Académique Documents
Professionnel Documents
Culture Documents
Port
RI A-F
TN A
TN B
IDL
LMT A
LMT B
AUX
EC
GPS
Connector
SFP
RJ-45
SFP
HSIO
RJ-45
RJ-45
RJ-45
RJ-45
RJ-45
Description
Interface DU-RU (electrical) or DU-RRU (optical)
Gigabit Ethernet (electrical)
Gigabit Ethernet (optical)
Inter-DU link (DU to DU)
Serial port for OSE shell over RS-232
Fast Ethernet for O&M
Auxiliary (Common EC bus)
EC bus (Dedicated EC bus)
Used when the network synchronization source is a
GPS receiver
Hardware Overview
DUS41
Port Connect Description
or
A-F SFP
Radio Interface, 10Gbps/s
Interface DU-RU (electrical) or DU-RRU
(optical).
TN A RJ-45
Transport Network,
Gigabit Ethernet (electrical 1000BASET)
TN B SFP
Transport Network,
Gigabit Ethernet (optical SFP,
1000BASE-X)
TN C SFP
Transport Network,
Gigabit Ethernet (optical SFP,
1000BASE-X)
IDL HSIO
Inter-DU link (DU to DU)
COMPSFP
Coordinated Multi Point communication
(CoMP)
LMT RJ-45
Local Maintenance Terminal, ,
Fast Ethernet for local O&M
EC
RJ-45
EC bus (Dedicated EC bus)
Interface/protocol
Interface: Uu, Protocol: CPRI (proprietary)
C,D,E,F has also support for IDL2
Interface: S1,X2 and Mul
Link1
Interface: S1,X2 and Mul
Link2
Interface: S1,X2 and Mul
NOT USED AT YET
IDL1
NOT USED AT YET
Protocol: IP
Default enodeB IP: 169.254.1.10/24
Communication with SCU(Fan Control)
Hardware Overview
RU
Hardware Overview
Antenna System
AntennaSubUnit
Hardware Overview
DU-RU Connection
RfPort
AuPort
RiPort
S1
RU 1
S1
RI A
RRU 1
RU 2
RI A
RI B
DU
RI C
RU 3
RI D
RU 4
S2
DU
RI C
RRU 2
RI D
RI E
RI F
S2
RI B
RI E
RU 5
RU 6
S3
RI F
RRU 3
Checking command
1.hget riport remote: Check the interface connection between
DU and RU/RRU.
2. hget rfbranch portref: Check the interface connection between
S3
Hardware Overview
HW Alarm
Basic command:
1.Get:
Check the MO details: get xxx(MO name) xxxx(Attribute name)
Show the attribute value of all related MO: get . xxxx(Attribute name)
2.Set:
Change the attribute value of one MO: set xxx(MO name) xxxx(Attribute name)
Change all attribute of related MO: set . xxxx(Attribute name)
3. acl/acc:
List the action of one MO: acl xxx(MO name)
Start the action: acc xxx(MO name) xxxxx(action describtion from command acl)
4.pr & st:
List all related MO: pr XXX(MO name) For example: pr cellrelation (Check all cell
relations)
Check the status of MO: st xxx(MO name)
5.bl/deb
Block or Deblock the MO.
