Académique Documents
Professionnel Documents
Culture Documents
TheSC4020QualificationUnitsDeploymentGuidedescribeshowtoinstallandconfigureSC4020
qualificationunits.
Contents
PreparingforInstallation .................................................................... 1
InstallingtheHardware ..................................................................... 2
BackEndConnections ....................................................................... 6
FrontEndConnections ...................................................................... 6
SetUpSoftwareCenterSoftware ............................................................. 12
PerformPostSetupTasks ................................................................... 46
Troubleshooting ........................................................................... 51
StorageSystemEnclosurewithtwoinstalledStorageControllerModules
TwoBatteryBackupUnits(BBU)
DellEnterprisePlusDrivesandDriveBlanks
Railkit
TwoPowerCables
Twoserialcables
TwoSAScables
FibreChannelcables
Ethernetcables
RackSpace:Theremustbesufficientspaceintheracktoaccommodatethestoragecontroller.
Power:Powermustbeavailableintherack,andthepowerdeliverysystemmustmeetthepower
requirementsforthestoragecontroller.
Connectivity:Therackmustbewiredforconnectivitytothemanagementnetworkandanynetworksthat
carryfrontendIOfromthestoragecontrollertoservers.
Dell
Makesurethatyouhavethefollowingitemsbeforeyoubegintheinstallation.
Required Item
Description
StorageCenterlicensefile
ControlswhichStorageCenterfeaturesareenabled.
HardwareSerialNumber(HSN)
andSystemSerialNumber(SSN)
Serialnumbersusedtoconfigurethestoragecontrollermodules.
LaptopwithRS232serialportor
USBport
Usedtoruncommandsandviewconsolemessagesduringstoragecontroller
moduleconfiguration.
Computerconnectedtothesame
managementnetworkasthe
storagecontrollermodule
UsedtoconnecttotheStorageCenterSystemManager(throughawebbrowser)
tocompletethestoragecontrollermoduleconfiguration.
Dell
Closethelatchoneachchassisear.
2 Slidethedriveintothebayuntilthecarriercontactsthebackplane.
3 Closetheharddrivecarrierhandletolocktheharddriveinplace.
4 Continuetopushfirmlyuntilyouhearaclickandthehandlefullyengages.
Dell
5 Whentheenclosureisturnedonandthedrivesspinup,makesurethatthedriveLEDsareon(green),
indicatingnormalconditions.
Name
Description
Harddriveactivityindicator Flashinggreen:Indicatesdriveactivity
Steadygreen:Indicatesnodriveactivity
Harddrivestatusindicator
Steadygreen:Normaloperation
Flashinggreen(on1sec/off1sec):DriveindicatorissettoOninSystem
Manager.
Off:Nopowertothedrive
Dell
ThebatterybackupunitshouldonlybereplacedwithaBBUthatisthesameorequivalentasthe
factoryinstalledBBU.
DonotattempttoopenorservicetheBBU.DonotdisposeoftheBBUinafireorwithhousehold
waste.Contactthelocalwastedisposalagencyforthelocationofthenearestbatterydepositsite.
1 AlignaBBUwithstoragecontrollermodule1.
2 Release tab
2 LiftthereleasetabandslidetheBBUintothestoragecontrollermoduleuntilitlocksinplace.
3 AlignaBBUwithstoragecontrollermodule2.
4 LiftthereleasetabandslidetheBBUintothestoragecontrollermoduleuntilitlocksinplace.
5 Whentheenclosureisturnedon,makesurethatthebatterybackupunitLEDsareon(green),indicating
normalconditions.
Name
Description
Armedindicator
Steadygreen:Armed
Flashinggreen(1beaton/3beatsoff):Notarmedandcharging
Flashinggreen(2beatson/2beatsoff):Notarmedandnotcharging
Faultindicator
Steadyamber:Batteryfault
Off:Nofault
Dell
Back-End Connections
CreateanIPCdirectconnectionbeconnectionSAScablebetweenthestoragecontrollermodules.
AddSAScablingbetweentheinitiatorandtargetportsofeachstoragecontrollermodule.
1 ConnectaSAScablebetweenstoragecontrollermodule1,portAandstoragecontrollermodule2,
portB.
2 ConnectaSAScablebetweenstoragecontrollermodule1,portAandstoragecontrollermodule2,
portB.
3 LabelbothendsofeachSAScablewithIPClabels.
Front-End Connections
FrontendconnectionsrefertotheFibreChannelconnectionsbetweentheSC4020andtheserver.Dell
CompellentrecommendsconnectingserverstotheSC4020usingthemostredundantoptionsavailable.
Pathredundancy:WhenmultiplepathsareavailablefromaservertoanSC4020,aserverconfiguredfor
multipathIO(MPIO)canusemultiplepathsforIO.Ifapathfails,theservercontinuestousethe
remainingactivepaths.
Storagecontrollermoduleredundancy:IfonestoragecontrollermodulefailsinanSC4020,thefront
endportsfailovertothefunctioningstoragecontrollermodule.Bothfrontendconnectivitymodes
(legacymodeandvirtualportmode)providestoragecontrollermoduleredundancy.
Dell
Portredundancy:Invirtualportmode,ifaportgoesdownbecauseitisdisconnectedorthereisa
hardwarefailure,theportcanfailovertoanotherfunctioningportinthesamefaultdomain.Port
redundancyisavailableonlyforStorageCentersoperatinginvirtualportmode.
Guidelines
Legacymode
IncludeallStorageCenterfrontendWWNsorportsinasinglezone.
Createserverzonesthatcontainasingleinitiatorandmultipletargets,and
whichincludetheserverHBAWWN.
Virtualportmode
IncludeallStorageCentervirtualWWNsinasinglezone.
IncludeallStorageCenterphysicalWWNsinasinglezone.
Createserverzonesthatcontainasingleinitiatorandmultipletargets(Storage
CentervirtualWWNs),andwhichincludetheserverHBAWWN.
FibreChannelreplication
IncludeallStorageCenterphysicalWWNsfromstoragecontrollermodule1
andstoragecontrollermodule2inasinglezone.
IncludeallStorageCenterphysicalWWNsofstoragecontrollermodule1and
thevirtualWWNsofstoragecontrollermodule2ontheparticularFabric.
IncludeallStorageCenterphysicalWWNsofstoragecontrollermodule2and
thevirtualWWNsofstoragecontrollermodule1ontheparticularFabric.
Note: Someportsmaynotbeusedordedicatedforreplication,howeverports
thatareusedmustbeinthesezones.
Guidelines
Legacymodeorvirtualportmode IncludeallStorageCenterfrontendports.
CreateserverzoneswhichcontainallStorageCenterfrontendportsanda
singleserverport.
FibreChannelreplication
Dell
IncludeallStorageCenterfrontendportsfromSystemAandSystemBina
singlezone.
