SPACEFLIGHT TRACKING AND DATA NETWORK

ENGINEERING CHANGE

Title: SSAR-IF Installation EC: 8412CH1

System: SSAR-IF

Req. Source: TO-13 Time Estimate: 4912 Hours

Cost Estimate: $355,000

NASA Cognizant Engineer/ Phone: Harold Brockelsby; 505-527-7007 Approval:

Contractor Cognizant Engineer: Mark Hibner; 505-525-6309 Chairperson, Date


Hobie Veitch; 505-525-6302 Configuration Control Board

Engineering Manager Date

Operations Manager Date

Security Manager Date

IT Security Date

Hardware CM Date

Attachments: Fig. 3-1a,b: SSA/KSA IF Switch Chassis Coupler


Fig. 3-2: SSA Rack I/O Panel Modification
Fig. 4-1: STGT SSAR-IF Switch Status/Cmd Cable
Fig. 4-2: WSGT SSAR-IF Switch Status/Cmd Cable
Fig. 4-3: GRGT SSAR-IF Switch Status/Cmd Cable
Fig. 5-1: SSAR-IF Service Interfaces
Fig. 5-2: 7709S Rack Elevation
Fig. 5-3: 7213W Rack Elevation
Fig. 5-4: 7213W Patch Panel Layouts
Fig. 5-5: 1421G 7211G Rack Elevation
Fig. 5-6: 1421G 7211G Patch Panel Layouts
Peer-Level Review Design Review Minutes
Workstation Displays
Test Data Record
Document Upgrade Control Sheet (DUCS)
Hardware Upgrade Control Sheet (HUCS)
Cable Upgrade Control Sheet (CUCS)

DR#: CMFS: SW 46808, SPSR 46991, CCS 46993

1.0 STATIONS AFFECTED: STGT, WSGT, GRGT

2.0 APPLICATIONS:

EC No. 8412CH1
Date: 4/2/2007 2/8/2006
Page 1 of 27
2.1 Statement of Requirements

2.1.1 The customer requires an S-Band return 370MHz Intermediate Frequency (IF) service be
added to the White Sands Complex (WSC) and to the Guam Remote Ground Terminal
(GRGT) for SGLTs 1 through 6. Each SGLT SSA A&B chain will require a 370MHz IF
signal for service redundancy. One IF customer demark is required at WSGT and one at
GRGT. This capability will provide an S-Band return IF service through the Tracking and
Data Relay Satellite System (TDRSS). The customer will be responsible for the processing
of the IF signal once delivered.

2.2 Theory of Modification

2.2.1 Hardware Modifications:


The modifications for the SSA/KSA IF Switch call for the PRE-DEMOD OUT front panel test
port to be routed to the rear panel of the chassis. Both the SSA and KSA IF Switches will be
modified. A coupler will be installed to retain the front panel test point in the new design.
Spare (SMA) RF connectors located on the rear of the SSA/KSA IF Switch chassis already
exist to route the new IF signal from the chassis. For the STGT SGLT’s, the SSA/KSA IF
Switch chassis of SGLTs 1, 2 and 3 will be routed through a an RF-compatible Low Noise
Amplifier (LNA) and Fiber Optic Transceiver System (FOTS) and over the Inter-facility Link
(IFL) to the WSGT. The signal will be routed through a fiber optic amplifier to The wideband
LNA improves improve the overall noise figure through the fiber optic system. The FOTS
receivers will be interfaced through a patchpanel to the IF Switch. For the WSGT SGLTs 4
and 5, the 370 MHz IF outputs from the SSA/KSA IF Switch chassis are interfaced to the IF
Switch through a patchpanel. The IF Switch at WSGT will require a new equipment rack. For
the SGLT-6 SSAR IF service, the 370 MHz S-band IF outputs are routed through a
patchpanel to a separate 16x16 IF switch located in (an existing) rack 1421 7211.

The IF Switches will be equipped with input attenuator/gain modules to allow for SGLT-
specific adjustments. The IF Switches will also be equipped with output signal detectors that
would be telemetered back to the DIS ADPE for fault isolation/failover capability. Patchpanels
provide redundancy to the IF Switch and also provide a means for system troubleshooting.
Control and status of the IF Switch is through spare channels in the STGT IF Switch
Controller (SISC) and via an IF Switch Controller card installed in the Guam Local Interface
Switch Controller (GLISC) at GRGT. They will use existing control and status paths to the
DIS ADPE.

2.2.2 Software Modifications:


Upon receipt of an SSAR “IF service” request, the WSC ADPE computers (DIS, EXEC,
NCCDS and USS) will ensure that there are no conflicts with existing services and will
configure the new S-Band return IF service and the S-band IF Switch. Minimal modifications
are required to the USS and EXEC software. NCCDS modifications will include adding the S-
band return IF service scheduling capability and ensure that scheduled events will be
compliant with established ground rules.

The WSC modifications to the DIS software will terminate the IF signals at the IF switch
during inter-service periods. DIS ADPE software and database changes are required to
implement the new S-band IF Switches. This proposal also implements fault detection and
failover algorithms on the return service based on existing KaTP and DIS designs using
status from the S-band IF switch output signal presence detectors.

Several workstation displays will either be modified or newly constructed to account for
control and status of the S-band IF Switch (See Workstation Displays attachment).

EC No. 8412CH1
Date: 4/2/2007 2/8/2006
Page 2 of 27
2.2.3 Firmware Modifications:
Firmware modifications will be required to add Control and Status functions of the SSA IF
Switch to the STGT IF Switch Controller (SISC) chassis and to the STGT and WSGT CTFS
SSCs. The SISC was originally constructed with expansion capabilities to control an
additional switch.

A Guam IF Switch controller function will be developed and added to the Guam Local
Interface Switch Controller (GLISC) chassis. The controller will take commands from either of
the WSGT CTFS SSCs and provide a return route for status utilizing the RS-422 protocol.
An increase in the baud rate from 9.6Kbs to 19.2Kbs will be required for the link between the
GRGT LI Switch Controller and the WSGT CTFS SSCs through the GDIS MegaMux Plus.

2.3 Equipment Affected


Rack: NENS Tag: Description: Type:
1007S G04831 SSA/KSA IF Switch S1SSA1A Modified w/ Coupler & Interfaced
1008S G04818 SSA/KSA IF Switch S1SSA1B Modified w/ Coupler & Interfaced
1009S G04588 SSA/KSA IF Switch S1SSA2A Modified w/ Coupler & Interfaced
1010S G04576 SSA/KSA IF Switch S1SSA2B Modified w/ Coupler & Interfaced
1011S G04804 SSA/KSA IF Switch S1KSA1A Modified w/ Coupler & Interfaced
1013S G04795 SSA/KSA IF Switch S1KSA1B Modified w/ Coupler & Interfaced
1014S G04612 SSA/KSA IF Switch S1KSA2A Modified w/ Coupler & Interfaced
1016S G04598 SSA/KSA IF Switch S1KSA2B Modified w/ Coupler & Interfaced
1207S G05700 SSA/KSA IF Switch S2SSA1A Modified w/ Coupler & Interfaced
1208S G05685 SSA/KSA IF Switch S2SSA1B Modified w/ Coupler & Interfaced
1209S G05465 SSA/KSA IF Switch S2SSA2A Modified w/ Coupler & Interfaced
1210S G05452 SSA/KSA IF Switch S2SSA2B Modified w/ Coupler & Interfaced
1211S G05673 SSA/KSA IF Switch S2KSA1A Modified w/ Coupler & Interfaced
1213S G05655 SSA/KSA IF Switch S2KSA1B Modified w/ Coupler & Interfaced
1214S G05485 SSA/KSA IF Switch S2KSA2A Modified w/ Coupler & Interfaced
1216S G05468 SSA/KSA IF Switch S2KSA2B Modified w/ Coupler & Interfaced
1407S G05906 SSA/KSA IF Switch S3SSA1A Modified w/ Coupler & Interfaced
1408S G05889 SSA/KSA IF Switch S3SSA1B Modified w/ Coupler & Interfaced
1409S G05730 SSA/KSA IF Switch S3SSA2A Modified w/ Coupler & Interfaced
1410S G05715 SSA/KSA IF Switch S3SSA2B Modified w/ Coupler & Interfaced
1411S G05879 SSA/KSA IF Switch S3KSA1A Modified w/ Coupler & Interfaced
1413S G05861 SSA/KSA IF Switch S3KSA1B Modified w/ Coupler & Interfaced
1414S G05756 SSA/KSA IF Switch S3KSA2A Modified w/ Coupler & Interfaced
1416S G05739 SSA/KSA IF Switch S3KSA2B Modified w/ Coupler & Interfaced
1007W G02175 SSA/KSA IF Switch S4SSA1A Modified w/ Coupler & Interfaced
1008W G02164 SSA/KSA IF Switch S4SSA1B Modified w/ Coupler & Interfaced
1009W G01971 SSA/KSA IF Switch S4SSA2A Modified w/ Coupler & Interfaced
1010W G01959 SSA/KSA IF Switch S4SSA2B Modified w/ Coupler & Interfaced
1011W G02157 SSA/KSA IF Switch S4KSA1A Modified w/ Coupler & Interfaced
1013W G02144 SSA/KSA IF Switch S4KSA1B Modified w/ Coupler & Interfaced
1014W G01993 SSA/KSA IF Switch S4KSA2A Modified w/ Coupler & Interfaced
1016W G01980 SSA/KSA IF Switch S4KSA2B Modified w/ Coupler & Interfaced
1207W G03008 SSA/KSA IF Switch S5SSA1A Modified w/ Coupler & Interfaced
1208W G02995 SSA/KSA IF Switch S5SSA1B Modified w/ Coupler & Interfaced
1209W G02787 SSA/KSA IF Switch S5SSA2A Modified w/ Coupler & Interfaced
1210W G02775 SSA/KSA IF Switch S5SSA2B Modified w/ Coupler & Interfaced
1211W G02987 SSA/KSA IF Switch S5KSA1A Modified w/ Coupler & Interfaced
1213W G02973 SSA/KSA IF Switch S5KSA1B Modified w/ Coupler & Interfaced
1214W G02809 SSA/KSA IF Switch S5KSA2A Modified w/ Coupler & Interfaced
1216W G02797 SSA/KSA IF Switch S5KSA2B Modified w/ Coupler & Interfaced
1407G G52324 SSA/KSA IF Switch S6SSA1A Modified w/ Coupler & Interfaced

EC No. 8412CH1
Date: 4/2/2007 2/8/2006
Page 3 of 27
1408G G52339 SSA/KSA IF Switch S6SSA1B Modified w/ Coupler & Interfaced
1409G G72609 SSA/KSA IF Switch S6SSA2A Modified w/ Coupler & Interfaced
1410G G72621 SSA/KSA IF Switch S6SSA2B Modified w/ Coupler & Interfaced
1411G G52347 SSA/KSA IF Switch S6KSA1A Modified w/ Coupler & Interfaced
1413G G52364 SSA/KSA IF Switch S6KSA1B Modified w/ Coupler & Interfaced
1414G G72631 SSA/KSA IF Switch S6KSA2A Modified w/ Coupler & Interfaced
1416G G52535 SSA/KSA IF Switch S6KSA2B Modified w/ Coupler & Interfaced
7213W G07880 SSAR-IF Rack Installed
7709S Amplifier, 8 Channel Installed
7709S Amplifier, 8 Channel Installed
7213W Fiber Optic Amplifier Installed
7709S FOTS, 8 Channel Installed
7709S FOTS, 8 Channel Installed
7709S Fiber Mux 16:1 Installed
7104S G04516 BCP FOTS, CH9 Modified w/CCA Install
7104W G01895 BCP FOTS, CH9 Modified w/CCA Install
7213W Fiber Demux 16:1 Installed
7213W FOTS, 8 Channel Installed
7213W FOTS, 8 Channel Installed
7213W SSAR IF Switch Controller/PS, 32x32 Installed
7213W SSAR IF Switch Matrix, 32x32 Installed
1421G 7211G SSAR IF Switch Controller/PS, 16x16 Installed
1421G 7211G SSAR IF Switch Matrix, 16x16 Installed
1057S STGT CTFS SSC-A Modified w/ Code
1059S STGT CTFS SSC-B Modified w/ Code
1057W WSGT CTFS SSC-A Modified w/ Code
1059W WSGT CTFS SSC-B Modified w/ Code
1007S G04812 Rack, SGLT-1 SSA1A Modified I/O Panel & Interfaced
1008S G04812 Rack, SGLT-1 SSA1B Modified I/O Panel & Interfaced
1009S G04571 Rack, SGLT-1 SSA2A Modified I/O Panel & Interfaced
1010S G04571 Rack, SGLT-1 SSA2B Modified I/O Panel & Interfaced
1207S G05680 Rack, SGLT-2 SSA1A Modified I/O Panel & Interfaced
1208S G05680 Rack, SGLT-2 SSA1B Modified I/O Panel & Interfaced
1209S G05446 Rack, SGLT-2 SSA2A Modified I/O Panel & Interfaced
1210S G05446 Rack, SGLT-2 SSA2B Modified I/O Panel & Interfaced
1407S G05895 Rack, SGLT-3 SSA1A Modified I/O Panel & Interfaced
1408S G05895 Rack, SGLT-3 SSA1B Modified I/O Panel & Interfaced
1409S G05710 Rack, SGLT-3 SSA2A Modified I/O Panel & Interfaced
1410S G05710 Rack, SGLT-3 SSA2B Modified I/O Panel & Interfaced
1007W G02159 Rack, SGLT-4 SSA1A Modified I/O Panel & Interfaced
1008W G02159 Rack, SGLT-4 SSA1B Modified I/O Panel & Interfaced
1009W G01954 Rack, SGLT-4 SSA2A Modified I/O Panel & Interfaced
1010W G01954 Rack, SGLT-4 SSA2B Modified I/O Panel & Interfaced
1207W G02990 Rack, SGLT-5 SSA1A Modified I/O Panel & Interfaced
1208W G02990 Rack, SGLT-5 SSA1B Modified I/O Panel & Interfaced
1209W G02770 Rack, SGLT-5 SSA2A Modified I/O Panel & Interfaced
1210W G02770 Rack, SGLT-5 SSA2B Modified I/O Panel & Interfaced
1407G G52336 Rack, SGLT-6 SSA1A Modified I/O Panel & Interfaced
1408G G52336 Rack, SGLT-6 SSA1B Modified I/O Panel & Interfaced
1409G G52544 Rack, SGLT-6 SSA2A Modified I/O Panel & Interfaced
1410G G52544 Rack, SGLT-6 SSA2B Modified I/O Panel & Interfaced
7709S IF Switch Controller Modified w/ Code & Interfaced
1457G G52287 GUAM LI Switch Controller Modified w/ Code & Interfaced
7709S G05343 Rack, Ka IF Modified w/ New Equip
1421G 7211G G52646 Rack, IF Service Modified w/ New Equip

EC No. 8412CH1
Date: 4/2/2007 2/8/2006
Page 4 of 27
3.0 EQUIPMENT MODIFICATION INSTRUCTIONS: Schedule all work prior to modifications.

3.1 SSA/KSA IF Switch Coupler Installation for SGLTs 1, 2, 3, 4, 5, & 6 SSA and KSA chains, 48 total.
See HUCS for required chassis to modify and Figure 3-1a and 3-1b for installation details.
3.1.1 Physically attach new directional coupler to vertical steel plate.
3.1.2 Remove attenuator AT2 and associated cable from Power Splitter PS3-1 (to front panel test
point).
3.1.3 Cable new directional coupler’s tap to front panel test point “Pre Demod Out” using existing
cable W119.
3.1.4 Cable PS3-1 to the new directional coupler’s input, and the output to the unused rear
connector J11 J17.
3.1.5 Verify all SMA connectors are torqued to 7-10 inch pounds (80-110 N.cm).

3.2 SSA Rack I/O Panel Modifications.


3.2.1 Modify SGLTs 1, 2, 3, 4, 5, 6 SSA I/O panels (A1) to accommodate a new bulkhead
connector (J24) for the SSAR-IF Service, See Figure 3-2 for modification details.

4.0 SYSTEM INTEGRATION INSTRUCTIONS:

4.1 Construct cables utilizing the following: Figures 4-1, 4-2, 4-3, attached drawings, and the Cable
Upgrade Control Sheet (CUCS).
4.2 Increase the communications baud rate from 9.6Kbs to 19.2Kbs between the WSGT CTFS
SSCs A&B, the GDIS MegaMux Plus Channels 7 (prime) and 9 (backup), and the GRGT LI
Switch Controller.

5.0 INSTALLATION/RELOCATION INSTRUCTIONS:

5.1 STGT Installation:


(Reference Figure 5-1 for specific point to point connections and Figure 5-2 for rack elevations)
5.1.1 Install new IF cabling from the SSA/KSA IF Switch chassis A9J11 A9J17 to the newly
modified I/O panel A1J24, 370MHz IF. See below for rack listing.
SGLT-1 1007, 1008, 1009, 1010
SGLT-2 1207, 1208, 1209, 1210
SGLT-3 1407, 1408, 1409, 1410
5.1.2 Relocate STGT IF Switch Controller (SISC) from 7709S A7 A10 to A10 A15 and re-label
associated cabling.
5.1.3 Install two FOTS transmitter chassis in rack 7709S-A1 and A4.
5.1.4 Install two LNA chassis in rack 7709S-A8 and A11.
5.1.5 Install fiber optics multiplexer in rack 7709S-A7.
5.1.6 Install new heliax cable tray hanger c-channel bracing along the SGLT SSA racks (AA32-
EE32, AA39-EE39, AA41-EE41, AA48-EE48, AA68-EE68, AA75-EE75), along the full
expanse behind rack 7709S (S50-EE50), and along the adjoining north cable tray (EE32-
EE75).
5.1.7 Install Heliax ¼” from SGLTs 1, 2, & 3 SSA A&B racks A1J24 to FOTS LNAs 7709S-A2 A8
and A5 A11 (12 total).
5.1.8 Install cabling from each LNA module to the FOTS transmitter chassis.
5.1.9 Install fiber optic cabling from each FOTS transmitter chassis (A2 A11, A5 A14) to the fiber
multiplexer (12 total) as per Figure 5-1.
5.1.10 Install single fiber optic cable from fiber multiplexer chassis to STGT IFL FOPP Circuit 115
rack 7101SA4-H2J1.
5.1.11 Install BCP FOTS module in rack 7104S-A3 CH-9 (C&S).
5.1.12 Install C&S cabling from rack 7709S-C1J2Jx to rack 7104S-A3 CH-9 transmit and receive
(C&S).
5.1.13 Install fiber optic cables (C&S) from FOTS rack 7104S-A3 CH-9 to FOPP Circuits 127 and
128, rack 7101SA4-J2J1 and 7101SA4-J2J2.
EC No. 8412CH1
Date: 4/2/2007 2/8/2006
Page 5 of 27
5.2 WSGT Installation:
(Reference Figure 5-1 for specific point to point connections and Figure 5-3 for rack elevation)
5.2.1 Install rack 7213W at floor location GCE O-33.
5.2.1.1 Install AC power cabling and receptacles providing 120V/20A prime and redundant
circuits from associated distribution panels.
5.2.1.2 Connect rack ground and GCE floor power.
5.2.1.3 Update Facilities power schedule.
5.2.2 Install new RG-400 IF cabling from SSA/KSA IF Switch chassis A9J11 J17 to the newly
modified I/O panel A1J24, 370MHz IF. See below for rack listing.
SGLT-4 1007, 1008, 1009, 1010
SGLT-5 1207, 1208, 1209, 1210
5.2.3 Install two FOTS receivers in rack 7213W-A3 A1 and A6 A4.
5.2.4 Install fiber optic demultiplexer in rack 7213W-A2 A7.
5.2.5 Install new patch panels (P/P) and SSAR-IF 32x32 Switch and associated Controller/Power
Supply chassis in the following locations:
SSAR-IF Switch 7213W-A10 A9
Controller/PS 7213W-A17 A16
P/P IN 1-16 7213W-A20 A19
P/P IN 17-32 7213W-A22 A21
P/P OUT 1-16 7213W-A24 A23
P/P OUT 17-32 7213W-A26 A25
5.2.6 Connect SSAR-IF Switch to Controller/Power Supply chassis using vender-supplied cables.
5.2.7 Install BCP FOTS module in rack 7104W-A3 CH-9 (C&S).
5.2.8 Install single fiber optic cable from WSGT IFL FOPP Circuit 115 7101WA2-H2J1 to fiber
amplifier demultiplexer 7213W-A1-IN A7Jx.
5.2.9 Install fiber optic cables from BCP (C&S) rack 7104W-A3 CH-9 to Circuits 127 and 128 rack
7101WA2-J2J1 and 7101WA2-J2J2.
5.2.10 Install C&S cable from BCP (C&S) 7104W-A3 CH-9 to SSAR-IF Switch 7213W-A17J4
USER CTRL.
5.2.11 Install new heliax cable tray hanger c-channel bracing along the SGLT SSA racks (Z18-
BB18, Z25-BB25, Z45-BB45, Z52-BB52) and the new rack 7213W (O34-P34).
5.2.12 Install Heliax ¼” from SGLTs 4 & 5 SSA A&B racks A1J24 to P/P (IN 17-32) 7213W-A22
A21 (8 total).
5.2.13 Interconnect P/P ports to their associated IF Switch input and output ports using RG-400.

5.3 GRGT Installation:


(Reference Figure 5-1 for specific point to point connections and Figure 5-5 for rack elevation)
5.3.1 Install new cabling from SSA/KSA IF Switch A9J11 J17 to the newly modified I/O panel
A1J24, 370MHz IF. See below for rack listing.
SGLT-6 1407, 1408, 1409, 1410
5.3.2 Install new patch panels (P/P) and SSAR-IF 16x16 Switch and associated Controller/Power
Supply chassis in the following locations:
SSAR-IF Switch 1421G-A13 7211G-A16
Controller/PS 1421G-A12 7211G-A19
P/P IN 1-16 1421G-A11 7211G-A22
P/P OUT 1-16 1421G-A10 7211G-A24
5.3.3 Connect SSAR-IF Switch to Controller/Power Supply chassis using vender-supplied cables.
5.3.4 Install Heliax ¼” from SGLT 6 SSA A&B racks A1J24 to P/P (IN 1-16) 7211G-A11 A22 (4
total).
5.3.5 Interconnect patchpanel ports to their associated IF Switch input and output ports using RG-
400.

