Académique Documents
Professionnel Documents
Culture Documents
9/22/2015
Version 5.6.0
Legal Notices
Legal Notices
The software described in this document is furnished under license, and may be used or copied only in accordance with
the terms of such license and with the inclusion of the copyright notice shown on this page. Neither the software, this
document, nor any copies thereof may be provided to, or otherwise made available to, anyone other than the licensee.
Title to, and ownership of, this software remains with Cognex Corporation or its licensor. Cognex Corporation assumes
no responsibility for the use or reliability of its software on equipment that is not supplied by Cognex Corporation.
Cognex Corporation makes no warranties, either express or implied, regarding the described software, its
merchantability, non-infringement or its fitness for any particular purpose.
The information in this document is subject to change without notice and should not be construed as a commitment by
Cognex Corporation. Cognex Corporation is not responsible for any errors that may be present in either this document or
the associated software.
Companies, names, and data used in examples herein are fictitious unless otherwise noted. No part of this document
may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, nor
transferred to any other media or language without the written permission of Cognex Corporation.
Copyright 2015. Cognex Corporation. All Rights Reserved.
Portions of the hardware and software provided by Cognex may be covered by one or more U.S. and foreign patents, as
well as pending U.S. and foreign patents listed on the Cognex web site at: http://www.cognex.com/patents.
The following are registered trademarks of Cognex Corporation:
Cognex, 2DMAX, Advantage, Alignplus, Assemblyplus, CheckitwithChecker, Checker, CognexVisionforIndustry,
CognexVSOC, CVL, DataMan, DisplayInspect, DVT, EasyBuilder, Hotbars, IDMax, In-Sight, LaserKiller, MVS-8000,
OmniView, PatFind, PatFlex, PatInspect, PatMax, PatQuick, SensorView, SmartView, SmartAdvisor, SmartLearn,
UltraLight, VisionSolutions, VisionPro, VisionView
The following are trademarks of Cognex Corporation:
The Cognex logo, 1DMax, 3D-Locate, 3DMax, BGAII, CheckPoint, CognexVSoC, CVC-1000, FFD, iLearn, In-Sight
(design insignia with cross-hairs), In-Sight2000, InspectEdge, Inspection Designer, MVS, NotchMax, OCRMax,
PatMaxRedLine, ProofRead, SmartSync, ProfilePlus, SmartDisplay, SmartSystem, SMD4, VisiFlex, Xpand
Other product and company trademarks identified herein are the trademarks of their respective owners.
Table of Contents
Table of Contents
Legal Notices
Table of Contents
Configuration Codes
Product Settings
Reset
Diagnostics
Setup
Light Aimer
10
Trigger Type
11
12
Custom Commands
13
Maximum Exposure
14
Symbology Settings
17
2D Symbology Settings
25
27
1D Symbology Settings
29
Training
31
32
Non-Printable Characters
34
Wireless
35
Buffering
36
Power Management
37
Wake-up Message
38
39
40
41
USB Connection
52
USB Mode
54
Communication Settings
56
60
62
Table of Contents
64
65
RS-232 Handshaking
66
RS-232 Routing
67
Network Settings
68
Decode Settings
69
Master / Slave
70
Keyboard Country
71
74
75
76
Configuration Codes
Configuration Codes
Configuration Codes are special Data Matrix codes to configure your reader without the DataMan Setup Tool. Lights and
beeping indicate that a Configuration Code was read. Beeps can also indicate that a command has not been executed: if
the code is read but the command is not executed (e.g. because of the command not being valid for the type of reader
used for reading the code), the reader gives 2 beeps.
You can read these codes without enabling the decoding of Data Matrix symbols. In such cases, make sure that you use
Manual or Presentation trigger mode.
Adjust focus settings if you have trouble reading Configuration Codes.
Note: When using wireless handheld readers, the reader must be put on the base station for security reasons after
reading a printed configuration code.
