Vous êtes sur la page 1sur 69

Internal

WCDMA BTS3900A
Hardware Structure

BTS3900AV200R010
www.huawei.com

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved


 As an important part of UTRAN,

NodeB mainly processes the signals of

the physical layer of Uu interface

 BTS3900A is a new generation which is

produced by Huawei Co. Ltd.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 2


Upon completion of this course, you will be able to:

 Master the hardware structure of BTS3900A

 Master the working principle of different subsystems and

boards of BTS3900A

 Master the cables connection rules of BTS3900A

 Know typical configurations of BTS3900A

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 3


 “BTS3900A Product Description”

 “BTS3900A Hardware Description”

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 4


BTS3900A Abbreviations
WMPT WCDMA Main Processing and Transmission Unit
WBBPa WCDMA Baseband Process unit Type A
WRFU WCDMA Radio Filter Unit
UBFA Universal BBU Fan Unit Type A (2U)
UEIU Universal Environment Interface unit
UELP Universal E1/T1 Lighting Protection unit
UFLP Universal FE/GE Lighting Protection unit
UPEU Universal Power and Environment Interface Unit
UTRP Universal Transmission Processing Unit
DCDU-01 Direct Current Distribution Unit-01
CPRI Common Protocol Radio Interface
PSU The power supply unit
PMU The power and environment monitoring unit
APM Advanced power module
APMI APM power monitor unit Interface board
AFMU APM fan monitor unit Interface board
FMUA fan environment monitoring unit
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 5
NodeB Position in UMTS Network
UE UTRAN CN
Uu Iu

Iu-CS
RNC
Iub
Iu-BC
CS
NodeB
b Iu-PS
Iu

Iur

NodeB PS
Iu-BC

Iub

NodeB
RNC
CBC

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 6


NodeB Location

Uu Interface

PSTN
UE TUP,ISUP ISDN
BTS3900A PSPDN
RNC

IU Interface
UE MSC/SGSN

M
AP
MAP
BTS3900A

BTS3900A HLR/AUC/EIR
SMC
UE
BTS3900A M2000

HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential Page 7


Chapter 1 NodeB Overview

Chapter 2 BTS3900A Hardware Structure

Chapter 3 BTS3900A Typical Configuration

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 8


Chapter 3 BTS3900A Hardware Structure

Section 1 BTS3900A Introduction

Section 2 Power Modules Structure

Section 3 Modules Structure

Section 4 Cables

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 9


BTS3900A Appearance

Type Parameters
Dimensions 600(W)*900(H)*450(D)

Weight under full ≤ 160Kg


configuration
3*1 and 3*2 Weight ≤ 120Kg
-48V input range of voltage -48V DC:-38.4V DC to -57V DC

+24V input range of voltage +24 DC:+21.6 V DC to +29 V DC

220 AC input range of 220 AC: Single-phase or three-


voltage phase power cable

110 AC input range of 220 AC: Single-phase or three-


voltage phase power cable

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 10


Typical Configurations of the BTS3900A Cabinet

1. RF cabinet 2. Power cabinet

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 11


Typical Configurations of the BTS3900A Cabinet

1. RF cabinet 2. Power cabinet

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 12


Typical Configurations of the BTS3900A Cabinet

 The BTS3900A cabinet comprises an RF


cabinet and a power cabinet. The
extension battery cabinet and
transmission cabinet are optional.

1. RF cabinet
2. Power cabinet
3. Transmission cabinet
4. Battery cabinet

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 13


BTS3900A Capacity and Characteristics

 System capacity specifications:


 BTS3900A can support up to: uplink and downlink 1536 CEs
 BTS3900A can support up to: 6*4 cells or 3*8 cells

 Characteristics
 Transmission Type: E1/T1, FE (electrical port ), FE (optical port ),
 Networking mode: star, chain and tree
 Synchronization clock sources: Iub interface clock, GPS, and internal clock
 Handover types: softer handover, soft handover and hard handover
 Services: CS services, PS services , mixed services and position services
 Enhanced functions:HSPA, MBMS, RAN sharing and RET as well

