Measurement of liquid ammonium nitrate (NH4NO3), Measurement
80% – 97% at 140 °C – 190 °C, in pipes of diameter DN 80 – 150 .

Instruments Used Customer


®
4 FLUXUS ADM 7207 with transducers Q3E or M2E
Advantages
• Accurate non-intrusive measurement
• No plant shut-down for installation
• No shortening of lifetime due to liquid temperature
• Cost effective reconstruction of plant
Selling Points
• No meter damages due to temperature shift or mechanical tension DSM Agro, Ijmuiden, NL
• No meter damages through product solidification at ambient DSM Agro is a subsidiary of the
temperature global operating DSM group. At its
site in Ijmuiden (NL), it manu-
factures fertilizers. The DSM Agro
facilities in Ijmuiden and Geleen
produce together 1.6 million tons
Description of fertilizers yearly.

Ammonium nitrate (NH4NO3) is used as nitrogen supplying fertilizer in the


agricultural industry. It is solid under ambient conditions. Upon dilution with
water, it dissociates in positive ammonia ions and negative nitrate ions that
can directly be absorbed by the plants.
Until now, DSM Agro has been using magnetic flowmeters with ceramic
liners for process control within the fertilizer production. During the
measurement of the liquid ammonium nitrate at a temperature of 190 °C,
cracks appeared in the ceramic liner of the meters as a consequence of
the thermal stress. This lead to repeated failures of the instruments. After
®
successful test measurements with a portable FLUXUS ADM flowmeter,
the magmeters were replaced by stationary ultrasonic flowmeters from
FLEXIM. The latter have now worked trouble free for two years.

FLEXIM ultrasonic flow transducers


with the formerly used magmeter below

FLUXUS®, WaveInjector® , and PIOX® are protected trademarks of FLEXIM GmbH. Copying and distribution allowed only with the written permission of
FLEXIM GmbH. The copyright of this report, its components, content and pictures is owned by FLEXIM or by third parties. All rights reserved. The aim of
this application report is solely to give general information about the application. It does not assure the suitability of the instrument for a specific purpose.
AR-200404-DSM-EN.doc, 23/06/04, Page 1 of 1

MeasurIT Technologies Ltd.


Craan, Craanford, email: info@measurIT.com Phone: +353 (0) 53 942 8962
Gorey, Co. Wexford, Ireland www.measurIT.com Fax: +353 (0) 53 942 8963

Vous aimerez peut-être aussi