length of the threaded rod depends on the
installation frame or the installation rack you use (see chapter "Installation").
Drilling diagrams
The following illustrations indicate the drill holes that are used to secure the
CINEO C2550 / ProCash 8050 (Gas) to the installation frames or installation
racks (depending on the distance from the edge of the device (safe)).
01750177940 C
65
Drilling diagrams
The installation frame is 3 mm (0.12") smaller than the safe all around.
482 (18.98")
471.5 (18.56")
107 (4.21")
578 (22.76")
278 (10.94")
188 (7.4")
Drilling depths:
Holes for installation
frame:
Hole for tear-off
sensor:
66
01750177940 C
Drilling diagrams
502 (19.76")
492 (19.37")
127 (5.00")
668 (26.3")
578 (22.76")
278 (10.94")
188 (7.4")
150 (5.91")
Drilling depths:
Holes for installation
frame:
Hole for tear-off
sensor:
01750177940 C
67
Drilling diagrams
484 (19.06")
472 (18.58")
240
(9.45")
682 (26.85")
602 (23.70")
277 (10.91")
197 (7.76")
150 (5.91")
Drilling depths:
Holes for installation
frame:
Hole for tear-off
sensor:
68
01750177940 C
Drilling diagrams
The installation frame is 3 mm (0.12") smaller than the safe all around.
484 (19.06")
472 (18.58")
240
(9.45")
682 (26.85")
602 (23.70")
277 (10.91")
197 (7.76")
150 (5.91")
Drilling depths:
Holes for installation
frame:
Hole for tear-off
sensor:
01750177940 C
69
Drilling diagrams
504 (19.84")
492 (19.37")
260
(10.24")
682 (26.85")
602 (23.70")
277 (10.91")
197 (7.76")
150 (5.91")
Drilling depths:
Holes for installation
frame:
Hole for tear-off
sensor:
70
01750177940 C
Drilling diagrams
275 (10.83")
225 (8.86")
150 (5.91")
641 (25.24")
591 (23.27")
473 (18.62")
456 (17.95")
194 (7.65") 406 (15.98")
144 (5.67")
Drilling depths:
Holes for installation
frame:
Hole for tear-off
sensor:
01750177940 C
71
Drilling diagrams
214 (8.43")
164 (6.46")
493 (19.41")
476 (18.74")
426 (16.77")
641 (25.24")
591 (23.27")
275 (10.83")
225 (8.86")
150 (5.91")
Drilling depths:
Holes for installation
frame:
Hole for tear-off
sensor:
72
01750177940 C
Make sure that the cables provided on-site are long enough to be laid
through the installation frame into the safe.
Avoid excess lengths of cable by shortening them where necessary.
You must ensure that connecting cables do not impede or actually
damage any moving components.
01750177940 C
73
74
01750177940 C
2
3
4
L N PE
1 Fuse or automatic circuit-breaker
2 Connection for CINEO C2550 / ProCash 8050 (Gas) (incl. optional
heater)
3 Modem connection
4 Connection of miscellaneous equipment
01750177940 C
75
76
01750177940 C
01750177940 C
77
825 (32.48")
145 (5.71")
145 (5.71")
1645 (64.76")
1
607 (23.9")
670 (26.38")
72/43*
(2.83"/1.69"*)
848 (33.39")
1245 (49.02")
1 Shipping crate
* Standard lock: 43 mm (1.69")
Customer-specific lock: max. 72 mm (2.83")
78
01750177940 C
1615 (63.58")
965 (37.99")
145 (5.71")
1785 (70.28")
145 (5.71")
1
607 (23.9")
670 (26.38")
72/43*
(2.83"/1.69"*)
848 (33.39")
1245 (49.02")
1 Shipping crate
* Standard lock: 43 mm (1.69")
Customer-specific lock: max. 72 mm (2.83")
01750177940 C
79
1225 (48.23")
145 (5.71")
145 (5.71")
1905 (75")
1875 (73.82")
1
607 (23.9")
670 (26.38")
72/43*
(2.83"/1.69"*)
848 (33.39")
1245 (49.02")
1 Shipping crate
* Standard lock: 43 mm (1.69")
Customer-specific lock: max. 72 mm (2.83")
80
01750177940 C
670 (26.38")
520 (20.47")
1350 (53.15")
1617 (63.66")
01750177940 C
81
670 (26.38")
520 (20.47")
1900 (74.8")
690 (27.17")
1350 (53.15")
1617 (63.66")
82
01750177940 C
825 (32.48")
145 (5.71")
1645 (64.76")
145 (5.71")
1
607 (23.9")
670 (26.38")
72/43*
(2.83"/1.69"*)
848 (33.39")
1245 (49.02")
1 Shipping crate
* Standard lock: 43 mm (1.69")
Customer-specific lock: max. 72 mm (2.83")
01750177940 C
83
670 (26.38")
520 (20.47")
1350 (53.15")
1617 (63.66")
84
01750177940 C
670 (26.38")
520 (20.47")
1900 (74.8")
690 (27.17")
1350 (53.15")
1617 (63.66")
01750177940 C
85
86
01750177940 C
Installation
This chapter describes the individual steps to be taken to install the device.
