Vous êtes sur la page 1sur 53
RRV KABEL INDUSTRIAL RANGE WIRES ARE THE NERVES OF A NEW ECONOMY, A NEW INDIA. z : ally RRV KABEL Electricity has evolved from a scientific curiosity, to a luxury of the affluent, to a modern need. We take electricity for granted one second and gawk at its power the next. One only needs to consider the consequences of 2 relatively short power outage - factories close down, phones and computers go dead, traffic slows to a crawl, food spoils in refrigerators. So there is a very intimate liaison between electricity and society Electricity powers our world and our bodies. Harnessing its energy, containing something as infinite as energy is not easy. That is what wires do. And yet, wires are like unsung heroes. Wires selflessly, continuously bring things to life. Spread high and low, across the length and breadth of the country, empowering, bringing convenience and productivity into our tives. And yet we do not spend a moment understanding the importance of the right wires for our homes and offices, To the ordinary buyer, no two wires seem different but there is a high degree of technological dynamism and this goes 2a long way in savings and safety of the premises, Just like nerves, without which we cannot do anything at all. Wires are entrenched in our homes, behind walls, through conduits, hidden in the corridors, laid under roads, But never quiet. Never idling. Wires move on, working relentless in unimaginable numbers, throughout the city, surpassing regions and binding India like a body of nerves, strong, sensitive and pulsating, BHARAT KI NUBZ HAIN HUM. Management System Certifications International Certifications: CANADA + DENMARK + FRANCE - GERMANY + UK « USA + CE — ENDURANCE RR Kabel has always made the latest advances in wire design and engineering. RR Kabel wires have outstanding performance characteristics and represent contemporary design. We at RR Kabel think wires are not just objects, we believe that wires play the role of nerves in the body. ‘And therefore we make wires a subject of scientific, design and engineering inquiry. When you believe this you have designers, engineers, fabricators, and other partners who need to have incredible design and commitment to pursue and create a product that can be trusted, and relied upon. Industrial wires work in extreme heat and cold, or chemical and radiation environments. They need to have the versatility to be hard or soft, small or large, structured or arbitrary, stiff or flexible. The future of such design lies with innovation to push boundaries, eliminate borders between sciences. The materials we use may sometimes be unique, sometimes experimental, many are collaborations but they all represent extraordinary research and dedication by engineers, designers and visionaries. RAM RATNA GROUP Powering Ahead Ram Ratna group believes in sound strategies productively coupled with responsibility to advance ‘goodwill, while building sustainable and impressive businesses. We respect the process of integrating social values and mission within business decision-making process. This helps us set guidelines to achieve product quality, economic accountability, social responsibility and aim for industry leadership. Our group believes in giving back in every way possible. It promotes ‘linked prosperity’ between the company, our employees, our partners and the community look at each of our group company reveals that we achieve positive and sustainable outcomes towards the business and the community at large. Index Sr. No. Cable Detail Page No. 1 Ratnallex Single Core 182 2 Ratnaflex -M_ 3&4 3 Braided Cable 5&6 4 Shielded Cable 70 10 5 Control Cable JZ - 500 flexible a2 6 XLPE CU Control Cable UNARM/ARM as per |S: 7098 P-1 13 to 16 7 PVC CU Control Cable UNARM/ARM as per IS: 1554 P-1 17 to 20, 8 XLPE Arm Cable 3 core, AL/CU as per IS: 7098 P-1 21822 e XLPE Arm Cable 3.5 core, AL/CU as per IS: 7098 P-1 23 & 2h 10 XLPE Arm Cable 4 core, AL/CU as per IS: 7098 P-1 Ww PVC Arm Cable 3 core, AL/CU as per |S: 1554 P-1 27 & 28 2 PVC Arm Cable 3.5 core, AL/CU as per IS: 1554 P-1 29 & 30 13 PVC Arm Cable 4 core, AL/CU as per IS: 1554 P-1 31832 4 XLPE Unarm Cable 3 core, AL/CU as per |S: 7098 P-1 33 & 36 5 XLPE Unarm Cable 3.5 core, AL/CU as per |S: 7098 P-1 35 & 36 16 XLPE Unarm Cable 4 core, AL/CU as per IS: 7098 P-1 37 & 38 W PVC Un-Arm Cable 3 core, AL/CU as per IS: 1554 P-1 39 & 40 18 PVC Un-Arm Cable 3.5 core, AL/CU as per |S: 1554 P-1 AVR 42 19 PVC Un-Arm Cable 4 core, AL/CU as per IS: 1554 P-1 43 & 44 20 Silicon Rubber Cable 6 2 Welding Cable w 2 Submersible Cable IS: 696 1990 a RATNAFLEX Single Core flexible cables for electrical panel switch boards upto and including 1100 V Conductor : Electrolytic grade annealed copper with high flexibility Class 5 and uniform resistance properties, Conductor with ‘Annealed tin copper can also be made available on request. Insulation : All insulation grades in PVC exceed the requirements as stated in 15 $831. All grades of insulation offered are RoHS compliant, Table 1: Variants available RoHS, COMPLIANT Cable Colors : Available in Red, Yellow, Blue, Green, Green / Yellow, Grey & Black. Other colors available on request. Legends in Marking on Cable : RR KABEL, Ratnaflex SI, CM /L, CE Packing: Standard packing of 100 meters in coils. Longer length available as per request. [RATNAFLEX FRSA] 6 Applications Specitiations| RATNAFLER —[Saneraliring of panels Tor] 15 694, 158130 use inmax operating | Class, 15831 temperatures upoand Including 70 RAINAFLEKFR | Wringin igh density & |S 894, Category C1, critical installations | Wiring in pubve places & | fire prone areas 8130 Cass 5, 15 5831 [IS CalegoryCZ, S| 8190 Class 5,15 5801 Table 2: Cable as systems Brand ‘Specifications RRKABELHFFR | Wiringforcriieat | IEC 60228 Glass 5, IEC instalation in public places | 60332-183, IEC and in vicinity of electronic | 4075-182 IRR Pvc ascrTOsG| Tahigh ambient temperature panels which ‘an withstand upto and including 105% BS OURO EK BS 6231-type Ck, UL 1549 300, ULI015 6004, UL1275 6009 Pree ‘Wiring in public places & fire prone areas Bie, Caegey en 8100 Clases, 85831 Physical and Electrical Properties Nominat | WireG8u9® T No. ofstrands/Max | MaxDC Conductor | Nominal Insulation | Nominal Diameter | Max. Permissole Cross section Strang Diameter | Resistance at 20°C | Thickness ‘over Insulation current rm? mm fk mm mm ‘Amps a 2 e702 30) ue za 5 075 20 74/02 260 ae 23 a a 5 2/02 195 os 25 = 1 30/025 133 0 20 7 2 1% 30/028 198 a7 35 2 “0 2 54/03 295 a8 a 0 20 0 4/03 330 aa “8 = 700 @ woos 1 7 2 = 160) é 126/04 12 10 7 7 250 “ 1960 700 z as © 50 2 2r6fe 0386 2 10, 17 500 1 96/0 86 1 Tas ue Too 2 36070 oan 1 160 ae 50 aio 20705 0206 7 1s 262 00 a 08/0 O61 7 183 310 1500 MoM 50/05 a2 a 215 8 750 350 40M 31/05 0106 20 25 as 2000 Soom 1200/05 0.080% 22 20 50 3000 50 MoM 1500/05 06st 2a 2o 0 soe : 2013/05 0486 2 m0 0 S000 : 02105 386 28 m0 rm 00 z uiWOs 0267 28 as 75: Note:The configuration mentioned above ae for reference purpose only. The conductors shall meet the resistance requirements as per class 5, 15 8100 ote relevant standards as applicable. Ratnaflex Single Core: RATNAFLEX-M Multicore flexible cables for appliances & machine tools upto & including 1100 V RoHS, COMPLIANT Flexible cables PVC Insulated and Sheathed for appliances & machine tools upto & including 1100V compact construction, Rugged yet flexible for industrial use. Combination of sheath available depending on type of application. Conductor : Electrolytic grade annealed copper with high flexibility Class 5 and uniform resistance properties. Conductor with anneated tin copper can also be made available on request. Insulation : All insulation grades in PVC exceed the requirements as stated in 15 5831, All grades of insulation offered are RoHS com= pliant Sheath Colors: Generally available in Black and Grey colors. White and other colors are offered on special request Packing: 100 mtr. coils, Longer length made available in suitable wooden drums or spools, Table 2 Color codes Legends in Marking on Cable : RR KABEL, Ratnaflex M, 151, CM/L, — of Blok. Gy Tale Uvaabeon request HRTNAFLEN | POW re or aU Bee Bai a Wing oT 5, San aed] eran 00, WOE VTS ‘tater ie 501 spares es une EL or a UL 254-00, UL 2576-150 ———1 spicaonera 85600, L287 Table: Cable design da witgetwptanes ene No.ofcoresx | Nominat | Nominal] — Nominat em Nomina rast | Insulation | sheatn | Cabte Novoteoresx | Nomina] Nominal] — Nominat ise wn ee Nominat ross | Insulation | Sheath cable Shale core sheathed cable Coren? mm mm mm 7x08 Te oF a Round sheathed cable TOs Ts T az Tx Te oF 7 Tas Tr o a Tos o5 = a T7 a 34078 os oF ea 125 ws 7 55 5078 7 1x60 as 7 a Sx 075 “ a a oF Tal a 110 u 7 Br ar os os 7 116 12 7 35 Tat 7 1125 17 x wT 7a] 1% 12 z Ta Am os i 130 12 1s 3x15 7 as 82 Twin sheathed cable tas o 2 TE TH T TORT Sul TE Te o BART Dts a a Tat Te