Vous êtes sur la page 1sur 40

Operation Manual

Scrubber
B-414

96701 en
Table of contents

Table of contents

1 About this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5


1.1 Reference documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
1.2 Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
2 Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
2.1 User qualification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
2.2 Proper use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
2.3 Improper use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
2.4 Warning notices used in this manual . . . . . . . . . . . . . . . . . . . . . . . . . .7
2.5 Product safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
2.5.1 Instrument-related hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
2.5.2 Other hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
2.5.3 Safety measures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
2.5.4 Safety elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
2.6 General safety rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
3 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.1 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.1.1 Standard instrument. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.1.2 Scrubber with condenser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.1.3 Scrubber with cold trap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.1.4 Scrubber complete with condenser and reaction stage . . . . . . . . . . . . . . . . 11
3.1.5 Standard accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.1.6 Optional accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.1.7 Upgrade. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.2 Technical data overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.3 Materials used. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.4 Recommended consumables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
4 Description of function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4.1 Functional principle of the Scrubber . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4.2 Scrubber capacity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
4.3 Condenser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.4 Cold trap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.5 External receiving vessel (option) . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Read this manual carefully before installing and running your system and note the safety precautions
in chapter 2 in particular. Store the manual in the immediate vicinity of the instrument, so that it can be
consulted at any time.
No technical modifications may be made to the instrument without the prior written agreement of
Buchi. Unauthorized modifications may affect the system safety or result in accidents.
This manual is copyright. Information from it may not be reproduced, distributed, or used for competi-
tive purposes, nor made available to third parties. The manufacture of any component with the aid of
this manual without prior written agreement is also prohibited.
If you need another language version of this manual, you can download it at
www.buchi.com.

3 B-414 Operation Manual, Version D


Table of contents

5 Putting into operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19


5.1 Installation site. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
5.2 General commissioning procedure for all Scrubber models . . . . . . . . . . . . . . 19
5.3 Commissioning the Scrubber with condenser / cold trap and reaction vessel . . . . . 20
5.4 External receiving vessel (optional). . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.5 Hose connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.5.1 Hose connections of the basic model . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.5.2 Hose connections for Scrubber with condenser / cold trap . . . . . . . . . . . . . . 23
5.5.3 Hose connections for Scrubber with condenser / cold trap and reaction vessel . . . . 24
5.6 Electrical connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
5.7 Preparing washing solutions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
5.7.1 Washing solutions for acidic vapors and gases . . . . . . . . . . . . . . . . . . . . 25
5.7.2 Washing solutions for alkaline vapors and gases . . . . . . . . . . . . . . . . . . . 25
5.7.3 Color indicator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
5.8 Filling up the prepared washing solution . . . . . . . . . . . . . . . . . . . . . . . . 26
6 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
6.1 Typical applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
6.2 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
7 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
7.1 Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
7.2 Glass parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
7.3 Tubes / tube connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
7.4 Sealing system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
7.4.1 Cleaning the seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
7.4.2 Replacing the seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
7.5 Washing insert . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
7.6 Washing solution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
7.7 Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
7.8 Power supply fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
7.9 Silencer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
7.10 Functional test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
7.11 Customer service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
8 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8.1 Malfunctions and their remedy . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
9 Shutdown, storage, transport and disposal . . . . . . . . . . . . . . . . . . . . . . . . 34
9.1 Storage and transport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
9.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
10 Spare parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
10.1 Spare parts on the exploded instrument view . . . . . . . . . . . . . . . . . . . . . 35
10.2 Miscellaneous . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
11 Declarations and requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
11.1 FCC requirements (for USA and Canada) . . . . . . . . . . . . . . . . . . . . . . . 37
11.2 Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

4 B-414 Operation Manual, Version D


1 About this manual

1 About this manual

This manual describes the Scrubber and provides all information required for its safe operation and to
maintain it in good working order.
It is adressed to laboratory personnel in particular.
NOTE
The symbols pertaining to safety (WARNINGS and ATTENTIONS) are explained in chapter 2.

1.1 Reference documents

For information on the Digest System, the Digest Automat, and the Digest Unit, please refer to the
corresponding manuals available in English, German, French, Italian and Spanish
• Digest System K-437, Operation Manual numbers 96760 - 96764
• Digest Automat K-438, Operation Manual numbers 96765 - 96769
• Digestion Unit K-424, Operation Manual numbers 96710 - 96714
• Digestion Unit K-435, Operation Manual numbers 96720 - 96724

1.2 Abbreviations

CR: Chloroprene Rubber


EPDM: Ethylene Propylene Dimonomer
FEP: Fluorinated Ethylene Propylene
FPM: Fluoroelastomer
pa: pro analysis
PA: Polyamides
PMMA: Polymethylmethacrylate
POM: Polyoxymethylene
PP: Polypropylene
PPS: Polyphenylenesulfide
PTFE: Polytetrafluoroethylene (Teflon)
PUR: Polyurethanes

5 B-414 Operation Manual, Version D


2 Safety

2 Safety

This chapter points out the safety concept of the instrument and contains general rules of behavior
and warnings from hazards concerning the use of the product.
The safety of users and personnel can only be ensured if these safety instructions and the safety-
related warnings in the individual chapters are strictly observed and followed. Therefore, the manual
must always be available to all persons performing the tasks described herein.