From the time of installation to the time the device is put into service,
the climatic environmental conditions for storage must be met (see
chapter "Appendix").
Levels must not fall below or exceed these conditions because
irreparable damage may be caused to the device otherwise.
In the event of non-compliance, WINCOR NIXDORF
International GmbH shall not assume liability for any damage that is
caused to the device.
01750177940 C
87
Installation
88
To move the device push against the sides of the safe only as shown
in the illustration below.
01750177940 C
Installation
Disassembly
Proceed as follows to remove the shipping crate:
Remove the screws of the shipping
crate from underneath.
Carefully lift the device from the side
with the help of the lift truck.
Danger of tipping over: Do not
move the device in this state.
Remove the shipping crate from the
CINEO C2550 / ProCash 8050 (Gas)
(1).
01750177940 C
89
Mounting sets
Installation
Mounting sets
i
The mounting sets are supplied with the installation frame of the
CINEO C2550 / ProCash 8050 (Gas).
The mounting set for the tear-off sensor is not supplied with the
device.
Item
Mounting set for installation frame (supplied with
installation frame)
Caulking cartridge (two-component mortar)
A caulking gun is not included in the delivery
package.
Threaded rod M16 x 300
(DIN 976, property class 8.8)
Hexagon nut M16 (DIN 934-8)
Washer A 17 DIN 125-St
90
Quantity required
4
4
4
01750177940 C
Installation
Mounting sets
Item
Caulking cartridge
Quantity required
CEN L4 / CEN III CEN IV
*
1
2
4
4
8
8
* For a CEN IV safe two mounting sets are supplied with the 82 mm (3.23"),
222 mm (8.74") installation frame and the installation rack.
For mounting the 25 mm (0.98") installation frame, only one mounting set
is necessary.
01750177940 C
91
Mounting sets
Installation
Quantity required
4
4
Quantity required
4
4
92
Quantity required
4
4
01750177940 C
Installation
Same
floor height
Unequal
floor height
yes
yes
yes
no
no *
yes
Same
floor height
yes
Unequal
floor height
yes
yes
no
Same
floor height
yes
Unequal
floor height
no
01750177940 C
93
Installation
The installation frame for the CINEO C2550 / ProCash 8050 Gas is 40
mm (1.57") wider than the installation frame for the CINEO C2550 /
ProCash 8050.
Align the installation frame and mark the holes to be drilled for mounting
the installation frame (see illustration
below).
94
01750177940 C
Installation
The installation frame must be secured using one threaded rod per
group of holes A to D. The installation frame is secured with a total of
four threaded rods.
01750177940 C
95
Installation
First-time installation
5
3
1
2
7
2
9
11
12
13,5
(0.53")
10
12
W*
P*
590 (23.23")
283
(11.14")
303
(11.93")
1 Attachment points of
installation frame
2 Alternative attachment points of
installation frame for UL /
CEN L4 / CEN III / CEN IV
3 Safe attachment points
4 Tear-off sensor attachment points
5 Cable lead-ins in the installation
frame
311
(12.24")
331
(13.03")
6 Area for cables
7 Cable feed openings
underneath the installation frame
8 This side must always point to
the side with the safe door.