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 14


BTS3900A Logical Structure

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 15


Chapter 3 BTS3900A Hardware Structure

Section 1 BTS3900A Introduction

Section 2 Power Modules Structure

Section 3 Modules Structure

Section 4 Cables

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 16


RF Cabinet Modules

 The BTS3900A cabinet comprises an RF cabinet and a power cabinet. The


extension battery cabinet and transmission cabinet are optional.
 The RF cabinet comprises the following entities: WRFU, DCDU , FMUA,
and FAN unit. The power cabinet comprises the following entities: BBU,
PDU, PMU and PSU.
 You can choose to configure the BTS3900A with a battery cabinet and a
transmission cabinet. This helps to expand the battery capacity and the
installation space for optional user devices.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 17


RF Cabinet Modules --- WRFU Board
 The WRFU consists of the high-speed interface unit, signal processing unit,
power amplifier, and duplex unit.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 18


RF Module --- WRFU Board
Type Label Connector Type Description
Port for ANT-RXD N series female Connecting the antenna
transceiving RF connector subsystem
signals
ANT- N series female
TX/RXM connector
CPRI CPRI_W SFP female Connecting the BBU, or
connector the upper-level WRFU
during the cascading
CPRI_E SFP female Connecting the lower-
connector level WRFU during the
cascading
Interconnection port LNA1-IN QMA female Input port of diversity
for RF receive connector signals in the antenna
signals channel
LNA0-OUT QMA female Output port of diversity
connector signals in the antenna
channel
Power port POWER 3V3 power Introducing power
connector
Commissioning port COM RJ45 connector Used for commissioning

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 19


RF Module --- WRFU Board
Identifier Status Meaning
RUN On The power input is normal, but the module is faulty.

Off There is no power input, or the module is faulty.

On for 1 second and off for 1 second The module is functional.

On for 0.125 second and off for 0.125 The module is loading software or is not started.
second
ALM On The module is in the alarm status.

Off No alarm is generated.

TX_ACT On The module is functional and is connected to the BBU.

Off The module is not connected to the BBU.

On for 1 second and off for 1 second The module is in the local test status.

VSWR Off (red) No VSWR alarm is generated.

On (red) A VSWR alarm is generated.

CPRI_W On (green) The CPRI link is normal.


CPRI_E
On (red) The interface module fails to receive signals.

Red LED on for 1 second and off for The CPRI link is out of lock.
1 second

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 20


RF Module --- WRFU Board
 RF specifications:

 One WRFU supports four carriers.

 Each carrier’s maximum output power of WRFU is 80W;

 The receive sensitivity of single antenna is better than -125.8dBm;

 The receive sensitivity of two antennas is better than -128.6dBm;

 The maximum searching ability is180km. The maximum access search radius is
configurable with the step size of 300 m;

Configuration Type (No Transmit Diversity Typical Power Maximum Power


Transmit Diversity) Power (W)/Carrier Consumption (W) Consumption (W)

3*1 80 520 630


3*2 40 610 830
3*4 20 1020 1330

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 21


RF Cabinet Modules --- DCDU-02 Board
 The direct current distribution unit
(DCDU) module leads power to each
component in the cabinet.  DCDU-02 in the 3RFU cabinet or in the left
of the 6RFU cabinet
 Functions

 The DCDU supports the 1-way -


48 V DC power input and 4-way -
48 V DC power output.
 The DCDU leads -48 V DC power
to the WRFU and FMUA in the RF
cabinet.  DCDU-02 in the 3RFU cabinet or in the right of
the 6RFU cabinet
 The DCDU-02 has the built-in
surge protector board, which
provides 10 kA surge protection
capability in differential mode and
15 kA in common mode.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 22


RF Cabinet Modules --- DCDU-02 Board
Name Label Description
Wiring terminal for NEG(–) -48 V NEG input wiring terminal
power input
RTN(+) -48 V RTN input wiring terminal
Power output port RFU0 to RFU5, FMUA, •RFU0 to RFU2 supplying power to the three
and SPARE WRFUs in the 3RFU cabinet or in the left of the
6RFU cabinet
•RFU3 to RFU5 supplying power to the three
WRFUs in the right of the 6RFU cabinet
•FMUA supplying power to the FMUA
•SPARE is reserved.
Power switch RFU0 to RFU5, FMUA, •RFU0 to RFU2 controlling the current of the
and SPARE three WRFUs in the 3RFU cabinet or in the left
of the 6RFU cabinet
•RFU3 to RFU5 controlling the current of the
three WRFUs in the 6RFU cabinet or in the right
of the 6RFU cabinet
•FMUA controlling the current of the FMUA
•SPARE controlling the current of the SPARE
power output port
Alarm output port SPD ALM DUDU dry contact alarm output port

