Vous êtes sur la page 1sur 40

ABB Oy Distribution Automation

Event List for RET 545

Document ID:
Revision:
Description:

1MRS755227
A
RET 545 A 4.36

SW build:
SW revision:
BIO1 version:
BIO2 version:
PS2 version:
MIMIC version:
MIP version:
GAL CPU1D301 version:
GAL CPU1D102 version:
GAL CPU1D305 version:
DSP version:
RECAP pvcs label:
Language version:

4.36
A
118001 / Rev F sw build 2.08
118002 / Rev F sw build 2.08
118004 / Rev D sw build 2.07
118005 / Rev E sw build 1.15
118020 / MIP50E
118019 / Rev C
118025 / Rev C
118026 / Rev E
RB_RET54XDSP_3.13
RB_INHOUSE_RET_4.30
WB_CODEFILE_ALL_4.34.01

Note! This list covers the maximum set of cards and corresponds to the
functionality level M (Multi), including all optional functions.

January 20 2005

ABB Oy Distribution Automation

Event List for RET 545

Channel
/* JMAA-38R000 / Rev D CH000

Code

Values

/* JMAA-38R002 / Rev C CH002

/* PS2 / Rev B PS2

Default

IEC address

GI Table

E48
E50
E51
E56
E57
E59

EV_INT16
EV_NODAT
EV_NODAT
EV_32BIT_
EV_32BIT_
EV_NODAT
Default ma

65536
262144
524288
16777216
33554432
134217728
185401344

1
1
1
1
1
1

24
25
26
27
27
28

1 E0
1 E1

EV_NODAT
EV_NODAT
Default ma

1
2
3

1
1

0
0

2
2
2
2
2

E0
E1
E2
E4
E5

EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_1BIT
EV_1BIT
Default ma

1
2
4
16
32
55

1
1
1
1
1

14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11
E12
E13
E14
E15
E16
E17
E18
E19
E20
E21
E22
E23

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT

1
2
4
8
16
32
64
128
256
512
1024
2048
4096
8192
16384
32768
65536
131072
262144
524288
1048576
2097152
4194304
8388608

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

DB name Event State Event Reason

RX

Scada address

*/
0
0
0
0
0
0

/* JMAA-38R001 / Rev H CH001

Weighting coefficient

January 20 2005

0
0
0
1
0
0

F001V015
F001V015
-

Error
Startup
Overflow
Deactivated
Activated
-

Analog configuraALA
Module
CMS
Event buffer
ALA
IRF error
INS
IRF error
INS
Watchdog error ALA

2024
2025
2026
2027
2027
2028

00-

OFF
ON

Test mode
Test mode

INS
INS

2100
2100

0
0
0
1
1

1
0
0
1
0

F002V005
F002V005
F002V005
F002V004
F002V004

Disable
Local
Remote
Inactive
Active

Recent control p LRS


Recent control p LRS
Recent control p LRS
Interlocking bypaINH
Interlocking bypaINH

2200
2200
2200
2201
2201

1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12

1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0

F014I001
F014I001
F014I002
F014I002
F014I003
F014I003
F014I004
F014I004
F014O001
F014O001
F014O002
F014O002
F014O003
F014O003
F014O004
F014O004
F014O005
F014O005
F014O006
F014O006
F014O007
F014O007
F014O008
F014O008

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated

TCS 1
TCS 1
TCS 2
TCS 2
OVtemp
OVtemp
ACfail
ACfail
Binary output 1
Binary output 1
Binary output 2
Binary output 2
Binary output 3
Binary output 3
Binary output 4
Binary output 4
Binary output 5
Binary output 5
Binary output 6
Binary output 6
Binary output 7
Binary output 7
Binary output 8
Binary output 8

3401
3401
3402
3402
3403
3403
3404
3404
3405
3405
3406
3406
3407
3407
3408
3408
3409
3409
3410
3410
3411
3411
3412
3412

*/

*/

*/
INS
INS
INS
INS
INS
INS
ALA
ALA
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS

ABB Oy Distribution Automation

Event List for RET 545

Default ma
/* BIO1 / Rev C BIO1

January 20 2005

*/
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11
E12
E13
E14
E15
E16
E17
E18
E19
E20
E21
E22
E23
E24
E25
E26
E27
E28
E29
E30
E31

15
15
15
15
15
15
15
15
15
15
15

E32
E33
E34
E35
E36
E37
E38
E39
E40
E41
E42

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT

1
2
4
8
16
32
64
128
256
512
1024
2048
4096
8192
16384
32768
65536
131072
262144
524288
1048576
2097152
4194304
8388608
16777216
33554432
67108864
134217728
268435456
536870912
1073741824
2147483648
0
1
2
4
8
16
32
64
128
256
512
1024

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16

1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0

F015I001
F015I001
F015I002
F015I002
F015I003
F015I003
F015I004
F015I004
F015I005
F015I005
F015I006
F015I006
F015I007
F015I007
F015I008
F015I008
F015I009
F015I009
F015I010
F015I010
F015I011
F015I011
F015I012
F015I012
F015O001
F015O001
F015O002
F015O002
F015O003
F015O003
F015O004
F015O004

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated

Binary input 1
Binary input 1
Binary input 2
Binary input 2
Binary input 3
Binary input 3
Binary input 4
Binary input 4
Binary input 5
Binary input 5
Binary input 6
Binary input 6
Binary input 7
Binary input 7
Binary input 8
Binary input 8
Binary input 9
Binary input 9
Binary input 10
Binary input 10
Binary input 11
Binary input 11
Binary input 12
Binary input 12
Binary output 1
Binary output 1
Binary output 2
Binary output 2
Binary output 3
Binary output 3
Binary output 4
Binary output 4

INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS

3501
3501
3502
3502
3503
3503
3504
3504
3505
3505
3506
3506
3507
3507
3508
3508
3509
3509
3510
3510
3511
3511
3512
3512
3513
3513
3514
3514
3515
3515
3516
3516

0
0
0
0
0
0
0
0
0
0
0

17
17
18
18
19
19
20
20
21
21
22

1
0
1
0
1
0
1
0
1
0
1

F015O005
F015O005
F015O006
F015O006
F015I021
F015I021
F015I022
F015I022
F015I023
F015I023
F015I024

Reset
Activated
Reset
Activated
Stop
Start
Stop
Start
Stop
Start
Stop

Binary output 5 INS


Binary output 5 INS
Binary output 6 INS
Binary output 6 INS
Binary input 1 osINS
Binary input 1 osINS
Binary input 2 osINS
Binary input 2 osINS
Binary input 3 osINS
Binary input 3 osINS
Binary input 4 osINS

3517
3517
3518
3518
3519
3519
3520
3520
3521
3521
3522

ABB Oy Distribution Automation

/* BIO1 / Rev C BIO1

Event List for RET 545

January 20 2005

15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15

E43
E44
E45
E46
E47
E48
E49
E50
E51
E52
E53
E54
E55
E56
E57
E58
E59
E60
E61
E62
E63

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_COUN
EV_COUN
EV_COUN
EV_COUN
Default ma

2048
4096
8192
16384
32768
65536
131072
262144
524288
1048576
2097152
4194304
8388608
16777216
33554432
67108864
134217728
268435456
536870912
1073741824
2147483648
0

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

22
23
23
24
24
25
25
26
26
27
27
28
28
29
29
30
30
31
32
33
34

0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
1
1
1

F015I024
F015I025
F015I025
F015I026
F015I026
F015I027
F015I027
F015I028
F015I028
F015I029
F015I029
F015I030
F015I030
F015I031
F015I031
F015I032
F015I032
F015I041
F015I042
F015I043
F015I044

Start
Stop
Start
Stop
Start
Stop
Start
Stop
Start
Stop
Start
Stop
Start
Stop
Start
Stop
Start
Updated
Updated
Updated
Updated

Binary input 4 osINS


Binary input 5 osINS
Binary input 5 osINS
Binary input 6 osINS
Binary input 6 osINS
Binary input 7 osINS
Binary input 7 osINS
Binary input 8 osINS
Binary input 8 osINS
Binary input 9 o INS
Binary input 9 o INS
Binary input 10 oINS
Binary input 10 oINS
Binary input 11 oINS
Binary input 11 oINS
Binary input 12 oINS
Binary input 12 oINS
Counter 1
INS
Counter 2
INS
Counter 3
INS
Counter 4
INS

3522
3523
3523
3524
3524
3525
3525
3526
3526
3527
3527
3528
3528
3529
3529
3530
3530
3531
3532
3533
3534

16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11
E12
E13
E14
E15
E16
E17
E18
E19
E20
E21
E22

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT

1
2
4
8
16
32
64
128
256
512
1024
2048
4096
8192
16384
32768
65536
131072
262144
524288
1048576
2097152
4194304

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12

1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1

F016I001
F016I001
F016I002
F016I002
F016I003
F016I003
F016I004
F016I004
F016I005
F016I005
F016I006
F016I006
F016I007
F016I007
F016I008
F016I008
F016I009
F016I009
F016I010
F016I010
F016I011
F016I011
F016I012

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset

Binary input 1
Binary input 1
Binary input 2
Binary input 2
Binary input 3
Binary input 3
Binary input 4
Binary input 4
Binary input 5
Binary input 5
Binary input 6
Binary input 6
Binary input 7
Binary input 7
Binary input 8
Binary input 8
Binary input 9
Binary input 9
Binary input 10
Binary input 10
Binary input 11
Binary input 11
Binary input 12

3601
3601
3602
3602
3603
3603
3604
3604
3605
3605
3606
3606
3607
3607
3608
3608
3609
3609
3610
3610
3611
3611
3612

*/
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS

ABB Oy Distribution Automation

/* BIO2 / Rev C BIO2

Event List for RET 545

16
16
16
16
16
16
16
16
16

E23
E24
E25
E26
E27
E28
E29
E30
E31

16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

E32
E33
E34
E35
E36
E37
E38
E39
E40
E41
E42
E43
E44
E45
E46
E47
E48
E49
E50
E51
E52
E53
E54
E55
E56
E57
E58
E59
E60
E61
E62
E63

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_COUN
EV_COUN
EV_COUN
EV_COUN
Default ma

8388608
16777216
33554432
67108864
134217728
268435456
536870912
1073741824
2147483648
0
1
2
4
8
16
32
64
128
256
512
1024
2048
4096
8192
16384
32768
65536
131072
262144
524288
1048576
2097152
4194304
8388608
16777216
33554432
67108864
134217728
268435456
536870912
1073741824
2147483648
0

EV_NODAT
EV_NODAT

1
2

January 20 2005

0
0
0
0
0
0
0
0
0

12
13
13
14
14
15
15
16
16

0
1
0
1
0
1
0
1
0

F016I012
F016O001
F016O001
F016O002
F016O002
F016O003
F016O003
F016O004
F016O004

Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated

Binary input 12
Binary output 1
Binary output 1
Binary output 2
Binary output 2
Binary output 3
Binary output 3
Binary output 4
Binary output 4

INS
INS
INS
INS
INS
INS
INS
INS
INS

3612
3613
3613
3614
3614
3615
3615
3616
3616

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

17
17
18
18
19
19
20
20
21
21
22
22
23
23
24
24
25
25
26
26
27
27
28
28
29
29
30
30
31
32
33
34

1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
1
1
1

F016O005
F016O005
F016O006
F016O006
F016I021
F016I021
F016I022
F016I022
F016I023
F016I023
F016I024
F016I024
F016I025
F016I025
F016I026
F016I026
F016I027
F016I027
F016I028
F016I028
F016I029
F016I029
F016I030
F016I030
F016I031
F016I031
F016I032
F016I032
F016I041
F016I042
F016I043
F016I044

Reset
Activated
Reset
Activated
Stop
Start
Stop
Start
Stop
Start
Stop
Start
Stop
Start
Stop
Start
Stop
Start
Stop
Start
Stop
Start
Stop
Start
Stop
Start
Stop
Start
Updated
Updated
Updated
Updated

Binary output 5 INS


Binary output 5 INS
Binary output 6 INS
Binary output 6 INS
Binary input 1 osINS
Binary input 1 osINS
Binary input 2 osINS
Binary input 2 osINS
Binary input 3 osINS
Binary input 3 osINS
Binary input 4 osINS
Binary input 4 osINS
Binary input 5 osINS
Binary input 5 osINS
Binary input 6 osINS
Binary input 6 osINS
Binary input 7 osINS
Binary input 7 osINS
Binary input 8 osINS
Binary input 8 osINS
Binary input 9 o INS
Binary input 9 o INS
Binary input 10 oINS
Binary input 10 oINS
Binary input 11 oINS
Binary input 11 oINS
Binary input 12 oINS
Binary input 12 oINS
Counter 1
INS
Counter 2
INS
Counter 3
INS
Counter 4
INS

3617
3617
3618
3618
3619
3619
3620
3620
3621
3621
3622
3622
3623
3623
3624
3624
3625
3625
3626
3626
3627
3627
3628
3628
3629
3629
3630
3630
3631
3632
3633
3634

0
0

1
1

Binary input 1
Binary input 1

3701
3701

*/
17 E0
17 E1

1 F017I001 Reset
0 F017I001 Activated

INS
INS

ABB Oy Distribution Automation

Event List for RET 545

17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17

E2
E3
E4
E5
E6
E7
E8
E9
E10
E11
E12
E13
E14
E15
E16
E17
E18
E19
E20
E21
E22
E23
E24
E25
E26
E27
E28
E29
E30
E31

17
17
17
17
17
17
17
17
17
17
17
17
17
17
17

E32
E33
E34
E35
E36
E37
E38
E39
E40
E41
E42
E43
E44
E45
E46

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT

4
8
16
32
64
128
256
512
1024
2048
4096
8192
16384
32768
65536
131072
262144
524288
1048576
2097152
4194304
8388608
16777216
33554432
67108864
134217728
268435456
536870912
1073741824
2147483648
0
1
2
4
8
16
32
64
128
256
512
1024
2048
4096
8192
16384

January 20 2005

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16

1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0

F017I002
F017I002
F017I003
F017I003
F017I004
F017I004
F017I005
F017I005
F017I006
F017I006
F017I007
F017I007
F017I008
F017I008
F017I009
F017I009
F017I010
F017I010
F017O001
F017O001
F017O002
F017O002
F017O003
F017O003
F017O004
F017O004
F017O005
F017O005
F017O006
F017O006

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated

Binary input 2
Binary input 2
Binary input 3
Binary input 3
Binary input 4
Binary input 4
Binary input 5
Binary input 5
Binary input 6
Binary input 6
Binary input 7
Binary input 7
Binary input 8
Binary input 8
Binary input 9
Binary input 9
Binary input 10
Binary input 10
Binary output 1
Binary output 1
Binary output 2
Binary output 2
Binary output 3
Binary output 3
Binary output 4
Binary output 4
Binary output 5
Binary output 5
Binary output 6
Binary output 6

INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS

3702
3702
3703
3703
3704
3704
3705
3705
3706
3706
3707
3707
3708
3708
3709
3709
3710
3710
3711
3711
3712
3712
3713
3713
3714
3714
3715
3715
3716
3716

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

17
17
18
18
19
19
20
20
21
21
22
22
23
23
24

1
0
1
0
1
0
1
0
1
0
1
0
1
0
1

F017I021
F017I021
F017I022
F017I022
F017I023
F017I023
F017I024
F017I024
F017I025
F017I025
F017I026
F017I026
F017I027
F017I027
F017I028

Stop
Start
Stop
Start
Stop
Start
Stop
Start
Stop
Start
Stop
Start
Stop
Start
Stop

Binary input 1 osINS


Binary input 1 osINS
Binary input 2 osINS
Binary input 2 osINS
Binary input 3 osINS
Binary input 3 osINS
Binary input 4 osINS
Binary input 4 osINS
Binary input 5 osINS
Binary input 5 osINS
Binary input 6 osINS
Binary input 6 osINS
Binary input 7 osINS
Binary input 7 osINS
Binary input 8 osINS