9 Customer panel side
10 Center of installation frame
11 Center of wall cutout
12 Wall
01750177940 C
Installation
5
6
3
1
2
C
9
11
12
2
1
6
5
13,5
(0.53")
10
12
W*
P*
550 (21.66")
311
283
(11.14") (12.24")
303
331
(11.93") (13.03")
1 Attachment points of
installation frame
2 Alternative attachment points of
installation frame for UL /
CEN L4 / CEN III / CEN IV
3 Safe attachment points
4 Tear-off sensor attachment points
5 Cable lead-ins in the installation
frame
01750177940 C
97
Installation
Drill the required four holes and the hole for the tear-off sensor, if
necessary (see following illustrations).
98
01750177940 C
Installation
25
(0.98")
UL
CEN
min. 40
(min. 1.57")
min. 125
(min. 4.92")
*
1
2
3
4
Safe
Mounting set for safe
Tear-off sensor
Installation frame
5
6
7
8
Screed
Concrete
Mounting set for installation frame
Top edge of finished floor
01750177940 C
99
Installation
25
(0.98")
UL
CEN
min. 40
(min. 1.57")
min. 125
(min. 4.92")
*
1
2
3
4
Safe
Mounting set for safe
Tear-off sensor
Installation frame
5 Concrete
6 Mounting set for installation frame
7 Top surface of base
100
01750177940 C
Installation
Remove filling piece 5b and possibly 5a from the cable lead-ins (see
positions 5a and 5b in the following illustration).
5a
Screw the installation frame to the base (for material see section "Mounting
sets").
If applicable, note the hardening times of the mounting material.
The threaded rods must not protrude beyond the installation frame.
If necessary, level the threaded rods.
01750177940 C
101
Installation
102
When lifting the CMD make sure that the connecting cables on the
rear side of the CMD controller are not damaged and that they are not
moved around!
01750177940 C
Installation
1
2
01750177940 C
103
Installation
When you're lowering it, make sure that the connecting cables on the
rear side of the CMD controller are not damaged and that they are not
moved around!
104
01750177940 C
Installation
General information
Close the device.
The locking axle and the track stops must remain in the safe for later
service operations.
01750177940 C
105
Installation
Align the installation frame and mark the holes to be drilled for mounting
the installation frame (see illustration
below).
106
01750177940 C
Installation
The installation frame must be fastened using one threaded rod (for
CEN L4 / CEN III) or two threaded rods (for CEN IV) per group of
holes A to D (see illustration below).
The installation frame is secured with a total of four or eight threaded
rods.
01750177940 C
107
Installation
First-time installation
5
3
A
1
B
7
6
3
11
9
6
5
13,5
(0.53")
10
12
P*
W*
12
590 (23.23")
311
283
(12.24")
(11.14")
1 Attachment points of
installation frame
2 Additional attachment points
for CEN IV safe or alternative
attachment points for CEN L4 /
3 CEN III safe
4 Safe attachment points
Tear-off sensor attachment points
5 Cable lead-ins in the installation
frame
108
01750177940 C
Installation
5
6
3
A
6
7
7
6
2
1
D
6
5
3
11
13,5
(0.53")
10
12
P*
12
W*
550 (21.66")
311
283
(12.24")
(11.14")
1 Attachment points of
installation frame
2 Additional attachment points
for CEN IV safe or alternative
attachment points for CEN L4 /
CEN III safe
3 Safe attachment points
4 Tear-off sensor attachment points
5 Cable lead-ins in the installation
frame
01750177940 C
109
Installation
Drill the required eight holes and the hole for the tear-off sensor, if
necessary (also see following illustrations).
110
01750177940 C
Installation
UL
CEN
Mounting structure
82
(3.23")
min. 40
(min. 1.57")
min. 125
(min. 4.92")
*
1
2
3
4
Safe
Mounting set for safe
Tear-off sensor
Installation frame
5
6
7
8
Screed
Concrete
Mounting set for installation frame
Top edge of finished floor
111
Installation
Remove filling piece 5b and possibly 5a from the cable lead-ins (see
positions 5a and 5b in the following illustration).
5a
Screw the installation frame to the base (for material see section "Mounting
sets").
If applicable, note the hardening times of the mounting material.
112
The threaded rods must not protrude beyond the installation frame.
