Vous êtes sur la page 1sur 1

SPRINKLERS NOZZLE

WITHOUT BULB
SPRINKLER NOZZLE

PIPES TO BE SIZED BY FIRE


PROTECTION CONTRACTOR

PROVISION
CONDUIT FOR
INTERLOCK WIRE

240V AC SUPPLY(A)
(BY OTHERS)
SIREN

BMS
(BY OTHERS)
FIRE ALARM
PANEL

1ST STAGE PRDP


48.9 kg/h @ 1.5 BAR

GENERAL NOTES
1.
2.

GAS CONTROL PANEL


3.

6 BAR TO 0.7 BAR

4.
5.

VAPORIZER
TO BE CONNECTED
TO THE MAIN FIRE FIGHTING
PRESSURIZER WET LINE

6.

FILL POINT
MULTI VALVE

CHECK LOCK
TANK ACCESS

1ST STAGE PRDP

2ND STAGE PRDP


16.2 kg / hr @ 75 mm bar

7.

PIPE

LPG TANK
SECOND STAGE:
GATE VALVE
PRESSURE REGULATOR
WITH SOLENOID VALVE
(TYPICAL)

EARTHING

VENTILATION
LOUVER (TYP.)

This Drawing is not to be scaled.


All dimensions shown are in millimeters and do not take into
account applied finishes unless specifically indicated otherwise.
Any omissions or discrepancies found shall be reported to the
Architect / Engineer immediately.
Levels are given in meters to three decimal places above survey
datum.
This drawing is to be read in conjunction with the relevant section
of the specification and schedules.
The contractor shall submit full shop / setting out drawing for
approval (based on site dimensions) prior to commencement of
any site works, placing of orders, manufacture of fittings, fixtures
and components.
For External Finishes refer to Landscape Drawings and
Specifications.

KEY PLAN

PIPE

PIPE

PIPE

TO LABORATORIES

TO LABORATORIES

SV RV GV
37mm BAR
PIPE

PIPE

PIPE

PIPE

PIPE

ZONE-A

EMERGENCY STOP BUTTON


LINKED SOLENOID VALVE
FINAL LOCATION TBA

2ND STAGE PRESSURE


REDUCING STATION
FASTENED TO WALL (TYP.)

FINISH FLOOR LEVEL +0.480 = F.F.L. +8.40 ON SITE

ES

REVISIONS

LPG
37mm BAR

LPG PIPE EMBEDED


TO SCREED

EMERGENCY STOP
BUTTON LINKED TO
SOLENOID VALVE,
FINAL LOCATION TBA

PIPE
SV RV GV

SV RV GV

RUNNING INSIDE
CABINET

RUNNING INSIDE
CABINET

PIPE

SV RV GV

PIPE

SV RV GV

SV RV GV

ZONE-B

No. DATE

DESCRIPTION

C0

CONSTRUCTION ISSUE

15-06-15

BY
DA

PIPE

SV RV GV

SV RV GV

SV RV GV

PIPE

SV RV GV

PIPE

ES

LD

LD

ES

ES

LD

ES

LD

ES

LD

ES

LD

ES

LD

LD

ES

LD

ES
DESIGN ARCHITECTS & MEP ENGINEERS

EMBEDED
TO SCREED (TYP.)

LPG DISPENSER
(TYP.)

GAS LEAK DETECTOR


LINKED TO FIRE ALARM
AND SOLENOID VALVE
(TYP.)

Godwin Austen Johnson


Architects
STRUCTURAL ENGINEERS

LPG FILLING LINE


TO LPG TANK
OWNER

FORTES HOLDING
NOTES:
1.
2.
3.
4.

REFER TO FIRE FIGHTING DWG. NO. L59-105-1 FOR LPG


TANK PROTECTION.
ALL LPG PIPE RUNNING ON THE ROOF TO MOUNTED ON
200mm PLINTH.
ALL LPG PIPE RISING ON SHAFT SHALL BE VENTILATED.
ALL LPG PIPE RUNNING IN CORRIDOR SHALL BE PIPE IN
PIPE AND VENTILATED TO ATMOSPHERE.

ISSUED FOR

CONSTRUCTION
PROJECT

JVT SCHOOL
Plot No. JVT05SCP001
Jumeirah Village Triangle, Dubai, UAE
DRAWING TITLE

MECHANICAL SERVICES
GAS SCHEMATIC
REMOTE FILL
POINT

EMERGENCY
SHUTDOWN
STATION

EMERGENCY
SHUTDOWN
STATION
(BURIED)

Drawn
Date
Project No.

RT Checked
08.06.2014 Scale
Zone

3350
Authority Dwg. No.

EL Approved

OP

N.T.S. @ A1

Drawing No.

S54-900

Rev.

C0
Consecutive No.

This drawing, the designs and details shown are the copyright of
GODWIN AUSTEN JOHNSON and shall not be copied or reproduced in
any form without their written consent.
T +971 4 3237555 E mail@gaj-uae.ae
F +971 4 3237717 W www.gaj-uae.ae
PO Box 7185 Dubai United Arab Emirates

A1

Original Sheet FILE PATH : F:\- PROJECTS CURRENT\3350 - Fortes School\LIVE\ACAD\MEP DEPT\Sheet Files\Mechanical\54-Gas\3350-S54-900.dwg
Size

Vous aimerez peut-être aussi