a7 ETA ye os r 95) Round sheathed abe 4x28 10 ios oF a = oe oy aa 2x4 a 7] 4x05 w oF axe os ot ne 3 axe 10 ing Table &: Cable design data No. of cores x Nominat Neminat | Neminat No.of coresx | Nominal ‘Nominal Nomina Nominal Cross | Insulation ‘Sheath cable Nominat Cross | Insulation ‘Sheath ‘cable section Thickness | Thickness | Diameter section Thickness | Thickness Diameter Cores/mm? mom mm omm Cores/mm? mm mm mm Round sheathed cable Round sheathed cable 2x6 1 2425 1 205 3x6 08 T 3x25 2 15 z x6 TZ 2x25 Te Te 2x0 12 2x38 75 Bz ax 10 1 3x5 12 16 7 x10 a5 7 aT, 2xie 2x50 e BE 3x18 10 3x50 1 a7 Bi xi iz x50 78 RS Table 5. Electrical Parameters on flexible mulicre cables 15694, (Grass Sectional Area mit 08 76 1 1 25 z Noize of wire mm ef02 2al0 a2i0 ayo 30/028 seb DE resistance at 20°C Km Imax) 390 260 195 138 798 695 “Twin core Amps 35 oS 7 % 18 2 Three core Amps a 5 = 1 1% 18 Four core Amps 25 a = 0 a 7 ble 6 Electrical Parameters on feibe mul core cables 15496 Cross Seetional Area mim @ @ 1 @ % qi Noize of wire mm Bao amos 20k Teel Pela a96fo DE resstance at 20°C OK Imax) 330 131 121 ove 0554 0.86 Twin core Ams 2 2 36 7 2 re Three core Amps: 2 3 my 36 n 7 Four core Amps. @ 30 o 2 e 7 Table Color codes The conformity of conductr strand Note Table +, the current rating mentinedi indicative for ambient temperature of 40°C meter and conductor resistance isa pr the requirements ofS 694» 15 8190 Type. Core colors Single core sheathed ed Yellow, Blue, Black Orey Twin lat sheathed Red, Black Twin round sheathed ed, Black Three core round sheathed Red, Black & Green Four core ound sheathed Ted, Yellow, Blue & Gree! Ratnaflex-M They ae use 2s power cor for appances such as Hi - power apallances Uke ovens and as temporary (Data Transmission Cables) Cable Structure + Annealed plain flexible copper. + Special grade of PVC insulation. + Colored cores upto & cores. + Black cores with white marking for § cores and above. + Cores twisted suitably to form a round shape. + Covered with insulating plastic fi. + Sereen braiding generally of 65-7 copper. + Special grade PVC outer sheath + Sheath color Grey / Black. with Fine Annealed tin Conductor : Class 5, IEC 60228, VDE 0295. Braided Cables: BRAIDED CABLE Specific Insulation Resistance : 20 M Ohm Km. Temperature Range Flexible application : -5 to =70°C Fixed application :-20 to +80°C Min Bending Radius Flexing : 20 x Cable diameter, Fixed Installation : x Cable diameter. Test Voltage Core/eore :4000V Core/shield : 2000 Rated Voltage : 300 / 500V Braided cables are most suitable far interconnection of electrical measuring devices to instrument panel or instrument. They are used for measuring, monitering and controlling machine tool manufacture, plant engineering and in all places where electrical interference fields can distort a signal transmission. Table-1 Table-2 No. ef ‘Approx Approx Approx No. of ‘Approx Approx ‘Approx cores x Cross cable Copper cable cores x Cross cable Copper cable seetionatarea | diameter | weight weight sectionatarea | diameter | weight weight mm 8mm Kafer Kafken mm? amm Kafken Ka/km 1025 38 70 1x05 rm 5 0. 2025 3a 310) 2x05 63 290) 50. 3025 36 360) 3x05) ma 390 36.0 ex025 60 00. x05 72 60. oo 5x25 6s so 5x05 eT 320) 760 x025 70 580 x05 72 660. om 70.25 72 60 7x05: Ta 0. 780 x025 7 220) x05 73 200) n70 10x 025 a7 50) 10x05 29 30) 1350) 12x 025 20 900) 12x05 92, 170 137.0 Tex 025 2 140 1x05 3 722.0 190.0 Tox 025 39 7100 1x05 io 729.0 2100 18x 025 Toe 20 1x05 706 7520 270 19025 108 x} 19x05 TF 756.0 266.0 720x028 m3 182.0 20x05 126 70 218.0 2610.28 02 162.0 2x05 137 236.0 37.0 2540.25 125 169.0 25x05 139 250.0 27x02 727 176.0 x05 10 265.0 orien] ance’ | meagre | zea on waz | 20 [sino mm? Omm Ka/km Kallen xe 134 328.0 400.0 as ie fear. cer] me aa 1s? 55 39.0 50.0 5x10 198 714.0 856.0 2428 90 60 1300 7x10 26 820.0 1300.0 6 SHIELDED CABLE Overall Shielded PVC / PVC [300/500 V) Construction Conductor : Annealed copper wires according to Overall Screen : Aluminium / Polyester tape 0.024mm in electri- class | or 2 or § of BSEN 60228, cal contact with tinned annealed copper wires of a total section of 0.5mm? Polyester tape 0.05 mm thick overall bended. Insulation: PVC Type TISt according to BS EN 50290-2-21 ‘Outer Sheath: PVC TYPE TMS1 according to BS EN 50290-2-22. Pairs Twisted Marking: RR KABEL m x1 x 300/500 V PAS 5308 - Part 2. Identification Pairs: Blue & White, Blue cores indicate pair identification Application: PAS §308-2 Design Guidelines. ‘Assembly: Concentric layers. Standards: 0332-1 Flame retardar Lem” [ender tml | t20%6 (0m) [instaton(mmi] paste tape vm) | approx ml [appro ep | rade rm Fawn | x08 a wa ai a a @ 7 Teexosa | oF a0 2 50 a7 a 0 Faxon | 612105 a a0 2 v0 133 9 160 oases [oF 390 zi a7 182 15 Wsxzx0s | a9 wa 2A 162 1a 220 maxzx0s | a9 wa 2A Tae a2 250 woxexos | __as wa 2 mar ae aia Frown | 200.78 1 260 Fa 4&6 62 0 ravone) sx2x07s | 1 2 2a i m7 212 180 ioxex07s |__¥ 20 2a 150 1a 210 ix2x075 [1 260 22 118 7a 250 moxzxors | 1 260 22 7 ms 720 want | at 16 im 29 37 7h 0 Teentsa | 16 im 29 a a 10 RaNOHA| 632415 16 1 29 1a Te 210 iox2e1a | 16 a 29 as a2 sei 28 weet | 16 v 29 a 2 250 aca wxznts | 16 12 29 % m2 9? 3a BOxtat 16 in 29 mar 2A 1612 a0 Individual & Overall Shielded and PVC/PVC (300/500 V) Construction Conductor: Annealed copper wires according to Class 1, 2or § of BS EN 40228. Insulation: PVC type TI51 according to BS EN 50290-2-21 Pairs: Twisted Identification Pairs; Blue and White, Blue cores indicate pair identification. Individual Sereen: Aluminium / polyester tape 0.024mm in electri cal contact with tinned annealed copper wires of a total section of 0.5mm? polyester tape 0.023 mm thick bonded. Assembly: Concentric layers. Overall Screen: Aluminium / Polyester tape of 9.024 mm in electri- cal contact with tinned anne: fed copper wires of a total section all bonded. 0.Smm? polyester tape 0.05 mm, thick ov Outer Sheath; PVC type TMS! according to BS EN 50290-2-22. Marking: RR KABEL - nx - m x a 300/500 V BS 6208 - Part 2. Applicable: PAS 5308-2 Design Guidelines. Standards: IEC 0322-1 Flame Retardant. Type | crosesection] Diameterof [Maximum DC resistance] Diameter over [Diameter over assembly [Over elameter| Weight of eable | Min bending Imm!) [conductor mml] at 20°C [n/krn) insulation ml] plastietape (mm) | approx. (mm) [approx kg/km | radius (rm) jrmxnonR] PxPx08 oF wo Ba zy az 708 a0 Ex2x05 oF 30 2A Te 1a? Ho 170 10205 oF 30 2 Try 169 259 200 Tox2008 oF 390 2 168 198 a7 2a B0x2x05 oF 30 2 25 70 220 FRRHONR] 2x2x0.75 7 260 2a ay 109 120 Sx2x075 1 260 2a 125 ee 10 TOx2x078 1 260 Fy 15S a2 a 220 xDxDTS 1 260 2 183 2h a 20 H2KO7S 1 260 2a 210 25 ei 295 Wx2K078 1 260 2a 27 28 12 260 IRaxnone) 2x21 1 7, 2 1a 133 10 xP 1 7, 29 152 179 a 25 We 2¥ 15 1 7, 29 187 220 a 20 1Sx2H1S 1 12. 2 223 258 82 a0 24218 1 7, 23 257 2 Tae 350 BWx2a18 1 7, 2 ae we 177 a0 ‘Applicable identiication Codes: Conductor: F-RounéFexbe, R- Round Rigi Conducta, Insulation: R-PWC Insulation Assembly: O-Laid Us Pairs, Twisted Pairs, Shielded Cables SHIELDED CABLE Overall Shielded Armoured PVC / PVC (300 / 500 VI Construction Conductor Annealed copper wires according to class 1 or 2 or 5 of BS EN 60228. Insulation: PVE Type TIS) Pairs - Twisted ‘ording to BS EN 50290-2-21 Identification Pairs; Blue & White.Blue cores indicate pair identification Overall Sereen : Aluminium / Palyster tape 0.024mm in electrical contact with tinned annealed copper wires of a total section of 0.5mm? Polyester tape 0.023 min Bedding: PVC TYPE TMS! according to BS EN 50290-2-22, Armour: Outer Sheath: PVC TYPE TMS1 according to BS EN 50290-2-22. Markings RR KABEL n x rm x 2 300/500 V PAS 5208 - Part 2 Application: PAS 5208-2 Design Guidelines. Standards: 0392-1 Flame retardant IEC 60332-¢ Flame retardant on bunched cables (it applicable! Type Prosesectonprameter ef] Maximum | Diameter | Dimeteraver | Diameter | Oiameter | Oameter | outer | welghtat | Min Imm] | conductor OC resstanca ver insulation assembly plastic over inner at Armour bvar Armeur| diameter fable approx| bending Umm) [20°C (afkml] Irv) | tape mm) _fsheathlmmlfires (mm) rm! approx Imm) | thar [rads mm) [renner | 2x05 | on 0 2 rH oF or | a Ey 7 mos | os 0 2 a m or | 86 7 on lraronnen| Sx2x05 | 09 30 2A 10 na [ | se Fy 1 10 Wox2x05| 09 a0 2A 137 2 [| ar Tea 786 195 Wex2x05| 09 0 2A 12 vere | a ai 0 zox2x05| 09 0 2A my a2) | 2a a2 308 aox2x0s|_o9 0 2 wr m2) | a Be 7 a0 xo [1a 260 2a tb 72 oe | #0 72 a 0 [Fexonnee| Sx2x078 1 260 2a 2a we [oe [om oy 22 10 Wox2e075| 1 260 Fy wr | 16 |e ia 360 210 Tex2e0r8] 1 260 2a 78 me |e | 6 We 300 w0x2x075| 1.41 260 2a 29 ma [20 | ma 7d 76h at Iamwinrn | 205 | 16 Wa 2a 37 Ta ar | 92 7 % oy tas | 16 72 2a SF 7 or | 10s 3 150 10 Iaexounee) Sx2x1s | 16 72 28 ae we [oe [4 ie 328 20 Toxteis| 16 21 28 a5 ne | 16 | 2h 72 381 2 Wx2ats| 16 21 28 ae me |e | ae we 200 Box2x15| 16 Wa 2a 7.1 maz [20 | ae 702 ae aoxexta] 16 72 2a 37 aan) 20 | a8 3a Te a0 Individual & Overall Shielded Armoured PVC / PVC (300/500 V) Construction Conductor: Annealed copper wires according to Overall Sereen: Aluminium / Polyester tape of 0.024 mm in electri- Class 1,2 or § of BS EN 60228, cal contact with tinned annealed copper wires of 2 total section (O.Smm? polyester tape 0.05 mm, thick overall bonded. Insulation: PVC type TI51 according to BS EN 50290-2-21 Bedding: PVC type TMI according to BS EN $0290-2-22, Pairs: Twisted Armour: Galvanized steel wire Identification Pairs; Blue and White, Blue cores indicate pair identification Outer Sheath; PVC type TMS! = ding to BS EN 50290-2-22. Individual Screen: Aluminium/polyester tape 0.024mm in electrcal Marking: RR KABEL -n x- mx csa 300/500 V PAS 5308 Part 2 contact with tinned annealed copper wires of a total section of 0.Smm# polyester tape 0.023 mm. Applicable: PAS 5308-2 Design Guidelines. Assembly; Concentric layers. Standards: IEC 0392-1 Flame Retardant EC 60332-1 Flame Retardant on bunched cables lit appticablel Tae wa [aenaer | wacinun | aianater | eraser ave | oiawster | damater| wave | outer | waignat | win Fan] [eanduster | reslatay: Insuiatlon paste ansata fodesa(nol] Armour | saavax. anorax. “ae a inal | taateat_| Ina Goal [twat | ceatem [Cont rrawonrn | 2x05 | om a0 zi a2 o_ | a [m7 2 |» ux05 | on 390 2 42 Ce ma |» ioxax05 | a9 2 wa ea) ta | ter | tea | ame) Wa2x05 | a9 2 Fe mox2n0s | 09 z es aa 16 | me _[ nna | ooo | a0 Fanon [avxax08 | 07 390 zi nr [ a2 [16 | ma _| ma | ms | ao ax078 [1 Fa & sap as [er | aa 3 |» axe | 23 a a weano7s | 260 2a a4 we [ ta | wa | ea | oxex07e| 260 2 5 v7_[ 16 | m9 | wa _| 20] a0 2x07 1 2% 22 ve [ aa [16 | me | 204 | sw | 50 rraionnen [7047x075 [ 1 240 Fa ma [m5 [er ees _| 200 oxzx075[ 1 % 2 ua | aaa | 20 | sea eeu | ven) 2 16 Bi 2a 57 7 [a9 [| 7 | | tis] 18 ai 2a 37 e7_| es _[ os] 9a so 110, beets [16 721 2 ue [_«s [ia | a_| wa | me | avo oxtx1s |_16 21 2 es [aa @ me [aa oer [ass ‘Applicable dentieation Codes: Conductor: F-Round Flexible, R-Rouné Rigi Conductor, Insulation: &-PYC Insulation Assembly: Old Up pais, Xtwistd Pas, Metal Seoen:H-Alaminum Tape sereen, Armour FStel Wire Arr, Cable Sheath: R-PYC Sheath, Cale MaFKng: =n of Sar, my -Twised pis, eoes sectional aes Shielded Cables 10 JZ - 500 Flexible Technical Data: + Control cables, special PVC + Requirements adapted to DIN VDE 0245,0281,0293,0295 + Temperature range: + Flexing -S°C to + 80°C + Fixed installation -20°C to + 80°C + Nominal voltage: Uo/U 300/500 ¥ + Test voltage 4000 V + Breakdown voltage: Min. 8000 + Insulation resistance: Min, 20 M0 x km + Minimum bending radius: flexing 7.5 x cable & + Fixed installation: 4 x cable @ Cable Structure + Bare copper, fine wire conductor, according to DIN VDE 0295 CLS, BSEN 60228 CLS and IEC 60228 CL 5 + Core insulation of PVC TI2, to BS EN 5036-3 Insulated Conductors: CONTROL CABLES + Core black with continuous white numbering according to DIN VOE 0293 + Green - Yellow earth core in the outer layer [3 cores and abovel + Cores stranded in layers with optimal length + Outer sheath of special PVC, TM2 to VOE 0281 part 1 and HD. 21.1, BS EN 50363-4,1 + Color grey (RAL 7046) Properties: + Extensively ol resistant + Also available with PVC selt- extinguishing and flame retardant ‘according to VDF 0482-332-1-2, IEC 60332-1-2/IEC 60332-1 (equivatent DIN VDE 0472) part 804 test method B) The materials used in manufacture are free of cadmium and contains ne Silicone and {ree from substances harmful tot wetting properties of lacquers Note: G = with Green - Yellow ea = without Green - Yellow earth core (02 Section | Insulation Insulation Resistance at 20°C Number of Core mm Kg/km weep | maior | oetn, | espana 0.50 0.3/0.4 1.60 39.0 S608 6 st 0.75, 0.3/0.4 1.80 26.0 SG08 SI ie 1.00 0.3/0.4 2.00 19.5 7808 14 ot 1.50 0.3/0.4 2.20 13.3 8605 8 106 2.50 0.4/0.5 2.85 7.98 1060.5 a8 129, * According to CLASS-5/IEC 60228, BSEN 60228, DIN VDE 0295 1608 88 133. Nonna secionmne | Maestnesneeartenuties | [Ison © vr 0.75, 26x 0.2 1960.5 W4 216 11 INSULATED CONDUCTORS: INSULATED CONDUCTORS: Nominal section mm?x | Cable dimension | Approx.cablewt | | Nominal sectionmm'x | Cabledimension | Approx Cable wt Number of Core mam kg/km Number of Core mom kg/km 56075 6a @ Bois ae 13 660.75 75 700 eats 8 156 78075 at 116 7618 28 186 260.75 a2 138 eats 108 26 7060.75 26 16h wos1s n 266 1160.75 96 18 iets mW 25 1260.75 29 182 2618 124 27 1260.75 Toe 209 14615 129) 236 1600.75 ay 2a7 T6615 138 380 1700.75 7 261 7615 145) 24 1960.75 123 263 EIS 152, ue 2000.75 126 297 20615 152, “9 2400.75 45 381 SE 178 oe 2760.75 152 221 2615 707, 5610 6 7 3828 102 208 6610 8 19 e825 15 260 7610 36 3 7528 121 26 e610 ay 18 8625 132, 3h eo To 201 70825 5 3 Teo Toe 208 i625 15 455 e10 io7 222 152 a9 mete zy 252 16 Bee esto 1% 286 7 oS Were 127 Ey ie o9 Wee % 337, 184 75 20610 135 300 203 832 mero Ta7, 2 22 998 wet Tse 90 2 1083) Control Cables cheaihing has been removed the numbers hive been underline 1 v0 confusion Th extn core i a Se ayer, Selected Compound guarantees good texbity ae wll asa fast and economic 12 1.5 sq. mm AS PER IS 7098 P-1 XLPE Cu CONTROL CABLE UNARMOURED / ARMOURED Technical Detail For 1.5 sq. mm Copper Conductor, XLPE Insulated Unarmoured & Galvanized Steel Strip / Wire Armoured Control Cables Type / Code Of Cable: 2XY / 2XFY / 2XWY, as per IS 7098 (P-1) Conductor: Cu conductor solid as per class -1 or stranded as per Class-2, 15 8130. Insulation Material: Crosslinked Polyethylene XLPE Compound Insulation Thickness 0.7 mm. Inner Sheath: PVC / PVC tape as per IS 7098 (P-1) A. Cable Design Parameters Armouring: Single armouring of Galvanized Stee! Strip / Wire Outer Sheath: PVC Type ST-2 as per IS 5831 (Option: FR Type/ FRLS Type. Color of Outer Sheath: Black. (Options: Any other color as per requirement! Unarmoured (27) ‘Armoured with Flat Strips (KEY) ‘Armoured with round wires (WT Minimum | Wom. | Approx. Nom. Min. Tie Thickness [Thick of] gyerat | Approx. [Nom Thick] Min. Thick Diameter | of outer No. | otinner | outer sfStrip | ofouter | Approx. | Approx, | otwire | sheath | Approx ot | sheath [sheath] 9% | Netw. — | forarm. | ‘sheath | overatl | "Net | fordrm. | mm | Overa | App. Net cares | mm | mm | mm _[orcabieksikm| mm | mm | is.mm | wtKaikm | mm Dia,mm_[ we Kalk 2 [03 [16 | 100 wa [Nik wa_| wa | 14 2 15 300 a [03 | 18 [105 Nia [Nik wa [wa | 14 | 128 [122 390 ~[ 3 18 |_us 200 NA _|_NA wa [wa | 1 | 1% | 190 a5 s [os [1s | 1s 25 WA |_ NA wa | NR 1 | e137 us s [es [ie [3s 250 wa |W wa [wa [14 26 ab 00 f [oe [5 248 Nia [Nik wa |_N 1 26 6 520, wf 03 [1s | vo 340 Nia [Nik wa | wa [14 | 128 | 10s 55 2 18 |_75 390 NA [_NR wa [wa [16 | 140_[ 190 720 1 18 |_180 a WA [_NAA wa [wa [te | 140 [00 m5 16 18 | 135 a 10 7 750 1 a [a0 26 20 | 5 5 140 2 wooo [16 | 140 | 250 Fa 20 | m0 750 vo | as | 100 [16 | 140 | 255 30 20 | 25 wD 140 Ey ims [| 16 | 140 | 20 a] 20 | 260 oes 10 26 is [te | tao | 20 wo [_o 20 | 760 1050 a [10 | ms | wo | 16 ao | 295 20 | reo | _1500 140 | 25 | 100 | 16 se [205 2 20 | m0 120 ise | 05 | 100 [| 16 | 156 | 220 a 22 | sto 1500 156 2 iso [20 [tse | 345 B. Electrical Parameters Waximum Cond, | Approx CondsAG, | Approx ‘Approx De. Tensioner | Reacanceot | Copacteee | NO™AYCHrentRatnginAmps | Short cut Current Resistance roe cneasoe | cone vith XLPE Insulation Rating for 1 see Duration ores ‘ken Inalkm inalkm | mero [Ground [Due Bir |_ MIN ALPE rsstation 2 T24 152 oN CRs 00 Fa tae 3 2. 152 a Rs a0 wo ois é 21 52 on 096 280 wo Dai 5 2.1 52 ol O96 70 20 as é 21 52 a eave 208 180 as 7 2 152 a one 195 a0 Dae 10 2 152 a Rs 180 1s 2s 2 21 152 on 076 70 14s 215 0 21 52 ol 096 z us ais é 21 52 a ene 55 130 aais 7 wa 52 oa cane us 130 oa ra 2 152 a Rs a0 120 ois a 21 152 oo 076 10 120 0215 2 21 52 on 076 20 os ais @ 24 52 oa are on 8 105 oa ma wa 152 an Rs 700 5 2 oie 2 12 152 on Rs 25 75 80 0215 ¢ 21 52 on 076 as 7 7s ais XLPE Cu Control Cables : LPE corral cables ae used in industrial power or contra cic for conveying lace signals the esocate devices, There cables can be id in tunnels, cals trenches, indoors, pipelines, aidges an 14 XLPE Cu CONTROL CABLE UNARMOURED / ARMOURED 2.5 sq.mm AS PER IS 7098 P-1 Technical Detail For 2.5 sq. mm Copper Conductor, XLPE Insulated Unarmoured & Galvanized Steel Strip / Wire Armoured Control Cables Type / Code Of Cable: 2XY / 2XFY / 2XWY. As per |S 7098 (P-1) Conductor : Cu Conduct class-2 15 8130, solid as per Class-1 or stranded as per Armouring: Single armouring of Galvanized Steet Strip / Wire. Outer Sheath: PVC Type ST-2 as per IS $831 Option: FR Type Insulation Material: Crosslinked Polyethylene XLPE Compound. FRLS Type. Insulation Thickness 0.7 mm. Color of Outer Sheath: Black [Options: Any other color as per Inner Sheath: PVC / PVC tape as per IS 7098 (P-1I requirementl A. Cable Design Parameters Unarmoured (207 ‘Armoured with Flat Strips (2K) ‘Arimaured with round wire [2007 Minimum] Nom