If necessary, level the threaded rods.
01750177940 C
Installation
When lifting the CMD make sure that the connecting cables on the
rear side of the CMD controller are not damaged and that they are not
moved around!
01750177940 C
113
Installation
114
01750177940 C
Installation
When you're lowering it, make sure that the connecting cables on the
rear side of the CMD controller are not damaged and that they are not
moved around!
01750177940 C
115
Installation
General information
Close the device.
The locking axle and the track stops must remain in the safe for later
service operations.
116
01750177940 C
Installation
The installation frame for the CINEO C2550 / ProCash 8050 Gas is 40
mm (1.57") wider than the installation frame for the CINEO C2550 /
ProCash 8050.
117
Installation
Align the installation frame and mark the holes to be drilled for mounting
the installation frame (see illustration below).
118
01750177940 C
Installation
First-time installation
5
6
3
A
6
7
7
6
2
1
3
11
9
13,5
(0.53")
10
6
5
12
W*
P*
12
590 (23.23")
311
283
(12.24")
(11.14")
331
303
(11.93")
(13.03")
1 Attachment points of
installation frame
2 Additional attachment points
for CEN IV safe or alternative
attachment points for UL /
CEN L4 / CEN III safe
3 Safe attachment points
4 Tear-off sensor attachment points
5 Cable lead-ins in the installation
frame
01750177940 C
119
Installation
5
6
3
A
1
2
6
7
7
6
2
1
D
6
5
3
11
13,5
(0.53")
10
12
P*
12
W*
550 (21.66")
283
311
(11.14")
(12.24")
331
303
(13.03")
(11.93")
1 Attachment points of
installation frame
2 Additional attachment points
for CEN IV safe or alternative
attachment points for UL /
CEN L4 / CEN III safe
3 Safe attachment points
4 Tear-off sensor attachment points
5 Cable lead-ins in the installation
frame
120
01750177940 C
Installation
Drill the required four or eight holes and the hole for the tear-off sensor, if
necessary (see illustration below).
01750177940 C
121
Installation
Mounting structure
UL
CEN
222 (8.74")
min. 40
(min. 1.57")
min. 125
(min. 4.92")
*
1
2
3
4
Safe
Tear-off sensor
Screed
Concrete
5
6
7
8
122
01750177940 C
Installation
5a
Screw the installation frame to the floor (for material see section "Mounting
sets"). If applicable, note the hardening times of the mounting material.
01750177940 C
123
Installation
124
When lifting the CMD make sure that the connecting cables on the
rear side of the CMD controller are not damaged and that they are not
moved around!
01750177940 C
Installation
01750177940 C
125
Installation
When you're lowering it, make sure that the connecting cables on the
rear side of the CMD controller are not damaged and that they are not
moved around!
126
01750177940 C
Installation
General information
Close the device.
The locking axle and the track stops must remain in the safe for later
service operations.
01750177940 C
127
Installation
X3
X4
X2
X1
648
(25.51")
Overview
4
3
1
2
3
4
128
Device
Wall
Floor inside
Floor outside
X1
X2
X3
X4
01750177940 C
Installation
from 130 mm
(5.12")
from 190 mm
(7.48")
from 320 mm
(12.6")
01750177940 C
Necessary height of
the installation rack
bottom part X4rack
93 mm
to
190 mm (7.48")
to
320 mm (12.6")
152 mm
to
270 mm
129
Installation
The installation rack for the CINEO C2550 / ProCash 8050 Gas is 40
mm (1.57") wider than the installation rack for the CINEO C2550 /
ProCash 8050.
130
01750177940 C
Installation
First-time installation
6
4
2
1
B
6
2
1
11
13,5
(0.53")
9
11
P*
10
W*
590 (23.23")
269
(10.59")
289
(11.35")
1 Attachment points
installation rack
2 Additional attachment points
of CEN IV safe or alternative
attachment points of UL /
CEN L4 / CEN III safe
4 Attachment point of tear-off
sensor
297
(11.69")
317
(12.48")
01750177940 C
131
Installation
6
4
2
1
B
6
2
1
13,5
(0.53")
9
11
P*
10
11
W*
550 (21.66")
269
(10.59")
289
(11.35")
1 Attachment points
installation rack
2 Additional attachment points
of CEN IV safe or alternative
attachment points of UL /
CEN L4 / CEN III safe
4 Attachment point of tear-off
sensor
297
(11.69")
317
(12.48")
132
01750177940 C
Installation
If a tear-off sensor is to be
installed as agreed with the
financial institution or the alarm
technician, also mark the holes
for the tear-off sensor (2).
