Vous êtes sur la page 1sur 61

Internal

OTD203210 OptiX iManager T2000LCTV2 Operation and Maintenance


for SDH/OSN Equipment
ISSUE 1.00

HUAWEI TECHNOLOGIES CO., LTD.

www.huawei.com

All rights reserved

The slides are drafted according to the


<T2000 LCT User Manual>.
Please refer to <T2000 LCT User Manual>
&
<OSN3500&2500&1500
Service
Configuration Guide>for details

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 2

Upon completion of this course, you will be able to:


[ Understand the menus of OptiX iManager T2000 LCT
[ Create Topology including create NE/Link/NM
[ Perform the NE configuration, board configuration, service
dispatching and protection configuration for equipment via
OptiX iManager T2000 LCT
[ Perform the routine maintenance via T2000 LCT

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 3

Chapter 1 Quick Start


Chapter 2 Configure Services
Chapter 3 Maintenance

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 4

Quick Start

Starting and Shutting


Down the T2000-LCT

Opening/Closing the Online Help

Selecting Operation Objects

Setting Parameters in the List

Operation Precautions

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 5

Quick Start

NE

T2000

NE

GNE

NMS

HUB
NE
T2000LCT

HUB

IP address :129.9.X.X
Submask : 255.255.0.0

IP address :129.9.0.ID
Submask : 255.255.0.0

The IP address of the computer and the NE


should be in the same IP network segment.
HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 6

Starting/Exiting the T2000 Server


Starting the T2000-LCT Server
Default User name: admin
Default password: T2000

HUAWEI TECHNOLOGIES CO., LTD.

Exiting the T2000-LCT


Server from System Monitor

All rights reserved

Page 7

Opening/Closing the Online Help


Opening the Online Help
Select [Help/Help Topic] from the Main Menu Support <F1> as a function interface

Closing the Online Help


Step

Action

Close the active dialog boxes.

Close the active pop-up windows.


& Note:

To close the pop-up window, click outside it in the help window.


3

Click

of the help window.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 8

Selecting Operation Objects


1, Select an operation object from the upper left pane of the NE Explorer: NE or board;
2, Select a function from the Function Tree. Any folder (branch) in the Function Tree can be
expanded by clicking
to the left of the folder;
3, Click the double-right-arrow button to add the object to the operation interface on the right
side.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 9

Setting Parameters in the List


1, Select an operation object;
2, Double-click the column to be set in the list to display the pull-down combo box or
edit box;
3, Another way is to right-click the item to modify and select the appropriate item from
the shortcut menu.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 10

Operation Precautions
l

It is recommended to query the latest data from NE before


setting parameters.

Usually, when a dangerous operation is performed, the T2000LCT will ask for confirmation.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 11

Chapter 1 Quick Start


Chapter 2 Configure Services
Chapter 3 Maintenance

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 12

Configuring Service
Stage

Description

Creating an NE

Configuring the NE

Creating SDH
Services

Creating Line Services


Creating Unidirectional PP Ring Services
Creating Bidirectional MSP Ring Services
Creating Unidirectional MSP Ring Services
Creating SNCP Services
Changing an SNCP Service to a Normal Service
Changing a Normal Service to an SNCP Service

Creating Ethernet
Services

Creating Transparent Transmission Services Over Ethernet


Creating Convergent Transmission Services Over Ethernet
Creating EPL Services
Creating EVPL Services
Creating EPLn Services
Creating EVPLn Services
Creating RPR EVPL Services
Creating RPR EVPLn Services

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 13

Create NE
1. Click <Create> in the NE
Information Management.
2. Select the NE type from the
Create Topology Object dialog
box and enter the attribute
information of the NE. (Default NE
user of the T2000-LCT: lct; default
password: password. )

