SC4020 Qualification Units Deployment Guide

Qualification Units OnlyFebruary 14, 2014

TheSC4020QualificationUnitsDeploymentGuidedescribeshowtoinstallandconfigureSC4020
qualificationunits.

Contents
PreparingforInstallation .................................................................... 1
InstallingtheHardware ..................................................................... 2
BackEndConnections ....................................................................... 6
FrontEndConnections ...................................................................... 6
SetUpSoftwareCenterSoftware ............................................................. 12
PerformPostSetupTasks ................................................................... 46
Troubleshooting ........................................................................... 51

Preparing for Installation


Makesurethatthecorrectequipmentisavailable,theinstallationenvironmentisready,andyouhavethe
necessarymaterials.

Unpack and Inventory the Storage Controller Hardware


MakesuretheStorageControllerequipmentthatwasorderedarrivedsafelyonsite:

StorageSystemEnclosurewithtwoinstalledStorageControllerModules

TwoBatteryBackupUnits(BBU)

DellEnterprisePlusDrivesandDriveBlanks

Railkit

TwoPowerCables

Twoserialcables

TwoSAScables

FibreChannelcables

Ethernetcables

Prepare the Installation Environment


Makesurethattheenvironmentisreadyforinstallation.

RackSpace:Theremustbesufficientspaceintheracktoaccommodatethestoragecontroller.

Power:Powermustbeavailableintherack,andthepowerdeliverysystemmustmeetthepower
requirementsforthestoragecontroller.

Connectivity:Therackmustbewiredforconnectivitytothemanagementnetworkandanynetworksthat
carryfrontendIOfromthestoragecontrollertoservers.

Dell

Dell Internal Use Only Confidential

Gather Required Materials

Qualification Units OnlyFebruary 14, 2014

Makesurethatyouhavethefollowingitemsbeforeyoubegintheinstallation.
Required Item

Description

StorageCenterlicensefile

ControlswhichStorageCenterfeaturesareenabled.

HardwareSerialNumber(HSN)
andSystemSerialNumber(SSN)

Serialnumbersusedtoconfigurethestoragecontrollermodules.

LaptopwithRS232serialportor
USBport

Usedtoruncommandsandviewconsolemessagesduringstoragecontroller
moduleconfiguration.

Computerconnectedtothesame
managementnetworkasthe
storagecontrollermodule

UsedtoconnecttotheStorageCenterSystemManager(throughawebbrowser)
tocompletethestoragecontrollermoduleconfiguration.

Installing the Hardware


Alwaysfollowstandardsafetyprecautionswheninstallinghardwaretoavoidinjuryanddamagetothe
equipment.

Mount Storage System Enclosure in Rack


Dellrecommendsmountingthestoragesystemenclosureinaracktoensuresafetyandtoallowfor
expansion.
1 Assembletherailsfollowingthesafetyinstructionsandtherackinstallationinstructionsprovidedwith
yoursystem.
2 Installnetworkswitches,asapplicable.
3 InstalltheSC4020chassisintotherack.

Figure 1. Mount Storage System Enclosure


4 Securethestoragesystemenclosuretotherack.
a Openthelatchoneachchassiseartodisplaythemountingbolts.
b Screwtheboltsintotherack.
c

Dell

Closethelatchoneachchassisear.

Dell Internal Use Only Confidential

Install Drives in Storage System Enclosure


TheSC4020storagesystemenclosuresupportsupto242.5DellEnterprisePlusdrives.Aminimumofsix
drivesisrequired.
1 Startingwithslot0ontheleftsideofthestoragesystemenclosure,opentheharddrivecarrierhandle
andinserttheharddrivecarrierintotheharddrivebay.

Qualification Units OnlyFebruary 14, 2014

2 Slidethedriveintothebayuntilthecarriercontactsthebackplane.
3 Closetheharddrivecarrierhandletolocktheharddriveinplace.
4 Continuetopushfirmlyuntilyouhearaclickandthehandlefullyengages.

Dell

Dell Internal Use Only Confidential

Qualification Units OnlyFebruary 14, 2014

5 Whentheenclosureisturnedonandthedrivesspinup,makesurethatthedriveLEDsareon(green),
indicatingnormalconditions.

Figure 2. Dell Enterprise Plus Drive


Item

Name

Description

Harddriveactivityindicator Flashinggreen:Indicatesdriveactivity
Steadygreen:Indicatesnodriveactivity

Harddrivestatusindicator

Steadygreen:Normaloperation
Flashinggreen(on1sec/off1sec):DriveindicatorissettoOninSystem
Manager.
Off:Nopowertothedrive

Install Battery Backup Unit in Storage Controller Modules


ThebatterybackupunitallowstheSC4020tosavecachetoflashpersistentmemoryuponreceivingapower
failureindication.
Warning: Installinganincompatiblebatterybackupunitmayincreasetheriskoffireorexplosion.
Observethefollowingprecautions:

Dell

ThebatterybackupunitshouldonlybereplacedwithaBBUthatisthesameorequivalentasthe
factoryinstalledBBU.

DonotattempttoopenorservicetheBBU.DonotdisposeoftheBBUinafireorwithhousehold
waste.Contactthelocalwastedisposalagencyforthelocationofthenearestbatterydepositsite.

Dell Internal Use Only Confidential

Qualification Units OnlyFebruary 14, 2014

1 AlignaBBUwithstoragecontrollermodule1.

Figure 3. Storage Controller Module Battery Backup Unit


1 Battery Backup Unit

2 Release tab

3 Storage Controller Module 1

2 LiftthereleasetabandslidetheBBUintothestoragecontrollermoduleuntilitlocksinplace.
3 AlignaBBUwithstoragecontrollermodule2.
4 LiftthereleasetabandslidetheBBUintothestoragecontrollermoduleuntilitlocksinplace.
5 Whentheenclosureisturnedon,makesurethatthebatterybackupunitLEDsareon(green),indicating
normalconditions.

Figure 4. Battery Backup Unit LEDs


Item

Name

Description

Armedindicator

Steadygreen:Armed
Flashinggreen(1beaton/3beatsoff):Notarmedandcharging
Flashinggreen(2beatson/2beatsoff):Notarmedandnotcharging

Faultindicator

Steadyamber:Batteryfault
Off:Nofault

Dell

Dell Internal Use Only Confidential

Back-End Connections
CreateanIPCdirectconnectionbeconnectionSAScablebetweenthestoragecontrollermodules.

Create SAS IPC Connection Between the Storage Controller Modules

Qualification Units OnlyFebruary 14, 2014

AddSAScablingbetweentheinitiatorandtargetportsofeachstoragecontrollermodule.
1 ConnectaSAScablebetweenstoragecontrollermodule1,portAandstoragecontrollermodule2,
portB.
2 ConnectaSAScablebetweenstoragecontrollermodule1,portAandstoragecontrollermodule2,
portB.

Figure 5. SAS IPC Connection


1 Storage Controller Module 1

2 Storage Controller Module 2

3 LabelbothendsofeachSAScablewithIPClabels.

Figure 6. Labels for IPC Connection

Front-End Connections
FrontendconnectionsrefertotheFibreChannelconnectionsbetweentheSC4020andtheserver.Dell
CompellentrecommendsconnectingserverstotheSC4020usingthemostredundantoptionsavailable.

Types of Redundancy for Front-End Connections


Frontendredundancyisachievedbyeliminatingsinglepointsoffailurethatcouldcauseaservertolose
connectivitytotheStorageCenter.
DependingonhowtheStorageCenterisconfigured,thefollowingtypesofredundancyareavailable.

Pathredundancy:WhenmultiplepathsareavailablefromaservertoanSC4020,aserverconfiguredfor
multipathIO(MPIO)canusemultiplepathsforIO.Ifapathfails,theservercontinuestousethe
remainingactivepaths.

Storagecontrollermoduleredundancy:IfonestoragecontrollermodulefailsinanSC4020,thefront
endportsfailovertothefunctioningstoragecontrollermodule.Bothfrontendconnectivitymodes
(legacymodeandvirtualportmode)providestoragecontrollermoduleredundancy.

Dell

Dell Internal Use Only Confidential

Portredundancy:Invirtualportmode,ifaportgoesdownbecauseitisdisconnectedorthereisa
hardwarefailure,theportcanfailovertoanotherfunctioningportinthesamefaultdomain.Port
redundancyisavailableonlyforStorageCentersoperatinginvirtualportmode.

Qualification Units OnlyFebruary 14, 2014

Fibre Channel Zoning


WhenusingFibreChannelforfrontendconnectivity,zonesmustbeestablishedtoensurethatstorageis
visibletotheservers.Planthefrontendconnectivityusingzoningconceptsdiscussedinthissectionbefore
startingtocablethestoragecontrollermodules.
ZoningcanbeappliedtoeithertheportsonswitchesortotheWorldWideNames(WWNs)oftheend
devices.Zonesshouldbecreatedusingasingleinitiator(usingphysicalWWNs)andmultipletargets(using
virtualWWNs).
ThevirtualWWNsfromeachstoragecontrollermodulemustbeincludedinthezonewitheachhosts
WWN.
Note: Forvirtualportmode,WWNzoningisrecommended.