6.0 DISPOSITION INSTRUCTIONS:


N/A
EC No. 8412CH1
Date: 4/2/2007 2/8/2006
Page 6 of 27
7.0 TESTING:

7.1 Pre-Tear Down Testing

7.1.1 Prior to removing the SSA/KSA IF Switch, perform a low data rate loop test. Verify that the
chassis performs within specifications.
7.1.2 Record the “Pre-Demod Out” level in the System Test Data Record.
7.1.3 Perform modification of SSA/KSA IF Switch, reference section 3.0.

7.2 Installation/Relocation Testing

7.2.1 After modifications to the SSA/KSA IF Switch, install the unit back into the SSA chain, and
perform a low data rate loop test.
7.2.2 Measure both the “Pre-Demod Out” and the new “370 MHz IF Out” at the rear panel (J11
J17) and record in the System Test Data Record.
7.2.3 Verify that the chassis performs within the same specifications as prior to modification.
7.2.4 Repeat the above for each chassis to be modified.

7.3 Equipment Testing


See System Test Data Record

7.4 System Testing


See System Test Data Record

7.5 Operational Acceptance Testing


See System Test Data Record

8.0 OPERATIONAL / MAINTENANCE INSTRUCTIONS:

Modifications to the SSA/KSA IF Switch Chassis, SSA Racks, SISC, GLISC, and CTFS SSCs will
require system time and will be performed during no-user timeframes. It is expected that the
modifications/post installation testing to the USS SSA/KSA IF Switch will require approximately two
hours per chassis. System testing will also be performed on a non-impacting basis.

9.0 DOCUMENTATION:

9.1 Essential:

9.1.1 MANUALS:
IF Switch O&M Manual
9.1.2 DRAWINGS:
N/A
9.2 Affected: See DUCS.

10.0 PARTS REQUIRED / SUPPLIED:

10.1 Logistics Supplied

ITEM QTY PART NO. DESCRIPTION MFG COST


1 1 ea. MS-4000-32X32-IF370- 32 x 32 Matrix IF Switch CrossPoint $95,720
AT-SDO
2 1 ea. MS-4000-16X16-IF370- 16 x 16 Matix IF Switch CrossPoint $68,995
AT-SDO
3 1 ea. Spares for MS-4000- Spares for 32 x 32 Matrix IF Switch CrossPoint $23,930
32X32-IF370
EC No. 8412CH1
Date: 4/2/2007 2/8/2006
Page 7 of 27
4 1 ea. Spares for MS-4000- Spares for 16 x 16 Matrix IF Switch CrossPoint $17,000
16X16-IF370
5 1 ea. HHCABHNYWEL Equipment Rack, 36” H&H Industrial $1,490
197836
6 250 ea. 1051664-1 SMA Connectors AMP $2,290
7 200 ft. 216-0310 RG-316/U coax cable Belden $184
8 50 ea. C-0205-6-T 6dB couplers, terminated RLC Electronics $10,450
9 1 ea. 91772A086 Screw, Machine, #2-56x1” (100) McMaster $3
10 1 ea. 91772A266 Screw, Machine, #2-56x1.25” (100) McMaster $8
11 3 ea. 91831A002 Nut, Nylon Lock, #2-56 (50) McMaster $39
12 2 ea. 94639A193 Standoff, Plastic, #2-1/4”x1/4” (100) McMaster $13
13 1 ea. 90945A705 Washer, Round, #2 (50) McMaster $8
14 50 ea. PE3573-12 Cable Asm, SMA(M) to SMA(M), 50 Pasternack $1,295
Ohm, RG316, 12”
15 50 ea. PE3835-12 Cable Asm, SMA(M) to SMA(F)-BH, Pasternack $1,626
50 Ohm, RG316, 12”
16 2300 ft. ETS1-50T Cable, 50 Ohm, 1/4" Heliax Superflex - Andrew $12,650
Continuous
17 1000 ft. RG400 Cable, 50 Ohm, Coaxial Amphenol $1,750
18 500 ft. CXN2363 Cable, Twinax Gore $2,750
19 28 ea. F083-S23AA0 (1.5m) Cable, FC-FC, SM, Simplex, OFNP Stonewall Cable $896
Plenum, 1.5m
20 1 ea. F083-S23AB0 (37m) Cable, FC-ST, SM, Simplex, Plenum, Stonewall Cable $76
37m
21 1 ea. F083-S23AB0 (28m) Cable, FC-ST, SM, Simplex, OFNP Stonewall Cable $65
Plenum, 28m
22 2 ea. F083-D23BB0 (9m) Cable, ST-ST, SM, Duplex, OFNP Stonewall Cable $158
Plenum, 9m
23 120 ea. 225345-6 Connector, TNC(M), for RG400 Amphenol $1,578
24 40 ea. F1PTM-HF Connector, TNC(M), for ETS1-50T Andrew $1,080
25 14 ea. 41EWS Connector, SMA(M), for ETS1-50T Andrew $952
26 28 ea. 122363 Connector, TNC(F)-BH, for RG400 Amphenol Connex $280
27 136 ea. 225532-3 Connector, SMA(M), for RG400 Amphenol $2,040
28 4 ea. PL75C-222 Connector, TRB(M), for CXN2363 Gore $79
29 2 ea. M24308/2-1 Connector, Sub-D 9 pin, (F) best source $27
30 2 ea. 745854-1 Backshell, for Sub-D 9 pin Conn. best source $10
31 2 ea. MS27467T11F35S Connector, 13 pin, Circular, (F) Amphenol $80
32 2 ea. M85049/3610N03 Backshell, for Circular Conn. Glenair $152
33 6 ea. JSI-32A/J5 Distribution Panel, 32 TNC Jacks Trompeter $2,493
34 100 ea. LP-50 Looping Plugs, 50 Ohm, fit JSI-32A Trompeter $2,046
35 16 ea. PC-36-50 Patch Cord, 50 Ohm, 36” Trompeter $405
36 30 ea. 3310T6 (P4100) Strut Channel, Unslotted, 13/16”x1- McMaster Carr $654
5/8”x10’
37 190 ea. P2034 Clamp, Strut Mount, 1-1/2” Unistrut $247
38 35 ea. P2030 Clamp, Strut Mount, 1” Unistrut $28
39 225 ea. P2860-33 Cap, End, Plastic, White Unistrut $270
40 Asm N/A FOTS & DWDM Assembly Ortel & Radiant $74,108
41 Asm N/A Amplifier Assembly Foxcom $11,180
42 2 ea. QOB120VH Circuit Breaker, 1 p, 120v220KAIC $96
43 2 ea. 5935-00-N92-0768 Cover, Receptacle SS $6
44 2 ea. 5975-00-939-5613 Device Holders $12
45 2 ea. 5935-01-302-2328 Receptacle, L5-20 Isolated Ground $52
46 500 ft. Wire, THHN 10AWG $50
47 10 ft. P-1000 Strut, Galvanized $20
48 1 ea. Cadweld, #90 $5
49 10 ft. Wire, #6 THHN CU Ground $5
50 1 ea. Lug, Compression #6 $5

Total $339,356

10.2 Engineering Supplied

EC No. 8412CH1
Date: 4/2/2007 2/8/2006
Page 8 of 27
ITEM QTY PART NO. NSN DESCRIPTION MFG COST
N/A
10.3 Spare Parts Provisioning

ITEM QTY PART NO. NSN DESCRIPTION MFG


N/A
10.4 Tools Required

ITEM QTY PART NO. NSN DESCRIPTION MFG


N/A

EC No. 8412CH1
Date: 4/2/2007 2/8/2006
Page 9 of 27
370 MHz 370 MHz 370 MHz
from SSA PTE to IF from SSA PTE
Downconverter IN Switch Downconverter IN

PS3 PS3

AT7 AT7
AT2

COUP
K1 K1
COUP1

COUP1
W119 W119
PS1 PS1

PRE 370 MHz PRE 370 MHz


MTG (FP)

MTG (FP)
Spec An

Spec An
DEMOD to IR DEMOD to IR
OUT OUT
(FP) (FP)

Before Modification After Modification

SSA/KSA IF Switch Modification


Figure 3-1a

EC No. 8412CH1
Date: 4/2/2007 2/8/2006
Page 10 of 27
FROM:
SSA Downconverter
370MHz
(Rear Panel)

AT-7 TO:
K1
Switch

S
PS-3

1
TO:
PRE DEMOD OUT
Existing
(Front Panel)
W119
AT-2

BEFORE MOD
FROM:
SSA Downconverter
370MHz
(Rear Panel)

AT-7 TO:
K1
EXISTING Switch

SPLITTER
2

PS-3
S

TO:
PRE DEMOD OUT
1

Existing
W119
(Front Panel)

TO:
(AT-2 Removed) IF Switch 370MHz
New
(Rear Panel J-17) J11

-6dB

NEW 6dB
COUPLER

IN OUT

AFTER MOD

SSA/KSA IF SWITCH
Coupler Installation
Figure 3-1b

EC No. 8412CH1
Date: 4/2/2007 2/8/2006
Page 11 of 27
J24
MDH
MDH
MDH

M DH
MDHH

MDH
DH
MD
MDH

MDH
DH
M

DH
M

M
MDH H
MDH
MDH
MDH
MD
MDH
MDH
M DH
MDH
M DH
M DH MDH
M
M DH
M DH
MDDH
M DH
MDH
M
MDH MDHH
MDH
DH
MDHH

MDH
MD H

MDH
MDDH

M DH
M

M DH
M DH
MDH
M DH

Locate approximately
2" from edges

New
SSAR-IF TNC Bulkhead A1 I/O PANEL
Connector Top Down View
MODIFICATION from Rack Rear

STGT---------------- WSGT---------------- GRGT----------------


S-1 SSA1A Rack 1007 S-4 SSA1A Rack 1007 S-6 SSA1A Rack 1407
S-1 SSA1B Rack 1008 S-4 SSA1B Rack 1008 S-6 SSA1B Rack 1408
S-1 SSA2A Rack 1009 S-4 SSA2A Rack 1009 S-6 SSA2A Rack 1409
S-1 SSA2B Rack 1010 S-4 SSA2B Rack 1010 S-6 SSA2B Rack 1410
S-2 SSA1A Rack 1207 S-5 SSA1A Rack 1207
S-2 SSA1B Rack 1208 S-5 SSA1B Rack 1208
S-2 SSA2A Rack 1209 S-5 SSA2A Rack 1209
S-2 SSA2B Rack 1210 S-5 SSA2B Rack 1210
S-3 SSA1A Rack 1407
S-3 SSA1B Rack 1408
S-3 SSA2A Rack 1409
S-3 SSA2B Rack 1410

RACK MODIFICATION LIST

Figure 3-2

EC No. 8412CH1
Date: 4/2/2007 2/8/2006
Page 12 of 27
EC-8412 STGT SSAR-IF Switch STATUS/CMD –
BCP-2200 FOTS (7104S) (IFL) ÅÆ STGT IF Switch Controller (7709S)

Connector Type Cable Type Connector Type Length


TRB CXN2363 Circular Approx. 100 ft.
PL75C-222 (x2) MS27467T11-F35S
Backshell
Cable No. MS85049-36-10N03
W67433 W67428

Cable Pair/
Pinout Suffix Color Pinout Remarks
Pin A White 1 Status Data (RX+)
Ring Black 2 Status Data (RX-)
Pin B White 3 Cmd Data (TX+)
Ring Black 4 Cmd Data (TX-)
Shield Shell Ground

7104S
PIN RX+ (STATUS DATA) WHT
A3-Ch9 1
RX-DATA
RING RX- (STATUS DATA) BLK
(from fiber) 2
7709S
PIN TX+ (CMD DATA) WHT C1J2
3
7104S
A3-Ch9 RING TX- (CMD DATA) BLK
4
TX-DATA
(to fiber) SHIELD/GROUND
13

TRB CIRCULAR, 13
PL75C-222 MS27467T11-F35S
for CXN2363 BACKSHELL
M85049-36-10N03

CABLE NO. EC-8412 STGT


LS FOTS IF SW
W67428
SSAR-IF SW CABLE TYPE CABLE LENGTH CONTROLLER
SUFFIX I/O PANEL
STATUS/CMD CXN2363 ~100 FT.
-A,B

W67433

STGT SSAR-IF Switch Status & Command


Figure 4-1

EC No. 8412CH1
Date: 4/2/2007 2/8/2006
Page 13 of 27
EC-8412 WSGT SSAR-IF Switch STATUS/CMD –
WSGT IF Switch (7213W) ÅÆ BCP-2200 FOTS (7104W) (IFL)

Connector Type Cable Type Connector Type Length


DE9S CXN2363 TRB Approx. 90 ft.
M24308/2-1 (x2) PL75C-222
Backshell
745854-1 Cable No.
W67436 W67431

Cable Pair/
Pinout Suffix Color Pinout Remarks
6 A White Pin Status Data (RX+)
1 Black Ring Status Data (RX-)
9 B White Pin Cmd Data (TX+)
4 Black Ring Cmd Data (TX-)
Shield Ground

WHT RX+ (STATUS DATA) PIN 7104W


6 A3-Ch9
BLK RX- (STATUS DATA) RING TX-DATA
1 (to fiber)
7213W WHT TX+ (CMD DATA) PIN
A16 9
USER CTRL 7104W
BLK TX- (CMD DATA) RING
4 A3-Ch9
A17J4 RX-DATA
SHIELD/GROUND
5 (from fiber)

DE9S (f) TRB


M24308/2-1 PL75C-222
BACKSHELL for CXN2363
745854-1

CABLE NO. EC-8412 WSGT


WSGT LS FOTS
W67431
SSAR-IF SW CABLE TYPE CABLE LENGTH SSAR-IF SW
SUFFIX
STATUS/CMD CXN2363 ~90 FT. CONTROLLER
-A,B

W67436

WSGT SSAR-IF Switch Status & Command


Figure 4-2
EC No. 8412CH1
Date: 4/2/2007 2/8/2006
Page 14 of 27
EC-8412 GRGT SSAR-IF Switch STATUS/CMD –
GRGT SSAR IF Switch (1421G7211G) ÅÆ GRGT LI Switch Controller (1457G)

Connector Type Cable Type Connector Type Length


DE9S CXN2363 Circular Approx. 25 ft.
M24308/2-1 (x2) MS27467T11-F35S
Backshell Backshell
745854-1 Cable No. MS85049-36-10N03
W67439 W67434

Cable Pair/
Pinout Suffix Color Pinout Remarks
6 A White 1 Status Data (RX+)
1 Black 2 Status Data (RX-)
9 B White 3 Cmd Data (TX+)
4 Black 4 Cmd Data (TX-)
Shield Shell Ground

RX+ (STATUS DATA) WHT


6 1
RX- (STATUS DATA) BLK
1 2
7211G TX+ (CMD DATA) WHT
A19 9 3
1457G
USER CTRL TX- (CMD DATA) BLK C1J6
4 4
SHIELD/GROUND
1421G-A12J4 5 13

CIRCULAR, 13
DE9S (f)
MS27467T11-F35S
M24308/2-1
BACKSHELL
BACKSHELL
M85049-36-10N03
745854-1

CABLE NO. EC-8412 GRGT


GRGT LI SW
W67434
SSAR-IF SW CABLE TYPE CABLE LENGTH CONTROLLER
SUFFIX
STATUS/CMD CXN2363 ~25 FT. I/O PANEL
-

W67439

GRGT SSAR-IF Switch Status & Command


Figure 4-3

EC No. 8412CH1
Date: 4/2/2007 2/8/2006
Page 15 of 27
7213W (LOC GCE O-33)

SGLT-1 SSA1A SGLT-1 SSA1B SGLT-1 SSA2A SGLT-1 SSA2B FIBER DEMUX FOTS RX SSAR-IF
RG-400 P/P (A19) RG-400 SWITCH (A9) RG-400 P/P (A23)
Rack 1007 Rack 1008 Rack 1009 Rack 1010 1:16 DWDM (A1)
(A7) IN 1-16 IN 32X32 OUT OUT 1-16
SMA(M)
SSA/KSA IF SSA/KSA IF SSA/KSA IF SSA/KSA IF W67308 W67320 S1-SSA1A W67332 W67364
SWITCH SWITCH SWITCH SWITCH Jx CH1J1 CH1J2 J1 J17 1 1 J1 J17
W67309 W67321 S1-SSA1B W67333 W67365
Jx CH2J1 CH2J2 J2 J18 2 2 J2 J18
W67310 W67322 S1-SSA2A W67334 W67366
A9J17 A9J17 A9J17 A9J17 Jx CH3J1 CH3J2 J3 J19 3 3 J3 J19
W67311 W67323 S1-SSA2B W67335 W67367
SMA(M) SMA(M) SMA(M) SMA(M) Jx CH4J1 CH4J2 J4 J20 4 4 J4 J20
W67312 W67324 S2-SSA1A W67336 W67368
Jx CH5J1 CH5J2 J5 J21 5 5 J5 J21
W67313 W67325 S2-SSA1B W67337 W67369
FC Jx CH6J1 CH6J2 J6 J22 6 6 J6 J22
RG-400 W67246 RG-400 W67247 RG-400 W67248 RG-400 W67249 Jx W67314 W67326 S2-SSA2A W67338 W67370
Jx CH7J1 CH7J2 J7 J23 7 7 J7 J23
W67315 W67327 S2-SSA2B W67339 W67371
Jx CH8J1 CH8J2 J8 J24 8 8 J8 J24
TNC(BH) TNC(BH) TNC(BH) TNC(BH) W67316 W67328 S3-SSA1A W67340 W67372
Jx CH1J1 CH1J2 J9 J25 9 9 J9 J25
W67317 W67329 S3-SSA1B W67341 W67373
A1J24 A1J24 A1J24 A1J24 Jx CH2J1 CH2J2 J10 J26 10 10 J10 J26
W67318 W67330 S3-SSA2A W67342 W67374
Jx CH3J1 CH3J2 J11 J27 11 11 J11 J27
W67319 W67331 S3-SSA2B W67343 W67375
TNC(M) TNC(M) TNC(M) TNC(M) Jx CH4J1 CH4J2 J12 J28 12 12 J12 J28
S4-SSA1A W67344 W67376
370MHz IF FC FC J13 J29 13 13 J13 J29
FIBER FOTS RX S4-SSA1B W67345 W67377
W67270 J14 J30 14 14 J14 J30
OPTIC (A4) S4-SSA2A W67346 W67378
W67271 J15 J31 15 15 J15 J31
S4-SSA2B W67347 W67379
W67272 J16 J32 16 16 J16 J32

INTERFACE
W67273

LOCAL
SGLT-2 SSA1A SGLT-2 SSA1B SGLT-2 SSA2A SGLT-2 SSA2B P/P (A21) P/P (A25)
Rack 1207 Rack 1208 Rack 1209 Rack 1210 IN 17-32 OUT 17-32
S5-SSA1A W67348 W67380
SSA/KSA IF SSA/KSA IF SSA/KSA IF SSA/KSA IF J1 J17 17 17 J1 J17
S5-SSA1B W67349 W67381
SWITCH SWITCH SWITCH SWITCH J2 J18 18 18 J2 J18
S5-SSA2A W67350 W67382
J3 J19 19 19 J3 J19
A9J17 A9J17 A9J17 A9J17 S5-SSA2B W67351 W67383
J4 J20 20 20 J4 J20
7709S W67352 W67384 J5
SMA(M) SMA(M) SMA(M) SMA(M) 7101S 7101W J21 21 21 J21
W67353 W67385
J22 22 22 J6 J22
W67354 W67386 J7
RG-400 W67250 RG-400 W67251 RG-400 W67252 RG-400 W67253 LNA FOTS TX FIBER MUX IFL IFL J23 23 23 J23
FOPP FOPP W67355 W67387
(A8) (A1) 16:1 DWDM J24 24 24 J8 J24
(A7) (A4) (A2) W67356 W67388
TNC(BH) TNC(BH) TNC(BH) TNC(BH) J25 25 25 J9 J25
S1-SSA1A
W67357 W67389
Jx Jx W67437 W67294 Jx J26 26 26 J10 J26
A1J24 A1J24 A1J24 A1J24 CH1J2 CH1J1 W67358 W67390
S1-SSA1B W67438 W67295 J27 27 27 J11 J27
Jx Jx CH2J2 CH2J1 Jx W67359 W67391
S1-SSA2A W67439 W67296 J28 28 28 J12 J28
TNC(M) TNC(M) TNC(M) TNC(M) Jx Jx CH3J2 CH3J1 Jx W67360 W67392
S1-SSA2B W67440 W67297 J29 29 29 J13 J29
Jx Jx CH4J2 CH4J1 Jx W67361 W67393
S2-SSA1A W67441 W67298 J30 30 30 J14 J30
Jx Jx CH5J2 CH5J1 Jx W67362 W67394
W67274 S2-SSA1B W67442 W67299 W67307 J31 31 31 J15 J31
Jx Jx CH6J2 CH6J1 Jx W67306 W67363 W67395
W67275 S2-SSA2A W67443 W67300 Jx 115 115 J32 32 32 J16 J32
Jx Jx CH7J2 CH7J1 Jx FC(SM) TNC(M) TNC(M) SMA(M) SMA(M) TNC(M)
W67276 S2-SSA2B W67444 W67301 H2J1 H2J1
Jx Jx CH8J2 CH8J1 Jx
W67277 S3-SSA1A W67445 W67302 FIBER
Jx Jx CH1J2 CH1J1 Jx FIBER IF SWITCH
S3-SSA1B W67446 W67303 OPTIC OPTIC
Jx Jx CH2J2 CH2J1 Jx PS/CNTR (A16)
S3-SSA2A W67447 W67304
SGLT-3 SSA1A SGLT-3 SSA1B SGLT-3 SSA2A SGLT-3 SSA2B S3-SSA2B
Jx Jx CH3J2 CH3J1 Jx 127 127
PWR OUT W67432 PWR IN
W67448 W67305 J2J1 J2J1
Rack 1407 Rack 1408 Rack 1409 Rack 1410 Jx Jx CH4J2 CH4J1 Jx USER MDROP-A W67433 CTRL-A
SMA(M) SMA(M) FC(SM) CTRL
CONTROL DE9S DE9S
SSA/KSA IF SSA/KSA IF SSA/KSA IF SSA/KSA IF LNA SMA(M) FOTS TX FC(SM) 128 128 & STATUS
SWITCH SWITCH SWITCH SWITCH (A4) FIBER (Vender Supplied Cables)
(A11) RG-400 J2J2 J2J2
OPTIC CXN2363
A9J17 A9J17 A9J17 A9J17 ST ST
7104W
SMA(M) SMA(M) SMA(M) SMA(M) IF SWITCH W67430 BCP FOTS W67431
CONTROLLER (A3)
I/O
RG-400 W67254 RG-400 W67255 RG-400 W67256 RG-400 W67257 CH9
P3CH2 C1J2 ST TX/RX TRB
TNC(BH) TNC(BH) TNC(BH) TNC(BH) MS13 CONTROL
A1J24 A1J24 A1J24 A1J24 & STATUS
7104S
TNC(M) TNC(M) TNC(M) TNC(M) BCP FOTS
W67428 (A3) W67429

