Vous êtes sur la page 1sur 11

SINGLE CELL FUNCTIONAL

TEST REPORT
CIRCLE-UP EAST

SITE NAME -
Vinayaka
SITE ID - UE_VRN_VRNS_002
CARRIER - (553)

  Name Date
Name of Huawei
Created by
Analyst
Aprroved by MTS Representative
Abstract: This document contains the reports for Single Cell Functional Test
1 SCFT CHECK LIST
Site Parameter (From Planning):
Ant. Tilt Tilt Total Power
BTS ID BTS_Name Sec. PN Azimuth BW Ant_Type
Height (E) (M) Tilt (dBm)
116 UE_VRN_VRNS_002 Alpha 11 0 NA 29 AXM-806-960-65.5i-A-D 1 1 2 43
116 UE_VRN_VRNS_002 Beta 279 120 NA 29 AXM-806-960-65.5i-A-D 1 1 2 43
116 UE_VRN_VRNS_002 Gamma 447 240 NA 29 AXM-806-960-65.5i-A-D 1 1 2 43

Technical Parameter (From DT and BSC):


Search Search Search Cell Raduis SCFT
BTS ID Cell Type Sec. PN Long Lat CBSC LAC VSWR
WIN_A WIN_N WIN_R (Km) Date
116 COVERAGE Alpha 111 82.99132 25.29922 0X112 1.1 28 chips 60 chips 80 chips 15 8/4/2011
116 COVERAGE Beta 279 82.99132 25.29922 0X112 1.1 28 chips 60 chips 80 chips 15 8/4/2011
116 COVERAGE Gamma 447 82.99132 25.29922 0X112 1.2 28 chips 60 chips 80 chips 15 8/4/2011

Drive Test Information:


CALL TYPE MIN  ESN
LONG 9151004779
SHORT 9151004758
LANDLINE

Log File Details:


S.No. LOG File Name Start Time Comments
1 SCFT_UE_VRN_VRNS_043__8-4-2011
2. Call Testing:

Short Call Tests.xls

20 Short Calls from each Sector.


Call Duration should be 30 Sec for Short Call.
Origination and Termination Handset should be connected to Drive test Kit.
3. Results:
Call Stats from drive test:
Short Call (Orig) Short Call (Term) Long Call Remarks
Call Attempts (Count) 60 60 1
Access Failure (Count) 0 0 0
Call Drop (Count) 0 0 0
Access Failure (%) 0 0 0
Call Drop (%) 0 0 0
CCSR (%) 100 100 100

Call Attempts = Orig Attempt + Term Attempt


Access Failure = Orig Failure + Term Failure
CSSR: Call Setup Success Rate

Drive Test Stats:


L-M Complete* NA NA NA
M-L Complete** NA NA NA
Aggregate Ec/Io -3.0 -3.2 -2.6
Forward FER 0.093 0.0067 0.187
MTx Pwr (dBm) -36.24 -32.13 -40.32
MTx Gain Adjacent -34.81 -37.94 -40.61
MRx Pwr (dBm) -52.92 -54.72 -55.96
SHO from 1 to N/A OK OK
SHO from 2 to OK N/A OK
SHO from 3 to OK OK N/A

*L-M (Landline to Mobile)


**M-L (Mobile to Landline)
2 DRIVE TEST PLOTS
Mobile FER with Legend

Figure 1
MRx Power Plot with Legend

Figure 2
MTx Power Plot with Legend

Figure 3
Ec/Io 1st Best Plot with Legend
Figure 4

Aggregate Ec/Io Plot with Legend


Figure 5
Stronger / Domi PN Plot with Legend

Figure 6