01750177940 C
133
Installation
134
01750177940 C
Installation
Mounting structure
UL
CEN
min. 40
(min. 1.57")
min. 125
(min. 4.92")
*
1
2
3
4
Safe
Tear-off sensor
Screed
Concrete
5
6
7
8
01750177940 C
135
Installation
136
01750177940 C
Installation
4x CEN III
8x CEN IV
Insert the sealing plugs in the screwon points with a few hammer strokes (1),
where the threaded rods were fastened
before with nuts and washers.
01750177940 C
137
Installation
Turn the top part of the installation rack around and place it on the bottom
part.
Turn the nuts on the four threaded rods of the top part to adjust the height
of the installation rack. The distance from top edge of the top part to the
lower edge of the hole in the wall has to be 648 mm (25.51").
Make sure that the top part of the installation rack is horizontal.
138
01750177940 C
Installation
Use spacers and nuts to retain the height that you have set.
To do this, place the spacers and nuts on the threaded rods in the bottom
part of the installation rack. Tighten the four nuts (see illustration below).
4x
01750177940 C
139
Installation
CEN only:
4x
Remove the relevant filling piece from the cable lead-in in the top part of
the installation rack (see position 1 in the next illustration).
140
01750177940 C
Installation
When lifting the CMD make sure that the connecting cables on the
rear side of the CMD controller are not damaged and that they are not
moved around!
01750177940 C
141
Installation
142
01750177940 C
Installation
When you're lowering it, make sure that the connecting cables on the
rear side of the CMD controller are not damaged and that they are not
moved around!
01750177940 C
143
Installation
General information
Close the device.
The locking axle and the track stops must remain in the safe for later
service operations.
144
01750177940 C
Installation
Installation is to the greatest extent the same for a tunnel frame with
and without illumination. Any differences that exist are described here
explicitly. The illustrations show the device with illumination.
01750177940 C
145
Installation
Push the two release levers of the customer panel down (1). Pull the
customer panel as far as possible out of the device (2).
146
01750177940 C
Installation
01750177940 C
147
Installation
5x
Push the sealing frame over the customer panel (1) into the wall opening
until it touches the outer wall all around.
Attach the sealing frame to the device at the five attachment points (2)
(right, left and bottom one screw each, top two screws).
148
01750177940 C
Installation
01750177940 C
149
Installation
2x
Put the two adjusting plates in place on the right and left side of the
customer panel (1). Attach each adjusting plate with a screw (2).
Insert the four bolts from below (1).
Attach them with one circlip each (2).
4x
4x
150
01750177940 C
Installation
Loosen the securing screw of the customer panel. Rotate the securing
screw back until it no longer sits in the lower groove of the track (see
section "Pulling out/pushing in the customer panel").
Push the customer panel into the device until the locking/release levers
click into place.
Installation in a masonry facade:
Tighten the two adjusting bolts which
you will find on each adjusting plate
until they touch the sealing frame (see
arrow 1).
Installation in a glass facade:
Turn the two adjusting bolts on each
adjusting plate (see arrow 1) until they
are about 2 to 3 mm (0.08" to 0.11")
away from the sealing frame.
Unlock the operating unit, pull it out as far as possible and secure the
customer panel with a screw so that it cannot accidentally close/bang shut
(see section "Pulling out/pushing in the customer panel").
Secure each adjusting bolt with a corresponding nut.
01750177940 C
151
Installation
152
01750177940 C
Installation
3
2
1
Lay the cable leaving the customer panel electronics (1) underneath the
EMC seal (2) and the plate of the tunnel frame (3). Raise the EMC seal (2)
slightly here (see arrow).
Lay the cable in such a way that it will not be damaged when the
customer panel is pulled out or pushed in.
Insert the connector of the cable into
the mount (see arrow 1).
01750177940 C
153
Installation
Now connect the cable of the logo light to the connector (see arrow 1).