CXN2363 CH9 SGLT-4 SSA1A SGLT-4 SSA1B SGLT-4 SSA2A SGLT-4 SSA2B SGLT-5 SSA1A SGLT-5 SSA1B SGLT-5 SSA2A SGLT-5 SSA2B
W67278 TX/RX Rack 1007 Rack 1008 Rack 1009 Rack 1010 Rack 1207 Rack 1208 Rack 1209 Rack 1210
W67279 TRB ST
W67280 SSA/KSA IF SSA/KSA IF SSA/KSA IF SSA/KSA IF SSA/KSA IF SSA/KSA IF SSA/KSA IF SSA/KSA IF
W67281 SWITCH SWITCH SWITCH SWITCH SWITCH SWITCH SWITCH SWITCH
HELIAX 1/4"
ETS1-50T A9J17 A9J17 A9J17 A9J17 A9J17 A9J17 A9J17 A9J17
SMA(M) SMA(M) SMA(M) SMA(M) SMA(M) SMA(M) SMA(M) SMA(M)

RG-400 W67258 RG-400 W67259 RG-400 W67260 RG-400 W67261 RG-400 W67262 RG-400 W67263 RG-400 W67264 RG-400 W67265

TNC(BH) TNC(BH) TNC(BH) TNC(BH) TNC(BH) TNC(BH) TNC(BH) TNC(BH)


A1J24 A1J24 A1J24 A1J24 A1J24 A1J24 A1J24 A1J24
TNC(M) TNC(M) TNC(M) TNC(M) TNC(M) TNC(M) TNC(M) TNC(M)

W67282 W67289
W67283 W67288
W67284 W67287
W67285 W67286
HELIAX 1/4" 370MHz IF
ETS1-50T

7211G

SSAR-IF
P/P (A22) SWITCH (A16) P/P (A24)
SGLT-6 SSA1A SGLT-6 SSA1B SGLT-6 SSA2A SGLT-6 SSA2B IN 1-16 IN 16X16 OUT OUT 1-16
Rack 1407 Rack 1408 Rack 1409 Rack 1410 370MHz IF S6-SSA1A
J1 W67396 1 1 W67412 J1
J17 J17
S6-SSA1B W67397 W67413
SSA/KSA IF SSA/KSA IF SSA/KSA IF SSA/KSA IF J2 J18 2 2 J2 J18
S6-SSA2A W67398 W67414
SWITCH SWITCH SWITCH SWITCH J3 J19 3 3 J3 J19
S6-SSA2B W67399 W67415
J4 J20 4 4 J4 J20
A9J17 A9J17 A9J17 A9J17 W67400 5 5 W67416 J5
TNC(M) J21 J21
SMA(M) SMA(M) SMA(M) SMA(M) W67401 W67417
J22 6 6 J6 J22
W67402 W67418

INTERFACE
J23 7 7 J7 J23
W67403 W67419

LOCAL
RG-400 W67266 RG-400 W67267 RG-400 W67268 RG-400 W67269 J24 8 8 J8 J24
W67404 W67420
J25 9 9 J9 J25
1457G W67405 W67421
TNC(BH) TNC(BH) TNC(BH) TNC(BH) J26 10 10 J10 J26
W67406 11 11 W67422 J11
J27 J27
A1J24 A1J24 A1J24 A1J24 W67407 W67423
GRGT TO J28 12 12 J12 J28
W67408 W67424
LI SWITCH WSGT CTFS J29 13 13 J13 J29
TNC(M) TNC(M) TNC(M) TNC(M) W67409 W67425
SSCs A&B J30 14 14 J14 J30
CONTROLLER via GDIS MM+ J31
W67410
15 15
W67426
J15 J31
W67290 (GLISC) J32
W67411
16 16
W67427
J16 J32
W67291 TNC(M) SMA(M) SMA(M) TNC(M)
W67292 RG-400 RG-400
W67293 IF SWITCH
HELIAX 1/4" LI SWITCH PS/CNTR (A19)
CONTROLLER
ETS1-50T
I/O C&S
W67434 USER
PWR OUT W67435
W67436
PWR IN SSAR-IF SERVICE
CTRL-A
P7CH6 C1J6
MS13 CXN2363 DE9S
CTRL MDROP-A
Vender EC-8412
Conn: MS27467T11-F35S DE9S Supplied
Shell: M85049-36-10N03
-L

EC No. 8412CH1
Date: 4/2/2007 2/8/2006
Page 16 of 27
7213W SSAR IF SWITCH (LOC GCE O-33)

SGLT-1 SSA1A SGLT-1 SSA1B SGLT-1 SSA2A SGLT-1 SSA2B Fiber Optic FIBER DEMUX FOTS1 RX SSAR-IF
RG-400 P/P (A20) RG-400 SWITCH (A10) RG-400 P/P (A24)
Rack 1007 Rack 1008 Rack 1009 Rack 1010 Amplifier 1:16 DWDM (A3)
(A1) (A2) SMA(M) 8' IN 1-16 7' IN 32X32 OUT 7' OUT 1-16
SSA/KSA IF SSA/KSA IF SSA/KSA IF SSA/KSA IF W67311 W67325 S1-SSA1A W67337 W67369
SWITCH SWITCH SWITCH SWITCH CH22 OPTIN CH22 RFOUT J1 J17 J1 1 1 J33 J1 J17
W67312 W67326 S1-SSA1B W67338 W67370
CH23 OPTIN CH23 RFOUT J2 J18 J2 2 2 J34 J2 J18
W67313 W67327 S1-SSA2A W67339 W67371
A9J11 A9J11 A9J11 A9J11 CH24 OPTIN CH24 RFOUT J3 J19 J3 3 3 J35 J3 J19
W67314 W67328 S1-SSA2B W67340 W67372
SMA(M) SMA(M) SMA(M) SMA(M) CH25 OPTIN CH25 RFOUT J4 J20 J4 4 4 J36 J4 J20
W67315 W67329 S2-SSA1A W67341 W67373
CH26 OPTIN CH26 RFOUT J5 J21 J5 5 5 J37 J5 J21
W67316 W67330 S2-SSA1B W67342 W67374
CH27 OPTIN CH27 RFOUT J6 J22 J6 6 6 J38 J6 J22
RG-400 W67246 RG-400 W67247 RG-400 W67248 RG-400 W67249 IN OUT W67310 COM W67317 W67331 S2-SSA2A W67343 W67375
CH28 OPTIN CH28 RFOUT J7 J23 J7 7 7 J39 J7 J23
W67318 W67332 S2-SSA2B W67344 W67376
6'4" FC/APC CH29 OPTIN CH29 RFOUT J8 J24 J8 8 8 J40 J8 J24
W67319 W67333 S3-SSA1A W67345 W67377
CH30 OPTIN CH30 RFOUT J9 J25 J9 9 9 J41 J9 J25
W67320 W67334 S3-SSA1B W67346 W67378
CH31 OPTIN CH31 RFOUT J10 J26 J10 10 10 J42 J10 J26
TNC(BH) TNC(BH) TNC(BH) TNC(BH) W67321 W67335 S3-SSA2A W67347 W67379
CH32 OPTIN CH32 RFOUT J11 J27 J11 11 11 J43 J11 J27
A1J24 A1J24 A1J24 A1J24 W67322 W67336 S3-SSA2B W67348 W67380
CH33 OPTIN CH33 RFOUT J12 J28 J12 12 12 J44 J12 J28
W67323 S4-SSA1A W67349 W67381
N-(M) N-(M) N-(M) N-(M) S1-SSA1A CH34 OPTIN CH34 RFOUT N/C J13 J29 J13 13 13 J45 J13 J29
W67324 S4-SSA1B W67350 W67382
W67270 S1-SSA1B CH35 OPTIN CH35 RFOUT N/C J14 J30 J14 14 14 J46 J14 J30
S4-SSA2A W67351 W67383
W67271 S1-SSA2A FC/APC J15 J31 J15 15 15 J47 J15 J31
S4-SSA2B W67352 W67384
S1-SSA2B FIBER FOTS2 RX J16 J32 J16 16 16 J48 J16 J32
W67272 (A6)
OPTIC

INTERFACE
W67273
(SM)

LOCAL
370MHz IF
3'
SGLT-2 SSA1A SGLT-2 SSA1B SGLT-2 SSA2A SGLT-2 SSA2B P/P (A22) P/P (A26)
Rack 1207 Rack 1208 Rack 1209 Rack 1210 IN 17-32 OUT 17-32
S5-SSA1A W67353 W67385
SSA/KSA IF SSA/KSA IF SSA/KSA IF SSA/KSA IF J1 J17 J17 17 17 J49 J1 J17
S5-SSA1B W67354 W67386
SWITCH SWITCH SWITCH SWITCH J2 J18 J18 18 18 J50 J2 J18
S5-SSA2A W67355 W67387
J3 J19 J19 19 19 J51 J3 J19
A9J11 A9J11 A9J11 A9J11 W67309 S5-SSA2B W67356 W67388
J4 J20 J20 20 20 J52 J4 J20
W67357 W67389 J5
SMA(M) SMA(M) SMA(M) SMA(M) J21 J21 21 21 J53 J21
7709S (Ka IF SWITCH Rack) 7101S 7101W W67358 W67390
J22 J22 22 22 J54 J6 J22
J23 W67359 J23 23 W67391 J7
RG-400 W67250 RG-400 W67251 RG-400 W67252 RG-400 W67253 23 J55 J23

?W65447?
FIBER MUX IFL IFL W67360 W67392

HELIAX 1/4"
FOTS1 TX

W67454

W65452
W67455

W65448

W65450
W65451
W65449
J24 J24 24 24 J56 J8 J24
6'4" (A2) 16:1 DWDM FOPP FOPP 80' 6' J25
W67361
J25 25 25 J57
W67393
J9 J25

ETS1-50T
(A8) (A4) (A2) W67362 W67394
W67442 W67294 J26 J26 26 26 J58 J10 J26
RFIN CH22 OPTOUT CH22 W67363 W67395
TNC(BH) TNC(BH) TNC(BH) TNC(BH) W67443 W67295 J27 J27 27 27 J59 J11 J27
RFIN CH23 OPTOUT CH23 W67364 W67396
A1J24 A1J24 A1J24 A1J24 W67444 OPTOUT W67296 J28 J28 28 28 J60 J12 J28
RFIN CH24 CH24 W67365 W67397
W67445 OPTOUT W67297 120' J29 J29 29 29 J61 J13 J29
N-(M) N-(M) N-(M) N-(M) RFIN CH25 CH25 W67366 W67398
S2-SSA1A W67446 W67298 J30 J30 30 30 J62 J14 J30
RFIN CH26 OPTOUT CH26 W67367 W67399
W67274 S2-SSA1B W67447 W67299 J31 J31 31 31 J63 J15 J31
RFIN CH27 OPTOUT CH27 W67308 W67368 W67400
W67275 S2-SSA2A W67448 W67300 COM 115 115 J32 J32 32 32 J64 J16 J32
RFIN CH28 OPTOUT CH28 FC(SM) TNC(M) TNC(M) SMA(M) SMA(M) TNC(M)
W67276 S2-SSA2B W67449 W67301 H2J1 H2J1
RFIN CH29 OPTOUT CH29
W67277 FIBER FIBER N-(F) IF SWITCH
OPTIC OPTIC N-(M) PS/CNTR (A17)
FOTS2 TX r b CIRC
SGLT-3 SSA1A SGLT-3 SSA1B SGLT-3 SSA2A SGLT-3 SSA2B 10' 127 127 W67437
(A5) J2J1 J2J1 90' DCPWR J3 J67 DCPWR IN
Rack 1407 Rack 1408 Rack 1409 Rack 1410 W67450 W67302 J4 J5
W67438 J65 CTRL/STATUS
RFIN CH30 OPTOUT CH30 CONTROL DE9S DE9S
SSA/KSA IF SSA/KSA IF SSA/KSA IF SSA/KSA IF W67451 OPTOUT W67303 b r
& STATUS 6'
RFIN CH31 CH31 128 128
SWITCH SWITCH SWITCH SWITCH W67452 W67304 J2J2
RFIN CH32 OPTOUT CH32 J2J2
W67453 OPTOUT W67305 ST ST CXN2363
A9J11 A9J11 A9J11 A9J11 RFIN CH33 CH33
OPTOUT W67306 7104W
N/C RFIN CH34 CH34
N-(M)
N-(F)
SMA(M) SMA(M) SMA(M) SMA(M) W67307 30' W67435 BCP FOTS W67436
N/C RFIN CH35 OPTOUT CH35 b
FC/APC (A3) RCV
W67254 W67255 W67256 W67257 SMA(M) FIBER r
RG-400 RG-400 RG-400 RG-400 CH9 TX
HELIAX 1/4" OPTIC
6'4" ETS1-50T (SM) 3'
ST TX/RX TRB
IF SWITCH
TNC(BH) TNC(BH) TNC(BH) TNC(BH) CONTROLLER
A1J24 A1J24 A1J24 A1J24 I/O 30'
N-(M) N-(M) N-(M) N-(M) P3CH2 C1J2
S3-SSA1A
CONTROL MS13
SGLT-4 SSA1A SGLT-4 SSA1B SGLT-4 SSA2A SGLT-4 SSA2B SGLT-5 SSA1A SGLT-5 SSA1B SGLT-5 SSA2A SGLT-5 SSA2B
W67278 S3-SSA1B
S3-SSA2A & STATUS 7104S W67434 Rack 1007 Rack 1008 Rack 1009 Rack 1010 Rack 1207 Rack 1208 Rack 1209 Rack 1210
W67279 BCP FOTS
S3-SSA2B b
W67280
120' RCV (A3) SSA/KSA IF SSA/KSA IF SSA/KSA IF SSA/KSA IF SSA/KSA IF SSA/KSA IF SSA/KSA IF SSA/KSA IF
W67281 W67433 r SWITCH SWITCH SWITCH SWITCH SWITCH SWITCH SWITCH SWITCH
TX CH9
HELIAX 1/2" TX/RX
HL4RP-50 TRB ST A9J11 A9J11 A9J11 A9J11 A9J11 A9J11 A9J11 A9J11
CXN2363
SMA(M) SMA(M) SMA(M) SMA(M) SMA(M) SMA(M) SMA(M) SMA(M)
100'
RG-400 W67258 RG-400 W67259 RG-400 W67260 RG-400 W67261 RG-400 W67262 RG-400 W67263 RG-400 W67264 RG-400 W67265
6'4" 6'4"

TNC(BH) TNC(BH) TNC(BH) TNC(BH) TNC(BH) TNC(BH) TNC(BH) TNC(BH)


A1J24 A1J24 A1J24 A1J24 A1J24 A1J24 A1J24 A1J24
N-(M) N-(M) N-(M) N-(M) N-(M) N-(M) N-(M) N-(M)
W67282 W67289
W67283 W67288
W67284 W67287
W67285 W67286
HELIAX 1/2" 370MHz IF
HL4RP-50

90'

1421G (USS-SSA 1&2 RTN-A)

SSAR-IF
P/P (A11) SWITCH (A13) P/P (A10)
SGLT-6 SSA1A SGLT-6 SSA1B SGLT-6 SSA2A SGLT-6 SSA2B IN 1-16 IN 16X16 OUT OUT 1-16
Rack 1407 Rack 1408 Rack 1409 Rack 1410 370MHz IF S6-SSA1A W65453 J1 J17 W67401 W67417
J1 1 1 J17 J1 J17
S6-SSA1B W65454 W67402 W67418
SSA/KSA IF SSA/KSA IF SSA/KSA IF SSA/KSA IF J2 J18 J2 2 2 J18 J2 J18
S6-SSA2A W65455 W67403 W67419
SWITCH SWITCH SWITCH SWITCH J3 J19 J3 3 3 J19 J3 J19
S6-SSA2B W65456 W67404 W67420
J4 J20 J4 4 4 J20 J4 J20
A9J11 A9J11 A9J11 A9J11 J21 W67405 J5 5 W67421 J5
5 J21 J21

N-(M)
N-(F)
TNC(M) W67406 W67422
SMA(M) SMA(M) SMA(M) SMA(M) J22 J6 6 6 J22 J6 J22
W67407 W67423

INTERFACE
J23 J7 7 7 J23 J7 J23

HELIAX 1/4"
ETS1-50T
W67408 W67424

LOCAL
RG-400 W67266 RG-400 W67267 RG-400 W67268 RG-400 W67269 J24 J8 8 8 J24 J8 J24
W67409 W67425
J25 J9 9 9 J25 J9 J25
6'4" 1457G 8' J26
W67410
J10 10 10 J26
W67426
J10 J26
W67411 W67427
J27 J11 11 11 J27 J11 J27
TNC(BH) TNC(BH) TNC(BH) TNC(BH) W67412 W67428
GRGT TO J28 J12 12 12 J28 J12 J28
W67413 W67429
A1J24 A1J24 A1J24 A1J24 LI SWITCH WSGT CTFS J29 J13 13 13 J29 J13 J29
SSCs A&B J30 W67414 W67430
J14 14 14 J30 J14 J30
N-(M) N-(M) N-(M) N-(M) CONTROLLER via GDIS MM+ J31
W67415
J15 15 15 J31
W67431 J15 J31
W67290 (GLISC) J32 W67416
J16 16 16 J32
W67432 J16 J32
W67291 TNC(M) SMA(M) SMA(M) TNC(M)
W67292 RG-400 RG-400
IF SWITCH 6' 6'
W67293 HELIAX 1/2" LI SWITCH PS/CNTR (A12) CIRC
HL4RP-50 CONTROLLER
I/O
CTRL/STATUS
W67439
DCPWR J3
W67440
W67441
J35 DCPWR IN SSAR-IF SERVICE
65' J33 CTRL/STATUS
P7CH6 C1J6
MS13 CXN2363 DE9S
J4 J5
DE9S EC-8412
6'
Conn: MS27467T11-F35S 40'
Shell: M85049-36-10N03

Figure 5-1
EC No. 8412CH1
Date: 4/2/2007 2/8/2006
Page 17 of 27
NEW
SSAR-IF
EQUIP

STGT IF SWITCH
CONTROLLER
(SISC)
RELOCATED

BEFORE AFTER

EC No. 8412CH1
Date: 4/2/2007 2/8/2006
Page 18 of 27
NEW
SSAR-IF
EQUIP

STGT IF
SWITCH
CONTROLLER
(SISC)
RELOCATED

BEFORE AFTER

STGT Rack 7709S


Figure 5-2

EC No. 8412CH1
Date: 4/2/2007 2/8/2006
Page 19 of 27
EC No. 8412CH1
Date: 4/2/2007 2/8/2006
Page 20 of 27
NEW

WSGT Rack 7213W


Figure 5-3

EC No. 8412CH1
Date: 4/2/2007 2/8/2006
Page 21 of 27
A19

A21

A23

A25

Rack 7213W

EC No. 8412CH1
Date: 4/2/2007 2/8/2006
Page 22 of 27
A20

A22

A24

A26

Rack 7213W

WSGT Patch Panel Layout


Figure 5-4

EC No. 8412CH1
Date: 4/2/2007 2/8/2006
Page 23 of 27
NEW
SSAR-IF
EQUIP

BEFORE AFTER

EC No. 8412CH1
Date: 4/2/2007 2/8/2006
Page 24 of 27
NEW
SSAR-IF
EQUIP

BEFORE AFTER

GRGT Rack 1421G 7211G


Figure 5-5

EC No. 8412CH1
Date: 4/2/2007 2/8/2006
Page 25 of 27
A22

A24

Rack 7211G

EC No. 8412CH1
Date: 4/2/2007 2/8/2006
Page 26 of 27
A11

A10

Rack 1421G

GRGT Patch Panel Layout


Figure 5-6

EC No. 8412CH1
Date: 4/2/2007 2/8/2006
Page 27 of 27
EC #: 8412CH1 DOCUMENTATION UPGRADE CONTROL SHEET COG: Mark Hibner
Closed Date
Document/ W/O Out For
Drawing No. Document Title EO DCN REV NEW WO # Submitted Review Released
530-WSC-0042 WSC Station Handbook E D R N5326 3/7/2007
530-WSC-0053 WSC GCE Handbook E D R N5327 3/7/2007
WSC-RSD-0092 WSC SSARIF FOTS RSD E D R N4587 2/21/2006 2/28/2006 3/2/2006
530-WSC-LOP-III BK-1 LOP Operations DIS E D R N5277 2/22/2007 3/2/2007 3/28/2007
500-ME-22237 IF Switch O&M Manual Rev A E D R NL1231 2/27/2007 ? 3/1/2007
STGT-HE-06-1 BK-1 WSC HW to SW ICD E D R N5278 2/23/2007
WSCCABLE WSC Cable Database E D R N5033 10/11/2006 10/14/2006
6544K011.dwg STGT Rack 7709 Elevation E D R N107-027 2/23/2007
TBD WSGT Rack 7213 Elevation E D R N107-029 2/23/2007
TBD WSGT Rack 7213-A20 P/P E D R N107-028 2/23/2007
TBD WSGT Rack 7213-A22 P/P E D R N107-028 2/23/2007
TBD WSGT Rack 7213-A24 P/P E D R N107-028 2/23/2007
TBD WSGT Rack 7213-A26 P/P E D R N107-028 2/23/2007
98059.dwg GRGT Rack 1421 Elevation E D R N107-030 2/26/2007
TBD GRGT Rack 1421-A11 P/P E D R N107-031 2/26/2007
TBD GRGT Rack 1421-A10 P/P E D R N107-031 2/26/2007
GF-WSC-1547432 STGT Tech Floor Layout E D R N107-032 2/26/2007
GF-WSC-1547444 WSGT Tech Floor Layout E D R N107-033 2/26/2007
E D R N
E D R N
E D R N
E D R N
E D R N
E D R N
E D R N
E D R N
E D R N
E D R N
E D R N
E D R N

Printed: 3/29/2007 Version 12/1/1998 Last Modified: 3/29/2007


8412CH1
EC # _________ HARDWARE UPGRADE CONTROL SHEET 1
Page _________

NEMS &/or NENS TAG DESCRIPTION HW REV # CHIP IMPLEMENTED TEST CM


Rack
Chassis or Card S/N PART/DRAWING # FROM/TO LOCATION BY/DATE PASSED VERIFICATION