3717
3717
3718
3718
3719
3719
3720
3720
3721
3721
3722
3722
3723
3723
3724

ABB Oy Distribution Automation

Event List for RET 545

/* LocalMMI027 / Rev D LocalMMI

/* 100028 / Rev A MMIWAKE

/* 100029 / Rev A INDRESET

/* 100031 / Rev D NOC3Low

/* 100032 / Rev C NOC3High

January 20 2005

17
17
17
17
17
17
17

E47
E48
E49
E50
E51
E52
E53

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_COUN
EV_COUN
Default ma

32768
65536
131072
262144
524288
1048576
2097152
0

0
0
0
0
0
0
0

24
25
25
26
26
27
28

0
1
0
1
0
1
1

F017I028
F017I029
F017I029
F017I030
F017I030
F017I041
F017I042

Start
Stop
Start
Stop
Start
Updated
Updated

Binary input 8 osINS


Binary input 9 osINS
Binary input 9 osINS
Binary input 10 oINS
Binary input 10 oINS
Counter 1
INS
Counter 2
INS

3724
3725
3725
3726
3726
3727
3728

27
27
27
27
27
27
27

E0
E1
E2
E3
E4
E5
E6

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
16
32
64
0

0
0
0
0
0
0
0

0
0
1
2
3
3
5

0
0
0
0
0
0
0

OFF
Backlight
INS
ON
Backlight
INS
Password changINS
Setting done
INS
Operator leveMoving to
INS
Technical lev Moving to
INS
Language changINS

4700
4700
4701
4702
4703
4703
4705

28 E0
28 E1

EV_NODAT
EV_NODAT
Default ma

1
2
0

0
0

99
0

00-

Activated

MMI backligth

INS

4899
4800

29 E1
29 E3
29 E5

EV_NODAT
EV_NODAT
EV_NODAT
Default ma

2
8
32
42

1
1
1

0
1
2

000-

Reset
Reset
Reset

Indications
INS
Indications, latchINS
Indicat., latched, INS

4900
4901
4902

31
31
31
31
31
31
31
31
31
31
31
31

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11

EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
16
32
64
128
256
512
1024
2048
63

1
1
1
1
1
1
0
0
0
0
0
0

0
0
1
1
2
2
3
3
4
4
5
5

0
0
0
0
0
0
0
0
0
0
0
0

F031O001
F031O001
F031O002
F031O002
F031O003
F031O003
F031I004
F031I004
F031I005
F031I005
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On

START signal froSTR


START signal froSTR
TRIP signal fromTRP
TRIP signal fromTRP
CBFP signal fromALA
CBFP signal fromALA
BS1 signal of 3I>BLK
BS1 signal of 3I>BLK
BS2 signal of 3I>BLK
BS2 signal of 3I>BLK
Test mode of 3I>INS
Test mode of 3I>INS

5100
5100
5101
5101
5102
5102
5103
5103
5104
5104
5105
5105

32
32
32
32
32

E0
E1
E2
E3
E4

EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1

1
2
4
8
16

1
1
1
1
1

0
0
1
1
2

0
0
0
0
0

F032O002
F032O002
F032O003
F032O003
F032O004

Reset
Activated
Reset
Activated
Reset

START signal froSTR


START signal froSTR
TRIP signal fromTRP
TRIP signal fromTRP
CBFP signal fromALA

5200
5200
5201
5201
5202

*/

*/

*/

*/

*/

ABB Oy Distribution Automation

Event List for RET 545

/* 100033 / Rev C NOC3Inst

/* 100034 / Rev D Inrush3

January 20 2005

32
32
32
32
32
32
32
32
32

E5
E6
E7
E8
E9
E10
E11
E12
E13

EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

32
64
128
256
512
1024
2048
4096
8192
63

1
0
0
0
0
0
0
0
0

2
3
3
4
4
5
5
6
6

0
0
0
0
0
0
0
0
0

F032O004
F032O001
F032O001
F032I004
F032I004
F032I005
F032I005
-

Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On

CBFP signal fromALA


BSOUT signal fr BLK
BSOUT signal fr BLK
BS1 signal of 3I>BLK
BS1 signal of 3I>BLK
BS2 signal of 3I>BLK
BS2 signal of 3I>BLK
Test mode of 3I>INS
Test mode of 3I>INS

5202
5203
5203
5204
5204
5205
5205
5206
5206

33
33
33
33
33
33
33
33
33
33
33
33
33
33

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11
E12
E13

EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
16
32
64
128
256
512
1024
2048
4096
8192
63

1
1
1
1
1
1
0
0
0
0
0
0
0
0

0
0
1
1
2
2
3
3
4
4
5
5
6
6

0
0
0
0
0
0
0
0
0
0
0
0
0
0

F033O002
F033O002
F033O003
F033O003
F033O004
F033O004
F033O001
F033O001
F033I004
F033I004
F033I005
F033I005
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On

START signal froSTR


START signal froSTR
TRIP signal fromTRP
TRIP signal fromTRP
CBFP signal fromALA
CBFP signal fromALA
BSOUT signal fr BLK
BSOUT signal fr BLK
BS1 signal of 3I>BLK
BS1 signal of 3I>BLK
BS2 signal of 3I>BLK
BS2 signal of 3I>BLK
Test mode of 3I>INS
Test mode of 3I>INS

5300
5300
5301
5301
5302
5302
5303
5303
5304
5304
5305
5305
5306
5306

34
34
34
34

E0
E1
E2
E3

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
3

1
1
0
0

0
0
1
1

0
0
0
0

F034O001
F034O001
-

Reset
Activated
Off
On

START signal froSTR


START signal froSTR
Test mode of Inr INS
Test mode of Inr INS

5400
5400
5401
5401

35
35
35
35
35
35
35
35
35
35
35
35
35

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11
E12

EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT

1
2
4
8
16
32
64
128
256
512
1024
2048
4096

1
1
1
1
1
1
0
0
0
0
0
0
0

0
0
1
1
2
2
3
3
4
4
5
5
6

0
0
0
0
0
0
0
0
0
0
0
0
0

F035O002
F035O002
F035O003
F035O003
F035O004
F035O004
F035O001
F035O001
F035I016
F035I016
F035I017
F035I017
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off

START signal froSTR


START signal froSTR
TRIP signal fromTRP
TRIP signal fromTRP
CBFP signal fromALA
CBFP signal fromALA
DIRECTION signALA
DIRECTION signALA
BS1 signal of 3I>BLK
BS1 signal of 3I>BLK
BS2 signal of 3I>BLK
BS2 signal of 3I>BLK
Test mode of 3I>INS

5500
5500
5501
5501
5502
5502
5503
5503
5504
5504
5505
5505
5506

*/

*/

/* 100035 / Rev F DOC6Low

*/

ABB Oy Distribution Automation

/* 100036 / Rev F DOC6High

/* 100037 / Rev F DOC6Inst

/* 100038 / Rev E NEF1Low

Event List for RET 545

January 20 2005

35 E13

EV_NODAT
Default ma

8192
63

0-

On

Test mode of 3I>INS

5506

36
36
36
36
36
36
36
36
36
36
36
36
36
36
36
36

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11
E12
E13
E14
E15

EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
16
32
64
128
256
512
1024
2048
4096
8192
16384
32768
63

1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0

0
0
1
1
2
2
3
3
4
4
5
5
6
6
7
7

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

F036O003
F036O003
F036O004
F036O004
F036O005
F036O005
F036O002
F036O002
F036O001
F036O001
F036I016
F036I016
F036I017
F036I017
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On

START signal froSTR


START signal froSTR
TRIP signal fromTRP
TRIP signal fromTRP
CBFP signal fromALA
CBFP signal fromALA
BSOUT signal fr BLK
BSOUT signal fr BLK
DIRECTION signALA
DIRECTION signALA
BS1 signal of 3I>BLK
BS1 signal of 3I>BLK
BS2 signal of 3I>BLK
BS2 signal of 3I>BLK
Test mode of 3I>INS
Test mode of 3I>INS

5600
5600
5601
5601
5602
5602
5603
5603
5604
5604
5605
5605
5606
5606
5607
5607

37
37
37
37
37
37
37
37
37
37
37
37
37
37
37
37

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11
E12
E13
E14
E15

EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
16
32
64
128
256
512
1024
2048
4096
8192
16384
32768
63

1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0

0
0
1
1
2
2
3
3
4
4
5
5
6
6
7
7

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

F037O003
F037O003
F037O004
F037O004
F037O005
F037O005
F037O002
F037O002
F037O001
F037O001
F037I016
F037I016
F037I017
F037I017
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On

START signal froSTR


START signal froSTR
TRIP signal fromTRP
TRIP signal fromTRP
CBFP signal fromALA
CBFP signal fromALA
BSOUT signal fr BLK
BSOUT signal fr BLK
DIRECTION signALA
DIRECTION signALA
BS1 signal of 3I>BLK
BS1 signal of 3I>BLK
BS2 signal of 3I>BLK
BS2 signal of 3I>BLK
Test mode of 3I>INS
Test mode of 3I>INS

5700
5700
5701
5701
5702
5702
5703
5703
5704
5704
5705
5705
5706
5706
5707
5707

38
38
38
38
38
38
38

E0
E1
E2
E3
E4
E5
E6

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT

1
2
4
8
16
32
64

1
1
1
1
1
1
0

0
0
1
1
2
2
3

0
0
0
0
0
0
0

F038O001
F038O001
F038O002
F038O002
F038O003
F038O003
F038I002

Reset
Activated
Reset
Activated
Reset
Activated
Reset

START signal froSTR


START signal froSTR
TRIP signal fromTRP
TRIP signal fromTRP
CBFP signal fromALA
CBFP signal fromALA
BS1 signal of Io>BLK

5800
5800
5801
5801
5802
5802
5803

*/

*/

*/

ABB Oy Distribution Automation

/* 100039 / Rev C NEF1High

/* 100040 / Rev D DEF2Low

/* 100041 / Rev D DEF2High

Event List for RET 545

January 20 2005

38
38
38
38
38

E7
E8
E9
E10
E11

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

128
256
512
1024
2048
63

0
0
0
0
0

3
4
4
5
5

0
0
0
0
0

F038I002
F038I003
F038I003
-

Activated
Reset
Activated
Off
On

BS1 signal of Io>BLK


BS2 signal of Io>BLK
BS2 signal of Io>BLK
Test mode of Io>INS
Test mode of Io>INS

5803
5804
5804
5805
5805

39
39
39
39
39
39
39
39
39
39
39
39

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
16
32
64
128
256
512
1024
2048
63

1
1
1
1
1
1
0
0
0
0
0
0

0
0
1
1
2
2
3
3
4
4
7
7

0
0
0
0
0
0
0
0
0
0
0
0

F039O001
F039O001
F039O002
F039O002
F039O003
F039O003
F039I002
F039I002
F039I003
F039I003
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On

START signal froSTR


START signal froSTR
TRIP signal fromTRP
TRIP signal fromTRP
CBFP signal fromALA
CBFP signal fromALA
BS1 signal of Io>BLK
BS1 signal of Io>BLK
BS2 signal of Io>BLK
BS2 signal of Io>BLK
Test mode of Io>INS
Test mode of Io>INS

5900
5900
5901
5901
5902
5902
5903
5903
5904
5904
5907
5907

40
40
40
40
40
40
40
40
40
40
40
40

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
16
32
64
128
256
512
1024
2048
63

1
1
1
1
1
1
0
0
0
0
0
0

0
0
1
1
2
2
3
3
4
4
5
5

0
0
0
0
0
0
0
0
0
0
0
0

F040O001
F040O001
F040O002
F040O002
F040O003
F040O003
F040I005
F040I005
F040I006
F040I006
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On

START signal froSTR


START signal froSTR
TRIP signal fromTRP
TRIP signal fromTRP
CBFP signal fromALA
CBFP signal fromALA
BS1 signal of Io>BLK
BS1 signal of Io>BLK
BS2 signal of Io>BLK
BS2 signal of Io>BLK
Test mode of Io>INS
Test mode of Io>INS

6000
6000
6001
6001
6002
6002
6003
6003
6004
6004
6005
6005

41
41
41
41
41
41
41
41
41
41
41

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT

1
2
4
8
16
32
64
128
256
512
1024

1
1
1
1
1
1
0
0
0
0
0

0
0
1
1
2
2
3
3
4
4
5

0
0
0
0
0
0
0
0
0
0
0

F041O001
F041O001
F041O002
F041O002
F041O003
F041O003
F041I005
F041I005
F041I006
F041I006
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off

START signal froSTR


START signal froSTR
TRIP signal fromTRP
TRIP signal fromTRP
CBFP signal fromALA
CBFP signal fromALA
BS1 signal of Io>BLK
BS1 signal of Io>BLK
BS2 signal of Io>BLK
BS2 signal of Io>BLK
Test mode of Io>INS

6100
6100
6101
6101
6102
6102
6103
6103
6104
6104
6105

*/

*/

*/

ABB Oy Distribution Automation

/* 100042 / Rev D DEF2Inst

/* 100044 / Rev D ROV1Low

/* 100045 / Rev D ROV1High

/* 100046 / Rev D ROV1Inst

Event List for RET 545

January 20 2005

41 E11

EV_NODAT
Default ma

2048
63

0-

On

Test mode of Io>INS

6105

42
42
42
42
42
42
42
42
42
42
42
42

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
16
32
64
128
256
512
1024
2048
63

1
1
1
1
1
1
0
0
0
0
0
0

0
0
1
1
2
2
3
3
4
4
5
5

0
0
0
0
0
0
0
0
0
0
0
0

F042O001
F042O001
F042O002
F042O002
F042O003
F042O003
F042I005
F042I005
F042I006
F042I006
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On

START signal froSTR


START signal froSTR
TRIP signal fromTRP
TRIP signal fromTRP
CBFP signal fromALA
CBFP signal fromALA
BS1 signal of Io>BLK
BS1 signal of Io>BLK
BS2 signal of Io>BLK
BS2 signal of Io>BLK
Test mode of Io>INS
Test mode of Io>INS

6200
6200
6201
6201
6202
6202
6203
6203
6204
6204
6205
6205

44
44
44
44
44
44
44
44
44
44

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
16
32
64
128
256
512
15

1
1
1
1
0
0
0
0
0
0

0
0
1
1
2
2
3
3
4
4

0
0
0
0
0
0
0
0
0
0

F044O001
F044O001
F044O002
F044O002
F044I002
F044I002
F044I003
F044I003
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On

START signal froSTR


START signal froSTR
TRIP signal fromTRP
TRIP signal fromTRP
BS1 signal of UoBLK
BS1 signal of UoBLK
BS2 signal of UoBLK
BS2 signal of UoBLK
Test mode of UoINS
Test mode of UoINS

6400
6400
6401
6401
6402
6402
6403
6403
6404
6404

45
45
45
45
45
45
45
45
45
45

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
16
32
64
128
256
512
15

1
1
1
1
0
0
0
0
0
0

0
0
1
1
2
2
3
3
4
4

0
0
0
0
0
0
0
0
0
0

F045O001
F045O001
F045O002
F045O002
F045I002
F045I002
F045I003
F045I003
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On

START signal froSTR


START signal froSTR
TRIP signal fromTRP
TRIP signal fromTRP
BS1 signal of UoBLK
BS1 signal of UoBLK
BS2 signal of UoBLK
BS2 signal of UoBLK
Test mode of UoINS
Test mode of UoINS

