Vous êtes sur la page 1sur 2

represented by:

measurIT technologies

udløb

Centrifugal valve CE/V


wet mounted

Flexible solution
• A suitable CE/V controller can be found H
for any design flow between 0.2 l/s and [m]
80 l/s, please see diagram to the right.
• CE/V's fully adjustable inlet makes it
possible to set water flow within a range
of at least +/-20%.
• Delivered with changeable outlet nozzle.
Allows for further adjustment of flow. Q [l/s]

• Is delivered with coupling and


dismantling rod, which enables easy and Application chart
convenient mounting and de-mounting
from outside the manhole.
• CE/V can be used for storm water and
certain types of industrial waste water. inlet WL

H
inlet outlet
Effective control Q

• Ensures close to constant discharge, min.


350 mm
Qdes, virtually regardless of upstream
head, H. This is illustrated by the head-
discharge curve sketch to the right.
Definition sketch

MeasurIT Technologies Ltd.


Craan, Craanford, email: info@measurIT.com Phone: +353 (0) 53 942 8962
Gorey, Co. Wexford, Ireland www.measurIT.com Fax: +353 (0) 53 942 8963
represented by:

measurIT technologies

Low maintenance/operating
costs H
[m]
• Large passageway
(Qdes,Hdes)
• No moving parts
• Does not require any power supplies
• Fabricated in acid-resistant stainless steel
AISI 316L (Werkstoff 1.4404)

Q [l/s]
Low construction costs Head-discharge curve for CE/V
• Can be fitted in existing or designed
manholes or tanks - a separate housing
structure is mostly not required. CE/V

• However, a sump must be available.


• Inexpensive

Typical applications
• Roof-top runoff
• Temporary storage in upstream sewer
system
• At inlet to oil traps
• And many other situations

MeasurIT Technologies Ltd.


Craan, Craanford, email: info@measurIT.com Phone: +353 (0) 53 942 8962
Gorey, Co. Wexford, Ireland www.measurIT.com Fax: +353 (0) 53 942 8963