2.1 User qualification

The instrument may only be used by laboratory personnel and other persons who on account of
training or professional experience have an overview of the dangers which can develop when
operating the instrument.
Personnel without this training or persons who are currently being trained require careful instruction.
The present Operation Manual serves as the basis for this.

2.2 Proper use

The instrument has been designed and built for laboratories. It serves for the neutralization and
adsorption of gases that arise during chemical reactions and syntheses.
Only gases with known chemical composition may be drawn off.

2.3 Improper use

Applications not mentioned above are improper. Also, applications, which do not comply with the
technical data, are considered improper. In particular no gases with unknown chemical composition
may be drawn off.
The operator bears the sole risk for any damages caused by such improper use.
The following uses are expressly forbidden:
• Use of the instrument in rooms which require ex-protected instruments.
• Use on samples, which can explode or inflame (example: explosives, etc.) due to shock, friction,
heat or spark formation.
• Use in overpressure situations.
• Drawing off liquids.
• Drawing off solvents.
• Drawing off vapors of organic solvents.
• Use for cleaning of room air.

6 B-414 Operation Manual, Version D


2 Safety

2.4 Warning notices used in this manual

WARNING
Generally, the triangular warning symbol indicates the possibility of personal injury or even loss of life
if the instructions are not followed.

WARNING
Hot surface.

WARNING
Electrical hazard.

WARNING
Biohazard.

ATTENTION
With the general “Read this” symbol, ATTENTIONs indicate the possibility of equipment damage,
malfunctions or incorrect process results, if instructions are not followed.

NOTE
Useful tips for the easy operation of the instrument.

2.5 Product safety

The Scrubber is designed and built in accordance with current state-of-the-art technology. Neverthe-
less, risks to users, property, and the environment can arise when the instrument is used carelessly or
improperly.
The manufacturer has determined residual dangers emanating from the instrument
• if the instrument is operated by insufficiently trained personnel.
• if the instrument is not operated according to its proper use.
Appropriate warnings in this manual serve to make the user alert to these residual dangers.

2.5.1 Instrument-related hazards

Pay attention to the following safety notices:


WARNING
Potential implosion risk if used with damaged glassware.
• Beware of damaged or cracked glass parts.
WARNING
Potential explosion risk if solvent vapors accumulate within the instrument housing.
• Always use the instrument in a well ventilated area.
• Beware of damaged or cracked glass parts.
• Beware of the fire hazard.

7 B-414 Operation Manual, Version D


2 Safety

2.5.2 Other hazards

WARNING
Certain solvents in or in the vicinity of the Scrubber can form peroxides and/or are highly inflam-
mable.
• Always be aware of the explosion risk when working with hazardous substances or with
substances of unknown composition.
• Always provide a good ventilation within or in the vicinity of the system.
WARNING
Risk of implosion when operating the instrument with an external pump and excess pressure on the
overpressure valve.
• Always operated the instrument with the build-in pump and do not use an external pump.
WARNING
Risk of acidic vapors forming in the vicinity of the instrument when the washing solution is not
exchanged regularly.
• Always use a color indicator to judge the state of the washing solution and exchange the solution
as soon as the color indicator undergoes a color change.

2.5.3 Safety measures

Always wear personal protective equipment such as protective eye goggles, protective clothing and
gloves when working with the instrument.

2.5.4 Safety elements

• Overpressure valve
• The protective disc on top of the washing insert and the protective cover with the protective shield
to be mounted at the neutralization vessel protects operators from broken glass and solvent
splashes.

8 B-414 Operation Manual, Version D


2 Safety

2.6 General safety rules

Responsibility of the operator


The head of laboratory is responsible for training his personnel.
The operator shall inform the manufacturer without delay of any safety-related incidents which might
occur during operation of the instrument. Legal regulations, such as local, state and federal laws
applying to the instrument must be strictly followed.
Duty of maintenance and care
The operator is responsible for ensuring that the instrument is operated in proper condition only, and
that maintenance, service, and repair jobs are performed with care and on schedule, and by autho-
rized personnel only.
Spare parts to be used
Use only genuine consumables and genuine spare parts for maintenance to assure good system
performance and reliability. Any modifications to the spare parts used are only allowed with the prior
written permission of the manufacturer.
Modifications
Modifications to the instrument are only permitted after prior consultation with and with the written
approval of the manufacturer. Modifications and upgrades shall only be carried out by an authorized
Buchi technical engineer. The manufacturer will decline any claim resulting from unauthorized modifi-
cations.

9 B-414 Operation Manual, Version D


3 Technical data

3 Technical data

This chapter introduces the reader to the instrument specifications. It contains the scope of delivery,
technical data, requirements and performance data.

3.1 Scope of delivery

Check the scope of delivery according to the order number.


NOTE
For detailed information on the listed products, see www.buchi.com or contact your local dealer.