specificProblem
eventType
probableCause
Auto-Configuration EQUIPMENT_
of Board Not Possible ALARM
UNAVAILABLE
serviceImp
act
(CellDown,
CellAvailabi
perceive
lity = 0%)
dSeverit Manage (Y = Yes, N serviceDegrade
y
d Object = No)
(Y = Yes, N = No)
WARNIN
G
Slot
BatteryMissing
specificProblem
BatteryMissing
serviceImpact
(CellDown,
CellAvailability =
perceived Managed 0%)
serviceDegrade
eventType
probableCause
Severity Object
(Y = Yes, N = No) (Y = Yes, N = No)
PROCESSING_E CONFIGURATION_OR MAJOR
BatteryBa N
N
RROR_ALARM _CUSTOMIZING_ERR
ckup
OR
CurrentTooHigh
specificProblem
CurrentTooHigh
serviceImpact
(CellDown,
CellAvailability
perceive
= 0%)
dSeverit Managed (Y = Yes, N =
eventType
probableCause
y
Object
No)
EQUIPMENT_AL EQUIPMENT_MALFU
N
ARM
NCTION
MINOR
RfPort
serviceDegrade
(Y = Yes, N = No)
N
Disconnected
specificProblem
Disconnected
perceivedS Managed
eventType
probableCause
everity
Object
EQUIPMENT_ALAR EQUIPMENT_MALFUNCTI MAJOR
Cabinet
M
ON
serviceImpact
(CellDown,
CellAvailability =
0%)
(Y = Yes, N = No)
N
serviceDe
grade
(Y = Yes,
N = No)
N
Disconnected
EquipmentSup N
portFunction
Disconnected
ExternalNode
Disconnected
FanGroup
HwUnit
Disconnected
Disconnected
Disconnected
Actions for ExternalNode
1.Check that the number of the ExternalNode MO in the primary node is
consistent with the number of secondary nodes installed in the RBS.
2.If the alarm remains, check that the other nodes in the RBS are
configured as secondary nodes. The secondary nodes must have
attribute SupportSystemControl set to FALSE.
3.If the alarm remains, check that the attribute hubPosition on the EcPort
MO (of the ExternalNode MO) in this node has the same value as
attribute hubPosition on the HwUnit MO (of the PlugInUnit MO) in the
corresponding secondary node.
4.Check the cable to EC bus and restart DU or replace cable when needed.
Actions for FanGroup
1.Restart the System Control Unit/Support Part (SCU/SUP).
2.check that attribute climateSystem is correctly configured for this RBS
and that the corresponding correct number of fan groups is installed in
the RBS.
Disconnected
probableCause
serviceImpact
(CellDown,
CellAvailabilit
y = 0%)
perceived Managed (Y = Yes, N = serviceDegrade
Severity Object
No)
(Y = Yes, N = No)
specificProblem
eventType
EnclosureDoorOpen
ENVIRONMENT ENCLOSURE_DOOR_
AL_ALARM
OPEN_M3100
MAJOR
Cabinet
probableCause
serviceImpact
(CellDown,
CellAvailabilit
y = 0%)
perceived Managed (Y = Yes, N = serviceDegrade
Severity Object
No)
(Y = Yes, N = No)
specificProblem
eventType
FanFailure
EQUIPMENT_AL EQUIPMENT_MALFU
ARM
NCTION
MAJOR
FanGroup N
specificProblem
GeneralHwError
serviceImpact
(CellDown,
CellAvailabilit
y = 0%)
perceived Managed (Y = Yes, N = serviceDegrade
Severity Object
No)
(Y = Yes, N = No)
eventType
probableCause
EQUIPMENT_AL EQUIPMENT_MALFU
ARM
NCTION
MAJOR
HwUnit
specificProblem
Gigabit Ethernet Link
Redundancy Fault
serviceImpact
(CellDown,
CellAvailabilit
y = 0%)
perceived Managed (Y = Yes, N = serviceDegrade
