Vous êtes sur la page 1sur 6

MUNICIPALITY OF PIO V.

CORPUS

TABLE OF CONTENTS
A 3
1 6

LAND USE AND ZONING


FLOOR PLAN
FRONT ELEVATION
LEFT / RIGHT ELEVATION
REAR ELEVATION

A 3
3 6

COLUMN FOOTING DETAIL


WALL FOOTING DETAIL
BEAM SCHEDULE
BEAM DETAIL

1
6

D 1
1 6

PERSPECTIVE

PERSPECTIVE
SITE DEVELOPMENT PLAN

A 3
2 6

D 1
1 6

OFFICE OF THE BUILDING


OFFICIALS

LINE AND GRADE

GENERAL NOTES AND SPECIFICATION


SCHEDULE OF LOADS
LEGENDS
RISER DIAGRAM
LIGHTING AND POWER LAYOUT

ARCHITECTURAL

WASTE WATER LAYOUT


CLEAN WATER LAYOUT
SEPTIC TANK DETAIL
CATCH BASIN DETAIL
LEGEND

CIVIL / STRUCTURAL

SECTION
SCHEDULE OF WINDOW
SCHEDULE OF DOORS & VENTS
STAIR DETAIL

ELECTRICAL

MECHANICAL

SANITARY

PLUMBING

GEODETIC

ELECTRONICS

VICINITY MAP
PREPARED BY :

REPUBLIC OF THE PHILIPPINES


PROVINCE OF MASBATE
MUNICIPALITY OF PIO V. CORPUS
DEPARTMENT OF INTERIOR AND LOCAL
GOVERNMENT

KERWIN JAY C. CONDOR


Municipality of Pio V. Corpus

LOCATION PLAN
PROJECT TITLE / LOCATION :

REVIEWED / CHECKED BY :

RECOMMENDING APPROVAL :

APPROVED BY :

PROPOSED :

EVACUATION FACILITY - 1 UNIT STANDARD


EVACUATION CENTER
TANQUE, PIO V. CORPUS, MASBATE

JUVY S. CHING
MUNICIPAL ENGINEER

HERMINA BACALSO
MPDO / LPRAP

HON. ALLAN T. LEPASANA


MUNICIPAL MAYOR

SHEET CONTENT:
PERSPECTIVE
LOCATION MAP
VICINITY MAP

SHEET NO :

A 3
1 6

4
2
3

SPECIFICATIONS

PLAN

Z
M

SECTION

CATCH BASIN DETAIL

2
3

CLEAN WATER LAYOUT

PLAN

AIR SPACE
SCUM LEVEL

DIGESTION CHAMBER

LEACHING WELL

WASTE WATER LAYOUT

SECTION

SEPTIC TANK DETAIL


PREPARED BY :

REPUBLIC OF THE PHILIPPINES


PROVINCE OF MASBATE
MUNICIPALITY OF PIO V. CORPUS
DEPARTMENT OF INTERIOR AND LOCAL
GOVERNMENT

PROJECT TITLE / LOCATION :

KERWIN JAY C. CONDOR


Municipality of Castilla

REVIEWED / CHECKED BY :

RECOMMENDING APPROVAL :

APPROVED BY :

PROPOSED :

EVACUATION FACILITY - 1 UNIT STANDARD


EVACUATION CENTER
TANQUE, PIO V. CORPUS, MASBATE

JUVY S. CHING
MUNICIPAL ENGINEER

HERMINA BACALSO
MPDO

HON. ALLAN T. LEPASANA


MUNICIPAL MAYOR

SHEET CONTENT:
CLEAN WATER LAY-OUT
WASTE WATER LAY - OUT
CATCH BASIN DETAIL
SEPTIC TANK DETAIL

SHEET NO :