WWN Zoning Guidelines


WhenWWNzoningisconfigured,adevicemayresideonanyportorchangephysicalportsandstillbe
visiblebecausetheswitchisseekingaWWN.
Connectivity Type

Guidelines

Legacymode

IncludeallStorageCenterfrontendWWNsorportsinasinglezone.
Createserverzonesthatcontainasingleinitiatorandmultipletargets,and
whichincludetheserverHBAWWN.

Virtualportmode

IncludeallStorageCentervirtualWWNsinasinglezone.
IncludeallStorageCenterphysicalWWNsinasinglezone.
Createserverzonesthatcontainasingleinitiatorandmultipletargets(Storage
CentervirtualWWNs),andwhichincludetheserverHBAWWN.

FibreChannelreplication

IncludeallStorageCenterphysicalWWNsfromstoragecontrollermodule1
andstoragecontrollermodule2inasinglezone.
IncludeallStorageCenterphysicalWWNsofstoragecontrollermodule1and
thevirtualWWNsofstoragecontrollermodule2ontheparticularFabric.
IncludeallStorageCenterphysicalWWNsofstoragecontrollermodule2and
thevirtualWWNsofstoragecontrollermodule1ontheparticularFabric.
Note: Someportsmaynotbeusedordedicatedforreplication,howeverports
thatareusedmustbeinthesezones.

Port Zoning Guidelines


Whenportzoningisconfigured,onlyspecificswitchportsarevisible.Ifastoragedeviceismovedtoa
differentportthatisnotpartofthezone,itisnolongervisibletotheotherportsinthezone.
Connectivity Type

Guidelines

Legacymodeorvirtualportmode IncludeallStorageCenterfrontendports.
CreateserverzoneswhichcontainallStorageCenterfrontendportsanda
singleserverport.
FibreChannelreplication

Dell

IncludeallStorageCenterfrontendportsfromSystemAandSystemBina
singlezone.

Dell Internal Use Only Confidential

Legacy Mode with Single-Fabric Fibre Channel


ConnectalegacymodeFibreChanneltoasinglefabricifonlyoneFCswitchisavailableandyouwantto
protectagainststoragecontrollermodulefailure.

Qualification Units OnlyFebruary 14, 2014

Inthisconfiguration,twofaultdomainsarespreadacrossbothstoragecontrollermodules.Eachfault
domaincontainssetsofprimaryandreservepaths(P1R1andP2R2).Thereservedpathsprovide
redundancyforasinglestoragecontrollermodulefailure.Thisconfigurationisvulnerabletoswitchfailure.

Prerequisites
EachstoragecontrollermodulemusthavetwoavailableFCfrontendports.

Steps
1 ConnecteachFCservertotheFCfabric.
2 Connectfaultdomain1(showninorange)tofabric1.

PrimaryPortP1:StorageControllerModule1,Port1Fabric1

ReservedPortR1:StorageControllerModule2,Port1Fabric1

3 Connectfaultdomain2(showninblue)tofabric1.

PrimaryPortP2:StorageControllerModule2,Port2Fabric1

ReservedPortR2:StorageControllerModule1,Port2Fabric1

4 ConfigureFCzoningtomeetthelegacymodezoningrequirements.

Figure 7. Single-Fabric FC in Legacy Mode


1 Server 1

2 Server 2

3 Fabric (FC Switch)

4 Storage Controller Module 1

5 Storage Controller Module 2

Dell

Dell Internal Use Only Confidential

Legacy Mode with Dual-Fabric Fibre Channel

Qualification Units OnlyFebruary 14, 2014

UsetwofabricswithlegacymodetopreventanFCswitchfailureorstoragecontrollermodulefailurefrom
causinganoutage.
Inthisconfiguration,fourfaultdomainsarespreadacrossbothstoragecontrollermodules.Eachfault
domaincontainssetsofprimaryandreservepaths(P1R1,P2R2,P3R3,andP4R4).Toprovide
redundancy,theprimaryportandthecorrespondingreserveportinafaultdomainmustconnecttothe
samefabric.WhenMPIOisconfiguredontheFCservers,theprimarypathsprovideredundancyfora
singleportorcablefailure.Thereservedpathsprovideredundancyforstoragecontrollermodulefailures.

Prerequisites
EachstoragecontrollermodulemusthavetwoavailableFCfrontendportsforeachFCfabric.

Steps
1 ConnecteachFCservertobothFCfabrics.
2 Connectfaultdomain1(showninorange)tofabric1.

PrimaryPortP1:StorageControllerModule1,Port1Fabric1

ReservedPortR1:StorageControllerModule2,Port1Fabric1

3 Connectfaultdomain2(showninblue)tofabric1.

PrimaryPortP2:StorageControllerModule2,Port1Fabric1

ReservedPortR2:StorageControllerModule1,Port1Fabric1

4 Connectfaultdomain3(showningreen)tofabric2.

PrimaryPortP3:StorageControllerModule1,Port3Fabric2

ReservedPortR3:StorageControllerModule2,Port3Fabric2

5 Connectfaultdomain4(showninpurple)tofabric2.

PrimaryPortP4:StorageControllerModule2,Port4Fabric2

ReservedPortR4:StorageControllerModule1,Port4Fabric2

6 ConfigureFCzoningtomeetthelegacymodezoningrequirements.

Figure 8. Dual-Fabric FC in Legacy Mode


1 Server 1

2 Server 2

3 Fabric 1 (FC Switch)

4 Fabric 2 (FC Switch)

5 Storage Controller Module 1

6 Storage Controller Module 2

Dell

Dell Internal Use Only Confidential

Virtual Port Mode with Single-Fabric Fibre Channel

Qualification Units OnlyFebruary 14, 2014

ConnectvirtualportmodeFibreChanneltoasinglefabricifonlyoneFCisavailableandyouwantto
protectagainstportorstoragecontrollermodulefailure.
Inthisconfiguration,thereisonefaultdomainbecausethereisasingleFCfabric.Eachstoragecontroller
moduleisconnectedtothefabricbyatleasttwoFCconnectionstoprovideportredundancy.Ifasingleport
fails,itsvirtualportfailsovertoanotherport.Ifastoragecontrollermodulefails,thevirtualportsonthe
failedstoragecontrollermodulemovetoportsontheotherstoragecontrollermodule.Thisconfiguration
isvulnerabletoswitchfailure.

Prerequisites

EachstoragecontrollermodulemusthavetwoavailableFCfrontendports.

Therequirementsforvirtualportmodemustbemet.

Steps
1 ConnecteachservertotheFCfabric.
2 Connectfaultdomain1(showninorange)tofabric1.

StorageControllerModule1,Port1Fabric1

StorageControllerModule1,Port2Fabric1

StorageControllerModule2,Port1Fabric1

StorageControllerModule2,Port2Fabric1

3 ConfigureFCzoningtomeetthelegacymodezoningrequirements.

Figure 9. Single-Fabric FC in Virtual Port Mode


1 Server 1

2 Server 2

3 Fabric 1 (FC Switch)

4 Storage Controller Module 1

5 Storage Controller Module 2

Dell

Dell Internal Use Only Confidential

10

Virtual Port Mode with Dual-Fabric Fibre Channel

Qualification Units OnlyFebruary 14, 2014

UsetwofabricswithvirtualportmodetopreventanFCswitchfailureorstoragecontrollermodulefailure
fromcausinganoutage.
Inthisconfiguration,thereisonefaultdomainforeachFCfabric.Eachstoragecontrollermoduleis
connectedtobothfabricsbytwoFCconnections.Ifasingleportfails,itsvirtualportfailsovertoanother
portinthesamefaultdomain.Ifastoragecontrollermodulefails,thevirtualportsonthefailedstorage
controllermodulemovetoportsontheotherstoragecontrollermoduleinthesamefaultdomain.

Prerequisites

EachstoragecontrollermodulemusthavetwoavailableFCfrontendportsforeachFCfabric.

Therequirementsforvirtualportmodemustbemet.

Steps
1 ConnecteachservertobothFCfabrics.
2 Connectfaultdomain1(showninorange)tofabric1.

StorageControllerModule1,Port1Fabric1

StorageControllerModule1,Port2Fabric1

StorageControllerModule2,Port1Fabric1

StorageControllerModule2,Port2Fabric1

3 Connectfaultdomain2(showninblue)tofabric2.

StorageControllerModule1,Port3Fabric2

StorageControllerModule1,Port4Fabric2

StorageControllerModule2,Port3Fabric2

StorageControllerModule2,Port4Fabric2

4 ConfigureFCzoningtomeetthelegacymodezoningrequirements.

Figure 10. Dual-Fabric FC in Virtual Port Mode


1 Server 1

2 Server 2

3 Fabric 1 (FC Switch)

4 Fabric 2 (FC Switch)

5 Storage Controller Module 1

6 Storage Controller Module 2

Dell

Dell Internal Use Only Confidential

11

Set Up Software Center Software


ConnecttotheStorageCentermanagementinterfacesandconfiguretheStorageCentersoftware.