154
01750177940 C
Installation
Tighten the four nuts at the top of the tunnel frame (1).
Attach the tunnel frame to the adjusting plates on the left (2) and on the
right (3) using two nuts on each side.
Loosen the securing screw. Rotate the securing screw back until it no
longer sits in the lower groove of the track (see section "Pulling out /
pushing in the customer panel").
Then push the customer panel into the device until the locking/release
levers click into place.
Close the device.
01750177940 C
155
Start-up
Installation
Start-up
The service technician will connect the power and data cables.
156
You have to check that the power plugs are fitted correctly before
using the power switch on the power distributor.
01750177940 C
Installation
Start-up
Plug all power plugs (1) in the power
distributor.
Before the start-up of the CINEO C2550 / ProCash 8050 there has to
be a plug connection inside the UPS.
Open the CINEO C2550 / ProCash 8050 and gain access to the UPS (for
its position in the CINEO C2550 / ProCash 8050 please refer to the chapter
"Device Overview"; for its accessibility refer to the chapter "Basic
Operation" in the operating manual).
01750177940 C
157
Start-up
Installation
Pull the upper left-hand side of the
housing cover forwards and remove
the cover.
158
01750177940 C
Installation
Start-up
01750177940 C
159
Start-up
160
Installation
01750177940 C
1
2
3
Pos. Item
Quantity required
1
1 Remote Status Indicator - Standard (01750047663)
with 50 m (164.1 ft) connecting cable
(dimensions: 101.2 x 45.7 x 27 mm
(3.98" x 1.8" x 1.06") (W x H x D))
2 Phillips screws SPAX 2.5 x 20 mm (0.098" x 0.787" )
2
(countersunk head)
3 Fixings 4 mm (0.16")
2
01750177940 C
161
Installation
Remove the standard remote status indicator from the packaging.
Use a screwdriver to press carefully
through openings (1) and (2) until the
tabs behind them disengage.
1
3
In masonry only:
Drill the necessary bores: drill depth: 20 mm (0.79"), drill diameter:
4 mm (0.16"), and insert the enclosed fixings in the holes.
Secure the lower section to the wall
with the enclosed screws and press
the front cover onto the lower section.
162
01750177940 C
Lay the connecting cable of the standard remote status indicator to the
appropriate device.
The wires are marked with an adhesive label at the end as follows:
RED
WHITE
GREEN
BLACK
- 11 RED LIGHT
- 12 YELLOW LIGHT
- 13 GREEN LIGHT
- 14 GND
01750177940 C
163
Connect the individual wires to the relay panel for external features as
follows:
11 121314
Pin
11
12
13
14
Name
Wire 'RED - 11 RED LIGHT'
Wire 'WHITE - 12 YELLOW LIGHT'
Wire 'GREEN - 13 GREEN LIGHT'
Wire 'BLACK - 14 GND'
164
01750177940 C
2
3
Pos. Item
1 Remote Status Indicator - Audio (01750069332)
with 50 m (164.1 ft) connecting cable
(dimensions: 118 x 96.5 x 40.5 mm
(4.65" x 3.8" x 1.59") (W x H x D))
2 Phillips screws SPAX 4 x 40 mm (0.157" x 1.575" )
(half-round screws)
3 Fixings 6 mm (0.24")
Quantity required
1
2
2
01750177940 C
165
Installation
Remove the audio remote status indicator from the packaging.
Loosen screw (1). Move the back
panel (2) to one side at the bottom and
pull the panel downwards out of the
front cover.
In masonry only:
Drill the necessary bores: drill depth: 40 mm (1.57"), drill diameter:
6 mm (0.24"), and insert the enclosed fixings in the holes.
166
01750177940 C
Lay the connecting cable of the audio Remote Status Indicator to the
appropriate device.
01750177940 C
167
The wires are marked with an adhesive label at the end as follows:
RED
WHITE
GREEN
BLACK
168
- 11 RED LIGHT
- 12 YELLOW LIGHT
- 13 GREEN LIGHT
- 14 GND
01750177940 C
Connect the individual wires to the relay panel for external features as
follows:
11 121314
Pin
11
12
13
14
Name
Wire 'RED - 11 RED LIGHT'
Wire 'WHITE - 12 YELLOW LIGHT'
Wire 'GREEN - 13 GREEN LIGHT'
Wire 'BLACK - 14 GND'
01750177940 C
169
7
(0.28")
170
01750177940 C
2
3
4.5
(0.18")
Lead the connecting cable through the opening in the lower section and
secure it with the strain relief.