N/A Modified by
G04831 SSA/KSA IF SWITCH S1SSA1A N/A Y
1007S M. Hibner
AGD1015 47-286050G2 5/25/06

N/A Modified by
G04818 SSA/KSA IF SWITCH S1SSA1B N/A Y
1008S M. Hibner
AGD1003 47-286050G2 5/25/06

N/A Modified by
G04588 SSA/KSA IF SWITCH S1SSA2A N/A Y
1009S M. Hibner
AGD1013 47-286050G2 5/31/06

N/A Modified by
G04576 SSA/KSA IF SWITCH S1SSA2B N/A Y
1010S M. Hibner
AGD1001 47-286050G2 5/31/06

N/A Modified by
G04804 SSA/KSA IF SWITCH S1KSA1A N/A Y
1011S M. Hibner
AGD1012 47-286050G1 7/20/06

N/A Modified by
G04795 SSA/KSA IF SWITCH S1KSA1B N/A Y
1013S M. Hibner
AGD0002 47-286050G1 7/20/06

N/A Modified by
G04612 SSA/KSA IF SWITCH S1KSA2A N/A Y
1014S M. Hibner
AGD0034 47-286050G1 7/27/06

N/A Modified by
G04598 SSA/KSA IF SWITCH S1KSA2B N/A Y
1016S M. Hibner
AGD0031 47-286050G1 7/27/06

N/A Modified by
G05700 SSA/KSA IF SWITCH S2SSA1A N/A Y
1207S M. Hibner
AGD1011 47-286050G2 6/7/06

N/A Modified by
G05685 SSA/KSA IF SWITCH S2SSA1B N/A Y
1208S M. Hibner
AGD1037 47-286050G2 6/7/06
N/A Modified by
G05465 SSA/KSA IF SWITCH S2SSA2A N/A Y
1209S M. Hibner
AGD1035 47-286050G2 5/17/06

N/A Modified by
G05452 SSA/KSA IF SWITCH S2SSA2B N/A Y
1210S M. Hibner
AGD1033 47-286050G2 5/17/06

WSC-0111 REV H (12/04)


8412CH1
EC # _________ HARDWARE UPGRADE CONTROL SHEET 2
Page _________

NEMS &/or NENS TAG DESCRIPTION HW REV # CHIP IMPLEMENTED TEST CM


Rack
Chassis or Card S/N PART/DRAWING # FROM/TO LOCATION BY/DATE PASSED VERIFICATION

N/A Modified by
G05673 SSA/KSA IF SWITCH S2KSA1A N/A Y
1211S M. Hibner
AGD0037 47-286050G1 6/8/06

N/A Modified by
G05655 SSA/KSA IF SWITCH S2KSA1B N/A Y
1213S M. Hibner
AGD0039 47-286050G1 6/8/06

N/A Modified by
G05485 SSA/KSA IF SWITCH S2KSA2A N/A Y
1214S M. Hibner
AGD0042 47-286050G1 6/8/06

N/A Modified by
G05468 SSA/KSA IF SWITCH S2KSA2B N/A Y
1216S M. Hibner
AGD0038 47-286050G1 6/8/06

N/A Modified by
G05906 SSA/KSA IF SWITCH S3SSA1A N/A Y
1407S M. Hibner
AGD1010 47-286050G2 6/21/06

N/A Modified by
G05889 SSA/KSA IF SWITCH S3SSA1B N/A Y
1408S M. Hibner
AGD1014 47-286050G2 6/21/06

N/A Modified by
G05730 SSA/KSA IF SWITCH S3SSA2A N/A Y
1409S M. Hibner
AGD1006 47-286050G2 6/21/06

N/A Modified by
G05715 SSA/KSA IF SWITCH S3SSA2B N/A Y
1410S M. Hibner
AGD1012 47-286050G2 6/21/06

N/A Modified by
G05879 SSA/KSA IF SWITCH S3KSA1A N/A Y
1411S M. Hibner
AGD0040 47-286050G1 6/22/06

N/A Modified by
G05861 SSA/KSA IF SWITCH S3KSA1B N/A Y
1413S M. Hibner
AGD0011 47-286050G1 6/22/06
N/A Modified by
G05756 SSA/KSA IF SWITCH S3KSA2A N/A Y
1414S M. Hibner
AGD0032 47-286050G1 6/22/06

N/A Modified by
G05739 SSA/KSA IF SWITCH S3KSA2B N/A Y
1416S M. Hibner
AGD0004 47-286050G1 6/22/06

WSC-0111 REV H (12/04)


8412CH1
EC # _________ HARDWARE UPGRADE CONTROL SHEET 3
Page _________

NEMS &/or NENS TAG DESCRIPTION HW REV # CHIP IMPLEMENTED TEST CM


Rack
Chassis or Card S/N PART/DRAWING # FROM/TO LOCATION BY/DATE PASSED VERIFICATION

N/A Modified by
G02175 SSA/KSA IF SWITCH S4SSA1A N/A Y
1007W M. Hibner
AGD1007 47-286050G2 5/8/06

N/A Modified by
G02164 SSA/KSA IF SWITCH S4SSA1B N/A Y
1008W M. Hibner
AGD1002 47-286050G2 5/8/06

N/A Modified by
G01971 SSA/KSA IF SWITCH S4SSA2A N/A Y
1009W M. Hibner
AGD1004 47-286050G2 4/25/06

N/A Modified by
G01959 SSA/KSA IF SWITCH S4SSA2B N/A Y
1010W M. Hibner
AGD1009 47-286050G2 4/27/06

N/A Modified by
G02157 SSA/KSA IF SWITCH S4KSA1A N/A Y
1011W M. Hibner
AGD0001 47-286050G1 7/21/06

N/A Modified by
G02144 SSA/KSA IF SWITCH S4KSA1B N/A Y
1013W M. Hibner
AGD0008 47-286050G1 7/21/06

N/A Modified by
G01993 SSA/KSA IF SWITCH S4KSA2A N/A Y
1014W M. Hibner
AGD0003 47-286050G1 4/27/06

N/A Modified by
G01980 SSA/KSA IF SWITCH S4KSA2B N/A Y
1016W M. Hibner
AGD0041 47-286050G1 4/27/06

N/A Modified by
G03008 SSA/KSA IF SWITCH S5SSA1A N/A Y
1207W M. Hibner
AGD1008 47-286050G2 5/9/06

N/A Modified by
G02995 SSA/KSA IF SWITCH S5SSA1B N/A Y
1208W M. Hibner
AGD1005 47-286050G2 5/9/06
N/A Modified by
G02787 SSA/KSA IF SWITCH S5SSA2A N/A Y
1209W M. Hibner
AGD1036 47-286050G2 5/15/06

N/A Modified by
G02775 SSA/KSA IF SWITCH S5SSA2B N/A Y
1210W M. Hibner
AGD1016 47-286050G2 5/15/06

WSC-0111 REV H (12/04)


8412CH1
EC # _________ HARDWARE UPGRADE CONTROL SHEET 4
Page _________

NEMS &/or NENS TAG DESCRIPTION HW REV # CHIP IMPLEMENTED TEST CM


Rack
Chassis or Card S/N PART/DRAWING # FROM/TO LOCATION BY/DATE PASSED VERIFICATION

N/A Modified by
G02987 SSA/KSA IF SWITCH S5KSA1A N/A Y
1211W M. Hibner
AGD0007 47-286050G1 5/23/06

N/A Modified by
G02973 SSA/KSA IF SWITCH S5KSA1B N/A Y
1213W M. Hibner
AGD0005 47-286050G1 5/23/06

N/A Modified by
G02809 SSA/KSA IF SWITCH S5KSA2A N/A Y
1214W M. Hibner
AGD0033 47-286050G1 5/23/06

N/A Modified by
G02797 SSA/KSA IF SWITCH S5KSA2B N/A Y
1216W M. Hibner
AGD0006 47-286050G1 5/23/06

N/A Modified by
G52324 SSA/KSA IF SWITCH S6SSA1A N/A Y
1407G B. Taylor
AGD1034 47-286050G2 8/2/06

N/A Modified by
G52339 SSA/KSA IF SWITCH S6SSA1B N/A Y
1408G B. Taylor
AGD1038 47-286050G2 8/2/06

N/A Modified by
G72609 SSA/KSA IF SWITCH S6SSA2A N/A Y
1409G B. Taylor
AGD1040 47-286050G2 8/1/06

N/A Modified by
G72621 SSA/KSA IF SWITCH S6SSA2B N/A Y
1410G B. Taylor
AGD1039 47-286050G2 8/1/06

N/A Modified by
G52347 SSA/KSA IF SWITCH S6KSA1A N/A Y
1411G B. Taylor
AGD0044 47-286050G1 8/3/06

N/A Modified by
G52364 SSA/KSA IF SWITCH S6KSA1B N/A Y
1413G B. Taylor
AGD0043 47-286050G1 8/3/06
N/A Modified by
G72631 SSA/KSA IF SWITCH S6KSA2A N/A Y
1414G B. Taylor
AGD0013 47-286050G1 8/3/06

N/A Modified by
G52535 SSA/KSA IF SWITCH S6KSA2B N/A Y
1416G B. Taylor
AGD0009 47-286050G1 8/3/06

WSC-0111 REV H (12/04)


8412CH1
EC # _________ HARDWARE UPGRADE CONTROL SHEET 5
Page _________

NEMS &/or NENS TAG DESCRIPTION HW REV # CHIP IMPLEMENTED TEST CM


Rack
Chassis or Card S/N PART/DRAWING # FROM/TO LOCATION BY/DATE PASSED VERIFICATION

N/A Installed by
G07880 SSAR-IF Rack N/A N/A
7213W J. Pino
Loc GCE O-33 4/6/06

N/A Installed by
G75039 Fiber Amplifier N/A Y
7213W K. Vick
(A1) 10/5/06

N/A Installed by
G75045 FOTS Tx, 1 of 2 N/A Y
7709S K. Vick
(A2) 10/5/06

N/A Installed by
G75046 FOTS Tx, 2 of 2 N/A Y
7709S K. Vick
(A5) 10/5/06

N/A Installed by
None Fiber Mux 16:1 N/A Y
7709S K. Vick
(A7) 10/5/06

N/A Modified by
G04516 BCP FOTS, CH9 CCA N/A Y
7104S M. Hibner
(A3) 9/25/06

N/A Modified by
G01895 BCP FOTS, CH9 CCA N/A Y
7104W M. Hibner
(A3) 9/25/06

N/A Installed by
None Fiber Demux 16:1 N/A Y
7213W K. Vick
(A7) 10/5/06

N/A Installed by
G75047 FOTS Rcv, 1 of 2 N/A Y
7213W K. Vick
(A3) 10/5/06

N/A Installed by
G75048 FOTS Rcv, 2 of 2 N/A Y
7213W K. Vick
(A6) 10/5/06
N/A Installed by
None SSAR IF Switch Controller/PS, 32x32 N/A N/A
7213W J. Pino
(A16) 4/6/06

N/A Installed by
G08624 SSAR IF Switch Matrix, 32x32 N/A N/A
7213W J. Pino
(A9) 4/6/06

WSC-0111 REV H (12/04)


8412CH1
EC # _________ HARDWARE UPGRADE CONTROL SHEET 6
Page _________

NEMS &/or NENS TAG DESCRIPTION HW REV # CHIP IMPLEMENTED TEST CM


Rack
Chassis or Card S/N PART/DRAWING # FROM/TO LOCATION BY/DATE PASSED VERIFICATION

N/A Installed by
None SSAR IF Switch Controller/PS, 16x16 N/A Y
1421G C. Baxter
(A12) 1/4/07

N/A Installed by
G08612 SSAR IF Switch Matrix, 16x16 N/A Y
1421G C. Baxter
(A13) 1/4/07

N/A Modified by
G04812 Rack, SGLT-1 SSA1A N/A Y
1007S M. Hibner
47-285460G1/6544031 5/25/06

N/A Modified by
G04812 Rack, SGLT-1 SSA1B N/A Y
1008S M. Hibner
47-285460G1/6544031 5/25/06

N/A Modified by
G04571 Rack, SGLT-1 SSA2A N/A Y
1009S M. Hibner
47-285460G1/6544126 5/31/06

N/A Modified by
G04571 Rack, SGLT-1 SSA2B N/A Y
1010S M. Hibner
47-285460G1/6544126 5/31/06

N/A Modified by
G05680 Rack, SGLT-2 SSA1A N/A Y
1207S M. Hibner
47-285460G1/6544031 6/7/06

N/A Modified by
G05680 Rack, SGLT-2 SSA1B N/A Y
1208S M. Hibner
47-285460G1/6544031 6/7/06

N/A Modified by
G05446 Rack, SGLT-2 SSA2A N/A Y
1209S M. Hibner
47-285460G1/6544126 5/17/06

N/A Modified by
G05446 Rack, SGLT-2 SSA2B N/A Y
1210S M. Hibner
47-285460G1/6544126 5/17/06
N/A Modified by
G05895 Rack, SGLT-3 SSA1A N/A Y
1407S M. Hibner
47-285460G1/6544031 6/21/06

N/A Modified by
G05895 Rack, SGLT-3 SSA1B N/A Y
1408S M. Hibner
47-285460G1/6544031 6/21/06

WSC-0111 REV H (12/04)


8412CH1
EC # _________ HARDWARE UPGRADE CONTROL SHEET 7
Page _________

NEMS &/or NENS TAG DESCRIPTION HW REV # CHIP IMPLEMENTED TEST CM


Rack
Chassis or Card S/N PART/DRAWING # FROM/TO LOCATION BY/DATE PASSED VERIFICATION

N/A Modified by
G05710 Rack, SGLT-3 SSA2A N/A Y
1409S M. Hibner
47-285460G1/6544126 6/21/06

N/A Modified by
G05710 Rack, SGLT-3 SSA2B N/A Y
1410S M. Hibner
47-285460G1/6544126 6/21/06

N/A Modified by
G02159 Rack, SGLT-4 SSA1A N/A Y
1007W M. Hibner
47-285460G1/6544031 5/8/06

N/A Modified by
G02159 Rack, SGLT-4 SSA1B N/A Y
1008W M. Hibner
47-285460G1/6544031 5/8/06

N/A Modified by
G01954 Rack, SGLT-4 SSA2A N/A Y
1009W M. Hibner
47-285460G1/6544126 4/25/06

N/A Modified by
G01954 Rack, SGLT-4 SSA2B N/A Y
1010W M. Hibner
47-285460G1/6544126 4/27/06

N/A Modified by
G02990 Rack, SGLT-5 SSA1A N/A Y
1207W M. Hibner
47-285460G1/6544031 5/9/06

N/A Modified by
G02990 Rack, SGLT-5 SSA1B N/A Y
1208W M. Hibner
47-285460G1/6544031 5/9/06

N/A Modified by
G02770 Rack, SGLT-5 SSA2A N/A Y
1209W M. Hibner
47-285460G1/6544126 5/15/06

N/A Modified by
G02770 Rack, SGLT-5 SSA2B N/A Y
1210W M. Hibner
47-285460G1/6544126 5/15/06
N/A Modified by
G52336 Rack, SGLT-6 SSA1A N/A Y
1407G B. Taylor
47-285460G1/6544031 8/2/06

N/A Modified by
G52336 Rack, SGLT-6 SSA1B N/A Y
1408G B. Taylor
47-285460G1/6544031 8/2/06

WSC-0111 REV H (12/04)


8412CH1
EC # _________ HARDWARE UPGRADE CONTROL SHEET 8
Page _________

NEMS &/or NENS TAG DESCRIPTION HW REV # CHIP IMPLEMENTED TEST CM


Rack
Chassis or Card S/N PART/DRAWING # FROM/TO LOCATION BY/DATE PASSED VERIFICATION

N/A Modified by
G52544 Rack, SGLT-6 SSA2A N/A Y
1409G B. Taylor
47-285460G1/6544126 8/1/06

N/A Modified by
G52544 Rack, SGLT-6 SSA2B N/A Y
1410G B. Taylor
47-285460G1/6544126 8/1/06

N/A Modified by
N/A STGT CTFS SSC-A FW to Y
1057S 5.614 L. Patti
1/4/07

N/A Modified by
N/A STGT CTFS SSC-B FW to Y
1059S 5.614 L. Patti
1/4/07

N/A Modified by
N/A IF SWITCH CONTROLLER N/A Y
7709S W. Borchardt
1/4/07

N/A Modified by
G52287 GUAM LI SWITCH CONTROLLER N/A Y
1457G W. Borchardt
1/4/07

N/A Modified by
G05343 RACK, Ka IF N/A N/A
7709S K. Vick
6544K011 10/5/06

N/A Modified by
G52427 RACK, SSA1 & SSA2 RTN-A N/A N/A
1421G C. Baxter
47-285540G1 / 98059 1/4/07

N/A Modified by
WSGT CTFS SSC-A FW to Y
1057W 5.614 L. Patti
SN-P203 1/4/07

N/A Modified by
WSGT CTFS SSC-B FW to Y
1059W 5.614 L. Patti
SN-P204 1/4/07

WSC-0111 REV H (12/04)


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
65447 W M/T W67284 N(F) F1PNF-BH 7213-A20J15 TNC(M) F1PTM S4-SA2A 370MHz IF to FOTS Cable Lengths
(7213W)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD BLK HELIAX ETS1-50T 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
65448 W M/T W67285 N(F) F1PNF-BH 7213-A20J16 TNC(M) F1PTM S4-SA2B 370MHz IF to FOTS Cable Lengths
(7213W)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD BLK HELIAX ETS1-50T 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
65449 W M/T W67286 N(F) F1PNF-BH 7213-A22J1 TNC(M) F1PTM S5-SA1A 370MHz IF to FOTS Cable Lengths
(7213W)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD BLK HELIAX ETS1-50T 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
65450 W M/T W67287 N(F) F1PNF-BH 7213-A22J2 TNC(M) F1PTM S5-SA1B 370MHz IF to FOTS Cable Lengths
(7213W)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD BLK HELIAX ETS1-50T 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
65451 W M/T W67288 N(F) F1PNF-BH 7213-A22J3 TNC(M) F1PTM S5-SA2A 370MHz IF to FOTS Cable Lengths
(7213W)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD BLK HELIAX ETS1-50T 8412 6

Date Printed: 3/29/07 Page 1 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
65452 W M/T W67289 N(F) F1PNF-BH 7213-A22J4 TNC(M) F1PTM S5-SA2B 370MHz IF to FOTS Cable Lengths
(7213W)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD BLK HELIAX ETS1-50T 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
65453 G M/T W67290 N(F) F1PNF-BH 1421-A11J1 TNC(M) F1PTM S6-SA1A 370MHz IF to FOTS Cable Lengths
(1421G)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD BLK HELIAX ETS1-50T 8412 8

SITE
W# Su S W G From From Conn PN To To Conn PN Function
65454 G M/T W67291 N(F) F1PNF-BH 1421-A11J2 TNC(M) F1PTM S6-SA1B 370MHz IF to FOTS Cable Lengths
(1421G)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD BLK HELIAX ETS1-50T 8412 8

SITE
W# Su S W G From From Conn PN To To Conn PN Function
65455 G M/T W67292 N(F) F1PNF-BH 1421-A11J3 TNC(M) F1PTM S6-SA2A 370MHz IF to FOTS Cable Lengths
(1421G)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD BLK HELIAX ETS1-50T 8412 8

SITE
W# Su S W G From From Conn PN To To Conn PN Function
65456 G M/T W67293 N(F) F1PNF-BH 1421-A11J4 TNC(M) F1PTM S6-SA2B 370MHz IF to FOTS Cable Lengths
(1421G)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD BLK HELIAX ETS1-50T 8412 8

Date Printed: 3/29/07 Page 2 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67246 S 1007-A9J11 SMA(M) 225532-3 1007-A1J24 TNC(BH) 225557-6 S1-SSA1A 370MHz IF to RACK I/O Cable Lengths
(W67270)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD INTRA-RACK BLK COAX RG-400 8412 6.3

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67247 S 1008-A9J11 SMA(M) 225532-3 1008-A1J24 TNC(BH) 225557-6 S1-SSA1B 370MHz IF to RACK I/O Cable Lengths
(W67271)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD INTRA-RACK BLK COAX RG-400 8412 6.3

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67248 S 1009-A9J11 SMA(M) 225532-3 1009-A1J24 TNC(BH) 225557-6 S1-SSA2A 370MHz IF to RACK I/O Cable Lengths
(W67272)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD INTRA-RACK BLK COAX RG-400 8412 6.3

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67249 S 1010-A9J11 SMA(M) 225532-3 1010-A1J24 TNC(BH) 225557-6 S1-SSA2B 370MHz IF to RACK I/O Cable Lengths
(W67273)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD INTRA-RACK BLK COAX RG-400 8412 6.3

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67250 S 1207-A9J11 SMA(M) 225532-3 1207-A1J24 TNC(BH) 225557-6 S2-SSA1A 370MHz IF to RACK I/O Cable Lengths
(W67274)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD INTRA-RACK BLK COAX RG-400 8412 6.3

Date Printed: 3/29/07 Page 3 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67251 S 1208-A9J11 SMA(M) 225532-3 1208-A1J24 TNC(BH) 225557-6 S2-SSA1B 370MHz IF to RACK I/O Cable Lengths
(W67275)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD INTRA-RACK BLK COAX RG-400 8412 6.3

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67252 S 1209-A9J11 SMA(M) 225532-3 1209-A1J24 TNC(BH) 225557-6 S2-SSA2A 370MHz IF to RACK I/O Cable Lengths
(W67276)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD INTRA-RACK BLK COAX RG-400 8412 6.3

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67253 S 1210-A9J11 SMA(M) 225532-3 1210-A1J24 TNC(BH) 225557-6 S2-SSA2B 370MHz IF to RACK I/O Cable Lengths
(W67277)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD INTRA-RACK BLK COAX RG-400 8412 6.3

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67254 S 1407-A9J11 SMA(M) 225532-3 1407-A1J24 TNC(BH) 225557-6 S3-SSA1A 370MHz IF to RACK I/O Cable Lengths
(W67278)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD INTRA-RACK BLK COAX RG-400 8412 6.3

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67255 S 1408-A9J11 SMA(M) 225532-3 1408-A1J24 TNC(BH) 225557-6 S3-SSA1B 370MHz IF to RACK I/O Cable Lengths
(W67279)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD INTRA-RACK BLK COAX RG-400 8412 6.3

Date Printed: 3/29/07 Page 4 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67256 S 1409-A9J11 SMA(M) 225532-3 1409-A1J24 TNC(BH) 225557-6 S3-SSA2A 370MHz IF to RACK I/O Cable Lengths
(W67280)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD INTRA-RACK BLK COAX RG-400 8412 6.3