3.1.1 Standard instrument

Table 3-1: Standard instrument


Product Order number

B-414 Scrubber, standard


230 V / 50 Hz 37876
120 V / 60 Hz 37877
100 V / 50/60 Hz 37878
1 adsorption vessel, complete 38128
1 hose, adsorption / pump 37885

3.1.2 Scrubber with condenser

Table 3-2: Scrubber with condenser


Product Order number

230 V / 50 Hz 37882
120 V / 50 Hz 37883
100 V / 60 Hz 37884
1 condenser unit 37775
3 tube connectors, bent with screw cap 32885
1 silicone hose Ø 6/9 04133
1 spring ring 37872
1 holder ring for receiving vessel 36709
1 seal for receiving vessel 37873
1 receiving vessel 1.2 l 37776
1 hose, condenser / lye 37888
1 adsorption vessel, complete 38128
1 hose, adsorption / pump 37885

10 B-414 Operation Manual, Version D


3 Technical data

3.1.3 Scrubber with cold trap

Table 3-3: Scrubber with cold trap


Product Order number

230 V / 50 Hz 37879
120 V / 50 Hz 37880
100 V / 50/60 Hz 37881
1 cold trap complete 38083
3 tube connectors, bent with screw cap 32885
1 receiving vessel 1.2 l 37776
1 spring ring 37872
1 holder ring for receiving vessel 36709
1 seal for receiving vessel 37873
1 hose, condenser / lye 37888
1 adsorption vessel, complete 38128
1 hose, adsorption / pump 37885

3.1.4 Scrubber complete with condenser and reaction stage

Table 3-4: Scrubber complete with condenser and


reaction stage
Product Order number

230 V / 50 Hz 37988
120 V / 50 Hz 37989
100 V / 50/60 Hz 37990
1 condenser unit 37775
3 hose connections bent with screw caps 32885
1 silicone hose Ø 6/9 04133
1 spring ring 37872
1 holder ring for receiving vessel 36709
1 seal for receiving vessel 37873
1 receiving vessel 1.2 l 37776
1 hose, condenser / lye 37888
1 adsorption vessel, complete 38128
1 hose, adsorption / reaction 37887
1 reaction stage 37956

11 B-414 Operation Manual, Version D


3 Technical data

3.1.5 Standard accessories

Table 3-5: Standard accessories


Product Order number

1 neoprene hose 10021


1 power cable
Type CH 10010
Type Schuko / Japan 10016
Type GB 17835
Type USA 33763
Type AUS 17836
Operation Manual:
English 96701
German 96700
French 96702
Italian 96703
Spanish 96704

3.1.6 Optional accessories

Table 3-6: Optional accessories


Product Order number

1 condenser unit 37775


1 cold trap complete 38083
1 condensate drain 37785
1 reaction vessel 37797
1 lip gasket, acid-resistant 38064
1 hose, adsorption / pump 37885
1 hose, reaction / pump 37886
1 hose, adsorption / reaction 37887
1 hose, condenser / washing solution 37888
1 connection cable B-414 / Digestion 14738
Units, Control Unit
Set large receiving vessel 4 l 48668

12 B-414 Operation Manual, Version D


3 Technical data

3.1.7 Upgrade

Table 3-7: Upgrade possibilities


Product Order number

1 condenser with receiving vessel 1.2 l, 37954


complete
Cold trap with receiving vessel 1.2 l, 37955
complete
1 reaction stage, complete 37956

3.2 Technical data overview

Table 3-8: Technical data


Scrubber Unit B-414

Dimensions (L x H x D) 260 x 450 x 480 mm


Weight 13 kg
Power system voltage / frequency 230 V ± 10 % / 50 Hz 140 W
120 V ± 10 % / 60 Hz 100 W
100 V ± 10 % / 50/60 Hz 100 W
Ambient temperature For indoor use only, altitude up to 2000 m above seal
level, maximum relative humidity 80 %, 5 - 40 °C
Pump suction capacity 34 l/min
Overvoltage category II
Pollution degree 2
Power consumption 200 W
Current consumption (230 V) 1.5 A

3.3 Materials used

Table 3-9: Materials used


Component Material designation

Housing PUR
Minor hardware PP, PA, POM
Lip gasket acid- / lye-resistant FPM, EPDM
Gasket PTFE, CR
Protective disc PMMA
Glass parts Borosilicate 3.3
Pump PPS, CR, FPM
Hoses CR, FEP

13 B-414 Operation Manual, Version D


3 Technical data

3.4 Recommended consumables

Table 3-10: Active charcoal for adsorption vessel


Product Order number Fluka / Merck

Fluka, purum p.a. 4 - 8 mm 05110


Merck, granulated 102518

Table 3-11: Color indicator for washing solution


Product Order number Merck

Bromothymol blue, Merck 3026

14 B-414 Operation Manual, Version D


4 Description of function

4 Description of function

This chapter explains the basic principle of the instrument, shows how it is structured and gives a
functional description of the assemblies.

The pump draws off the gases and vapors produced in chemical reactions via a condenser or a cold
trap providing a receiving vessel underneath.
The condensation stage is used as a preliminary extractor for vapors, water steam (to prevent
warming or an increase in volume of the washing solution) and for the liquids carried along with them,
thus extending the service life of the neutralization stage.
The acid or alkaline gases are washed and neutralized in the neutralization stage.
The next stage, the adsorption stage, holds back most of the undesired particles by means of
granules of activated charcoal or a universal adsorption granulate. It also enables the aerosols to
recondensate.
In the reaction stage that follows specific redox reactions are accomplished.
The built-in overpressure valve makes sure that a certain pressure limit is not exceeded. The used air
is directly lead into an exhaust or into the open air through a silencer.