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 23


RF Cabinet Modules --- DCDU-02 Board
 220 V and 110V AC Power Distribution

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 24


RF Cabinet Modules --- FAN Unit
 The FAN unit provides the functions of ventilation and heat dissipation for the cabinets.
A FAN unit consists of two independent fans.
 Functions

 Providing forced ventilation and heat dissipation


 Supporting the temperature detection
 The FAN unit supports:
− Adjustment based on the temperature and adjustment controlled by the main
control unit
− Fan rotation control function. The FAN unit stops the rotation of the fans when
the ambient temperature is low.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 25


RF Cabinet Modules --- FMUA Board
 The FMUA module is a fan environment monitoring unit.

 Functions

 Leading -48 V DC power to the FAN unit


 Collecting environment alarms of the cabinet, such as temperature, humidity, smoke,
water, and door status alarms
 Collecting surge protection alarms of the DCDU
 Supporting the functions of temperature detection and report
 Supporting cascaded and extension FMUA through the RS485 port

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 26


RF Cabinet Modules --- FMUA Board
 the LEDs on the FMUA.

Identifier Color Status Meaning


RUN Green On for 1 second and off for 1 The module runs normally and
second communicates normally with the BBU.
On for 0.125 second and off The power supply is normal but the
for 0.125 second communications with the BBU is not
normal.
OFF There is no power supply.
ALARM Red On for 0.125 second and off Alarms are generates on both the left
for 0.125 second and right fans of the cabinet.
On for 1 second and off for 1 The fan in the right of the cabinet
second generates alarms.
ON The fan in the left side of the cabinet
generates alarms.
On for 2 second and off for 2 Other alarms are generated.
second
OFF No alarm is generated or there is no
power supply.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 27


RF Cabinet Modules --- FMUA Board
 the ports on the FMUA module
Port Type Port Connector Type Description
Power port –48 V 3V3 power connector -48 V DC power is supplied to the power
port.
RS485 COM IN RJ45 connector Connects to the main control unit.
communication COM OUT RJ45 connector Cascades lower-level FMUA.
interface
TEM RJ45 connector Indicates the port for monitoring cabinet
temperature.
TEM_HUM ARRESTER RJ45 connector Connects the SPD ALM port of the DCDU
through the monitoring signal cable
between the FUMA and DCDU.
Ports on the FAN FAN0 and FAN -1 4-pin connector Connects to the FAN unit in the left of the
unit cabinet through the power cable for the
FAN unit.
FAN2 and FAN -3 4-pin connector Connects to the FAN unit in the right of
the cabinet through the power cable for
the FAN unit.
Boolean alarm port Group one (from left to right) Dry contact connector Extension Boolean alarm port
Group two (from left to right) Dry contact connector
Group three (from left to right) Dry contact connector Ports for the smoke sensor and door
status sensor
Group four (from left to right) Dry contact connector Port for the water sensor

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 28


RF Cabinet Modules --- Batteries
 Batteries in the RF Cabinet

 The batteries in the RF cabinet provide NodeBs with power supplies.


 Batteries are configured in the 3 RFU RF cabinet.
 Appearance

 Batteries in the RF cabinet are classified into two types.

