Project Title :
Drawing Title :
TYPICAL SINGLE LINE DIAGRAM FOR EXISTING OG-BOX (POB / LINKWAY / TAXI STAND / BUS SHELTER) NURLY MALVIN HO MELVYN THONG
L/ROAD/MES/SD/1001 -
Rev. Date By Description Chk’d App’d
CAD File Name : LROADMES-SD1001-.dgn Sheet 1 of 1 A4
$DATE$ $TIME$ $FILE$
NOTES:
LTA Endorsement :
Project Title :
Drawing Title :
L/ROAD/MES/SD/1002 -
Rev. Date By Description Chk’d App’d
CAD File Name : LROADMES-SD1002-.dgn Sheet 1 of 1 A4
$DATE$ $TIME$ $FILE$
NOTES:
LTA Endorsement :
Project Title :
Drawing Title :
TYPICAL SINGLE LINE DIAGRAM FOR NEW OG-BOX (BUS SHELTER) NURLY MALVIN HO MELVYN THONG
SCALE: NTS Scale Drawn Date
L/ROAD/MES/SD/1003 -
Rev. Date By Description Chk’d App’d
CAD File Name : LROADMES-SD1003-.dgn Sheet 1 of 1 A4
$DATE$ $TIME$ $FILE$
NOTES:
LTA Endorsement :
Project Title :
Drawing Title :
L/ROAD/MES/SD/1004 -
Rev. Date By Description Chk’d App’d
CAD File Name : LROADMES-SD1004-.dgn Sheet 1 of 1 A4
$DATE$ $TIME$ $FILE$
LAND TRANSPORT
AUTHORITY
LOGO
UV RESISTANT
WINDOW C/W
LAND TRANSPORT
CONTRRACT NO:
SERIAL NO:
YEAR MANUFACTURE:
AUTHORITY
LOGO
NAME PLATE
SPANNERS INTERNATIONAL PTE LTD
6 CHANGI NORTH STREET 1 ISO
SPANNERS BUILDING 9002Company
Certified
SINGAPORE 498825
NEOPRENE SEAL
WEATHERPROOF
TO IP 54
REMOVEABLE
PLATE
Qualified Person Endorsement :
PLINTH C/W
OPENING FOR
CABLE ENTRY
2 NOS 50mm LTA Endorsement :
EXTERNAL VIEW
Drawing Title :
L/ROAD/MES/SD/1005 -
Rev. Date By Description Chk’d App’d
CAD File Name : LROADMES-SD1005-.dgn Sheet 1 of 1 A4
$DATE$ $TIME$ $FILE$
Back
100mm HEAVY DUTY UPVC PIPE 2 NOS 100mm HEAVY DUTY UPVC
FOR POB/LINKWAY ELECTRICAL DISTRIBUTION LEAD IN C/W 90^ LONG BEND PIPES
FOR POWER GRID INCOMING CABLING
PARTITION
GLASS
PARTITION
PLAN VIEW
Overall Length = min 1120mm Depth = min 450mm Depth = min 450mm
Overall Length = min 1120mm
420
POWER POWER
GRID GRID
1 KWH 1 KWH
METER METER
Qualified Person Endorsement :
FIX PLATE
LTA Endorsement :
BUS SHELTER BI Supply
and Installed
By PG
EXTERNAL
FRONT
DOOR
PARTITION
Project Title :
Y
STANDARD INSTALLATION DETAILS
2 NOS 100mm HEAVY DUTY UPVC 50mm HEAVY DUTY
LEAD IN C/W 90^ LONG BEND PIPES UPVC PIPE FOR BUS
FOR POWER GRID INCOMING CABLING SHELTER ADVERTISING
PLINTH C/W OPENING
PANEL
FOR CABLE ENTRY
100mm HEAVY DUTY
UPVC PIPE FOR BUS
100mm HEAVY DUTY UPVC PIPE Drawing Title :
SHELTER ELECTRICAL
FOR POB/LINKWAY ELECTRICAL DISTRIBUTION DISTRIBUTION
A
NURLY MALVIN HO MELVYN THONG
L/ROAD/MES/SD/1006 -
Rev. Date By Description Chk’d App’d
CAD File Name : LROADMES-SD1006-.dgn Sheet 1 of 1 A4
$DATE$ $TIME$ $FILE$
1 2 3
7500