4.1 Functional principle of the Scrubber

2
4
3

1
5

 Receiving vessel  Adsorption vessel


 Condenser (or cold trap)  Neutralization vessel
 Reaction tubelet
Fig. 4.1: Overview over the Scrubber

15 B-414 Operation Manual, Version D


4 Description of function

Adsorption

4
1
PUMP

2
5

Condensation Neutralisation Reaction stage

 Condenser or cold trap  Adsorption vessel with adsorbents


 Receiving vessel  Reaction stage
 Neutralization vessel with washing solution  Fume exhaust pump
Fig. 4.2: Functional principle of the Scrubber

Condensation stage
• Condensation of vapors
• Condensation of water steam (prevention of warming or an increase in volume of the washing solu-
tion)
• Condensation of the liquids carried along
Neutralization stage
• Neutralization of acid or alkaline gases
Adsorption stage
• Specific adsorptions and retention of particles (using granules of activated charcoal or a universal
adsorption granulate)
• Recondensation of aerosols
Reaction stage
• Specific reactions (e.g., redox reactions)

4.2 Scrubber capacity

The suction capacity of the Scrubber B-414 is designed for Digestion Units with a maximum of 20
sample tubes.
Connection examples:
• Connection of up to two Digestion Units K-424 (6 places each)
• Connection of one Digestion Unit K-435 (12 places)
• Connection of one Digest Automat K-438 (20 places)
• Connection of one Digest System K-437 (20 places)

16 B-414 Operation Manual, Version D


4 Description of function

4.3 Condenser

1
3 2

 Cooling water out  Emission in (connection to emission source)


 Connection to neutralization stage  Cooling water in
Fig. 4.3: Connections of the condenser

4.4 Cold trap

 Emission in (connection to emission source)  Connection to neutralization stage


Fig. 4.4: Connections of the cold trap

17 B-414 Operation Manual, Version D


4 Description of function

4.5 External receiving vessel (option)

A large receiving vessel for up to 4 l is optionally available. It serves for the digestion of high volumes of
water samples.

Fig. 4.5: External receiving vessel

18 B-414 Operation Manual, Version D


5 Putting into operation

5 Putting into operation

This chapter describes how the instrument is installed and gives instructions on initial startup.
NOTE
Inspect the instrument for damages during unpacking. If necessary, prepare a status report immedia-
tely to inform the postal company, railway company or transportation company.
Remove the transprotation lock at the bottom of the instrument.
Keep the original packaging for future transportation.

5.1 Installation site

Install the instrument on a clean, flat and stable base.


ATTENTION
To ensure the instrument safety do not place any object on top of it.

ATTENTION
Place the Scrubber B-414 on the left side of a digestion unit (e.g. Digestion Unit K-424, K-435,
Digest System K-437 or Digest Automat K438). The Scrubber ventilation is located on the left side. In
case the Scrubber is placed on the right side of another unit, cool air will hit the digestion sample and
cool it down, so that no digestion can take place.

5.2 General commissioning procedure for all Scrubber models

To commission the Scrubber B-414, proceed as follows:


• Apply the protective cover and shield to the neutralization vessel.
• Make sure that the silencer is filled with cotton wool and install it.
• Check the glass for flaws and cracks.
• Check the seals and gaskets (embrittlement, scratches). If they are not OK, take them out and
replace them (see also chapter 7).
• Carefully insert the glass parts using a clamping ring (without pressure from above). Otherwise
there is a risk of damaging the glassware.
NOTE
When you carry out Kjeldahl digestions, the suction capacity might become too high. Therefore we
recommend to fill activated charcoal into the adsorption vessel and to add glass wool at both ends.
The glass wool prevents charcoal from being drawn into the vacuum pump. The activated charcoal
should be grainy with a particle size of 2 to 6 mm.

Fig. 5.1: Adsorption vessel with activated charcoal and glass wool

19 B-414 Operation Manual, Version D


5 Putting into operation

5.3 Commissioning the Scrubber with condenser / cold trap and reaction vessel

To prepare the complete Scrubber model for operation, proceed as follows:


• Insert the white PTFE gasket into the holder ring for the receiving vessel, so that it fits properly into
it on both sides.
• Press the holder ring into the gap provided for condenser / cold trap and receiving vessel.
• Apply the spring ring to the bottom of the condenser / cold trap (the cooling water / contaminated
air inlet must be at the bottom) and introduce the condenser into the holder ring.
• Screw the receiving vessel counterclockwise into the holder ring underneath the condenser.
 Spring ring
 Holder ring
 Gasket PTFE

3 1

Fig.5.2: Connection between condenser and receiving vessel

• Insert the reaction vessel into the housing from below.


• Insert the introduction tube of the reaction tubelet into the reaction vessel and screw it in tightly.

20 B-414 Operation Manual, Version D


5 Putting into operation

5.4 External receiving vessel (optional)

To commission the optional external receiving


vessel, proceed as follows:
• Connect the one end of the adapter (FEP
hose) to the bottom of the condenser.
• Connect other side of the adapter to the
external receiving vessel and fasten the
connection with the black screw caps.

Fig.5.3: Connecting the external receiving vessel

ATTENTION
Do not use plastic tanks for the collection of condensate but only original glass vessels from Buchi.
• The diameter of the connection between the outlet and the receiving vessel must not be less than
10 mm.
• The materials used must be resistant to the condensate and must withstand a vacuum of 100
mbar.

