Ifinthecasewhereanextracentrifugalpumpisboughtbutitisdecidedlaternottobeused,whatarethecriteriato
determinewhetheritissuitabletobeusedforothersimilartypeofsysteminthefuture(foregwaterinjectionsystem).I
knowpumpcapacityisimportant,buthowaboutdestinationpressureortotalheadavailable?

Posted03March201409:58AM

markymaark

Checktheliteraturethatcamewiththepump,i.ethepumpcurve.Ifyoursystemcurveofthenewsystemmesheswiththe
pumpcurvethenyouareOK.

Ifnot,youcanalsolookintotrimmingtheimpellerblades,orbuyingawholenewimpelleritselftobetterfityournewsystem.

AndifthepumphasaVFDthenyouhaveplentymoreflexibility.

http://www.cheresources.com/invision/topic/20207criteriatodetermineadequacyofexistingpump/

1/3

12/23/2015

CriteriaToDetermineAdequacyOfExistingPumpIndustrialProfessionalsCheresources.comCommunity

Posted03March201412:26PM

ArtMontemayor

Itisalwaysregardedassmartengineeringtoalwaysprepareasystemcurveforacentrifugal
pump.Thissystemcurveshouldbedevelopedanddrawnontopofthepump'sperformance
curve.

Whenyoudothistoanycentrifugalpump'sperformancecurve,youimmediatelyknowjusthow
practicalandapplicabletheproposedpumpisforthegivensystem.

Posted03March201408:26PM

AlertO
hijanson
ifyourfluidserviceisthesame,itisquitestraightforwardmethod.
1.thenewrequiredflowrateisapplicablefromtheexistingpumpcurve.

2.Thenewrequiredheadshallnothigherthantheexistingpumpcanperform(atthatflow).Ifpumpheadisplenty,a
pressurereductiondevicemayberequirede.g.controlvalve,orifice(thismethodmightnotbeaopptimumsolutioninenergy
conservationpointofview).Anotherwayispumpimpellerchangegivingthepumpmoresuitabletothatsystem(youcan
consultwithmechanicalguyorpumpvendor).
3.Finally,notforgettocheckNPSHaofthenewsystem.
Hopethiscanhelpyou.
Posted03March201411:26PM

breizh
Ontopoftheinformationabove,considerthelinksunderneath:

http://www.pumpfunda...e.htm#download6(http://www.pumpfundamentals.com/downloadsfree.htm#download6)

http://www.mcnallyin...2html/27.html(http://www.mcnallyinstitute.com/02html/27.html)

Hopethishelps

Breizh

Posted03March201411:43PM

rahulavyas
Hi,

1.checkthepumpcurvesasprovidedbythevendorandcheckthesystemcurve

2.determinethefluidwhichneedstobepumpifthedesnsityisloweryouneedtocheckforthecalculationagain
3.Iftheheadisnotsufficienttrychangingtheimpellersize,whiledoingthislookatthemotororthedriveratingandpower,
useaffinitylawsforthesame
4.ifNPSHaislimitingtrytoreducethepressuredropacrosspipingorpossibilityofusinganinducerbeforetheimpeller

BacktoIndustrialProfessionals

7replies
425views

13Dec2015

13replies
568views

04Dec2015

2replies
515views

04Dec2015

17replies
504views

03Dec2015

8replies
1,033views

26Nov2015

FlowControlForPdPump
StartedbyGuest_farid.k_*,07Dec2015

PumpSuctionPressureEffect

HOT

StartedbyGuest_dineshperu_*,25Nov2015

ThermosiphonReboilerVelocityCriteria
StartedbyGuest_freeman_*,02Nov2015

ParallelPumpOperation
StartedbyGuest_Prasanjit_*,28Nov2015

PumpSelectionBasedOnViscosity
StartedbyGuest_Mahdi1980_*,28Sep2014

http://www.cheresources.com/invision/topic/20207criteriatodetermineadequacyofexistingpump/

HOT

2/3

12/23/2015

CriteriaToDetermineAdequacyOfExistingPumpIndustrialProfessionalsCheresources.comCommunity

Cheresources.comCommunity GeneralChemicalEngineeringForum IndustrialProfessionals

http://www.cheresources.com/invision/topic/20207criteriatodetermineadequacyofexistingpump/

3/3

Vous aimerez peut-être aussi