Marking on wires
The wires are marked with an adhesive label at the end as follows:
RED
WHITE
GREEN
BLACK
- RED LIGHT
- YELLOW LIGHT
- GREEN LIGHT
- GND
01750177940 C
171
Pin
1
2
3
4
Name
Wire 'RED - RED LIGHT'
Wire 'WHITE - YELLOW LIGHT'
Wire 'GREEN - GREEN LIGHT'
Wire 'BLACK - GND'
Press the front cover onto the lower section. Ensure that no wires are
damaged in the process.
172
01750177940 C
01750177940 C
173
25
(0.98")
4.5
(0.18")
174
01750177940 C
Marking on wires
The wires are marked with an adhesive label at the end as follows:
RED
WHITE
GREEN
BLACK
- RED LIGHT
- YELLOW LIGHT
- GREEN LIGHT
- GND
Pin
1
2
3
4
Name
Wire 'RED - RED LIGHT'
Wire 'WHITE - YELLOW LIGHT'
Wire 'GREEN - GREEN LIGHT'
Wire 'BLACK - GND'
Press the connecting cable with the spacer into the cable guide (2).
Mount the board and the back panel as described above under removal.
01750177940 C
175
176
01750177940 C
Appendix
Check list for installation preparations for
self-service systems
KS number *
Device type
Customer address
Name
Street
Town
Telephone
Contact
*
Order number
Delivery address/location
This check list has been created for all self-service systems. Most questions
can be answered yes or no. Some empty space is provided in the section
"Notes concerning installation preparation" for your convenience if you want to
note any questions or drafts.
After checking off all items, copy this list, send it to your head of
operations and make arrangements for an installation date.
Name:
Telephone number:
Fax number:
01750177940 C
177
General information
Installation
in front of a wall
through a wall
freestanding
encased
yes
no
OK
yes
no
OK
Preparations
Construction work
Is the securing of cash-dispensers in the raw
concrete ensured (CEN standard)?
Is the frame aligned and fastened in accordance
with the installation instructions?
Has a wall cutout that may be required been
completed?
Are the ambient conditions met?
178
01750177940 C
no
OK
yes
no
OK
Organizational preparations
Is the generation prepared on the host?
Has the MM module or CIM06 been ordered and
is it available?
Have the encryption/decryption or EPP keys been
prepared?
Is the paper and money ready for start-up?
Have you discussed the diameter of the hole that
is to be drilled and the fixing to be used for the
tear-off sensor with the local alarm provider?
Diameter?
Fixing to be used?
01750177940 C
179
no
OK
Carpet
Raised floor
Marble floor
Tiles
Others
Checked by customer:
180
01750177940 C
01750177940 C
181
182
01750177940 C
Appendix
Technical Data
Technical Data
General Installation Conditions
Electrical characteristics of the supply network
Supply voltage range:
Rated frequency
Network type
Permissible tolerance
for rated voltage
Permissible tolerance
for rated frequency
01750177940 C
110-120 V
50/60 Hz
TN
Network with PE
conductor
- 10% / + 6%
220 - 240 V
50/60 Hz
TN
Network with PE
conductor
- 10% / + 6%
1 %
1 %
183
Technical Data
Appendix
Device Conditions
110 - 120 V
220 - 240 V
Idle mode Operation Idle mode Operation
(maximum)
(maximum)
without UPS
Rated current
consumption
Apparent power
consumption
Active power
Power factor
with UPS
Rated current
consumption
Apparent power
consumption
Active power
Power factor
Heating 1 (without
device)
Rated current
consumption
Active power
184
1.5 A
2.6 A
0.8 A
1.3 A
155 VA
250 VA
175 VA
310 VA
135 W
0.94
225 W
0.97
135 W
0.77
220 W
0.77
2.3 A
3.4 A
1.2 A
1.8 A
240 VA
350 VA
230 VA
355 VA
210 W
0.83
