Vous êtes sur la page 1sur 1

F

2550

2400

5125

5125

2400

2550

GROUND LVL. (TO BE VERIFIED AT SITE)

+ 11.99 M
CONCOURSE SOFFIT LVL
2500

EVS-1

7
5150

U19A

2500

SVS-1

+ 6.89 M
CONCOURSE FFL
+6.19 M
SOFFIT LVL
5

5200

+ 1.09 M
PLATFORM FFL

2000

RAIL LVL
-0.530 M
TOC LVL
-1.310 M
UNDERCROFT LVL

SECTION-AA
SCALE 1:100

ROOM SCHEDULE CONCOURSE LEVEL

ROOM NO.

U19A

ROOM NAME
ECS PLANT ROOM (ECS)

SIZE OF ROOM (M)

34.40

23.48

AREA PROVIDED (SQ.M)

807.71

NOTES
1.
2.
3.

4.
5.
6.
7.
8.
9.

10.
11.
12.
13.
14.
15.

ALL LEVELS ARE IN METRES.


GROUND LEVELS, WHERE SHOWN, ARE INDICATIVE. ACTUAL LEVELS SHALL BE TAKEN
FROM SURVEY DRAWINGS AND SHALL BE CONFIRMED AT SITE.
RCC DIMENSIONS OF EXTERNAL ELEMENTS ARE INDICATIVE ONLY AND SUBJECT TO
STRUCTURAL DESIGN. HOWEVER DIMENSIONS OF ALL INTERNAL ELEMENTS LIKE RCC
WALLS AND COLUMNS SHALL BE RESTRICTED TO THE MAXIMUM SIZES SHOWN IN THE
ARCHITECTURAL DRAWINGS.
ALL MINIMUM INTERNAL CLEARANCES ARE MANDATORY. WALL AND SLAB THICKNESS
SHOULD BE INCREASED OUTSIDE,AS REQUIRED BY DESIGN.
RAIL LEVEL SHOWN IN ARCHITECTURAL DRAWING IS INDICATIVE ONLY. ABSOLUTE RAIL
LEVEL SHALL BE DERIVED FROM LMRC ALIGNMENT DRAWING.
DIAPHRAGM WALL TO SUIT THE FINAL TRACK ALIGNMENT.
LOCATION AND NOS. OF MAIN COLUMNS SHALL BE AS PER CO-ORDINATED AND
CONFIRMED E&M LAYOUT BY CONTRACTOR.
INFORMATION ON ACTUAL SIZE OF CUTOUT AND OPENINGS SHALL BE AS PER E&M
DESIGN.
ESCALATOR AND LIFT SIZES ARE INDICATIVE AND FINAL SIZES SHALL BE AS PER
MANUFACTURER'S REQUIREMENT AS FINALIZED BY LMRC AND THEIR PIT DRAINAGE TO
BE AS PER E&M DRAWINGS.
REFER PLUMBING DRAWINGS FOR PLUMBING AND DRAINAGE LAYOUT.
ACTUAL SIZES OF CUTOUTS AND OPENINGS IN STRUCTURAL SLABS AND WALLS SHALL
BE AS PER SEM DRAWINGS.
STRUCTURAL WALL PROFILE AND TBM SHAFTS SIZE TO SUIT THE FINAL TRACK
ALIGNMENT AND AS PER CONTRACTOR'S DESIGN.
ALL ABOVE GROUND STRUCTURES TO BE DESIGNED AS PER DETAILED ARCHITECTURAL
DRAWINGS.
LAYING SCREED ON BASE SLAB( IF REQUIRED) IN UNDERCROFT IS INCLUDED UNDER
SCHEDULED A OF BOQ (i.e. LUMPSUM PORTION OF WORK ).
SUPPLY & INSTALLATION OF THE EMBEDDED PIPES OF WATER, SEWAGE & DRAINAGE
WORK AS PER REQUIREMENT IS INCLUDED UNDER SCHEDULE A OF BOQ (i.e. LUMPSUM
PORTION OF WORK ). FOR EMBEDDED PIPES REFER PLUMBING DRAWING.

ABBREVIATIONS
ALS
CD
CONC.
EFO
ELEC.
EVS
E&M
FHC
HVAC

WALL SCHEDULE

KEY MAP

LEGEND
SEC. / ELEV. NAME

-DRAWING NUMBER

200 THK. RCC

1000 THK. RCC, 400 CAVITY


200 THK. CONCRETE BLOCK

1000 THK. RCC, 200 CAVITY


200 THK. CONCRETE BLOCK

400 THK. RCC

200 THK. CONCRETE BLOCK /


230 THK. FLYASH BRICK WALL

400 THK. RCC, 200 CAVITY


200 THK. CONCRETE BLOCK

RCC WORK

R1

BLOCK WORK

MNGR/Electrical

MNGR/Arch

Dy CSTE

Dy CE / Civil

Dy CEE / RS

Dy CE / Design

CEE / RS&S

1000 THK. RCC

600 THK. RCC

CE / Design & Track

CPM

R1

LT.
OTE
PLT.
ST.
SAD
S&T
SVS
TEF
TVS
UPE

ASSISTANT LINE SUPERVISOR


COOLING DUMPING
CONCOURSE
EXCESS FARE OFFICE
ELECTRICAL
EXHAUST VENTILATION SHAFT
ELECTRICAL AND MECHANICAL
FIRE HOSE CABINET
HEATING AND VENTILATION AIR
CONDITIONER
LIFT
OVER TRAIN EXHAUST
PLATFORM
STAIR
SUPPLY AIR DUCT
SIGNALLING AND TELECOM
SUPPLY VENTILATION SHAFT
TRACK WAY EXHAUST FAN
TUNNEL VENTILATION SHAFT
UNDER PLATFORM EXHAUST

SYMBOL
C1
C2
E1
E2
FP1
FP2
S1
S2
U1
U2
U3
U4
V1
V2
V3
V4
O1
O2
O3
O4
EVS 1
SVS 1
TVS 1
EVS 2
SVS 2
TVS 2

TECHNICAL SHAFT SCHEDULE


NAME
COOLING - DUMPING CUTOUT
COOLING - DUMPING CUTOUT
ELECTRICAL SHAFT
ELECTRICAL SHAFT
FIRE & PLUMBING SHAFT
FIRE & PLUMBING SHAFT
S & T SHAFT
S & T SHAFT
UNDER PLATFORM EXHAUST
UNDER PLATFORM EXHAUST
UNDER PLATFORM EXHAUST
UNDER PLATFORM EXHAUST
SUPPLY AIR DUCT
SUPPLY AIR DUCT
SUPPLY AIR DUCT
SUPPLY AIR DUCT
OVER TRACK EXHAUST
OVER TRACK EXHAUST
OVER TRACK EXHAUST
OVER TRACK EXHAUST
EXHAUST VENT SHAFT 1
SUPPLY VENT SHAFT 1
TUNNEL VENT SHAFT 1
EXHAUST VENT SHAFT 2
SUPPLY VENT SHAFT 2
TUNNEL VENT SHAFT 2

SIZE
2700X1200
2700X1200
1000X3500
1000X3500
1000X1200
1000X1200
1000X1500
1000X1500
1100X1100
1100X1100
1100X1100
1100X1100
1500X1000
1500X1000
1500X1000
1500X1000
2000X1000
2300X900
2000X1000
2300X900
2500X4000
2500X4000
4500X4500
4400X2200
4400X2200
4500X4500