5.5 Hose connections

NOTE
Use clips and cable ties where necessary to secure the cables in place.

5.5.1 Hose connections of the basic model

The basic model consists of the neutralization and the adsorption vessel.
To establish the hose connections, proceed as follows:
• Connect the adsorption vessel to the distribution head and secure with tube connectors GL-14 at
both ends.
• Connect the emission source via a Woulff bottle to the neutralization vessel.

21 B-414 Operation Manual, Version D


5 Putting into operation

3 1
2

4
5

 Neutralization stage  Distribution head


 Connection of the neutralization vessel  Silencer
 Adsorption vessel
Fig. 5.4: Hose connections of the basic model

22 B-414 Operation Manual, Version D


5 Putting into operation

5.5.2 Hose connections for Scrubber with condenser / cold trap

To establish the hose connections, proceed as follows:


• Put tube connectors GL-14 on all PTFE hoses.
• Connect the emission source to the condenser / cold trap inlet (position  in Fig. 5.2 ).
• Connect the condenser / cold trap outlet (position  in Fig. 5.2) to the neutralization vessel.
• Connect the adsorption vessel to the distribution head.

1
2

10
3

7 9
6 8

4
5

 Neutralization stage  Inlet from emission source


 Adsorption vessel  Outlet to neutralization vessel
 Reaction stage  Cooling water inlet (bottom)
 Distribution head Cooling water outlet (top)
 Silencer
Condenser
Fig. 5.5: Hose connections for Scrubber with condenser / cold trap

23 B-414 Operation Manual, Version D


5 Putting into operation

5.5.3 Hose connections for Scrubber with condenser / cold trap and reaction vessel

To establish the hose connections, proceed as follows:


• Put tube connectors GL-14 on all PTFE hoses.
• Connect the emission source to the condenser / cold trap inlet (position  in Fig. 5.3 ).
• Connect the condenser / cold trap outlet (position  in Fig. 5.3) to the neutralization vessel.
• Connect the adsorption vessel to the top of the reaction tubelet.
• Connect the reaction tubelet (connection at the front) to the distribution head

2 1

10

3 9
6 7
8

4
5

 Neutralization stage  Inlet from emission source


 Adsorption vessel  Outlet to neutralization vessel
 Reaction stage  Cooling water inlet (bottom)
 Distribution head Cooling water outlet (top)
 Silencer
Condenser
Fig. 5.6: Hose connections for Scrubber with condenser / cold trap and reaction vessel

24 B-414 Operation Manual, Version D


5 Putting into operation

5.6 Electrical connections

ATTENTION
Make sure that the voltage on the socket corresponds to the voltage given on the type plate of the
instrument.
Always connect the instrument to an earthed socket. External connections and extension cables
must be provided with an earthed conductor lead (3-pole couplings, cable or plug equipment) as the
mains lead has a molded plug, thus avoiding risks due to inadvertent defective wiring.

Make sure that no electric sparks form in the instrument or its surroundings as they might damage
the instrument.
Connect the Scubber B-414 to the mains with the power cord contained in the scope of delivery.
To start the Scrubber automatically at the same time the digestion process starts, connect it to the
Control Unit B-436, to a Digest System K-437 or to a Digest Automat K-438 with the optional connec-
tion cable.

5.7 Preparing washing solutions

ATTENTION
Always wear personal protective equipment such as protective eye goggles, protective clothing and
gloves when working with washing solutions.

5.7.1 Washing solutions for acidic vapors and gases

• Sodium hydroxide 8-10 %, max. 20 %


• Sodium carbonate
– dissolve 600 g Na2CO3 in 3 l distilled warm water, or
– dissolve 1.7 kg Na2CO3 · 10H2O in 3 l distilled warm water

5.7.2 Washing solutions for alkaline vapors and gases

• Hydrochloric acid, max. 15%


• Sulphuric acid, max. 20%
Depending on the area of application, it is recommended to use different washing solutions or concen-
trations. The B-414 Scrubber is supplied ex works with a lye-resistant lip gasket. For operating with
acid washing solutions, an acid-resistant lip gasket should be used.

5.7.3 Color indicator

A color indicator is added to the washing solution to assess its washing power visually as well.
We recommend to use 100 mg of color indicator for 3 l of washing solution.
Bromothymol blue serves as a standard indicator. The transition area here is between pH 6.0 to 7.6.
Thus the fresh solution has a blue color while the neutralized or acidic solution has an orange yellowish
color.
Depending on the application purpose, other suitable color indicators should be used.

25 B-414 Operation Manual, Version D


5 Putting into operation

5.8 Filling up the prepared washing solution

To fill up the washing solution, proceed as follows:


• Remove the adsorption vessel  by gently pulling it upwards.
• Loosen the tube connector GL-14  at the neutralization vessel and pull off the hose.
• Remove the protective cover  with the protective shield.
• Remove the protective disc with the washing insert  from the neutralization vessel.
• Carefully pour the washing solution into the washing vessel and fill up to the wavy maximum filling
mark.
• Reassemble the instrument in the reverse order.

