Académique Documents
Professionnel Documents
Culture Documents
Description
Remedy
Startup error
- Check the fixing film connector. E000- The temperature detected by the main
Replace the fixing film unit. - Replace
0000 or sub thermistor does not rise to the
the DC controller PCB.
specified value during startup control.
Abnormally high temperature
(detected by main thermistor)
- Check the connector of the fixing film
E001The main thermistor detected an
unit. - Replace the fixing film unit. 0000
abnormally high temperature (240 deg Replace the DC controller PCB.
C) during temperature control.
Abnormally high temperature
(detected by sub thermistor)
- Check the connector of the fixing film
E001The sub thermistor detected an
unit. - Replace the fixing film unit. 0001
abnormally high temperature (295 deg Replace the DC controller PCB.
C) during temperature control.
Low temperature during temperature
- Check the connector of the fixing film
E002- control.
unit. - Replace the fixing film unit. 0000 The target temperature is not reached
Replace the DC controller PCB.
during temperature control.
Abnormally low temperature (detected
by main thermistor)
- Check the connector of the fixing film
E003- After the temperature detected by the
unit. - Replace the fixing film unit. 0000 main thermistor has reached the
Replace the DC controller PCB.
specified value, it does not reach the
specified value during initial rotation.
Abnormally low temperature (detected
by sub thermistor)
- Check the connector of the fixing film
E003- After the temperature detected by the
unit. - Replace the fixing film unit. 0001 sub thermistor has reached the
Replace the DC controller PCB.
specified value, it does not reach the
specified value during initial rotation.
E007- Fixing film sensor failure
0000 The fixing film sensor is faulty.
Code
Description
Remedy
0003
Code
Description
Remedy
0000
cassette
Disconnection of the optional cassette
was detected after power-on, detection
of normal connection to the optional
cassette, and start of communication.
incompatible.
Code
E8080000
Description
Fixing drive circuit failure
- The heater does not turn on. - A fixing drive motor failure was
detected.
Remedy