Inthisconfiguration,twofaultdomainsarespreadacrossbothstoragecontrollermodules.Eachfault
domaincontainssetsofprimaryandreservepaths(P1R1andP2R2).Thereservedpathsprovide
redundancyforasinglestoragecontrollermodulefailure.Thisconfigurationisvulnerabletoswitchfailure.
Prerequisites
EachstoragecontrollermodulemusthavetwoavailableFCfrontendports.
Steps
1 ConnecteachFCservertotheFCfabric.
2 Connectfaultdomain1(showninorange)tofabric1.
PrimaryPortP1:StorageControllerModule1,Port1Fabric1
ReservedPortR1:StorageControllerModule2,Port1Fabric1
3 Connectfaultdomain2(showninblue)tofabric1.
PrimaryPortP2:StorageControllerModule2,Port2Fabric1
ReservedPortR2:StorageControllerModule1,Port2Fabric1
4 ConfigureFCzoningtomeetthelegacymodezoningrequirements.
2 Server 2
Dell
UsetwofabricswithlegacymodetopreventanFCswitchfailureorstoragecontrollermodulefailurefrom
causinganoutage.
Inthisconfiguration,fourfaultdomainsarespreadacrossbothstoragecontrollermodules.Eachfault
domaincontainssetsofprimaryandreservepaths(P1R1,P2R2,P3R3,andP4R4).Toprovide
redundancy,theprimaryportandthecorrespondingreserveportinafaultdomainmustconnecttothe
samefabric.WhenMPIOisconfiguredontheFCservers,theprimarypathsprovideredundancyfora
singleportorcablefailure.Thereservedpathsprovideredundancyforstoragecontrollermodulefailures.
Prerequisites
EachstoragecontrollermodulemusthavetwoavailableFCfrontendportsforeachFCfabric.
Steps
1 ConnecteachFCservertobothFCfabrics.
2 Connectfaultdomain1(showninorange)tofabric1.
PrimaryPortP1:StorageControllerModule1,Port1Fabric1
ReservedPortR1:StorageControllerModule2,Port1Fabric1
3 Connectfaultdomain2(showninblue)tofabric1.
PrimaryPortP2:StorageControllerModule2,Port1Fabric1
ReservedPortR2:StorageControllerModule1,Port1Fabric1
4 Connectfaultdomain3(showningreen)tofabric2.
PrimaryPortP3:StorageControllerModule1,Port3Fabric2
ReservedPortR3:StorageControllerModule2,Port3Fabric2
5 Connectfaultdomain4(showninpurple)tofabric2.
PrimaryPortP4:StorageControllerModule2,Port4Fabric2
ReservedPortR4:StorageControllerModule1,Port4Fabric2
6 ConfigureFCzoningtomeetthelegacymodezoningrequirements.
2 Server 2
Dell
ConnectvirtualportmodeFibreChanneltoasinglefabricifonlyoneFCisavailableandyouwantto
protectagainstportorstoragecontrollermodulefailure.
Inthisconfiguration,thereisonefaultdomainbecausethereisasingleFCfabric.Eachstoragecontroller
moduleisconnectedtothefabricbyatleasttwoFCconnectionstoprovideportredundancy.Ifasingleport
fails,itsvirtualportfailsovertoanotherport.Ifastoragecontrollermodulefails,thevirtualportsonthe
failedstoragecontrollermodulemovetoportsontheotherstoragecontrollermodule.Thisconfiguration
isvulnerabletoswitchfailure.
Prerequisites
EachstoragecontrollermodulemusthavetwoavailableFCfrontendports.
Therequirementsforvirtualportmodemustbemet.
Steps
1 ConnecteachservertotheFCfabric.
2 Connectfaultdomain1(showninorange)tofabric1.
StorageControllerModule1,Port1Fabric1
StorageControllerModule1,Port2Fabric1
StorageControllerModule2,Port1Fabric1
StorageControllerModule2,Port2Fabric1
3 ConfigureFCzoningtomeetthelegacymodezoningrequirements.
2 Server 2
Dell
10
UsetwofabricswithvirtualportmodetopreventanFCswitchfailureorstoragecontrollermodulefailure
fromcausinganoutage.
Inthisconfiguration,thereisonefaultdomainforeachFCfabric.Eachstoragecontrollermoduleis
connectedtobothfabricsbytwoFCconnections.Ifasingleportfails,itsvirtualportfailsovertoanother
portinthesamefaultdomain.Ifastoragecontrollermodulefails,thevirtualportsonthefailedstorage
controllermodulemovetoportsontheotherstoragecontrollermoduleinthesamefaultdomain.
Prerequisites
EachstoragecontrollermodulemusthavetwoavailableFCfrontendportsforeachFCfabric.
Therequirementsforvirtualportmodemustbemet.
Steps
1 ConnecteachservertobothFCfabrics.
2 Connectfaultdomain1(showninorange)tofabric1.
StorageControllerModule1,Port1Fabric1
StorageControllerModule1,Port2Fabric1
StorageControllerModule2,Port1Fabric1
StorageControllerModule2,Port2Fabric1
3 Connectfaultdomain2(showninblue)tofabric2.
StorageControllerModule1,Port3Fabric2
StorageControllerModule1,Port4Fabric2
StorageControllerModule2,Port3Fabric2
StorageControllerModule2,Port4Fabric2
4 ConfigureFCzoningtomeetthelegacymodezoningrequirements.
2 Server 2
Dell
11
Prerequisites
LocatetheEthernetmanagementcablesandmanagementlabelsthatshippedwiththeSC4020.
1 ConnectthemanagementportoneachstoragecontrollermoduletoanEthernetswitchorVLAN.
2 Ethernet cable
3 Ethernet cable
2 LabelbothendsofeachEthernetmanagementcablewithmanagementlabels.
Dell
12
Caution: WhentheSC4020ispoweredon,thereisaoneminutedelaywhiletheSC4020
preparestoboot.Duringthistime,theonlyindicationthattheSC4020ispoweredonarethe
LEDsonthestoragecontrollermodules.Aftertheoneminutedelay,theSC4020fansandLEDs
turnonasanindicationthatthestoragecontrollermodulesarestartingtocomeup.
1 EnsurethatthepowerswitchesareintheOFFpositionbeforeconnectingthepowercables.
Dell
13
Prerequisites
eth0supportssystemloginandaccessforthesoftware.Itisusedtosendemails,alerts,SNMPtraps,and
PhoneHomedata.
eth1isusedfordedicatedInterprocessCommunication(IPC)betweenstoragecontrollermodules.
Becauseeth1isdirectlyconnectsbothstoragecontrollermodules,nodefaultgatewayisrequired.
Caution: Donotchangetheeth1addressunlessbothstoragecontrollermoduleswerefactory
configuredwiththesameaddressorthecustomerrequeststhechange.Theeth1addresscannot
resideinthesamesubnetaseth0.
Steps
1 Usethesuppliedserialcable(RS232to3.5mmminiconnector)toconnectfromaPCorlaptoptoa
storagecontrollermodule.(ToconnectfromaUSBportonaPCorlaptop,useaUSBtoRS232
converter.)