Qualification Units OnlyFebruary 14, 2014

Connect the Ethernet Management Ports


TheEthernetmanagementportofeachstoragecontrollermodulemustbeconnectedtoamanagement
network.TheEthernetmanagementinterfacesupportssystemloginandaccesstothemanagement
software.Itisalsousedtosendemail,alerts,SNMPtraps,andsystemdatausingPhoneHome.

Prerequisites
LocatetheEthernetmanagementcablesandmanagementlabelsthatshippedwiththeSC4020.
1 ConnectthemanagementportoneachstoragecontrollermoduletoanEthernetswitchorVLAN.

Figure 11. Ethernet Management Interface


1 Ethernet switch

2 Ethernet cable

3 Ethernet cable

4 Storage Controller Module 1

5 Storage Controller Module 2

2 LabelbothendsofeachEthernetmanagementcablewithmanagementlabels.

Figure 12. Management Cable Label

Turn on the Storage Controller


AllhardwaremustbeinstalledandcabledbeforeturningontheSC4020.Inaddition,theFCswitchesmust
beconfiguredandzonedbeforetheSC4020isconfigured.

Dell

Dell Internal Use Only Confidential

12

Caution: WhentheSC4020ispoweredon,thereisaoneminutedelaywhiletheSC4020
preparestoboot.Duringthistime,theonlyindicationthattheSC4020ispoweredonarethe
LEDsonthestoragecontrollermodules.Aftertheoneminutedelay,theSC4020fansandLEDs
turnonasanindicationthatthestoragecontrollermodulesarestartingtocomeup.

Qualification Units OnlyFebruary 14, 2014

1 EnsurethatthepowerswitchesareintheOFFpositionbeforeconnectingthepowercables.

Figure 13. Connect Power Cable


2 Connectthepowercablestothepowersupplyunits(PSUs)inthestoragesystemenclosure.
3 Plugtheotherendofthepowercablesintoagroundedelectricaloutletoraseparatepowersourcesuch
asanuninterruptedpowersupply(UPS)orapowerdistributionunit(PDU).
4 Securethepowercablesfirmlytothebracketusingthestrapprovided.

Figure 14. Secure the Power Cables


5 Simultaneouslypressbothpowerswitchesontherearofthestoragesystemenclosuretoturnonthe
SC4020.

Dell

Dell Internal Use Only Confidential

13

Qualification Units OnlyFebruary 14, 2014

Figure 15. Power on the SC4020

Configure the Storage Controller


Useserialconnectionstothestoragecontrollermodulestosettheinitialconfiguration.

Configure a Storage Controller Module


ConfigurethestoragecontrollermodulewiththeHSNandSSNprovidedinthepreinstallation
documents.Inaddition,configureanIPaddressforthemanagementinterface(eth0),specifyoneormore
DNSservers,andsetthedomainnametowhichtheStorageCenterbelongs.

Prerequisites

eth0supportssystemloginandaccessforthesoftware.Itisusedtosendemails,alerts,SNMPtraps,and
PhoneHomedata.

eth1isusedfordedicatedInterprocessCommunication(IPC)betweenstoragecontrollermodules.
Becauseeth1isdirectlyconnectsbothstoragecontrollermodules,nodefaultgatewayisrequired.
Caution: Donotchangetheeth1addressunlessbothstoragecontrollermoduleswerefactory
configuredwiththesameaddressorthecustomerrequeststhechange.Theeth1addresscannot
resideinthesamesubnetaseth0.

Steps
1 Usethesuppliedserialcable(RS232to3.5mmminiconnector)toconnectfromaPCorlaptoptoa
storagecontrollermodule.(ToconnectfromaUSBportonaPCorlaptop,useaUSBtoRS232
converter.)
2 OpenaterminalemulatororacommandlineinterfaceonthePCorlaptop.
3 Configuretheconnectionasshowninthefollowingtable.

Dell

Setting

Value

Emulation

VT220

ColumnMode

132

LineWrapping

Off

Connection

SerialPort

ConnectionType

Direct

BaudRate

115,200

Dell Internal Use Only Confidential

14

Qualification Units OnlyFebruary 14, 2014

Setting

Value

Parity

None

DataBits

StopBits

FlowControl

Hardwareordefault

Note: Tofacilitatetroubleshooting,enableloggingforthesession.
4 PresstheEnterkeyseveraltimestoinitiatetheconnection.Theterminaldisplaystheprompt
<SafeMode> sn0>toindicatethatthestoragecontrollermoduleisinSafeMode.
5 Runthefollowingcommandtoentertheshellacessdevelopermode.
shellaccess developer

6 Performthefollowingstepstospecifytherequiredprejoinconfigurationinformationonstorage
controllermodule1(leaderstoragecontrollermodule):
a Runthefollowingcommandtodisplaytheprejoinconfigurationinformationthatmustbespecified.
platform prejoin show

Example:
<SafeMode> sn0> platform prejoin show
****************************************************************
Prejoin configuration:
Item

Local controller

Remote controller

-----------Canister
SSN
HSN
eth0 IPv4
eth0 IPv6
eth1 IPv4
eth1 IPv6
gateway IPv4
gateway IPv6
Domain
DNS Server 0
DNS Server 1

-------------------------------0
0
0
10.0.10.225/8
::/128
169.254.0.100/16
::/128
0.0.0.0
::

-------------------------------1
0
0
0.0.0.0/32
::/128
169.254.0.101/16
::/128
0.0.0.0
::

0.0.0.0
0.0.0.0

0.0.0.0
0.0.0.0

****************************************************************
SSN not configured.
Local HSN not configured.
When all issues identified above are corrected, type:
'-sm -go'
to continue normal processing.
****************************************************************

b RunthefollowingcommandstosettheHSNandSSNusingtheSSNprovidedinthepreinstallation
documents.

Dell

Dell Internal Use Only Confidential

15

platform init hsn set [lower SSN]


platform init ssn set [lower SSN]

Example:
platform init hsn set 10001
platform init ssn set 10001

Qualification Units OnlyFebruary 14, 2014

RunthefollowingcommandtospecifyanIPaddressandsubnetmaskforthemanagementinterface
(eth0).
ifconfig inet eth0 [IPaddress]/[prefixlength]

Example:
ifconfig inet eth0 198.51.100.99/24

d Runthefollowingcommandtospecifythegatewayaddress.
ifconfig inet gateway [gatewayaddress]

Example:
ifconfig inet gateway 198.51.100.1

e Runthefollowingcommandtospecifythedomainname.
ifconfig domainname [domain name]

Example:
ifconfig domainname corp.dom

RunthefollowingcommandtospecifyoneormoreDNSservers.
net dns init [DNS server 1] [DNS server 2]

Example:
net dns init 203.50.113.55 203.50.113.90

g Runthefollowingcommandtoverifythattheprejoinconfigurationinformationiscomplete.
platform prejoin show

h Runthefollowingcommandtosavechangestotheconfiguration.
ifconfig save

Runthefollowingcommandtoexitsafemodeandrebootthestoragecontrollermodule.
-sm -go

Note: Thestoragecontrollermoduletakesseveralminutestorebootanditmayrebootmore
thanoncethisisnormal.
7 Performthefollowingstepstospecifytherequiredprejoinconfigurationinformationonstorage
controllermodule2(peerstoragecontrollermodule):
a Runthefollowingcommandtodisplaytheprejoinconfigurationinformation.
platform prejoin show

Example:
<SafeMode> sn0> platform prejoin show
****************************************************************
Prejoin configuration:

Dell

Item

Local controller

-----------Canister
SSN

-------------------------------1
0

Remote controller
-------------------------------0
0

Dell Internal Use Only Confidential

16

Qualification Units OnlyFebruary 14, 2014

HSN
eth0 IPv4
eth0 IPv6
eth1 IPv4
eth1 IPv6
gateway IPv4
gateway IPv6
Domain
DNS Server 0
DNS Server 1

0
10.0.10.173/8
::/128
169.254.0.101/16
::/128
0.0.0.0
::

0
0.0.0.0/32
::/128
169.254.0.100/16
::/128
0.0.0.0
::

0.0.0.0
0.0.0.0

0.0.0.0
0.0.0.0

****************************************************************
SSN not configured.
Local HSN not configured.
When all issues identified above are corrected, type:
'-sm -go'
to continue normal processing.

b RunthefollowingcommandstosettheHSNandSSNusingtheSSNprovidedinthepreinstallation
documents.
platform init hsn set [higher SSN]
platform init ssn set [higher SSN]

Example:
platform init hsn set 10002
platform init ssn set 10002

RunthefollowingcommandtospecifyanIPaddressandsubnetmaskforthemanagementinterface
(eth0).
ifconfig inet eth0 [IPaddress]/[prefixlength]

Example:
ifconfig inet eth0 198.51.100.100/24

d Runthefollowingcommandtospecifythegatewayaddress.
ifconfig inet gateway [gatewayaddress]

Example:
ifconfig inet gateway 198.51.100.1

e Runthefollowingcommandtoverifythattheprejoinconfigurationinformationiscomplete.
platform prejoin show

Runthefollowingcommandtosavechangestotheconfiguration.
ifconfig save

g Runthefollowingcommandtoexitsafemodeandrebootthestoragecontrollermodule.
-sm -go

Note: Thecontrollermoduletakesseveralminutestorebootanditmayrebootmorethan
oncethisisnormal.