6500
6500
6501
6501
6502
6502
6503
6503
6504
6504

46
46
46
46
46

E0
E1
E2
E3
E4

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT

1
2
4
8
16

1
1
1
1
0

0
0
1
1
2

0
0
0
0
0

F046O001
F046O001
F046O002
F046O002
F046I002

Reset
Activated
Reset
Activated
Reset

START signal froSTR


START signal froSTR
TRIP signal fromTRP
TRIP signal fromTRP
BS1 signal of UoBLK

6600
6600
6601
6601
6602

*/

*/

*/

*/

ABB Oy Distribution Automation

Event List for RET 545

/* 100048 / Rev E TOL3Dev

46
46
46
46
46

E5
E6
E7
E8
E9

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

32
64
128
256
512
15

0
0
0
0
0

2
3
3
4
4

0
0
0
0
0

F046I002
F046I003
F046I003
-

Activated
Reset
Activated
Off
On

BS1 signal of UoBLK


BS2 signal of UoBLK
BS2 signal of UoBLK
Test mode of UoINS
Test mode of UoINS

6602
6603
6603
6604
6604

48
48
48
48
48
48
48
48
48
48
48
48
48
48
48
48
48
48
48
48
48
48
48

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11
E12
E13
E14
E15
E16
E17
E18
E19
E20
E21
E22

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_FLOAT
EV_INT32
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_INT32
Default ma

1
2
4
8
16
32
64
128
256
512
1024
2048
4096
8192
16384
32768
65536
131072
262144
524288
1048576
2097152
4194304
4177983

1
1
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0

0
0
1
1
2
2
3
3
4
5
6
6
7
7
8
8
9
9
10
10
11
11
12

0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0

F048O001
F048O001
F048O002
F048O002
F048I010
F048I010
F048O003
F048O006
F048O009
F048O009
F048O007

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
-

START signal froSTR


START signal froSTR
TRIP signal fromTRP
TRIP signal fromTRP
CBFP signal fromALA
CBFP signal fromALA
BLOCK signal ofBLK
BLOCK signal ofBLK
Calculated temp TMP
Cooling time for TIM
Test mode of TOINS
Test mode of TOINS
Sensor error signALA
Sensor error signALA
START from TO STR
START from TO STR
TRIP from TOL3 TRP
TRIP from TOL3 TRP
START from TO STR
START from TO STR
TRIP from TOL3 TRP
TRIP from TOL3 TRP
Predicted trip timTIM

6800
6800
6801
6801
6802
6802
6803
6803
6804
6805
6806
6806
6807
6807
6808
6808
6809
6809
6810
6810
6811
6811
6812

53
53
53
53
53
53
53
53
53
53
53
53

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11

EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
16
32
64
128
256
512
1024
2048
63

1
1
1
1
1
1
0
0
0
0
0
0

0
0
1
1
2
2
3
3
4
4
5
5

0
0
0
0
0
0
0
0
0
0
0
0

F053O001
F053O001
F053O002
F053O002
F053O003
F053O003
F053I004
F053I004
F053I005
F053I005
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On

START signal froSTR


START signal froSTR
TRIP signal fromTRP
TRIP signal fromTRP
CBFP signal fromALA
CBFP signal fromALA
BS1 signal of 3I>BLK
BS1 signal of 3I>BLK
BS2 signal of 3I>BLK
BS2 signal of 3I>BLK
Test mode of 3I>INS
Test mode of 3I>INS

7300
7300
7301
7301
7302
7302
7303
7303
7304
7304
7305
7305

*/

/* 100053 / Rev A NOC3LowB

/* 100062 / Rev E OV3Low

January 20 2005

*/

*/

ABB Oy Distribution Automation

/* 100063 / Rev D OV3High

/* 100064 / Rev D UV3Low

/* 100065 / Rev D UV3High

Event List for RET 545

January 20 2005

62
62
62
62
62
62
62
62
62
62

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9

EV_3BIT_2
EV_3BIT_2
EV_3BIT_2
EV_3BIT_2
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
16
32
64
128
256
512
15

1
1
1
1
0
0
0
0
0
0

0
0
1
1
2
2
3
3
4
4

0
0
0
0
0
0
0
0
0
0

F062O001
F062O001
F062O002
F062O002
F062I004
F062I004
F062I005
F062I005
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On

START signal froSTR


START signal froSTR
TRIP signal fromTRP
TRIP signal fromTRP
BS1 signal of 3UBLK
BS1 signal of 3UBLK
BS2 signal of 3UBLK
BS2 signal of 3UBLK
Test mode of 3UINS
Test mode of 3UINS

8200
8200
8201
8201
8202
8202
8203
8203
8204
8204

63
63
63
63
63
63
63
63
63
63

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9

EV_3BIT_2
EV_3BIT_2
EV_3BIT_2
EV_3BIT_2
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
16
32
64
128
256
512
15

1
1
1
1
0
0
0
0
0
0

0
0
1
1
2
2
3
3
4
4

0
0
0
0
0
0
0
0
0
0

F063O001
F063O001
F063O002
F063O002
F063I004
F063I004
F063I005
F063I005
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On

START signal froSTR


START signal froSTR
TRIP signal fromTRP
TRIP signal fromTRP
BS1 signal of 3UBLK
BS1 signal of 3UBLK
BS2 signal of 3UBLK
BS2 signal of 3UBLK
Test mode of 3UINS
Test mode of 3UINS

8300
8300
8301
8301
8302
8302
8303
8303
8304
8304

64
64
64
64
64
64
64
64
64
64

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9

EV_3BIT_2
EV_3BIT_2
EV_3BIT_2
EV_3BIT_2
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
16
32
64
128
256
512
15

1
1
1
1
0
0
0
0
0
0

0
0
1
1
2
2
3
3
4
4

0
0
0
0
0
0
0
0
0
0

F064O001
F064O001
F064O002
F064O002
F064I004
F064I004
F064I005
F064I005
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On

START signal froSTR


START signal froSTR
TRIP signal fromTRP
TRIP signal fromTRP
BS1 signal of 3UBLK
BS1 signal of 3UBLK
BS2 signal of 3UBLK
BS2 signal of 3UBLK
Test mode of 3UINS
Test mode of 3UINS

8400
8400
8401
8401
8402
8402
8403
8403
8404
8404

65
65
65
65
65
65
65
65
65
65

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9

EV_3BIT_2
EV_3BIT_2
EV_3BIT_2
EV_3BIT_2
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT

1
2
4
8
16
32
64
128
256
512

1
1
1
1
0
0
0
0
0
0

0
0
1
1
2
2
3
3
4
4

0
0
0
0
0
0
0
0
0
0

F065O001
F065O001
F065O002
F065O002
F065I004
F065I004
F065I005
F065I005
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On

START signal froSTR


START signal froSTR
TRIP signal fromTRP
TRIP signal fromTRP
BS1 signal of 3UBLK
BS1 signal of 3UBLK
BS2 signal of 3UBLK
BS2 signal of 3UBLK
Test mode of 3UINS
Test mode of 3UINS

8500
8500
8501
8501
8502
8502
8503
8503
8504
8504

*/

*/

*/

ABB Oy Distribution Automation

/* 100068 / Rev F OE1Low

/* 100069 / Rev F OE1High

/* 100072 / Rev F Freq1St1

/* 100073 / Rev F Freq1St2

Event List for RET 545

Default ma

15

January 20 2005

*/
68
68
68
68
68
68
68
68
68
68

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
16
32
64
128
256
512
63

1
1
1
1
1
1
0
0
0
0

0
0
1
1
2
2
3
3
4
4

0
0
0
0
0
0
0
0
0
0

F068O001
F068O001
F068O002
F068O002
F068O003
F068O003
F068I002
F068I002
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On

START signal froSTR


START signal froSTR
TRIP signal fromTRP
TRIP signal fromTRP
CBFP signal fromALA
CBFP signal fromALA
BLOCK signal ofBLK
BLOCK signal ofBLK
Test mode of OEINS
Test mode of OEINS

8800
8800
8801
8801
8802
8802
8803
8803
8804
8804

69
69
69
69
69
69
69
69
69
69

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
16
32
64
128
256
512
63

1
1
1
1
1
1
0
0
0
0

0
0
1
1
2
2
3
3
4
4

0
0
0
0
0
0
0
0
0
0

F069O001
F069O001
F069O002
F069O002
F069I002
F069I002
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On

START signal froSTR


START signal froSTR
TRIP signal fromTRP
TRIP signal fromTRP
CBFP signal fromALA
CBFP signal fromALA
BLOCK signal ofBLK
BLOCK signal ofBLK
Test mode of OEINS
Test mode of OEINS

8900
8900
8901
8901
8902
8902
8903
8903
8904
8904

72
72
72
72
72
72
72
72
72
72
72
72
72
72

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11
E12
E13

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
16
32
64
128
256
512
1024
2048
4096
8192
255

1
1
1
1
1
1
1
1
0
0
0
0
0
0

0
0
1
1
2
2
3
3
4
4
5
5
6
6

0
0
0
0
0
0
0
0
0
0
0
0
0
0

F072O001
F072O001
F072O002
F072O002
F072O003
F072O003
F072O004
F072O004
F072I004
F072I004
F072I005
F072I005
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On

START1 signal f STR


START1 signal f STR
TRIP1 signal fro TRP
TRIP1 signal fro TRP
START2 signal f STR
START2 signal f STR
TRIP2 signal fro TRP
TRIP2 signal fro TRP
BS1 signal of f>, BLK
BS1 signal of f>, BLK
BS2 signal of f>, BLK
BS2 signal of f>, BLK
Test mode of f>, INS
Test mode of f>, INS

9200
9200
9201
9201
9202
9202
9203
9203
9204
9204
9205
9205
9206
9206

73
73
73
73

E0
E1
E2
E3

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT

1
2
4
8

1
1
1
1

0
0
1
1

0
0
0
0

F073O001
F073O001
F073O002
F073O002

Reset
Activated
Reset
Activated

START1 signal f STR


START1 signal f STR
TRIP1 signal fro TRP
TRIP1 signal fro TRP

9300
9300
9301
9301

*/

*/

*/

ABB Oy Distribution Automation

/* 100074 / Rev F Freq1St3

/* 100075 / Rev F Freq1St4

/* 100076 / Rev F Freq1St5

Event List for RET 545

January 20 2005

73
73
73
73
73
73
73
73
73
73

E4
E5
E6
E7
E8
E9
E10
E11
E12
E13

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

16
32
64
128
256
512
1024
2048
4096
8192
255

1
1
1
1
0
0
0
0
0
0

2
2
3
3
4
4
5
5
6
6

0
0
0
0
0
0
0
0
0
0

F073O003
F073O003
F073O004
F073O004
F073I004
F073I004
F073I005
F073I005
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On

START2 signal f STR


START2 signal f STR
TRIP2 signal fro TRP
TRIP2 signal fro TRP
BS1 signal of f>, BLK
BS1 signal of f>, BLK
BS2 signal of f>, BLK
BS2 signal of f>, BLK
Test mode of f>, INS
Test mode of f>, INS

9302
9302
9303
9303
9304
9304
9305
9305
9306
9306

74
74
74
74
74
74
74
74
74
74
74
74
74
74

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11
E12
E13

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
16
32
64
128
256
512
1024
2048
4096
8192
255

1
1
1
1
1
1
1
1
0
0
0
0
0
0

0
0
1
1
2
2
3
3
4
4
5
5
6
6

0
0
0
0
0
0
0
0
0
0
0
0
0
0

F074O001
F074O001
F074O002
F074O002
F074O003
F074O003
F074O004
F074O004
F074I004
F074I004
F074I005
F074I005
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On

START1 signal f STR


START1 signal f STR
TRIP1 signal fro TRP
TRIP1 signal fro TRP
START2 signal f STR
START2 signal f STR
TRIP2 signal fro TRP
TRIP2 signal fro TRP
BS1 signal of f>, BLK
BS1 signal of f>, BLK
BS2 signal of f>, BLK
BS2 signal of f>, BLK
Test mode of f>, INS
Test mode of f>, INS

9400
9400
9401
9401
9402
9402
9403
9403
9404
9404
9405
9405
9406
9406

75
75
75
75
75
75
75
75
75
75
75
75
75
75

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11
E12
E13

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
16
32
64
128
256
512
1024
2048
4096
8192
255

1
1
1
1
1
1
1
1
0
0
0
0
0
0

0
0
1
1
2
2
3
3
4
4
5
5
6
6

0
0
0
0
0
0
0
0
0
0
0
0
0
0

F075O001
F075O001
F075O002
F075O002
F075O003
F075O003
F075O004
F075O004
F075I004
F075I004
F075I005
F075I005
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On

START1 signal f STR


START1 signal f STR
TRIP1 signal fro TRP
TRIP1 signal fro TRP
START2 signal f STR
START2 signal f STR
TRIP2 signal fro TRP
TRIP2 signal fro TRP
BS1 signal of f>, BLK
BS1 signal of f>, BLK
BS2 signal of f>, BLK
BS2 signal of f>, BLK
Test mode of f>, INS
Test mode of f>, INS

9500
9500
9501
9501
9502
9502
9503
9503
9504
9504
9505
9505
9506
9506

EV_NODAT
EV_NODAT

1
2

1
1

0
0

0 F076O001 Reset
0 F076O001 Activated

START1 signal f STR


START1 signal f STR

9600
9600

*/

*/

*/
76 E0
76 E1

ABB Oy Distribution Automation

/* 100077 / Rev G NPS3Low

/* 100078 / Rev G NPS3High

/* 100090 / Rev D NEF1Inst

Event List for RET 545

January 20 2005

76
76
76
76
76
76
76
76
76
76
76
76

E2
E3
E4
E5
E6
E7
E8
E9
E10
E11
E12
E13

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

4
8
16
32
64
128
256
512
1024
2048
4096
8192
255

1
1
1
1
1
1
0
0
0
0
0
0

1
1
2
2
3
3
4
4
5
5
6
6

0
0
0
0
0
0
0
0
0
0
0
0

F076O002
F076O002
F076O003
F076O003
F076O004
F076O004
F076I004
F076I004
F076I005
F076I005
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On

TRIP1 signal fro TRP


TRIP1 signal fro TRP
START2 signal f STR
START2 signal f STR
TRIP2 signal fro TRP
TRIP2 signal fro TRP
BS1 signal of f>, BLK
BS1 signal of f>, BLK
BS2 signal of f>, BLK
BS2 signal of f>, BLK
Test mode of f>, INS
Test mode of f>, INS

9601
9601
9602
9602
9603
9603
9604
9604
9605
9605
9606
9606

77
77
77
77
77
77
77
77
77
77
77
77

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
16
32
64
128
256
512
1024
2048
63

1
1
1
1
1
1
0
0
0
0
0
0

0
0
1
1
2
2
3
3
4
4
5
5

0
0
0
0
0
0
0
0
0
0
0
0

F077O001
F077O001
F077O002
F077O002
F077O004
F077O004
F077O003
F077O003
F077I006
F077I006
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On

START signal froSTR


START signal froSTR
TRIP signal fromTRP
TRIP signal fromTRP
CBFP signal fromALA
CBFP signal fromALA
BLOCK_OUT sigOUT
BLOCK_OUT sigOUT
BLOCK signal ofBLK
BLOCK signal ofBLK
Test mode of I2>INS
Test mode of I2>INS

9700
9700
9701
9701
9702
9702
9703
9703
9704
9704
9705
9705

78
78
78
78
78
78
78
78
78
78
78
78

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
16
32
64
128
256
512
1024
2048
63

1
1
1
1
1
1
0
0
0
0
0
0

0
0
1
1
2
2
3
3
4
4
5
5

0
0
0
0
0
0
0
0
0
0
0
0

F078O001
F078O001
F078O002
F078O002
F078O004
F078O004
F078O003
F078O003
F078I006
F078I006
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On

START signal froSTR


START signal froSTR
TRIP signal fromTRP
TRIP signal fromTRP
CBFP signal fromALA
CBFP signal fromALA
BLOCK_OUT sigOUT
BLOCK_OUT sigOUT
BLOCK signal ofBLK
BLOCK signal ofBLK
Test mode of I2>INS
Test mode of I2>INS