2 OpenaterminalemulatororacommandlineinterfaceonthePCorlaptop.
3 Configuretheconnectionasshowninthefollowingtable.
Dell
Setting
Value
Emulation
VT220
ColumnMode
132
LineWrapping
Off
Connection
SerialPort
ConnectionType
Direct
BaudRate
115,200
14
Setting
Value
Parity
None
DataBits
StopBits
FlowControl
Hardwareordefault
Note: Tofacilitatetroubleshooting,enableloggingforthesession.
4 PresstheEnterkeyseveraltimestoinitiatetheconnection.Theterminaldisplaystheprompt
<SafeMode> sn0>toindicatethatthestoragecontrollermoduleisinSafeMode.
5 Runthefollowingcommandtoentertheshellacessdevelopermode.
shellaccess developer
6 Performthefollowingstepstospecifytherequiredprejoinconfigurationinformationonstorage
controllermodule1(leaderstoragecontrollermodule):
a Runthefollowingcommandtodisplaytheprejoinconfigurationinformationthatmustbespecified.
platform prejoin show
Example:
<SafeMode> sn0> platform prejoin show
****************************************************************
Prejoin configuration:
Item
Local controller
Remote controller
-----------Canister
SSN
HSN
eth0 IPv4
eth0 IPv6
eth1 IPv4
eth1 IPv6
gateway IPv4
gateway IPv6
Domain
DNS Server 0
DNS Server 1
-------------------------------0
0
0
10.0.10.225/8
::/128
169.254.0.100/16
::/128
0.0.0.0
::
-------------------------------1
0
0
0.0.0.0/32
::/128
169.254.0.101/16
::/128
0.0.0.0
::
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
****************************************************************
SSN not configured.
Local HSN not configured.
When all issues identified above are corrected, type:
'-sm -go'
to continue normal processing.
****************************************************************
b RunthefollowingcommandstosettheHSNandSSNusingtheSSNprovidedinthepreinstallation
documents.
Dell
15
Example:
platform init hsn set 10001
platform init ssn set 10001
RunthefollowingcommandtospecifyanIPaddressandsubnetmaskforthemanagementinterface
(eth0).
ifconfig inet eth0 [IPaddress]/[prefixlength]
Example:
ifconfig inet eth0 198.51.100.99/24
d Runthefollowingcommandtospecifythegatewayaddress.
ifconfig inet gateway [gatewayaddress]
Example:
ifconfig inet gateway 198.51.100.1
e Runthefollowingcommandtospecifythedomainname.
ifconfig domainname [domain name]
Example:
ifconfig domainname corp.dom
RunthefollowingcommandtospecifyoneormoreDNSservers.
net dns init [DNS server 1] [DNS server 2]
Example:
net dns init 203.50.113.55 203.50.113.90
g Runthefollowingcommandtoverifythattheprejoinconfigurationinformationiscomplete.
platform prejoin show
h Runthefollowingcommandtosavechangestotheconfiguration.
ifconfig save
Runthefollowingcommandtoexitsafemodeandrebootthestoragecontrollermodule.
-sm -go
Note: Thestoragecontrollermoduletakesseveralminutestorebootanditmayrebootmore
thanoncethisisnormal.
7 Performthefollowingstepstospecifytherequiredprejoinconfigurationinformationonstorage
controllermodule2(peerstoragecontrollermodule):
a Runthefollowingcommandtodisplaytheprejoinconfigurationinformation.
platform prejoin show
Example:
<SafeMode> sn0> platform prejoin show
****************************************************************
Prejoin configuration:
Dell
Item
Local controller
-----------Canister
SSN
-------------------------------1
0
Remote controller
-------------------------------0
0
16
HSN
eth0 IPv4
eth0 IPv6
eth1 IPv4
eth1 IPv6
gateway IPv4
gateway IPv6
Domain
DNS Server 0
DNS Server 1
0
10.0.10.173/8
::/128
169.254.0.101/16
::/128
0.0.0.0
::
0
0.0.0.0/32
::/128
169.254.0.100/16
::/128
0.0.0.0
::
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
****************************************************************
SSN not configured.
Local HSN not configured.
When all issues identified above are corrected, type:
'-sm -go'
to continue normal processing.
b RunthefollowingcommandstosettheHSNandSSNusingtheSSNprovidedinthepreinstallation
documents.
platform init hsn set [higher SSN]
platform init ssn set [higher SSN]
Example:
platform init hsn set 10002
platform init ssn set 10002
RunthefollowingcommandtospecifyanIPaddressandsubnetmaskforthemanagementinterface
(eth0).
ifconfig inet eth0 [IPaddress]/[prefixlength]
Example:
ifconfig inet eth0 198.51.100.100/24
d Runthefollowingcommandtospecifythegatewayaddress.
ifconfig inet gateway [gatewayaddress]
Example:
ifconfig inet gateway 198.51.100.1
e Runthefollowingcommandtoverifythattheprejoinconfigurationinformationiscomplete.
platform prejoin show
Runthefollowingcommandtosavechangestotheconfiguration.
ifconfig save
g Runthefollowingcommandtoexitsafemodeandrebootthestoragecontrollermodule.
-sm -go
Note: Thecontrollermoduletakesseveralminutestorebootanditmayrebootmorethan
oncethisisnormal.
Dell
17
Prerequisites
YoumusthaveacomputerthathasconnectivitytotheStorageCentermanagementinterface.Thecomputer
musthavethefollowingsoftwareinstalled:
Oneofthefollowingsupportedwebbrowsers(otherbrowsersandversionsmayhavelimited
compatibility):
MicrosoftWindowsInternetExplorerVersions7,8,and9
MicrosoftWindowsInternetExplorer10and11onthedesktop(InternetExplorer10and11Modern
versionisnotsupported)
MozillaFirefoxonMicrosoftWindows
The32bit(x86)JavaRuntimeEnvironmentmustbeinstalledtorunStorageCenterSystemManagerin
any32bitbrowser.
Steps
1 Useasupportedwebbrowsertoconnecttotheeth0IPaddressorhostnameofstoragecontroller
module1.
2 Acknowledgeanysecuritymessages.
Note: Securitymessagesthatappearmaydifferdependingonthebrowserused.(ClickContinue
tothiswebsiteinInternetExploreroraddasecurityexceptioninFirefox.)
TheStorageCenterLoginpageappears.
3 Enterthedefaultusernameandpassword:
User:Admin
Password:mmm
Note: Theusernameandpasswordarecasesensitive.
4 ClickLogin.
Dell
18
5 Ifthepasswordexpiredpageappears,enteranewpasswordfortheAdminuser:
a EntertheoldpasswordintheOldPasswordfield
b EnteranewpasswordintheNewPasswordandConfirmPasswordfields.
c
ClickLogin.ThepasswordischangedandyouareloggedintotheStorageCenterSystemManager.