Running the Storage Center Startup Wizard


UseawebbrowseronacomputerwithnetworkaccesstotheStorageCentertoaccessStorageCenter
SystemManagerandlaunchtheStartupWizard.

Dell

Dell Internal Use Only Confidential

17

Prerequisites
YoumusthaveacomputerthathasconnectivitytotheStorageCentermanagementinterface.Thecomputer
musthavethefollowingsoftwareinstalled:

Qualification Units OnlyFebruary 14, 2014

Oneofthefollowingsupportedwebbrowsers(otherbrowsersandversionsmayhavelimited
compatibility):

MicrosoftWindowsInternetExplorerVersions7,8,and9

MicrosoftWindowsInternetExplorer10and11onthedesktop(InternetExplorer10and11Modern
versionisnotsupported)

MozillaFirefoxonMicrosoftWindows

The32bit(x86)JavaRuntimeEnvironmentmustbeinstalledtorunStorageCenterSystemManagerin
any32bitbrowser.

Steps
1 Useasupportedwebbrowsertoconnecttotheeth0IPaddressorhostnameofstoragecontroller
module1.
2 Acknowledgeanysecuritymessages.
Note: Securitymessagesthatappearmaydifferdependingonthebrowserused.(ClickContinue
tothiswebsiteinInternetExploreroraddasecurityexceptioninFirefox.)
TheStorageCenterLoginpageappears.

3 Enterthedefaultusernameandpassword:

User:Admin

Password:mmm
Note: Theusernameandpasswordarecasesensitive.

4 ClickLogin.

Dell

Dell Internal Use Only Confidential

18

5 Ifthepasswordexpiredpageappears,enteranewpasswordfortheAdminuser:
a EntertheoldpasswordintheOldPasswordfield
b EnteranewpasswordintheNewPasswordandConfirmPasswordfields.
c

ClickLogin.ThepasswordischangedandyouareloggedintotheStorageCenterSystemManager.

Qualification Units OnlyFebruary 14, 2014

6 Ifprompted,clickYestoacknowledgecertificatemessages.
TheStartupWizardappearsanddisplaystheSoftwareEndUserLicenseAgreement(EULA).

Complete the Startup Wizard


UsetheStartupWizardtoconfiguretheStorageCenter.Thewizardcontainsthefollowingpages.

License Agreement Page


UsetheLicenseAgreementpagetoreadandaccepttheDellEndUserLicenseAgreement(EULA).
1 EnterinformationfortherequiredApprovingCustomerNameandApprovingCustomerTitlefields.
ThenameandtitleoftheapprovingcustomerandtheapprovaldatearerecordedandsenttoDell
TechnicalSupportServicesusingPhoneHome.
Note: TheEndUserLicenseAgreementisalsodisplayedthefirsttimeanynewuserlogsonto
theStorageCenter.Whendisplayedforanewuser,theEULAdoesnotrequireacustomername
ortitle.
2 AfterreadingtheEULA,clickAccepttocontinuewithsetup.TheLoadLicensepageappears.

Load License Page


UsetheLoadLicensepagetouploadtheStorageCenterlicensefile.Thelicensefilemakessettingsavailable
dependingonwhatfeatureswerepurchased.
1 Browsetothelocationofthelicensefile.
2 Verifythattheserialnumberofthelicensefilematchestheserialnumberofthestoragecontroller
modulebycomparingthenameofthelicensefiletothetitlebaroftheStartupWizard.
Licensefilesusethenamingconventionsnxxx_35_date.lic,where:

snxxxistheserialnumberoftheStorageCenter.

35indicatesthatthesystemrunssoftwarehigherthanversion3.5.

dateshowsthelicensegenerationdateinYYMMDDformat.

.licisthefileextension.

Dell

Dell Internal Use Only Confidential

19

Qualification Units OnlyFebruary 14, 2014

3 Selectthelicensefile,thenclickLoadLicense.TheStartupWizarddisplaysamessagewhenthelicense
issuccessfullyloaded.

Ifthelicenseloadssuccessfully,themessageThelicensesubmissionhascompletedsuccessfully
appears.

IfthemessageError:Thelicensefileisnotvalidmessageisdisplayed,seeTroubleshootingLicenses
onpage 52.

4 ClickContinue.TheCreateDiskFolderpageappears.

Dell

Dell Internal Use Only Confidential

20

Create Disk Folder Page


UsetheCreateDiskFolderpagetoassigndiskstoafolderinordertocreateasinglepoolofstoragefor
volumes.

Qualification Units OnlyFebruary 14, 2014

Note: IftheNodiskscouldbefoundmessageisdisplayed,seeTroubleshootingStorageSystem
Enclosuresonpage 51.
1 Selectdisksforthediskfolder.Bydefault,theStartupWizardselectsallavailabledisks.

a ScrollthroughthelistlookingatthePositionorNamecolumntoverifythatalltheexpecteddisks
arelisted.
Ifdisksaremissing,theissuesmightbefixedbyfollowingTroubleshootingStorageSystem
Enclosuresonpage 51.
b (Optional)Fromthelistofdisks,selectdiskstoincludeinthediskfolder.Bydefault,alldisksare
selected.

Toexcludeindividualdisksfromthediskfolder,clearthecorrespondingcheckboxes.

Toincludeindividualdisksinthediskfolder,clickUnselectAllandthenselecttheindividual
disksinclude.

Toselectalldisks,clickSelectAll.
Note: DellCompellentrecommendsselectingallavailablediskstomaximizethebenefitsof
DataProgression.

Dell

ClickContinue.TheStartupWizarddisplaysaprompttoselectdiskstodesignateashotspares.

Dell Internal Use Only Confidential

21

Qualification Units OnlyFebruary 14, 2014

2 ReviewthehotsparedisksselectedbytheStartupWizard.
Ahotsparediskisheldinreserveuntiladiskfails,atwhichpointthehotsparereplacesthefaileddisk.
Thehotsparediskmustbeaslargeorlargerthanthelargestdiskofitstypeinthediskfolder.
a (Optional)Changetheselectionbyselectingorclearingdiskstobeusedashotspares.
b ClickContinue,andifprompted,clickOKtoconfirm.TheStartupWizarddisplaysasummaryof
thediskfolderthatwillbecreated.

3 (Optional)ModifythedefaultfoldernameandenteradescriptionintheNotesfield.
4 (Optional)ClickAdvancedtoconfigureadvanceddiskfolderoptions.Thewizarddisplaysoptionsfor
redundancyanddatapagesize.

Dell

Dell Internal Use Only Confidential

22

Qualification Units OnlyFebruary 14, 2014

Note: Thedefaultmanageddiskfoldersettingsareappropriateformostsites.Ifyouare
consideringchangingthedefaultsettings,contactDellTechnicalSupportServicesforadvice.

a SelectPrepareDiskFolderforredundantstorage.
b ConfiguretheTierRedundancyforeachtier.
Theredundancylevelforeachtierdefaultstoeithersingleredundantordualredundantdepending
uponthedisksexpectedtobefoundinthetier.Ifatiercontainsatleastsixmanageddisksofwhich
oneis900GBorgreater,thenthattierandalltiersbelowitaresettodualredundantstorageby
default.Ifatiercontainsatleastsixmanageddisksof1.8TBorgreater,thenthattierandalltiers
belowitaresettodualredundantstorageandcannotbechanged.
Singleredundantstorageprotectsagainstthelossofanyonedrive.

RAID10(eachdiskismirrored)

RAID55(4datasegments/1paritysegmentperstripe)

RAID59(8datasegments/1paritysegmentperstripe)

Dualredundantstorageprotectsagainstthelossofanytwodrives:

Dell

RAID10DualMirror(dataiswrittensimultaneouslytothreeseparatedisks)

RAID66(4datasegments/2paritysegmentsperstripe)

RAID610(8datasegments/2paritysegmentsperstripe)

FromtheDatapageSizedropdownmenu,chooseadatapagesize.

2MB:(Default)Recommendedformostapplicationneeds.

512KB:Appropriateforapplicationswithhighperformanceneeds(suchascertaindatabases)or
environmentsinwhichReplaysaretakenfrequentlyunderheavyIO.Selectingthissizereduces
theamountofspacetheSystemManagercanpresenttoservers.

4MB:AppropriateforsystemsthatusealargeamountofdiskspacewithinfrequentReplays
(suchasvideostreaming).

Dell Internal Use Only Confidential

23

Qualification Units OnlyFebruary 14, 2014

Caution: Whenconsideringusingeitherthe512KBor4MBdatapagesettings,itis
recommendedthatyoucontactDellTechnicalSupportServicesforadviceonbalancing
resourcesandtounderstandtheimpactonperformance.
d ToconfigurethediskfoldertouseRAID0,selectthePrepareforNonRedundantStoragecheckbox.
Nonredundantstoragedoesnotprotectdataintheeventofadiskfailure.Selectthisoptiononlyfor
datathatisbackedupsomeotherway.
e ClickContinue.
5 ClickCreateNow,andifprompted,clickOKtoconfirm.TheAddControllerpageappears.