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 14

Configuring NE
1. Click <Configuration> in the NE Information Management.
2. Select Manual Configuration and click Next.
3. The Confirm dialog box is displayed. Click <OK>. The NE Configuration Wizard
dialog box is displayed.
4. Set the NE attributes and click <Next>. The NE panel is displayed.
5. Click <Query Physical Slot> to upload the data to the physical slot from the NE side.
6. After all the boards have been created, click <Next>. Then, click <Finish>

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 15

Configuring SDH Service

Configuring SDH/PDH service

..
HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 16

Configuring SDH Service


Creating a Bidirectional
Line/PP/MSP Ring Service
Clock
1. In the NE Explorer, click the NE
and select [Configuration/SDH
Service Configuration] from the
Function Tree.
2. Click <Query> to query the SDH
service information from the NE,
then click <Create>. The Create
SDH Service dialog box is
displayed
3. Configure the parameters of the
source and the sink. Click <OK>.
HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 17

Configuring SDH Service


Creating an SNCP Service--Configuring Dual-fed Services
1. In the NE Explorer, click the NE and select [Configuration/SDH Service Configuration] from
the Function Tree.
2. Click <Query> to query the SDH service information from the NE.
3. Click <Create>. The Create SDH Service dialog box is displayed.
4. Configure the service from the tributary board to the east and west line board. Click <OK>

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 18

Configuring SDH Service


Creating an SNCP Service--Creating a Selectively Received Service
1. In the NE Explorer, click the NE and select [Configuration/SDH Service Configuration]
from the Function Tree.
2. Click <Create SNCP>. The Create SNCP Service dialog box is displayed.
3. Configure the working and protection service. Click <OK> .

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 19

Configuring Ethernet Service


Configuring EPL service

Configuring EVPL service

Ethernet Service type

Configuring EPLn service

Configuring EVPLn service

Configuring RPR EVPL/EVPLn

service
..
HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 20

Configuring Ethernet Service

Configuring EPL service

Procedure

Action

Configuring Port Attributes and Binding Paths of an Ethernet Board

Creating Cross-Connection Between the Ethernet and the Line Boards

Creating EPL Services

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 21

Configuring Ethernet Service--EPL


Configuring Port Attributes and Binding Paths of an Ethernet Board

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 22

Configuring Ethernet Service--EPL


Creating Cross-Connection
Between the Ethernet and the
Line Boards
1. In the NE Explorer, click the NE
and select [Configuration/SDH
Service Configuration] from the
Function Tree
2. Click <Create> and the "Create
SDH Service" dialog box is
displayed
3. Create the cross-connection
between the Ethernet board and
line board.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 23

Configuring Ethernet Service--EPL


Creating EPL Services
1. In the NE Explorer, click the NE and
select [Configuration/ Ethernet
Service/ Ethernet Leased Line
Service] from the Function Tree.
2. Click <New> ,and Enter the
information of the EPL service.
Select "Service Direction", "Source
Port", "Source Port VLAN ID", "Sink
Port", "Sink Port VLAN ID"

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 24

Configuring Ethernet Service

Configuring EVPL service

Procedure

Action

Configuring Port Attributes and Binding Paths of an Ethernet Board

Creating Cross-Connection Between the Ethernet and the Line Boards

Creating EVPL Services

..
HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 25

Configuring Ethernet Service --EVPL


Configuring Port Attributes and Binding Paths of an Ethernet Board

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 26

Configuring Ethernet Service--EVPL


Creating Cross-Connection
Between the Ethernet and the Line
Boards
1. In the NE Explorer, click the NE and
select [Configuration/SDH Service
Configuration] from the Function Tree
2. Click <Create> ,then Create the
cross-connection between the
Ethernet board and line board.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 27

Configuring Ethernet Service--EVPL


Creating EVPL Services
1. In the NE Explorer, click the NE and
select [Configuration/ Ethernet Service/
Ethernet Leased Line Service] from the
Function Tree.
2. Select Display Shared Service ,then
Click <New>
3. Enter the information of the EVPL
service. Select Service Direction, Source
Port, Source Port VLAN ID, Sink Port,
Sink Port VLAN ID