PROPOSED 1 x 18W
(IP 65) LIGHT FITTING
1 2 3
7500
EARTH PIT
2 NOS. 50mm HEAVY DUTY
ROOF EAVES ABOVE (TOTAL RESISTANCE < 10ohm)
UPVC PIPE C/W PULL WIRE
A NEW
OG BOX
M.S. RHS POST @ 3000 mm C/C TO ENGR’S DTL
3
1 NO. 50mm HEAVY DUTY
1400 100 1400 UPVC PIPE C/W PULL WIRES
FROM 0G-BOX TO ADVERTISING PANEL
1 NO. ELECT. PIPE FOR ADVERTISEMENT
PANEL (AP) TO BE LOCATED AT THE
DOWNSTREAM EDGE OF BUS SHELTER Project Title :
SCALE: NTS
L/ROAD/MES/SD/1007 -
Rev. Date By Description Chk’d App’d
CAD File Name : LROADMES-SD1007-.dgn Sheet 1 of 1 A4
$DATE$ $TIME$ $FILE$
A
7500
NEW OG BOX (IP55) M.S. RHS POST @ 3000 mm C/C TO ENGR’S DETAIL
LOCATION SHALL BE SUBJECTED TO
SITE CONDITIONS AND POWERGRID’S APPROVAL
ELECTRICAL CABLE IN PVC
FLEXIBLE PIPE IN SUPPORT POST
ROAD
FOOTING TO ENGR’ S DETAIL
6m PVC EARTH BONDING CABLE IN 2 NOS 50mm HEAVY DUTY UPVC PIPES
25mm HEAVY DUTY UPVC PIPE
TYPICAL FRONT ELEVATION OF BUS SHELTER (WITHOUT RAILING) TYPICAL SECTION OF BUS SHELTER (WITHOUT RAILING)
REF. DWG. NO. L/STLBS/AR/STD/0002
7500
NEW OG BOX (IP55) M.S. RHS POST @ 3000 mm C/C TO ENGR’S DETAIL
S/S RAILING TO BE PROVIDED WHERE THERE
LOCATION SHALL BE SUBJECTED TO
IS SUDDEN GREAT DIFFERENCE IN LEVEL
SITE CONDITIONS AND POWERGRID’S APPROVAL
ELECTRICAL CABLE IN PVC
REFUSE BIN TO BE FIXED IN POSITION Project Title :
FLEXIBLE PIPE IN SUPPORT POST
ROAD
CABLE ENTRY Drawing Title :
ACCESS PANEL
FOOTING TO ENGR’ S DETAIL
(REFER TO TYPICAL
6m PVC EARTH BONDING CABLE IN
SUPPORT POST DETAIL) 2 NOS 50mm HEAVY DUTY UPVC PIPES
25mm HEAVY DUTY UPVC PIPE
TYPICAL ELECTRICAL INSTALLATION DETAILS
ELEVATION 1 2 NOS 100mm HEAVY DUTY UPVC
PIPES LEAD IN 90^ LONG BEND PIPES
FOR POWERGRID INCOMING CABLING
SECTION A-A FOR BUS SHELTER (WITH AND WITHOUT RAILING)
(REFUSE BIN NOT SHOWN FOR CLARITY) CATCH BASIN AND UPVC PIPE IN
ACCORDANCE WITH THE CURRENT
Scale 1 :20
LTA STANDARD DETAILS OF ROAD
REF. DWG. NO. L/STLBS/AR/STD/0004 ELEMENTS
TYPICAL FRONT ELEVATION OF BUS SHELTER (WITH RAILING) TYPICAL SECTION OF BUS SHELTER (WITH RAILING) Designed Checked Approved
L/ROAD/MES/SD/1008 -
Rev. Date By Description Chk’d App’d
CAD File Name : LROADMES-SD1008-.dgn Sheet 1 of 1 A4
$DATE$ $TIME$ $FILE$
A
3000
300 2700
1500
´
S/S SCREW
K
S/S SCREW
-
3%%d
200
DETAIL 2
DETAIL 2 Scale 1:5
K
-
M.S. ’C’ CHANNEL RAFTER @ 3000 mm C/C TO ENGR’S DETAIL
C LIGHT FITTING TO M&E SPECS & SHALL NOT PROTRUDE FROM M.S. RAFTER /
- CONTRACTOR TO PROPOSE FIXING BRACKET FOR LIGHT FITTING
ALUM. ROOF CAPPING FOR ROOF PANEL
TO MFR’S DETAIL
G.I. PIPE ALONG BACK OF M.S. FASCIA
FOR ELECT. CABLES TO M&E DWG. & SPEC.