D 2
1 6

TOP OF ROOF DECK

FINISH FLOOR LINE

KITCHEN AND SINK

RETRACTABLE / SLIDING PARTITION

CLINIC BEDROOM

RETRACTABLE / SLIDING PARTITION

2
3

MALE T & B

FEMALE T & B

FINISH GRADE LINE

NURSE STATION

FRONT ELEVATION

TOP OF ROOF DECK

FLOOR PLAN

FINISH FLOOR LINE


FINISH GRADE LINE

REAR ELEVATION
1

2
4

LEFT SIDE ELEVATION


PREPARED BY :

REPUBLIC OF THE PHILIPPINES


PROVINCE OF MASBATE
MUNICIPALITY OF PIO V. CORPUS
DEPARTMENT OF INTERIOR AND LOCAL
GOVERNMENT

KERWIN JAY C. CONDOR


Municipality of Pio V. Corpus

RIGHT SIDE ELEVATION


PROJECT TITLE / LOCATION :

REVIEWED / CHECKED BY :

RECOMMENDING APPROVAL :

APPROVED BY :

PROPOSED :

EVACUATION FACILITY - 1 UNIT STANDARD


EVACUATION CENTER
TANQUE, PIO V. CORPUS, MASBATE

JUVY S. CHING

HERMINA BACALSO

HON. ALLAN T. LEPASANA


MUNICIPAL MAYOR

SHEET CONTENT:
FLOOR PLAN
FRONT ELEVATION
REAR ELEVATION
RIGHT SIDE ELEVATION
LEFT SIDE ELEVATION

SHEET NO :

A 3
2 6

SYMBOLS & LEGENDS

SCHEDULE OF LOADS :

ELECTRICAL NOTES

DESCRIPTION

1.0

GENERAL ELECTRICAL SYMBOLS

NO.

VOLTS

WATTS

CURRENT
RATING

WIRE SIZE

L. O.

11

230

600

2.61

2-2.0mm THHN in 19mm PVC

L. O.

11

230

600

2.61

2-2.0mm THHN in 19mm PVC

C. O.

230

1080

4.70

2-3.5mm THHN in 19mm PVC

C. O.

230

1080

4.70

2-3.5mm THHN in 19mm PVC

SPARE

230

1080

SPARE

230

1080
SERVICE ENTRANCE FROM
SORECO II 240V

M
CIRCUIT BREAKER

RISER DIAGRAM

2.0

LIGHTING OUTLET

LIGHTING OUTLET

POWER OUTLET

POWER OUTLET

SPARE

SPARE

LIGHTING FIXTURES

OUTLETS & BOXES

4.0

SWITCHES SYMBOLS

1
2

3.0

2
3

2
3

EARTH GROUND

PREPARED BY :

KERWIN JAY C. CONDOR


Municipality of Pio V. Corpus

PROJECT TITLE / LOCATION :

REVIEWED / CHECKED BY :

RECOMMENDING APPROVAL :

APPROVED BY :

PROPOSED :

EVACUATION FACILITY - 1 UNIT STANDARD


EVACUATION CENTER
TANQUE, PIO V. CORPUS, MASBATE

POWER LAYOUT

LIGHTING LAYOUT
REPUBLIC OF THE PHILIPPINES
PROVINCE OF MASBATE
MUNICIPALITY OF PIO V. CORPUS
DEPARTMENT OF INTERIOR AND LOCAL
GOVERNMENT

JUVY S. CHING
MUNICIPAL ENGINEER

HERMINA BACALSO
MPDO

HON. ALLAN T. LEPASANA


MUNICIPAL MAYOR

SHEET CONTENT:
LIGHTNING LAY-OUT
POWER LAY-OUT
RISER DIAGRAM

SHEET NO :

1
6

CF1
L/4

L/4

L/4

L/4

L/4

L/4

2
3

SECTION

SLAB DETAIL
SCALE :