Nom No. |Thickres thick of Wom, thik min, thick, Diameter. Min, Thick ot Jotinner | outer | Approx. | Approx. | etstrip | etouter| Approx. | Approx. | atwire | of outer | Approx Cores | sheath | Sheath | overs’ | Netw. | forarm. | Sheath | Overall Net | forarm. | sheath | Overall | App. Net mm | mm | Biacmm fot able kg/km] rom | mm — | Gia mm | wt kp/km | mm | mm | Dia.mm | wt. Ka/km 2 [oa [a [os 70 wa[_wia_[_wa NA 1 2 25 390 a [oa [ie [us 2 wis[_wia [wa NAL 1 26 0 as ~ | oa [ie | vo 25 wa [win [wie NVA 1 2u_|_t4o 586 = [oa [ve | no wa [wa [wa NAL ve | tae « [03 [os [uo WA [Nim WA, ve | tae 7 [0a [1a [10 Ni_[_Nin NAL 1 2% w [os [is [v0 wis_[_Nia NVA 1 0 2 | os [oe | vo 08 rm 760 1 rm «| or [oe | es oa | tao a0 ve | vao % | 02 | 20 | mo oa | van a0 ve | tao ww | os | ao | ao 08 0 990 1 a z% [oa [20 | ms 08 a 210 1 a w | oa | 20 | 250 oa | tao ve | tao a) oa [20 | m0 oa | tao | 156 wo | oa | 20 | 200 08 | 156 i170 ve | 156 [04 [22 | ato 08 56 80 20 56 @ [| 22 | uo oa | ass | 2090, 20 | 156 15 B. Electrical Parameters no, | Meipecent: | Anprox sondage | Aopros free Normat* Current Ratinginamps | Short circuit Current ot Resistance Resistance J Reactence ot | Capacitance vith XLPE Insulation Rating for see Duration cores Store a0" cable atS0He| of fos [ie | wa_| Nia [WA NA 1 2 1% 310 pos [ie | wa | Nia [NA NAL 14 2h 7 570 7 [3 [te |S 30 wa [NA [Nia NAL te | 12 7 = o [os [ie | WA_[ NA [_Nm NA ve | nae Ey a0 2 [oa fie | oa | 126 1 700 ve | vat 2 00 «| os fie | 2 a8 a 200 1 a 2 780 e [oa [20 | 2 oa [| van 750 te | ao 2 10 zm [oa | 20 | 2 oa a ve | ao 2 100 zw [oa | 20 | 2 oa [van | van Ey 0 wo [oa | 20 2 oa [van a ve | vao 2 00 a [os | 20 | 2 a8 a a 1 a 3 0 @ [oa [20 | a a8 a 0 1 56 2 780 [oa [20 | a oa | 156 z | 156 2 230 we | oe | 20 | a oa | 156 u 20 | 156 36 2650, o [oe [az | s oa | 156 20 | 156 38 250 17 B. Electrical Parameters PVC Cu Control cable: These power les for energy suply are installed outdoes, are largey used in xe wiring, underground wiring as well as indstrl control o noprox Shor Circuit Current vo {inert | sexcane ac. | atte | AE Normat* CurrentRatingin amps |Rating tor See Duration ot | Resistance Resistance at | ofcable | “gfeabia | _ Witvgeneral Win Gen. | Wik Heat cores} “stz0"e Ins ats0hz | in Insulation With4R.Ineuiation | purpose | Resistance sikm [amore | aasre | insih | mierovam [Ground] Over [ air | Ground [ Ouet [alr | insulation | Insulation 2 2 use 2 | on | o2 | a [ola] «» [au fu | om | on 3 2 ws s2 | one | e2 [a full [a [a | os | oi “ a us 2 | om [oz [a fall fa [a | om | om A Ta se se | one [oz [a fwtvl a [a [a om | om é 2 use 2 | one [ez |» felel w fw [we | os [on iw it uses? | one | ea [os [uf n[ os [is [| ois [ois 2 2 us 2 | om | o2 | efelol« |e[r am 1 2 us 2 | on | oz [| [olwols [ele om 6 2 use) ee | ome | ez | fetyf[s [nfo or 2 2 use 52 | one | o2 |e [ele] w [iw [wo] ois | om z 2 use 2 | one [oz |» [els| w [i [| om | om 20 2 usr 2 | one [oz |e [7[7[w fs [es | os [om sr 2 use) 2 | one [ e2 |e frtr[ + [s [es | os | om 21 usr 52 | one | o2 |» [>]7] [ss |e | om | oi 1 use 52 [one | o2 | 7 f>tr{s [7 [7 | om | om 2 2 use sa | one | oz |» fsle[ 7 [7 [7] om | om a 2 us 2 | one [oz |» [sls| 7 [7 [7 om | om Js and in subscriber networks, where mechanical damages are not to be expected. They 18 2.5 sq.mm AS PER IS 1554 P-1 PVC Cu CONTROL CABLE UNARMOURED / ARMOURED Technical Detail For 2.5 sq. mm Copper Conductor, PVC Insulated Unarmoured & Galvanizeed Steel Strip / Wire Armoured Control Cables Type / Code Of Cable: YY / YFY / YWY. As per |S 1554 (P-1) Conductor 25-2, 158120. Conductor solid as per class-1 or stranded as per Insulation Material: PVC Type-A as per IS 5831/Option:HR PVC [Type - Cl as per IS $831. Nominal Thickness of Insulation is 0.9 mm. Upto 5 cores by colour coding & more than 5 cores number printing on core as per IS 1854 (P-1) A. Cable Design Parameters Inner Sheath : PV / PVC tape as per IS 1954 [P-1) Armouring: Single armouring of Galvenized Stee! Strip / Wire Outer Sheath: PVC Type ST-1 as per IS 5831 (Option: PVC Type ‘ST-2.as per IS 6831, FR Type/ FRLS Typel Color of Outer Sheath: Black Options: Any other color as per requirement! Unarmourea (YY) ‘Armoured with Flat Stipa (YFY] ‘Armoured with round wire [YWY) Minimum Nom, Nom No. |rnicknes| rick. of INom. Thick Min. Thick Diameter. Min. Thick at | otimer | outer | Approx. | Approx. | otStrp | afouter | Approx | Approx | otwire | af outer | Approx cores Sheath | sheath | Overa’ | —Netwt | forarm. | Sheath | Overall Net | forarm. | sheath | overatt. | App. Net mm | mm | diamm [otcanioxs/km| mm | mm | diaemm | wiAsikm | mm | mm | oiamm_ | wt, Ks/km 2 [os [ie [| 220 wa | wa | Nia NA a | tz if m7 = [os [ie |i 260 wa[ NA |_NA Nia a | tae 5 180 « [os [is [os 310 wa | wa_[_wia a [128 ie 540 = [os [ie | 20 wa | wia_[_wia a [12 i m7 é ee 390 wa | wia_[_wia a [12 3 285 73s [os | 2 wa | NA | _NIA é w 720 i [03 2 370 08 2 a % 040 2 | 03 2 mm 08 2 é 2 30 «| os [20 | 2 750 08 2 4 a 080 [os [20 | eo 08 2 é 26 80 w | os [2 3 950 08 3 é 2 60 [os | 20 | 7200, 08 2 a a 80 aoa | 20 | 2 as [ 0 é 2 mm a [os | 20 | 2 oe | a1 4 = 85 a) [a | = oe | 3 20 6 2580 wo [os [ae | os | 3 20 oT 260 um | os | 22 | ve oe 7 20 | 156 © 2780 a fo [2 | « 7 ae | 156 a za | ure o 37a B. Electrical Parameters PVC cu Control Cable: Maximum Cond roore% | sopra ormat* Curren Ratinginames Rana caren vo. oe apron cond.Ac. | pesitnce | capectonce MS | netwlnce | teastnce st” |Pepaanee [oactonse {Tits sererat | WiWiORchsvaton | wangon | winnie core | ae nan Stsone | in auton Purpeee_ | Resoce aim _[Tarvore | at0ere | inatn_| microm [Brsand [Out [Ar [round [Buc [ Ar issaton | Ineiton rT ae [| va | om | oz [2 |v[v| » |x|] om | ome [tat es [9a | os | om |e | | wo] |e om | oe pat ee [ose | oso | om |e | | a] | [ome | one =p tat ee [ vse | os | oz fe | | |e |e | oa | oe ota esr van | es | ome er fe fe | | | oes] oe ta ee vse | os | ame [os fs | | we [| ome | 02 rT ee [9a | os | om [fe fw | | |e ome | oe una FS TT eZ eer [9a | es | oe pe pe | | fe oes] oe [ta FT eT as [vse | oso | om [2 | [co |e | | [ome | 02 sof tat ee [ sae | os | om [2 | [| | | | om | oe wpa ee [ 9a | oso] 022 ee [oe [to [ao [oso [tat ae [9a | on | an [wo f+ |» wo | 10 | 026 [oes 2 [ta ae vse | os | oz [9 |e fe] | wo | wo [om | ozs ata ee vse [om [om fe fete|» [> |» | om | oz 20 3 CORE, Al/Cu AS PER IS 7098 P-1 XLPE ARMOURED CABLE Technical Detail For 1.1 KV, 3 Cores Al/ Cu Conductor, XLPE Insulated, Galvanized Steel Strip / Wire Armoured Cables Type / Code Of Cable: A2XFY / 2XFY, A2XWY / 2XWY. As per IS 7098 (P-1) Conductor : Al upto 10 sa.mm conductor are solid class-1 and above 10 sq.mm conductar are stranded compact shaped as per class-215 8130. In copper 4 & 6 sq.mm conductor are solid class-1 class-2 as per IS 8130. 10 class-2, round as per! 8130. Above 10 sq.mm conductor are stranded compacted shaped as per class-2 15 8130, or stranded squmm conductor is stranded Insulation: Crosslinked Polyethylene IXLP Red, Yellow, Bluel, Phase core colors A. Cable Design Parameters Inner Sheath : PVC / PVC tape as per 1S 7098 [P-1 Armouring: Single armouring of Galvanized Steel Strip / Wire, Outer Sheath: PVC Type ST-2 as per IS 5831 FRLS Typel. Option: FR Type Color of Outer Sheath: Black Options: Any other color as per requirement! Neminat “Armouring with at strip APXEVOXFYI ‘Armouring with round wire VA2XWY/2XWY) cross Nominal | Minimor Minimum ‘Approx Net Wr Minimum “Approx Net Wi sana, |, Miimum No.of [Thickness | Thickness | Nomiat|"frey of [Approx | of cane g/km) [Nomina "trea" | Approx. | or nie glk lstrands inconductor| of | ofinner | Thiekot | “outer, | Overall oiameter| ‘outer. | Overat rea nsutaton.| Sheath |Arm.strip] sheath | Dia. At cable [cucable.