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67257 S 1410-A9J11 SMA(M) 225532-3 1410-A1J24 TNC(BH) 225557-6 S3-SSA2B 370MHz IF to RACK I/O Cable Lengths
(W67281)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD INTRA-RACK BLK COAX RG-400 8412 6.3

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67258 W 1007-A9J11 SMA(M) 225532-3 1007-A1J24 TNC(BH) 225557-6 S4-SSA1A 370MHz IF to RACK I/O Cable Lengths
(W67282)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD INTRA-RACK BLK COAX RG-400 8412 6.3

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67259 W 1008-A9J11 SMA(M) 225532-3 1008-A1J24 TNC(BH) 225557-6 S4-SSA1B 370MHz IF to RACK I/O Cable Lengths
(W67283)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD INTRA-RACK BLK COAX RG-400 8412 6.3

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67260 W 1009-A9J11 SMA(M) 225532-3 1009-A1J24 TNC(BH) 225557-6 S4-SSA2A 370MHz IF to RACK I/O Cable Lengths
(W67284)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD INTRA-RACK BLK COAX RG-400 8412 6.3

Date Printed: 3/29/07 Page 5 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67261 W 1010-A9J11 SMA(M) 225532-3 1010-A1J24 TNC(BH) 225557-6 S4-SSA2B 370MHz IF to RACK I/O Cable Lengths
(W67285)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD INTRA-RACK BLK COAX RG-400 8412 6.3

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67262 W 1207-A9J11 SMA(M) 225532-3 1207-A1J24 TNC(BH) 225557-6 S5-SSA1A 370MHz IF to RACK I/O Cable Lengths
(W67286)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD INTRA-RACK BLK COAX RG-400 8412 6.3

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67263 W 1208-A9J11 SMA(M) 225532-3 1208-A1J24 TNC(BH) 225557-6 S5-SSA1B 370MHz IF to RACK I/O Cable Lengths
(W67287)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD INTRA-RACK BLK COAX RG-400 8412 6.3

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67264 W 1209-A9J11 SMA(M) 225532-3 1209-A1J24 TNC(BH) 225557-6 S5-SSA2A 370MHz IF to RACK I/O Cable Lengths
(W67288)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD INTRA-RACK BLK COAX RG-400 8412 6.3

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67265 W 1210-A9J11 SMA(M) 225532-3 1210-A1J24 TNC(BH) 225557-6 S5-SSA2B 370MHz IF to RACK I/O Cable Lengths
(W67289)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD INTRA-RACK BLK COAX RG-400 8412 6.3

Date Printed: 3/29/07 Page 6 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67266 G 1407-A9J11 SMA(M) 225532-3 1407-A1J24 TNC(BH) 225557-6 S6-SSA1A 370MHz IF to RACK I/O Cable Lengths
(W67290)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD INTRA-RACK BLK COAX RG-400 8412 6.3

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67267 G 1408-A9J11 SMA(M) 225532-3 1408-A1J24 TNC(BH) 225557-6 S6-SSA1B 370MHz IF to RACK I/O Cable Lengths
(W67291)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD INTRA-RACK BLK COAX RG-400 8412 6.3

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67268 G 1409-A9J11 SMA(M) 225532-3 1409-A1J24 TNC(BH) 225557-6 S6-SSA2A 370MHz IF to RACK I/O Cable Lengths
(W67292)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD INTRA-RACK BLK COAX RG-400 8412 6.3

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67269 G 1410-A9J11 SMA(M) 225532-3 1410-A1J24 TNC(BH) 225557-6 S6-SSA2B 370MHz IF to RACK I/O Cable Lengths
(W67293)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD INTRA-RACK BLK COAX RG-400 8412 6.3

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67270 S 1007-A1J24 N(M) L4PNM-RC M/T W67442 N(M) L4PNM-RC S1-SSA1A 370MHz IF to FOTS Cable Lengths
(W67246) (7709S)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD RACK I/O TO FOTS BLK HELIAX HL4RP-50 1/2” 8412 100

Date Printed: 3/29/07 Page 7 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67271 S 1008-A1J24 N(M) L4PNM-RC M/T W67443 N(M) L4PNM-RC S1-SSA1B 370MHz IF to FOTS Cable Lengths
(W67247) (7709S)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD RACK I/O TO FOTS BLK HELIAX HL4RP-50 1/2” 8412 100

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67272 S 1009-A1J24 N(M) L4PNM-RC M/T W67444 N(M) L4PNM-RC S1-SSA2A 370MHz IF to FOTS Cable Lengths
(W67248) (7709S)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD RACK I/O TO FOTS BLK HELIAX HL4RP-50 1/2” 8412 100

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67273 S 1010-A1J24 N(M) L4PNM-RC M/T W67445 N(M) L4PNM-RC S1-SSA2B 370MHz IF to FOTS Cable Lengths
(W67249) (7709S)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD RACK I/O TO FOTS BLK HELIAX HL4RP-50 1/2” 8412 100

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67274 S 1207-A1J24 N(M) L4PNM-RC M/T W67446 N(M) L4PNM-RC S2-SSA1A 370MHz IF to FOTS Cable Lengths
(W67250) (7709S)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD RACK I/O TO FOTS BLK HELIAX HL4RP-50 1/2” 8412 100

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67275 S 1208-A1J24 N(M) L4PNM-RC M/T W67447 N(M) L4PNM-RC S2-SSA1B 370MHz IF to FOTS Cable Lengths
(W67251) (7709S)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD RACK I/O TO FOTS BLK HELIAX HL4RP-50 1/2” 8412 100

Date Printed: 3/29/07 Page 8 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67276 S 1209-A1J24 N(M) L4PNM-RC M/T W67448 N(M) L4PNM-RC S2-SSA2A 370MHz IF to FOTS Cable Lengths
(W67252) (7709S)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD RACK I/O TO FOTS BLK HELIAX HL4RP-50 1/2” 8412 100

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67277 S 1210-A1J24 N(M) L4PNM-RC M/T W67449 N(M) L4PNM-RC S2-SSA2B 370MHz IF to FOTS Cable Lengths
(W67253) (7709S)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD RACK I/O TO FOTS BLK HELIAX HL4RP-50 1/2” 8412 100

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67278 S 1407-A1J24 N(M) L4PNM-RC M/T W67450 N(M) L4PNM-RC S3-SSA1A 370MHz IF to FOTS Cable Lengths
(W67254) (7709S)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD RACK I/O TO FOTS BLK HELIAX HL4RP-50 1/2” 8412 100

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67279 S 1408-A1J24 N(M) L4PNM-RC M/T W67451 N(M) L4PNM-RC S3-SSA1B 370MHz IF to FOTS Cable Lengths
(W67255) (7709S)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD RACK I/O TO FOTS BLK HELIAX HL4RP-50 1/2” 8412 100

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67280 S 1409-A1J24 N(M) L4PNM-RC M/T W67452 N(M) L4PNM-RC S3-SSA2A 370MHz IF to FOTS Cable Lengths
(W67256) (7709S)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD RACK I/O TO FOTS BLK HELIAX HL4RP-50 1/2” 8412 100

Date Printed: 3/29/07 Page 9 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67281 S 1410-A1J24 N(M) L4PNM-RC M/T W67453 N(M) L4PNM-RC S3-SSA2B 370MHz IF to FOTS Cable Lengths
(W67257) (7709S)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD RACK I/O TO FOTS BLK HELIAX HL4RP-50 1/2” 8412 100

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67282 W 1007-A1J24 N(M) L4PNM-RC M/T W67454 N(M) L4PNM-RC S4-SSA1A 370MHz IF to PP Cable Lengths
(W67258) (7213W)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD RACK I/O TO PP BLK HELIAX HL4RP-50 1/2” 8412 90

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67283 W 1008-A1J24 N(M) L4PNM-RC M/T W67455 N(M) L4PNM-RC S4-SSA1B 370MHz IF to PP Cable Lengths
(W67259) (7213W)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD RACK I/O TO PP BLK HELIAX HL4RP-50 1/2” 8412 90

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67284 W 1009-A1J24 N(M) L4PNM-RC M/T W65447 N(M) L4PNM-RC S4-SSA2A 370MHz IF to PP Cable Lengths
(W67260) (7213W)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD RACK I/O TO PP BLK HELIAX HL4RP-50 1/2” 8412 90

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67285 W 1010-A1J24 N(M) L4PNM-RC M/T W65448 N(M) L4PNM-RC S4-SSA2B 370MHz IF to PP Cable Lengths
(W67261) (7213W)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD RACK I/O TO PP BLK HELIAX HL4RP-50 1/2” 8412 90

Date Printed: 3/29/07 Page 10 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67286 W 1207-A1J24 N(M) L4PNM-RC M/T W65449 N(M) L4PNM-RC S5-SSA1A 370MHz IF to PP Cable Lengths
(W67262) (7213W)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD RACK I/O TO PP BLK HELIAX HL4RP-50 1/2” 8412 90

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67287 W 1208-A1J24 N(M) L4PNM-RC M/T W65450 N(M) L4PNM-RC S5-SSA1B 370MHz IF to PP Cable Lengths
(W67263) (7213W)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD RACK I/O TO PP BLK HELIAX HL4RP-50 1/2” 8412 90

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67288 W 1209-A1J24 N(M) L4PNM-RC M/T W65451 N(M) L4PNM-RC S5-SSA2A 370MHz IF to PP Cable Lengths
(W67264) (7213W)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD RACK I/O TO PP BLK HELIAX HL4RP-50 1/2” 8412 90

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67289 W 1210-A1J24 N(M) L4PNM-RC M/T W65452 N(M) L4PNM-RC S5-SSA2B 370MHz IF to PP Cable Lengths
(W67265) (7213W)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD RACK I/O TO PP BLK HELIAX HL4RP-50 1/2” 8412 90

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67290 G 1407-A1J24 N(M) L4PNM-RC M/T W65453 N(M) L4PNM-RC S6-SSA1A 370MHz IF to PP Cable Lengths
(W67266) (1421G)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD RACK I/O TO PP BLK HELIAX HL4RP-50 1/2” 8412 65

Date Printed: 3/29/07 Page 11 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67291 G 1408-A1J24 N(M) L4PNM-RC M/T W65454 N(M) L4PNM-RC S6-SSA1B 370MHz IF to PP Cable Lengths
(W67267) (1421G)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD RACK I/O TO PP BLK HELIAX HL4RP-50 1/2” 8412 65

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67292 G 1409-A1J24 N(M) L4PNM-RC M/T W65455 N(M) L4PNM-RC S6-SSA2A 370MHz IF to PP Cable Lengths
(W67268) (1421G)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD RACK I/O TO PP BLK HELIAX HL4RP-50 1/2” 8412 65

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67293 G 1410-A1J24 N(M) L4PNM-RC M/T W65456 N(M) L4PNM-RC S6-SSA2B 370MHz IF to PP Cable Lengths
(W67269) (1421G)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD RACK I/O TO PP BLK HELIAX HL4RP-50 1/2” 8412 65

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67294 S 7709-A2CH22-OUT FC/APC(SM) 7709-A8CH22 FC/APC(SM) FOTS1-CH22-FIBER MUX to Cable Lengths
WSGT
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD S1-SA1A 370MHz IF BLK FIBER AX01-030S-SLS-90 8412 3
0-OFNP

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67295 S 7709-A2CH23-OUT FC/APC(SM) 7709-A8CH23 FC/APC(SM) FOTS1-CH23-FIBER MUX to Cable Lengths
WSGT
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD S1-SA1B 370MHz IF BLK FIBER AX01-030S-SLS-90 8412 3
0-OFNP

Date Printed: 3/29/07 Page 12 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67296 S 7709-A2CH24-OUT FC/APC(SM) 7709-A8CH24 FC/APC(SM) FOTS1-CH24-FIBER MUX to Cable Lengths
WSGT
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD S1-SA2A 370MHz IF BLK FIBER AX01-030S-SLS-90 8412 3
0-OFNP

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67297 S 7709-A2CH25-OUT FC/APC(SM) 7709-A8CH25 FC/APC(SM) FOTS1-CH25-FIBER MUX to Cable Lengths
WSGT
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD S1-SA2B 370MHz IF BLK FIBER AX01-030S-SLS-90 8412 3
0-OFNP

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67298 S 7709-A2CH26-OUT FC/APC(SM) 7709-A8CH26 FC/APC(SM) FOTS1-CH26-FIBER MUX to Cable Lengths
WSGT
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD S2-SA1A 370MHz IF BLK FIBER AX01-030S-SLS-90 8412 3
0-OFNP

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67299 S 7709-A2CH27-OUT FC/APC(SM) 7709-A8CH27 FC/APC(SM) FOTS1-CH27-FIBER MUX to Cable Lengths
WSGT
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD S2-SA1B 370MHz IF BLK FIBER AX01-030S-SLS-90 8412 3
0-OFNP

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67300 S 7709-A2CH28-OUT FC/APC(SM) 7709-A8CH28 FC/APC(SM) FOTS1-CH28-FIBER MUX to Cable Lengths
WSGT
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD S2-SA2A 370MHz IF BLK FIBER AX01-030S-SLS-90 8412 3
0-OFNP

Date Printed: 3/29/07 Page 13 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67301 S 7709-A2CH29-OUT FC/APC(SM) 7709-A8CH29 FC/APC(SM) FOTS1-CH29-FIBER MUX to Cable Lengths
WSGT
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD S2-SA2B 370MHz IF BLK FIBER AX01-030S-SLS-90 8412 3
0-OFNP

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67302 S 7709-A5CH30-OUT FC/APC(SM) 7709-A8CH30 FC/APC(SM) FOTS2-CH30-FIBER MUX to Cable Lengths
WSGT
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD S3-SA1A 370MHz IF BLK FIBER AX01-030S-SLS-90 8412 3
0-OFNP

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67303 S 7709-A5CH31-OUT FC/APC(SM) 7709-A8CH31 FC/APC(SM) FOTS2-CH31-FIBER MUX to Cable Lengths
WSGT
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD S3-SA1B 370MHz IF BLK FIBER AX01-030S-SLS-90 8412 3
0-OFNP

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67304 S 7709-A5CH32-OUT FC/APC(SM) 7709-A8CH32 FC/APC(SM) FOTS2-CH32-FIBER MUX to Cable Lengths
WSGT
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD S3-SA2A 370MHz IF BLK FIBER AX01-030S-SLS-90 8412 3
0-OFNP

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67305 S 7709-A5CH33-OUT FC/APC(SM) 7709-A8CH33 FC/APC(SM) FOTS2-CH33-FIBER MUX to Cable Lengths
WSGT
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD S3-SA2B 370MHz IF BLK FIBER AX01-030S-SLS-90 8412 3
0-OFNP

Date Printed: 3/29/07 Page 14 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67306 S 7709-A5CH34-OUT FC/APC(SM) 7709-A8CH34 FC/APC(SM) FOTS2-CH34-FIBER MUX to Cable Lengths
WSGT-SPARE
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD SPARE BLK FIBER AX01-030S-SLS-90 8412 3
0-OFNP

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67307 S 7709-A5CH35-OUT FC/APC(SM) 7709-A8CH35 FC/APC(SM) FOTS2-CH35-FIBER MUX to Cable Lengths
WSGT-SPARE
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD SPARE BLK FIBER AX01-030S-SLS-90 8412 3
0-OFNP

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67308 S 7709-A8-COM FC/APC(SM) 7101-115H2J1 ST(SM) 95-200-51 DWDM FIBER MUX to WSGT via Cable Lengths
IFL
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD IF FIBER MUX OUT BLK FIBER AX01-030S-SLS-90 8412 120
0-OFNP

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67309 W 7101-115H2J1 ST(SM) 95-200-51 7213-A1-IN FC/APC(SM) From STGT via IFL to FIBER AMP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD IF FIBER AMP IN BLK FIBER AX01-030S-SLS-90 8412 80
0-OFNP

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67310 W 7213-A1-OUT FC/APC(SM) 7213-A2-COM FC/APC(SM) FIBER AMP to FIBER DEMUX Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK FIBER AX01-030S-SLS-90 8412 3
0-OFNP

Date Printed: 3/29/07 Page 15 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67311 W 7213-A2CH22 FC/APC(SM) 7213-A3CH22-IN FC/APC(SM) FIBER DEMUX CH22 to FOTS Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S1-SA1A 370MHz IF BLK FIBER AX01-030S-SLS-90 8412 3
0-OFNP

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67312 W 7213-A2CH23 FC/APC(SM) 7213-A3CH23-IN FC/APC(SM) FIBER DEMUX CH23 to FOTS Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S1-SA1B 370MHz IF BLK FIBER AX01-030S-SLS-90 8412 3
0-OFNP

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67313 W 7213-A2CH24 FC/APC(SM) 7213-A3CH24-IN FC/APC(SM) FIBER DEMUX CH24 to FOTS Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S1-SA2A 370MHz IF BLK FIBER AX01-030S-SLS-90 8412 3
0-OFNP

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67314 W 7213-A2CH25 FC/APC(SM) 7213-A3CH25-IN FC/APC(SM) FIBER DEMUX CH25 to FOTS Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S1-SA2B 370MHz IF BLK FIBER AX01-030S-SLS-90 8412 3
0-OFNP

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67315 W 7213-A2CH26 FC/APC(SM) 7213-A3CH26-IN FC/APC(SM) FIBER DEMUX CH26 to FOTS Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S2-SA1A 370MHz IF BLK FIBER AX01-030S-SLS-90 8412 3
0-OFNP

Date Printed: 3/29/07 Page 16 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67316 W 7213-A2CH27 FC/APC(SM) 7213-A3CH27-IN FC/APC(SM) FIBER DEMUX CH27 to FOTS Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S2-SA1B 370MHz IF BLK FIBER AX01-030S-SLS-90 8412 3
0-OFNP

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67317 W 7213-A2CH28 FC/APC(SM) 7213-A3CH28-IN FC/APC(SM) FIBER DEMUX CH28 to FOTS Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S2-SA2A 370MHz IF BLK FIBER AX01-030S-SLS-90 8412 3
0-OFNP

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67318 W 7213-A2CH29 FC/APC(SM) 7213-A3CH29-IN FC/APC(SM) FIBER DEMUX CH29 to FOTS Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S2-SA2B 370MHz IF BLK FIBER AX01-030S-SLS-90 8412 3
0-OFNP

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67319 W 7213-A2CH30 FC/APC(SM) 7213-A6CH30-IN FC/APC(SM) FIBER DEMUX CH30 to FOTS Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S3-SA1A 370MHz IF BLK FIBER AX01-030S-SLS-90 8412 3
0-OFNP

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67320 W 7213-A2CH31 FC/APC(SM) 7213-A6CH31-IN FC/APC(SM) FIBER DEMUX CH31 to FOTS Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S3-SA1B 370MHz IF BLK FIBER AX01-030S-SLS-90 8412 3
0-OFNP

Date Printed: 3/29/07 Page 17 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67321 W 7213-A2CH32 FC/APC(SM) 7213-A6CH32-IN FC/APC(SM) FIBER DEMUX CH32 to FOTS Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S3-SA2A 370MHz IF BLK FIBER AX01-030S-SLS-90 8412 3
0-OFNP

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67322 W 7213-A2CH33 FC/APC(SM) 7213-A6CH33-IN FC/APC(SM) FIBER DEMUX CH33 to FOTS Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S3-SA2B 370MHz IF BLK FIBER AX01-030S-SLS-90 8412 3
0-OFNP

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67323 W 7213-A2CH34 FC/APC(SM) 7213-A6CH34-IN FC/APC(SM) FIBER DEMUX CH34 to FOTS Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD SPARE BLK FIBER AX01-030S-SLS-90 8412 3
0-OFNP

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67324 W 7213-A2CH35 FC/APC(SM) 7213-A6CH35-IN FC/APC(SM) FIBER DEMUX CH35 to FOTS Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD SPARE BLK FIBER AX01-030S-SLS-90 8412 3
0-OFNP

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67325 W 7213-A3CH22-OUT SMA(M) 225532-3 7213-A20J1 TNC(M) 225345-6 FOTS CH22 to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S1-SA1A 370MHz IF BLK COAX RG-400 8412 8

Date Printed: 3/29/07 Page 18 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67326 W 7213-A3CH23-OUT SMA(M) 225532-3 7213-A20J2 TNC(M) 225345-6 FOTS CH23 to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S1-SA1B 370MHz IF BLK COAX RG-400 8412 8

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67327 W 7213-A3CH24-OUT SMA(M) 225532-3 7213-A20J3 TNC(M) 225345-6 FOTS CH24 to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S1-SA2A 370MHz IF BLK COAX RG-400 8412 8

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67328 W 7213-A3CH25-OUT SMA(M) 225532-3 7213-A20J4 TNC(M) 225345-6 FOTS CH25 to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S1-SA2B 370MHz IF BLK COAX RG-400 8412 8

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67329 W 7213-A3CH26-OUT SMA(M) 225532-3 7213-A20J5 TNC(M) 225345-6 FOTS CH26 to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S2-SA1A 370MHz IF BLK COAX RG-400 8412 8

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67330 W 7213-A3CH27-OUT SMA(M) 225532-3 7213-A20J6 TNC(M) 225345-6 FOTS CH27 to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S2-SA1B 370MHz IF BLK COAX RG-400 8412 8

Date Printed: 3/29/07 Page 19 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67331 W 7213-A3CH28-OUT SMA(M) 225532-3 7213-A20J7 TNC(M) 225345-6 FOTS CH28 to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S2-SA2A 370MHz IF BLK COAX RG-400 8412 8

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67332 W 7213-A3CH29-OUT SMA(M) 225532-3 7213-A20J8 TNC(M) 225345-6 FOTS CH29 to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S2-SA2B 370MHz IF BLK COAX RG-400 8412 8

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67333 W 7213-A6CH30-OUT SMA(M) 225532-3 7213-A20J9 TNC(M) 225345-6 FOTS CH30 to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S3-SA1A 370MHz IF BLK COAX RG-400 8412 8

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67334 W 7213-A6CH31-OUT SMA(M) 225532-3 7213-A20J10 TNC(M) 225345-6 FOTS CH31 to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S3-SA1B 370MHz IF BLK COAX RG-400 8412 8

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67335 W 7213-A6CH32-OUT SMA(M) 225532-3 7213-A20J11 TNC(M) 225345-6 FOTS CH32 to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S3-SA2A 370MHz IF BLK COAX RG-400 8412 8

Date Printed: 3/29/07 Page 20 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67336 W 7213-A6CH33-OUT SMA(M) 225532-3 7213-A20J12 TNC(M) 225345-6 FOTS CH33 to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S3-SA2B 370MHz IF BLK COAX RG-400 8412 8