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 28

Configuring Ethernet Service

Configuring EPLn service

Procedure

Action

Configuring Port Attributes and Binding Paths of an Ethernet Board

Creating Cross-Connection Between the Ethernet and the Line Boards

Creating EVPL Services

Creating the VLAN Filtering Table

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 29

Configuring Ethernet Service--EPLn


Configuring Port Attributes and Binding Paths of an Ethernet Board

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 30

Configuring Ethernet Service--EPLn


Creating Cross-Connection
Between the Ethernet and the Line
Board
1. In the NE Explorer, click the NE and
select [Configuration/SDH Service
Configuration] from the Function Tree.
2. Click <Create> , Create the crossconnection between the Ethernet
board and line board.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 31

Configuring Ethernet Service--EPLn


Creating EPLn Services
1. In the NE Explorer, click the NE and select [Configuration/ Ethernet Service/ Ethernet
VLAN Service] from the Function Tree.
2. Click <New> , then Set the information of the EPLn service. Enter "VB Name"
3. Click <Configure Mount Port>. The "VB Mount Port Configuration" dialog box is
displayed. Select appropriate port in the "Available Mounted Ports" and click .

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 32

Configuring Ethernet Service--EPLn


Creating the VLAN Filtering Table
1. In the NE Explorer, click the NE and
select an appropriate board. Select
[Configuration/Layer-2 Switching
Management/Forwarding Filter Table]
from the Function Tree
2. Click <New>, then Enter the
information of this VLAN. Select the
"VB", specify the "VLAN ID", and select
the appropriate ports as forwarding
ports
HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 33

Configuring Ethernet Service

Configuring EVPLn service

Procedure

Action

Configuring Port Attributes and Binding Paths of an Ethernet Board

Creating Cross-Connection Between the Ethernet and the Line Boards

Creating EVPLn Service

Creating the VLAN Filtering Table

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 34

Configuring Ethernet Service--EVPLn


Configuring Port Attributes and Binding Paths of an Ethernet Board

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 35

Configuring Ethernet Service--EVPLn


Creating Cross-Connection Between
the Ethernet and the Line Boards
1. In the NE Explorer, click the NE and
select [Configuration/SDH Service
Configuration] from the Function Tree
2. Click <Create> ,then Create the crossconnection between the Ethernet board
and line board.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 36

Configuring Ethernet Service--EVPLn


Creating EVPLn Services
1. In the NE Explorer, click the NE and select [Configuration/ Ethernet Service/ Ethernet
VLAN Service] from the Function Tree.
2. Select Displayed Shared Service. . Click <New>
3. Set the information of the EPLn service. Enter "VB ID", "VB Name"
4. Click <Configure Mount Port>. The "VB Mount Port Configuration" dialog box is
displayed. Select appropriate port in the "Available Mounted Ports" and click >>

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 37

Configuring Ethernet Service--EVPLn


Creating the VLAN Filtering Table
1. In the NE Explorer, click the NE
and select an appropriate board.
Select [Configuration/Layer-2
Switching
Management/Forwarding Filter
Table] from the Function Tree
2. Click <New>, then Enter the
information of this VLAN. Select
the "VB", specify the "VLAN ID",
and select the appropriate ports
as forwarding ports
HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 38

Configuring Ethernet Service

Configuring RPR EVPL service

Procedure

Action

Configuring RPR Topology Information

Configuring Port Attributes and Binding Paths of an Ethernet Board

Creating Cross-Connection Between the Ethernet and the Line Boards

Creating EVPL Service

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 39

Configuring Ethernet ServiceRPR EVPL


Configuring RPR Topology Information
1. In the NE Explorer, select a board and select [Configuration/RPR
Management/Topology Management] from the Function Tree. Select the "Local Node
Information" tab
2. Set local node information, including "Node No" and "Node Name"
3. Start RPR protocol. Set "RPR Enable" as "Enabled"
4. Set protection parameters, including "Protection mode", "Protection delay (s)",
"Protection restoration mode" and "Protection wait-to-restore (s)"

