Vous êtes sur la page 1sur 8

11.

Combining
Continuous &
Variable Flow
Components
Version 2.10 1/10/2005

Bosch versus CNH

Common Parts Uncommon Terms


Power beyond
Parallel ports
Closed centre
Variable pumping
Open centre
Continuous pumping
Bosch Rexroth regard Power Beyond as another valve in the normal circuit
CNH regard it as an extension to the closed centre common gallery
2/8

SB23-LS
Inlet plate (A2) with differential pressure switchover for constant flow pump
Acting valve

STACK VALVE IN
NEUTRAL (NO
SERVICE BEING
OPERATED)

Acting valve spring


P

Pressure
compensator
measuring surface

R
Restrictor

Y
D

W
A

Pressure compensator spring

LS channel
3/8

SB23-LS
Inlet plate (A2) with differential pressure switchover for constant flow pump
Acting valve

STACK VALVE
BEGINNING TO
OPERATE
[example]

Acting valve spring (5 bar)


Pump pressure (pp)
pp = pL + 13.7 bar

Pressure
compensator
measuring
surface

Load pressure (pL)


pL = pDW - 5 bar

R
Restrictor

Y
D

W
A

Pressure compensator spring

(5 bar)

LS channel (pL)

4/8

Intermediate pressure (pDW )


pDW = pp - 8.7 bar

SB23-LS
Inlet plate (A2) with differential pressure switchover for constant flow pump
Acting valve

STACK VALVE
OPERATING
[example]

Acting valve spring (5 bar)


Pump pressure (pp)
pp = pL + 13.7 bar

Pressure
compensator
measuring
surface

Load pressure (pL)


pL = pDW - 5 bar

R
Restrictor

Y
D

W
A

Pressure compensator spring

(5 bar)

LS channel (pL)

5/8

Intermediate pressure (pDW )


pDW = pp - 8.7 bar

SB23-LS
Hydraulic circuit for inlet plate (A2) with differential pressure
switchover

1
3

4
5

6/8

SB23-LS
End plate (E3) with shuttle valve for external LS-signal

YW

R,G

Y,D

7/8

SB23-LS
End plate (EP-EHS) for electro-hydraulic controlled valves

P2
X3

YW

8/8

Vous aimerez peut-être aussi