Insulation Thickness= 0.

500 m =Required Inputs Valid of Turbulent Flo


Average Heat Capacity of Fluid= 2.570 KJ/kg K
Fluid Viscosity= 5.200 cP The Chemical Engineers' Resource Page
Thermal cond of Fluid= 0.600 W/m K
Thermal cond of Pipe= 30.000 W/m K Pipe
R1= 0.020 m
R2= 0.026 m
R3= 0.526 m
Mass Flow= 350000.000 kg/h
Ax pipe= 0.001 m^2 R1
Transfer Coefficient Outside Pipe= 50.000 W/m^2 K R2
Heat Transfer Coefficient in Pipe= 40394.425 W/m^2 K
Overall Heat Transfer Coefficient= 0.044 W/m^2 K
R3
Thermal cond of insulation= 0.070 W/m K
Length of pipe= 150.000 m
Inlet Temperature of Pipe (T1)= 400.000 0C
Ambient Temperature= 23.800 0C Unit 1 T1 T2 Unit 2

Outlet Temperature (T2)= 399.966867 0C


Valid of Turbulent Flow
0.999912
R3= 0.52635
U= 0.159702
m= 350000
Cp= 2.57
L= 150
Insulation

Unit 2