6 Ifprompted,clickYestoacknowledgecertificatemessages.
TheStartupWizardappearsanddisplaystheSoftwareEndUserLicenseAgreement(EULA).
snxxxistheserialnumberoftheStorageCenter.
35indicatesthatthesystemrunssoftwarehigherthanversion3.5.
dateshowsthelicensegenerationdateinYYMMDDformat.
.licisthefileextension.
Dell
19
3 Selectthelicensefile,thenclickLoadLicense.TheStartupWizarddisplaysamessagewhenthelicense
issuccessfullyloaded.
Ifthelicenseloadssuccessfully,themessageThelicensesubmissionhascompletedsuccessfully
appears.
IfthemessageError:Thelicensefileisnotvalidmessageisdisplayed,seeTroubleshootingLicenses
onpage 52.
4 ClickContinue.TheCreateDiskFolderpageappears.
Dell
20
Note: IftheNodiskscouldbefoundmessageisdisplayed,seeTroubleshootingStorageSystem
Enclosuresonpage 51.
1 Selectdisksforthediskfolder.Bydefault,theStartupWizardselectsallavailabledisks.
a ScrollthroughthelistlookingatthePositionorNamecolumntoverifythatalltheexpecteddisks
arelisted.
Ifdisksaremissing,theissuesmightbefixedbyfollowingTroubleshootingStorageSystem
Enclosuresonpage 51.
b (Optional)Fromthelistofdisks,selectdiskstoincludeinthediskfolder.Bydefault,alldisksare
selected.
Toexcludeindividualdisksfromthediskfolder,clearthecorrespondingcheckboxes.
Toincludeindividualdisksinthediskfolder,clickUnselectAllandthenselecttheindividual
disksinclude.
Toselectalldisks,clickSelectAll.
Note: DellCompellentrecommendsselectingallavailablediskstomaximizethebenefitsof
DataProgression.
Dell
ClickContinue.TheStartupWizarddisplaysaprompttoselectdiskstodesignateashotspares.
21
2 ReviewthehotsparedisksselectedbytheStartupWizard.
Ahotsparediskisheldinreserveuntiladiskfails,atwhichpointthehotsparereplacesthefaileddisk.
Thehotsparediskmustbeaslargeorlargerthanthelargestdiskofitstypeinthediskfolder.
a (Optional)Changetheselectionbyselectingorclearingdiskstobeusedashotspares.
b ClickContinue,andifprompted,clickOKtoconfirm.TheStartupWizarddisplaysasummaryof
thediskfolderthatwillbecreated.
3 (Optional)ModifythedefaultfoldernameandenteradescriptionintheNotesfield.
4 (Optional)ClickAdvancedtoconfigureadvanceddiskfolderoptions.Thewizarddisplaysoptionsfor
redundancyanddatapagesize.
Dell
22
Note: Thedefaultmanageddiskfoldersettingsareappropriateformostsites.Ifyouare
consideringchangingthedefaultsettings,contactDellTechnicalSupportServicesforadvice.
a SelectPrepareDiskFolderforredundantstorage.
b ConfiguretheTierRedundancyforeachtier.
Theredundancylevelforeachtierdefaultstoeithersingleredundantordualredundantdepending
uponthedisksexpectedtobefoundinthetier.Ifatiercontainsatleastsixmanageddisksofwhich
oneis900GBorgreater,thenthattierandalltiersbelowitaresettodualredundantstorageby
default.Ifatiercontainsatleastsixmanageddisksof1.8TBorgreater,thenthattierandalltiers
belowitaresettodualredundantstorageandcannotbechanged.
Singleredundantstorageprotectsagainstthelossofanyonedrive.
RAID10(eachdiskismirrored)
RAID55(4datasegments/1paritysegmentperstripe)
RAID59(8datasegments/1paritysegmentperstripe)
Dualredundantstorageprotectsagainstthelossofanytwodrives:
Dell
RAID10DualMirror(dataiswrittensimultaneouslytothreeseparatedisks)
RAID66(4datasegments/2paritysegmentsperstripe)
RAID610(8datasegments/2paritysegmentsperstripe)
FromtheDatapageSizedropdownmenu,chooseadatapagesize.
2MB:(Default)Recommendedformostapplicationneeds.
512KB:Appropriateforapplicationswithhighperformanceneeds(suchascertaindatabases)or
environmentsinwhichReplaysaretakenfrequentlyunderheavyIO.Selectingthissizereduces
theamountofspacetheSystemManagercanpresenttoservers.
4MB:AppropriateforsystemsthatusealargeamountofdiskspacewithinfrequentReplays
(suchasvideostreaming).
23
Caution: Whenconsideringusingeitherthe512KBor4MBdatapagesettings,itis
recommendedthatyoucontactDellTechnicalSupportServicesforadviceonbalancing
resourcesandtounderstandtheimpactonperformance.
d ToconfigurethediskfoldertouseRAID0,selectthePrepareforNonRedundantStoragecheckbox.
Nonredundantstoragedoesnotprotectdataintheeventofadiskfailure.Selectthisoptiononlyfor
datathatisbackedupsomeotherway.
e ClickContinue.
5 ClickCreateNow,andifprompted,clickOKtoconfirm.TheAddControllerpageappears.
Dell
24
Ifthestoragecontrollermodulesfailtojoinautomatically,usetheManuallyAddControllerpagetojointhe
storagecontrollermodules.
1 IftheIPv6addresssettingsofthestoragecontrollermodulearenotconfigured,theConfigurethe
LeaderControllersIPv6addressvaluespageappears.
IfthemanagementnetworkusesIPv6:
a EntertheIPv6IPaddressintheIPv6Addressfield.
b EntertheIPv6prefixlengthinIPv6PrefixLengthfield.
c
EntertheIPv6gatewayaddressvaluesintheIPv6Gatewayfield.
d ClickContinue.
IfthemanagementnetworkdoesnotuseIPv6,clickSkipIPv6Configuration.
2 ClickAddController.Thewizardpromptsyouforinformationaboutthesecondstoragecontroller
module.
Note: Informationdisplayedinthefollowingfigureisforillustrationonly.Thevaluesdisplayed
areuniquetoeachStorageCenter.
3 Configurethefollowingfields:
ControllerID:TheHSNforstoragecontrollermodule2isincludedinthelicensefileandtheadd
controllerprocessusesthatvalueastheControllerIDandadifferentvaluecannotbeentered.Ifthe
HSNforstoragecontrollermodule2isnotinthelicensefile,entertheHSNvalue.Thedimmedbox
intheprecedingfigureindicatesthattheHSNwasinthelicensefilemakingtheControllerIDbox
unavailable.
Ether0Interface:EntertheIPv4Address,IPv4NetMask,IPv4Gateway,IPv6Address,IPv6Prefix
Length,IPv6GatewayfortheEther0interfaceoncontroller module2.