Add Controller Page


Ifthestoragecontrollermodulesareconfiguredwiththecorrectprejoininformation,thestoragecontroller
modulesjointogetherautomaticallyandthefollowingpagesappear:

Dell

Dell Internal Use Only Confidential

24

Ifthestoragecontrollermodulesfailtojoinautomatically,usetheManuallyAddControllerpagetojointhe
storagecontrollermodules.
1 IftheIPv6addresssettingsofthestoragecontrollermodulearenotconfigured,theConfigurethe
LeaderControllersIPv6addressvaluespageappears.
IfthemanagementnetworkusesIPv6:

Qualification Units OnlyFebruary 14, 2014

a EntertheIPv6IPaddressintheIPv6Addressfield.
b EntertheIPv6prefixlengthinIPv6PrefixLengthfield.
c

EntertheIPv6gatewayaddressvaluesintheIPv6Gatewayfield.

d ClickContinue.
IfthemanagementnetworkdoesnotuseIPv6,clickSkipIPv6Configuration.
2 ClickAddController.Thewizardpromptsyouforinformationaboutthesecondstoragecontroller
module.
Note: Informationdisplayedinthefollowingfigureisforillustrationonly.Thevaluesdisplayed
areuniquetoeachStorageCenter.

3 Configurethefollowingfields:

ControllerID:TheHSNforstoragecontrollermodule2isincludedinthelicensefileandtheadd
controllerprocessusesthatvalueastheControllerIDandadifferentvaluecannotbeentered.Ifthe
HSNforstoragecontrollermodule2isnotinthelicensefile,entertheHSNvalue.Thedimmedbox
intheprecedingfigureindicatesthattheHSNwasinthelicensefilemakingtheControllerIDbox
unavailable.

Ether0Interface:EntertheIPv4Address,IPv4NetMask,IPv4Gateway,IPv6Address,IPv6Prefix
Length,IPv6GatewayfortheEther0interfaceoncontroller module2.

Ether1Interface:EntertheIPAddress,NetMask,andGatewayfortheEther1interface.UsetheIP
addressfromthecontroller showconsolecommandforstoragecontrollermodule2.(Usedfor
communicationbetweenstoragecontrollermodules.)

PrimaryDNSServer:EntertheIPaddressoftheprimaryDNSserver.

Dell

Dell Internal Use Only Confidential

25

SecondaryDNSServer:(Optional)EntertheIPaddressofasecondaryDNSserver.

DomainName:(Optional)Enterthedomainnameforthestoragecontroller.

4 ClickContinue.

Qualification Units OnlyFebruary 14, 2014

TheStartupWizarddisplaysamessagethatdataandconfigurationinformationonthesecondstorage
controllermodulewillbelostandasksforconfirmation.

5 ClickJoinNow.Waitfortheprocesstocompleteandforthestoragecontrollermoduletoreboot,which
cantakeafewminutes.Whencomplete,theTimeSettingspageappears.

Dell

Dell Internal Use Only Confidential

26

Time Settings Page

Qualification Units OnlyFebruary 14, 2014

UsetheTimeSettingspagetosetthesystemtimefortheSC4020.

1 Setthetimezone.
a FromtheRegiondropdownmenu,selectthegeographicalregioninwhichtheSC4020islocated.
b FromtheTimeZonedropdownmenu,selectthetimezoneinwhichtheSC4020islocated.
Note: ForlocationsintheUnitedStates,eitherselectUSastheregionandselectatimezone
name,orselectAmericaastheregionandselectacitywithinthesametimezone.
2 Setthesystemtimeusingoneofthefollowingmethods.

Toconfiguretimemanually,selectConfigureTimeManually,thenenterthedateandtime.

ToconfiguretimeusingaNetworkTimeProtocol(NTP)server,selectUseNTPTimeServer,then
enterthefullyqualifieddomainname(FQDN)orIPaddressofanNTPserver.
Note: Accuratetimesynchronizationiscriticalforreplications.DellCompellentrecommends
usingNTPtosetthesystemtime.Formoreinformation,see:support.ntp.org/bin/view/Support/
WebHome.

3 Whenthesystemtimehasbeenset,clickContinue.TheSystemSetuppageappears.

Dell

Dell Internal Use Only Confidential

27

System Setup Page

Qualification Units OnlyFebruary 14, 2014

UsetheSystemSetuppagetosetthesystemnameandmanagementIPaddressfortheSC4020.

1 IntheSystemNamefield,enteranamefortheSC4020.Thisistypicallytheserialnumberofstorage
controllermodule1.
2 IntheManagementIPAddress(IPv4)field,enterthemanagementIPaddressspecifiedinthepre
installationdocuments.
ThemanagementIPaddressisdistinctfromstoragecontrollermodule1andstoragecontrollermodule
2addresses.ItistheaddressthatmanagesanSC4020asawhole.Ifeitherstoragecontrollermodulefails,
themanagementIPaddressremainsvalid.

Dell

Dell Internal Use Only Confidential

28

3 IntheManagementIPAddress(IPv6)field,enterthemanagementIPaddressspecifiedinthepre
installationdocuments.

Qualification Units OnlyFebruary 14, 2014

4 ClickContinue.Thewizardpromptsyoutoenableordisablethereadandwritecache.

5 Selectorclearthecheckboxestoenableordisablereadandwritecache.
Note: Disablecacheonlyifnovolumeswilleverusecache.Ifcacheisleftenabledonthispage,
itcanbedisabledlaterforindividualvolumes.SeetheStorageCenterSystemManager
AdministratorsGuideforinformationondisablingcacheonavolumebyvolumebasis.
6 ClickContinue.TheConfigureSMTPpageappears.

Dell

Dell Internal Use Only Confidential

29

Configure SMTP Page

Qualification Units OnlyFebruary 14, 2014

UsetheConfigureSMTPpagetoconfiguretheSMTPmailserverandthesenderemailaddress.This
configurationenablesalertmessageemailstobesenttouserswhohavespecifiedarecipientaddressintheir
contactproperties.

1 IntheSMTPMailServerfield,entertheIPaddressorfullyqualifieddomainnameoftheSMTPemail
server.ClickTestservertoverifyconnectivitytotheSMTPserver.
2 IntheSenderEmailAddressfield,entertheemailaddressofthesender.Thisaddressisrequiredby
mostSMTPserversandisusedastheMAILFROMaddressofemailmessages.
3 (Optional)ClickAdvancedtoconfigureadditionalSMTPsettingsforsitesthatuseanadvancedSMTP
configuration.Thepageforadvancedoptionsappears.

Dell

Dell Internal Use Only Confidential

30

Qualification Units OnlyFebruary 14, 2014

a VerifythattheEnableSMTPEmailcheckboxisselected.
b IntheSMTPMailServerfield,verifytheIPaddressorfullyqualifieddomainnameoftheSMTP
mailserverthatyouenteredinStep 1onpage 30.Modifythisfieldifnecessary.
c

IntheBackupSMTPMailServerfield,entertheIPaddressorfullyqualifieddomainnameofthe
backupSMTPmailserver.

d ClickTestservertotesttheconnection.
e IntheSenderEmailAddress(MAILFROM)field,verifytheemailaddressofthesenderthatyou
enteredinStep 2onpage 30.Modifythisfieldifnecessary.
f

IntheCommonSubjectLinefield,enteracommonsubjectlineforallemailsfromSC4020.

g (Optional)SelectSendExtendedHello(EHLO)toconfigureuseofextendedhelloformailsystem
compatibility.
InsteadofbeginningthesessionwiththeHELOcommand,thereceivinghostissuestheHELO
command.Ifthesendinghostacceptsthiscommand,thereceivinghostthensendsitalistofSMTP
extensionsitunderstands,andthesendinghostthenknowswhichSMTPextensionsitcanuseto
communicatewiththereceivinghost.ImplementingExtendedSMTP(ESMTP)requiresno
modificationoftheSMTPconfigurationforeithertheclientorthemailserver.
h (Optional)SelectUseAuthorizedLogin(AUTHLOGIN)andentertheLoginIDandPasswordif
theemailsystemrequirestheuseofanauthorizedlogin.
4 ClickContinue.TheUpdateSetuppageappears.

Dell

Dell Internal Use Only Confidential

31

Update Setup Page

Qualification Units OnlyFebruary 14, 2014

UsetheUpdateSetuppagetoconfigurehowSC4020handlessoftwareupdates.

1 Selectanupdateoptionfromthedropdownmenu:

Donotautomaticallycheckforsoftwareupdates:Selectthisoptiontodisableautomaticchecking
forupdates.Ifthisoptionisselected,thefollowingwillstillbeavailable:

ManuallycheckforupdatesbyselectingStorageManagementSystemUpdateCheckfor
UpdateasdescribedintheSC4020SystemManagerAdministratorsGuide.

