Vous êtes sur la page 1sur 5
FOTEK Solid State Module 7 a a ry i 2 & In ‘sHow ‘39 DOMES CEC Y Rn lek} High Dielectric strength over 4KV With over heat protection Circuit (120°C ) High surge current sustenance High surge voltage sustenance HR EEE BENE MaKV ‘esA@iS 5H BM 1 OOMOVSOOVOC i RM ER GL RR PRM BAM ARE RA oft RE ee ER LE TE 4S EN60047-4-3 and EN6O9SORRAE HER ERE @ Gui 1g of model / BY5%S85] High Isolation strength over 100Ma/S00VDC. Conformity with EN60947-4-3 and EN60950 Raa Sai eae RM eS tae ate 1> Product / m= "SSR. = Single phase sold siete module HPR = High power sol state module TSR. ree phases solid stale module TESR, = Three phases High power sold state module EZR. lug type solid state module 2> Output current / SHB yit FOy=108 125, 225A “0. 50, =50A "60, =60A "80, = 804 3> net method / #A7ax¢ 4> Output voltage / Si 7BBE TA, =AC voltage "D4 = Devotage 5> Output voltage range / sit} m2 Hs = High vatage ype Non = Standard type 6> Control method / #2#/73z0 "Ry = Random control Non = Zero cross control ex SSR-P 03 DA-H 1 23 46 6 1> Product / aan ingle phase sod state module ingle phase linear solid state module 2 Mounting method or Others Ks = Heatsink ype TF) =Fuse ype 3> Output current / SiH Bt Foay=9a "10, = 108 255 =25A "40, = 404 4> Input method / #A7Ix¢ ~32v0C S> omen voltage / ath aE votage 1D = be wtege 6> Output voltage range / @H SSL) TH = High votage type "Won = Standard type @ Control method / ##)77zt Zero cross trigger method (Output will be turned ON or Tumed OFF only on the Zero point of sine wave, that may avoid to occur the EM or RFI. Specially suited to control the resistive, capacitive and non-saturated inductive load BABE EMO SL ae MA BIEL BAP] » Disease SeRAREMI / RFI > SRSA BAe Sattek eA Mt SAS ° Variable resistance control method (Trimmer control ) Power output is controlied by the Trigger angle of the Triac that is controlled with variable resistor (250KQI110VAC, 500K 2/220VAC, 1M2/220VAC ) LRM ISI TrinclRRAPR HEIN HTD © (250K Q/110VAC, 500KQ/220VAC, 1MQ/380VAC ) Application hints / FARA FOTEK State Module Output — aya 5 ——— bine ~ To protect the solid state module against a short-circuit ofthe load, please use a fuse with a Ft value < 1/2 Ft value specified SENRSAARIAAA (Pt value “HOREIEE—) LURE RR ANERSTERM ERI NEIRED © 2> The thermal conductive silicone rubber or thermal grease Is required When the solid state module is mounted on a heat sink ERMA LBM ABTS HORI (BARB (K) >4.51 © 3> The rated current is corresponding toa resistive load, ifthe solid state module is applied in other loads, Please consider the inrush current at turn on and the surge vottage at tum off. SAGARA CAL ATMA MAS ORE EAOAM ERS AMER - + Electric discharge lamps: Those loads have the "inrush current, atturn on and the ‘surge voltage s at turn off, please use high votage types on 220VAC mains ‘BFRELR (MEM) | ASSGCRAMIAAR 220VACHE RAMEY BALL,» + Incandescent lamp: The rated current of the module must be over 4 times ofthe incandescent lamp current. FAED (HIRE): RARE SMALRE RRA RR AME ER AG OH + Three phase motors: The rated current ofthe s module must be over 4 times ofthe three phase motor average current SHES ASREWE A SEMIS AAAS PSR ONE, « ‘ Transformer loads: The rated current of the module must be over 10 times of the transformer current BREAN: ASRRENT A GRR ERRAARMEARE RS (1H, « *% Capacitor loads, the rated current of the module must be over 3 times of the capacitor current RAGAN: ABSREMORA DELAOMERRAAMESEANRA =H,» Bi Notice of safety / 2232850 no Potentially hazardous situation, if mishandling, may result in death or serious injury. a EER» SRR HE OTA OLA IE © 1> Please do not touch any terminal ofthis module while power supply is supplied, if do, it may result in electronio shook ‘Roh » BODRUM CUA TARR F LESAN» 2> "Power supply system. must to be shutdown before renew the fuse, if nt, t may resutin eletronic shock BRAT + ASAIO RRA ° 3> Please rated the load current within the specified value, if not, it may result to bum up this madule or fuse. SURRSRETDABIOATE LHS RIA Aha IIR © 44> Please tighten the screw terminal over 100kg-cm, i not, it may resuit to bum up this module or fuse. SUDHA FARAK «HED IRABIB OOto-cm + HATER DAE RUMANIA 5> Ifthis module is burned up, it may be in short circuit condition or malfunction, Please settle an independent alarm ‘system to ensure safety protection, int, it may result in a serious accident. ADGA TTT - ARLES - GNARL TN » OTR rsd ° m 2 ry oH a PPR CP 29 FOTEK Pies Serene Mosel LongtnLwm) | _Carentawaton Poster SSR 8.50 500 5A max ‘Single HS-100 1000) 30Amax Twice 15-150 1500) Three 5.200 200.0 Four HS-250 250.0 == Five How to use Heat sink & Cooling Fan for ESR series / Sa HALia8 Ri A) BL IL < SAmps Non-required Nonrequired ik <10Amps HS-ESR-100 Non-required ie >10Amps HS-ESR-100 Required M=W+ (x8xVLx 058) I=W+ (x8xVLx 0058) ‘VL: Line voltage; cos®: Power factor = Model of Heat sink: HS-ESR-100 % Outline of cooling fan: 80mm x 0mm

Vous aimerez peut-être aussi