1. The circulation tank is filled with water.

2. V5 is made sure in fully close position.


3. Main power supply is switched on
4. The main switch on the control panel is turned on. All digital indicators ensured to be
illuminated.
5. The following valve position is checked
Pump Operation

Running Pump

Fully Open Valve

Fully Close Valve

Series

Both Pump, P1 & P2

V1, V3

V2, V4

Parallel

Both Pump, P1 & P2

V1, V2, V4

V3

7. The pump turned on and V5 slowly opened until maximum flow rate is achieved.
Experiment procedures is followed to determine the desired flow rate.
8. Pump speed selector switch used to monitor the pump speed.
9. Pressure selector switch to monitor the pressure in the pipe.
10. The pump speed controller turned clockwise until pump speed increased or anti- clockwise to
decrease the pump speed.
5.2 General Shut-down Procedures
1. The pump is turned off
2. Valve V5 is made sure in fully close position.
3. Main switch on the control panel is turned off.
4. The computer is shut downed
5. Main power supply is switched off.

5.3 Experiment 1 Pumps in Series Operation


Equipment Set Up:

1.
2.
3.

Fully Close Valve

Fully Open Valve

Variable Parameter

Pump ON

V2 & V4

V1 & V3

V5

Both Pump

Procedures:
The basic procedure as written in section 4.1 is followed.
All setting ensured to follow the equipment set up.
Pump characteristics tested under the following conditions and the data is recorded.
i. Maximum motor speed; varied V5 opening
ii. V5 fully opened; varied motor speed

5.4 Experiment 2 - Pumps in Parallel Operation


Equipment Set Up:

1.
2.
3.

Fully Close Valve

Fully Open Valve

Variable Parameter

Pump ON

V3

V1, V2 & V4

V5

Both Pump

Procedures:
The basic procedure as written in section 4.1 is followed.
All setting ensured follows the equipment set up.
The pump characteristics tested under the following conditions and records the data.
i. Maximum motor speed; varied V5 opening
ii. V5 fully opened; varied motor speed
5.5 General Shut-down Procedures
1. The pump is turned off
2. Valve V5 is made sure in fully close position.
3. Main switch on the control panel is turned off.
4. The computer is shut downed
5. Main power supply is switched off.