(1) -12 V 50 Ah battery (2) -12 V 92 Ah battery

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 29


Chapter 3 BTS3900A Hardware Structure

Section 1 BTS3900A Introduction

Section 2 Power Modules Structure

Section 3 Modules Structure

Section 4 Cables

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 30


Power Cabinet Modules

 The components in the power cabinet are as follows: BBU,


SLPU, PDU, PMU/PSU, AFMU, AFMI, and sensors.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 31


Logical Structure of the BBU3900 Module

OMC External Subsystem

Control Subsystem

Signaling Operation& Power mode


Clock mode Processing Maintenance

Decoding Demodulation

FP Processing
E1/T1 Transmission
FE Adaptation Power Interface
CPRI
Transport Protocol Control TO WRFU
RNC Interface Processing information Module

Codling Modulation

Transport Subsystem Baseband Subsystem

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 32


BBU3900 Module Introduction

 Full configuration

 Typical configuration

 Mandatory boards and modules:WMPT, WBBPa, UBFA, and UPEU


 The optional boards are the UELP, UFLP, UTRP, and UEIU.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 33


BBU3900 Module Introduction
F SLOT0 SLOT4 PWR0
A SLOT1 SLOT5
SLOT2 SLOT6 PWR1
N
SLOT3 SLOT7
Slot number definition

Active and standby definition


for UTRP and WMPT boards
F WBBP UTRP PWR
A WBBP UTRP
N WBBP WMPT PWR
WBBP WMPT

Slot boards definition

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 34


BBU Module --- WMPT Board
IP transmission on Loading Testing GPS antenna: SMA
Electrical Port: RJ45

LEDs
Commissioning: RJ45 IP transmission
Optical signals: SFP 4E1: DB26

 Board number:
 maximum is 2 for one BBU3900,mandatory board, working in active and standby mode
 Main Functions:

 Providing OM functions
 Controlling other boards in the system and providing the reference clock
 Providing USB ports for automatic NodeB upgraded
 Providing transmission port for Iub interface
 Providing OM channels
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 35
BBU Module --- WMPT Board
 LEDs of running status of WMPT:

Label Color Status Description


RUN Green ON The board has power input, yet the board is faulty.

OFF The board has no power input.

1s ON, 1s OFF The board is running as configured.

0.125s ON, 0.125s OFF The software is being loaded to the board, or the
board is not in use.
ALM Red ON The board is reporting alarms and is faulty.

OFF The board is operational.

ACT Green ON The board is in active mode.

OFF The board is in standby mode.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 36


BBU Module --- WMPT Board

LED Color Status Description


LEDs beside the Green ON The connections are functional.
FE1 and FE0 optical
port OFF The connections are faulty.
Yellow Blinking There is ongoing data transmission.
OFF There is no data transmission.
LEDs beside the Green ON The connections are functional.
ETH port
OFF The connections are faulty.
Yellow Blinking There is ongoing data transmission.
OFF There is no data transmission.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 37


BBU Module --- WMPT Board
 DIP Switch : The WMPT has two DIP switches: SW1 for setting the E1/T1 working

mode and SW2 for setting the protection ground for the E1.

Settings of SW1
Bit T1 Mode 120-ohm E1 75-ohm E1
Balanced Unbalanced
Mode Mode
1 ON OFF ON
2 ON OFF ON
3 OFF ON ON
4 OFF ON ON

Settings of SW2
Bit 75-ohm E1 Description
Unbalanced
Mode
1 ON The RRING is for connected
to the protection ground.
2 ON
3 ON
4 ON

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 38


BBU Module --- WBBPa Board
CPRI 0 ~2 (1.25G-2.5G): SFP LEDs

 Board number: mandatory, maximum is 6

 Main Functions:

 Providing the CPRI interface for communication between the BBU and the
WRRU or WRFU
 Processing uplink and downlink baseband signals and support HSUPA and
HSDPA function
 Supporting 1+1 backup of the CPRI interface
 According to the board processing capability, WBBP module will include seven
specifications. Current WBBP is the A version, called WBBPa.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 39


BBU Module --- WBBPa Board
 LED of running status of board :

Label Color Status Description

RUN Green ON The board has power input, yet the board is faulty.

OFF The board has no power input or is faulty.

1s ON, 1s OFF The board is operational.

0.125s ON Software is being loaded to the board.


0.125s OFF

ACT Green ON The board is operational.

OFF The board is not in use.

ALM Red OFF The board is operational.

ON The board is reporting alarms and is faulty.