eventType
probableCause
Severity Object
No)
(Y = Yes, N = No)
EQUIPMENT_AL REPLACEABLE_UNIT_
GigaBitEt
ARM
PROBLEM
WARNING hernet
N
N
HW Fault
perceivedS Managed
everity
Object
serviceDe
grade
(Y = Yes,
N = No)
specificProblem
eventType
HwFault
EQUIPMENT_ALAR EQUIPMENT_MALFUNCTI
M
ON
MINOR
AntennaNearU
nit
N
HwFault
EQUIPMENT_ALAR EQUIPMENT_MALFUNCTI
M
ON
MINOR
DeviceGroup
HwFault
EQUIPMENT_ALAR EQUIPMENT_MALFUNCTI
M
ON
MINOR
RiPort
probableCause
serviceImpact
(CellDown,
CellAvailability =
0%)
(Y = Yes, N = No)
HW Fault
LinkFailure
specificProblem
LinkFailure
eventType
probableCause
EQUIPMENT_
ALARM
LINK_FAILURE
serviceImpa
ct
(CellDown,
CellAvailabili
perceive
ty = 0%)
dSeverit Managed (Y = Yes, N serviceDegrade
y
Object
= No)
(Y = Yes, N = No)
MINOR
RiPort
Loss of Tracking
specificProblem
eventType
Loss of Tracking
EQUIPMENT_AL REPLACEABLE_UNIT_
ARM
PROBLEM
MAJOR
probableCause
serviceImpa
ct
(CellDown,
CellAvailabili
perceive
ty = 0%)
dSeverit Managed (Y = Yes, N serviceDegrade
y
Object
= No)
(Y = Yes, N = No)
Synchroni
Y
zation
Loss of Tracking
LossofMains
LossOfMains
perceived Managed
eventType
probableCause
Severity Object
ENVIRONMENTA COMMERCIAL_POWER
L_ALARM
_FAILURE
MAJOR
HwUnit
LossOfMains
ENVIRONMENTA COMMERCIAL_POWER
L_ALARM
_FAILURE
MAJOR
specificProblem
serviceD
serviceImpact
egrade
(CellDown,
CellAvailability = (Y = Yes,
N = No)
0%)
(Y = Yes, N = No)
N
PowerSupply N
No Contact
probableCause
perceived Managed
Severity Object
serviceD
serviceImpact
egrade
(CellDown,
CellAvailability = (Y = Yes,
N = No)
0%)
(Y = Yes, N = No)
specificProblem
eventType
NoContact
EQUIPMENT_ALAR EQUIPMENT_MALFUNCTI
M
ON
MINOR
AntennaNearU
nit
N
NoContact
PROCESSING_ERR CONFIGURATION_OR_CU
OR_ALARM
STOMIZING_ERROR
MINOR
AntennaNearU
nit
N
NoContact
EQUIPMENT_ALAR EQUIPMENT_MALFUNCTI
M
ON
MINOR
AuxPlugInUnit Y
No Contact
PowerFailure
specificProblem
PowerFailure
perceived
eventType
probableCause
Severity
EQUIPMENT_AL POWER_SUPPLY_FAILU
ARM
RE
MINOR
serviceD
serviceImpact
egrade
(CellDown,
CellAvailability = (Y = Yes,
N = No)
0%)
(Y = Yes, N = No)
Managed
Object
AuxPlugInUni
t
Y
RetFailure
probableCause
perceived Managed
Severity Object
specificProblem
eventType
RetFailure
EQUIPMENT_ALAR EQUIPMENT_MALFUNCTI
M
ON
MINOR
RetSubUnit
serviceD
serviceImpact
egrade
(CellDown,
CellAvailability = (Y = Yes,
N = No)
0%)
(Y = Yes, N = No)
N
VswrOverThreshold
probableCause
perceived Managed
Severity Object
specificProblem
eventType
VswrOverThreshold
EQUIPMENT_ALAR EQUIPMENT_MALFUNCTI
M
ON
MINOR
RfPort
serviceD
serviceImpact
egrade
(CellDown,
CellAvailability = (Y = Yes,
N = No)
0%)
(Y = Yes, N = No)
N
perceived Managed
Severity Object
serviceD
serviceImpact
egrade
(CellDown,
CellAvailability = (Y = Yes,
N = No)
0%)
(Y = Yes, N = No)
specificProblem
eventType
EQUIPMENT_ALAR
M
DISK_PROBLEM
MAJOR
ManagedElem
ent
N
EQUIPMENT_ALAR
M
DISK_PROBLEM
MAJOR
PlugInUnit
perceived Managed
Severity Object
serviceD
serviceImpact
egrade
(CellDown,
CellAvailability = (Y = Yes,
