Vous êtes sur la page 1sur 2

Page 1

Flow Meter Site Investigation


Project: Location: Date/Time: Crew:
Omaha FM 3-2-10 DMH – LWW - JRW
MH#: Pipe Shape: Pipe Material: Pipe Size (in):
0421003 Circular Truss 24
Site ID: Address: Site Quality: Basin:
30 2665 Papillion Pkwy Good

Location Map Planar Description

Summary Description:

Site Hazards Measurements Site Conditions


Heavy Traffic? No Manhole Depth (ft): 10.5 Surcharge Evidence? Yes
Needed Traffic Attendants: No Manhole Dia. (in): 54 Depth of Surcharge (ft): 7
H2S: 0 O2: 20.8 MH Cover Size (in): 24 Depth of Debris (in): 6
LEL: 0 CO: 0 MH Cover Type: Pick hole Usable MH Steps? Top only
Describe potential hazards: Measured Flow Depth (in): 10 Meter: 2150
Velocity (fps): 2 Cellular Signal Strength: Good
Mounting Band Description: Antennae Install Considerations:

Scissor, anchors, drill, shovel for Sprinkler box


debris, meter, probes

Other Comments: Permanent Power Available?

Pipe is in poor condition. Buried electric on east and west side


City is going to jet the line. of street.
Page 2

Installation Sketch & Notes Pipe Cross Section

Depth (in) Width (in) Depth (in) Width (in)

SURFACE DOWN

INFLOW OUTFLOW

Vous aimerez peut-être aussi