Ether1Interface:EntertheIPAddress,NetMask,andGatewayfortheEther1interface.UsetheIP
addressfromthecontroller showconsolecommandforstoragecontrollermodule2.(Usedfor
communicationbetweenstoragecontrollermodules.)
PrimaryDNSServer:EntertheIPaddressoftheprimaryDNSserver.
Dell
25
SecondaryDNSServer:(Optional)EntertheIPaddressofasecondaryDNSserver.
DomainName:(Optional)Enterthedomainnameforthestoragecontroller.
4 ClickContinue.
TheStartupWizarddisplaysamessagethatdataandconfigurationinformationonthesecondstorage
controllermodulewillbelostandasksforconfirmation.
5 ClickJoinNow.Waitfortheprocesstocompleteandforthestoragecontrollermoduletoreboot,which
cantakeafewminutes.Whencomplete,theTimeSettingspageappears.
Dell
26
UsetheTimeSettingspagetosetthesystemtimefortheSC4020.
1 Setthetimezone.
a FromtheRegiondropdownmenu,selectthegeographicalregioninwhichtheSC4020islocated.
b FromtheTimeZonedropdownmenu,selectthetimezoneinwhichtheSC4020islocated.
Note: ForlocationsintheUnitedStates,eitherselectUSastheregionandselectatimezone
name,orselectAmericaastheregionandselectacitywithinthesametimezone.
2 Setthesystemtimeusingoneofthefollowingmethods.
Toconfiguretimemanually,selectConfigureTimeManually,thenenterthedateandtime.
ToconfiguretimeusingaNetworkTimeProtocol(NTP)server,selectUseNTPTimeServer,then
enterthefullyqualifieddomainname(FQDN)orIPaddressofanNTPserver.
Note: Accuratetimesynchronizationiscriticalforreplications.DellCompellentrecommends
usingNTPtosetthesystemtime.Formoreinformation,see:support.ntp.org/bin/view/Support/
WebHome.
3 Whenthesystemtimehasbeenset,clickContinue.TheSystemSetuppageappears.
Dell
27
UsetheSystemSetuppagetosetthesystemnameandmanagementIPaddressfortheSC4020.
1 IntheSystemNamefield,enteranamefortheSC4020.Thisistypicallytheserialnumberofstorage
controllermodule1.
2 IntheManagementIPAddress(IPv4)field,enterthemanagementIPaddressspecifiedinthepre
installationdocuments.
ThemanagementIPaddressisdistinctfromstoragecontrollermodule1andstoragecontrollermodule
2addresses.ItistheaddressthatmanagesanSC4020asawhole.Ifeitherstoragecontrollermodulefails,
themanagementIPaddressremainsvalid.
Dell
28
3 IntheManagementIPAddress(IPv6)field,enterthemanagementIPaddressspecifiedinthepre
installationdocuments.
4 ClickContinue.Thewizardpromptsyoutoenableordisablethereadandwritecache.
5 Selectorclearthecheckboxestoenableordisablereadandwritecache.
Note: Disablecacheonlyifnovolumeswilleverusecache.Ifcacheisleftenabledonthispage,
itcanbedisabledlaterforindividualvolumes.SeetheStorageCenterSystemManager
AdministratorsGuideforinformationondisablingcacheonavolumebyvolumebasis.
6 ClickContinue.TheConfigureSMTPpageappears.
Dell
29
UsetheConfigureSMTPpagetoconfiguretheSMTPmailserverandthesenderemailaddress.This
configurationenablesalertmessageemailstobesenttouserswhohavespecifiedarecipientaddressintheir
contactproperties.
1 IntheSMTPMailServerfield,entertheIPaddressorfullyqualifieddomainnameoftheSMTPemail
server.ClickTestservertoverifyconnectivitytotheSMTPserver.
2 IntheSenderEmailAddressfield,entertheemailaddressofthesender.Thisaddressisrequiredby
mostSMTPserversandisusedastheMAILFROMaddressofemailmessages.
3 (Optional)ClickAdvancedtoconfigureadditionalSMTPsettingsforsitesthatuseanadvancedSMTP
configuration.Thepageforadvancedoptionsappears.
Dell
30
a VerifythattheEnableSMTPEmailcheckboxisselected.
b IntheSMTPMailServerfield,verifytheIPaddressorfullyqualifieddomainnameoftheSMTP
mailserverthatyouenteredinStep 1onpage 30.Modifythisfieldifnecessary.
c
IntheBackupSMTPMailServerfield,entertheIPaddressorfullyqualifieddomainnameofthe
backupSMTPmailserver.
d ClickTestservertotesttheconnection.
e IntheSenderEmailAddress(MAILFROM)field,verifytheemailaddressofthesenderthatyou
enteredinStep 2onpage 30.Modifythisfieldifnecessary.
f
IntheCommonSubjectLinefield,enteracommonsubjectlineforallemailsfromSC4020.
g (Optional)SelectSendExtendedHello(EHLO)toconfigureuseofextendedhelloformailsystem
compatibility.
InsteadofbeginningthesessionwiththeHELOcommand,thereceivinghostissuestheHELO
command.Ifthesendinghostacceptsthiscommand,thereceivinghostthensendsitalistofSMTP
extensionsitunderstands,andthesendinghostthenknowswhichSMTPextensionsitcanuseto
communicatewiththereceivinghost.ImplementingExtendedSMTP(ESMTP)requiresno
modificationoftheSMTPconfigurationforeithertheclientorthemailserver.
h (Optional)SelectUseAuthorizedLogin(AUTHLOGIN)andentertheLoginIDandPasswordif
theemailsystemrequirestheuseofanauthorizedlogin.
4 ClickContinue.TheUpdateSetuppageappears.
Dell
31
UsetheUpdateSetuppagetoconfigurehowSC4020handlessoftwareupdates.
1 Selectanupdateoptionfromthedropdownmenu:
Donotautomaticallycheckforsoftwareupdates:Selectthisoptiontodisableautomaticchecking
forupdates.Ifthisoptionisselected,thefollowingwillstillbeavailable:
ManuallycheckforupdatesbyselectingStorageManagementSystemUpdateCheckfor
UpdateasdescribedintheSC4020SystemManagerAdministratorsGuide.
ChangeupdateoptionsbyselectingStorageManagementSystemUpdateConfigure
AutomaticUpdatesasdescribedintheSC4020SystemManagerAdministratorsGuide.
Notifymeofasoftwareupdatebutdonotdownloadautomatically:Selectthisoptionto
automaticallycheckforupdatesandreceivenotificationwhenanupdateisavailable.Updatesare
notdownloadeduntilyouexplicitlydownloadtheupdate.(Thisisthedefaultsetting.)
Downloadsoftwareupdatesautomaticallyandnotifyme:Selectthisoptiontoautomatically
downloadupdatesandreceivenotificationwhenthedownloadiscomplete.