N = No)
0%)
(Y = Yes, N = No)
specificProblem
eventType
COMMUNICATION COMMUNICATION_PROT
S_ALARM
OCOL_ERROR
MAJOR
IpAccessHostEt Y
COMMUNICATION COMMUNICATION_PROT
S_ALARM
OCOL_ERROR
MAJOR
Ipv6Interface
perceived Managed
Severity Object
specificProblem
eventType
Emergency Unlock of
Software Licensing
QUALITY_OF_SER ALARM_INDICATION_SIG
VICE_ALARM
NAL
MINOR
Licensing
serviceD
serviceImpact
egrade
(CellDown,
CellAvailability = (Y = Yes,
N = No)
0%)
(Y = Yes, N = No)
N
ExternalAlarm
probableCause
perceived Managed
Severity Object
specificProblem
eventType
ExternalAlarm
UNKNOWN_EVEN EXTERNAL_EQUIPMENT_
T_TYPE
FAILURE
MINOR
AlarmPort
serviceD
serviceImpact
egrade
(CellDown,
CellAvailability = (Y = Yes,
N = No)
0%)
(Y = Yes, N = No)
N
ExternalLinkFailure
specificProblem
eventType
ExternalLinkFailure
EQUIPMENT_ALAR
M
LINK_FAILURE
probableCause
perceived Managed
Severity Object
MINOR
serviceD
serviceImpact
egrade
(CellDown,
CellAvailability = (Y = Yes,
N = No)
0%)
(Y = Yes, N = No)
ENodeBFunctio
n
N
FeatureResourceMissing
perceived Managed
Severity Object
specificProblem
eventType
FeatureResourceMissing
PROCESSING_ERR CONFIGURATION_OR_CU
OR_ALARM
STOMIZING_ERROR
MINOR
RfPort
FeatureResourceMissing
PROCESSING_ERR CONFIGURATION_OR_CU
OR_ALARM
STOMIZING_ERROR
MAJOR
SectorEquipme
ntFunction
Y
FeatureResourceMissing
PROCESSING_ERR CONFIGURATION_OR_CU
OR_ALARM
STOMIZING_ERROR
MAJOR
EUtranCellFDD Y
probableCause
serviceD
serviceImpact
egrade
(CellDown,
CellAvailability = (Y = Yes,
N = No)
0%)
(Y = Yes, N = No)
FeatureResourceMissing
eventType
probableCause
COMMUNICATION
S_ALARM
LOSS_OF_SIGNAL
perceived Managed
Severity Object
MAJOR
serviceD
serviceImpact
egrade
(CellDown,
CellAvailability = (Y = Yes,
N = No)
0%)
(Y = Yes, N = No)
GigaBitEtherne
t
N
InconsistentConfiguration
specificProblem
InconsistentConfigurati
on
InconsistentConfigurati
on
InconsistentConfigurati
on
InconsistentConfigurati
on
InconsistentConfigurati
on
InconsistentConfigurati
on
InconsistentConfigurati
on
eventType
perceived Managed
Severity Object
probableCause
CONFIGURATION_O
PROCESSING_ R_CUSTOMIZING_ER
ERROR_ALARM ROR
MINOR
CONFIGURATION_O
PROCESSING_ R_CUSTOMIZING_ER
ERROR_ALARM ROR
MINOR
CONFIGURATION_O
PROCESSING_ R_CUSTOMIZING_ER
ERROR_ALARM ROR
MINOR
CONFIGURATION_O
PROCESSING_ R_CUSTOMIZING_ER
ERROR_ALARM ROR
MINOR
CONFIGURATION_O
PROCESSING_ R_CUSTOMIZING_ER
ERROR_ALARM ROR
MINOR
CONFIGURATION_O
PROCESSING_ R_CUSTOMIZING_ER
ERROR_ALARM ROR
MAJOR
CONFIGURATION_O
PROCESSING_ R_CUSTOMIZING_ER
ERROR_ALARM ROR
MAJOR
CONFIGURATION_O
service
serviceImpact Degrad
e
(CellDown,
CellAvailability (Y =
Yes, N
= 0%)
= No)
(Y = Yes, N =
No)
AntennaUnit N
DeviceGrou
p
Y
RetSubUnit N
RfPort
RiPort
Y
SectorEquip
mentFunctio
n
Y
MbsfnArea
InconsistentConfiguration
Action for AntennaUnit:
This alarm is raised when the total tilt range of the antenna unit is modified,
there is no Remote Electrical Tilt (RET), and mechanicalAntennaTilt is out
of the total tilt range.