9800
9800
9801
9801
9802
9802
9803
9803
9804
9804
9805
9805

90
90
90
90

E0
E1
E2
E3

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT

1
2
4
8

1
1
1
1

0
0
1
1

0
0
0
0

F090O001
F090O001
F090O002
F090O002

Reset
Activated
Reset
Activated

START signal froSTR


START signal froSTR
TRIP signal fromTRP
TRIP signal fromTRP

11000
11000
11001
11001

*/

*/

*/

ABB Oy Distribution Automation

/* 100101 / Rev A REF4A

/* 100102 / Rev C REF1A

/* 100106 / Rev A Diff6T

Event List for RET 545

January 20 2005

90
90
90
90
90
90
90
90

E4
E5
E6
E7
E8
E9
E10
E11

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

16
32
64
128
256
512
1024
2048
63

1
1
0
0
0
0
0
0

2
2
3
3
4
4
5
5

0
0
0
0
0
0
0
0

F090O003
F090O003
F090I002
F090I002
F090I003
F090I003
-

Reset
Activated
Reset
Activated
Reset
Activated
Off
On

CBFP signal fromALA


CBFP signal fromALA
BS1 signal of Io>BLK
BS1 signal of Io>BLK
BS2 signal of Io>BLK
BS2 signal of Io>BLK
Test mode of Io>INS
Test mode of Io>INS

11002
11002
11003
11003
11004
11004
11005
11005

101
101
101
101
101
101
101
101
101
101

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_2BIT_1
EV_2BIT_1
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
16
32
64
128
256
512
63

1
1
1
1
1
1
0
0
0
0

0
0
1
1
2
2
3
3
4
4

0
0
0
0
0
0
0
0
0
0

F101O001
F101O001
F101O002
F101O002
F101O003
F101O003
F101I007
F101I007
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On

START signal of STR


START signal of STR
TRIP signal of R TRP
TRIP signal of R TRP
CBFP signal of RALA
CBFP signal of RALA
Blocking of REF4BLK
Blocking of REF4BLK
Test mode of REINS
Test mode of REINS

12100
12100
12101
12101
12102
12102
12103
12103
12104
12104

102
102
102
102
102
102
102
102

E0
E1
E2
E3
E4
E5
E6
E7

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
16
32
64
128
15

1
1
1
1
0
0
0
0

0
0
1
1
2
2
3
3

0
0
0
0
0
0
0
0

F102O001
F102O001
F102O002
F102O002
F102I002
F102I002
-

Reset
Activated
Reset
Activated
Reset
Activated
Off
On

TRIP signal of R TRP


TRIP signal of R TRP
CBFB signal
ALA
CBFB signal
ALA
BLOCK signal ofBLK
BLOCK signal ofBLK
Test mode of REINS
Test mode of REINS

12200
12200
12201
12201
12202
12202
12203
12203

106
106
106
106
106
106
106
106
106
106
106
106
106
106

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11
E12
E13

EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_3BIT_1
EV_NODAT
EV_NODAT

1
2
4
8
16
32
64
128
256
512
1024
2048
4096
8192

1
1
1
1
1
1
0
0
0
0
0
0
0
0

0
0
1
1
2
2
3
3
4
4
5
5
6
6

0
0
0
0
0
0
0
0
0
0
0
0
0
0

F106O002
F106O002
F106O003
F106O003
F106O004
F106O004
F106I025
F106I025

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated

TRIP signal of 3dTRP


TRIP signal of 3dTRP
TRIP signal of 3dTRP
TRIP signal of 3dTRP
CBFP signal 3d ALA
CBFP signal 3d ALA
I2f/I1f> blocking BLK
I2f/I1f> blocking BLK
I5f/I1f> blocking BLK
I5f/I1f> blocking BLK
Waveform block BLK
Waveform block BLK
BS_STAB signa INS
BS_STAB signa INS

12600
12600
12601
12601
12602
12602
12603
12603
12604
12604
12605
12605
12606
12606

*/

*/

*/

ABB Oy Distribution Automation

/* 100110 / Rev E UI6Low

/* 100111 / Rev E UI6High

/* 100112 / Rev D PSV3St1

Event List for RET 545

January 20 2005

106
106
106
106

E14
E15
E16
E17

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

16384
32768
65536
131072
63

0
0
0
0

7
7
8
8

0
0
0
0

F106I026
F106I026
-

Reset
Activated
Off
On

BS_INST signal BLK


BS_INST signal BLK
Test mode of 3d INS
Test mode of 3d INS

12607
12607
12608
12608

110
110
110
110
110
110
110
110
110
110

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
16
32
64
128
256
512
63

1
1
1
1
1
1
0
0
0
0

0
0
1
1
2
2
3
3
4
4

0
0
0
0
0
0
0
0
0
0

F110O001
F110O001
F110O002
F110O002
F110O003
F110O003
F110I004
F110I004
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On

START signal froSTR


START signal froSTR
TRIP signal fromTRP
TRIP signal fromTRP
CBFP signal fromALA
CBFP signal fromALA
BLOCK signal ofBLK
BLOCK signal ofBLK
Test mode of Z< INS
Test mode of Z< INS

13000
13000
13001
13001
13002
13002
13003
13003
13004
13004

111
111
111
111
111
111
111
111
111
111

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
16
32
64
128
256
512
63

1
1
1
1
1
1
0
0
0
0

0
0
1
1
2
2
3
3
4
4

0
0
0
0
0
0
0
0
0
0

F111O001
F111O001
F111O002
F111O002
F111O003
F111O003
F111I004
F111I004
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On

START signal froSTR


START signal froSTR
TRIP signal fromTRP
TRIP signal fromTRP
CBFP signal fromALA
CBFP signal fromALA
BLOCK signal ofBLK
BLOCK signal ofBLK
Test mode of Z< INS
Test mode of Z< INS

13100
13100
13101
13101
13102
13102
13103
13103
13104
13104

112
112
112
112
112
112
112
112
112
112
112
112
112
112
112
112

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11
E12
E13
E14
E15

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT

1
2
4
8
16
32
64
128
256
512
1024
2048
4096
8192
16384
32768

1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0

0
0
1
1
2
2
3
3
4
4
5
5
6
6
7
7

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

F112O001
F112O001
F112O001
F112O001
F112O001
F112O001
F112O002
F112O002
F112O002
F112O002
F112O002
F112O002
F112I004
F112I004
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On

PSV3St1 STARTSTR
PSV3St1 STARTSTR
PSV3St1 STARTSTR
PSV3St1 STARTSTR
PSV3St1 STARTSTR
PSV3St1 STARTSTR
PSV3St1 TRIP UTRP
PSV3St1 TRIP UTRP
PSV3St1 TRIP UTRP
PSV3St1 TRIP UTRP
PSV3St1 TRIP UTRP
PSV3St1 TRIP UTRP
PSV3St1 BLOCKBLK
PSV3St1 BLOCKBLK
Test mode of PSINS
Test mode of PSINS

13200
13200
13201
13201
13202
13202
13203
13203
13204
13204
13205
13205
13206
13206
13207
13207

*/

*/

*/

ABB Oy Distribution Automation

Event List for RET 545

/* 100113 / Rev D PSV3St2

/* 100118 / Rev D FuseFail

/* 100119 / Rev A REF4B

/* 100120 / Rev B COCB1

Default ma

4095

January 20 2005

*/
113
113
113
113
113
113
113
113
113
113
113
113
113
113
113
113

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11
E12
E13
E14
E15

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
16
32
64
128
256
512
1024
2048
4096
8192
16384
32768
4095

1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0

0
0
1
1
2
2
3
3
4
4
5
5
6
6
7
7

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

F113O001
F113O001
F113O001
F113O001
F113O001
F113O001
F113O002
F113O002
F113O002
F113O002
F113O002
F113O002
F113I004
F113I004
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On

PSV3St2 STARTSTR
PSV3St2 STARTSTR
PSV3St2 STARTSTR
PSV3St2 STARTSTR
PSV3St2 STARTSTR
PSV3St2 STARTSTR
PSV3St2 TRIP UTRP
PSV3St2 TRIP UTRP
PSV3St2 TRIP UTRP
PSV3St2 TRIP UTRP
PSV3St2 TRIP UTRP
PSV3St2 TRIP UTRP
PSV3St2 BLOCKBLK
PSV3St2 BLOCKBLK
Test mode of PSINS
Test mode of PSINS

13300
13300
13301
13301
13302
13302
13303
13303
13304
13304
13305
13305
13306
13306
13307
13307

118
118
118
118
118
118
118
118

E0
E1
E2
E3
E4
E5
E6
E7

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
16
32
64
128
15

1
1
1
1
0
0
0
0

0
0
1
1
2
2
3
3

0
0
1
0
0
0
0
0

F118O001
F118O001
F118I002
F118I002
F118I001
F118I001
F118V002
F118V002

Reset
Activated
Open
Closed
Reset
Activated
Off
On

Fuse failure
ALA
Fuse failure
ALA
MCB position POS
MCB position POS
FuseFail blockedBLK
FuseFail blockedBLK
Test mode of Fu INS
Test mode of Fu INS

13800
13800
13801
13801
13802
13802
13803
13803

119
119
119
119
119
119
119
119
119
119

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_2BIT_1
EV_2BIT_1
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
16
32
64
128
256
512
63

1
1
1
1
1
1
0
0
0
0

0
0
1
1
2
2
3
3
4
4

0
0
0
0
0
0
0
0
0
0

F119O001
F119O001
F119O002
F119O002
F119O003
F119O003
F119I007
F119I007
-

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Off
On

START signal of STR


START signal of STR
TRIP signal of R TRP
TRIP signal of R TRP
CBFP signal of RALA
CBFP signal of RALA
Blocking of REF4BLK
Blocking of REF4BLK
Test mode of REINS
Test mode of REINS

13900
13900
13901
13901
13902
13902
13903
13903
13904
13904

120
120
120
120

E0
E1
E2
E3

EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_2BIT_1

1
2
4
8

1
1
1
1

0
0
0
0

1
0
0
0

F120V001
F120V001
F120V001
F120V001

Open (10)
Close (01)
Faulty (11)
Middle (00)

Breaker 1 positioPOS
Breaker 1 positioPOS
Breaker 1 positioPOS
Breaker 1 positioPOS

14000
14000
14000
14000

*/

*/

*/

ABB Oy Distribution Automation

/* 100121 / Rev B COCB2

Event List for RET 545

January 20 2005

120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120

E4
E5
E6
E7
E8
E9
E10
E11
E12
E13
E14
E15
E16
E17
E18
E19
E20
E21
E22
E23
E24
E25
E26
E27
E28

EV_1BIT
EV_1BIT
EV_1BIT
EV_1BIT
EV_1BIT
EV_1BIT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_1BIT
EV_1BIT
EV_NODAT
Default ma

16
32
64
128
256
512
1024
2048
4096
8192
16384
32768
65536
131072
262144
524288
1048576
2097152
4194304
8388608
16777216
33554432
67108864
134217728
268435456
145403647

1
1
1
1
0
1
1
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
0
1
0

1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13

1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0

F120V031
F120V031
F120V030
F120V030
F120V034
F120V034
F120O003
F120O003
F120O004
F120O004
F120O005
F120O005
F120O006
F120O006
F120V035
F120V035
-

Enabled
Breaker 1 open cINS
Disabled
Breaker 1 open cINS
Enabled
Breaker 1 close INS
Disabled
Breaker 1 close INS
Inactive
Breaker 1 invalidINS
Active
Breaker 1 invalidINS
Completed Breaker 1 comm INS
Started
Breaker 1 comm INS
Deactivated Breaker 1 open oINS
Activated
Breaker 1 open oINS
Deactivated Breaker 1 close INS
Activated
Breaker 1 close INS
Normal
Breaker 1 openinINS
Alarm
Breaker 1 openinINS
Normal
Breaker 1 closin INS
Alarm
Breaker 1 closin INS
Normal
Breaker 1 inactivINS
Alarm
Breaker 1 inactivINS
Normal
Breaker 1 cycle INS
Alarm
Breaker 1 cycle INS
Nack
Breaker 1 comm INS
Ack
Breaker 1 comm INS
Inactive
Breaker 1 controINS
Active
Breaker 1 controINS
Unsuccessfu Breaker 1 comm CMS

14001
14001
14002
14002
14003
14003
14004
14004
14005
14005
14006
14006
14007
14007
14008
14008
14009
14009
14010
14010
14011
14011
14012
14012
14013

121
121
121
121
121
121
121
121
121
121
121
121
121
121
121
121
121
121
121

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11
E12
E13
E14
E15
E16
E17
E18

EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_1BIT
EV_1BIT
EV_1BIT
EV_1BIT
EV_1BIT
EV_1BIT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT

1
2
4
8
16
32
64
128
256
512
1024
2048
4096
8192
16384
32768
65536
131072
262144

1
1
1
1
1
1
1
1
0
1
1
1
0
1
0
1
0
1
0

0
0
0
0
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8

1
0
0
0
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0

F121V001
F121V001
F121V001
F121V001
F121V031
F121V031
F121V030
F121V030
F121V034
F121V034
F121O003
F121O003
F121O004

Open (10)
Close (01)
Faulty (11)
Middle (00)
Enabled
Disabled
Enabled
Disabled
Inactive
Active
Completed
Started
Deactivated
Activated
Deactivated
Activated
Normal
Alarm
Normal

14100
14100
14100
14100
14101
14101
14102
14102
14103
14103
14104
14104
14105
14105
14106
14106
14107
14107
14108

*/
Breaker 2 positioPOS
Breaker 2 positioPOS
Breaker 2 positioPOS
Breaker 2 positioPOS
Breaker 2 open cINS
Breaker 2 open cINS
Breaker 2 close INS
Breaker 2 close INS
Breaker 2 invalidINS
Breaker 2 invalidINS
Breaker 2 comm INS
Breaker 2 comm INS
Breaker 2 open oINS
Breaker 2 open oINS
Breaker 2 close INS
Breaker 2 close INS
Breaker 2 openinINS
Breaker 2 openinINS
Breaker 2 closin INS

ABB Oy Distribution Automation

/* 100122 / Rev B CODC1

/* 100123 / Rev B CODC2

Event List for RET 545

January 20 2005

121
121
121
121
121
121
121
121
121
121

E19
E20
E21
E22
E23
E24
E25
E26
E27
E28

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_1BIT
EV_1BIT
EV_NODAT
Default ma

524288
1048576
2097152
4194304
8388608
16777216
33554432
67108864
134217728
268435456
145403647

1
0
1
0
1
0
0
0
1
0

8
9
9
10
10
11
11
12
12
13

0
0
0
0
0
0
0
1
0
0

F121O004
F121O005
F121O005
F121O006
F121O006
F121V035
F121V035
-

Alarm
Breaker 2 closin INS
Normal
Breaker 2 inactivINS
Alarm
Breaker 2 inactivINS
Normal
Breaker 2 cycle INS
Alarm
Breaker 2 cycle INS
Nack
Breaker 2 comm INS
Ack
Breaker 2 comm INS
Inactive
Breaker 2 controINS
Active
Breaker 2 controINS
Unsuccessfu Breaker 2 comm CMS

14108
14109
14109
14110
14110
14111
14111
14112
14112
14113

122
122
122
122
122
122
122
122
122
122
122
122
122
122
122
122
122
122
122
122
122
122
122
122
122

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11
E12
E13
E14
E15
E16
E17
E18
E19
E24
E25
E26
E27
E28

EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_1BIT
EV_1BIT
EV_1BIT
EV_1BIT
EV_1BIT
EV_1BIT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_1BIT
EV_1BIT
EV_NODAT
Default ma

1
2
4
8
16
32
64
128
256
512
1024
2048
4096
8192
16384
32768
65536
131072
262144
524288
16777216
33554432
67108864
134217728
268435456
134917887