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 40

Configuring Ethernet ServiceRPR EVPL


Configuring Port Attributes and Binding Paths of an Ethernet Board

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 41

Configuring Ethernet ServiceRPR EVPL


Creating Cross-Connection
Between the Ethernet and the
Line Boards
1. In the NE Explorer, click the NE
and select [Configuration/SDH
Service Configuration] from the
Function Tree
2. Click <Create> ,then Create the
cross-connection between the
Ethernet board and line board.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 42

Configuring Ethernet ServiceRPR EVPL


Creating RPR EVPL Services
1. In the NE Explorer, select a board and
select [Configuration/Ethernet
Service/Ethernet Leased Line Service]
from the Function Tree.
2. Click <New>. Then Enter the information
of the EVPL service. Select "Service
Direction", "Source Port", "Source Port
VLAN ID", "Sink Port", "Sink Port VLAN
ID", "Tunnel", "VC" and "Sink Port"
3. Click <OK>.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 43

Configuring Ethernet Service

Configuring RPR EVPLn service

Procedure

Action

Configuring RPR Topology Information

Configuring Port Attributes and Binding Paths of an Ethernet Board

Creating Cross-Connection Between the Ethernet and the Line Boards

Creating EVPLn Service

Creating the VLAN Filtering Table

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 44

Configuring Ethernet ServiceRPR EVPLn


Configuring RPR Topology Information
1. In the NE Explorer, select a board and select [Configuration/RPR
Management/Topology Management] from the Function Tree. Select the
"Local Node Information" tab
2. Set local node information, including "Node No" and "Node Name"
3. Start RPR protocol. Set "RPR Enable" as "Enabled"
4. Set protection parameters, including "Protection mode", "Protection delay
(s)", "Protection restoration mode" and "Protection wait-to-restore (s)"

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 45

Configuring Ethernet ServiceRPR EVPLn


Configuring Port Attributes and Binding Paths of an Ethernet Board

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 46

Configuring Ethernet Service--EVPLn

Creating Cross-Connection
Between the Ethernet and the
Line Boards
1. In the NE Explorer, click the NE and
select [Configuration/SDH Service
Configuration] from the Function Tree
2. Click <Create> ,then Create the crossconnection between the Ethernet board
and line board.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 47

Configuring Ethernet ServiceRPR EVPLn


Creating RPR EVPLn Services
1. In the NE Explorer, select a board and select [Configuration/Ethernet Service/Ethernet
VLAN Service] from the Function Tree .
2. Click <New>. Then Set EVPLn service information. Input "VB Name"

3.Click <Configure Mount Port>. The "VB Mount Port Configuration" dialog box is displayed.
Click <>>>
4.Click <OK>

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 48

Configuring Ethernet Service--EVPLn


Creating the VLAN Filtering Table
1. In the NE Explorer, select a board
and select [Configuration/ Layer-2
Switching Management/Forwarding
Filter Table] from the Function Tree
2. Click <Create> , Input the VLAN ID
to be forwarded, and select the
appropriate ports as forwarding
ports.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 49

Chapter 1 Quick Start


Chapter 2 Configure Services
Chapter 3 Maintenance

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 50

Maintenance
Synchronizing NE Time

Managing SDH Overhead Bytes

Browsing Alarms

Equipment Data Collection

Browsing Performance

Automatic Disabling of NE
Functions
Cleaning Up the Hard Disk of
the T2000-LCT Computer

Browsing the Operation Log

Checking Switching Status

HUAWEI TECHNOLOGIES CO., LTD.

Troubleshooting

All rights reserved

Page 51

Synchronizing NE Time
Manual Synchronization
1, Select [Configuration/NE Time Synchronization] from the Main Menu;
2, Select one or more NEs in the left pane and click the double-right-arrow button;
3, Modify the value of Synchronize Mode to NM.