1.Change maximum or minimum total tilt or mechanicalAntennaTilt to get
total tilt within the maximum and minimum total tilt range
Action for DeviceGroup:
The Managed Object configuration of the unit is inconsistent. Either a
program is missing or the configuration is wrong.
1. Consult the next level of maintenance support to retrieve an Upgrade
Package with a correct Managed Object configuration
Action for RetSubUnit:
This alarm is raised when the total tilt range of the AntennaSubunit is modified, causing
the electricalAntennaTilt to be out of the total tilt range.
InconsistentConfiguration
InconsistentConfiguration
Action for MbsfnArea:
Inconsistent configuration of Mbsfn subframes. A cell is connected to several
Mbsfn areas. The subframes in these Mbsfn areas are overlapped.
1. Lock the MbsfnArea MO.
2.Check the configuration of subframes used by the MbsfnArea in the
attribute commonSFAlloc so that these do not overlap with subframes
used by another activated MbsfnArea.
3.Check the configuration of notificationIndicator so that it is not the same
as for another MbsfnArea that is activated in the same cell.
4.Unlock the MbsfnArea MO.
Action for SectorEquipmentFunction:
This alarm is raised because of, for example, an incorrect configuration of
how the hardware, such as antenna near products, or radio equipment,
are connected.
The alarm might be related to output power licenses. For example,
insufficient output power licenses are installed or there are hardwarerelated output power limitations.
1.Check if the hardware, such as antenna near products or radio equipment,
is correctly configured in the MOM. Modify the configuration if necessary.
2.Check if sufficient output power licenses are installed or if there are any
hardware-related output power limitations.
InconsistentConfiguration
Action for AlarmPort:
In mixed mode configurations, at external alarm port configuration, the
RBS System attempts to setup a physical alarm port on a Remote
Radio Unit (RRU) with a normallyOpen attribute that is different from
the shared client's value.
1.In the LTE node, lock the AlarmPort MO.
2.In the WCDMA node, lock the AlmDevice MO.
3.In the LTE node, set the normallyOpen attribute in the AlarmPort MO.
4.In the LTE node, unlock the AlarmPort MO.
5.In the WCDMA node, set the normallyOpen attribute in the AlmDevice
MO.
6.In the WCDMA node, unlock the AlmDevice MO.
Action for EcPort:
This alarm is raised if the hubposition is empty or not valid. Conflicting
values of hubposition also cause this alarm.
1.Check if the hubposition is given a proper value, that is, the value is
set to the port to which the hardware unit is connected to in the hub.
The hubposition value is not configured for any other EcPort MO.
eventType
perceived Managed
Severity Object
probableCause
CONFIGURATION_O
QUALITY_OF_S R_CUSTOMIZING_ER
ERVICE_ALARM ROR
CRITICAL Licensing
service
serviceImpact Degrad
e
(CellDown,
CellAvailability (Y =
Yes, N
= 0%)
= No)
(Y = Yes, N =
No)
eventType
COMMUNICATION
S_ALARM
UNAVAILABLE
probableCause
perceived Managed
Severity Object
service
serviceImpact Degrad
e
(CellDown,
CellAvailability (Y =
Yes, N
= 0%)
= No)
(Y = Yes, N =
No)
MAJOR
IpSyncRef
N
N
Reason of the alarm:
Communication problems toward NTP server, configuration fault or
HW fault.
