CALCULATION SHEET

SACRIFICIAL ANODE CATHODIC PROTECTION SYSTEM

Project Modification Sistem Penyimpanan Dan Perbaikan Fasilitas Operasi Di Terminal Buatan -Field Lirik
Client PERTAMINA EP REGION SUMATRA
Type of System Sacrificial Anode Cathodic Protection
Anode Type Bolted Magnesium Anode
Design Life 10 years
CP Current Density 20 mA/m2
Coating Breakdown 5 %
Safety Factor 25 %
Anode Consumption Rate 1212 A-h/Kg
Utilization factor 80 %

Tank Tank Coating Estimate Bare Steel Required Anode Min. Anode Per Anode
No. Description Outside Length Surface Total Surface Type Coating Current Density Protective Weight Quantity Weight
Diameter(m) (m) Area (m2) Area (m2) Breakdown (mA/m2) Current (A) (kgs) (pcs) (kgs)
T-03A Storage Tank 20.200 12.200 1,597.23 FBE 5.0% 20.0 1.597 115.52 12 10
Bottom 320.47 Safety Factor 25%
Body 774.21 0.399
Roof 502.54 1.997
T-03B Storage Tank 20.200 12.200 1,597.23 FBE 5.0% 20.0 1.597 115.52 12 10
Bottom 320.47 Safety Factor 25%
Body 774.21 0.399
Roof 502.54 1.997
TOTAL 24 20

NOTES :
1 Current Density of 20 mA/m2 is applied for bare steel pipes buried in soil with moderate corrosivity level (assumed soil resistivity vary between 2,000~10,000 ohm.cm)
2 o o
2 The current density of bare steel shall be increased by 1 mA/m for each C above 25 C.
3 Estimate Coating Breakdown of 1% is assumed for U/G Pipes with Three Layers Polypropylene or Fussion Bonded Epoxy Coating for design life 20 years.
4 Field joint coating type shall be compatible with pipeline coating.