Automatic Synchronization
1, Select [Configuration/NE Time Synchronization] from the Main Menu;
2, Select one or more NEs in the left pane and click the double-right-arrow button;
3, Set the Synchronize Starting Time and the Synchronization Period;
4, Click <Apply>.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 52

Browsing Alarms
Browsing Alarms:
Browsing Alarms includes:
1, Synchronizing Current Alarms.
2, Browsing Current Alarms.
3, Browse History Alarms.
4, Browsing Abnormal Events.
5, Browsing Alarm Statistics and Output Report.

HUAWEI TECHNOLOGIES CO., LTD.

1, Open NE slot diagram;


2, Select < Function> from NE panel and then
click <Browse Current Alarm>.

All rights reserved

Page 53

Browsing Alarms

1, Open NE slot diagram;


2, Right click the card form NE panel and
then select <Browse Current Alarm>.

Right click the NE panel from <NE


Information Management> view and then
select <Browse Alarms>.

Select [Fault/Browse
Current Alarm] from
the Main Menu

Click shortcut button


<Browse Current Alarm>

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 54

Browsing Alarm/Performance
Browsing the SDH/OSN Series
Performance includes:

Browsing Alarms
Click one of the three alarm shortcut buttons:
critical alarm, major alarm or minor alarm.

Browsing Current Performance Data;


Browsing History Performance Data;
Browsing UAT;
Browsing PM Threshold-crossing Record.

All the current alarms for the selected


severity are displayed.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 55

Routine Maintenance
Browsing the Operation Log
1, Select [System Administration/Operation
Log] from the Main Menu.
2, Select the browse conditions: Operation
Use, Record Type, Danger Severity, and
Range Selection.
3, Select the object choice at the upper right
area.

HUAWEI TECHNOLOGIES CO., LTD.

Checking Switching Status tasks


include:
1,Checking 1+1 Protection Switching Status;
2,Checking TPS Protection Switching Status;

All rights reserved

Page 56

Routine Maintenance
Equipment Data Collection
1, Select [System Administration/Equipment
Data Collection] from the Main Menu.
2, Select NEs and functions to be collected.
The equipment data include:
? Configuration data; ?

?
?
?
?
?

Equipment protection; ?
Equipment maintenance; ?
Alarm; ?
Performance;
Security.

HUAWEI TECHNOLOGIES CO., LTD.

Automatic Disabling of NE
Functions
1, Select [Configuration/Automatic
Disabling of NE Function] from the Main
Menu.
2, Select the appropriate NE and click the
double-right-arrow button (red). If
loopback or laser shutdown is enabled,
these functions will be displayed.
3, Keep the default status of auto disabling
unchanged and modify the value of "Auto
Disabling Time".
4, Click <Apply>.

All rights reserved

Page 57

Troubleshooting
Loopback SDH/PDH/Ethernet interface and VC4/VC3 path
1.In the NE Explorer, select a board and select [Configuration/SDH Interface] from the Function
Tree. Click the double-right-arrow button (red) .
2, Select By function. Select Optical/Electrical Interface Loopback
3, Select the loopback mode and click <Apply>, then Click <OK>. The Operation Result dialog
box is displayed and indicates operation succeeded. Click <Close>

1, If you want to make a loopback for PDH/Ethernet or other interface, you can select
[Configuration/PDH Interface] or Interface Management/Ethernet Interface Loopback]
2, If you want to make a loopback for VC4/VC3 path, in the above figure, you can select
Select By function. Select VC4/VC3 loopback
HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 58

Troubleshooting
Warm Resetting and Cold
Resetting Unit
1,Open slot diagram;
2, Right-click the unit. Select
[Warm Reset] or [Clod Reset].
3, Click <OK> in the confirm
dialog box.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 59

Summary

What are the configuration stages of


SDH/OSN equipment?

What are the routine maintenance items


for T2000-LCT?

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 60

Thank You
www.huawei.com