CPRI0 Red OFF The optical module is not in position, or the CPRI electrical cable is not
-2 securely connected.
ON The optical module or the electrical port is in position, yet the received
signals are lost.
Blinking The associated CPRI link is out of lock.
Green ON The associated CPRI link is operational.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 40


UFAN Board

 Board number: mandatory, maximum is 1

 Main Functions:

 Controlling the fan speed


 Reporting the fan status to the WMPT
 Detecting the temperature of the fan board

Label Color Status Description

STATE Green 0.125s ON, The module is not registered, and no


0.125s OFF alarm is reported.

1s ON, 1s OFF The module is operational.

Red ON The module is reporting alarms.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 41


BBU Module --- UPEU Board

 Panel of the UPEB


 Panel of the UPEA

-48V to +12V +24V to +12V

 Board number: mandatory, maximum is 2, 1+1 backup

 Main Functions:

 Converting -48 V or +24 V DC power input to +12 V DC power that is supported


by boards
 Reporting alarms related to input and output under voltage
 Providing transmission ports for RS485 signals and dry contact alarm signals

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 42


BBU Module --- UPEU Board

 LED: The UPEU has one LED, indicating the running status of the board.

Label Color Status Description


RUN Green ON The board is operational.
OFF The board has no power input, or
the board is faulty.

 Socket and Port: The UPEU has one socket and four ports.

Label Quantity Connector Type Function


PWR 1 3V3 DC power input
EXT-ALM1 1 RJ45 Transmitting dry contact alarm signals
EXT-ALM0 1 RJ45
MON1 1 RJ45 Transmitting RS485 environment
monitoring signals
MON0 1 RJ45

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 43


BBU Module --- UTRP Board
 The UTRP provides ports for eight E1s/T1s and implements transport such as IP and
ATM between the BBU3900 and the RNC.
4 E1:DB26

Label Color Status Description


RUN Green ON The board has power input, yet the board is faulty.
OFF The board has no power input or is faulty.
1s ON, 1s OFF The board is operational.
0.125s ON, 0.125s OFF Software is being loaded to the board.
2s ON, 2s OFF The board is under test.
ACT Green ON The board is in active mode.
OFF The board is in standby mode.
ALM Red OFF The board is operational.
ON The board is reporting alarms and is faulty.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 44


BBU Module --- UEIU Board

 Board number: maximum is 2


 The UEIU Functions:

 Connecting to an external monitoring device and transmitting RS485


signals to the WMPT
 Connecting to an external alarm device and transmitting dry contact alarm
signals to the WMPT

 Port : The UEIU has four ports.

Label Connector Type


MON0 RJ45
MON1 RJ45
EXT-ALM0 RJ45
EXT-ALM1 RJ45

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 45


BBU Module --- SLPU Board
UFLP
 The auxiliary devices of the

BBU3900. The devices are UELP


the SLPU, UELP, and UFLP

 SLPU: The signal lightning

protection unit is an optional


module of the BTS3900
cabinet (-48 V) or the power
distribution cabinet.

 The UFLP and the UELP

are optional units that are


installed in the SLPU.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 46


BBU Module --- UELP Board
 UELP: The universal E1/T1 lightning protection (UELP) unit is a universal E1/T1
The UELP can be optionally installed in the SLPU or the BBU. Each UELP
supports the surge protection of 4-way E1/T1 signals.
DB25 DB26

 E1 Connection:

E1
E1

Indoor DDF

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 47


BBU Module --- UELP Board

 DIP Switch: The UELP has one DIP switch, which is used to select whether the

receive terminal is grounded. The DIP switch has four bits.

DIP DIP Status Description


Switch
1 2 3 4
S1 ON ON ON ON Used for the 75 Ω
unbalanced mode
OFF OFF OFF OFF Used for other
modes except the 75
Ω unbalanced mode

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 48


BBU Module --- UFLP Board
 UFLP: The universal FE lightning protection (UFLP) board is optionally installed in the

SLPU or BBU. Each UFLP supports 2-way FE surge protection.

 IP Cable Connection.
Transmission Equipment
LAN switch or Router

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 49


Power Cabinet Modules --- APMI
 The APMI board refers to APM Power Monitor unit Interface board.