FOOTING DETAIL

1 : 100 m

PLAN

CF2

ROOF SLAB BEAM FRAMING


RB1

RB2

WF1
SECTION

2
3

CF2

CF1

CF1

CF1

CF1

CF2

CF2

CF2

CF1

CF1

CF1

CF1

CF1

PLAN
WF2

TYPICAL BEAM DETAIL


WALL FOOTING & TIE BEAM SCHEDULE
L
CF1 1.2
CF2 1.0

1.2

1.5

0.3

1.0

1.2

0.3

FOOTING SCHEDULES

TB

0.3

0.3

1.0

WF

0.4

0.20 0.8

KERWIN JAY C. CONDOR


Municipality of Pio V. Corpus

PROJECT TITLE / LOCATION :

FOUNDATION PLAN

TIE BEAM SCHEDULES

PREPARED BY :

REPUBLIC OF THE PHILIPPINES


PROVINCE OF MASBATE
MUNICIPALITY OF PIO V. CORPUS
DEPARTMENT OF INTERIOR AND LOCAL
GOVERNMENT

CF1

REVIEWED / CHECKED BY :

RECOMMENDING APPROVAL :

APPROVED BY :

PROPOSED :

EVACUATION FACILITY - 1 UNIT STANDARD


EVACUATION CENTER
TANQUE, PIO V. CORPUS, MASBATE

JUVY S. CHING
MUNICIPAL ENGINEER

HERMINA BACALSO
MPDO / LPRAP

HON. ALLAN T. LEPASANA


MUNICIPAL MAYOR

SHEET CONTENT:
SLAB DETAIL
TYPICAL BEAM DETAIL
FOOTING SCHEDULES
TIE BEAM SCHEDULES
FOOTING DETAIL
ROOF SLAB & FOUNDATION PLAN

SHEET NO :

A 3
3 6

STEEL CASEMENT WINDOW


w/ TRANSOM 6" CLEAR THK GLASS
2 SETS

STEEL CASEMENT WINDOW


w/ TRANSOM 6" CLEAR THK GLASS
6 SETS

FINISH FLOOR LINE

FINISH FLOOR LINE

STEEL CASEMENT WINDOW


w/ TRANSOM 6" CLEAR THK GLASS
1 SET

FINISH FLOOR LINE

STEEL CASEMENT WINDOW


w/ TRANSOM 6" CLEAR THK GLASS
1 SET
STEEL CASEMENT WINDOW
6" CLEAR THK GLASS
1 SET

FINISH FLOOR LINE

FINISH FLOOR LINE

STEEL CASEMENT WINDOW


6" CLEAR THK GLASS
2 SETS

SECTION THRU "A"

FINISH FLOOR LINE

FINISH FLOOR LINE

FINISH FLOOR LINE

FINISH FLOOR LINE

FLUSH DOOR
4 SETS

WOOD PANEL DOOR


w/ GOOD LUMBER WOOD
JAMB and TRANSOM
2 SETS

DOOR AND WINDOW SCHEDULE

PREPARED BY :

REPUBLIC OF THE PHILIPPINES


PROVINCE OF MASBATE
MUNICIPALITY OF PIO V. CORPUS
DEPARTMENT OF INTERIOR AND LOCAL
GOVERNMENT

KERWIN JAY C. CONDOR


Municipality of Pio V. Corpus

STAIR DETAIL

PROJECT TITLE / LOCATION :

REVIEWED / CHECKED BY :

RECOMMENDING APPROVAL :

APPROVED BY :

PROPOSED :

EVACUATION FACILITY - 1 UNIT STANDARD


EVACUATION CENTER
TANQUE, PIO V. CORPUS, MASBATE

JUVY S. CHING
MUNICIPAL ENGINEER

HERMINA BACALSO
MPDO / LPRAP

HON. ALLAN T. LEPASANA


MUNICIPAL MAYOR

SHEET CONTENT:
DOORS
WINDOW
SECTION THRU
STAIR DETAIL

SHEET NO :

D 2
2 6

Vous aimerez peut-être aussi