Vous êtes sur la page 1sur 1

www.clarksol.

com
UNO
Boxer Series D Pump
DC Power, Gases to 4 LPM, Vacuum to 733 mbar, Pressure to 10 PSI
DESCRIPTION
The Boxer D is essentially two of the Boxer S pump heads powered
by a single motor. The double arrangement of ports allows to con-
nect the pump heads in parallel for maximum flow, or in series for
maximum pressure/vacuum.

SPECIFICATIONS
Permanent Magnet Motor Ratings: 4.5 or 6.5 VDC
Core Less Motor Ratings: 6, 9, 12, 18, or 24 VDC
Max Free Flow: 4.0 l/min
Max Pressure, Parallel Configuration: 6.8 PSI (0.469 bar)
Max Pressure, Serial Configuration: 10 PSI (0.689 bar)
Max Vacuum, Parallel Configuration: 400 mbar (300 mmHg)
Max Vacuum, Serial Configuration: 733 mbar(550 mmHg)
Tube Connection: Ø3.5mm (X4 positions)
Weight: 39g
Housing Material: PPO (Polyphenylene oxide)
Diaphragm & Valve Material: Silicone, other materials on
request
FLOW CURVE
DIMENSIONS (MM)

MOUNTING
A unique feature of the Boxer pumps is the ability to mount the pumps as a
push fit into your equipment. The pump has been designed to fit tightly onto
the crank-case lid. The lid in
this case acts as a fitting
accessory for the pump.
Fitting the pump via
the lid onto your equipment
allows you to remove or
replace the pump without
the need of any tools. Just ORDERING INFORMATION
push the pump onto the lid AB (DM6.5S)
and pull it out whenever
desired. A
The Boxer S pumps Model
have 6 mounting holes and
the Boxer D has 8 mounting DM-4.5=Permanent Magnet Motor, 4.5 VDC
holes for your choice. Nor- DF-6=Core-less Precious Metal, 6 VDC
mally two mounting screws are sufficient to secure the pump into your instru- DF-12=Core-less Precious Metal, 12 VDC
ment. DM-6.5=Permanent Magnet Motor, 6.5 VDC
The crank-case lid has two blind mounting holes for No. 2 self tapping
screws and two through holes for M2 machine screws. You can use the two M2 DF-9=Core-less Precious Metal, 9 VDC
machine screws in order to mount the crank-case lid either from the outside or DF-18=Core-less Precious Metal, 18 VDC
the inside of the instrument. DF-24=Core-less Precious Metal, 24 VDC
The two other mounting holes (four for the D range), are on the side
plates of the pump. These holes are 10mm deep

Clark Solutions 10 Brent Drive Hudson, MA 01749 Tel. 978 / 568 3400 Fax 978 / 568 0060

Vous aimerez peut-être aussi