1
1
1
1
1
1
1
1
0
1
1
1
0
1
0
1
0
1
0
1
0
0
0
1
0

0
0
0
0
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11

1
0
0
0
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0

F122V001
F122V001
F122V001
F122V001
F122V031
F122V031
F122V030
F122V030
F122V034
F122V034
F122O003
F122O003
F122O004
F122O004
F122V035
F122V035
-

Open (10)
Close (01)
Faulty (11)
Middle (00)
Enabled
Disabled
Enabled
Disabled
Inactive
Active
Completed
Started
Deactivated
Activated
Deactivated
Activated
Normal
Alarm
Normal
Alarm
Nack
Ack
Inactive
Active
Unsuccesful

Disconnector 1 pPOS
Disconnector 1 pPOS
Disconnector 1 pPOS
Disconnector 1 pPOS
Disconnector 1 oINS
Disconnector 1 oINS
Disconnector 1 cINS
Disconnector 1 cINS
Disconnector 1 i INS
Disconnector 1 i INS
Disconnector 1 cINS
Disconnector 1 cINS
Disconnector 1 oINS
Disconnector 1 oINS
Disconnector 1 cINS
Disconnector 1 cINS
Disconnector 1 oINS
Disconnector 1 oINS
Disconnector 1 cINS
Disconnector 1 cINS
Disconnector 1 cCMS
Disconnector 1 cCMS
Disconnector 1 cBLK
Disconnector 1 cBLK
Disconnector 1 cCMS

14200
14200
14200
14200
14201
14201
14202
14202
14203
14203
14204
14204
14205
14205
14206
14206
14207
14207
14208
14208
14209
14209
14210
14210
14211

123
123
123
123
123
123
123

E0
E1
E2
E3
E4
E5
E6

EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_1BIT
EV_1BIT
EV_1BIT

1
2
4
8
16
32
64

1
1
1
1
1
1
1

0
0
0
0
1
1
2

1
0
0
0
1
0
1

F123V001
F123V001
F123V001
F123V001
F123V031
F123V031
F123V030

Open (10)
Close (01)
Faulty (11)
Middle (00)
Enabled
Disabled
Enabled

Disconnector 2 pPOS
Disconnector 2 pPOS
Disconnector 2 pPOS
Disconnector 2 pPOS
Disconnector 2 oINS
Disconnector 2 oINS
Disconnector 2 cINS

14300
14300
14300
14300
14301
14301
14302

*/

*/

ABB Oy Distribution Automation

/* 100124 / Rev B CODC3

Event List for RET 545

January 20 2005

123
123
123
123
123
123
123
123
123
123
123
123
123
123
123
123
123
123

E7
E8
E9
E10
E11
E12
E13
E14
E15
E16
E17
E18
E19
E24
E25
E26
E27
E28

EV_1BIT
EV_1BIT
EV_1BIT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_1BIT
EV_1BIT
EV_NODAT
Default ma

128
256
512
1024
2048
4096
8192
16384
32768
65536
131072
262144
524288
16777216
33554432
67108864
134217728
268435456
134917887

1
0
1
1
1
0
1
0
1
0
1
0
1
0
0
0
1
0

2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0

F123V030
F123V034
F123V034
F123O003
F123O003
F123O004
F123O004
F123V035
F123V035
-

Disabled
Inactive
Active
Completed
Started
Deactivated
Activated
Deactivated
Activated
Normal
Alarm
Normal
Alarm
Nack
Ack
Inactive
Active
Unsuccesful

Disconnector 2 cINS
Disconnector 2 i INS
Disconnector 2 i INS
Disconnector 2 cINS
Disconnector 2 cINS
Disconnector 2 oINS
Disconnector 2 oINS
Disconnector 2 cINS
Disconnector 2 cINS
Disconnector 2 oINS
Disconnector 2 oINS
Disconnector 2 cINS
Disconnector 2 cINS
Disconnector 2 cCMS
Disconnector 2 cCMS
Disconnector 2 cBLK
Disconnector 2 cBLK
Disconnector 2 cCMS

14302
14303
14303
14304
14304
14305
14305
14306
14306
14307
14307
14308
14308
14309
14309
14310
14310
14311

124
124
124
124
124
124
124
124
124
124
124
124
124
124
124
124
124
124
124
124
124
124
124
124
124

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11
E12
E13
E14
E15
E16
E17
E18
E19
E24
E25
E26
E27
E28

EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_1BIT
EV_1BIT
EV_1BIT
EV_1BIT
EV_1BIT
EV_1BIT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_1BIT
EV_1BIT
EV_NODAT
Default ma

1
2
4
8
16
32
64
128
256
512
1024
2048
4096
8192
16384
32768
65536
131072
262144
524288
16777216
33554432
67108864
134217728
268435456
134917887

1
1
1
1
1
1
1
1
0
1
1
1
0
1
0
1
0
1
0
1
0
0
0
1
0

0
0
0
0
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11

1
0
0
0
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0

F124V001
F124V001
F124V001
F124V001
F124V031
F124V031
F124V030
F124V030
F124V034
F124V034
F124O003
F124O003
F124O004
F124O004
F124V035
F124V035
-

Open (10)
Close (01)
Faulty (11)
Middle (00)
Enabled
Disabled
Enabled
Disabled
Inactive
Active
Completed
Started
Deactivated
Activated
Deactivated
Activated
Normal
Alarm
Normal
Alarm
Nack
Ack
Inactive
Active
Unsuccesful

Disconnector 3 pPOS
Disconnector 3 pPOS
Disconnector 3 pPOS
Disconnector 3 pPOS
Disconnector 3 oINS
Disconnector 3 oINS
Disconnector 3 cINS
Disconnector 3 cINS
Disconnector 3 i INS
Disconnector 3 i INS
Disconnector 3 cINS
Disconnector 3 cINS
Disconnector 3 oINS
Disconnector 3 oINS
Disconnector 3 cINS
Disconnector 3 cINS
Disconnector 3 oINS
Disconnector 3 oINS
Disconnector 3 cINS
Disconnector 3 cINS
Disconnector 3 cCMS
Disconnector 3 cCMS
Disconnector 3 cBLK
Disconnector 3 cBLK
Disconnector 3 cCMS

14400
14400
14400
14400
14401
14401
14402
14402
14403
14403
14404
14404
14405
14405
14406
14406
14407
14407
14408
14408
14409
14409
14410
14410
14411

*/

ABB Oy Distribution Automation

/* 100125 / Rev B CODC4

/* 100126 / Rev B CODC5

Event List for RET 545

January 20 2005

*/
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11
E12
E13
E14
E15
E16
E17
E18
E19
E24
E25
E26
E27
E28

EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_1BIT
EV_1BIT
EV_1BIT
EV_1BIT
EV_1BIT
EV_1BIT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_1BIT
EV_1BIT
EV_NODAT
Default ma

1
2
4
8
16
32
64
128
256
512
1024
2048
4096
8192
16384
32768
65536
131072
262144
524288
16777216
33554432
67108864
134217728
268435456
134917887

1
1
1
1
1
1
1
1
0
1
1
1
0
1
0
1
0
1
0
1
0
0
0
1
0

0
0
0
0
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11

1
0
0
0
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0

F125V001
F125V001
F125V001
F125V001
F125V031
F125V031
F125V030
F125V030
F125V034
F125V034
F125O003
F125O003
F125O004
F125O004
F125V035
F125V035
-

Open (10)
Close (01)
Faulty (11)
Middle (00)
Enabled
Disabled
Enabled
Disabled
Inactive
Active
Completed
Started
Deactivated
Activated
Deactivated
Activated
Normal
Alarm
Normal
Alarm
Nack
Ack
Inactive
Active
Unsuccesful

Disconnector 4 pPOS
Disconnector 4 pPOS
Disconnector 4 pPOS
Disconnector 4 pPOS
Disconnector 4 oINS
Disconnector 4 oINS
Disconnector 4 cINS
Disconnector 4 cINS
Disconnector 4 i INS
Disconnector 4 i INS
Disconnector 4 cINS
Disconnector 4 cINS
Disconnector 4 oINS
Disconnector 4 oINS
Disconnector 4 cINS
Disconnector 4 cINS
Disconnector 4 oINS
Disconnector 4 oINS
Disconnector 4 cINS
Disconnector 4 cINS
Disconnector 4 cCMS
Disconnector 4 cCMS
Disconnector 4 cBLK
Disconnector 4 cBLK
Disconnector 4 cCMS

14500
14500
14500
14500
14501
14501
14502
14502
14503
14503
14504
14504
14505
14505
14506
14506
14507
14507
14508
14508
14509
14509
14510
14510
14511

126
126
126
126
126
126
126
126
126
126
126
126
126
126
126
126
126
126

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11
E12
E13
E14
E15
E16
E17

EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_1BIT
EV_1BIT
EV_1BIT
EV_1BIT
EV_1BIT
EV_1BIT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT

1
2
4
8
16
32
64
128
256
512
1024
2048
4096
8192
16384
32768
65536
131072

1
1
1
1
1
1
1
1
0
1
1
1
0
1
0
1
0
1

0
0
0
0
1
1
2
2
3
3
4
4
5
5
6
6
7
7

1
0
0
0
1
0
1
0
0
0
0
0
0
0
0
0
0
0

F126V001
F126V001
F126V001
F126V001
F126V031
F126V031
F126V030
F126V030
F126V034
F126V034
F126O003
F126O003

Open (10)
Close (01)
Faulty (11)
Middle (00)
Enabled
Disabled
Enabled
Disabled
Inactive
Active
Completed
Started
Deactivated
Activated
Deactivated
Activated
Normal
Alarm

Disconnector 5 pPOS
Disconnector 5 pPOS
Disconnector 5 pPOS
Disconnector 5 pPOS
Disconnector 5 oINS
Disconnector 5 oINS
Disconnector 5 cINS
Disconnector 5 cINS
Disconnector 5 i INS
Disconnector 5 i INS
Disconnector 5 cINS
Disconnector 5 cINS
Disconnector 5 oINS
Disconnector 5 oINS
Disconnector 5 cINS
Disconnector 5 cINS
Disconnector 5 oINS
Disconnector 5 oINS

14600
14600
14600
14600
14601
14601
14602
14602
14603
14603
14604
14604
14605
14605
14606
14606
14607
14607

*/

ABB Oy Distribution Automation

/* 100127 / Rev B COIND1

/* 100128 / Rev B COIND2

/* 100129 / Rev B COIND3

/* 100130 / Rev B COIND4

/* 100131 / Rev B COIND5

Event List for RET 545

January 20 2005

126
126
126
126
126
126
126

E18
E19
E24
E25
E26
E27
E28

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_1BIT
EV_1BIT
EV_NODAT
Default ma

262144
524288
16777216
33554432
67108864
134217728
268435456
134917887

0
1
0
0
0
1
0

8
8
9
9
10
10
11

0
0
0
0
1
0
0

F126O004
F126O004
F126V035
F126V035
-

Normal
Alarm
Nack
Ack
Inactive
Active
Unsuccesful

Disconnector 5 cINS
Disconnector 5 cINS
Disconnector 5 cCMS
Disconnector 5 cCMS
Disconnector 5 cBLK
Disconnector 5 cBLK
Disconnector 5 cCMS

14608
14608
14609
14609
14610
14610
14611

127
127
127
127
127
127

E0
E1
E2
E3
E8
E9

EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_1BIT
EV_1BIT
Default ma

1
2
4
8
256
512
527

1
1
1
1
0
1

0
0
0
0
1
1

1
0
0
0
0
0

F127V001
F127V001
F127V001
F127V001
F127V034
F127V034

Open (10)
Close (01)
Faulty (11)
Middle (00)
Inactive
Active

Indication 1 posi POS


Indication 1 posi POS
Indication 1 posi POS
Indication 1 posi POS
Indication 1 inva INS
Indication 1 inva INS

14700
14700
14700
14700
14701
14701

128
128
128
128
128
128

E0
E1
E2
E3
E8
E9

EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_1BIT
EV_1BIT
Default ma

1
2
4
8
256
512
527

1
1
1
1
0
1

0
0
0
0
1
1

1
0
0
0
0
0

F128V001
F128V001
F128V001
F128V001
F128V034
F128V034

Open (10)
Close (01)
Faulty (11)
Middle (00)
Inactive
Active

Indication 2 posi POS


Indication 2 posi POS
Indication 2 posi POS
Indication 2 posi POS
Indication 2 inva INS
Indication 2 inva INS

14800
14800
14800
14800
14801
14801

129
129
129
129
129
129

E0
E1
E2
E3
E8
E9

EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_1BIT
EV_1BIT
Default ma

1
2
4
8
256
512
527

1
1
1
1
0
1

0
0
0
0
1
1

1
0
0
0
0
0

F129V001
F129V001
F129V001
F129V001
F129V034
F129V034

Open (10)
Close (01)
Faulty (11)
Middle (00)
Inactive
Active

Indication 3 posi POS


Indication 3 posi POS
Indication 3 posi POS
Indication 3 posi POS
Indication 3 inva INS
Indication 3 inva INS

14900
14900
14900
14900
14901
14901

130
130
130
130
130
130

E0
E1
E2
E3
E8
E9

EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_1BIT
EV_1BIT
Default ma

1
2
4
8
256
512
527

1
1
1
1
0
1

0
0
0
0
1
1

1
0
0
0
0
0

F130V001
F130V001
F130V001
F130V001
F130V034
F130V034

Open (10)
Close (01)
Faulty (11)
Middle (00)
Inactive
Active

Indication 4 posi POS


Indication 4 posi POS
Indication 4 posi POS
Indication 4 posi POS
Indication 4 inva INS
Indication 4 inva INS

15000
15000
15000
15000
15001
15001

131
131
131
131
131

E0
E1
E2
E3
E8

EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_1BIT

1
2
4
8
256

1
1
1
1
0

0
0
0
0
1

1
0
0
0
0

F131V001
F131V001
F131V001
F131V001
F131V034

Open (10)
Close (01)
Faulty (11)
Middle (00)
Inactive

Indication 5 posi POS


Indication 5 posi POS
Indication 5 posi POS
Indication 5 posi POS
Indication 5 inva INS

15100
15100
15100
15100
15101

*/

*/

*/

*/

*/

ABB Oy Distribution Automation

/* 100132 / Rev B COIND6

/* 100133 / Rev B COIND7

/* 100134 / Rev B COIND8

/* 100135 / Rev B COSW1

/* 100136 / Rev B COSW2

/* 100137 / Rev B COSW3

/* 100138 / Rev B COSW4

/* 100139 / Rev B CO3DC1

Event List for RET 545

January 20 2005

131 E9

EV_1BIT
Default ma

512
527

0 F131V034 Active

Indication 5 inva INS

15101

132
132
132
132
132
132

E0
E1
E2
E3
E8
E9

EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_1BIT
EV_1BIT
Default ma

1
2
4
8
256
512
527

1
1
1
1
0
1

0
0
0
0
1
1

1
0
0
0
0
0

F132V001
F132V001
F132V001
F132V001
F132V034
F132V034

Open (10)
Close (01)
Faulty (11)
Middle (00)
Inactive
Active

Indication 6 posi POS


Indication 6 posi POS
Indication 6 posi POS
Indication 6 posi POS
Indication 6 inva INS
Indication 6 inva INS

15200
15200
15200
15200
15201
15201

133
133
133
133
133
133

E0
E1
E2
E3
E8
E9

EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_1BIT
EV_1BIT
Default ma

1
2
4
8
256
512
527

1
1
1
1
0
1

0
0
0
0
1
1

1
0
0
0
0
0

F133V001
F133V001
F133V001
F133V001
F133V034
F133V034

Open (10)
Close (01)
Faulty (11)
Middle (00)
Inactive
Active

Indication 7 posi POS


Indication 7 posi POS
Indication 7 posi POS
Indication 7 posi POS
Indication 7 inva INS
Indication 7 inva INS