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67337 W 7213-A20J17 TNC(M) 225345-6 7213-A10J1 SMA(M) 225532-3 PP to IN1 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S1-SA1A 370MHz IF BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67338 W 7213-A20J18 TNC(M) 225345-6 7213-A10J2 SMA(M) 225532-3 PP to IN2 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S1-SA1B 370MHz IF BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67339 W 7213-A20J19 TNC(M) 225345-6 7213-A10J3 SMA(M) 225532-3 PP to IN3 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S1-SA2A 370MHz IF BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67340 W 7213-A20J20 TNC(M) 225345-6 7213-A10J4 SMA(M) 225532-3 PP to IN4 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S1-SA2B 370MHz IF BLK COAX RG-400 8412 7

Date Printed: 3/29/07 Page 21 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67341 W 7213-A20J21 TNC(M) 225345-6 7213-A10J5 SMA(M) 225532-3 PP to IN5 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S2-SA1A 370MHz IF BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67342 W 7213-A20J22 TNC(M) 225345-6 7213-A10J6 SMA(M) 225532-3 PP to IN6 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S2-SA1B 370MHz IF BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67343 W 7213-A20J23 TNC(M) 225345-6 7213-A10J7 SMA(M) 225532-3 PP to IN7 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S2-SA2A 370MHz IF BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67344 W 7213-A20J24 TNC(M) 225345-6 7213-A10J8 SMA(M) 225532-3 PP to IN8 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S2-SA2B 370MHz IF BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67345 W 7213-A20J25 TNC(M) 225345-6 7213-A10J9 SMA(M) 225532-3 PP to IN9 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S3-SA1A 370MHz IF BLK COAX RG-400 8412 7

Date Printed: 3/29/07 Page 22 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67346 W 7213-A20J26 TNC(M) 225345-6 7213-A10J10 SMA(M) 225532-3 PP to IN10 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S3-SA1B 370MHz IF BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67347 W 7213-A20J27 TNC(M) 225345-6 7213-A10J11 SMA(M) 225532-3 PP to IN11 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S3-SA2A 370MHz IF BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67348 W 7213-A20J28 TNC(M) 225345-6 7213-A10J12 SMA(M) 225532-3 PP to IN12 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S3-SA2B 370MHz IF BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67349 W 7213-A20J29 TNC(M) 225345-6 7213-A10J13 SMA(M) 225532-3 PP to IN13 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S4-SA1A 370MHz IF BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67350 W 7213-A20J30 TNC(M) 225345-6 7213-A10J14 SMA(M) 225532-3 PP to IN14 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S4-SA1B 370MHz IF BLK COAX RG-400 8412 7

Date Printed: 3/29/07 Page 23 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67351 W 7213-A20J31 TNC(M) 225345-6 7213-A10J15 SMA(M) 225532-3 PP to IN15 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S4-SA2A 370MHz IF BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67352 W 7213-A20J32 TNC(M) 225345-6 7213-A10J16 SMA(M) 225532-3 PP to IN16 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S4-SA2B 370MHz IF BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67353 W 7213-A22J17 TNC(M) 225345-6 7213-A10J17 SMA(M) 225532-3 PP to IN17 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S5-SA1A 370MHz IF BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67354 W 7213-A22J18 TNC(M) 225345-6 7213-A10J18 SMA(M) 225532-3 PP to IN18 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S5-SA1B 370MHz IF BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67355 W 7213-A22J19 TNC(M) 225345-6 7213-A10J19 SMA(M) 225532-3 PP to IN19 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S5-SA2A 370MHz IF BLK COAX RG-400 8412 7

Date Printed: 3/29/07 Page 24 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67356 W 7213-A22J20 TNC(M) 225345-6 7213-A10J20 SMA(M) 225532-3 PP to IN20 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S5-SA2B 370MHz IF BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67357 W 7213-A22J21 TNC(M) 225345-6 7213-A10J21 SMA(M) 225532-3 PP to IN21 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD (NOT USED) BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67358 W 7213-A22J22 TNC(M) 225345-6 7213-A10J22 SMA(M) 225532-3 PP to IN22 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD (NOT USED) BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67359 W 7213-A22J23 TNC(M) 225345-6 7213-A10J23 SMA(M) 225532-3 PP to IN23 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD (NOT USED) BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67360 W 7213-A22J24 TNC(M) 225345-6 7213-A10J24 SMA(M) 225532-3 PP to IN24 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD (NOT USED) BLK COAX RG-400 8412 7

Date Printed: 3/29/07 Page 25 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67361 W 7213-A22J25 TNC(M) 225345-6 7213-A10J25 SMA(M) 225532-3 PP to IN25 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD (NOT USED) BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67362 W 7213-A22J26 TNC(M) 225345-6 7213-A10J26 SMA(M) 225532-3 PP to IN26 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD (NOT USED) BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67363 W 7213-A22J27 TNC(M) 225345-6 7213-A10J27 SMA(M) 225532-3 PP to IN27 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD (NOT USED) BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67364 W 7213-A22J28 TNC(M) 225345-6 7213-A10J28 SMA(M) 225532-3 PP to IN28 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD (NOT USED) BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67365 W 7213-A22J29 TNC(M) 225345-6 7213-A10J29 SMA(M) 225532-3 PP to IN29 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD (NOT USED) BLK COAX RG-400 8412 7

Date Printed: 3/29/07 Page 26 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67366 W 7213-A22J30 TNC(M) 225345-6 7213-A10J30 SMA(M) 225532-3 PP to IN30 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD (NOT USED) BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67367 W 7213-A22J31 TNC(M) 225345-6 7213-A10J31 SMA(M) 225532-3 PP to IN31 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD (NOT USED) BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67368 W 7213-A22J32 TNC(M) 225345-6 7213-A10J32 SMA(M) 225532-3 PP to IN32 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD (NOT USED) BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67369 W 7213-A10J33 SMA(M) 225532-3 7213-A24J1 TNC(M) 225345-6 OUT1 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67370 W 7213-A10J34 SMA(M) 225532-3 7213-A24J2 TNC(M) 225345-6 OUT2 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

Date Printed: 3/29/07 Page 27 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67371 W 7213-A10J35 SMA(M) 225532-3 7213-A24J3 TNC(M) 225345-6 OUT3 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67372 W 7213-A10J36 SMA(M) 225532-3 7213-A24J4 TNC(M) 225345-6 OUT4 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67373 W 7213-A10J37 SMA(M) 225532-3 7213-A24J5 TNC(M) 225345-6 OUT5 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67374 W 7213-A10J38 SMA(M) 225532-3 7213-A24J6 TNC(M) 225345-6 OUT6 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67375 W 7213-A10J39 SMA(M) 225532-3 7213-A24J7 TNC(M) 225345-6 OUT7 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

Date Printed: 3/29/07 Page 28 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67376 W 7213-A10J40 SMA(M) 225532-3 7213-A24J8 TNC(M) 225345-6 OUT8 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67377 W 7213-A10J41 SMA(M) 225532-3 7213-A24J9 TNC(M) 225345-6 OUT9 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67378 W 7213-A10J42 SMA(M) 225532-3 7213-A24J10 TNC(M) 225345-6 OUT10 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67379 W 7213-A10J43 SMA(M) 225532-3 7213-A24J11 TNC(M) 225345-6 OUT11 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67380 W 7213-A10J44 SMA(M) 225532-3 7213-A24J12 TNC(M) 225345-6 OUT12 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

Date Printed: 3/29/07 Page 29 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67381 W 7213-A10J45 SMA(M) 225532-3 7213-A24J13 TNC(M) 225345-6 OUT13 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67382 W 7213-A10J46 SMA(M) 225532-3 7213-A24J14 TNC(M) 225345-6 OUT14 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67383 W 7213-A10J47 SMA(M) 225532-3 7213-A24J15 TNC(M) 225345-6 OUT15 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67384 W 7213-A10J48 SMA(M) 225532-3 7213-A24J16 TNC(M) 225345-6 OUT16 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67385 W 7213-A10J49 SMA(M) 225532-3 7213-A26J1 TNC(M) 225345-6 OUT17 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

Date Printed: 3/29/07 Page 30 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67386 W 7213-A10J50 SMA(M) 225532-3 7213-A26J2 TNC(M) 225345-6 OUT18 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67387 W 7213-A10J51 SMA(M) 225532-3 7213-A26J3 TNC(M) 225345-6 OUT19 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67388 W 7213-A10J52 SMA(M) 225532-3 7213-A26J4 TNC(M) 225345-6 OUT20 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67389 W 7213-A10J53 SMA(M) 225532-3 7213-A26J5 TNC(M) 225345-6 OUT21 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67390 W 7213-A10J54 SMA(M) 225532-3 7213-A26J6 TNC(M) 225345-6 OUT22 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

Date Printed: 3/29/07 Page 31 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67391 W 7213-A10J55 SMA(M) 225532-3 7213-A26J7 TNC(M) 225345-6 OUT23 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67392 W 7213-A10J56 SMA(M) 225532-3 7213-A26J8 TNC(M) 225345-6 OUT24 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67393 W 7213-A10J57 SMA(M) 225532-3 7213-A26J9 TNC(M) 225345-6 OUT25 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67394 W 7213-A10J58 SMA(M) 225532-3 7213-A26J10 TNC(M) 225345-6 OUT26 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67395 W 7213-A10J59 SMA(M) 225532-3 7213-A26J11 TNC(M) 225345-6 OUT27 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

Date Printed: 3/29/07 Page 32 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67396 W 7213-A10J60 SMA(M) 225532-3 7213-A26J12 TNC(M) 225345-6 OUT28 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67397 W 7213-A10J61 SMA(M) 225532-3 7213-A26J13 TNC(M) 225345-6 OUT29 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67398 W 7213-A10J62 SMA(M) 225532-3 7213-A26J14 TNC(M) 225345-6 OUT30 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67399 W 7213-A10J63 SMA(M) 225532-3 7213-A26J15 TNC(M) 225345-6 OUT31 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67400 W 7213-A10J64 SMA(M) 225532-3 7213-A26J16 TNC(M) 225345-6 OUT32 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 7

Date Printed: 3/29/07 Page 33 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67401 G 1421-A11J17 TNC(M) 225345-6 1421-A13J1 SMA(M) 225532-3 PP to IN1 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S6-SA1A 370MHz IF BLK COAX RG-400 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67402 G 1421-A11J18 TNC(M) 225345-6 1421-A13J2 SMA(M) 225532-3 PP to IN2 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S6-SA1B 370MHz IF BLK COAX RG-400 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67403 G 1421-A11J19 TNC(M) 225345-6 1421-A13J3 SMA(M) 225532-3 PP to IN3 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S6-SA2A 370MHz IF BLK COAX RG-400 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67404 G 1421-A11J20 TNC(M) 225345-6 1421-A13J4 SMA(M) 225532-3 PP to IN4 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD S6-SA2B 370MHz IF BLK COAX RG-400 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67405 G 1421-A11J21 TNC(M) 225345-6 1421-A13J5 SMA(M) 225532-3 PP to IN5 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD (NOT USED) BLK COAX RG-400 8412 6

Date Printed: 3/29/07 Page 34 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67406 G 1421-A11J22 TNC(M) 225345-6 1421-A13J6 SMA(M) 225532-3 PP to IN6 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD (NOT USED) BLK COAX RG-400 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67407 G 1421-A11J23 TNC(M) 225345-6 1421-A13J7 SMA(M) 225532-3 PP to IN7 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD (NOT USED) BLK COAX RG-400 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67408 G 1421-A11J24 TNC(M) 225345-6 1421-A13J8 SMA(M) 225532-3 PP to IN8 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD (NOT USED) BLK COAX RG-400 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67409 G 1421-A11J25 TNC(M) 225345-6 1421-A13J9 SMA(M) 225532-3 PP to IN9 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD (NOT USED) BLK COAX RG-400 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67410 G 1421-A11J26 TNC(M) 225345-6 1421-A13J10 SMA(M) 225532-3 PP to IN10 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD (NOT USED) BLK COAX RG-400 8412 6

Date Printed: 3/29/07 Page 35 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67411 G 1421-A11J27 TNC(M) 225345-6 1421-A13J11 SMA(M) 225532-3 PP to IN11 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD (NOT USED) BLK COAX RG-400 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67412 G 1421-A11J28 TNC(M) 225345-6 1421-A13J12 SMA(M) 225532-3 PP to IN12 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD (NOT USED) BLK COAX RG-400 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67413 G 1421-A11J29 TNC(M) 225345-6 1421-A13J13 SMA(M) 225532-3 PP to IN13 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD (NOT USED) BLK COAX RG-400 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67414 G 1421-A11J30 TNC(M) 225345-6 1421-A13J14 SMA(M) 225532-3 PP to IN14 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD (NOT USED) BLK COAX RG-400 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67415 G 1421-A11J31 TNC(M) 225345-6 1421-A13J15 SMA(M) 225532-3 PP to IN15 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD (NOT USED) BLK COAX RG-400 8412 6

Date Printed: 3/29/07 Page 36 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67416 G 1421-A11J32 TNC(M) 225345-6 1421-A13J16 SMA(M) 225532-3 PP to IN16 IF SWITCH Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD (NOT USED) BLK COAX RG-400 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67417 G 1421-A13J17 SMA(M) 225532-3 1421-A10J1 TNC(M) 225345-6 OUT1 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67418 G 1421-A13J18 SMA(M) 225532-3 1421-A10J2 TNC(M) 225345-6 OUT2 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67419 G 1421-A13J19 SMA(M) 225532-3 1421-A10J3 TNC(M) 225345-6 OUT3 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67420 G 1421-A13J20 SMA(M) 225532-3 1421-A10J4 TNC(M) 225345-6 OUT4 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 6

Date Printed: 3/29/07 Page 37 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67421 G 1421-A13J21 SMA(M) 225532-3 1421-A10J5 TNC(M) 225345-6 OUT5 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67422 G 1421-A13J22 SMA(M) 225532-3 1421-A10J6 TNC(M) 225345-6 OUT6 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67423 G 1421-A13J23 SMA(M) 225532-3 1421-A10J7 TNC(M) 225345-6 OUT7 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67424 G 1421-A13J24 SMA(M) 225532-3 1421-A10J8 TNC(M) 225345-6 OUT8 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67425 G 1421-A13J25 SMA(M) 225532-3 1421-A10J9 TNC(M) 225345-6 OUT9 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 6

Date Printed: 3/29/07 Page 38 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67426 G 1421-A13J26 SMA(M) 225532-3 1421-A10J10 TNC(M) 225345-6 OUT10 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67427 G 1421-A13J27 SMA(M) 225532-3 1421-A10J11 TNC(M) 225345-6 OUT11 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67428 G 1421-A13J28 SMA(M) 225532-3 1421-A10J12 TNC(M) 225345-6 OUT12 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67429 G 1421-A13J29 SMA(M) 225532-3 1421-A10J13 TNC(M) 225345-6 OUT13 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67430 G 1421-A13J30 SMA(M) 225532-3 1421-A10J14 TNC(M) 225345-6 OUT14 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 6

Date Printed: 3/29/07 Page 39 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67431 G 1421-A13J31 SMA(M) 225532-3 1421-A10J15 TNC(M) 225345-6 OUT15 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67432 G 1421-A13J32 SMA(M) 225532-3 1421-A10J16 TNC(M) 225345-6 OUT16 IF SWITCH to PP Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD BLK COAX RG-400 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67433 A S 7709-C1J2 CIRC-13 7104-A3CH9-RXD TRB PL75C-222 STATUS RX FOTS from SAR-IF Cable Lengths
MS27467T11-F35S SW
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD SAR-IF SW STATUS (WSGT) TO SW CONTROLLER (STGT) BLK M/W CXN2363 8412 120

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67433 B S 7709-C1J2 CIRC-13 7104-A3CH9-TXD TRB PL75C-222 CMD TX FOTS to SAR-IF SW Cable Lengths
MS27467T11-F35S
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD SW CONTROLLER CMD (STGT) TO SAR-IF SW (WSGT) BLK M/W CXN2363 8412 120

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67434 A S 7104-A3CH9RX(FO) ST(SM) 95-200-51 7101-A4-128J2J2 ST(SM) 95-200-51 STATUS RX from SAR-IF SW VIA Cable Lengths
IFL FOTS
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD SSAR-IF SW STATUS (WSGT) TO SW CONTROLLER (STGT) BLK FIBER AX01-030S-SLS-90 8412 30
-FIBER 0-OFNP

Date Printed: 3/29/07 Page 40 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67434 B S 7104-A3CH9TX(FO) ST(SM) 95-200-51 7101-A4-127J2J1 ST(SM) 95-200-51 CMD TX to SSAR-IF SW VIA IFL Cable Lengths
FOTS
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD SW CONTROLLER CMD TX (STGT) TO SAR-IF SW (WSGT) -FIBER BLK FIBER AX01-030S-SLS-90 8412 30
0-OFNP

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67435 A W 7104-A3CH9TX(FO) ST(SM) 95-200-51 7101-A2-128J2J2 ST(SM) 95-200-51 STATUS RX from SSAR-IF SW Cable Lengths
VIA IFL FOTS
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD SSAR-IF SW STATUS (WSGT) TO SW CONTROLLER (STGT) BLK FIBER AX01-030S-SLS-90 8412 30
-FIBER 0-OFNP

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67435 B W 7104-A3CH9RX(FO) ST(SM) 95-200-51 7101-A2-127J2J1 ST(SM) 95-200-51 CMD TX to SSAR-IF SW VIA IFL Cable Lengths
FOTS
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD SW CONTROLLER CMD TX (STGT) TO SSAR-IF SW (WSGT) BLK FIBER AX01-030S-SLS-90 8412 30
-FIBER 0-OFNP

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67436 A W 7213-A17J4 DE9S M24308/2-1 7104-A3CH9-RXD TRB PL75C-222 STATUS RX FOTS from SSAR-IF Cable Lengths
SW
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD SSAR-IF SW STATUS (WSGT) TO SW CONTROLLER (STGT) BLK M/W CXN2363 8412 90

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67436 B W 7213-A17J4 DE9S M24308/2-1 7104-A3CH9-TXD TRB PL75C-222 CMD TX FOTS to SSAR-IF SW Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD SW CONTROLLER CMD (STGT) TO SSAR-IF SW (WSGT) BLK M/W CXN2363 8412 90

Date Printed: 3/29/07 Page 41 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67437 W 7213-A17J3 CIRCULAR 7213-A10J67 CIRCULAR DC POWER TO SSAR-IF SW Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD VENDOR SUPPLIED BLK M/W 8412

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67438 W 7213-A17J5 DE9S 7213-A10J65 DE9S STATUS AND CONTROL SSAR-IF Cable Lengths
SW
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD VENDOR SUPPLIED BLK M/W 8412

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67439 G 1457-C1J6 CIRC-13 1421-A12J4 DE9S M24308/2-1 STATUS/CMD SSAR-IF SW Cable Lengths
MS27467T11-F35S
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD SSAR-IF SW STATUS/CMD TO WSGT CTFS SSC VIA GLISC BLK M/W CXN2363 8412 40

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67440 G 1421-A12J3 CIRCULAR 1421-A13J35 CIRCULAR DC POWER TO SSAR-IF SW Cable Lengths

Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT


ADD VENDOR SUPPLIED BLK M/W 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67441 G 1421-A12J5 DE9S 1421-A13J33 DE9S STATUS AND CONTROL SSAR-IF Cable Lengths
SW
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD VENDOR SUPPLIED BLK M/W 8412 5

Date Printed: 3/29/07 Page 42 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67442 S M/T W67270 N(F) F1PNF-BH 7709-A2CH22-IN SMA(M) 41EWS S1-SA1A 370MHz IF to FOTS Cable Lengths
(7709S)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD BLK HELIAX ETS1-50T 8412 10

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67443 S M/T W67271 N(F) F1PNF-BH 7709-A2CH23-IN SMA(M) 41EWS S1-SA1B 370MHz IF to FOTS Cable Lengths
(7709S)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD BLK HELIAX ETS1-50T 8412 10

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67444 S M/T W67272 N(F) F1PNF-BH 7709-A2CH24-IN SMA(M) 41EWS S1-SA2A 370MHz IF to FOTS Cable Lengths
(7709S)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD BLK HELIAX ETS1-50T 8412 10

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67445 S M/T W67273 N(F) F1PNF-BH 7709-A2CH25-IN SMA(M) 41EWS S1-SA2B 370MHz IF to FOTS Cable Lengths
(7709S)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD BLK HELIAX ETS1-50T 8412 10

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67446 S M/T W67274 N(F) F1PNF-BH 7709-A2CH26-IN SMA(M) 41EWS S2-SA1A 370MHz IF to FOTS Cable Lengths
(7709S)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD BLK HELIAX ETS1-50T 8412 10

Date Printed: 3/29/07 Page 43 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67447 S M/T W67275 N(F) F1PNF-BH 7709-A2CH27-IN SMA(M) 41EWS S2-SA1B 370MHz IF to FOTS Cable Lengths
(7709S)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD BLK HELIAX ETS1-50T 8412 10

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67448 S M/T W67276 N(F) F1PNF-BH 7709-A2CH28-IN SMA(M) 41EWS S2-SA2A 370MHz IF to FOTS Cable Lengths
(7709S)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD BLK HELIAX ETS1-50T 8412 10

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67449 S M/T W67277 N(F) F1PNF-BH 7709-A2CH29-IN SMA(M) 41EWS S2-SA2B 370MHz IF to FOTS Cable Lengths
(7709S)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD BLK HELIAX ETS1-50T 8412 10

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67450 S M/T W67278 N(F) F1PNF-BH 7709-A5CH30-IN SMA(M) 41EWS S3-SA1A 370MHz IF to FOTS Cable Lengths
(7709S)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD BLK HELIAX ETS1-50T 8412 10

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67451 S M/T W67279 N(F) F1PNF-BH 7709-A5CH31-IN SMA(M) 41EWS S3-SA1B 370MHz IF to FOTS Cable Lengths
(7709S)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD BLK HELIAX ETS1-50T 8412 10

Date Printed: 3/29/07 Page 44 Form Revision Date: 12/22/98


EC 8412CH1 CABLE UPGRADE CONTROL SHEET

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67452 S M/T W67280 N(F) F1PNF-BH 7709-A5CH32-IN SMA(M) 41EWS S3-SA2A 370MHz IF to FOTS Cable Lengths
(7709S)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD BLK HELIAX ETS1-50T 8412 10

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67453 S M/T W67281 N(F) F1PNF-BH 7709-A5CH33-IN SMA(M) 41EWS S3-SA2B 370MHz IF to FOTS Cable Lengths
(7709S)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD BLK HELIAX ETS1-50T 8412 10