Product Settings
Product Settings
Reset Scanner to Factory Defaults
DM100
DM8000Base
Reset
Reset
Reboot Scanner
DM8000Base
Diagnostics
Diagnostics
Output Diagnostic String
(only with RS-232 and USB connections)
DM8000 wireless
Setup
Setup
Enable Setup 1 Only
Light Aimer
Light Aimer
*Light aimer ON
(default for DMAE50, DM50, DM60, DM100, DM200, and
DM8000)
10
Trigger Type
Trigger Type
Enable Presentation
11
DMAE50
DMAE50
12
Custom Commands
Custom Commands
Enable Serial Trigger
13
Maximum Exposure
Maximum Exposure
100 s
133 s
*170 s
250 s
500 s
14
Maximum Exposure
800 s
*1000 s
(default for DM50, DM60, DM300, DM360, and DM503)
2000 s
5000 s
8000 s
10000 s
15
Maximum Exposure
*13333 s
(default for DM8000)
20000 s
25000 s
16
Symbology Settings
Symbology Settings
*Enable ID Max
Enable ID Quick
Enable QR Code
17
Symbology Settings
*Disable QR Code
Enable MaxiCode
*Disable MaxiCode
18
Symbology Settings
Disable Code 128
*Enable UPC/EAN
Disable UPC/EAN
*Enable Code 39
Disable Code 39
*Enable Code 93
19
Symbology Settings
Disable Code 93
*Disable Interleaved 2 of 5
*Enable Codabar
Disable Codabar
Enable Pharmacode
20
Symbology Settings
*Disable Pharmacode
*Enable PDF417
(default for handheld readers)
*Disable Databar
21
Symbology Settings
*Disable Micro PDF417
Enable POSTNET
*Disable POSTNET
Enable PLANET
22
Symbology Settings
*Disable PLANET
Enable UPU
23
Symbology Settings
*Disable UPU
24
2D Symbology Settings
2D Symbology Settings
Enable Extreme Print Growth
(Data Matrix only)
25
2D Symbology Settings
*QR Symbol Difficulty - Easy
26
Version 9 (53x53)
27
28
1D Symbology Settings
1D Symbology Settings
*Enable Use Target Decoding
(simulates laser scanning)
(default for handheld readers except for DM8000)
29
1D Symbology Settings
Code Orientation: Ladder and Picket Fence
30
Training
Training
Enable incremental training
31
32
33
Non-Printable Characters
Non-Printable Characters
Enable Translate Unprintable Characters
34
Wireless
Wireless
Unassign Reader from Base Station
DM8000
DM8050, DM8600
35
Buffering
Buffering
*Enable Offline Buffering
DM8000 Wireless
DM8000 Wireless
36
Power Management
Power Management
Disable Hibernation Mode
37
Wake-up Message
Wake-up Message
Enable Output Diagnostic String on Wake-up
38
DM8000Base
DO NOT SCAN this code when you have an actual
keyboard connected.
DM8000Base
39
DM9050 DM9500
DM9050 DM9500
40
ENTER
main ENTER, not numeric keypad ENTER
DM50 DM60 DM700 DM8000 DM8000Base
ESCAPE
DM50 DM60 DM700 DM8000 DM8000Base
BACKSPACE
DM50 DM60 DM700 DM8000 DM8000Base
TAB
DM50 DM60 DM700 DM8000 DM8000Base
ALT+A
specifically the left ALT key
DM50 DM60 DM700 DM8000 DM8000Base
ALT+B
specifically the left ALT key
DM50 DM60 DM700 DM8000 DM8000Base
ALT+C
specifically the left ALT key
DM50 DM60 DM700 DM8000 DM8000Base
ALT+D
specifically the left ALT key
DM50 DM60 DM700 DM8000 DM8000Base
ALT+E
specifically the left ALT key
DM50 DM60 DM700 DM8000 DM8000Base
ALT+F
specifically the left ALT key
DM50 DM60 DM700 DM8000 DM8000Base
41
42
F1