5
4

 Adsorption vessel  Washing insert


 Nut GL-14  ON/OFF switch
 Protective cover with protective shield
Fig. 5.7: Filling up the washing solution

NOTE
For information on how and when to exchange the washing solution, see chapter 7.6

26 B-414 Operation Manual, Version D


6 Operation

6 Operation

This chapter gives examples of typical instrument applications and instructions on how to operate the
instrument properly and safely.
WARNING
Risk of injury.
• Never operate the instrument when glassware is damaged.
ATTENTION
Switch on the B-414 before a connected instrument produces gases.

6.1 Typical applications

Table 6-1: Typical applications


Gases and vapors Chemical formula Neutralization (stage 2) Specific reactins (stage 4)

Kjeldahl digestions SO2, H2SO4 saturated soda / NaOH


8 - 10 % (max. 20 %)
Sulfur dioxide SO2 saturated soda / NaOH
8 - 10 % (max. 20 %)
Sulfuryl chloride SO2Cl2 NaOH 8 - 10 % (max. 20 %)
Hydrochloric or hydro- HCI, HBr NaOH 8 - 10 % (max. 20 %)
bromic acids
Thionyl chloride SOCl2 NaOH 8 - 10 % (max. 20 %)
Cyanuric chloride C3N3Cl3 NaOH 8 - 10 % (max. 20 %)
Carbonic acid chloride R-COCI NaOH 8 - 10 % (max. 20 %)
Phosgene COCI2 NaOH 8 - 10 % (max. 20 %)
Ammonia NH3 HCI max. 15 % / H2SO4 max. 20 %
Nitrous oxides (nitrous NOX NaOH 20 % FESO4 saturated
gases)
Nitric acid / aqua regia
Chlorine, bromine, iodine Cl2, Br2, J2 NaOH 8 - 10 % (max. 20 %) FESO4 saturated
Thiophenols Ar-SH NaOH 8 - 10 % (max. 20 %) KMnO4 saturated
Thioalcohols, mercaptan R-SH NaOH / javelle water KMnO4 saturated
Hydrogen sulphide H 2S NaOH 8 - 10 % (max. 20 %) KMnO4 saturated
Carbon disulphide CS2 NaOH 8 - 10 % (max. 20 %) KMnO4 saturated
Prussic acid HCN NaOH 8 - 10 % (max. 20 %) KMnO4 saturated

27 B-414 Operation Manual, Version D


6 Operation

6.2 Operation

• Switch on the power switch .


• Make sure that the cooling water flow rate
does not exceed 60 l/h.
• The suction performance can be regulated
during operation by drilling a 0.1 - 0.3 mm
wide hole in the screw cap GL-14  (e.g.
2
when samples are getting dry).
• Carry out a functional test as described in
chapter 7.10.

Fig. 6.1.: Operation

28 B-414 Operation Manual, Version D


7 Maintenance and repairs

7 Maintenance

This chapter gives instructions on all maintenance work to be performed in order to keep the instru-
ment in good working condition.
WARNING
Electrical hazard:
• Prior to all maintenance work on the instrument switch off the power supply and remove all
sources of flammable vapor.
ATTENTION
Always wear personal protective equipment such as protective eye goggles, protective clothing and
gloves when maintaining the instrument.

7.1 Housing

Check the housing for defects (switches, plugs) and clean it regularly with a damp cloth.
ATTENTION
Never use solvents as cleaning agents as these might damage the instrument.

7.2 Glass parts

The glass parts can be taken out and cleaned with commercially available cleaning agents or in an
ultrasonic bath. After the glass parts have been cleaned and fully dried, check each part visually for
cracks, scratches and for any parts or sections that might have splintered off. Take out and replace
any damaged glass parts.

7.3 Tubes / tube connectors

Visually examine the tube connections regularly. When tubes become cracked and brittle, replace
them with new tubes.
Grease all joints on the condenser side regularly to achieve optimum tightness of the system.
Flush out the tubes regularly with water or ethanol.

7.4 Sealing system

ATTENTION
When removing and reinstalling the seals and gaskets, make sure not to damage them. Always move
them perpendicularly to the axis of the glass parts and ensure no damage occurs to the sealing lip.
Never apply grease to the seals and never touch them with sharp object, otherwise they will get
damaged.

29 B-414 Operation Manual, Version D


7 Maintenance and repairs

7.4.1 Cleaning the seals

To prolong the lifetime of the seals, rinse them regularly with water, especially if working with crystalline
products. Afterwards, dry them with a solft cloth. To remove the seals, see Fig. 7.1.

7.4.2 Replacing the seals

Seals are subject to wear and tear, thus you should check them regularly and replace them, if neces-
sary, e.g. if they do not pass the functional test described in chapter 7.8 anymore.
We recommend to replace the seals as follows:

Table 8-1: General malfunction and their remedy


Position in Fig. 9.1 Order no. Description Replacing interval

-- 40029 Set of seals EPDM for tube connectors once a year


8 37928 O-ring to adapter (37777) once a year
13 03575 Gasket SVL 42 x 30 PTFE once a year
17 03576 Gasket SVL 22 x 16 PTFE once a year
19 38225 Hose seal once a year
23 37873 Seal for receiving vessel once a year
34 37925 Gasket ring once a year
38 37871 Silencer unit once a year

7.5 Washing insert

The washing insert must be cleaned from time to time and the lip gasket must be replaced when
brittle.