MIN. 10mm THK. ALUM. HONEYCOMB ROOF PANEL
COMPLETE WITH MIN. 1mm THK. TOP PANEL
ELECTRICAL CABLE CONCEALED IN PVC TO SO’S APPROVAL
FLEXIBLE CONDUIT IN SUPPORT POST
´
M.S. RHS POST @ 3000 mm C/C TO ENGR’S DETAIL
M.S. RHS POST @ 3000 mm C/C TO ENGR’S DETAIL
DETAIL
DETAIL 1 1 SECTION B-B
Scale 1:5
M.S. ’C’ CHANNEL RAFTER TO ENGR’S DETAIL
Scale 1:5
M.S. RHS POST @ 3000 mm C/C TO ENGR’S DETAIL
SECTION C-C Y
LTA Endorsement :
SECTION C-C
-
PVC CABLE + 2.5m PVC EARTH CABLE
IN FLEXIBLE CONDUIT Scale 1:5
B 40 B
750 1500
- - ALUMINIUM OR
STEEL SUPPORT POST
EARTH PIT CABLE GLAND FOR ARMOURED CABLE
100 100
40
(TOTAL EARTH
RESISTANCE FFL
C1 WELDED ALL-ROUND TO
<10 ohms)
300x300x20 THK MS PLATE
10
Y
-
SECTION Y-Y
BUS STOP ADDRESS & NUMBER SIGN
PLATE TO FACE ONCOMING TRAFFIC IN ALUM. ROOF CAPPING FOR ROOF PANEL TO MFR’S DETAIL
ACCORDANCE TO LTA STD DRAWING NO.
LTA/ARCH/CF/97/8/13 LATEST REVISION GASKET
Project Title :
CONC. SLAB TO ENGR’S DTL COMPLETE WITH
25mm x 3mm COPPER TAPE
20mm THK GRANOLITHIC FINISHES TO SO’S APPROVAL
TYPICAL SUPPORT POST DETAIL LIGHT FITTING TO M&E SPECS & SHALL NOT PROTRUDE FROM M.S. RAFTER /
Drawing Title :
CONTRACTOR TO PROPOSE FIXING BRACKET FOR LIGHT FITTING
SECTION K-K
SECTION K-K Scale 1:5
TYPICAL CABLE ENTRY DETAIL FOR BUS SHELTER
L/ROAD/MES/SD/1009 -
Rev. Date By Description Chk’d App’d
CAD File Name : LROADMES-SD1009-.dgn Sheet 1 of 1 A4
$DATE$ $TIME$ $FILE$
2800 2800
EQ EQ EQ EQ
MIN. 10mm THK. ALUM. HONEY COMB ROOF PANEL COMPLETE MIN. 10mm THK. ALUM. HONEY COMB ROOF PANEL COMPLETE
WITH MIN. 1mm THK. TOP PANEL TO SO’S APPROVAL WITH MIN. 1mm THK. TOP PANEL TO SO’S APPROVAL
12%%d 12%%d
CHS HOT-DIPPED GALVANISED M.S. MEMBER CHS HOT-DIPPED GALVANISED M.S. MEMBER
TO ENGR’S DETAIL COMPLETE WITH SPRAY TO ENGR’S DETAIL COMPLETE WITH SPRAY
COATING FINISH TO SO’S APPROVAL COATING FINISH TO SO’S APPROVAL
PURPOSE MADE BOND PURPOSE MADE BOND