DM50 DM60 DM700 DM8000 DM8000Base
43
F3
DM50 DM60 DM700 DM8000 DM8000Base
F4
DM50 DM60 DM700 DM8000 DM8000Base
F5
DM50 DM60 DM700 DM8000 DM8000Base
F6
DM50 DM60 DM700 DM8000 DM8000Base
F7
DM50 DM60 DM700 DM8000 DM8000Base
F8
DM50 DM60 DM700 DM8000 DM8000Base
F9
DM50 DM60 DM700 DM8000 DM8000Base
F10
DM50 DM60 DM700 DM8000 DM8000Base
HOME
DM50 DM60 DM700 DM8000 DM8000Base
ARROW UP
DM50 DM60 DM700 DM8000 DM8000Base
44
ARROW LEFT
DM50 DM60 DM700 DM8000 DM8000Base
ARROW RIGHT
DM50 DM60 DM700 DM8000 DM8000Base
END
DM50 DM60 DM700 DM8000 DM8000Base
ARROW DOWN
DM50 DM60 DM700 DM8000 DM8000Base
PAGE DOWN
DM50 DM60 DM700 DM8000 DM8000Base
INSERT
DM50 DM60 DM700 DM8000 DM8000Base
DELETE
DM50 DM60 DM700 DM8000 DM8000Base
GUI LEFT
DM50 DM60 DM700 DM8000 DM8000Base
GUI RIGHT
DM50 DM60 DM700 DM8000 DM8000Base
ALT+F1
specifically the left ALT key
DM50 DM60 DM700 DM8000 DM8000Base
45
F12
DM50 DM60 DM700 DM8000 DM8000Base
46
47
48
49
50
51
USB Connection
USB Connection
*USB-COM/RS-232
USB Keyboard
DM8000Base
*Disable USB Keyboard for the base station
Reboot needed after disabling USB keyboard for the base
station!
DM8000Base
Enable Enumerate in HID mode only
Reboot needed for changing between HID and USB mode
of base/reader!
DM8000Base
52
USB Connection
Disable Enumerate in HID mode only
Reboot needed for changing between HID and USB mode
of base/reader!
DM8000Base
*Enable Base USB
Reader switches to USB when in the base.
DM8000Base
DM8000Base
53
USB Mode
USB Mode
USB compatibility mode enabled
DM8000Base
DM8000Base
DM8000
54
USB Mode
*USB 1.1 mode
DM8000
DM8000Base
DM8000Base
55
Communication Settings
Communication Settings
*Enable DHCP
(default for all Ethernet readers)
Enable EtherNet/IP
Enable EtherNet/IP
56
Communication Settings
*Disable EtherNet/IP
*Disable EtherNet/IP
Enable PROFINET
Enable PROFINET
*Disable PROFINET
*Disable PROFINET
57
Communication Settings
Enable SLMP Protocol
58
Communication Settings
*Disable Modbus TCP
59
9600 BPS
19200 BPS
19200 BPS
38400 BPS
60
*57600 BPS
(default for DMAE50, DM300, DM360 and DM8000)
*115200 BPS
(default for DM50, DM60, DM100, DM200, DM503, and
DM700)
61
All readers
None
Odd
All readers
Odd
Even
All readers
62
Mark
DM8050 DM8600
Mark
Space
DM8050 DM8600
Space
63
Databit 7
Databit 8
Databit 8
64
Stopbit 1
Stopbit 2
Stopbit 2
65
RS-232 Handshaking
RS-232 Handshaking
*RTS/CTS Off
RTS/CTS Off
RTS/CTS On
RTS/CTS On
66
RS-232 Routing
RS-232 Routing
*Route to associated reader
DM8000 (wireless)
DM8000 (wireless)
67
Network Settings
Network Settings
Enable Network Client
68
Decode Settings
Decode Settings
*Never Read the Same Code Twice Off
69
Master / Slave
Master / Slave
Enable MST
*Disable MST
70
Keyboard Country
Keyboard Country
*USA
*USA
Germany
Germany
France
71
Keyboard Country
France
Spain
Spain
Japan
Japan
Norway
72
Keyboard Country
Norway
Finland
Finland
73
74
100 ms ON
*0 ms OFF
DM8000Base
100 ms ON
DM8000Base
75
DM100
DM100
DM100
DM100
DM100
76
DM100
DM100
DM100
DM100
DM100
DM100
77
DM100
* - Default setting
78