ChangeupdateoptionsbyselectingStorageManagementSystemUpdateConfigure
AutomaticUpdatesasdescribedintheSC4020SystemManagerAdministratorsGuide.

Notifymeofasoftwareupdatebutdonotdownloadautomatically:Selectthisoptionto
automaticallycheckforupdatesandreceivenotificationwhenanupdateisavailable.Updatesare
notdownloadeduntilyouexplicitlydownloadtheupdate.(Thisisthedefaultsetting.)

Downloadsoftwareupdatesautomaticallyandnotifyme:Selectthisoptiontoautomatically
downloadupdatesandreceivenotificationwhenthedownloadiscomplete.

Nevercheckforsoftwareupdates(PhoneHomenotavailable):Selectthisoptiontopreventthe
systemfromevercheckingforupdates.ThisoptionisforsecuresitesatwhichPhoneHomeisnot
available.

2 ClickContinue.TheUserSetuppageappears.

Dell

Dell Internal Use Only Confidential

32

User Setup Page

Qualification Units OnlyFebruary 14, 2014

UsetheUserSetuppagetothesessiontimeoutandemailaddressesfortheAdminaccount.

3 FromtheSessionTimeoutdropdownlist,selectthesessiontimeout.
4 IntheEmail,Email2,andEmail3fields,enteremailaddressestowhichtheStorageCenterwillsend
systemalerts.
5 (Optional)ClickSendtestemailtomakesurethattheemailaddressesareaccurate.
Note: Makesurethetestemailisreceivedbyanadministrator.StorageCenterusesemailtosend
systemalerts.
6 ClickContinue.

Dell

Dell Internal Use Only Confidential

33

Configure IO Cards Page


UsetheConfigureIOCardspagetoconfigurenetworkattributesfortheiSCSIports.

Qualification Units OnlyFebruary 14, 2014

The10GbEthernetiSCSIportsoneachstoragecontrollermoduleareonlyusedforreplicationtoanother
StorageCenter.TheiSCSIportsshouldnotbeusedforfrontendconnectivitytoservers.

1 (Optional)ClickSkipiSCSIIOCardConfigurationtoconfigurenetworksettingsfortheiSCSIports
atalatertime.TheConfigurePortspageappears.
Note: DellCompellentrecommendsthatyouconfiguretheiSCSIportsduringsetup.
2 CompletetheIPAddress,aSubnetMask,andaGatewayfields.
3 ClickContinue.

Ifnomessagesaregenerated,theiSCSIportconfigurationissavedandtheConfigurePortspage
appears.

Ifthereisanissue,amessageappears.

Dell

ClickNotogobackandcorrecttheIPAddress,SubnetMask,and/orGatewayaddressforthe
iSCSIportsthatgeneratederrorsand/orwarnings.

ClickYestoignorethemessageandcontinue.TheConfigurePortspageappears.

Dell Internal Use Only Confidential

34

Configure Ports Page


UsetheConfigurePortspagetoconfigurethefrontendandbackendports.

Qualification Units OnlyFebruary 14, 2014

Select the Front-End Connectivity Mode


SelectthefrontendconnectivitymodefortheFibreChanneltransporttype.Ifvirtualportmodeislicensed,
thetransporttypescanbeconfiguredtousedifferentmodes.Ifvirtualportmodeisnotlicensed,all
transporttypesmustuselegacymode.
If

Then

VirtualPortsisNotLicensed

AlltransporttypesuseLegacyMode.Inthiscase,theStartupWizard
displaystheInitialPortConfigurationpage.Tocontinue,gotoConfigure
PortsWhenVirtualPortModeIsNotLicensedonpage 35.

VirtualPortsisLicensed

TheFCtransporttypecanuselegacymodeorvirtualportmode.Inthiscase,
theStartupWizarddisplaysanoperationalmodechoicepagethatallowsfor
thechoicebetweenmodesforeachsupportedtransporttype.Tocontinue,go
toConfigurePortsWhenVirtualPortModeIsLicensedonpage 37.

Note: ToskipportinitializationorifthereisnoFCswitchsetup,clickSkipPortInitialization.

Configure Ports When Virtual Port Mode Is Not Licensed


IfVirtualPortsisnotlicensed,thewizardinformsyouthatthelocalportshavenotbeenconfigured.

1 ClickContinuetogeneratetheinitialportconfiguration.
Whiletheinitialportconfigurationisbeinggenerated,theStartupWizarddisplaysapageshowing
progress.Aftertheconfigurationhasbeengenerated,itisautomaticallyvalidated.

Ifthevalidationissuccessful,aconfirmationpageappearsstatingthattheportconfigurationhas
beengenerated.

Ifthevalidationfails,apagedisplayingwarningsappears.

Dell

Dell Internal Use Only Confidential

35

Qualification Units OnlyFebruary 14, 2014

2 ClickConfigureLocalPorts.ThewizarddisplaysatabforeachtypeofIOcardthatisinstalledinthe
StorageCenter.

3 ConfigurethePurpose,FaultDomain,andUserAliasforalltransporttypes.SeeConfigureLocalPorts
onpage 40.
4 Whenyouarefinishedconfiguringthelocalports,clickAssignNow.Thewizardinformsyouthatthe
portconfigurationhasbeengenerated.

Dell

Dell Internal Use Only Confidential

36

Qualification Units OnlyFebruary 14, 2014

5 ClickContinue.TheGenerateSSLCertpageappears.

Configure Ports When Virtual Port Mode Is Licensed


IfVirtualPortsislicensed,thewizardinformspromptsyoutochoosethefrontendconnectivitymodefor
theFibreChanneltransporttype.

1 Selectthefrontendconnectivitymode.
a SelecttheoperationalmodefortheFCtransporttype.
b ClickContinuetoconfiguretheselectedoperationalmode.Thewizardinformsyouthatthe
operationalmodeshavebeenconfigured.

Dell

Dell Internal Use Only Confidential

37

Qualification Units OnlyFebruary 14, 2014

ClickContinuetobeginportinitializationintheselectedoperationalmode.
Thewizardverifiestheconfiguration,convertsselectedtransportstotheselectedmode,displays
progresspages,andpresentsaconfirmationpagewhenoperationalmodesfortransporttypeshave
beenconfiguredandinitialized.

Dell

Dell Internal Use Only Confidential

38

Qualification Units OnlyFebruary 14, 2014

d ClickConfigureLocalPorts.ThewizarddisplaysatabforeachtypeofIOcardthatisinstalledin
theStorageCenter.

2 ConfigurethePurpose,FaultDomain,andUserAliasforalltransporttypes.SeeConfigureLocalPorts
onpage 40.
3 Whenyouarefinishedconfiguringthelocalports,clickAssignNow.Thewizardinformsyouthatthe
portconfigurationhasbeengenerated.

4 ClickContinue.TheGenerateSSLCertpageappears.

Dell

Dell Internal Use Only Confidential

39

Configure Local Ports

Qualification Units OnlyFebruary 14, 2014

ConfigurethePurpose,FaultDomain,andUserAliasforalltransporttypes.Validportpurposesfor
transporttypesdependonwhethervirtualportsmodeislicensedonSC4020.

ConfigureFCPortsLegacyModeonpage 41

ConfigureFCPortsVirtualPortModeonpage 42

ConfigureSASPortsonpage 43

Thefollowingtableshowstheportpurposesforeachtransporttype.
Port Purpose

Transport Type

Description

FCandSAS

Oneofthefollowing:

Legacy Mode
Unknown

Portpurposeisnotyetdefined.
Theportisunused.
(SASandFConly)Theportisusedfordirectconnect
interprocesscommunication(IPC).
FrontEndPrimary

FC

PortisconnectedtoserversandisusedfortheserverIOpath.

FrontEndReserved

FC

Portisconnectedtoserversandusedasafailoverpath.Only
usedfordualcontrollerStorageCenters.

BackEnd

FCandSAS

Portisconnectedtodiskenclosures.

DirectConnect

FC

Thisportpurposeisnotused.Donotselectitforanyports.

FCandSAS

Oneofthefollowing:

Virtual Port Mode


Unknown

Portpurposeisnotyetdefined.
Theportisunused.
(SASandFConly)Theportisusedfordirectconnect
interprocesscommunication(IPC).
FrontEnd

FC

PortisconnectedtoserversandisusedfortheserverIOpath.

BackEnd

FC

Portisconnectedtodiskenclosures.

Dell

Dell Internal Use Only Confidential

40

Configure FC Ports Legacy Mode


UsetheFCtabtoconfiguretheFibreChannelportsinlegacymode.

Qualification Units OnlyFebruary 14, 2014

1 ClicktheFCtab.

2 CreateafaultdomainforeachpairofredundantFCports.
a ClickEditFaultDomains.Thewizarddisplaysalistofthecurrentlydefinedfaultdomains.
b ClickCreateFaultDomain.Adialogboxappears.
c

IntheNamefield,typeanameforthefaultdomain.

d FromtheTypedropdownmenu,selectFC.
e (Optional)IntheNotesfield,typeadescriptionofthefaultdomain.
f

ClickContinue.Thedialogboxdisplaysasummary.

g ClickCreateNowtocreatethefaultdomain.
h Repeatstepsbgasneededtocreateadditionalfaultdomains.
i

Whenyouarefinishedcreatingfaultdomains,clickReturn.TheFCtabappears.