325 W
0.83
190 W
0.76
300 W
0.76
3.5 A
1.8 A
410 W
410 W
01750177940 C
Appendix
Technical Data
110 - 120 V
Idle
Operation
mode
(maximum)
<3.5 mA
<3.5 mA
Leakage current
Protection class
Country-specific
safety plug
Country-specific
safety plug
Degree of protection in
acc. with EN 60529:
Outdoors:
IP 54
Indoors:
IP 20
01750177940 C
220 - 240 V
Idle
Operation
mode
(maximum)
<3.5 mA
<3.5 mA
IP 54
IP 20
185
Technical Data
Appendix
Installation specifications
CINEO C2550 / ProCash 8050
Dimensions:
Height:
Width:
Depth:
Depth with 41 mm
(1.61") tunnel:
Operation and maintenance
space:
Device weight:
UL Safe:
CEN L safe:
CEN III safe:
CEN IV safe:
CEN L4 safe
Surface load:
UL Safe:
CEN L safe:
CEN III safe:
CEN IV safe:
CEN L4 safe
186
4-cassette
dispenser
1500 mm
600 mm
848 mm
1214 mm
2.10 m2
740
590
890
910
780
15.81
12.61
19.02
19.45
15.33
kg
kg
kg
kg
kg
kN/m2
kN/m2
kN/m2
kN/m2
kN/m2
5-cassette
dispenser
1640 mm
600 mm
848 mm
1214 mm
6-cassette
dispenser
1760 mm
600 mm
848 mm
1214 mm
2.10 m2
2.10 m2
985 kg
985 kg
820 kg
19.37 kN/m2
19.37 kN/m2
16.12 kN/m2
790 kg
15.53 kN/m2
-
01750177940 C
Appendix
Technical Data
4-cassette
dispenser
1500 mm
675 mm
848 mm
1256 mm
2.12 m2
1040 kg
1060 kg
20.72 kN/m2
21.12 kN/m2
01750177940 C
187
Technical Data
Appendix
Environmental Conditions
Fan capacity:
Heat dissipation:
210 W
Air temperature C
+5 to +35
-40 to +50
+5 to +40
-25 to +60
+5 to +40
** In the limit range the device may only be operated for a short period of
time.
Operation
Transport (in
original packing)
Storage (in original
packaging)
188
2M2
1M3
Remarks
Building without significant vibrations caused
by other objects
All types of trucks and trailers, as well as rail
and air transport
Noticeable vibration and bumps caused for
example by machines or passing vehicles
01750177940 C
Appendix
Technical Data
Idle mode
Operation *
5.5 B
6.5 B
41 dB
51 dB
01750177940 C
189
Appendix
IEC 60950,
EN 60950,
CSA C22.2-60950,
UL 60950,
BSMI Standard CNS 14336
EMC standards:
EN 55022 / B,
EN 55024,
FCC CFR 47, part 15, subpart B, class A,
ICES-003 (CSA 108.8),
BSMI-Standard CNS 13438 class B
Conformity
The CE mark of conformity attached to the product or its package indicates
that the product complies with the requirements of the following EC directives:
EMC Directive 2004/108/EC
Low Voltage Directive 2006/95/EC
The corresponding statement of compliance has been issued by:
WINCOR NIXDORF International GmbH
Heinz-Nixdorf-Ring 1
33106 Paderborn
Germany
190
01750177940 C
Appendix
01750177940 C
191
Environmental protection
Appendix
Environmental protection
Environmentally and recycling-friendly product
development
This product has been designed according to our corporate guideline
'Environmentally and recycling-friendly product development'.
This means that crucial criteria such as long life, choice of material and its
labeling, emissions, packaging, ease of disassembly and recyclability have
been taken into account. This saves resources and relieves the strain on the
environment.
Saving energy
Please switch on devices that need not be constantly running only when they
are actually needed. They should also be turned off when they are not needed
for longer periods of time.
192
01750177940 C
Appendix
Environmental protection
01750177940 C
193
Environmental protection
194
Appendix
01750177940 C
Notes
01750177940 C
Published by
WINCOR NIXDORF International GmbH
D-33094 Paderborn
Order No.:
01750177940 C
GB