Procedure of solving the alarm:
1. Examine the value of the attribute, ntpServerIpAddress, in the
MO, IpSyncRef(or Get . Ntpserveraddress to check the value)
2. Contact the NTP server, using the action, ping on the MO,
IpAccessHostEt
3. If there is no contact with the NTP server, contact the
maintenance center for that NTP server, or contact the
maintenance center for the network. Request them to act on the
fault. There can be a configuration fault in the network.
eventType
perceived Managed
Severity Object
probableCause
CONFIGURATION_O
QUALITY_OF_S R_CUSTOMIZING_ER
ERVICE_ALARM ROR
MINOR
serviceImpac service
Degrad
t
(CellDown, e
CellAvailabilit (Y =
Yes, N
y = 0%)
(Y = Yes, N = = No)
No)
specificProblem
Remote IP Address
Unreachable
eventType
probableCause
COMMUNICATI
ONS_ALARM
UNAVAILABLE
perceived Managed
Severity Object
serviceImpac service
Degrad
t
(CellDown, e
CellAvailabilit (Y =
Yes, N
y = 0%)
(Y = Yes, N = = No)
No)
N
ResourceConfigurationFailur
e
perceived Managed
Severity Object
specificProblem
eventType
probableCause
ResourceConfigurationF EQUIPMENT_A EQUIPMENT_MALFU
ailure
LARM
NCTION
MINOR
ResourceConfigurationF PROCESSING_ SYSTEM_CALL_UNS
ailure
ERROR_ALARM UCCESSFUL
MAJOR
ResourceConfigurationF PROCESSING_
ailure
ERROR_ALARM TIMEOUT_EXPIRED MAJOR
CONFIGURATION_O
ResourceConfigurationF PROCESSING_ R_CUSTOMIZING_ER
ailure
ERROR_ALARM ROR
MAJOR
ResourceConfigurationF PROCESSING_
ailure
ERROR_ALARM TIMEOUT_EXPIRED MAJOR
serviceImpac service
Degrad
t
(CellDown, e
CellAvailabilit (Y =
Yes, N
y = 0%)
(Y = Yes, N = = No)
No)
RetSubUnit
N
SectorEquipme
ntFunction
Y
SectorEquipme
ntFunction
Y
EUtranCellFDD Y
Y
Y
ResourceConfigurationFailur
e
ResourceConfigurationFailur
e
Action for EUtranCellFDD CONFIGURATION_OR_CUSTOMIZING_ERROR :
1. Check the EUtranCellFDD MO parameter values. Make sure configuraion is
correct.
2. Lock EUtranCellFDD and SectorEquipmentFunction, and unlock them.
Action for EUtranCellFDD TIMEOUT_EXPIRED:
The alarm is raised when activation of resources hangs or when the cell is
activated and the resource allocation for the cell fails. This can be caused by
a missing signal from the requested resource or by disabled (failed) resources
during startup of the node.
1. Lock and Unlock the cell using the EUtranCellFDD MO.Check ifthe alarm has
ceased.
2. If the alarm remains, check that the Digital Unit (DU) and RU is enabled and
unlocked.
4. If the DU is locked, unlock the DU.
5. If the RU is locked, unlock the RU.
6. Lock the cell using the EUtranCellFDD MO.
7. Unlock the cell.
8. If the alarm remains, restart the RU. See Restart Board.
8. Check that the alarm has ceased.
9. If the alarm remains, restart the node. See Restart Node.
10. Check that the alarm has ceased.
11. If the alarm remains, consult the next level of maintenance support.