Vous êtes sur la page 1sur 4

Confidential Document intended to the recipient, sharing of the

document with others violate our policies. P1soft Technologies have


all rights to take necessary actions on those who made so.

CICS-DB2 RCT entries in CICS environment

1) write a cobol+cics+db2 program.


2) Do compilation using CCICSDB2 compiler
3) Do bind with CCDB2BND

NOTE: CICS Global plan is FSSCCSPL. Please Don’t use user palns in the CICS
regions.

Example how to do entries in cics region:

PROG NAME : PGM1


MAPSET NAME : MAPSET1
TRANSID : TRN1
DB2ENTRY : ENT1
DB2TRAN : DDDD
PLAN : FSSCCSPL ===> Default
GROUP : FSSXXX ===> Should be you user id. Other Groups will be
Deleted weekly basis.

1) MAPSET DEFINE & INSTALLATION:

DEFINE:

CEDA DEF MAPSET(MAPSET1) GROUP(FSSXXX) ===>ENTER


MSG: DEFINE SUCESSFUL

INSTALLATION:

CEDA INS MAPSET(MAPSET1) GROUP(FSSXXX) ===>ENTER


MSG: INSTALL SUCESSFUL

2) PROGRAM DEFINF & INSTALLATION:

DEFINE:

CEDA DEF PROG(PGM1) GROUP(FSSXXX) ===>ENTER


MSG: DEFINE SUCESSFUL

INSTALLATION:

CEDA INS PROG(PGM1) GROUP(FSSXXX) ===>ENTER


Confidential Document intended to the recipient, sharing of the
document with others violate our policies. P1soft Technologies have
all rights to take necessary actions on those who made so.

MSG: INSTALL SUCESSFUL

3) TRANACTION DEFINE & INSTALLATION:

DEFINE:

CEDA DEF TRANS(TRN1) PROG(PGM1) GROUP(FSSXXX) ===>ENTER


MSG: DEFINE SUCESSFUL

INSTALLATION:

CEDA INS TRANS(TRN1) GROUP(FSSXXX) ===>ENTER


MSG: INSTALL SUCESSFUL

4) DB2ENTRY DEFINE & INSTALLATION:

DEFINE:

CEDA DEF DB2E(ENT1) GROUP(FSSXXX) ===> HIT ENTER WILL GET BELOW
SCREEN

OVERTYPE TO MODIFY
CEDA DEFine DB2Entry( ENT1 )
DB2Entry : ENT1
Group : FSSXXX
DEscription ==>
THREAD SELECTION ATTRIBUTES
TRansid ==> TRN1
THREAD OPERATION ATTRIBUTES
PLAN ==> FSSCCSPL === Don’t change, always use FSSCCSPL only.
MSG: DEFINE SUCESSFUL

INSTALLATION:

CEDA INS DB2E(ENT1) GROUP(FSSXXX)


Confidential Document intended to the recipient, sharing of the
document with others violate our policies. P1soft Technologies have
all rights to take necessary actions on those who made so.

OVERTYPE TO MODIFY
CEDA Install
DB2Entry ==> ENT1
Group ==> FSSXXX
MSG: INSTALL SUCESSFUL

5) DB2TRAN DEFINE & INSTALLATION:

DEFINE:

CEDA DEF DB2T(DDDD) GROUP(FSSXXX) ===> HIT ENTER WILL GET BELOW
SCREEN

OVERTYPE TO MODIFY
CEDA DEFine DB2Tran( DDDD )
DB2Tran : DDDD
Group : FSSXXX
Description ==>
Entry ==> ENT1
Transid ==> TRN1
MSG: DEFINE SUCESSFUL

INSTALLATION:

CEDA INS DB2T(DDDD) GROUP(FSSXXX) ===> HIT ENTER WILL GET BELOW
SCREEN

MSG: INSTALL SUCESSFUL

AFTER ALL ENTRIES IS DONE IN CICS REGION CLEAR THE


SCREEN(SHIFT+PAUSE BREAK) AND TYPE TRANACION ID ON CICS
TERMINAL AND HIT ENTER.
Confidential Document intended to the recipient, sharing of the
document with others violate our policies. P1soft Technologies have
all rights to take necessary actions on those who made so.

Vous aimerez peut-être aussi