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67454 W M/T W67282 N(F) F1PNF-BH 7213-A20J13 TNC(M) F1PTM S4-SA1A 370MHz IF to FOTS Cable Lengths
(7213W)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD BLK HELIAX ETS1-50T 8412 6

SITE
W# Su S W G From From Conn PN To To Conn PN Function
67455 W M/T W67283 N(F) F1PNF-BH 7213-A20J14 TNC(M) F1PTM S4-SA1B 370MHz IF to FOTS Cable Lengths
(7213W)
Change-Type Comments Class Type Cable PN EC # STGT WSGT GRGT
ADD BLK HELIAX ETS1-50T 8412 6

Date Printed: 3/29/07 Page 45 Form Revision Date: 12/22/98


WHITE SANDS COMPLEX

DRAFT

SYSTEM TEST DATA


RECORD
SSAR-IF
EC-8412CH1
S-Band Single Access Return Intermediate Frequency (SSAR-IF) Infrastructure
White Sands Complex (WSC) and Guam Remote Ground Terminal (GRGT)

Prepared by Mark Hibner


NASA WSC Engineering

March 2007
Table of Contents
1. TEST METHODOLGY.................................................................................................. 3
2. TEST EQUIPMENT....................................................................................................... 5
3. USS SSA/KSA IF SWITCH MODIFICATION LEVELS............................................. 6
4. PERFORMANCE CRITERIA ..................................................................................... 10
4.1 SSAR-IF Infrastructure Gain Flatness .................................................................. 10
4.2 SSAR-IF Infrastructure Gain Slope ...................................................................... 23
4.3 SSAR-IF Infrastructure 3 dB Bandwidth.............................................................. 27
4.4 SSAR-IF Infrastructure IF Frequency .................................................................. 40
4.5 SSAR-IF Infrastructure S-band to IF Processing/IF Output Level....................... 41
4.5.1 One-to-One Test........................................................................................ 42
4.5.2 One-to-Many Test..................................................................................... 42
4.6 SSAR-IF Infrastructure Spurious Outputs ............................................................ 45
4.7 SSAR-IF Infrastructure AM/PM........................................................................... 58
4.8 SSAR-IF Infrastructure Noise Figure ................................................................... 64
4.8.1 FOTS Noise Figure ................................................................................... 65
4.8.2 IF Switch Noise Figure ............................................................................. 65
4.8.3 Cable Passive Noise Figure ...................................................................... 67
4.8.4 System Total Noise Figure........................................................................ 68
4.9 SSAR-IF Output VSWR ....................................................................................... 69
5. CONTROL AND MONITOR CRITERIA................................................................... 71
5.1 SSAR-IF Infrastructure Fault Detection –IF Switch ............................................ 71
5.2 SSAR-IF Infrastructure TOCC Control and Monitor ........................................... 72
5.2.1 WSGT IF Switch Control and Status (from STGT) ................................. 72
5.2.2 WSGT IF Switch Control and Status (from WSGT) ................................ 74
5.2.3 GRGT IF Switch Control and Status (from WSGT) ................................ 75
5.3 SSAR-IF Infrastructure Control and Monitor – Local.......................................... 76
5.3.1 WSGT IF Switch Local Control and Status.............................................. 76
5.3.2 GRGT IF Switch Local Control and Status .............................................. 77
5.4 WSGT IF Switch Control via Multiple ADPE’s. ................................................. 77
5.4.1 WSGT/STGT Staggered Control of the IF Switch ................................... 79
5.4.2 WSGT/STGT Simultaneous Control of the IF Switch ............................. 79
6. TEST EQUIPMENT CALIBRATION LIST ............................................................... 80
7. CUSTOMER VALIDATION OF REQUIREMENTS................................................. 81

SSAR-IF System Test Procedure 2


EC-8412CH1
3/30/07
1. TEST METHODOLGY
Several of the system tests can be run concurrently to maximize time utilization. For
example, Gain Flatness, Gain Slope and 3 dB Bandwidth tests can be run at the same
time using essentially the same test setup.

The RF Test Matrix chart illustrated in Table 1.1 indicates which RF tests may be run
concurrently with the same test setup to maximize time utilization.

Sequence
Section Test
A B C D
4.1 Gain Flatness
4.2 Gain Slope
4.3 3 dB Bandwidth
4.4 Infrastructure IF Frequency
4.5 IF Output Level
4.5.1 One-to-One Test
4.5.2 One-to-Many Test
4.6 Spurious Outputs
4.7 Infrastructure AM/PM
4.8 Infrastructure Noise Figure
4.9 SSAR-IF Output VSWR

Table 1.1
RF Test Matrix

SSAR-IF System Test Procedure 3


EC-8412CH1
3/30/07
STGT WSGT GRGT

SSA-1A 370MHz IF
IF SWITCH

SSA-1B 370MHz IF

PATCHPANEL
FIBER AMPLIFIER
IF SWITCH
SSAR IF

FIBER DEMUX
370MHz 370MHz

PATCHPANEL

PATCHPANEL
SSA-2A 370MHz IF

FIBER MUX
IF SWITCH IF SWITCH IF
SSAR IF USER 16x16 USER
FOTS

FOTS
SSA-2B 370MHz IF SWITCH RETURN RETURN
IF SWITCH 32x32
SGLT-1
C&S
SGLT-2

SGLT-3 C&S
PATCHPANEL

PATCHPANEL

SGLT-4 SGLT-6

SGLT-5

GRGT
LI SWITCH
CONTROLLER
(GLISC)
STGT CTFS WSGT CTFS
FOTS

STGT RS-422
FOTS

SSC-A SSC-A IF SWITCH


IF SWITCH AUTO GDIS GDIS CONTROLLER
CONTROLLER SWITCH FUNCTION
STGT CTFS WSGT CTFS
SSC-B (SISC) SSC-B

STGT WSGT LEGEND


DIS EXISTING DIS
ADPE Ka IF SWITCH ADPE EXISTING EQUIPMENT
MODIFIED EQUIPMENT
NEW EQUIPMENT
EXISTING INTERFACE

Figure 1.1
WSC SSAR-IF Infrastructure

SSAR-IF System Test Procedure 4


EC-8412CH1
3/30/07
2. TEST EQUIPMENT
Table 2.1 lists all relevant test equipment. (Equivalent test equipment may be used)
Supply utilized test equipment calibration data in the Test Equipment Calibration List,
Section 6.

Item Vendor Test Equipment


1 Agilent E4440A Spectrum Analyzer 3 Hz-26.5 GHz
2 Agilent ESG-D3000A Signal Generator
3 HP HP5350B Microwave Frequency Counter
4 Anaren Dbl Balanced Mixer, 74129
5 Mini-Circuits Splitter, 15542 (ZMSC-2-2)
6 HP HP8970B Noise Figure Meter
7 HP HP346B Noise Source
8 HP HP8508A Vector Voltmeter or
9 HP HP8720B Network Analyzer
10 Wiltron 60NF50 SWR Bridge

Table 2.1
SSAR-IF Test Equipment

SSAR-IF System Test Procedure 5


EC-8412CH1
3/30/07
3. USS SSA/KSA IF SWITCH MODIFICATION LEVELS
Pre/Post installation testing of the -6dB directional coupler in the USS SSA/KSA IF
Switches

Test Type: Unit

Procedure:
Disconnect the input cable from Power Splitter #3 (PS3) input port “S”, and
connect/inject a 370 MHz, –30dBm CW signal subtracting the test cables’ loss.
Configure the E4440A Spectrum Analyzer to a center frequency of 370 MHz, and a
bandwidth of 17 MHz.
- For Pre Modification Measurement…
o Connect the Spectrum Analyzer to the Front Panel Test Point “Pre Demod
Out”.

- For Post Modification measurements…


o For KSA, connect the Spectrum Analyzer to the Front Panel Test Point
“Pre Demod Out” and to the chassis rear J11 IF Out (SMA).
o For SSA, connect the Spectrum Analyzer to the new J24, Rack I/O Panel
IF Out.

PRE Modification POST Modification


Pre Demod Pre Demod Rear Panel -J11
Out Out

SGLT-1 SSA1 ‘A’: __-34.4__ dBm __-38.6__ dBm __-36.0__ dBm


SN _AGD1015_ Coupler SN _0618 002_

SGLT-1 SSA1 ‘B’: __-34.2__ dBm __-39.0__ dBm __-36.0__ dBm


SN _AGD1003_ Coupler SN _0618 003_

SGLT-1 SSA2 ‘A’: __-34.4__ dBm __-39.5__ dBm __-36.0__ dBm


SN _AGD1013_ Coupler SN _0618 004_

SGLT-1 SSA2 ‘B’: __-34.3__ dBm __-39.5__ dBm __-35.9__ dBm


SN _AGD1001_ Coupler SN _0618 005_

SGLT-1 KSA1 ‘A’: __-34.4__ dBm __-38.2__ dBm __-35.6__ dBm


SN _AGD0012_ Coupler SN _0620 011_

SGLT-1 KSA1 ‘B’: __-34.3__ dBm __-38.3__ dBm __-35.7__ dBm


SN _AGD0002_ Coupler SN _0620 012_

SGLT-1 KSA2 ‘A’: __-34.3__ dBm __-39.2__ dBm __-35.2__ dBm


SN _AGD0034_ Coupler SN _0620 015_

SSAR-IF System Test Procedure 6


EC-8412CH1
3/30/07
SGLT-1 KSA2 ‘B’: __-34.3__ dBm __-38.4__ dBm __-35.5__ dBm
SN _AGD0031_ Coupler SN _0624 001_

SGLT-2 SSA1 ‘A’: __-34.3__ dBm __-39.0__ dBm __-35.9__ dBm


SN _AGD1011_ Coupler SN _0620 001_

SGLT-2 SSA1 ‘B’: __-35.4 _ dBm __-39.2__ dBm __-35.9__ dBm


SN _AGD1037_ Coupler SN _0620 002_

SGLT-2 SSA2 ‘A’: __-35.6__ dBm __-38.8__ dBm __-36.1__ dBm


SN _AGD1035_ Coupler SN _0610 012_

SGLT-2 SSA2 ‘B’: __-35.6__ dBm __-39.3__ dBm __-35.9__ dBm


SN _AGD1033_ Coupler SN _0610 013_

SGLT-2 KSA1 ‘A’: __-35.3__ dBm __-38.6__ dBm __-35.2__ dBm


SN _AGD0037_ Coupler SN _0618 008_

SGLT-2 KSA1 ‘B’: __-35.2__ dBm __-38.9__ dBm __-35.0__ dBm


SN _AGD0039_ Coupler SN _0618 009_

SGLT-2 KSA2 ‘A’: __-35.2__ dBm __-38.4 dBm __-35.4__ dBm


SN _AGD0042_ Coupler SN _0618 010_

SGLT-2 KSA2 ‘B’: __-35.7__ dBm __-39.0__ dBm __-35.2__ dBm


SN _AGD0038_ Coupler SN _0618 011_

SGLT-3 SSA1 ‘A’: __-34.4__ dBm __-39.1__ dBm __-36.0__ dBm


SN _AGD1010_ Coupler SN _0620 003_

SGLT-3 SSA1 ‘B’: __-34.5__ dBm __-39.2__ dBm __-36.0__ dBm


SN _AGD1014_ Coupler SN _0620 004_

SGLT-3 SSA2 ‘A’: __-34.3__ dBm __-38.4__ dBm __-36.3__ dBm


SN _AGD1006_ Coupler SN _0620 005_

SGLT-3 SSA2 ‘B’: __-34.4__ dBm __-38.4__ dBm __-36.3__ dBm


SN _AGD1012_ Coupler SN _0620 006_

SGLT-3 KSA1 ‘A’: __-35.4__ dBm __-39.2__ dBm __-35.4__ dBm


SN _AGD0040_ Coupler SN _0620 007_

SGLT-3 KSA1 ‘B’: __-34.4__ dBm __-38.2__ dBm __-35.7__ dBm

SSAR-IF System Test Procedure 7


EC-8412CH1
3/30/07
SN _AGD0011_ Coupler SN _0620 008_

SGLT-3 KSA2 ‘A’: __-34.4__ dBm __-39.0__ dBm __-35.5__ dBm


SN _AGD0032_ Coupler SN _0620 009_

SGLT-3 KSA2 ‘B’: __-34.4__ dBm __-38.5__ dBm __-35.7__ dBm


SN _AGD0004_ Coupler SN _0620 010_

SGLT-4 SSA1 ‘A’: __-33.9__ dBm __-38.9__ dBm __-35.5__ dBm


SN _AGD1007_ Coupler SN _0610 002_

SGLT-4 SSA1 ‘B’: __-34.0__ dBm __-39.1__ dBm __-35.5__ dBm


SN _AGD1002_ Coupler SN _0610 008_

SGLT-4 SSA2 ‘A’: __-34.1__ dBm __-39.2__ dBm __-35.8__ dBm


SN _AGD1004_ Coupler SN _0610 001_

SGLT-4 SSA2 ‘B’: __-34.3__ dBm __-39.2__ dBm __-35.6__ dBm


SN _AGD1009_ Coupler SN _0610 003_

SGLT-4 KSA1 ‘A’: __-34.6__ dBm __-39.4__ dBm __-35.4__ dBm


SN _AGD0001_ Coupler SN _0620 013_

SGLT-4 KSA1 ‘B’: __-34.5__ dBm __-39.4__ dBm __-35.4__ dBm


SN _AGD0008_ Coupler SN _0620 014_

SGLT-4 KSA2 ‘A’: __-34.9__ dBm __-40.1__ dBm __-35.8__ dBm


SN _AGD0003_ Coupler SN _0610 010_

SGLT-4 KSA2 ‘B’: __-35.9__ dBm __-39.6__ dBm __-35.8__ dBm


SN _AGD0041_ Coupler SN _0610 007_

SGLT-5 SSA1 ‘A’: __-34.3__ dBm __-38.8__ dBm __-36.0__ dBm


SN _AGD1008_ Coupler SN _0610 004_

SGLT-5 SSA1 ‘B’: __-34.3__ dBm __-39.4__ dBm __-35.8__ dBm


SN _AGD1005_ Coupler SN _0610 006_

SGLT-5 SSA2 ‘A’: __-35.6__ dBm __-38.9__ dBm __-35.9__ dBm


SN _AGD1036_ Coupler SN _0610 009_

SGLT-5 SSA2 ‘B’: __-34.4__ dBm __-38.4__ dBm __-36.1__ dBm


SN _AGD1016_ Coupler SN _0610 011_

SSAR-IF System Test Procedure 8


EC-8412CH1
3/30/07
SGLT-5 KSA1 ‘A’: __-34.6__ dBm __-38.5__ dBm __-35.7__ dBm
SN _AGD0007_ Coupler SN _0610 014_

SGLT-5 KSA1 ‘B’: __-34.5__ dBm __-40.1__ dBm __-35.3__ dBm


SN _AGD0005_ Coupler SN _0610 015_

SGLT-5 KSA2 ‘A’: __-34.4__ dBm __-39.2__ dBm __-35.4__ dBm


SN _AGD0033_ Coupler SN _0610 016_

SGLT-5 KSA2 ‘B’: __-34.5__ dBm __-38.8__ dBm __-35.5__ dBm


SN _AGD0006_ Coupler SN _0618 001_

SGLT-6 SSA1 ‘A’: __-35.6__ dBm __-38.7__ dBm __-36.0__ dBm


SN _AGD1034_ Coupler SN _0624 004_

SGLT-6 SSA1 ‘B’: __-35.6__ dBm __-39.6__ dBm __-35.8__ dBm


SN _AGD1038_ Coupler SN _0624 005_

SGLT-6 SSA2 ‘A’: __-35.6__ dBm __-38.9__ dBm __-35.9__ dBm


SN _AGD1040_ Coupler SN _0624 003_

SGLT-6 SSA2 ‘B’: __-35.7__ dBm __-38.6__ dBm __-36.2__ dBm


SN _AGD1039_ Coupler SN _0624 002_

SGLT-6 KSA1 ‘A’: __-35.6__ dBm __-39.0__ dBm __-35.5__ dBm


SN _AGD0044_ Coupler SN _0624 006_

SGLT-6 KSA1 ‘B’: __-35.6__ dBm __-39.0__ dBm __-35.7__ dBm


SN _AGD0043_ Coupler SN _0624 007_

SGLT-6 KSA2 ‘A’: __-34.4__ dBm __-38.5__ dBm __-35.6__ dBm


SN _AGD0013_ Coupler SN _0624 008_

SGLT-6 KSA2 ‘B’: __-34.5__ dBm __-39.4__ dBm __-35.5__ dBm


SN _AGD0009_ Coupler SN _0624 009_

SSAR-IF System Test Procedure 9


EC-8412CH1
3/30/07
4. PERFORMANCE CRITERIA
4.1 SSAR-IF Infrastructure Gain Flatness
The SSAR-IF shall meet the performance requirements specified as ≤ 0.4 dB p-p over 17
MHz center frequency sinusoidal.

Test Type: System

Configuration:

SSA1 13307.5 MHz LO


SSA2 13327.5 MHz LO
Mixer
ESG-D3000A IF RF SSA1 or SSA2 370 MHz IF USS IF
Signal
Composite Downconverter 17 MHz BW Switch
Generator
LO Input
LO Monitor
370 MHz (FP)

* FOTS * Fiber * Fiber Fiber Optic * FOTS * Fiber


TX DeMux Amp IFL TX Mux

* Used In SGLTs 1, 2, & 3 Paths Only

370 MHz E4440A


IF Switch Spectrum
Analyzer

Procedure:

Configure Signal Generator and RF Mixer per the above drawing; set the signal generator
output level to -19 dBm, frequency to 370 MHz, and step sweep +/- 10 MHz.

Connect the E4440A Spectrum Analyzer to the output of the IF Switch. Configure the IF
switch matrix to the correct position.

Configure the E4440A Spectrum Analyzer to a center frequency of 370 MHz, and a
bandwidth of 17 MHz. Adjust amplitude setting to display gain flatness with maximum
resolution. Store each reading to a CSV file for use later (the E4440A Spectrum Analyzer
will store 601 or 1001 data points in the .CSV mode).

SSAR-IF System Test Procedure 10


EC-8412CH1
3/30/07
3/30/07
EC-8412CH1
Signal Level (dB) Signal Level (dB)

-0.5
-0.4
-0.3
-0.2
-0.1
0.0
0.1
0.2
0.3
0.4
0.5
-0.5
-0.4
-0.3
-0.2
-0.1
0.0
0.1
0.2
0.3
0.4
0.5

361,500,000 361,500,000

362,500,000 362,500,000

SSAR-IF System Test Procedure


363,500,000 363,500,000

364,500,000 364,500,000

365,500,000 365,500,000

366,500,000 366,500,000

367,500,000 367,500,000

368,500,000 368,500,000

369,500,000 369,500,000

370,500,000 370,500,000

Frequency (Hz)
Frequency (Hz)

371,500,000 371,500,000
SGLT-1 SSA1A 370 MHz IF

SGLT-1 SSA1B 370 MHz IF


372,500,000 372,500,000

373,500,000 373,500,000

374,500,000 374,500,000

375,500,000 375,500,000
SGLT-1 SSA1 ‘A’ Gain Flatness: _0.25 dB (p-p)

SGLT-1 SSA1 ‘B’ Gain Flatness: _0.35_ dB (p-p)


376,500,000 376,500,000

377,500,000 377,500,000

378,500,000 378,500,000

11
3/30/07
EC-8412CH1
Signal Level (dB) Signal Level (dB)

-0.5
-0.4
-0.3
-0.2
-0.1
-0.5
-0.4
-0.3
-0.2
-0.1

0.0
0.1
0.2
0.3
0.4
0.5
0.0
0.1
0.2
0.3
0.4
0.5

361,500,000 361,500,000

362,500,000 362,500,000

SSAR-IF System Test Procedure


363,500,000 363,500,000

364,500,000 364,500,000

365,500,000 365,500,000

366,500,000 366,500,000

367,500,000 367,500,000

368,500,000 368,500,000

369,500,000 369,500,000

370,500,000 370,500,000

Frequency (Hz)
Frequency (Hz)

371,500,000 371,500,000
SGLT-1 SSA2A 370 MHz IF

SGLT-1 SSA2B 370 MHz IF


372,500,000 372,500,000

373,500,000 373,500,000

374,500,000 374,500,000

375,500,000 375,500,000

SGLT-1 SSA2 ‘B’ Gain Flatness: _0.46_ dB (p-p)


SGLT-1 SSA2 ‘A’ Gain Flatness: _0.38_ dB (p-p)

376,500,000 376,500,000

377,500,000 377,500,000

378,500,000 378,500,000

12
3/30/07
EC-8412CH1
Signal Level (dB) Signal Level (dB)

-0.5
-0.4
-0.3
-0.2
-0.1
-0.5
-0.4
-0.3
-0.2
-0.1

0.0
0.1
0.2
0.3
0.4
0.5
0.0
0.1
0.2
0.3
0.4
0.5

361,500,000 361,500,000

362,500,000 362,500,000

SSAR-IF System Test Procedure


363,500,000 363,500,000

364,500,000 364,500,000

365,500,000 365,500,000

366,500,000 366,500,000

367,500,000 367,500,000

368,500,000 368,500,000

369,500,000 369,500,000

370,500,000 370,500,000

Frequency (Hz)
Frequency (Hz)

371,500,000 371,500,000
SGLT-2 SSA1A 370 MHz IF

SGLT-2 SSA1B 370 MHz IF


372,500,000 372,500,000

373,500,000 373,500,000

374,500,000 374,500,000

375,500,000 375,500,000

SGLT-2 SSA1 ‘B’ Gain Flatness: _0.45_ dB (p-p)


SGLT-2 SSA1 ‘A’ Gain Flatness: _0.29_ dB (p-p)

376,500,000 376,500,000

377,500,000 377,500,000

378,500,000 378,500,000

13
3/30/07
EC-8412CH1
Signal Level (dB) Signal Level (dB)

-0.5
-0.4
-0.3
-0.2
-0.1
-0.5
-0.4
-0.3
-0.2
-0.1

0.0
0.1
0.2
0.3
0.4
0.5
0.0
0.1
0.2
0.3
0.4
0.5

361,500,000 361,500,000

362,500,000 362,500,000

SSAR-IF System Test Procedure


363,500,000 363,500,000

364,500,000 364,500,000

365,500,000 365,500,000

366,500,000 366,500,000

367,500,000 367,500,000

368,500,000 368,500,000

369,500,000 369,500,000

370,500,000 370,500,000

Frequency (Hz)
Frequency (Hz)