6 7

2
3

2
1
 Nut M20  Lip gasket
 Swirl disc  Protective disc
 Spacer tube  Tube connector adapter M20 GL-14
 Swirl disc holder
Fig. 7.1. Exploded view of the washing insert

30 B-414 Operation Manual, Version D


7 Maintenance and repairs

To (re)assemble the washing insert, proceed as follows:


• Insert the lip gasket  into the protective disc .
• Place the protective disc  on the swirl disc holder .
• Screw on the adapter  and tighten it.
• Insert the first swirl disc  .
• Insert the spacer tube .
• Insert the second swirl disc .
• Screw the washing insert into the adapter .
• Introduce the washing insert into the neutralisation vessel.
• Put on the protective disc.
• Put on the protective cover with shield and center the neutralization vessel.

7.6 Washing solution

Used washing solutions may impair the functionality of the B-414 Scrubber especially in the range of
the neutralization point as a result of strong foaming. Changing the washing solution in appropriate
time (when the color indicator ongoes a color change) keeps the adsorption stage and/or reaction
stage from getting soiled and prevents the possibility of the pump getting damaged. For a discription
of how to prepare and fill up the washing solution, see chapter 5.7.
NOTE
Make sure to dispose of the used washing solution according to your laboratory guidelines.

7.7 Pump

To flush the pump, proceed as follows:


2 • Take off the silencer  and flush out the
pump with distilled water  through the
secondary air valve .
• Switch on the instrument and collect the
waste water in a suitable vessel .

1 4 3

Fig. 7.2: Flushing the pump

31 B-414 Operation Manual, Version D


7 Maintenance and repairs

7.8 Power supply fuses

To replace the power supply fuses, proceed as


follows:
• Pull out the power supply cable.
• Remove the fuse holder .
• Replace the defective fuse with a new fuse 
of the same type:
– 100 V: T 2.0 A L 250 V
2
– 120 V: T 1 A L 250 V
1 – 230 V: T 1 A L 250 V
• Put the fuse holder back.

Fig. 7.3: Replacing the power supply fuses

7.9 Silencer

Replace the silencer once a year.

7.10 Functional test

To check whether the overpressure valve functions properly, screw off the left tube connector at the
distribution head and put a finger on the opening. After the overpressure valve has switched, a change
of sound is audible.
The system is tight, when the washing solution in the neutralization vessel bubbles when the instru-
ment is switched on.

7.11 Customer service

Only authorised service personnel are allowed to perform repair work on the instrument. These
persons have a comprehensive technical training and knowledge of possible dangers which might
arise from the instrument.
Addresses of official Buchi customer service offices are given on the Buchi website under:
www.buchi.com. If malfunctions occur on your instrument or you have technical questions or applica-
tion problems, contact one of these offices.
The customer service offers the following:
• Spare part delivery
• Repairs
• Technical advice

32 B-414 Operation Manual, Version D


8 Troubleshooting

8 Troubleshooting

This chapter helps to resume operation after a minor problem has occurred with the instrument. It lists
possible occurrences, their probable cause and suggests how to remedy the problem.
The troubleshooting table below lists possible malfunctions and errors of the instrument. The operator
is enabled to correct some of those problems or errors by him/herself. For this, appropriate corrective
measures are listed in the column “Corrective measure”.
The elimination of more complicated malfunctions or errors is usually performed by a Buchi technical
engineer who has access to the official service manuals. In this case, please refer to your local Buchi
customer service agent.

8.1 Malfunctions and their remedy

Table 8-1: General malfunction and their remedy


Malfunction Possible cause Corrective measure
B-414 does not work No mains connection Check whether the instrument is
Fuses defective connected to the mains
Replace the defective fuses
Mains switch defective Contact the Buchi customer service
Pump does not work Wiring defective Contact the Buchi customer service
Pump defective
Fumes are not exhausted during Suction system leaking Tighten the tube connections
extraction (Scrubber suction capacity Hose bent Check the hoses
too weak) Adsorption vessel clogged Check the adsorption vessel
Washing solution dirty Exchange the washing solution
Adsorbents clogged Renew the adsorbents
Pump dirty Clean the pump
Silencer unit clogged Replace the silencer unit
Overpressure valve dirty Contact the Buchi customer service
Fumes are exhausted too fast during Suction system clogged Check all stages and the connected
extraction (Scrubber suction capacity digestion unit as well
too strong) Adsorbents clogged Exchange the adsorbents
Silencer unit defective Replace the silencer unit
Overpressure valve defective Contact the Buchi customer service
Washing solution turns yellow Washing solution dirty Exchange the washing solution

33 B-414 Operation Manual, Version D


9 Shutdown, storage, transport and disposal

9 Shutdown, storage, transport and disposal

This chapter instructs how to shut down the instrument, how to pack it for storage or transport, and
specifies the storage and shipping conditions.

9.1 Storage and transport

WARNING
Biohazard:
• Remove all dangerous substances from the instrument and clean it thoroughly.

Store and transport the instrument in its original packaging.

9.2 Disposal

To dispose of the instrument in an environmentally friendly manner, a list of materials is given in


chapter 3. This helps to ensure that the components are separated and recycled correctly. Make
especially sure to dispose of the gas springs appropriately.
Please follow valid regional and local laws concerning disposal.