3 ConfigureeachbackendFCport.
a SetthePurposefieldtoBackEnd.
b ConfirmthattheFaultDomainfieldissetto<none>.
c

(Optional)TypeadescriptivenameintheUserAliasfield.

4 ConfigureeachfrontendFCport.
a SetthePurposefieldtoFrontEndPrimaryorFrontEndReservedasappropriate.
b SettheFaultDomainfieldtotheappropriatefaultdomainthatyoucreated.
c

(Optional)TypeadescriptivenameintheUserAliasfield.

5 ConfigureeachportthatisunusedorusedforIPCbetweenstoragecontrollermodules.
a SetthePurposefieldtoUnknown.
b ConfirmthattheFaultDomainfieldissetto<none>.
c

Dell

(Optional)TypeadescriptivenameintheUserAliasfield.

Dell Internal Use Only Confidential

41

Configure FC Ports Virtual Port Mode


UsetheFCtabtoconfiguretheFibreChannelportsinvirtualportmode.

Qualification Units OnlyFebruary 14, 2014

1 ClicktheFCtab.

2 CreateafaultdomainforeachFCfabric.
a ClickEditFaultDomains.Thewizarddisplaysalistofthecurrentlydefinedfaultdomains.
b ClickCreateFaultDomain.Adialogboxappears.
c

IntheNamefield,typeanameforthefaultdomain.

d FromtheTypedropdownmenu,selectFC.
e (Optional)IntheNotesfield,typeadescriptionofthefaultdomain.
f

ClickContinue.Thedialogboxdisplaysasummary.

g ClickCreateNowtocreatethefaultdomain.
h Repeatstepsbgasneededtocreateadditionalfaultdomains.
i

Whenyouarefinishedcreatingfaultdomains,clickReturn.TheFCtabappears.

3 ConfigureeachbackendFCport.
a SetthePurposefieldtoBackEnd.
b ConfirmthattheFaultDomainfieldissetto<none>.
c

(Optional)TypeadescriptivenameintheUserAliasfield.

4 ConfigureeachfrontendFCport.
a SetthePurposefieldtoFrontEnd.
b SettheFaultDomainfieldtotheappropriatefaultdomainthatyoucreated.
c

(Optional)TypeadescriptivenameintheUserAliasfield.

5 (Optional)Changethepreferredphysicalportforoneormorevirtualports.
a ClickEditVirtualPorts.Thewizarddisplaysalistofvirtualports.
b Foreachvirtualportthatyouwanttomodify,selectthepreferredphysicalportInthePreferred
PhysicalPort.

Dell

Dell Internal Use Only Confidential

42

Whenyouarefinished,clickApplyChanges.

6 ConfigureeachportthatisunusedorusedforIPCbetweenstoragecontrollermodules.
a SetthePurposefieldtoUnknown.
b ConfirmthattheFaultDomainfieldissetto<none>.

Qualification Units OnlyFebruary 14, 2014

(Optional)TypeadescriptivenameintheUserAliasfield.

Configure SAS Ports


ConfigurethebackendSASports.
1 ClicktheSAStab.

2 ConfigureeachbackendSASport.
a SetthePurposefieldtoBackEnd.
b ConfirmthattheFaultDomainfieldissetto<none>.
c

(Optional)TypeadescriptivenameintheUserAliasfield.

3 ConfigureeachportthatisunusedorusedforIPCbetweenstoragecontrollermodules.
a SetthePurposefieldtoUnknown.
b ConfirmthattheFaultDomainfieldissetto<none>.
c

Dell

(Optional)TypeadescriptivenameintheUserAliasfield.

Dell Internal Use Only Confidential

43

Generate SSL Cert Page

Qualification Units OnlyFebruary 14, 2014

UsetheGenerateSSLCertpagetogenerateanewSecureSocketLayer(SSL)certificateorimportanexisting
certificatefortheSC4020.TheSSLcertificatemustmatchtheSC4020sIPAddressorDNShostname.
TheinitialcertificateshippedwiththeSC4020maynotmatchtheIPaddressorDNShostnameassignedto
theSC4020.Ifthisisthecase,whenconnectingtoSC4020,amessageisdisplayedidentifyingamismatch
betweenthecertificateandtheIPaddressorDNShostnameoftheSC4020.Importorgenerateacertificate
tocorrectthis.
Caution: DonotclickSkiptobypassthispage.ClickingSkipcanresultinconnectiondisruptions
toStorageCenterSystemManager.

Dell

Dell Internal Use Only Confidential

44

Import a Certificate
IfanSSLcertificatehasalreadybeengenerated,importthecertificate.

Prerequisites
Thepublickeyfilemustbeinx.509format.

Qualification Units OnlyFebruary 14, 2014

Steps
1 ClickImport.Afilebrowserappears.

2 Browsetothelocationofthepublickey(*.pem)fileandselectit.
3 ClickNext.
4 Browsetothelocationoftheprivatekeyfile(*.pem).
5 ClickNext.ASummarypageappearsthatidentifiesthekeyfilesselected.
6 ClickSavetoimportthecertificates.

Dell

Dell Internal Use Only Confidential

45

Create a New Certificate


IfyoudonotalreadyhaveacertificatethatcontainstheStorageCenterhostnameorIPaddress,generate
onenow.

Qualification Units OnlyFebruary 14, 2014

1 ClickGenerate.ThewizardpromptsyoutoentertheIPaddressesandhostnamesfortheStorage
Center.

2 Inthetextfield,enterallDNShostnames,IPv4addresses,andIPv6addressesforthisSC4020,separated
bycommas.Thewizardprepopulatesthefieldwithinformationitknows,butitislikelythatmoresite
specifichostnamesandaddressesneedtobeentered.
Caution: ThehostnamesandaddressesmustmatchthisStorageCenteroryouwillnotbeable
toreconnecttoit.
3 ClickGenerateNow.Anewcertificateisgeneratedandthesessionends.Tocontinue,refreshthe
browserandlogontotheSC4020again.

Perform Post-Setup Tasks


Performconnectivityandfailoverteststomakesurethatthedeploymentwassuccessful,thenchange
administrativepasswords,PhoneHome,andcheckforupdates.

Verifying Connectivity and Failover


ThissectiondescribesthegeneralstepsneededtoverifythatStorageCenterissetupproperlyandwill
failovercorrectly.Theprocessincludesconnectingaserverandcopyingdatatoverifyconnectivity,and
shuttingdownastoragecontrollermoduletoverifyfailoverandMPIOfunctionality.Fordetailsabouteach
step,refertotheStorageCenterSystemManagerAdministratorsGuide.

Dell

Dell Internal Use Only Confidential

46

Create Test Volumes


ConnectaservertotheStorageCenter,createoneormoretestvolumes,andmapthemtotheserverto
prepareforconnectivityandfailovertesting.
1 ConnectaservertotheStorageCenterusingFibreChannel.
2 StartawebbrowseronacomputerontheStorageCentermanagementnetwork.

Qualification Units OnlyFebruary 14, 2014

3 LogintoStorageCenterSystemManager.
4 DefinetheserverinSystemManager.
a IntheSystemTree,selectServers.
b ClickCreateServer.TheCreateServerwizardappears.
c

SelecttheserverHBAsinthetable,thenclickContinue.

d IntheNamefield,typeanamefortheserver.
e FromtheOperatingSystemdropdownmenu,selecttheoperatingsystemthattheserverisrunning.
f

ClickContinue.Thewizarddisplaysasummary.

g ClickCreateNow.Thewizarddisplaysalistofoptionalactions.
h ClickClose.Thewizardcloses.
5 Createa25GBtestvolumecalledTestVol1.
a IntheSystemTree,selectVolumes.
a IntheCreateServerwizard,clickCreateVolume.TheCreateVolumewizardappears.
b Setthevolumesizeto25GB,thenclickContinue.
c

ClickContinuetoapplythedefaultReplayProfile.

d TypeTestVol1intheNamefield,thenclickContinue.Thewizarddisplaysasummary.
e ClickCreateNow.Thewizarddisplaysalistofoptionalactions.
f

ClickClose.

6 RepeatStep 5tocreateasecondtestvolumenamedTestVol2.
7 MapTestVol1tostoragecontrollermodule1.
a IntheSystemTree,expandtheVolumesnode.
b SelectTestVol1.
c

ClickMapVolumetoServer.TheMapVolumetoServerwizardappears.

d Selecttheserver,thenclickContinue.Thewizarddisplaysasummary.
e ClickAdvanced.Thewizarddisplaysadvancedmappingoptions.
f

IntheRestrictMappingPathsarea,selecttheMaptocontrollercheckbox,thenselectthestorage
controllermodulefromthedropdownmenu.

g ClickContinue.Thewizarddisplaysasummary.
h ClickCreateNow.Themappingiscreatedandthewizardcloses.
8 RepeatStep 7tomapTestVol2tostoragecontrollermodule2.
9 Ontheserver,partitionandformatthetestvolumes.