CHS HOT-DIPPED GALVANISED M.S. POST CONTRACTOR TO ENSURE THAT BONDED CHS HOT-DIPPED GALVANISED M.S. POST CONTRACTOR TO ENSURE THAT BONDED
TO ENGR’S DETAIL COMPLETE WITH SPRAY IN ACCORDANCE TO CP33 REQUIREMENTS TO ENGR’S DETAIL COMPLETE WITH SPRAY IN ACCORDANCE TO CP33 REQUIREMENTS
COATING FINISH TO SO’S APPROVAL COATING FINISH TO SO’S APPROVAL
1800 1800
FFL OF FFL OF
TYPICAL CROSS BEAM TYPICAL CROSS BEAM
POB DECK FALL FALL POB DECK FALL FALL
TO ENGR’S DETAIL TO ENGR’S DETAIL
DETAIL X
75 75
PLANTING TROUGH WITH WATERPROOFING PLANTING TROUGH WITH WATERPROOFING
MEMBRANE TO SO’S APPROVAL MEMBRANE TO SO’S APPROVAL
625 625
Y
-
25mm x 3mm
ALUMINIUM TAPE
RC COLUMN TO ENGR’S DETAIL WITH RC COLUMN TO ENGR’S DETAIL WITH Qualified Person Endorsement :
20mm THK PRECASTED GRANOLITHIC 20mm THK PRECASTED GRANOLITHIC
CHIPPING FINISHED TO S.O’S APPROVAL CHIPPING FINISHED TO S.O’S APPROVAL
M5 COUNTERSUNK BOLT NUT INSERT
LIGHTNING
PROTECTION
BI-METALLIC
TEST
CONNECTOR
BOX
25mm x 3mm
STAINLESS STEEL
COPPER TAPE
COVER PLATE
LTA Endorsement :
Y
-
1800 1800
FFL OF FFL OF
TYPICAL CROSS BEAM TYPICAL CROSS BEAM
POB DECK FALL FALL POB DECK FALL FALL
TO ENGR’S DETAIL TO ENGR’S DETAIL
DETAIL X
75 75
PLANTING TROUGH WITH WATERPROOFING PLANTING TROUGH WITH WATERPROOFING
MEMBRANE TO SO’S APPROVAL MEMBRANE TO SO’S APPROVAL
25mm x 3mm
ALUMINIUM TAPE
RC COLUMN TO ENGR’S DETAIL WITH RC COLUMN TO ENGR’S DETAIL WITH M5 COUNTERSUNK BOLT NUT INSERT
Qualified Person Endorsement :
20mm THK PRECASTED GRANOLITHIC 20mm THK PRECASTED GRANOLITHIC
CHIPPING FINISHED TO S.O’S APPROVAL CHIPPING FINISHED TO S.O’S APPROVAL
LIGHTNING
PROTECTION
BI-METALLIC
TEST
CONNECTOR
BOX
25mm x 3mm
STAINLESS STEEL
COPPER TAPE
COVER PLATE
Y
- LTA Endorsement :
ENCASED HEAVY
DUTY UPVC PIPES
25mm x 3mm
150mm x 150mm TEST LINK BOX ALUMINIUM TAPE
AT 1500mm HEIGHT FROM STAINLESS STEEL
COVER PLATE