| orwire | sheath | Dia. [atcabie ou cabe tsqmm) [at [cu | mm | mm | mm | mm | mm | aaxey | oxey | mm | mm | mm | azcwy | 2xWv 4 wo os [| NA | NA [NA [NA | NA | te | 1% | 18 | «90 | 510 é i va | wa | NA [NA [wa [| Wa [ta | 1% [9 [| <0 | oo o 7 7 a7 oa| Wa | WA [Wa [WA | WA | 14 [| iz | = | 0 | 700 5 é é a oa | oe | vo | 1 [mo | v0 [ve | ia | 00 é @ a ca | oe [io | a [oo | wo [te [i | 1750 é é ca | oe | 10 | % [oo | 0 [te | se | 2 70 [1 2 oa | oe | ise | | eso | ao | 20 | ise | a2 3070 a 12 oa [oe | ise [38 | 2100 | ow aE 240 = |e | 6 [0s [08 [im | @ | 20 [| so | 20 [1a | © 30 es | 2 |» 1 os | oe | vee | | ao | coo | 25 | 2m | @ 70 2a fe 7 oe | 08 [so | oo | 2s | 220 | se e270 300 | a0 18 oe | os | 2270 ua0_[_ 10000 236 | 58 1380 200 28 a a0 | 12990, zat | 7) 0 22 or 0a | 2s |e | oa | veo | a2 | 2a | 72 18490 a0 za [or [oe [zee [ m% | eseo [wove | «o | a00 | ar | viez0 | zaseo 21 B. Electrical Parameters Nominal | Mersstnceat” | ‘Resstncest” | grrr, | oePe® current tng oe | tin sorcin | Reasane | Caactance Norma Gurren: ign Amos ser toe Durston “ton Thm ‘hen form | ota WN At ona win cu tond invcanps ep paat se ftom fon | | | | w [7 | [oom | os ofa [aes [se fae [om [oe | oe fo | @ [| a | oo | osm | one ops pra fam pase | ome [oe fo fw fp pm po fo | om pie wpe [ar [ase asa ome [oe [sme some [osee [an [en [ome [oe [oe [ef |e wo fe er sr [ost [ose [ome [ows ome [om [wi [we [im | ue | | oe | routs [ozs [os | a3 [om [oz [ae are | aw [re pe ose [om wom ons [oan | ane [ome [a2 ww [a | wo | 20 | wo [ans | se vo [ oss [ones | oxes [orm | nom [om A va [ ames [ore [ ozs [or [tom [om moan [as aoe [at Da we [ vse Poorer | oz | or | com | om ms_[ a [oss [ow [ee [rae | se ao [ores [are | onee | onme| ome [om | sae [amo [aa | ao | ow | sto | vse | ous soo [ore [aoar [ons [oom | oon [ox | sv am | wi | aw | ow | oo | cna sot [oowes [uosee Pooae [omy [oar [ox [tas eee | seo [ aan [eo [ar ‘ov oowr [oooss [cows [our [ony [ox [sr amo [ra | ow | oe | om | mez | mon eer XLPE Armoured Cable: 22 3.5 CORE, Al/Cu AS PER 1S:7098 P-1 XLPE ARMOURED CABLE Technical Detail For 1.1 KV, 3.5 Cores Al/ Cu Conductor, XLPE Insulated, Galvanized Steel Strip / Wire Armoured Cables Type / Code Of Cable: A2XFY / 2XFY, A2XWY / 2XWY. As per IS 7098 (P-1) Conductor AL class-2, 15 8190. Cu stranded compact shaped conductor as pe Insulation: Crosslinked Polyethylene [ XLPE ] [Phase core color ~ Red, Yellow, Blue] [Neutral care color - Blackl Inner Sheath : PVC / PVC tape as per IS-7098 (P-1] A. Cable Design Parameters Armouring: Single armouring of Galvanized Steel Strip / Wire Outer Sheath: PVC Type ST-2 as por IS 5831 [Option: FR Type FRLS Typel. Color of Outer Sheath: Black (Options: Any other colors as per requirement! tote cu Armouring wih Hat sip (RAKE DXFVT _Arrouring with round wire (ADWH XW caresx | Minimum no, |,Nomina| Minima Nominal [Minimum [Approx] Approx: Net Wi [Nominal [Mirimum [Approx | Approx. Net Wt Sains | Otsirands [Te4res*] THeeress | thick Of | thick. of | Overal | OF able (Kak [Diameter Thickot J overall] of Cable Ka/Km) Neural |_Ineonidetr_|gtason] sheam [AS] Cu.sth | Oi. TaLcabin]ucabie| oFWie | Sein | oie |ALCaBIs | Cu cable samm [Ta [ce] mm | mm frm [ime | aoery | axey_| mm | “mm | mm | aznwr | axwy saeis [we [we [osm [os | os [me [a [ ooo | woo | re | 1a [ a | voe0 | te0s sass | we | we [ovm7 [os | os | 1a | as woof ie | ne [27 [705 [980 casos | ws [ate | rom [os | os [1a | ma oo [1 [vse [a0 | 1500 | aoe sos [ize [ie [aims [ oe | os [ise | 2 sao [20 as_[ a0 _|_se90 assseso [wwe | wwe [ano [oe | os [136 | 3 10020 se_[_ 2500 | exes saaoro [ise | vere [rant [oe [os | 1 | a sioo[ 20 [ze | a2 | ses [5000 paseo frwne| vane [ran] os [oe [om [a ooo [20 [as [as [500 [oro saan [ans | sons [rant [os [os [188 [a7 noo [2s [20 | st | wis | ans aware] ons | suis | i9n2 [os | os [2m | 3 soo [25 [22 [ss | soso [1a axcooriso) suis [| awie [ren | os | os | 22 | 7 vison 25 [228 [eo | coos | 230 aecoo185 | 5300 zona [07 [oe | 252 | w vwsoo [ais 2a [71 | eve | e700 es00-200 | 9300 zany [or [os | 208 | 7 veooo [31s [zee [79 | 90s | ates swuanvano| samo | save [aie | o7 | oa [ 30 | @ nooo | «0 [3 | a8 | twuro | arras 23 B. Electrical Parameters Sue | Max Cond DG | Max Cond. AG | approx | Approx ‘Short Circuit coresx | Resistenceat | Resistance st | geactance | capacitance Normat® Current Rating In Amps. Current Rating Sqm 20"Cin sorcin | “stsone | ofeable {or tse. Duration Neutrt ‘km ‘ake in in Wan AL Con Wah GU Gang inkamps samm [a [ cu | A | co | alm | microuam [Grouna] ouet | Ar |Grouna| Oust | A | AL | ow waste | 12] over | vse | avai | one oz | 5 99 [iz [wo [v5 [235 [ase arasere | vase | onze | vay | own | one | 02 | v6 v7 fs [wo | ves | az | sor sans | over | oser | ose | ous | core | oz | mo | vo | mo | wo | ws | wo | a? | 7a ‘aseso | ane | ova | oars | ome | came | aay | oo | vs | on | o50 | 20 | om | ant | rash saraoe70_| o2sa | oss | ozs | os | oom | oz | zs | vas | ose | as | x0 | soo | vnz0 | 1736 sxisoo70 | 020s | onze | ozs | ones | oor | oz | as | cio | em | oe | 20 | ome | var | 210s saiasrs | one | oor | ozn | orm | oor | a ves | 2s | se | oe | ooo | a | iran | cae sr2aoviz | 0.125 | oars | ae | aor | oar | oor | se | 2 | 0 | a | aso | si0 | vse | oas7 seanoeisy | 01 | oasm | ora | ooe | oan | axa | 370 | aos | om | «so | ovo | s0 | 202 axaoneres | 0077 | ove? | or0z [oose| oo7 | om | «as | aso | s@ | sw | oo | o70 | are ‘xs00e260 | ones | oaass | ooave [one | oor | os | ae | cos | om | soo | con | v0 | ero rua0ea00 | once | ozas | ose [ome | ooo | ose | so | em | 7a | oo | srs | o75 | s922 | v0.07 XLPE Armoured Cable: Crass Sectional View 24 4 CORE, Al/Cu AS PER IS 7098 P-1 XLPE ARMOURED CABLE Technical Detail For 1.1 KV, 4 Cores Al / Cu Conductor, XLPE Insulated, Galvanized Steel Strip / Wire Armoured Cables Type / Code Of Cable: A2XFY / 2XFY, A2XWY / 2XWY. As per |S 7098 [P-1) Conductor : Al upto 10 sq.mm conductor are solid class-1 as per 1S:8190. And above 10 sa.mm conductor are stranded compact shaped as per class-2 IS 8190, In Cu 4 & 6 s9.mm conductor are solid class-1 or stranded class-2 as per IS 8130. 10 sq.mm conductor is stranded class-2,round as per IS 8130. Above 10 sq.mm conductor are stra 158130. 1d compact shaped as per class-2 Insulation: ©: Yellow, Blue, Black) colors - Red, sslinked Polyethylene (XLPE) (Co A. Cable Design Parameters Inner Sheath : PVC/ PVC tape as per 1S 7098 (P-1) Armouring: Single armouring of Galvanized Steel Strip/Wire. Outer Sheath: PVC Type ST-2 as per IS $831 (Option: FR Type/ FRLS Type] Color of Outer Sheath: Black (Options: Any other color as per requirement] “Armouring with at strip (A2XFY/2KY “Armouring with round wire (A2KWY/2XWY1 Nominal | sginimumnor | Naminat | Minimum | Nomina [Minimum] Apprex.| ApproxNet wt | Nominat [Minimum | Apprex.| Approx Net wt erate fran condctr Mictess] Tchress | tye of |THE St |overatt| otcabeKs/km) lDiameter| THRO! |ovra | of able s/km) rue Insstetion| Shearn, [AFm.Strip| spec, | Oia. [ALCable-[cucable.| orwire | sy, | oie, [ALCable[Cu Cable semm [at [cu | mm | mm | mm | mm | mm | aaxey | orev | mm | mm | mm | acnwy| ox é ~ pom fo [os | wa [wa [wa [NA [ WA | te [1m | eat @ Tom [or [os [wa win wa [aD wa De De | 70 0 7 7 a7 | 03 | wa | wa [WA | Wma | NA | 10 a 300 16 @ é a7 ose. va [ 20 | roo | vv00 | 16 z 280 % é é es | soo | 16 26 750 3 @ é oe [os [os [om | ‘zoo [ 16 78 28s o é é wo | os [a 756 [0 00 [16 2 2530 70 z | 2 1 0 0 ise [3 300 | 20 a7 3780 [os [oe 2 [os [os [an [a sao | 20 ma 288 wm [os [oe | os yaa ao [25 7780 ve [| |e a wo [25 | 220 3680 zo fe ae joao [a8 | 206 1985 mm [ss [= | 20 | a7 | os | 2m | m 7000 | 318 7 1900 mo [= | = | 22 | o7 | os | 2m | zoo [a0 oy 2985 @ [Ls |= | 2 | o | oe 2 zoo [an % 30488 25 B, Electrical Parameters ime saegeee | eecete | oe | tm | nents | Se seam | gee | ger SS Set" | ee eee" ee trees Sectional View XLPE Armoured Cable: xe moured cables are widely used as power cables for power transmission in cable duct, power 26 3 CORE, Al/Cu AS PER IS 1556 P-1 PVC ARMOURED CABLE Technical Detail For 1.1 KV, 3 Cores Al/ Cu Conductor, PVC Insulated, Galvanized Steel Strip / Wire Armoured Cables Type / Code Of Cable: AYFY / YFY, AYWY / YWY. As per IS 1554 (P-1] Conductor : Al upto 10 s9.mm conductor are solid class-1 as per 15.8190. And above 10 sq.mm conductor are stranded compact shaped as per class-? IS 8190, In Cu 4 & & squmm conductor are solid class-1 or stranded class-2 as per IS 8130. 10 sq.mm conductor is stranded class-2 round as per IS 8130. Above 10 ‘sq.mm conductor are stranded compacted shaped as per class-2 15.8130, Insulation: PVC Type-A as per 1S:5831. (Option: HR PVC Type -C, 2s per IS $831) ( Phase core colors - Red, Yellow, Bluel. A. Cable Design Parameters Inner Sheath : PVC / PVC tape as per 1S 154 (P-1] Armouring: Single armouring of Galvanized Steet Strip / Wire Outer Sheath: PVC Type ST-1 as perIS 5831 Option: PVC type ST-2 as per IS 5831, FR Type, FRLS Typ Color of Outer Sheath: Black (Options: Any ather color as per requirement] Nominal | yinimum No, | Nominal | Minimum Minimum ‘Approx Net we Minimum ‘Approx Met Wt sSon| (Sree sr] yo, |"S ee reo Som || atn 27 B. Electrical Parameters Nomina Max.cond.D.6. | Max Cond.Ac. | Approx | poprox ‘Short Circuit Resitanceat | Resistance st | peactace | capacitance Normat® Current Rating n Armas Current Raton sectionat |“ z0-Cin vsrcin |More | Serta for tse Duration rea ‘km ‘uke i in With AL Cond With GU Cond inKamps samm [a [cv [A [co | vem | microvam [erouna] duet [ Ar [Grows] owe | ar | Al | ow ‘ = [ear ss | cow [oa [zs [a | w | % | wo | cam | om © [ae [300 [sss [a7 | oom [om |» | o |» | «© |v | w | ase | oa wo [sce [ies [a7 [22 [om [ow [w |» | o [wo |» [2 [om [is ws [at [ais [aa [1se [00 [ow fo [so | | [ [ [im [im 2 12 [ore | rae [oer [oo [oe | m [os | m | [| | 190 | 2a w= | eee [ose [ioe [oes [oom [ous [ve [mm [ee [wo | w [no [20 [aon mo | ous [ores [ose [os [oom [ose | vos | vs | roo [is [wo | tos [ 52 | 05 v [os | ois [oe [oz [oor [oss | ts | wo | iss | a0 [is [ x00 [7m | 109 zo | oass [ores | o2oe [ore | oom [cas | ies [ies [vo [eo [ | a [en | ae wo | 0206 [ares | oz [ores | oom [ows [ae [ve | | em [oa | as | na | vs no [ ona [corse [ oisi [aor | oom [oar | ms | m5 | oma | sos [mos [5s [ 32 | ara soo [01 | oosor [oie [ores [oor [oss [sos | m0 | ais | ses [sss [ ooo [ 228 | mas wo [oor [ou [cover [cose | oor [om | xs | 20 | as | as [so | os [ oon | we soo [oes | o0sss [corey [anor | oor [ovo | a0 | sa | was | eo | so | sw | 90 | ors PVC Armoured Cable ere TT ve and may be revises without prior nformation, 28 PVC ARMOURED CABLE 3.5 CORE, Al/Cu AS PER IS 1554 P-1 Technical Detail For 1.1 KV, 3.5 Cores Al / Cu Conductor, PVC Insulated, Galvanized Steel Strip / Wire - IS 1554 (P-1) Conductor : Al {Cu Stranded compact shaped conductor as per Armouring: Single armouring of Galvanized Steal Strip / Wire class-2, 15 8120. Outer Sheath: PVC Type ST-1 as por IS $831 [Option: PVC type Insulation: PVC Type-A as per IS $831. [Option: HR PVC Type -C. ‘ST-2.as per IS 6831, FR Type, FRLS Typel a per IS 5831] [Phase core colors - Red, Yellow, Blue} ( Neutral core color Black) Color of Outer Sheath: Black (Options: Any other color as per requirement! Inner Sheath : PYC / PVC tape as per IS 1554 (P- A. Cable Design Parameters ‘Aremouring with Nat arp INFYINFY) ‘Armouring with round wire [AYWYTYWY Size Nominal | Minimum Minima Minimum Coresx | MinimumNo. |rpickness| Thickness | Nominat | Thick of [Approx.| APPFOKNetwt | Nominal] Thick ot [Approx | _ APBTOX Net wt Samm | of strands of | atinner, | Thick of | outer. [overatt LofCable Ka/Km) |oisreter] “outer. | overall | OFC IKe/Km) Neutrat | inconductor_Ineutaton) Sheath, [arm.Strip| Sheath | oa. [aicable[cucabie.| ofwire | sneatn | oie. [atcable, cu cade Samm [ar [cu mm | mm | mm | mm | mm | avy | YY | mm | mm | mm | avwy | yw sais [we [we [iano] os [os [vo [ m iso | te | 1a | | vee ws_[ se [iano | os [os 26 wso | 1s | 140 a | 42s ws_[ se [ana [os [08 30 zoo [18 [a] es sxrons | raie_| tae [tana | 04 | oe 3 0 [2 36 | za] 780 35000 | tei | ise | iaia | 04 | 08 a re 7z_| 39 | 2960 | van smizo-io [asa [vane [rana | os [08 a sis [2 |_| 2480 | oon seisoo7o [asia [ra [rena | os [08 s woo | 2 | sae [a | avo anase5 | sons [sons [aus [os | oa a moo_| 25 | 200 | so | sis sxzaoerz0| sone | aene [ozone] 04 | 08 S voooo | 2s | 200 | sa | oes sono] sos | suns [aaa | 04 | 08 a vzao0 [315 [252 | os | oie sxaoovras| sars0 | sarso_[ 20/2. > | 08 | 20 [w seoo [315 | 24a | 75 | 900s, ov2u0| saia0 [sara | son2[ or [oa | 28 | 7 eso |< | 300 | ac | rasao sweo | sux [oaao] o7 | oa | 300 | a sooo | «| 300 | 92 | 1sva0 29 B. Electrical Parameters sue | Maxcconé.0.0. | Max cond. ac. | Appr” | approx ‘Shor Cireuit come | Mame | Magara | ezine | ann Normat® Current Rating In Amps Case ating Nena ‘km ‘ken * : Wiha Cond With Gu Cond inks samm [A | cu] Al | Go| km | mierotmm [Grouna] Oue | Ar |Grouna[ Ove | Ae | Al | cw ass | 12 [orem | ia | oar | oo | oa | 7» | & | mo | o |e | v0 | 19 | 208 arabes | nase | ose | toe | cas | ooee | om | o | 7 |e | va | oe | 110 | 20s | «oa sess | oaer | oser | ore | ome | ace | 047 0 [| ios [vs [es [ss [30 [ors aeons | oui | oxen | oss | osm | oom | ose | vos | vs | v0 | ws | wo | 6s | soa | eos axvs50_| ose | 0.3 | ose | axe | oars | ose | ves | io | 155 | 2 | vs | 200 | 72 | 109 sxrzo70 | 0253 | onss | oso | one | oars | os | 95 | vs | veo | zo | we | 20 | 902 | 138 setso70_| 0205 | cree | one7 [oes] oom | os | 210 | 15 | aos | 2m | ms | 26s | via | 173 seta5v95 | one | oow | ore [omer] oom | os | 2s | zoo | ao | soo | ms | sos | var | 213 seso0ers0 | 01 | aos | 0122 | oorss| oora | ose | sos | zoo | ais | aes | sas | «oo | 28 | aas secoonres | o77e | one | o0v6t | oose | oom | a7 | 05 | om | ame | us | su | a5 | oom | coo axs00-240_| 060s | o03ss | aoree | avs | oor | o70 | 370 | sa | «as | am | a | sw | soo | srs axes0es00 [ones [oozes | one | onses [oor | ovo | «> | aso | ao | ss | om | os | azp | ras PVC Armoured Cable: PVC Armoured cables are widely used o supply energy in indoor tor any underground instalatins. They ae used in tte wtng, underground wting and industri Craze Sectional View 30 4 CORE, Al/Cu AS PER IS 1854 P-1 PVC ARMOURED CABLE Technical Detail For 1.1 KV, 4 Cores Al/ Cu Conductor, PVC Insulated, Galvanized Steel Strip/Wire Armoured Cables Type / Code Of Cable: AYFY / YFY, AYWY / YWY. As per IS 1554 (P-1] Conductor : Al upto 10 sq.mm conductor are solid class-1 as per 15:8130. And above 10 s9.mm cond Fare stranded comp: shaped as per class-2 IS 8130, In Cu 4 & 6 s9.mm conductor are solid class-1 or stranded class-2 as per IS 8130. conductor 10 sqmm 's stranded class-2 round as per 1S 8130. Above 10 squmm conductor are stranded compacted shaped class-2 as per 158130 Insulation: PVC TYPE-A as per IS 5831. (Option: PVC TYPE - Cas per IS $831) (Core color - Red, Yellow, Blue, Black) A, Cable Design Parameters Inner Sheath : PVC / PVC tape as per IS 1554 [P-1] Armouring: Single armouring of Galvanized Steel Strip / Wire. Outer Sheath: PVC Type ST-1 as per IS 5831 Option: PVC TYPE - ST-2 as per 15 $831, FR Type, FRLS Typel. Color of Outer Sheath: Black [Options: Any other color as per requirement! Se | meimonne.o Me™ | Rest] Nanas ft oes | eigen [Noni ee [re | ofa ge 31 B. Electrical Parameters Nominat | MaxCond DC | Max cond AC | APPT | ayprox Normol® Curent Rating In Amps Short Circuit roms | Retitanceat | Resistanceat | negrance|capostance -—Gares 1 Current Rating Pia 20"Cin esrcin | Merson | spectre {or tse, Duration ‘en ‘ke ‘dk ” inkamps samm | A | | A [| ce | km | microvk Groune| oust | Air | orouna | ouct | air | al | co 4 =| sar sss | oo | om | @ | a | a | % | » | a | vom | ous é aa | ace | sm | a7 | oom | oo | o | o | © | o | a | oass | oa 0 300 [va | a7 [22 [oon | om | « |» | o | | » | [ow [is 16 wi pus | 2 [ise | ome | oo | «| o | | | | « |i | ie 2 v2_[ or | tas | oar | oo | ox | 7 | « | mo | |e | v0 | 190 | 202 | oases | ose | ice | om | oom | om | 2 | 7 |e | vo | o | 10 | 206 | coo | os | oser | ore | ome | 00s | oav o | = | a | we | va | ms | se | ae % az | cava | ase [ave | oom | ose | ves | 1a | vss | ow | vs | ooo | 722 | 109 vo | os | oss | os | ove | oom | oa | ves | vos | veo | 20 | vos | a0 | ox | ro@ wo | 020 | oz | 027 [ore] oom | om | 20 | vs | mo | 2m | za | 2 | ua | va vas | 01 [oom | oa fone | oom | om | ms | 20 | mo | ooo | as | oo | ar | ma 200 or | nos | oreo [oars | oar | ase | wos | 200 | ais | as | os | ao | me | ms zoo core | oos7 | oover | ose | oom | aro | ss | 2m | sms | as | a0 | os | aos | sov | o0e0s | none | oorse [oo | oom | aro | so | azo | «as | em | a | sao | cao | ors woo onser | oozes | one; [oon | oom | aro | a | soo | oo | os | a | om | ox | res PVC Armoured Cable: These power cables fr energy supaly re instaled outdoors. in wate, are largely use in Fe wiring, underground wiring a wel a industrial contra wiring le ducts, omer stations i 4s and in subscriber networks, where mechanical damages are not tobe expected, Thy 32 3 CORE, Al/Cu AS PER IS 7098 P-1 XLPE UNARMOURED CABLE Technical Detail For 1.1 KV, 3 Cores Al / Cu Conductor, XLPE Insulated, Unarmoured Cables Type / Code Of Cable: A2XY / 2XY. As per IS 7098 [P-1). Conductor : Al upto 10 sq.mm conductor are solid class-1 as per 15:8130, And above 10 sa.mm conductor are stranded compact shaped as per class-2 1S 8130, In Cu 4 & 6 s9.mm conductor are solid class-1 or stranded class-2 as per IS 8190. 10 sq.mm cor is straned class-2 round as per IS 8130. Above 10 Inductor are stranded compact shaped as per class: Inner Sheath : PVC / PVC tape as per 1S 7098 [P-1). Outer Sheath: PVC Type ST-2 as per IS 5831 [ FRLS Typel ion: FR Type / Color of Outer Sheath: Black tions: Any other color as per requiremen Insulation: Crosslinked Polyethylene (XLPE] [Core color ~ Red Yellow, Blue) A. Cable Design Parameters Neminat Cross | Minimum No, of Nominat Minimum Nominat Approx. ‘Approx, Net wt Of Cable Kg/Km] Sectional | Strands inconductor | Thickness | Thickness ot | Thickness of overall ‘area of ineutation | InnerSheatn | Outer Sneath Diameter cable. cu cable. “ z td o7 a3 1S 1% 70 20 z 1 td 7 03 15 1% 700 x 0 7 o7 a3 18 18 250 0 16 é é oF 03 18 18 a0 “ Fy é é oF a2 2 570 Ta 30 é é 1 a2 A 720 1590 7 2 2 Fl 04 2 950 2200 % = 5 ua m7 22 a 1250 2780 180 5 8 1 as 2a w 7 7550 185 2 Ey 1 as 2a a zi 3700 2 a 3 1 m7 28 @ a0 7390 300 0 18 06 20 = 3600 7190 00 a 20 a7 a2 a 1560 7 Ey s 22 a7 2e ry 70 1940 0 a Be a7 38 B 70 923 33 B. Electrical Parameters Nominat | "etcstnceat | 'Resstencest | gtP0%, | Aopen current ating sce, | aoeln povcin | esetanes | apactance Norma Gurren ating nos fertoce Dustin on ne cnn Soh | ote WN Acne vn cu cond inwanos sam [A [apm [ee] atm | miro [rauna] pact [ar [ores] ove [ae [a [ oo aa so [tom [on | | | wo | w | |» | oom | or saa pace ee fae [ooo fon ps fo | ps | | | ose | cose wp oe [is [sm pase | oe [oe [a pe fs [mp fon [ie oi po pew fie | ome [oe [oe fo fo fe mf foe pn Spas pase Do peat [ome pe po ae oi oe poet [oar [ose [oe [owes ome [oe | [nf we [om [ws [wo | ore | ref ows [ane [osm [os [oa [ze [aif ote | aw [me | oe | see | [om [om [oan [one [ome [om [om [we [er | am | aw | a | ee [ar vo [oma foxes [ome [over | nom [aa |e | es [mee | ves | ao [mo [nae | ote vf ozee [ove [ozs [arse [aon [aay Pas [ao [ae [as | ao as Pa | 2s re ores Loom [er Lore | aon [aay as [as [say Dass [aeons ara [2a aa ores [arse [ oer [oome| ome [on | sve [om [ae | ao | ow | so | mse | so sot] ore [assor [oso [omme| om [om | so os [at | wo | ow | ow | mao | co ‘oo [oor | coer [ure [ome| on [om | a [oo | oa | om | ao | om | sve | ore sat oowy [novas Paawee [omar [omy [xe [sar Damp | a [De [ooze [oa XLPE Unarmoured Cable: ALPE Unarmoure cables are used te supply energy tor underground installation inwater, power stations, wall as in dsribution boards. They are also used in subscriber networks, where 34 3.5 CORE, Al/Cu AS PER IS 7098 P-1 XLPE UNARMOURED CABLE Technical Detail For 1.1 KV, 3.5 Cores Al/ Cu Conductor, XLPE Insulated, Unarmoured Cables Type / Code Of Cable: A2XY / 2XY as per IS 7098 (P-1). Conductor + Al / Cu Stranded compact shaped conductor as per class-2, 15 8130. Outer Sheath: PVC Type ST-2 as per IS $831 [Option: FR Type FRLS Typel Insulation: Crosslinked Polyethylene { XLPE | [Phase core calors- Color of Outer Sheath: Black (Options: Any other color as per Red, Yellow, Bluel [Neutral core color Black! requirement Inner Sheath : PVC / PVC tape as per IS 7098 [1 ‘A, Cable Design Parameters Si coreex Nomina | — Minimum Nominat Aoprox Approx. Net wt OF Cable Kg/Km } Sqmm= | _ Minimum Ne.ct | thickness | Thickness | Thickness Overall Neutrat [Stands inconductor | ofinstation | otInerSheath | efter Sheath | Olmeter ‘ALcable. cu cable. samm [at cu mm mm mm mm noxr ry sizes | ws |W osi07 a 2 @ Ts sass | _oe | #6 o9i07 a 20 2 15 anos | ols | w6 10109 a 20 a 7980 e736 126 107 a 22 FN 2680 195050 16 1a Oe 22 ae 258 3et20070 wane 12ha oe 22 EY 80 3150070 wera a 2a 6 BBS 3185095 aons_|__ tana a5 26 % aes Be2W0r120 suns | 1na a 2a @ 78 1a00075 wane | vane Oe 20 7 80 vo7e0 c00+185 sao 20/6 a7 Be 6 5580 13980 335000240, 22nT oF 3a 7 om 1 x63 268 a7 20 @ 2885 21970 35 B. Electrical Parameters a re er Shor Great carrx | essaneeat | Restncest | Reson | eapctnee ama Current atg a rps aren ating Sem ison | “eran samme | ahem ‘hen | WN Alcona win cu Cond iavamps Semn [a [wf a [ae] ohm | mera [orana] oo | ar [aroma] ove | ar [a [on wae [12 form [ ise fom [om [om | | |» | mm | mo | im [om | aan sass | Goat Pose [on [osm | oo [oases |e [ot [sro ss ar [sn sane [asa [ose [eae | ous | core [ome ue [oes [ea sass | ous [ozs | os [oa [com [om [ro | wo | me [vo [me oe [ese | anon aso [ose ors | owt | ome | com [om [zoo | ves [om | ao 20 | ao [evs | roan wraro [oe [ass [ose [om [oom [om [am [ie | ae | om | 20 | avo | nae | re nr0595 [one [ooo Dart Dorr [eam | om [ess [| sn 79 268 aioe | ores [ours | ore [one [oom [oar | se | mmo | a | wo | om | so | ome | suse saree [01 [oc | ais [ome | oon | on | ao | sos | wt | wo | om | om | a | ae saroies [oor | ace [ones fooe| oo [on [ws | wo | sa | sm | ao | om [ave | rz suasoaca [aowr [mas [cases Losier [onur [ ose [sn [ aro | ra | ooo [ate | ors | aoe | oom cross Secon ew XLPE Unarmoured cable 36 4 CORE, Al/Cu AS PER IS 7098 P-1 XLPE UNARMOURED CABLE Technical Detail For 1.1 KV, 4 Cores Al / Cu Conductor, XLPE Insulated, Unarmoured Cables Type / Code of Cabl : A2XY / 2XY as per IS 7098 (P-1] Conductor :Al upto 10 sa.mm conductor are solid class-1 as per IS 8130. And above 10 sqmm conductor are stranded compact shaped as per class-2 IS 8190. In Cu 4 & 6 s9.mm conductor are solid class-1 or stranded class-2 as per IS 8190. 10 sqmm conductor is straned class-2 round as per IS 8190. Above 10 sqmm conductor are stranded Is 2130 compact shaped as per class-2 Insulation: Crosslinked Polyethylene [XLPE) (Core colors - Red Yellow, Blue, Blackl A Cable Design Parameters Inner Sheath : PVC / PVE tape as per IS 7098 [P-1) Outer Sheath: PVC Type ST-2 as per IS 5831 (0; FRLS Typel. lion: FR Type J Color of Outer Sheath: Black [Options: Any other color as per requirement! Grose | _ Minimum No.of Nominat Minimum Nominat Approx. ‘Approx, Netw of Cable [Kg/Km) Sanm | Standsinconductor | thickness | Thekness | TWekness ‘overall Newt cflneuiation | oftanerSheatn | of Outer Sheath | Diameter Newbie. Gu Coble samm [al ca mm mm =m mm eu 2x 4 Wi a7 1 7 260 300 é 7 wr a7 18 © aut 280 16 @ é a7 1 20 zat % é o a 2 2 a 3 é é a9 20 26 Tat 0 é é 10 20 a 785 % 5 5 1 22 a 685 20 5 18 12 Be a 225 50 5 18 1 2 S 268 5 A 16 28 30 00 200 2 a 7 30 5 080 300 2 3 18 32 @ 5020 00 = = 20 36 70 85 500 = @ 22 38 a 7780 0 2 © 2 40 ny 785 37 B. Electrical Parameters bueto XLPE Unarmoured Cable: hemials and ether seven ne XLPE Cu conrl cables canbe used in severe working temperature condtons They are also suitable or use nd wet rooms. Incas of outdoors they cn be used any with Uvpratctio, 38 PVC UNARMOURED CABLE 3 CORE, Al/Cu AS PER IS 1554 P-1 Technical Detail For 1.1 KV, 3 Cores Al / Cu Conductor, PVC Insulated, Unarmoured Cables Type / Code Of Cable: AYY/ YY as per IS 1554 (P-1) Conductor + Al upto 15:8130, And above shaped as per clas: solid class-1 or stranded class-2 as per IS 8130. 10 sq.mm condi conductor is stranded class-2 Is e130 Insulation: PVC TYPE - A as per IS 5831. [Option: HR PVC TYPE - C, 10 sa.mm conductar are solid class~ tor are stranded compact as per IS 5831] [Core color - Red, Yellow, Blue ‘A. Cable Design Parameters 215 8130. In Cu 4 & 6 sq.mm conductor are 10 sq.mm round as per IS 8130, Above 10 squmm conductor are stranded compact shaped as per class-2 Inner Sheath : PVC / PVE tape as per IS 1554 [P-1) Outer Sheath: PVC Type ST-1 as per IS 9831 (Option: PVC TYPE- ST-2as per 1S $831, FR Type / FRLS Type. Color of Outer Sheath: Black Options: Any other color as per requirement! 39 B. Electrical Parameters Nomina) Mae Cond. 0. | Max Cond AG. | Avprox | Approx Shor cient Cross | Resistanceat | Resistance at | Reactance | capacitance Current Rating Sectienat z0°cin esrcin | atone | etecabie Normat® Current Rating In Amps for tuee- Duration "hres ‘alk ‘km in in Wan Alone With Gu Cand inkamps semm [a [ ca | A | Go| arm | microwam [Ground] Ouet | Ar [Ground] Duet | Ar | A | ou 4 ae | - [ss | coe | om | | = | = | «% | 2 | 2 | osm | xe @ wa a0e | ess | a7 | cove | oe | os | o | | = | | o | oss | oo 0 aoe | ies | a7 | 22 | 00m om | « |» | | o | 0 | 2 | ov | ii a 12 [om [im [oe | oom | oa | ~ | «a ||» | | 0 | 190 | 200 35 | oeee | osm | vor | om | oo | ove | ve | 7 |e» | vo | o | 10 | 2m | amo so | ose | oer | aver | once | oom | ove | no | 95 | vos | vs | ize | vas | sa | oro ma | oes | ozee | ose | onze | oom | ove | ia | 1s | 10 | ve | vo | vos | ose | o05 vo | azss [oss | one | ore | aovs [oan | vas | ves | rao | mo | es | mo | oa | rae veo | oz06 | osm | oz? [ores | oom | cas | 20 | 175 | 205 | 270 | os | ms | va | v73 ves [ones [oon | or [ones] oom | oa | m5 | moo | 20 | 200 | oss | aos | tar | za zo | ones | oorse | ons |oon2] oom | oa | 2 | zm» | 20 | oo | ov | oss | 102 | 216 wo | corm | oo | cove | cose | oor | o70 | xs | om | as | ws | xo | as | oa | soo | oce0s | onxee | corse [ose | oor | ov | a0 | 20 | «a | oo | oo | sw | ceo | ors ao ecu [oozes | acer Looe | oom | or | «os | 200 | ao | os | oo | os | x9 | 5 PVC Unarmoured Cable: 40 3.5 CORE, Al/Cu AS PER IS:1556 P-1 PVC UNARMOURED CABLE Technical detail For 1.1 KV, 3.5 Cores AL/ Cu Conductor, PVC Insulated, Unarmoured Cables Type / Code Of Cable: AYY / YY as per IS 1554 (P-1) Conductor: Al class-2, 15 8120. Cu Stranded compact shaped conductor as per Insulation: PVC Type-A.as per IS 5831. (Option: HR PVC Type -C, as, per IS $831) [Phase core colors - Red, Yellow, Blue] [Neutral core color Black} A. Cable Design Parameters Inner Sheath : PVC / PVC tape as per 15 1854 [P-1 Outer Sheath: PVC Type ST-1 as per IS 5831 (Option: PVE type ST- as per IS 5831 / FR Type / FRLS Typel. Color of Outer Sheath: Black [Options: Any other color as per requirement! cae Somme | _Mnmomne.ot | thames | thetness | thcmess eral “eorex Netwsst cai naren) Neural | stvandsimconductor | fission otlnnerSheatn | cfGuterSheath | Diameter Wome Cray Summ [ a] ee vm vm om ‘vm ae wane [ss [ae | vara 08 20 2 0 sane | oe | we [tana 03 20 2% 0 3005 a 2 20 a on a5 ae [van 04 22 2 1280 55 6 | 1a 34 22 % 2120670 vai [ tara 5 26 @ 50670 wit 18a 085 26 « Be aaa [2200 26 a0 = 2 sata | 2a 06 3a @ 2 sano | 2n0 an ri @ 6 sabe z or ae 7 41 B. Electrical Parameters sue | Marcond.oc. | Wax cord.ac. | Approx Short rut fee stance sistance Reactnce Normal® Curent Rating In Amps for toes ona om ‘kn ‘ok . Walon With ov ond inkampe samm [Aw [| @ | m | @ | mm | orwna | out [ar | orem | oot [ar | wm | waste [12 [oni [ia [oar [oom | m~ [| | m | = [| | wo | ino | ae waste | nee [ osee | te [aa [one [| m | w | vo [| vo [ 20s | aco xaos | owt [oar | aren | ease [oom [vio [os | ws | ves [ ves | 0s [a0 [7 auoas | ous oa | asse | asm [00m [ras | ae | an | 195 [| tos [52] 0 asco | om [osm | ese [cae [oom [ves [vo | v5 | a [175 | 200 | 722 | 109 ea0.r0 | aas | ossa| oae | eree | ors | ves | v5 | tao | 20 | 105 | mo | a | wee aeis070 [azo | osee | oz | aves [core | zo [ws | aos [xo [vas mes | na | ora awiesive | area | oomi [on | one | oom [25 | 200 | oo | aw | os | ow [ur | aia aauoriaa | ones [oor [wisi [aoe [oom [2s | 28 | an | ses [| aes 0 araentse | as [oom [area | -aarea | oars [205 | [an] as [as | coo | roe xuoo-tas | oam@ | o0cr [eanei | cose [aon [xs | om | om | aos | ao | cs | cou | ceo zxs06-200 | oats [ oonee [omer | cae [aon | om | ae | es | «mo | a | so | seo | 75 zxa20.00 [osuv | oozes | asi | aoe | aon | wos | a0 | en | sss | oo | os | oo | mas PVC Unarmoured Cable: 42 4 CORE, Al/ CU AS PER IS 1554 P-1 PVC UNARMOURED CABLE Technical detail For 1.1 KV, 4 Cores Al/ Cu Conductor, PVC Insulated, Unarmoured Cables Type / Code Of Cable: AYY/ YY as per IS 1554 (P-1) Conductor : Al up to 10 sq.mm conductor are solid elass-1 as per 1S 8130, And above 10 sqmm conductor are stranded compact shaped as per class-2 IS 8190. In Cu 4 & 6 s9.mm conductor are solid class-1 or stranded class-2 as per IS 8130. 