 Function

 Transfers the APM30 serial port communication signals, Boolean input/output signals,
and EMI signals.
 Protects the dry contact input/output signals and RS485 signals (connected to the
BBU/BTS)

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 50


Power Cabinet Modules --- APMI

Port Connector Type Quantity Function


RS422 RJ45 connector 1 Connecting the monitoring signal cable
between the PMU and the APMI
TX+, TX-, 2-pin molex connector 2 Connecting the monitoring signal cable
RX+, RX- between the APMI and the BBU
IN1-IN3 2-pin molex connector 3 Connecting the dry contact alarm input cable
OUT1 2-pin molex connector 1 Connecting the optical coupling alarm output
cable

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 51


Power Cabinet Modules --- AFMU

 The AFMU board refers to APM Fan Monitor unit Interface Board.
 Function
 Provides DC power supply to
the APMI and AFMU boards through
the DC power port
 Supplies DC power to the two
fans at the top of the cabinet and reports the alarms of the fans
 Reports the alarms of the internal ambient temperature sensor, air inlet
temperature sensor, and air outlet temperature sensor
 The alarm signals of the AFMU board is transported to the APMI board through
the signal transfer cable and then is reported to the BBU

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 52


Power Cabinet Modules --- AFMU

SN Port Function
1 ALM Connecting the monitoring signal cable
between the AFMU and the APMI
2 DC INPUT Connecting the DC power cable of the
AFMU

LED Silkscreen Color Status Description

Operation RUN Green ON steady About 1 minute after the AC or DC power-on


LED
Blinking for 1s ON and 1s The system is working properly.
OFF
Blinking for 0.125s ON and The serial port communication is disrupted. The
0.125s OFF other communication is normal.
OFF steady The system is not powered on.
Alarm ALM Red ON steady An alarm is generated.
LED
OFF steady No alarm is generated, or the system is not
powered on.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 53


Power Cabinet Modules --- PDU
 The PDU (short for Power Distribution Unit) performs AC or DC power distribution.

SN Description
1 AC wiring terminals
•For the 110 V dual-live-wire input, use L2
•For the single-phase 220 V/three-phase 220 V input, use N1 and N2
2 AC wiring terminals
•For the 110 V dual-live-wire input, use L1
•For the single-phase 220 V/three-phase 220 V input, use L1, L2 and L3
3 AC output wiring terminals (Lout1, Lout2)
4 AC output wiring terminals (Nout1, Nout2)
5 AC input MCB
6 AC output MCB (controls the power supply to the heating film or heaters)
7 DC output MCBs (SW0-SW9)
8 DC output wiring terminals (LOAD0-LOAD9)

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 54


220V AC Power Subrack --- PSU(AC/DC) Board
 Function
 The power subrack consists of the PMU, PSU (AC/DC) and the wiring unit of the
power subrack (220 V). The power subrack (AC/DC) converts the 220 V AC
power to the -48 V DC power.

(1) Power running LED


(2) Protection LED
(3) Fault LED
220V AC Single Cabinet

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 55


220V AC Power Subrack --- PSU(AC/DC) Board

LED Color Status Meaning


Power Green On Normal
running
LED Off There are faults (such as no AC input, or overvoltage and
undervoltage of AC input) on the mains, or the PSU has no output.

Protection Yellow Off Normal


LED
On Temperature pre-alarm or fan pre-alarm

Fault LED Red Off Normal, or the PSU has no output because of faults (such as no AC
input, or overvoltage and undervoltage of AC input) on the mains.

On There is no output because of output overvoltage shutdown, fan


fault, overtemperature shutdown, remote shutdown, or internal
problems of the PSU.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 56


220V AC Power Subrack --- PMU Board

 The power and environment monitoring unit (PMU) is the unit for monitoring the
power and the environment. The PMU provides perfect power system management,
power distribution detection, and alarm report functions.

(1) LEDs (2) Power supply


test ports
(3) RS232/RS422 port (4) Battery control (1) Backplane port (2) DIP switch
switches
(5) COM port

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 57


220V AC Power Subrack --- PMU Board
Identifier Color Status Meaning

RUN Green On for 1 second and The module is functional, and the communication with the
off for 1 second main control unit is normal.