GROUND LEVEL (SURFACE MOUNT)
IN ACCORDANCE TO CP33 REQUIREMENTS
(SEE TYPICAL LIGHTNING PROTECTION BI-METALLIC
150mm x 150mm TEST LINK BOX TEST BOX AT POB) CONNECTOR
AT 1500mm HEIGHT FROM
GROUND LEVEL (SURFACE MOUNT)
IN ACCORDANCE TO CP33 REQUIREMENTS
(SEE TYPICAL LIGHTNING PROTECTION
TEST BOX AT POB) Project Title :
25mm x 3mm R.C. COLUMN
COPPER TAPE
ENCASED HEAVY
DUTY UPVC PIPES
R.C. GRATING
EARTH PIT
(TOTAL EARTH RESISTANCE 10ohms)
ROAD LEVEL TYPICAL LIGHTNING PROTECTION Drawing Title :
FOOTPATH LEVEL TO ROADSIDE DRAIN
EARTH ROD TEST BOX AT POB
ROAD LEVEL
TYPICAL LIGHTNING PROTECTION SYSTEM
TO ROADSIDE DRAIN
EARTH ROD
FOR UNCOVERED PEDESTRIAN OVERHEAD BRIDGE
¨81
G.I. PIPE ALONG BACK OF M.S. FASCIA ALUM FLASHING PIECE BOLTED AT BOTH END
FOR ELECT. CABLES TO M&E DWG. & SPEC. LIGHT FITTING TO M&E SPEC & SHALL NOT PROTRUDE FROM M.S. RAFTER /
CONTRACTOR TO PROPOSE FIXING BRACKET FOR LIGHT FITTING
50 x 50 x 3 ALUM ANGLE PLATE
M.S. ANGLE ROOF FASCIA TO ENGR’S DETAIL
M.S. RHS POST @ 3000 mm C/C TO ENGR’S DETAIL
M.S. ’C’ CHANNEL RAFTER TO ENGR’S DETAIL
MIN. 10mm THK. ALUM. HONEYCOMB ROOF PANEL
COMPLETE WITH MIN. 1mm THK. TOP PANEL
LIGHT FITTING TO M&E SPEC & SHALL NOT PROTRUDE FROM M.S. RAFTER /
TO SO’S APPROVAL
CONTRACTOR TO PROPOSE FIXING BRACKET FOR LIGHT FITTING ELECTRICAL CABLE CONCEALED IN PVC
FLEXIBLE CONDUIT IN SUPPORT POST
M.S. RHS POST @ 3000 mm C/C TO ENGR’S DETAIL ALUM. ROOF CAPPING FOR ROOF PANEL
TO MFR’S DETAIL
750
SECTION C-C
SECTION C-C Scale 1:5
´
50 mm PVC FLEXIBLE CONDUIT
FOR INCOMING CABLES TO M&E DETAIL
SECTION B-B
Scale 1:5
SECTION B-B
SECTION J-J
TYPICAL LONGITUDINAL CROSS SECTION AT ROOF WITH LEVEL DIFFERENCE
TYPICAL LONGITUDINAL CROSS SECTION AT ROOF WITH LEVEL DIFFERENCE
Scale 1:5
REF. DWG. NO. L/STLLW/AR/STD/1002
Qualified Person Endorsement :
A
MIN. 10mm THK. ALUM. HONEYCOMB ROOF
PANEL COMPLETE WITH MIN. 1mm THK.