Nevercheckforsoftwareupdates(PhoneHomenotavailable):Selectthisoptiontopreventthe
systemfromevercheckingforupdates.ThisoptionisforsecuresitesatwhichPhoneHomeisnot
available.
2 ClickContinue.TheUserSetuppageappears.
Dell
32
UsetheUserSetuppagetothesessiontimeoutandemailaddressesfortheAdminaccount.
3 FromtheSessionTimeoutdropdownlist,selectthesessiontimeout.
4 IntheEmail,Email2,andEmail3fields,enteremailaddressestowhichtheStorageCenterwillsend
systemalerts.
5 (Optional)ClickSendtestemailtomakesurethattheemailaddressesareaccurate.
Note: Makesurethetestemailisreceivedbyanadministrator.StorageCenterusesemailtosend
systemalerts.
6 ClickContinue.
Dell
33
The10GbEthernetiSCSIportsoneachstoragecontrollermoduleareonlyusedforreplicationtoanother
StorageCenter.TheiSCSIportsshouldnotbeusedforfrontendconnectivitytoservers.
1 (Optional)ClickSkipiSCSIIOCardConfigurationtoconfigurenetworksettingsfortheiSCSIports
atalatertime.TheConfigurePortspageappears.
Note: DellCompellentrecommendsthatyouconfiguretheiSCSIportsduringsetup.
2 CompletetheIPAddress,aSubnetMask,andaGatewayfields.
3 ClickContinue.
Ifnomessagesaregenerated,theiSCSIportconfigurationissavedandtheConfigurePortspage
appears.
Ifthereisanissue,amessageappears.
Dell
ClickNotogobackandcorrecttheIPAddress,SubnetMask,and/orGatewayaddressforthe
iSCSIportsthatgeneratederrorsand/orwarnings.
ClickYestoignorethemessageandcontinue.TheConfigurePortspageappears.
34
Then
VirtualPortsisNotLicensed
AlltransporttypesuseLegacyMode.Inthiscase,theStartupWizard
displaystheInitialPortConfigurationpage.Tocontinue,gotoConfigure
PortsWhenVirtualPortModeIsNotLicensedonpage 35.
VirtualPortsisLicensed
TheFCtransporttypecanuselegacymodeorvirtualportmode.Inthiscase,
theStartupWizarddisplaysanoperationalmodechoicepagethatallowsfor
thechoicebetweenmodesforeachsupportedtransporttype.Tocontinue,go
toConfigurePortsWhenVirtualPortModeIsLicensedonpage 37.
Note: ToskipportinitializationorifthereisnoFCswitchsetup,clickSkipPortInitialization.
1 ClickContinuetogeneratetheinitialportconfiguration.
Whiletheinitialportconfigurationisbeinggenerated,theStartupWizarddisplaysapageshowing
progress.Aftertheconfigurationhasbeengenerated,itisautomaticallyvalidated.
Ifthevalidationissuccessful,aconfirmationpageappearsstatingthattheportconfigurationhas
beengenerated.
Ifthevalidationfails,apagedisplayingwarningsappears.
Dell
35
2 ClickConfigureLocalPorts.ThewizarddisplaysatabforeachtypeofIOcardthatisinstalledinthe
StorageCenter.
3 ConfigurethePurpose,FaultDomain,andUserAliasforalltransporttypes.SeeConfigureLocalPorts
onpage 40.
4 Whenyouarefinishedconfiguringthelocalports,clickAssignNow.Thewizardinformsyouthatthe
portconfigurationhasbeengenerated.
Dell
36
5 ClickContinue.TheGenerateSSLCertpageappears.
1 Selectthefrontendconnectivitymode.
a SelecttheoperationalmodefortheFCtransporttype.
b ClickContinuetoconfiguretheselectedoperationalmode.Thewizardinformsyouthatthe
operationalmodeshavebeenconfigured.
Dell
37
ClickContinuetobeginportinitializationintheselectedoperationalmode.
Thewizardverifiestheconfiguration,convertsselectedtransportstotheselectedmode,displays
progresspages,andpresentsaconfirmationpagewhenoperationalmodesfortransporttypeshave
beenconfiguredandinitialized.
Dell
38
d ClickConfigureLocalPorts.ThewizarddisplaysatabforeachtypeofIOcardthatisinstalledin
theStorageCenter.
2 ConfigurethePurpose,FaultDomain,andUserAliasforalltransporttypes.SeeConfigureLocalPorts
onpage 40.
3 Whenyouarefinishedconfiguringthelocalports,clickAssignNow.Thewizardinformsyouthatthe
portconfigurationhasbeengenerated.
4 ClickContinue.TheGenerateSSLCertpageappears.
Dell
39
ConfigurethePurpose,FaultDomain,andUserAliasforalltransporttypes.Validportpurposesfor
transporttypesdependonwhethervirtualportsmodeislicensedonSC4020.
ConfigureFCPortsLegacyModeonpage 41
ConfigureFCPortsVirtualPortModeonpage 42
ConfigureSASPortsonpage 43
Thefollowingtableshowstheportpurposesforeachtransporttype.
Port Purpose
Transport Type
Description
FCandSAS
Oneofthefollowing:
Legacy Mode
Unknown
Portpurposeisnotyetdefined.
Theportisunused.
(SASandFConly)Theportisusedfordirectconnect
interprocesscommunication(IPC).
FrontEndPrimary
FC
PortisconnectedtoserversandisusedfortheserverIOpath.
FrontEndReserved
FC
Portisconnectedtoserversandusedasafailoverpath.Only
usedfordualcontrollerStorageCenters.
BackEnd
FCandSAS
Portisconnectedtodiskenclosures.
DirectConnect
FC
Thisportpurposeisnotused.Donotselectitforanyports.
FCandSAS
Oneofthefollowing:
Portpurposeisnotyetdefined.
Theportisunused.
(SASandFConly)Theportisusedfordirectconnect
interprocesscommunication(IPC).
FrontEnd
FC
PortisconnectedtoserversandisusedfortheserverIOpath.
BackEnd
FC
Portisconnectedtodiskenclosures.
Dell
40
1 ClicktheFCtab.
2 CreateafaultdomainforeachpairofredundantFCports.
a ClickEditFaultDomains.Thewizarddisplaysalistofthecurrentlydefinedfaultdomains.
b ClickCreateFaultDomain.Adialogboxappears.
c
IntheNamefield,typeanameforthefaultdomain.
d FromtheTypedropdownmenu,selectFC.
e (Optional)IntheNotesfield,typeadescriptionofthefaultdomain.
f
ClickContinue.Thedialogboxdisplaysasummary.
g ClickCreateNowtocreatethefaultdomain.
h Repeatstepsbgasneededtocreateadditionalfaultdomains.
i
Whenyouarefinishedcreatingfaultdomains,clickReturn.TheFCtabappears.
3 ConfigureeachbackendFCport.
a SetthePurposefieldtoBackEnd.
b ConfirmthattheFaultDomainfieldissetto<none>.
c
(Optional)TypeadescriptivenameintheUserAliasfield.