15300
15300
15300
15300
15301
15301

134
134
134
134
134
134

E0
E1
E2
E3
E8
E9

EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_1BIT
EV_1BIT
Default ma

1
2
4
8
256
512
527

1
1
1
1
0
1

0
0
0
0
1
1

1
0
0
0
0
0

F134V001
F134V001
F134V001
F134V001
F134V034
F134V034

Open (10)
Close (01)
Faulty (11)
Middle (00)
Inactive
Active

Indication 8 posi POS


Indication 8 posi POS
Indication 8 posi POS
Indication 8 posi POS
Indication 8 inva INS
Indication 8 inva INS

15400
15400
15400
15400
15401
15401

135 E0
135 E1

EV_1BIT
EV_1BIT
Default ma

1
2
3

1
1

0
0

1 F135V001 Off
0 F135V001 On

On/off object 1 p POS


On/off object 1 p POS

15500
15500

136 E0
136 E1

EV_1BIT
EV_1BIT
Default ma

1
2
3

1
1

0
0

1 F136V001 Off
0 F136V001 On

On/off object 2 p POS


On/off object 2 p POS

15600
15600

137 E0
137 E1

EV_1BIT
EV_1BIT
Default ma

1
2
3

1
1

0
0

1 F137V001 Off
0 F137V001 On

On/off object 3 p POS


On/off object 3 p POS

15700
15700

138 E0
138 E1

EV_1BIT
EV_1BIT
Default ma

1
2
3

1
1

0
0

1 F138V001 Off
0 F138V001 On

On/off object 4 p POS


On/off object 4 p POS

15800
15800

139 E0
139 E1
139 E2

EV_2BIT_1
EV_2BIT_1
EV_2BIT_1

1
2
4

1
1
1

0
0
0

1 F139V001 Open (10)


0 F139V001 Close (01)
0 F139V001 Faulty (11)

3-state sw. 1 posPOS


3-state sw. 1 posPOS
3-state sw. 1 posPOS

15900
15900
15900

*/

*/

*/

*/

*/

*/

*/

*/

ABB Oy Distribution Automation

/* 100140 / Rev B CO3DC2

Event List for RET 545

139
139
139
139
139
139
139
139
139
139
139
139
139
139
139
139
139
139
139
139
139
139
139
139

E3
E4
E5
E6
E7
E8
E9
E10
E11
E12
E13
E14
E15
E16
E17
E18
E19
E24
E25
E26
E27
E28
E30
E31

139
139
139
139
139
139
139
139
139
139
139
139
139
139

E32
E33
E34
E35
E36
E37
E38
E39
E40
E41
E42
E43
E44
E45

140
140
140
140
140

E0
E1
E2
E3
E4

January 20 2005

EV_2BIT_1
EV_1BIT
EV_1BIT
EV_1BIT
EV_1BIT
EV_1BIT
EV_1BIT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_1BIT
EV_1BIT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_2BIT_2
EV_2BIT_2
EV_2BIT_2
EV_2BIT_2
EV_1BIT
EV_1BIT
EV_1BIT
EV_1BIT
Default ma

8
16
32
64
128
256
512
1024
2048
4096
8192
16384
32768
65536
131072
262144
524288
16777216
33554432
67108864
134217728
268435456
1073741824
2147483648
2282401535
1
2
4
8
16
32
64
128
256
512
1024
2048
4096
8192
16362

1
1
1
1
1
0
1
1
1
0
1
0
1
0
1
0
1
0
0
0
1
0
0
1

0
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
12
12

0
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0

F139V001
F139V031
F139V031
F139V030
F139V030
F139V034
F139V034
F139O005
F139O005
F139O006
F139O006
F139V035
F139V035
-

Middle (00) 3-state sw. 1 posPOS


Enabled
3-state sw. 1 opeINS
Disabled
3-state sw. 1 opeINS
Enabled
3-state sw. 1 clo INS
Disabled
3-state sw. 1 clo INS
Inactive
3-state sw. 1 inv INS
Active
3-state sw. 1 inv INS
Completed 3-state sw. 1 comINS
Started
3-state sw. 1 comINS
Deactivated 3-state sw. 1 opeINS
Activated
3-state sw. 1 opeINS
Deactivated 3-state sw. 1 clo INS
Activated
3-state sw. 1 clo INS
Normal
3-state sw. 1 opeINS
Alarm
3-state sw. 1 opeINS
Normal
3-state sw. 1 clo INS
Alarm
3-state sw. 1 clo INS
Nack
3-state sw. 1 comINS
Ack
3-state sw. 1 comINS
Inactive
3-state sw. 1 comINS
Active
3-state sw. 1 comINS
Unsuccessfu 3-state sw. 1 comCMS
Deactivated 3-state sw. 1 earINS
Activated
3-state sw. 1 earINS

15900
15901
15901
15902
15902
15903
15903
15904
15904
15905
15905
15906
15906
15907
15907
15908
15908
15909
15909
15910
15910
15911
15912
15912

0
1
0
1
0
1
1
1
1
1
1
1
1
1

13
13
14
14
15
15
16
16
16
16
17
17
18
18

0
0
0
0
0
0
1
0
0
0
1
0
1
0

F139O007
F139O007
F139O008
F139O008
F139V002
F139V002
F139V002
F139V002
F139V032
F139V032
F139V033
F139V033

Deactivated
Activated
Normal
Alarm
Normal
Alarm
Free (10)
Earth (01)
Faulty (11)
Middle (00)
Enabled
Disabled
Enabled
Disabled

3-state sw. 1 freeINS


3-state sw. 1 freeINS
3-state sw. 1 earINS
3-state sw. 1 earINS
3-state sw. 1 freeINS
3-state sw. 1 freeINS
3-state sw. 1 posPOS
3-state sw. 1 posPOS
3-state sw. 1 posPOS
3-state sw. 1 posPOS
3-state sw. 1 earINS
3-state sw. 1 earINS
3-state sw. 1 freeINS
3-state sw. 1 freeINS

15913
15913
15914
15914
15915
15915
15916
15916
15916
15916
15917
15917
15918
15918

EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_2BIT_1
EV_1BIT

1
2
4
8
16

1
1
1
1
1

0
0
0
0
1

1
0
0
0
1

F140V001
F140V001
F140V001
F140V001
F140V031

Open (10)
Close (01)
Faulty (11)
Middle (00)
Enabled

3-state sw. 2 posPOS


3-state sw. 2 posPOS
3-state sw. 2 posPOS
3-state sw. 2 posPOS
3-state sw. 2 opeINS

16000
16000
16000
16000
16001

*/

ABB Oy Distribution Automation

/* 100141 / Rev C COCBDIR

/* 100142 / Rev B COLOCAT

Event List for RET 545

140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140

E5
E6
E7
E8
E9
E10
E11
E12
E13
E14
E15
E16
E17
E18
E19
E24
E25
E26
E27
E28
E30
E31

140
140
140
140
140
140
140
140
140
140
140
140
140
140

E32
E33
E34
E35
E36
E37
E38
E39
E40
E41
E42
E43
E44
E45

January 20 2005

EV_1BIT
EV_1BIT
EV_1BIT
EV_1BIT
EV_1BIT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_1BIT
EV_1BIT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_2BIT_2
EV_2BIT_2
EV_2BIT_2
EV_2BIT_2
EV_1BIT
EV_1BIT
EV_1BIT
EV_1BIT
Default ma

32
64
128
256
512
1024
2048
4096
8192
16384
32768
65536
131072
262144
524288
16777216
33554432
67108864
134217728
268435456
1073741824
2147483648
2282401535
1
2
4
8
16
32
64
128
256
512
1024
2048
4096
8192
16362

1
1
1
0
1
1
1
0
1
0
1
0
1
0
1
0
0
0
1
0
0
1

1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
12
12

0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0

F140V031
F140V030
F140V030
F140V034
F140V034
F140O005
F140O005
F140O006
F140O006
F140V035
F140V035
-

Disabled
3-state sw. 2 opeINS
Enabled
3-state sw. 2 clo INS
Disabled
3-state sw. 2 clo INS
Inactive
3-state sw. 2 inv INS
Active
3-state sw. 2 inv INS
Completed 3-state sw. 2 comINS
Started
3-state sw. 2 comINS
Deactivated 3-state sw. 2 opeINS
Activated
3-state sw. 2 opeINS
Deactivated 3-state sw. 2 clo INS
Activated
3-state sw. 2 clo INS
Normal
3-state sw. 2 opeINS
Alarm
3-state sw. 2 opeINS
Normal
3-state sw. 2 clo INS
Alarm
3-state sw. 2 clo INS
Nack
3-state sw. 2 comINS
Ack
3-state sw. 2 comINS
Inactive
3-state sw. 2 comINS
Active
3-state sw. 2 comINS
Unsuccessfu 3-state sw. 2 comCMS
Deactivated 3-state sw. 2 earINS
Activated
3-state sw. 2 earINS

16001
16002
16002
16003
16003
16004
16004
16005
16005
16006
16006
16007
16007
16008
16008
16009
16009
16010
16010
16011
16012
16012

0
1
0
1
0
1
1
1
1
1
1
1
1
1

13
13
14
14
15
15
16
16
16
16
17
17
18
18

0
0
0
0
0
0
1
0
0
0
1
0
1
0

F140O007
F140O007
F140O008
F140O008
F140V002
F140V002
F140V002
F140V002
F140V032
F140V032
F140V033
F140V033

Deactivated
Activated
Normal
Alarm
Normal
Alarm
Free (10)
Earth (01)
Faulty (11)
Middle (00)
Enabled
Disabled
Enabled
Disabled

3-state sw. 2 freeINS


3-state sw. 2 freeINS
3-state sw. 2 earINS
3-state sw. 2 earINS
3-state sw. 2 freeINS
3-state sw. 2 freeINS
3-state sw. 2 posPOS
3-state sw. 2 posPOS
3-state sw. 2 posPOS
3-state sw. 2 posPOS
3-state sw. 2 earINS
3-state sw. 2 earINS
3-state sw. 2 freeINS
3-state sw. 2 freeINS

16013
16013
16014
16014
16015
16015
16016
16016
16016
16016
16017
16017
16018
16018

141 E0
141 E1

EV_NODAT
EV_NODAT
Default ma

1
2
2

0
1

0
0

00-

Deactivated Breaker direct opCMS


Activated
Breaker direct opCMS

16100
16100

142 E0
142 E1

EV_1BIT
EV_1BIT
Default ma

1
2
2

0
1

0
0

0 F142V001 Inactive
0 F142V001 Active

*/

*/
Logic position seINS
Logic position seINS

16200
16200

ABB Oy Distribution Automation

/* 100144 / Rev A COLTC

Event List for RET 545

January 20 2005

*/
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144
144

/* 100162 / Rev C MMIALAR1

/* 100163 / Rev C MMIALAR2

/* 100164 / Rev C MMIALAR3

/* 100165 / Rev C MMIALAR4

E0
E1
E2
E3
E4
E5
E7
E8
E9
E10
E11
E12
E13
E14
E15
E16
E17
E18
E19
E20
E21
E22
E23
E25
E27
E29

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_INT16
EV_INT16
EV_INT16
EV_INT16
EV_NODAT
EV_INT16
EV_INT16
Default ma

1
2
4
8
16
32
128
256
512
1024
2048
4096
8192
16384
32768
65536
131072
262144
524288
1048576
2097152
4194304
8388608
33554432
134217728
536870912
708837120

0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
1
1
1

0
0
1
1
2
2
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
13
14

162 E0
162 E1
162 E3

EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
8
2

0
1
0

0
0
1

163 E0
163 E1
163 E3

EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
8
2

0
1
0

164 E0
164 E1
164 E3

EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
8
2

165 E0
165 E1

EV_NODAT
EV_NODAT

1
2

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
1
1

F144O005
F144O005
F144O007
F144O007
F144O006
F144O006
F144O012
F144O012
F144O013
F144O013
F144O014
F144O014
F144O016
F144O016
F144O015
F144O015
F144O017
F144O017
F144O020
F144O020
F144O009
F144I005

Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
Reset
Activated
-

Operation timer INS


Operation timer INS
Voltage raise ou INS
Voltage raise ou INS
Voltage lower ouINS
Voltage lower ouINS
RSV input changINS
Overcurrent blocBLK
Overcurrent blocBLK
Undervoltage bloBLK
Undervoltage bloBLK
Overvoltage blocBLK
Overvoltage blocBLK
High circ. curren BLK
High circ. curren BLK
External input bl BLK
External input bl BLK
Paralleling failureALA
Paralleling failureALA
Tap changer ala ALA
Tap changer ala ALA
Communication ALA
Communication ALA
TC already in ex ALA
Operation mode INS
TC position valu INS

16400
16400
16401
16401
16402
16402
16403
16404
16404
16405
16405
16406
16406
16407
16407
16408
16408
16409
16409
16410
16410
16411
16411
16412
16413
16414