Test Connectivity and Failover


Copydatatothetestvolumeandsimulatefailurestotestconnectivityandfailover.

Test Basic Connectivity


Verifyconnectivitybycopyingsomedatatothetestvolumes.

Dell

Dell Internal Use Only Confidential

47

Test Storage Controller Module Failover


PerformatesttomakesurethatIOisnotinterruptedbyastoragecontrollermodulefailover.
1 CreateaTestfolderontheserverandcopyatleast2GBofdataintoit.
2 Manuallyshutdownstoragecontrollermodule1whilecopyingdatatoTestVol1toverifythatIOisnot
interruptedbythefailoverevent.

Qualification Units OnlyFebruary 14, 2014

a CopytheTestfoldertotheTestVol1volume.
b Duringthecopyprocess,shutdownstoragecontrollermodule1(thestoragecontrollermodule
throughwhichthevolumeismapped).
c

Verifythatthecopyprocesscontinuesafterthestoragecontrollermoduleisshutdown.

d Afterthecopyfinishes,turnonthestoragecontrollermodule.
e Wait3minutesandverifythatthestoragecontrollermodulehasfinishedstarting.
f

Rebalancetheports.

3 Manuallyshutdownstoragecontrollermodule2whilecopyingdatatoTestVol2toverifythatIOisnot
interruptedbythefailoverevent.
a CopytheTestfoldertotheTestVol2volume.
b Duringthecopyprocess,shutdownstoragecontrollermodule2(thestoragecontrollermodule
throughwhichthevolumeismapped).
c

Verifythatthecopyprocesscontinuesafterthestoragecontrollermoduleisshutdown.

d Afterthecopyfinishes,turnonthestoragecontrollermodule.
e Wait3minutesandverifythatthestoragecontrollermodulehasfinishedstarting.
f

Rebalancetheports.

Test MPIO
IfthenetworkenvironmentandserversareconfiguredforMPIO,performteststomakesurethatfailed
pathsdonotinterruptIO.
1 CreateaTestfolderontheserverandcopyatleast2GBofdataintoit.
2 MakesurethattheFCserverisconfiguredtouseloadbalancingMPIO(roundrobin).
3 ManuallydisconnectapathwhilecopyingdatatoTestVol1toverifythatMPIOisfunctioningcorrectly.
a CopytheTestfoldertotheTestVol1volume.
b Duringthecopyprocess,disconnectoneofthepathsandverifythatthecopyprocesscontinues.
c

Reconnecttheport.

4 RepeatStep 3asnecessarytotestadditionalpaths.
5 RestartthestoragecontrollermodulethatcontainstheactivepathwhileIOisbeingtransferred.
6 IftheStorageCenterisnotinaproductionenvironment,restarttheswitchthatcontainstheactivepath
whileIOisbeingtransferred.

Clean up Test Volumes


Aftertestingiscomplete,deletethevolumesusedfortesting.

Dell

Dell Internal Use Only Confidential

48

Change Administrative Passwords


StorageCentershipswithdefaultadministrativecredentials.Asasecuritymeasure,changethe
administrativepasswordbeforeputtingtheStorageCenterintoproduction.
1 FromtheStorageManagementmenu,selectUserChangeUserPassword.

Qualification Units OnlyFebruary 14, 2014

2 SelectAdminandclickContinue.

3 EnteranewpasswordintheEnterPasswordandReenterPasswordfields.
4 ClickOK.

Configure a Phone Home Proxy


Ifrequireshoststouseaproxyservertoreachtheinternet,configurePhoneHometousetheproxyserver
beforesendingdatawithPhoneHomeorcheckingforSC4020updates.
1 FromtheStorageManagementmenu,selectSystemPhoneHomeConfigurePhoneHomeProxy.
TheConfigurePhoneHomeProxywizardstarts.

2 SelectUsePhoneHomeProxyServerandenterthefollowing:

ProxyServerAddress:EntertheIPaddressoftheproxyserver.

Port:EntertheTCPportnumberoftheproxyserver.

ProxyUserName:Entertheusernamefortheproxyserver.

ProxyPassword/ConfirmPassword:Passwordfortheproxyserver.

3 ClickOK.

Dell

Dell Internal Use Only Confidential

49

Phone Home
CompletesetupbysendingSC4020configurationinformationtoDellTechnicalSupportServiceswith
PhoneHome.

Qualification Units OnlyFebruary 14, 2014

PhoneHomesendsacopyofaSC4020configurationtoDellTechnicalSupportServicestoenablethemto
supportaSC4020.TheinitialconfigurationissenttoDellTechnicalSupportServiceswhenSC4020is
installed.

Prerequisites

TCPports22and443mustbeallowedoutboundtotheInternet.

IfthenetworkrequireshoststouseaproxyservertoreachtheInternet,theStorageCentermustbe
configuredtouseaPhoneHomeproxy.

Steps
1 FromtheStorageManagementmenu,selectSystemPhoneHomePhoneHome.ThePhone
Homewizardstarts,listinganypreviousPhoneHomeevents.

2 ClickPhoneHomeNow.ThePhoneHomeInProgressdialogboxisdisplayed.
3 ClickOK.
4 WhentheStatecolumnlistsallitemswithSuccess,clickClose.

Dell

Dell Internal Use Only Confidential

50

Check for Storage Center Updates


AftercompletingtheSC4020setup,iftheStorageCenterSystemManagerdidnotdisplayamessageof
availableupdates,manuallycheckforavailableStorageCenterupdates.
1 FromtheStorageManagementmenu,selectSystemUpdateUpdateStatus.

Qualification Units OnlyFebruary 14, 2014

2 ClickCheckNow.AsStorageCenterchecksforupdates,statusappearsontheUpdateStatuspage.
3 Ifanupdateisavailable,installtheupdatefollowingtheinstructionsintheStorageCenterSystemUpgrade
Guide.

Next Steps
Afterinstallationiscomplete,youmightwanttoperformsomebasictaskstoconfigureStorageCenterfor
yourenvironment.Thesetasksareconfigurationdependentsosomemightnotapplytoyoursite.
SeetheStorageCenterAdministratorsGuidefordetailedconfigurationinstructions,includinghowto:

SetstoragecontrollermoduleandsystemIPaddressesforIPv6(ThismustbedoneifusingIPv6
addressing)

Manageunmanageddisks

AddStorageCenterusers;includingconfiguringLightweightDirectoryAccessProtocol(LDAP)

Configurepasswordrulesforlocalusers.

Createservers

ConfigureUserVolumeDefaults

AddStorageCentervolumes

Addaloginmessage

Troubleshooting
Thisappendixcontainstroubleshootingstepsforcommonproblems.

Troubleshooting the Serial Connection


Issue

Possible Reason

Unabletoconnecttoastorage Communicationproblems.
controllermodulewitha
serialconnection

Solution
Reseatorreplacecables.
Verifythetelnetsettings.

Troubleshooting Storage System Enclosures


Issue

Possible Reason

NoDisksFoundbyStartup
Wizard:

Needtoupdatesoftwareand/or 1 ClickQuit.
firmwaretousedrives
2 CheckforStorageCenterUpdatesonpage 51

Nodiskscouldbefound
attachedtothisDell
CompellentStorageCenter.
ExpectedDisksareMissing

Dell

Solution

3 CompletetheStartupWizardonpage 19.

Needtoupdatesoftwareand/or 1 CheckdriveLEDs.
firmwaretousedrives.
2 CheckforStorageCenterUpdatesonpage 51.

Dell Internal Use Only Confidential

51

Qualification Units OnlyFebruary 14, 2014

Troubleshooting Licenses
Issue

Possible Reason

Solution

Error:Thelicensefileisnot
valid(couldbeoldlicense
file).ContactDellTechnical
SupportServicesforanew
licensefile.

Canhappenwithadual
controllerStorageCenterif
thereisanattempttoapplythe
licensefilebeforethestorage
controllermodulesarejoined
andthelicensefileisappliedto
thestoragecontrollermodule
withthewrongserialnumber.

MakesurethatallthestepsinSetUpSoftware
CenterSoftwareonpage 12arefollowedinorder
andtryagain.
MakesuretoconnecttotheIPaddressofthe
storagecontrollermodulewiththelowerserial
number.
Makesuretheserialnumberinthenameofthe
licensefilematchesthestoragecontroller
module.

Troubleshooting Updates
Issue

Possible Reason

Solution

CannotcompleteStartup
Yournetworkmightemploya 1 EstablishaserialconnectiontotheStorage
Wizardandcannotcheckfor proxyserver,ConfigurePhone
Center.
updates
HomeProxyServerUsingthe 2 Runthefollowingcommands:
CommandLineInterface(CLI).
mc values set UsePhHomeProxy true
mc values set PhHomeProxyString
[proxy server IP address]
mc values set PhHomeProxyUserName
[proxy server user name]
mc values set PhPomeProxyPassword
[proxy server password]
3 CheckforStorageCenterUpdatesonpage 51.
4 CompletetheStartupWizardonpage 19.

Dell

Dell Internal Use Only Confidential

52