Vous êtes sur la page 1sur 2

Units system: Metric

Preliminary Reinforced Concrete Design


Design code: ACI 318-2005

Design Results

___________________________________________________________________________________________________________________________________________________________________________
Load conditions
C1=1.4CM
C2=1.2CM+1.6CV
C3=1.2CM+CV+0.18EX+0.05EZ
C4=1.2CM+CV+0.18EX-0.05EZ
C5=1.2CM+CV-0.18EX+0.05EZ
C6=1.2CM+CV-0.18EX-0.05EZ
C7=1.2CM+CV+0.05EX+0.18EZ
C8=1.2CM+CV+0.05EX-0.18EZ
C9=1.2CM+CV-0.05EX+0.18EZ
C10=1.2CM+CV-0.05EX-0.18EZ
C11=0.9CM+0.18EX+0.05EZ
C12=0.9CM+0.18EX-0.05EZ
C13=0.9CM-0.18EX+0.05EZ
C14=0.9CM-0.18EX-0.05EZ
C15=0.9CM+0.05EX+0.18EZ
C16=0.9CM+0.05EX-0.18EZ
C17=0.9CM-0.05EX+0.18EZ
C18=0.9CM-0.05EX-0.18EZ
COLUMNS

COL
Faxial
M33
M22
Load
A.required
Length
V3
V2
Stirrup spacing
BxH
ID
ID
[Ton]
[Ton*m]
[Ton*m]
[cm2]
[m]
[Ton]
[Ton]
Bar
[cm]
[cm]
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------56
-23.95
-6.00
1.24
C4
12.00
3.40
0.74
3.42
#3
12.50
30x40
21
-25.53
-2.77
1.49
C9
12.00
3.40
0.92
1.47
#3
12.50
30x40
22
25.87
2.03
-0.40
C13
12.00
3.40
0.14
0.69
#3
12.50
30x40
23
-9.17
-3.95
0.80
C9
12.00
3.40
1.26
2.34
#3
12.50
30x40
24
-12.16
3.95
0.82
C7
12.00
3.40
1.24
2.21
#3
12.50
30x40
25
-17.12
-4.10
-1.97
C10
12.00
3.40
1.14
2.02
#3
12.50
30x40
26
-23.17
4.61
-2.09
C8
12.00
3.40
1.20
2.17
#3
12.50
30x40
27
-60.03
2.91
0.63
C6
12.00
3.40
0.37
1.37
#3
12.50
30x40
28
-40.11
-4.13
0.77
C4
12.00
3.40
0.44
2.17
#3
12.50
30x40
49
-15.55
4.66
-2.19
C9
12.00
3.40
1.29
2.68
#3
12.50
30x40
50
-4.96
-0.07
-1.57
C8
12.00
3.40
1.19
0.46
#3
12.50
30x40
51
-8.15
7.36
-0.28
C5
12.00
3.40
0.28
4.57
#3
12.50
30x40

Page1

52
-10.77
-6.96
-0.22
C3
12.00
3.40
0.27
4.37
#3
12.50
30x40
53
-12.39
6.18
2.73
C10
12.00
3.40
1.57
3.47
#3
12.50
30x40
54
-14.24
-6.86
2.99
C8
12.00
3.40
1.74
3.97
#3
12.50
30x40
55
-8.63
1.29
-1.75
C10
12.00
3.40
1.16
1.83
#3
12.50
30x40
77
-5.44
4.00
-0.88
C5
12.00
3.25
0.48
2.31
#3
12.50
30x40
78
-1.36
-0.13
-1.56
C8
12.00
3.25
1.09
0.29
#3
12.50
30x40
79
-2.27
4.76
-0.30
C5
12.00
3.25
0.38
2.83
#3
12.50
30x40
80
-0.10
-4.46
-0.20
C4
12.00
3.25
0.23
2.59
#3
12.50
30x40
81
-6.37
-6.49
-1.50
C6
12.00
3.25
0.84
3.79
#3
12.50
30x40
82
-3.58
-4.92
2.19
C8
12.00
3.25
1.40
2.59
#3
12.50
30x40
83
-8.28
-6.00
0.42
C5
12.00
3.25
0.06
2.38
#3
12.50
30x40
84
-6.46
4.69
-0.50
C4
12.00
3.25
0.37
2.73
#3
12.50
30x40
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------Notes.General information:
- Only selected members are shown.
- Deflection should be verified by user.
- Equivalent rectangular stress block is assumed for concrete beam and column design.
Beams:
- V3, M22 and axial forces are ignored in beam member design.
- Only rectangular and T sections are designed.
- Type: U= opened stirrup []= closed stirrup >[]<= has compression reinforcement.
- Left is J beam node. Right is K beam node.
- IP left (inflection point) is the distance from J node to inflection point.
- IP right (inflection point) is the distance from K node to inflection point.
- Stirrup spacing is given for: 0%-25%, 25%-75%, and 75%-100%
- M min/max are maximum and minimum bending moments found for this beam.
- Skin is required reinforcement to resist torsion. Half the area should lie at each vertical face.
Columns:
- Torsion is ignored.
- Only rectangular and circular sections are designed.
- Columns are verified at 2 stations: top and bottom ends.
- Sway magnifier factors for members due to bending moments are ignored.
- Analyze with P-Delta to consider slenderness in the design of columns.
Important:
- Required areas are calculated according to the section reinforcement distribution in database (LEO). Default sections in database have 5 reinforcement bars per side.

Page2