300 TOP PANEL TO SO’S APPROVAL
Y
-
LTA Endorsement :
DETAIL 2
Scale 1:5
750 1500
DETAIL X
DETAIL 1
DETAIL 1
Scale 1:5
ALUM. ROOF CAPPING FOR ROOF PANEL TO MFR’S DETAIL
M.S. SUPPORT POST @ 3000 mm C/C TO ENGR’S DETAIL 50 X 50 X 3 ALUM ANGLE PLATE
M.S. SUPPORT POST @ 3000 mm C/C TO ENGR’S DETAIL
SECTION C-C
SECTION C-C
TO SO’S APPROVAL
Scale 1:5
ALUM. ROOF CAPPING FOR ROOF PANEL
TO MFR’S DETAIL ELECTRICAL CABLE CONCEALED IN PVC
FLEXIBLE CONDUIT IN SUPPORT POST
GASKET
´
M.S. ANGLE ROOF FASCIA
´ MIN. 10mm THK. ALUM. HONEYCOMB ROOF PANEL
COMPLETE WITH MIN. 1mm THK. TOP PANEL
TO ENGR’S DETAIL
TO SO’S APPROVAL
Y
-
A B
2400
S/S SCREW Y
-
SECTION Y-Y
DETAIL X
M.S. ANGLE ROOF FASCIA
TO ENGR’S DETAIL
SECTION B-B
IN FLEXIBLE CONDUIT
STANDARD INSTALLATION DETAILS
TERMINAL BLOCK CONNECTOR
MOUNTED ON TEAKWOOD BLOCK
SEE DETAIL X
B B
- -
FLAT BAR TO SUPPORT TEAKWOOD BLOCK Drawing Title :
100 40 100
CABLE GLAND FOR ARMOURED CABLE
EARTH PIT
(TOTAL EARTH OPENING FOR INCOMING CABLES COVERED
RESISTANCE
<10 ohms)
FFL BY POST CAPPING
(TO BE PROVIDED AT 1ST & LAST POST ONLY)
FFL
TYPICAL CABLE ENTRY DETAIL
C1 WELDED ALL-ROUND TO
300x300x20 THK MS PLATE FOR DOUBLE POST COVERED LINKWAY
CONC. SLAB TO ENGR’S DTL COMPLETE WITH
20mm THK GRANOLITHIC FINISHES TO SO’S APPROVAL
25mm x 3mm
RC FOOTING TO ENGR’S DETAIL TYPICAL CROSS SECTION Scale Drawn Date
COPPER TAPE Scale 1:5
N.T.S. JULI JULY 2007
ARMOURED CABLE IN UPVC PIPE
L/ROAD/MES/SD/1013 -
TYPICAL CROSS SECTION FOR DOUBLE POST COVERED LINKWAY Rev. Date By Description Chk’d App’d
CAD File Name : LROADMES-SD1013-.dgn Sheet 1 of 1 A4
$DATE$ $TIME$ $FILE$
1 2 3 4 5 6 7 8 9 10
750 3000 3000 750
BONDING DETAILS TO
750 3000 3000 750
ROOF SPECIALIST’S REQUIREMENTS
750 3000 3000 3000 750 ¨81
¨81
BONDING TO UPPER ROOF
LIGHTNING PROTECTION SYSTEM
(BONDING DETAILS TO ROOF
SPECIALIST’S REQUIREMENTS) ALUM FLASHING PIECE
J
BONDING DETAILS TO L/STLLW/AR/STD/1006 MS ANGLE ROOF FASCIA
ROOF SPECIALIST’S REQUIREMENTS TO ENGR’S DETAIL
EARTH
PIT
OG BOX FFL
FFL
1 2 3 4 5 6 7
750 3000 3000 3000 3000 3000 3000 750
(CLEAR)
SUPPORT POST TO ENGR’S DETAIL
OG BOX
FFL
Qualified Person Endorsement :
EARTH
OG BOX ON CONC. PLINTH TO M&E DTLS PIT
(LOCATION TO BE DETERMINED ON SITE &
TO POWERGRID’S APPROVAL)
FRONT ELEVATION 1 (WITHOUT LEVEL DIFFERENCE)
FRONT ELEVATION OF OG BOX POSITION Scale 1:50
1 2 3 4 5 6 7
1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500
K K
L/STLLW/AR/STD/1006 -
1
MIN. 10mm THK. ALUM. HONEY COMB ROOF PANEL
COMPLETE WITH MIN. 1mm THK. TOP PANEL TO -
SO’S APPROVAL
1500 1500
OG BOX ON CONC. PLINTH TO M&E DTLS
200 820 (LOCATION TO BE DETERMINED ON SITE & ROOF EAVES ABOVE
TO POWERGRID’S APPROVAL)
(CLEAR)