4 ConfigureeachfrontendFCport.
a SetthePurposefieldtoFrontEndPrimaryorFrontEndReservedasappropriate.
b SettheFaultDomainfieldtotheappropriatefaultdomainthatyoucreated.
c
(Optional)TypeadescriptivenameintheUserAliasfield.
5 ConfigureeachportthatisunusedorusedforIPCbetweenstoragecontrollermodules.
a SetthePurposefieldtoUnknown.
b ConfirmthattheFaultDomainfieldissetto<none>.
c
Dell
(Optional)TypeadescriptivenameintheUserAliasfield.
41
1 ClicktheFCtab.
2 CreateafaultdomainforeachFCfabric.
a ClickEditFaultDomains.Thewizarddisplaysalistofthecurrentlydefinedfaultdomains.
b ClickCreateFaultDomain.Adialogboxappears.
c
IntheNamefield,typeanameforthefaultdomain.
d FromtheTypedropdownmenu,selectFC.
e (Optional)IntheNotesfield,typeadescriptionofthefaultdomain.
f
ClickContinue.Thedialogboxdisplaysasummary.
g ClickCreateNowtocreatethefaultdomain.
h Repeatstepsbgasneededtocreateadditionalfaultdomains.
i
Whenyouarefinishedcreatingfaultdomains,clickReturn.TheFCtabappears.
3 ConfigureeachbackendFCport.
a SetthePurposefieldtoBackEnd.
b ConfirmthattheFaultDomainfieldissetto<none>.
c
(Optional)TypeadescriptivenameintheUserAliasfield.
4 ConfigureeachfrontendFCport.
a SetthePurposefieldtoFrontEnd.
b SettheFaultDomainfieldtotheappropriatefaultdomainthatyoucreated.
c
(Optional)TypeadescriptivenameintheUserAliasfield.
5 (Optional)Changethepreferredphysicalportforoneormorevirtualports.
a ClickEditVirtualPorts.Thewizarddisplaysalistofvirtualports.
b Foreachvirtualportthatyouwanttomodify,selectthepreferredphysicalportInthePreferred
PhysicalPort.
Dell
42
Whenyouarefinished,clickApplyChanges.
6 ConfigureeachportthatisunusedorusedforIPCbetweenstoragecontrollermodules.
a SetthePurposefieldtoUnknown.
b ConfirmthattheFaultDomainfieldissetto<none>.
(Optional)TypeadescriptivenameintheUserAliasfield.
2 ConfigureeachbackendSASport.
a SetthePurposefieldtoBackEnd.
b ConfirmthattheFaultDomainfieldissetto<none>.
c
(Optional)TypeadescriptivenameintheUserAliasfield.
3 ConfigureeachportthatisunusedorusedforIPCbetweenstoragecontrollermodules.
a SetthePurposefieldtoUnknown.
b ConfirmthattheFaultDomainfieldissetto<none>.
c
Dell
(Optional)TypeadescriptivenameintheUserAliasfield.
43
UsetheGenerateSSLCertpagetogenerateanewSecureSocketLayer(SSL)certificateorimportanexisting
certificatefortheSC4020.TheSSLcertificatemustmatchtheSC4020sIPAddressorDNShostname.
TheinitialcertificateshippedwiththeSC4020maynotmatchtheIPaddressorDNShostnameassignedto
theSC4020.Ifthisisthecase,whenconnectingtoSC4020,amessageisdisplayedidentifyingamismatch
betweenthecertificateandtheIPaddressorDNShostnameoftheSC4020.Importorgenerateacertificate
tocorrectthis.
Caution: DonotclickSkiptobypassthispage.ClickingSkipcanresultinconnectiondisruptions
toStorageCenterSystemManager.
Dell
44
Import a Certificate
IfanSSLcertificatehasalreadybeengenerated,importthecertificate.
Prerequisites
Thepublickeyfilemustbeinx.509format.
Steps
1 ClickImport.Afilebrowserappears.
2 Browsetothelocationofthepublickey(*.pem)fileandselectit.
3 ClickNext.
4 Browsetothelocationoftheprivatekeyfile(*.pem).
5 ClickNext.ASummarypageappearsthatidentifiesthekeyfilesselected.
6 ClickSavetoimportthecertificates.
Dell
45
1 ClickGenerate.ThewizardpromptsyoutoentertheIPaddressesandhostnamesfortheStorage
Center.
2 Inthetextfield,enterallDNShostnames,IPv4addresses,andIPv6addressesforthisSC4020,separated
bycommas.Thewizardprepopulatesthefieldwithinformationitknows,butitislikelythatmoresite
specifichostnamesandaddressesneedtobeentered.
Caution: ThehostnamesandaddressesmustmatchthisStorageCenteroryouwillnotbeable
toreconnecttoit.
3 ClickGenerateNow.Anewcertificateisgeneratedandthesessionends.Tocontinue,refreshthe
browserandlogontotheSC4020again.
Dell
46
3 LogintoStorageCenterSystemManager.
4 DefinetheserverinSystemManager.
a IntheSystemTree,selectServers.
b ClickCreateServer.TheCreateServerwizardappears.
c
SelecttheserverHBAsinthetable,thenclickContinue.
d IntheNamefield,typeanamefortheserver.
e FromtheOperatingSystemdropdownmenu,selecttheoperatingsystemthattheserverisrunning.
f
ClickContinue.Thewizarddisplaysasummary.
g ClickCreateNow.Thewizarddisplaysalistofoptionalactions.
h ClickClose.Thewizardcloses.
5 Createa25GBtestvolumecalledTestVol1.
a IntheSystemTree,selectVolumes.
a IntheCreateServerwizard,clickCreateVolume.TheCreateVolumewizardappears.
b Setthevolumesizeto25GB,thenclickContinue.
c
ClickContinuetoapplythedefaultReplayProfile.
d TypeTestVol1intheNamefield,thenclickContinue.Thewizarddisplaysasummary.
e ClickCreateNow.Thewizarddisplaysalistofoptionalactions.
f
ClickClose.
6 RepeatStep 5tocreateasecondtestvolumenamedTestVol2.
7 MapTestVol1tostoragecontrollermodule1.
a IntheSystemTree,expandtheVolumesnode.
b SelectTestVol1.
c
ClickMapVolumetoServer.TheMapVolumetoServerwizardappears.
d Selecttheserver,thenclickContinue.Thewizarddisplaysasummary.
e ClickAdvanced.Thewizarddisplaysadvancedmappingoptions.
f
IntheRestrictMappingPathsarea,selecttheMaptocontrollercheckbox,thenselectthestorage
controllermodulefromthedropdownmenu.
g ClickContinue.Thewizarddisplaysasummary.
h ClickCreateNow.Themappingiscreatedandthewizardcloses.