34 B-414 Operation Manual, Version D


10 Spare parts

10 Spare parts

This chapter lists spare parts, accessories, and options including their ordering information.
Order the spare parts from Buchi. Always state the product designation and the part number when
ordering spare parts.
Use only genuine Buchi consumables and genuine spare parts for maintenance and repair to assure
good system performance and reliability. Any modifications to the spare parts used are only allowed
with the prior written permission of the manufacturer.

10.1 Spare parts on the exploded instrument view

29 21
26

28
22
18 20
23
24 19
30
27 17 9
12 35
36
25 38
13 11 10
37 14 9
15
16

6 31
39
7
8

33
5 34

4
3 32

Fig. 10.1: Spare parts on the exploded instrument view

35 B-414 Operation Manual, Version D


10 Spare parts

Table 10-1: Spare parts on the exploded instrument view


Position Product Order Position Product Order number
number
1 Protective shield 37820 20 Hose adsorption / pump 37885
2 Neutralization vessel 37786 21 Condenser complete, including: 38022
3 Lip gasket lye-resistant EPDM 37874 22 - Spring ring 37872
4 Lip gasket acid-resistant FPM 38064 23 - Gasket 37873
5 Swirl disc 37821 24 - Holder ring 36709
6 Set of 4 tube connectors with cap 40295 25 Receiving vessel, 1.2 l 37776
bent FPM
7 Adapter for GL-14 37777 26 Hose condenser / washing solution 37888
8 O-ring to adapter (37777) 37928 27 Cold trap 37781
9 Screw cap GL-14 (set of 10) 41956 28 O-ring FPM for cold trap 38067
- Set of seals EPDM for tube 40029 29 Trap unit for cold trap 37782
connectors (set of 10)
10 Hose seal 38225 30 Connector GL-14 straight 37642
11 Screw cap GL-14 40624 31 Introduction tube assembly 37778
12 Adsorption vessel 37774 32 Reaction vessel, 1.0 l 37797
13 Gasket SVL 42 x 30 PTFE 03575 33 Screw cap SVL 42 03551
14 Adapter complete for adsorption 37971 34 Gasket ring 37925
vessel
15 O-ring 47.2 for adsorption vessel 37857 35 Hose adsorption / reaction 37887
16 O-ring 39.7 for adsorption vessel 38068 36 Hose reaction / pump 37886
17 Gasket SVL 22 x 16 PTFE 03576 37 Condensate drain 37785
18 Adapter SVL 22 / GL14, complete 37972 38 Silencer unit 37871
19 Seal for FEP tube 38225 39 Distribution head, complete 37952

10.2 Miscellaneous

Table 10-2: Miscellaneous


Product Order number

Set of sealings FPM (10 pieces) 40040


Axial flow fan B-414 38026

36 B-414 Operation Manual, Version D


11 Declarations and requirements

11 Declarations and requirements

11.1 FCC requirements (for USA and Canada)

English:
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to both Part 15 of the FCC Rules and the radio interference regulations of the Canadian
Department of Communications. These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used
in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
Français:
Cet appareil a été testé et s'est avéré conforme aux limites prévues pour les appareils numériques
de classe A et à la partie 15 des réglementations FCC ainsi qu’à la réglementation des interférences
radio du Canadian Department of Communications. Ces limites sont destinées à fournir une protec-
tion adéquate contre les interférences néfastes lorsque l’appareil est utilisé dans un environnement
commercial.
Cet appareil génère, utilise et peut irradier une énergie à fréquence radioélectrique, il est en outre
susceptible d’engendrer des interférences avec les communications radio, s’il n’est pas installé et
utilisé conformément aux instructions du mode d’emploi. L’utilisation de cet appareil dans les zones
résidentielles peut causer des interférences néfastes, auquel cas l’exploitant sera amené à prendre les
dispositions utiles pour palier aux interférences à ses propres frais.

37 B-414 Operation Manual, Version D


11 Declarations and requirements

11.2 Declaration of conformity

We BÜCHI Labortechnik AG
do hereby declare on our responsibility that the product:

Scrubber B-414

which is the object of this certification, is in accordance with the following norms:

EN 61010-1:2001 (~ IEC 61010-1) Safety requirements for electrical equipment for measurement,
control, and laboratory use
Part 1: General requirements

EN 55011:1998 + A1:1999 (IEC/CISPR 11:1997, modified + A1:1999) Industrial, scientific and


medical (ISM) radio-frequency equipment - Radio disturbance characteristics - Limits and methods of
measurement

EN 60335-1:2002: Household and similar electrical appliances - Safety -


Part 1: General requirements

EN 6100-3-2:2000 Limits for harmonic current emissions

EN 6100-3-3:2000 Limitations of voltage fluctuations and flicker

In accordance with the regulations of the EU guidelines

73/23/EEC (electrical operating equipment/low-voltage guidelines)


89/336/EEC (electromagnetic compatibility)

Flawil, 12.01.06
BÜCHI Labortechnik AG
Meierseggstrasse 40
Postfach
CH-9230 Flawil 1
Switzerland
Tel.: +41 (0)71 394 63 63 Guido Worch
Fax: +41 (0)71 394 65 65 Quality Manager
buchi@buchi.com
www.buchi.com

38 B-414 Operation Manual, Version D


BÜCHI Labortechnik AG
CH-9230 Flawil 1 / Switzerland
T +41 71 394 63 63
F +41 71 394 65 65 096701

www.buchi.com Quality in your hands

Vous aimerez peut-être aussi