On for 0.125 second The module runs normally but the communication with the
and off for 0.125 main control unit fails.
second If the PMU does not communicate with the main control unit
for one minute, the communication fails. In this situation, the
RUN LED blinks four times every second.

On/Off The PMU is faulty (not in the power-on self-check state).

ALM Red On The following alarms are reported:


•Mains overvoltage or undervoltage alarm
•Busbar overvoltage or undervoltage alarm
•Power module alarm
•Load shutdown alarm

Off No alarm is generated.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 58


220V AC Power Subrack --- PMU Board
Port Purpose

RS232/RS422 port Communicating with the main control unit

Battery control The battery control switch has two control ports ON and OFF, which are
switch used for powering on and off the battery.
•Press and hold the port ON for 5s to 10s until the battery is powered on.
•Press and hold the port OFF for 5s to 10s until the battery is powered off.
CAUTION:
•You need to insert a small round bar into the hole when you operate the
battery control switch. When you hear a crack, the battery is powered on or
off.
•To operate the battery control switch on the front panel of the PMU, insert
a small round pole into the hole.

Power supply test Two power supply test holes -48 V and 0 V are available for measuring
port power voltages through an ordinary multimeter.

COM port Connecting the external signal transfer board

Backplane port Connecting the backplane

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 59


220V AC Power Subrack --- PMU Board
Bit 3 Bit 2 Bit 1 Bit 0 Monitoring Address
 DIP Switch: The DIP switch is 0 0 0 0 0000
located on the rear panel of the 0 0 0 1 0001
PMU. The DIP switch has eight
0 0 1 0 0010
bits, which are set to OFF before
0 0 1 1 0011
delivery.
0 1 0 0 0100
0 1 0 1 0101
0 1 1 0 0110
0 1 1 1 0111
1 0 0 0 1000
1 0 0 1 1001
1 0 1 0 1010
1 0 1 1 1011
1 1 0 0 1100
1 1 0 1 1101
1 1 1 0 1110
1 1 1 1 1111

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 60


Chapter 3 BTS3900A Hardware Structure

Section 1 BTS3900A Introduction

Section 2 Power Modules Structure

Section 3 Modules Structure

Section 4 Cables

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 61


BBU3900 Cable Connection

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 62


Cables --- PGND Cable
 PGND Cable

OT terminal

Name Color Cross-Sectional Area One End Is Connected to ... The Other End Is
Connected to ...
PGND cable of the Green and The cross-sectional area of a PGND terminal on the right External grounding
BTS3900 WCDMA yellow wire is 25 mm2. side of the cabinet bar of the cabinet
cabinet
PGND cable of the Green and The cross-sectional area of a PGND terminal on the right PGND terminal on
DCDU yellow wire is 6 mm2. side of the DCDU panel the right side of the
cabinet
Front door PGND Green and The cross-sectional area of a PGND terminal at the front PGND terminal in the
cable yellow wire is 6 mm2. door of the cabinet cabinet

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 63


Cables --- Power Cable

 Power Cable Between the DCDU and the BBU

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 64


Cables --- Transmission Cable

E1 Cable FE Cable

E1 Surge Protection Transfer Cable FE Surge Protection Transfer Cable

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 65


Cables --- CPRI Cable

 This describes the CPRI electrical cable. It helps to implement high speed
communication between the BBU3900 and the WRFU.
 Appearance : The CPRI electrical cable is an SFP high speed transmission
cable that has a SFP200 male connector at each end

One End The Other End


CPRI port on the WBBP CPR1_W port on the WRFU

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 66


Chapter 1 Fourth Generation NodeB Overview

Chapter 2 BTS3900A Hardware Structure

Chapter 3 BTS3900A Typical Configuration

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 67


BTS3900A Typical Configuration
 The BTS3900A supports omni-directional, 2-sector, 3-sector, and 6-sector
configurations. It also supports smooth capacity expansion from 1 x 1 to 3 x 8.
 This takes the WBBPa module that supports 3-sector and WRFU module that
supports 80 W/4 carrier as an example to describe the configurations of the
BTS3900A

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 68


Thank You
www.huawei.com

Vous aimerez peut-être aussi