8 RepeatStep 7tomapTestVol2tostoragecontrollermodule2.
9 Ontheserver,partitionandformatthetestvolumes.
Dell
47
a CopytheTestfoldertotheTestVol1volume.
b Duringthecopyprocess,shutdownstoragecontrollermodule1(thestoragecontrollermodule
throughwhichthevolumeismapped).
c
Verifythatthecopyprocesscontinuesafterthestoragecontrollermoduleisshutdown.
d Afterthecopyfinishes,turnonthestoragecontrollermodule.
e Wait3minutesandverifythatthestoragecontrollermodulehasfinishedstarting.
f
Rebalancetheports.
3 Manuallyshutdownstoragecontrollermodule2whilecopyingdatatoTestVol2toverifythatIOisnot
interruptedbythefailoverevent.
a CopytheTestfoldertotheTestVol2volume.
b Duringthecopyprocess,shutdownstoragecontrollermodule2(thestoragecontrollermodule
throughwhichthevolumeismapped).
c
Verifythatthecopyprocesscontinuesafterthestoragecontrollermoduleisshutdown.
d Afterthecopyfinishes,turnonthestoragecontrollermodule.
e Wait3minutesandverifythatthestoragecontrollermodulehasfinishedstarting.
f
Rebalancetheports.
Test MPIO
IfthenetworkenvironmentandserversareconfiguredforMPIO,performteststomakesurethatfailed
pathsdonotinterruptIO.
1 CreateaTestfolderontheserverandcopyatleast2GBofdataintoit.
2 MakesurethattheFCserverisconfiguredtouseloadbalancingMPIO(roundrobin).
3 ManuallydisconnectapathwhilecopyingdatatoTestVol1toverifythatMPIOisfunctioningcorrectly.
a CopytheTestfoldertotheTestVol1volume.
b Duringthecopyprocess,disconnectoneofthepathsandverifythatthecopyprocesscontinues.
c
Reconnecttheport.
4 RepeatStep 3asnecessarytotestadditionalpaths.
5 RestartthestoragecontrollermodulethatcontainstheactivepathwhileIOisbeingtransferred.
6 IftheStorageCenterisnotinaproductionenvironment,restarttheswitchthatcontainstheactivepath
whileIOisbeingtransferred.
Dell
48
2 SelectAdminandclickContinue.
3 EnteranewpasswordintheEnterPasswordandReenterPasswordfields.
4 ClickOK.
2 SelectUsePhoneHomeProxyServerandenterthefollowing:
ProxyServerAddress:EntertheIPaddressoftheproxyserver.
Port:EntertheTCPportnumberoftheproxyserver.
ProxyUserName:Entertheusernamefortheproxyserver.
ProxyPassword/ConfirmPassword:Passwordfortheproxyserver.
3 ClickOK.
Dell
49
Phone Home
CompletesetupbysendingSC4020configurationinformationtoDellTechnicalSupportServiceswith
PhoneHome.
PhoneHomesendsacopyofaSC4020configurationtoDellTechnicalSupportServicestoenablethemto
supportaSC4020.TheinitialconfigurationissenttoDellTechnicalSupportServiceswhenSC4020is
installed.
Prerequisites
TCPports22and443mustbeallowedoutboundtotheInternet.
IfthenetworkrequireshoststouseaproxyservertoreachtheInternet,theStorageCentermustbe
configuredtouseaPhoneHomeproxy.
Steps
1 FromtheStorageManagementmenu,selectSystemPhoneHomePhoneHome.ThePhone
Homewizardstarts,listinganypreviousPhoneHomeevents.
2 ClickPhoneHomeNow.ThePhoneHomeInProgressdialogboxisdisplayed.
3 ClickOK.
4 WhentheStatecolumnlistsallitemswithSuccess,clickClose.
Dell
50
2 ClickCheckNow.AsStorageCenterchecksforupdates,statusappearsontheUpdateStatuspage.
3 Ifanupdateisavailable,installtheupdatefollowingtheinstructionsintheStorageCenterSystemUpgrade
Guide.
Next Steps
Afterinstallationiscomplete,youmightwanttoperformsomebasictaskstoconfigureStorageCenterfor
yourenvironment.Thesetasksareconfigurationdependentsosomemightnotapplytoyoursite.
SeetheStorageCenterAdministratorsGuidefordetailedconfigurationinstructions,includinghowto:
SetstoragecontrollermoduleandsystemIPaddressesforIPv6(ThismustbedoneifusingIPv6
addressing)
Manageunmanageddisks
AddStorageCenterusers;includingconfiguringLightweightDirectoryAccessProtocol(LDAP)
Configurepasswordrulesforlocalusers.
Createservers
ConfigureUserVolumeDefaults
AddStorageCentervolumes
Addaloginmessage
Troubleshooting
Thisappendixcontainstroubleshootingstepsforcommonproblems.
Possible Reason
Unabletoconnecttoastorage Communicationproblems.
controllermodulewitha
serialconnection
Solution
Reseatorreplacecables.
Verifythetelnetsettings.
Possible Reason
NoDisksFoundbyStartup
Wizard:
Needtoupdatesoftwareand/or 1 ClickQuit.
firmwaretousedrives
2 CheckforStorageCenterUpdatesonpage 51
Nodiskscouldbefound
attachedtothisDell
CompellentStorageCenter.
ExpectedDisksareMissing
Dell
Solution
3 CompletetheStartupWizardonpage 19.
Needtoupdatesoftwareand/or 1 CheckdriveLEDs.
firmwaretousedrives.
2 CheckforStorageCenterUpdatesonpage 51.
51
Troubleshooting Licenses
Issue
Possible Reason
Solution
Error:Thelicensefileisnot
valid(couldbeoldlicense
file).ContactDellTechnical
SupportServicesforanew
licensefile.
Canhappenwithadual
controllerStorageCenterif
thereisanattempttoapplythe
licensefilebeforethestorage
controllermodulesarejoined
andthelicensefileisappliedto
thestoragecontrollermodule
withthewrongserialnumber.
MakesurethatallthestepsinSetUpSoftware
CenterSoftwareonpage 12arefollowedinorder
andtryagain.
MakesuretoconnecttotheIPaddressofthe
storagecontrollermodulewiththelowerserial
number.
Makesuretheserialnumberinthenameofthe
licensefilematchesthestoragecontroller
module.
Troubleshooting Updates
Issue
Possible Reason
Solution
CannotcompleteStartup
Yournetworkmightemploya 1 EstablishaserialconnectiontotheStorage
Wizardandcannotcheckfor proxyserver,ConfigurePhone
Center.
updates
HomeProxyServerUsingthe 2 Runthefollowingcommands:
CommandLineInterface(CLI).
mc values set UsePhHomeProxy true
mc values set PhHomeProxyString
[proxy server IP address]
mc values set PhHomeProxyUserName
[proxy server user name]
mc values set PhPomeProxyPassword
[proxy server password]
3 CheckforStorageCenterUpdatesonpage 51.
4 CompletetheStartupWizardonpage 19.
Dell
52