10 sqmm conductor is stranded class-2 round as per 1S 8130. Above 10 sq.mm conductor are stranded compact shaped as per class-2 15.8190. A, Cable Design Parameters Insulation: PVC TYPE - A as per IS $831.(Option «HR PVC TYP! as per IS $831] (Core colors - Red, Yellow, Blue, Black} Inner Sheath : PVC / PVC tape as por IS 1854 [P-1] Outer Sheath: PVC Type ST-1 as per IS $831 [Option: PVC TYPE- ‘ST-2as per IS 6831, FR Type / FRLS Typel Color of Outer Sheath: Black Options: Any other color as per cross | Minimum v.01 | Nomint | minum | Nomina opto Approx. Net of Cable K/Kn) secionat | siransinconductor | Thikness | Thexnest | Therese overs sanm_ [A] nm om on a vw oi 7 12 18 16 20 a0 ‘ 1 18 18 e 20 0 6 0 z 12 20 2 0 9 Fa n z 2 20 % 70 rE 3 ‘ 6 12 20 20 5 ¥ 0 ‘ é 1a 22 2m 20 2480 5 a 16 2 @ 2000 a5 0 = > 6 08 2 w Eg ma a LY 2 26 a 2 2 | = 20 28 5 2490 e200 Er A 22 n © 580 10500 0 3% 2a 3 @ aso a) ae za ae 7 16700 = | 8 “0 @ 20980 = | = 3A “a % 10700 2960 43 B. Electrical Parameters crs. | ‘Mewes | "Reames [ett pte] nama etn ne Sea PVC Unarmoured Cable: 44 Design: We offer an assortment af silicon rubber cables which have been ruggedly tested for their durability and reliable perfor- mance. The entire assortment is fabricated using optimum quality silicon rubber and offered in conformance with various speciica- tions. Moreover, we also have the ability to customize our assortment as per the specification detailed by the clients. Conforming Standards: IS 9968 P-185 4007 Table 8 & table 10 85:6195, DIN VDE 0282-7, Operating Temperature: The cables are flexible and it can be retained over wide range of temparature [-60°C TO +180°C} Silicon Rubber Cables: SILICON RUBBER CABLES Salient Features : = high temperature operation - excellent electrical properties = moisture abrasion resistant = long service life + light weight and good anti friction properties = flexblity over wide range of temperature «high thermal conductivity «resistance te ozone and sunlight Products: 0.5 to é mm’ all colors 10 to 50 mm? White or Black, other colors on request seperating tape on core for cross sections 10, mm! and above Packaging: Rolls, spools Working Voltage cls «10 mm? 450/750 cfs> 10 mm? 609/ 1000¥ The silicon rubber insulated cables are used in the generation and transmission of electricity. When exposed to fire, the silicon offers circuit integrity, low smoke evolution and freedom halogen acids ear and Thermal stations and also in airport i paper and pulp industries, Ni ‘Table 1: Cable with silicon rubber insulationl/S 968 Part 1 They are commonly used in steel mills, petrochemical industries, hting, Table 2:Cable with Silicon cubber insulation with reinforcing braid of Polyester Yarn / Glass Fibre vow create | Nencamssa> | emer rogeeeeraenesc|nonasraany | woe 45 WELDING CABLE The cable has high flexibility subjected to light, ozone, oxygen inert gas, and cl, and itis also resistant to the effects of cold, heat, and fire. Suitable for use in open air, in dry as well as damp interi- ars, The high degree of flexibility does not form knots on the cable which could lead to intornal break of conductors. Minimum Bending Radius: 5X cable diameter ‘Temperature Range: -20°C to +80°C Welding cables: Cable Construction Super find strands of plain Copper with single elastomeric insula- tion. Type SE 1 Conforming to the requirements of IS 6280-1984, Test Voltage: 1000V Specification: 1s 9857-1990, IS 6980:1984, IS 8130:1984 In welding cable, a highly flexible Elastomeric PVC jacket surrounds fully annealed rope-stranded bare copper. The insulated flexible cables are used to connect welding machines. he heavy duty welding caale is resistant to flame, oil, abrasions, tar and grease. No.of Cores:x Nominat Nominal Cross Max Strand Max. CR (Spec! Insulation "Nominal Cable Diameter mm Sectional Area tm Diameter [mm ‘km Thickness mm 1% 021 1 200 we @ 02 078 200 109 0 a3 oa86 220 2 0 oz 20 Tee % 031 0206 20 ree ‘The conductor construction given above is indicative and will comply for conductor diameter and resistance as per IS : 8130-1984 No.of Cores x Sectional Area (mm) ‘Current Rating of General Service Normal Duly Elastamerie Compound Covered Cable with Copper Conductor ‘current Rating ata Maximum Duty Cycle of 0% ee wo a0 20% [a a z B a a 6 % i 12 a0 15 1 ei 228 7 3 156 168 21 285 a 30 7 2 i 360 a0 70 2a 269 320 158 8 % 29 3 386 3b “ Ambient air temperature = 30°C Maximum conductor temperature 60°C 46 SUBMERSIBLE CABLES 15 694 1990 RR Kabel Shramik brand of flat cables are manufactured with rigid manufacturing controls to sustain complete immersion in water, protection against rain water, The conductors are uniformly drawn from high purity electrolytic grade copper on high precision drawing machines with superb flexibility. Compactly bunched to offer uniform reistance across all conductors extruded on dual screw extrusion machines with inline monitoring of cable diameter and high voltage spark testing, Finally, sheathed with abrasion resistant PVC compoud impervious to oil, grease and wat Conductor: Annealed plain copper to 1S 8130, uniformly bunched Sheath: Type ST1, 1S $831, with excellent water resistant to forma circular shape properties. Insulation: Type A, 1S 6831, with very high insulation resistance under damp conditions. ‘Submersible Flat Cable: The submersible flat cables are mainly used in pump connection, Though they are mainly used to supply power to purnps, they are also used in industrial applications. These cables are specially manufactured keeping in mind the severe, tough and difficult conditions in which they RR KABEL SHRAMIK ~3 Core Flat Cables {as per IS 694 1990 -ISI marked } Conan Trawaton Sheath Brera aimensone conductor reainom) | woidanct | Tekness Sie apron) Resetance curren carrying Senn ssrandemm | (Nomi Wwxtinm | @20%c Mast aen eapacsy 60°C kgs A wa ow Tax s20 A m7 as san ar i Taa0K620 Ta z “0 03 08 12 1607.0 5, a eo eo os 12 1.09800 2a) a wars 1a 12 BeSOKS0 7 = 160 6/04 19 1 Fas0X 11.00 1 a 250 60a 12 1s Baxtia 6 ao Bate 12 1 EGO Toa 77 = eas te 7 WNT 5 Note : insulation thicknes, sheath thickness and overall dimensions given in ths table are nominal values. The conductor is designed to satisy the regurement of conductor resietance apr IS #120 1986 RR KABEL SHRAMIK ~3 Core Flat Cables { generally conforming to IS: 694 1990) Conaucor Testo Sheath Breall mensions conductor reattiom) | Noida.ot | theaness [Thexness | Size approx! Resistance current carrying Serm | stranaemm | tNomimm | Inomimm | IWxTImm | 20° (Max) ahem Copsey 80°C Ape 1S BS tH z TAOS Ta % 25 aus or 5 mio xaTs 7a 2. “0 ssl oe é 60X75 a9 B eo eas GE 7 ia10K8. = Ea o a 2 7 50x95 1a = 160 fe 0 q 75.90%31.0 1a e Note: The overall dimension exceed the maximum requirement stated ns 694 1990 47 1 RAMRATNA G R oO oU P RR KABEL LIMITED Regd. Offi Ram Ratna House, Oasis Complex, Pandurang Budhkar Marg, Werli, Mumbai - 400 013. India Tel +91-22-2676 9009 / 2692 4146 © Faxt 2491 2586, E-mail: rrkabel(@ramratna.com Corp. Offic 305/A, Windsor Plaza, R. C, Dutt Road, Alkapuri Vadodara - 390 007. Gujarat, India Tol 491-265-232 1891/2/9 + Fax: 292 1994, E-mail: vadodaraléramratna.com ‘Ahmedabad: 079-6605 47 06, Bengaluru: 080-4204 3634/35, Bhubaneshwar: 0674-2595 957, 14-2436 37 26, Coimbatore: 0422-2910 560, Jaipur: 0141-2363 527, Jalandhar: 9357 325 100, Kochi: 0484-2378 782, Kolkata: (33-3251 52 53, 033-2217 80 78, Lucknow: 0522-6113 745 /46, Madurai: 0452-3209 460, Mangalore: 0824-2458 584, New Dethi: 011- 4303 83 95/2735 54 77 / 78, Pune:020-2567 7207, Rajkot: 07327 72250", ‘Secunderabad: 040-2780 40 98, Silvassa: 0260-2641 333, Surat: 09975951 000. Chennai: www.rrkabel.com www.ramratna.com con

Vous aimerez peut-être aussi