1 F162I001 Inactive
0 F162I001 Active
0-

Alarm 1 status INS


Alarm 1 status INS
Alarm 1 acknowl INS

18200
18200
18201

0
0
1

1 F163I001 Inactive
0 F163I001 Active
0-

Alarm 2 status INS


Alarm 2 status INS
Alarm 2 acknowl INS

18300
18300
18301

0
1
0

0
0
1

1 F164I001 Inactive
0 F164I001 Active
0-

Alarm 3 status INS


Alarm 3 status INS
Alarm 3 acknowl INS

18400
18400
18401

0
1

0
0

1 F165I001 Inactive
0 F165I001 Active

Alarm 4 status
Alarm 4 status

18500
18500

*/

*/

*/

*/
INS
INS

ABB Oy Distribution Automation

Event List for RET 545

/* 100166 / Rev C MMIALAR5

/* 100185 / Rev B CMTIME2

/* 100186 / Rev B CMGAS1

8
2

0-

166 E0
166 E1
166 E3

EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
8
2

0
1
0

0
0
1

167 E0
167 E1
167 E3

EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
8
2

0
1
0

168 E0
168 E1
168 E3

EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
8
2

169 E0
169 E1
169 E3

EV_NODAT
EV_NODAT
EV_NODAT
Default ma

181 E0
181 E1

Alarm 4 acknowl INS

18501

1 F166I001 Inactive
0 F166I001 Active
0-

Alarm 5 status INS


Alarm 5 status INS
Alarm 5 acknowl INS

18600
18600
18601

0
0
1

1 F167I001 Inactive
0 F167I001 Active
0-

Alarm 6 status INS


Alarm 6 status INS
Alarm 6 acknowl INS

18700
18700
18701

0
1
0

0
0
1

1 F168I001 Inactive
0 F168I001 Active
0-

Alarm 7 status INS


Alarm 7 status INS
Alarm 7 acknowl INS

18800
18800
18801

1
2
8
2

0
1
0

0
0
1

1 F169I001 Inactive
0 F169I001 Active
0-

Alarm 8 status INS


Alarm 8 status INS
Alarm 8 acknowl INS

18900
18900
18901

EV_NODAT
EV_NODAT
Default ma

1
2
3

1
1

0
0

1 F181O001 Off
0 F181O001 On

Current input circALA


Current input circALA

20100
20100

182 E0
182 E1

EV_NODAT
EV_NODAT
Default ma

1
2
3

1
1

0
0

1 F182O001 Off
0 F182O001 On

Input voltage circALA


Input voltage circALA

20200
20200

184
184
184
184

E0
E1
E2
E3

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
10

0
1
0
1

0
0
1
1

1
0
0
0

F184O001
F184O001
F184I001
F184I001

Reset
Activated
Inactive
Active

Accumulated timALA
Accumulated timALA
Accumulated timINS
Accumulated timINS

20400
20400
20401
20401

185
185
185
185

E0
E1
E2
E3

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
10

0
1
0
1

0
0
1
1

1
0
0
0

F185O001
F185O001
F185I001
F185I001

Reset
Activated
Inactive
Active

Accumulated timALA
Accumulated timALA
Accumulated timINS
Accumulated timINS

20500
20500
20501
20501

186 E0
186 E1
186 E2

EV_NODAT
EV_NODAT
EV_NODAT

1
2
4

0
1
0

0
0
1

1 F186O001 Reset
0 F186O001 Activated
0 F186I001 Inactive

Low gas density ALA


Low gas density ALA
Low gas density ALA

20600
20600
20601

*/

/* 100169 / Rev C MMIALAR8

/* 100184 / Rev B CMTIME1

EV_NODAT
Default ma

*/

/* 100168 / Rev C MMIALAR7

/* 100182 / Rev D CMVO3

165 E3
*/

/* 100167 / Rev C MMIALAR6

/* 100181 / Rev C CMCU3

January 20 2005

*/

*/

*/

*/

*/

*/

ABB Oy Distribution Automation

Event List for RET 545

/* 100187 / Rev B CMBWEAR1

/* 100194 / Rev A CMGAS3

8
10

0 F186I001 Active

Low gas density ALA

20601

187 E0
187 E1

EV_NODAT
EV_NODAT
Default ma

1
2
2

0
1

0
0

1 F187O001 Reset
0 F187O001 Activated

Breaker 1 electri ALA


Breaker 1 electri ALA

20700
20700

188 E0
188 E1

EV_NODAT
EV_NODAT
Default ma

1
2
2

0
1

0
0

1 F188O001 Reset
0 F188O001 Activated

Breaker 2 electri ALA


Breaker 2 electri ALA

20800
20800

189 E0
189 E1

EV_NODAT
EV_NODAT
Default ma

1
2
2

0
1

0
0

1 F189O001 Reset
0 F189O001 Activated

Scheduled maintALA
Scheduled maintALA

20900
20900

190
190
190
190
190
190
190
190
190

E0
E1
E2
E3
E4
E5
E7
E8
E9

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
16
32
128
256
512
682

0
1
0
1
0
1
1
0
1

0
0
1
1
2
2
99
3
3

0
0
1
0
1
0
0
0
0

F190O002
F190O002
F190O003
F190O003
F190I002
F190I002

Inactive
Active
Reset
Activated
Reset
Activated
Activated
Uncharged
Charged

Spring 1 chargin INS


Spring 1 chargin INS
Spring 1 max ch ALA
Spring 1 max ch ALA
Spring 1 min chaALA
Spring 1 min chaALA
Spring 1 charge Spring 1 charge CMS
Spring 1 charge CMS

21000
21000
21001
21001
21002
21002
21099
21003
21003

191
191
191
191

E0
E1
E2
E3

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
10

0
1
0
1

0
0
1
1

1
0
0
0

F191O001
F191O001
F191I002
F191I002

Reset
Activated
Inactive
Active

Trip circuit superALA


Trip circuit superALA
Trip circuit superBLK
Trip circuit superBLK

21100
21100
21101
21101

192
192
192
192

E0
E1
E2
E3

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
10

0
1
0
1

0
0
1
1

1
0
0
0

F192O001
F192O001
F192I002
F192I002

Reset
Activated
Inactive
Active

Trip circuit superALA


Trip circuit superALA
Trip circuit superBLK
Trip circuit superBLK

21200
21200
21201
21201

193
193
193
193

E0
E1
E2
E3

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
4
8
10

0
1
0
1

0
0
1
1

1
0
1
0

F193O001
F193O001
F193O002
F193O002

Reset
Activated
Reset
Activated

Breaker 1 open tALA


Breaker 1 open tALA
Breaker 1 close ALA
Breaker 1 close ALA

21300
21300
21301
21301

194 E0
194 E1

EV_3BIT_1
EV_3BIT_1

1
2

0
1

0
0

1 F194O001 Reset
0 F194O001 Activated

Low gas density ALA


Low gas density ALA

21400
21400

*/

/* 100190 / Rev B CMSPRC1

/* 100193 / Rev B CMTRAV1

EV_NODAT
Default ma

*/

/* 100189 / Rev C CMSCHED

/* 100192 / Rev B CMTCS2

186 E3
*/

/* 100188 / Rev B CMBWEAR2

/* 100191 / Rev B CMTCS1

January 20 2005

*/

*/

*/

*/

*/

ABB Oy Distribution Automation

/* 100200 / Rev D MECU3A

/* 100201 / Rev D MECU1A

/* 100202 / Rev C MECU3B

Event List for RET 545

January 20 2005

194
194
194
194
194
194

E2
E3
E4
E5
E6
E7

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

4
8
16
32
64
128
170

0
1
0
1
0
1

1
1
2
2
3
3

0
0
0
0
0
0

F194I001
F194I001
F194I002
F194I002
F194I003
F194I003

Inactive
Active
Inactive
Active
Inactive
Active

Low gas density ALA


Low gas density ALA
Low gas density ALA
Low gas density ALA
Low gas density ALA
Low gas density ALA

21401
21401
21402
21402
21403
21403

200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11
E12
E13
E14
E15
E16
E17
E18
E19
E20
E21
E22
E23
E25
E27
E29

EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
Default ma

1
2
4
8
16
32
64
128
256
512
1024
2048
4096
8192
16384
32768
65536
131072
262144
524288
1048576
2097152
4194304
8388608
33554432
134217728
536870912
0

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

1
1
2
2
3
3
1
1
2
2
3
3
1
1
2
2
3
3
1
1
2
2
3
3
1
2
3

1
0
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

F200I001
F200I001
F200I002
F200I002
F200I003
F200I003
F200I001
F200I001
F200I002
F200I002
F200I003
F200I003
F200I001
F200I001
F200I002
F200I002
F200I003
F200I003
F200I001
F200I001
F200I002
F200I002
F200I003
F200I003
F200I001
F200I002
F200I003

High warning IL1


High warning IL1
High warning IL2
High warning IL2
High warning IL3
High warning IL3
High alarm reIL1
High alarm acIL1
High alarm reIL2
High alarm acIL2
High alarm reIL3
High alarm acIL3
Low warning IL1
Low warning IL1
Low warning IL2
Low warning IL2
Low warning IL3
Low warning IL3
Low alarm re IL1
Low alarm acIL1
Low alarm re IL2
Low alarm acIL2
Low alarm re IL3
Low alarm acIL3
Delta
IL1
Delta
IL2
Delta
IL3

CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR

22001
22001
22002
22002
22003
22003
22001
22001
22002
22002
22003
22003
22001
22001
22002
22002
22003
22003
22001
22001
22002
22002
22003
22003
22001
22002
22003

201
201
201
201
201

E0
E1
E2
E3
E5

EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
Default ma

1
2
4
8
32
0

0
0
0
0
0

1
1
1
1
1

1
0
0
0
0

F201I001
F201I001
F201I001
F201I001
F201I001

High warning Io
High warning Io
High alarm reIo
High alarm acIo
Delta
Io

CUR
CUR
CUR
CUR
CUR

22101
22101
22101
22101
22101

202 E0
202 E1

EV_FLOAT
EV_FLOAT

1
2

0
0

1
1

1 F202I001 High warning IL1


0 F202I001 High warning IL1

CUR
CUR

22201
22201

*/

*/

*/

ABB Oy Distribution Automation

/* 100203 / Rev D MECU1B

/* 100204 / Rev E MEVO3A

Event List for RET 545

January 20 2005

202
202
202
202
202
202
202
202
202
202
202
202
202
202
202
202
202
202
202
202
202
202
202
202
202

E2
E3
E4
E5
E6
E7
E8
E9
E10
E11
E12
E13
E14
E15
E16
E17
E18
E19
E20
E21
E22
E23
E25
E27
E29

EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
Default ma

4
8
16
32
64
128
256
512
1024
2048
4096
8192
16384
32768
65536
131072
262144
524288
1048576
2097152
4194304
8388608
33554432
134217728
536870912
0

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

2
2
3
3
1
1
2
2
3
3
1
1
2
2
3
3
1
1
2
2
3
3
1
2
3

1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

F202I002
F202I002
F202I003
F202I003
F202I001
F202I001
F202I002
F202I002
F202I003
F202I003
F202I001
F202I001
F202I002
F202I002
F202I003
F202I003
F202I001
F202I001
F202I002
F202I002
F202I003
F202I003
F202I001
F202I002
F202I003

High warning IL2


High warning IL2
High warning IL3
High warning IL3
High alarm reIL1
High alarm acIL1
High alarm reIL2
High alarm acIL2
High alarm reIL3
High alarm acIL3
Low warning IL1
Low warning IL1
Low warning IL2
Low warning IL2
Low warning IL3
Low warning IL3
Low alarm re IL1
Low alarm acIL1
Low alarm re IL2
Low alarm acIL2
Low alarm re IL3
Low alarm acIL3
Delta
IL1
Delta
IL2
Delta
IL3

CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR
CUR

22202
22202
22203
22203
22201
22201
22202
22202
22203
22203
22201
22201
22202
22202
22203
22203
22201
22201
22202
22202
22203
22203
22201
22202
22203

203
203
203
203
203

E0
E1
E2
E3
E5

EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
Default ma

1
2
4
8
32
0

0
0
0
0
0

1
1
1
1
1

1
0
0
0
0

F203I001
F203I001
F203I001
F203I001
F203I001

High warning Io
High warning Io
High alarm reIo
High alarm acIo
Delta (LV)
Io

NCU
NCU
NCU
NCU
NCU

22301
22301
22301
22301
22301

204
204
204
204
204
204
204
204
204
204
204
204

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11

EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT

1
2
4
8
16
32
64
128
256
512
1024
2048

0
0
0
0
0
0
0
0
0
0
0
0

1
1
2
2
3
3
1
1
2
2
3
3

1
0
1
0
1
0
0
0
0
0
0
0

F204I001
F204I001
F204I002
F204I002
F204I003
F204I003
F204I001
F204I001
F204I002
F204I002
F204I003
F204I003

High warning UL1


High warning UL1
High warning UL2
High warning UL2
High warning UL3
High warning UL3
High alarm reUL1
High alarm acUL1
High alarm reUL2
High alarm acUL2
High alarm reUL3
High alarm acUL3

VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL

22401
22401
22402
22402
22403
22403
22401
22401
22402
22402
22403
22403

*/

*/

ABB Oy Distribution Automation

/* 100205 / Rev E MEVO1A

Event List for RET 545

204
204
204
204
204
204
204
204
204
204
204
204
204
204
204

E12
E13
E14
E15
E16
E17
E18
E19
E20
E21
E22
E23
E25
E27
E29

204
204
204
204
204
204
204
204
204
204
204
204
204
204
204
204
204
204
204
204
204
204
204
204
204
204
204

E32
E33
E34
E35
E36
E37
E38
E39
E40
E41
E42
E43
E44
E45
E46
E47
E48
E49
E50
E51
E52
E53
E54
E55
E57
E59
E61

January 20 2005

EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
Default ma
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
Default ma

4096
8192
16384
32768
65536
131072
262144
524288
1048576
2097152
4194304
8388608
33554432
134217728
536870912
0
1
2
4
8
16
32
64
128
256
512
1024
2048
4096
8192
16384
32768
65536
131072
262144
524288
1048576
2097152
4194304
8388608
33554432
134217728
536870912
0

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

1
1
2
2
3
3
1
1
2
2
3
3
1
2
3

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

F204I001
F204I001
F204I002
F204I002
F204I003
F204I003
F204I001
F204I001
F204I002
F204I002
F204I003
F204I003
F204I001
F204I002
F204I003

Low warning UL1


Low warning UL1
Low warning UL2
Low warning UL2
Low warning UL3
Low warning UL3
Low alarm re UL1
Low alarm acUL1
Low alarm re UL2
Low alarm acUL2
Low alarm re UL3
Low alarm acUL3
Delta
UL1
Delta
UL2
Delta
UL3

VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL

22401
22401
22402
22402
22403
22403
22401
22401
22402
22402
22403
22403
22401
22402
22403

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

4
4
5
5
6
6
4
4
5
5
6
6
4
4
5
5
6
6
4
4
5
5
6
6
4
5
6

1
0
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

F204I001
F204I001
F204I002
F204I002
F204I003
F204I003
F204I001
F204I001
F204I002
F204I002
F204I003
F204I003
F204I001
F204I001
F204I002
F204I002
F204I003
F204I003
F204I001
F204I001
F204I002
F204I002
F204I003
F204I003
F204I001
F204I002
F204I003

High warning U12


High warning U12
High warning U23
High warning U23
High warning U31
High warning U31
High alarm reU12
High alarm acU12
High alarm reU23
High alarm acU23
High alarm reU31
High alarm acU31
Low warning U12
Low warning U12
Low warning U23
Low warning U23
Low warning U31
Low warning U31
Low alarm re U12
Low alarm acU12
Low alarm re U23
Low alarm acU23
Low alarm re U31
Low alarm acU31
Delta
U12
Delta
U23
Delta
U31

VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL

22404
22404
22405
22405
22406
22406
22404
22404
22405
22405
22406
22406
22404
22404
22405
22405
22406
22406
22404
22404
22405
22405
22406
22406
22404
22405
22406

EV_FLOAT

1 F205I001 High warning Uo

VOL

22501

*/
205 E0

ABB Oy Distribution Automation

/* 100206 / Rev C MEVO3B

Event List for RET 545

January 20 2005

205
205
205
205

E1
E2
E3
E5

EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
Default ma

2
4
8
32
0

0
0
0
0

1
1
1
1

0
0
0
0

F205I001
F205I001
F205I001
F205I001

High warning Uo
High alarm reUo
High alarm acUo
Delta
Uo

VOL
VOL
VOL
VOL

22501
22501
22501
22501

206
206
206
206
206
206
206
206
206
206
206
206
206
206
206
206
206
206
206
206
206
206
206
206
206
206
206

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11
E12
E13
E14
E15
E16
E17
E18
E19
E20
E21
E22
E23
E25
E27
E29

1
1
2
2
3
3
1
1
2
2
3
3
1
1
2
2
3
3
1
1
2
2
3
3
1
2
3

1
0
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

F206I001
F206I001
F206I002
F206I002
F206I003
F206I003
F206I001
F206I001
F206I002
F206I002
F206I003
F206I003
F206I001
F206I001
F206I002
F206I002
F206I003
F206I003
F206I001
F206I001
F206I002
F206I002
F206I003
F206I003
F206I001
F206I002
F206I003

High warning UL1


High warning UL1
High warning UL2
High warning UL2
High warning UL3
High warning UL3
High alarm reUL1
High alarm acUL1
High alarm reUL2
High alarm acUL2
High alarm reUL3
High alarm acUL3
Low warning UL1
Low warning UL1
Low warning UL2
Low warning UL2
Low warning UL3
Low warning UL3
Low alarm re UL1
Low alarm acUL1
Low alarm re UL2
Low alarm acUL2
Low alarm re UL3
Low alarm acUL3
Delta
UL1
Delta
UL2
Delta
UL3

VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL

22601
22601
22602
22602
22603
22603
22601
22601
22602
22602
22603
22603
22601
22601
22602
22602
22603
22603
22601
22601
22602
22602
22603
22603
22601
22602
22603

E32
E33
E34
E35
E36
E37
E38
E39
E40
E41
E42
E43

1
2
4
8
16
32
64
128
256
512
1024
2048
4096
8192
16384
32768
65536
131072
262144
524288
1048576
2097152
4194304
8388608
33554432
134217728
536870912
0
1
2
4
8
16
32
64
128
256
512
1024
2048

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

206
206
206
206
206
206
206
206
206
206
206
206

EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
Default ma
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT

0
0
0
0
0
0
0
0
0
0
0
0

4
4
5
5
6
6
4
4
5
5
6
6

1
0
1
0
1
0
0
0
0
0
0
0

F206I001
F206I001
F206I002
F206I002
F206I003
F206I003
F206I001
F206I001
F206I002
F206I002
F206I003
F206I003

High warning U12


High warning U12
High warning U23
High warning U23
High warning U31
High warning U31
High alarm reU12
High alarm acU12
High alarm reU23
High alarm acU23
High alarm reU31
High alarm acU31

VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL

22604
22604
22605
22605
22606
22606
22604
22604
22605
22605
22606
22606

*/

ABB Oy Distribution Automation

/* 100207 / Rev F MEPE7

/* 100208 / Rev D MEFR1

Event List for RET 545

January 20 2005

206
206
206
206
206
206
206
206
206
206
206
206
206
206
206

E44
E45
E46
E47
E48
E49
E50
E51
E52
E53
E54
E55
E57
E59
E61

EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
Default ma

4096
8192
16384
32768
65536
131072
262144
524288
1048576
2097152
4194304
8388608
33554432
134217728
536870912
0

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

4
4
5
5
6
6
4
4
5
5
6
6
4
5
6

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

F206I001
F206I001
F206I002
F206I002
F206I003
F206I003
F206I001
F206I001
F206I002
F206I002
F206I003
F206I003
F206I001
F206I002
F206I003

Low warning U12


Low warning U12
Low warning U23
Low warning U23
Low warning U31
Low warning U31
Low alarm re U12
Low alarm acU12
Low alarm re U23
Low alarm acU23
Low alarm re U31
Low alarm acU31
Delta
U12
Delta
U23
Delta
U31

VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL

207
207
207
207
207
207
207
207
207
207
207
207
207
207
207
207
207
207
207
207
207
207
207
207

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11
E12
E13
E14
E15
E17
E19
E21
E23
E25
E27
E29
E31

EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
Default ma

1
2
4
8
16
32
64
128
256
512
1024
2048
4096
8192
16384
32768
131072
524288
2097152
8388608
33554432
134217728
536870912
2147483648
0

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

1
1
1
1
2
2
2
2
1
1
1
1
2
2
2
2
1
2
3
4
5
6
7
8

1
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0

F207I001
F207I001
F207I001
F207I001
F207I002
F207I002
F207I002
F207I002
F207I001
F207I001
F207I001
F207I001
F207I002
F207I002
F207I002
F207I002
F207I001
F207I002
F207I003
F207V414
F207V415
F207V416
F207V417

High warning P3
APW
High warning P3
APW
High alarm reP3
APW
High alarm acP3
APW
High warning Q3
RPW
High warning Q3
RPW
High alarm reQ3
RPW
High alarm acQ3
RPW
Low warning P3
APW
Low warning P3
APW
Low alarm re P3
APW
Low alarm acP3
APW
Low warning Q3
RPW
Low warning Q3
RPW
Low alarm re Q3
RPW
Low alarm acQ3
RPW
Delta
P3
APW
Delta
Q3
RPW
Delta
S3
TPW
Delta
DPF
DPF
Delta
Active energy RFE
Delta
Active reverse e RRE
Delta
Reactive energy AFE
Delta
Reactive reverseARE

EV_FLOAT
EV_FLOAT
EV_FLOAT

1
2
4

0
0
0

1
1
1

1 F208I001 High warning Frequency


0 F208I001 High warning Frequency
0 F208I001 High alarm reFrequency

22604
22604
22605
22605
22606
22606
22604
22604
22605
22605
22606
22606
22604
22605
22606

*/
22701
22701
22701
22701
22702
22702
22702
22702
22701
22701
22701
22701
22702
22702
22702
22702
22701
22702
22703
22704
22705
22706
22707
22708

*/
208 E0
208 E1
208 E2

FRQ
FRQ
FRQ

22801
22801
22801

ABB Oy Distribution Automation

/* 100213 / Rev B MEAI1

/* 100214 / Rev B MEAI2

/* 100215 / Rev B MEAI3

Event List for RET 545

January 20 2005

208
208
208
208
208
208

E3
E4
E5
E6
E7
E9

EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
Default ma

8
16
32
64
128
512
0

0
0
0
0
0
0

1
1
1
1
1
1

0
0
0
0
0
0

F208I001
F208I001
F208I001
F208I001
F208I001
F208I001

High alarm acFrequency


Low warning Frequency
Low warning Frequency
Low alarm re Frequency
Low alarm acFrequency
Delta
Frequency

FRQ
FRQ
FRQ
FRQ
FRQ
FRQ

22801
22801
22801
22801
22801
22801

213
213
213
213
213
213
213
213
213
213
213

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E11

EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
Default ma

1
2
4
8
16
32
64
128
256
512
2048
0

0
0
0
0
0
0
0
0
0
0
0

1
1
1
1
1
1
1
1
1
1
1

1
0
0
0
0
0
0
0
0
0
0

F213I001
F213I001
F213I001
F213I001
F213I001
F213I001
F213I001
F213I001
F213I001
F213I001
F213I001

High warning MEAI1 value


High warning MEAI1 value
High alarm reMEAI1 value
High alarm acMEAI1 value
Low warning MEAI1 value
Low warning MEAI1 value
Low alarm re MEAI1 value
Low alarm acMEAI1 value
Value is valid MEAI1 value
Value is inval MEAI1 value
Delta
MEAI1 value

VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL

23301
23301
23301
23301
23301
23301
23301
23301
23301
23301
23301

214
214
214
214
214
214
214
214
214
214
214

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E11

EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
Default ma

1
2
4
8
16
32
64
128
256
512
2048
0

0
0
0
0
0
0
0
0
0
0
0

1
1
1
1
1
1
1
1
1
1
1

1
0
0
0
0
0
0
0
0
0
0

F214I001
F214I001
F214I001
F214I001
F214I001
F214I001
F214I001
F214I001
F214I001
F214I001
F214I001

High warning MEAI2 value


High warning MEAI2 value
High alarm reMEAI2 value
High alarm acMEAI2 value
Low warning MEAI2 value
Low warning MEAI2 value
Low alarm re MEAI2 value
Low alarm acMEAI2 value
Value is valid MEAI2 value
Value is inval MEAI2 value
Delta
MEAI2 value

VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL

23401
23401
23401
23401
23401
23401
23401
23401
23401
23401
23401

215
215
215
215
215
215
215
215
215
215
215

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E11

EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
Default ma

1
2
4
8
16
32
64
128
256
512
2048
0

0
0
0
0
0
0
0
0
0
0
0

1
1
1
1
1
1
1
1
1
1
1

1
0
0
0
0
0
0
0
0
0
0

F215I001
F215I001
F215I001
F215I001
F215I001
F215I001
F215I001
F215I001
F215I001
F215I001
F215I001

High warning MEAI3 value


High warning MEAI3 value
High alarm reMEAI3 value
High alarm acMEAI3 value
Low warning MEAI3 value
Low warning MEAI3 value
Low alarm re MEAI3 value
Low alarm acMEAI3 value
Value is valid MEAI3 value
Value is inval MEAI3 value
Delta
MEAI3 value

VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL

23501
23501
23501
23501
23501
23501
23501
23501
23501
23501
23501

*/

*/

*/

ABB Oy Distribution Automation

/* 100216 / Rev B MEAI4

/* 100217 / Rev B MEAI5

/* 100218 / Rev B MEAI6

/* 100219 / Rev B MEAI7

Event List for RET 545

January 20 2005

*/
216
216
216
216
216
216
216
216
216
216
216

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E11

EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
Default ma

1
2
4
8
16
32
64
128
256
512
2048
0

0
0
0
0
0
0
0
0
0
0
0

1
1
1
1
1
1
1
1
1
1
1

1
0
0
0
0
0
0
0
0
0
0

F216I001
F216I001
F216I001
F216I001
F216I001
F216I001
F216I001
F216I001
F216I001
F216I001
F216I001

High warning MEAI4 value


High warning MEAI4 value
High alarm reMEAI4 value
High alarm acMEAI4 value
Low warning MEAI4 value
Low warning MEAI4 value
Low alarm re MEAI4 value
Low alarm acMEAI4 value
Value is valid MEAI4 value
Value is inval MEAI4 value
Delta
MEAI4 value

VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL

23601
23601
23601
23601
23601
23601
23601
23601
23601
23601
23601

217
217
217
217
217
217
217
217
217
217
217

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E11

EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
Default ma

1
2
4
8
16
32
64
128
256
512
2048
0

0
0
0
0
0
0
0
0
0
0
0

1
1
1
1
1
1
1
1
1
1
1

1
0
0
0
0
0
0
0
0
0
0

F217I001
F217I001
F217I001
F217I001
F217I001
F217I001
F217I001
F217I001
F217I001
F217I001
F217I001

High warning MEIA5 value


High warning MEAI5 value
High alarm reMEAI5 value
High alarm acMEAI5 value
Low warning MEAI5 value
Low warning MEAI5 value
Low alarm re MEAI5 value
Low alarm acMEAI5 value
Value is valid MEAI5 value
Value is inval MEAI5 value
Delta
MEAI5 value

VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL

23701
23701
23701
23701
23701
23701
23701
23701
23701
23701
23701

218
218
218
218
218
218
218
218
218
218
218

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E11

EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
Default ma

1
2
4
8
16
32
64
128
256
512
2048
0

0
0
0
0
0
0
0
0
0
0
0

1
1
1
1
1
1
1
1
1
1
1

1
0
0
0
0
0
0
0
0
0
0

F218I001
F218I001
F218I001
F218I001
F218I001
F218I001
F218I001
F218I001
F218I001
F218I001
F218I001

High warning MEAI6 value


High warning MEAI6 value
High alarm reMEAI6 value
High alarm acMEAI6 value
Low warning MEAI6 value
Low warning MEAI6 value
Low alarm re MEAI6 value
Low alarm acMEAI6 value
Value is valid MEAI6 value
Value is inval MEAI6 value
Delta
MEAI6 value

VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL

23801
23801
23801
23801
23801
23801
23801
23801
23801
23801
23801

219
219
219
219
219
219

E0
E1
E2
E3
E4
E5

EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT

1
2
4
8
16
32

0
0
0
0
0
0

1
1
1
1
1
1

1
0
0
0
0
0

F219I001
F219I001
F219I001
F219I001
F219I001
F219I001

High warning MEAI7 value


High warning MEAI7 value
High alarm reMEAI7 value
High alarm acMEAI7 value
Low warning MEAI7 value
Low warning MEAI7 value

VOL
VOL
VOL
VOL
VOL
VOL

23901
23901
23901
23901
23901
23901

*/

*/

*/

ABB Oy Distribution Automation

/* 100220 / Rev B MEAI8

Event List for RET 545

January 20 2005

219
219
219
219
219

E6
E7
E8
E9
E11

EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
Default ma

64
128
256
512
2048
0

0
0
0
0
0

1
1
1
1
1

0
0
0
0
0

F219I001
F219I001
F219I001
F219I001
F219I001

Low alarm re MEAI7 value


Low alarm acMEAI7 value
Value is valid MEAI7 value
Value is inval MEAI7 value
Delta
MEAI7 value

VOL
VOL
VOL
VOL
VOL

23901
23901
23901
23901
23901

220
220
220
220
220
220
220
220
220
220
220

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E11

EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
Default ma

1
2
4
8
16
32
64
128
256
512
2048
0

0
0
0
0
0
0
0
0
0
0
0

1
1
1
1
1
1
1
1
1
1
1

1
0
0
0
0
0
0
0
0
0
0

F220I001
F220I001
F220I001
F220I001
F220I001
F220I001
F220I001
F220I001
F220I001
F220I001
F220I001

High warning MEAI8 value


High warning MEAI8 value
High alarm reMEAI8 value
High alarm acMEAI8 value
Low warning MEAI8 value
Low warning MEAI8 value
Low alarm re MEAI8 value
Low alarm acMEAI8 value
Value is valid MEAI8 value
Value is inval MEAI8 value
Delta
MEAI8 value

VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL
VOL

24001
24001
24001
24001
24001
24001
24001
24001
24001
24001
24001

225
225
225
225
225

E0
E1
E3
E7
E31

EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
EV_NODAT
Default ma

1
2
8
128
2147483648
2147483787

1
1
1
1
1

0
0
1
4
3

0
0
0
0
0

Not full
Full
On
Failed
On

Recorder memo CMS


Recorder memo CMS
Overwrite of recoCMS
Manual trigger CMS
Recorder trigger INZ

24500
24500
24501
24504
24503

226
226
226
226
226

E0
E1
E2
E3
E5

EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
EV_FLOAT
Default ma

1
2
4
8
32
0

0
0
0
0
0

1
1
1
1
1

1
0
0
0
0

F226I001
F226I001
F226I001
F226I001
F226I001

High warning Uo
High warning Uo
High alarm reUo
High alarm acUo
Delta
Uo

VOL
VOL
VOL
VOL
VOL

24601
24601
24601
24601
24601

230
230
230
230
230
230
230
230
230
230
230
230

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11

EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230

1
2
4
8
16
32
64
128
256
512
1024
2048

0
0
0
0
0
0
0
0
0
0
0
0

0
0
1
1
2
2
3
3
4
4
5
5

0
0
0
0
0
0
0
0
0
0
0
0

E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11

INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS

25000
25000
25001
25001
25002
25002
25003
25003
25004
25004
25005
25005

*/

/* 100225 / Rev H MEDREC16

/* 100226 / Rev C MEVO1B

/* 100230 / Rev B EVENT230

*/

*/

*/
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event

ABB Oy Distribution Automation

Event List for RET 545

230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230

E12
E13
E14
E15
E16
E17
E18
E19
E20
E21
E22
E23
E24
E25
E26
E27
E28
E29
E30
E31

230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230

E32
E33
E34
E35
E36
E37
E38
E39
E40
E41
E42
E43
E44
E45
E46
E47
E48
E49
E50
E51
E52
E53
E54
E55
E56

EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
Default ma
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230

4096
8192
16384
32768
65536
131072
262144
524288
1048576
2097152
4194304
8388608
16777216
33554432
67108864
134217728
268435456
536870912
1073741824
2147483648
0
1
2
4
8
16
32
64
128
256
512
1024
2048
4096
8192
16384
32768
65536
131072
262144
524288
1048576
2097152
4194304
8388608
16777216

January 20 2005

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

E12
E13
E14
E15
E16
E17
E18
E19
E20
E21
E22
E23
E24
E25
E26
E27
E28
E29
E30
E31

Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event

INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS

25006
25006
25007
25007
25008
25008
25009
25009
25010
25010
25011
25011
25012
25012
25013
25013
25014
25014
25015
25015

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

16
16
17
17
18
18
19
19
20
20
21
21
22
22
23
23
24
24
25
25
26
26
27
27
28

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

E32
E33
E34
E35
E36
E37
E38
E39
E40
E41
E42
E43
E44
E45
E46
E47
E48
E49
E50
E51
E52
E53
E54
E55
E56

Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event

INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS
INS

25016
25016
25017
25017
25018
25018
25019
25019
25020
25020
25021
25021
25022
25022
25023
25023
25024
25024
25025
25025
25026
25026
25027
25027
25028

ABB Oy Distribution Automation

Event List for RET 545

230
230
230
230
230
230
230
/* CH231 / Rev B CH231

E57
E58
E59
E60
E61
E62
E63

EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
EVENT230
Default ma

January 20 2005

33554432
67108864
134217728
268435456
536870912
1073741824
2147483648
0

0
0
0
0
0
0
0

28
29
29
30
30
31
31

1
1

0
0
0
0
0
0
0

E57
E58
E59
E60
E61
E62
E63

Customer event
Customer event
Customer event
Customer event
Customer event
Customer event
Customer event

INS
INS
INS
INS
INS
INS
INS

25028
25029
25029
25030
25030
25031
25031

problem

LON communicaINS

25100

*/
231 E0

EV_NODAT
Default ma

0-

Vous aimerez peut-être aussi