371,500,000 371,500,000
SGLT-2 SSA2A 370 MHz IF

SGLT-2 SSA2B 370 MHz IF


372,500,000 372,500,000

373,500,000 373,500,000

374,500,000 374,500,000

375,500,000 375,500,000

SGLT-2 SSA2 ‘B’ Gain Flatness: _0.33_ dB (p-p)


SGLT-2 SSA2 ‘A’ Gain Flatness: _0.27_ dB (p-p)

376,500,000 376,500,000

377,500,000 377,500,000

378,500,000 378,500,000

14
3/30/07
EC-8412CH1
Signal Level (dB) Signal Level (dB)

-0.5
-0.4
-0.3
-0.2
-0.1
-0.5
-0.4
-0.3
-0.2
-0.1

0.0
0.1
0.2
0.3
0.4
0.5
0.0
0.1
0.2
0.3
0.4
0.5

361,500,000 361,500,000

362,500,000 362,500,000

SSAR-IF System Test Procedure


363,500,000 363,500,000

364,500,000 364,500,000

365,500,000 365,500,000

366,500,000 366,500,000

367,500,000 367,500,000

368,500,000 368,500,000

369,500,000 369,500,000

370,500,000 370,500,000

Frequency (Hz)
Frequency (Hz)

371,500,000 371,500,000
SGLT-3 SSA1A 370 MHz IF

SGLT-3 SSA1B 370 MHz IF


372,500,000 372,500,000

373,500,000 373,500,000

374,500,000 374,500,000

375,500,000 375,500,000

SGLT-3 SSA1 ‘B’ Gain Flatness: _0.29_ dB (p-p)


376,500,000 376,500,000
SGLT- 3 SSA1 ‘A’ Gain Flatness: _0.34_ dB (p-p)

377,500,000 377,500,000

378,500,000 378,500,000

15
3/30/07
EC-8412CH1
Signal Level (dB) Signal Level (dB)

-0.5
-0.4
-0.3
-0.2
-0.1
0.0
0.1
0.2
0.3
0.4
0.5

-0.5
-0.4
-0.3
-0.2
-0.1
0.0
0.1
0.2
0.3
0.4
0.5
361,500,000 361,500,000

362,500,000 362,500,000

SSAR-IF System Test Procedure


363,500,000 363,500,000

364,500,000 364,500,000

365,500,000 365,500,000

366,500,000 366,500,000

367,500,000 367,500,000

368,500,000 368,500,000

369,500,000 369,500,000

370,500,000 370,500,000

Frequency (Hz)
Frequency (Hz)

371,500,000 371,500,000
SGLT-3 SSA2A 370 MHz IF

SGLT-3 SSA2B 370 MHz IF


372,500,000 372,500,000

373,500,000 373,500,000

CDS DR 45018 1/4/07 MWO 1083721


374,500,000 374,500,000

375,500,000 375,500,000
SGLT-3 SSA2 ‘A’ Gain Flatness: _0.25_ dB (p-p)

376,500,000 376,500,000

SGLT-3 SSA2 ‘B’ Gain Flatness: ___-____ dB (p-p)


377,500,000 377,500,000

378,500,000 378,500,000

16
3/30/07
EC-8412CH1
Signal Level (dB) Signal Level (dB)

-0.5
-0.4
-0.3
-0.2
-0.1
-0.5
-0.4
-0.3
-0.2
-0.1

0.0
0.1
0.2
0.3
0.4
0.5
0.0
0.1
0.2
0.3
0.4
0.5

361,500,000 361,500,000

362,500,000 362,500,000

SSAR-IF System Test Procedure


363,500,000 363,500,000

364,500,000 364,500,000

365,500,000 365,500,000

366,500,000 366,500,000

367,500,000 367,500,000

368,500,000 368,500,000

369,500,000 369,500,000

370,500,000 370,500,000

Frequency (Hz)
Frequency (Hz)
371,500,000 371,500,000
SGLT-4 SSA1A 370 MHz IF

SGLT-4 SSA1B 370 MHz IF


372,500,000 372,500,000

373,500,000 373,500,000

374,500,000 374,500,000

375,500,000 375,500,000

SGLT-4 SSA1 ‘B’ Gain Flatness: _0.39_ dB (p-p)


SGLT-4 SSA1 ‘A’ Gain Flatness: _0.35_ dB (p-p)

376,500,000 376,500,000

377,500,000 377,500,000

378,500,000 378,500,000

17
3/30/07
EC-8412CH1
Signal Level (dB) Signal Level (dB)

-0.5
-0.4
-0.3
-0.2
-0.1
-0.5
-0.4
-0.3
-0.2
-0.1

0.0
0.1
0.2
0.3
0.4
0.5
0.0
0.1
0.2
0.3
0.4
0.5

361,500,000 361,500,000

362,500,000 362,500,000

SSAR-IF System Test Procedure


363,500,000 363,500,000

364,500,000 364,500,000

365,500,000 365,500,000

366,500,000 366,500,000

367,500,000 367,500,000

368,500,000 368,500,000

369,500,000 369,500,000

370,500,000 370,500,000

Frequency (Hz)
Frequency (Hz)

371,500,000 371,500,000
SGLT-4 SSA2A 370 MHz IF

SGLT-4 SSA2B 370 MHz IF


372,500,000 372,500,000

373,500,000 373,500,000

374,500,000 374,500,000

375,500,000 375,500,000

SGLT-4 SSA2 ‘B’ Gain Flatness: _0.36_ dB (p-p)


SGLT-4 SSA2 ‘A’ Gain Flatness: _0.31_ dB (p-p)

376,500,000 376,500,000

377,500,000 377,500,000

378,500,000 378,500,000

18
3/30/07
EC-8412CH1
Signal Level (dB) Signal Level (dB)

-0.5
-0.4
-0.3
-0.2
-0.1
-0.5
-0.4
-0.3
-0.2
-0.1

0.0
0.1
0.2
0.3
0.4
0.5
0.0
0.1
0.2
0.3
0.4
0.5

361,500,000 361,500,000

362,500,000 362,500,000

SSAR-IF System Test Procedure


363,500,000 363,500,000

364,500,000 364,500,000

365,500,000 365,500,000

366,500,000 366,500,000

367,500,000 367,500,000

368,500,000 368,500,000

369,500,000 369,500,000

370,500,000 370,500,000

Frequency (Hz)
Frequency (Hz)

371,500,000 371,500,000
SGLT-5 SSA1A 370 MHz IF

SGLT-5 SSA1B 370 MHz IF


372,500,000 372,500,000

373,500,000 373,500,000

374,500,000 374,500,000

375,500,000 375,500,000

SGLT-5 SSA1 ‘B’ Gain Flatness: _0.34_ dB (p-p)


SGLT-5 SSA1 ‘A’ Gain Flatness: _0.36_ dB (p-p)

376,500,000 376,500,000

377,500,000 377,500,000

378,500,000 378,500,000

19
3/30/07
EC-8412CH1
Signal Level (dB) Signal Level (dB)

-0.5
-0.4
-0.3
-0.2
-0.1
-0.5
-0.4
-0.3
-0.2
-0.1

0.0
0.1
0.2
0.3
0.4
0.5
0.0
0.1
0.2
0.3
0.4
0.5

361,500,000 361,500,000

362,500,000 362,500,000

SSAR-IF System Test Procedure


363,500,000 363,500,000

364,500,000 364,500,000

365,500,000 365,500,000

366,500,000 366,500,000

367,500,000 367,500,000

368,500,000 368,500,000

369,500,000 369,500,000

370,500,000 370,500,000

Frequency (Hz)
Frequency (Hz)

371,500,000 371,500,000
SGLT-5 SSA2A 370 MHz IF

SGLT-5 SSA2B 370 MHz IF


372,500,000 372,500,000

373,500,000 373,500,000

374,500,000 374,500,000

375,500,000 375,500,000

SGLT-5 SSA2 ‘B’ Gain Flatness: _0.36_ dB (p-p)


SGLT-5 SSA2 ‘A’ Gain Flatness: _0.38_ dB (p-p)

376,500,000 376,500,000

377,500,000 377,500,000

378,500,000 378,500,000

20
3/30/07
EC-8412CH1
Signal Level (dB) Signal Level (dB)

-0.5
-0.4
-0.3
-0.2
-0.1
-0.5
-0.4
-0.3
-0.2
-0.1

0.0
0.1
0.2
0.3
0.4
0.5
0.0
0.1
0.2
0.3
0.4
0.5

361,500,000 361,500,000

362,500,000 362,500,000

SSAR-IF System Test Procedure


363,500,000 363,500,000

364,500,000 364,500,000

365,500,000 365,500,000

366,500,000 366,500,000

367,500,000 367,500,000

368,500,000 368,500,000

369,500,000 369,500,000

370,500,000 370,500,000

Frequency (Hz)
Frequency (Hz)

371,500,000 371,500,000
SGLT-6 SSA1A 370 MHz IF

SGLT-6 SSA1B 370 MHz IF


372,500,000 372,500,000

373,500,000 373,500,000

374,500,000 374,500,000

375,500,000 375,500,000

SGLT-6 SSA1 ‘B’ Gain Flatness: _0.18_ dB (p-p)


SGLT-6 SSA1 ‘A’ Gain Flatness: _0.13_ dB (p-p)

376,500,000 376,500,000

377,500,000 377,500,000

378,500,000 378,500,000

21
3/30/07
EC-8412CH1
Signal Level (dB) Signal Level (dB)

-0.5
-0.4
-0.3
-0.2
-0.1
-0.5
-0.4
-0.3
-0.2
-0.1

0.0
0.1
0.2
0.3
0.4
0.5
0.0
0.1
0.2
0.3
0.4
0.5

361,500,000 361,500,000

362,500,000 362,500,000

SSAR-IF System Test Procedure


363,500,000 363,500,000

364,500,000 364,500,000

365,500,000 365,500,000

366,500,000 366,500,000

367,500,000 367,500,000

368,500,000 368,500,000

369,500,000 369,500,000

370,500,000 370,500,000

Frequency (Hz)
Frequency (Hz)

371,500,000 371,500,000
SGLT-6 SSA2A 370 MHz IF

SGLT-6 SSA2B 370 MHz IF


372,500,000 372,500,000

373,500,000 373,500,000

374,500,000 374,500,000

375,500,000 375,500,000

SGLT-6 SSA2 ‘B’ Gain Flatness: _0.15_ dB (p-p)


SGLT-6 SSA2 ‘A’ Gain Flatness: _0.08_ dB (p-p)

376,500,000 376,500,000

377,500,000 377,500,000

378,500,000 378,500,000

22
4.2 SSAR-IF Infrastructure Gain Slope
The SSAR-IF shall meet the performance requirements specified as ≤ 0.1 dB/MHz over
17 MHz center frequency.

Test Type: System

Configuration:
SSA1 13307.5 MHz LO
SSA2 13327.5 MHz LO
Mixer
ESG-D3000A IF RF SSA1 or SSA2 370 MHz IF USS IF
Signal
Composite Downconverter 17 MHz BW Switch
Generator
LO Input
LO Monitor
370 MHz (FP)

* FOTS * Fiber * Fiber Fiber Optic * FOTS * Fiber


TX DeMux Amp IFL TX Mux

* Used In SGLTs 1, 2, & 3 Paths Only

370 MHz E4440A


IF Switch Spectrum
Analyzer

Procedure:
NOTE: Data may be used from the previous gain flatness test to measure gain slope. If
this test is being conducted independently, please follow these steps:

Configure Signal Generator and RF Mixer per the above drawing; set the signal generator
output level to -19 dBm, frequency to 370 MHz, and step sweep +/- 10 MHz.

Connect the E4440A Spectrum Analyzer to the output of the IF Switch. Configure the IF
switch matrix to the correct position.

Configure the E4440A Spectrum Analyzer to a center frequency of 370 MHz, and a
bandwidth of 17 MHz. Adjust amplitude setting to display gain flatness with maximum
resolution. Store each reading to a CSV file for use later (the E4440A Spectrum Analyzer
will store 601 data points in the .CSV mode).

Locate an area within the bandwidth that indicates raw maximum gain slope. Compute
the gain slope using the following process:

Using the equation for a straight line:


y = mx + b

The straight line of best fit to the worst-case slope observed on the plot will produce the
following results:
m =x/y (rise/run)

SSAR-IF System Test Procedure 23


EC-8412CH1
3/30/07
SGLT-1 SSA1 ‘A’
Data Point: Data Point: Rise/Run
- 0.084 dB/ 365.325 MHz 0.095 dB/ 363.676 MHz 0.179 dB/ 1.649 MHz

Record the SGLT-1 SSA1 ‘A’ gain slope: _0.109_ dB/MHz

SGLT-1 SSA1 ‘B’


Data Point: Data Point: Rise/Run
0.032 dB/ 368.572 MHz - 0.051 dB/ 367.501 MHz 0.083 dB/ 1.071 MHz

Record the SGLT-1 SSA1 ‘B’ gain slope: _0.077_ dB/MHz

SGLT-1 SSA2 ‘A’


Data Point: Data Poin: Rise/Run
- 0.007 dB/ 369.592 MHz - 0.126 dB/ 368.096 MHz 0.119 dB/ 1.496 MHz

Record the SGLT-1 SSA2 ‘A’ gain slope: _0.080_ dB/MHz

SGLT-1 SSA2 ‘B’


Data Point: Data Point: Rise/Run
0.087 dB/ 370.187 MHz - 0.036 dB/ 368.487 MHz 0.123 dB/ 1.700 MHz

Record the SGLT-1 SSA2 ‘B’ gain slope: _0.072_ dB/MHz

SGLT-2 SSA1 ‘A’


Data Point: Data Point: Rise/Run
0.024 dB/ 366.175 MHz 0.104 dB/ 364.560 MHz 0.080 dB/ 1.615 MHz

Record the SGLT-2 SSA1 ‘A’ gain slope: _0.050_ dB/MHz

SGLT-2 SSA1 ‘B’


Data Point: Data Point: Rise/Run
- 0.083 dB/ 367.620 MHz 0.221 dB/ 366.175 MHz 0.304 dB/ 1.445 MHz

Record the SGLT-2 SSA1 ‘B’ gain slope: _0.210_ dB/MHz

SGLT-2 SSA2 ‘A’


Data Point: Data Point: Rise/Run
0.057 dB/ 363.540 MHz 0.179 dB/ 362.095 MHz 0.122 dB/ 1.445 MHz

Record the SGLT-2 SSA2 ‘A’ gain slope: _0.084_ dB/MHz

SGLT-2 SSA2 ‘B’


Data Point: Data Point: Rise/Run
0.053 dB/ 364.220 MHz 0.158 dB/ 362.435 MHz 0.105 dB/ 1.785 MHz

SSAR-IF System Test Procedure 24


EC-8412CH1
3/30/07
Record the SGLT-2 SSA2 ‘B’ gain slope: _0.059_ dB/MHz

SGLT-3 SSA1 ‘A’


Data Point: Data Point: Rise/Run
- 0.129 dB/ 369.830 MHz - 0.048 dB/ 367.960 MHz 0.177 dB/ 1.870 MHz

Record the SGLT-3 SSA1 ‘A’ gain slope: _0.095_ dB/MHz

SGLT-3 SSA1 ‘B’


Data Point: Data Point: Rise/Run
0.098 dB/ 366.203 MHz 0.190 dB/ 364.447 MHz 0.092 dB/ 1.756 MHz

Record the SGLT-3 SSA1 ‘B’ gain slope: _0.052_ dB/MHz

SGLT-3 SSA2 ‘A’


Data Point: Data Point: Rise/Run
0.070 dB/ 365.467 MHz 0.163 dB/ 364.532 MHz 0.093 dB/ 0.935 MHz

Record the SGLT-3 SSA2 ‘A’ gain slope: _0.099_ dB/MHz

SGLT-3 SSA2 ‘B’


CDS DR 45018 1/4/07 MWO 1083721
Data Point: Data Point: Rise/Run
- ______ dB/_______ MHz - _______ dB/_______ MHz ______ dB/ _______MHz

Record the SGLT-3 SSA2 ‘B’ gain slope: __-___ dB/MHz

SGLT-4 SSA1 ‘A’


Data Point: Data Point: Rise/Run
- 0.070 dB/ 372.125 MHz - 0.011 dB/ 370.680 MHz 0.059 dB/ 1.445 MHz

Record the SGLT-4 SSA1 ‘A’ gain slope: _0.041_ dB/MHz

SGLT-4 SSA1 ‘B’


Data Point: Data Point: Rise/Run
- 0.007 dB/ 368.753 MHz 0.102 dB/ 367.337 MHz 0.109 dB/ 1.416 MHz

Record the SGLT-4 SSA1 ‘B’ gain slope: _0.077_ dB/MHz

SGLT-4 SSA2 ‘A’


Data Point: Data Point: Rise/Run
0.046 dB/ 365.098 MHz 0.150 dB/ 362.860 MHz 0.104 dB/ 2.238 MHz

Record the SGLT-4 SSA2 ‘A’ gain slope: _0.046_ dB/MHz

SSAR-IF System Test Procedure 25


EC-8412CH1
3/30/07
SGLT-4 SSA2 ‘B’
Data Point: Data Point: Rise/Run
0.011 dB/ 366.968 MHz 0.116 dB/ 365.552 MHz 0.105 dB/ 1.416 MHz

Record the SGLT-4 SSA2 ‘B’ gain slope: _0.074_ dB/MHz

SGLT-5 SSA1 ‘A’


Data Point: Data Point: Rise/Run
0.067 dB/ 363.597 MHz 0.143 dB/ 362.435 MHz 0.076 dB/ 1.162 MHz

Record the SGLT-5 SSA1 ‘A’ gain slope: _0.065_ dB/MHz

SGLT-5 SSA1 ‘B’


Data Point: Data Point: Rise/Run
0.062 dB/ 363.313 MHz 0.142 dB/ 361.727 MHz 0.080 dB/ 1.586 MHz

Record the SGLT-5 SSA1 ‘B’ gain slope: _0.050_ dB/MHz

SGLT-5 SSA2 ‘A’


Data Point: Data Point: Rise/Run
- 0.002 dB/ 369.348 MHz 0.103 dB/ 367.762 MHz 0.105 dB/ 1.586 MHz

Record the SGLT-5 SSA2 ‘A’ gain slope: _0.066_ dB/MHz

SGLT-5 SSA2 ‘B’


Data Point: Data Point: Rise/Run
- 0.080 dB/ 371.700 MHz - 0.026 dB/ 370.142 MHz 0.054 dB/ 1.558 MHz

Record the SGLT-5 SSA2 ‘B’ gain slope: _0.035_ dB/MHz

SGLT-6 SSA1 ‘A’


Data Point: Data Point: Rise/Run
- 0.106 dB/ 366.498 MHz - 0.001 dB/ 368.674 MHz 0.105 dB/ 2.176 MHz

Record the SGLT-6 SSA1 ‘A’ gain slope: _0.048_ dB/MHz

SGLT-6 SSA1 ‘B’


Data Point: Data Point: Rise/Run
- 0.087 dB/ 375.814 MHz - 0.241 dB/ 378.398 MHz 0.154 dB/ 2.584 MHz

Record the SGLT-6 SSA1 ‘B’ gain slope: _0.060_ dB/MHz

SGLT-6 SSA2 ‘A’


Data Point: Data Point: Rise/Run
- 0.080 dB/ 368.232 MHz 0.026 dB/ 369.949 MHz 0.106 dB/ 1.717 MHz

SSAR-IF System Test Procedure 26


EC-8412CH1
3/30/07
Record the SGLT-6 SSA2 ‘A’ gain slope: _0.062_ dB/MHz

SGLT-6 SSA2 ‘B’


Data Point: Data Point: Rise/Run
- 0.122 dB/ 365.614 MHz 0.002 dB/ 367.569 MHz 0.124 dB/ 1.955 MHz

Record the SGLT-6 SSA2 ‘B’ gain slope: _0.063_ dB/MHz

4.3 SSAR-IF Infrastructure 3 dB Bandwidth


The SSAR-IF shall be capable of receiving a 370 MHz SSAR signal at S-band with a 3
dB bandwidth ≥ 17 MHz.

Test Type: System

Configuration:

SSA1 13307.5 MHz LO


SSA2 13327.5 MHz LO
Mixer
ESG-D3000A IF RF SSA1 or SSA2 370 MHz IF USS IF
Signal
Composite Downconverter 17 MHz BW Switch
Generator
LO Input
LO Monitor
370 MHz (FP)

* FOTS * Fiber * Fiber Fiber Optic * FOTS * Fiber


TX DeMux Amp IFL TX Mux

* Used In SGLTs 1, 2, & 3 Paths Only

370 MHz E4440A


IF Switch Spectrum
Analyzer

Procedure:
Configure Signal Generator and RF Mixer per the above drawing; set the signal generator
output level to -19 dBm, frequency to 370 MHz, and step sweep +/- 20 MHz.

Connect the E4440A Spectrum Analyzer to the output of the IF Switch. Configure the IF
switch matrix to the correct position.

Configure the E4440A Spectrum Analyzer to a center frequency of 370 MHz, and a
bandwidth of 35 MHz. Store each reading to a CSV file for use later (the E4440A
Spectrum Analyzer will store 601 data points in the .CSV mode).

SSAR-IF System Test Procedure 27


EC-8412CH1
3/30/07
SGLT-1 SSA1A 370 MHz IF 3dB BW

-16.00

-17.00

-18.00
Signal Level (dBm)

-19.00

-20.00
Signal Level
3dB BW Marker
-21.00

-22.00

-23.00

-24.00

-25.00
352,500,000

355,000,000

357,500,000

360,000,000

362,500,000

365,000,000

367,500,000

370,000,000

372,500,000

375,000,000

377,500,000

380,000,000

382,500,000

385,000,000

387,500,000
Frequency (Hz)

SGLT-1 SSA1 ‘A’ 3 dB BW: _24.1_ MHz

SGLT-1 SSA1B 370 MHz IF 3dB BW

-16.00

-17.00

-18.00
Signal Level (dBm)

-19.00

-20.00
Signal Level
3dB BW Marker
-21.00

-22.00

-23.00

-24.00

-25.00
352,500,000

355,000,000

357,500,000

360,000,000

362,500,000

365,000,000

367,500,000

370,000,000

372,500,000

375,000,000

377,500,000

380,000,000

382,500,000

385,000,000

387,500,000

Frequency (Hz)

SGLT-1 SSA1 ‘B’ 3 dB BW: _23.8_ MHz

SSAR-IF System Test Procedure 28


EC-8412CH1
3/30/07
SGLT-1 SSA2A 370 MHz IF 3dB BW

-16.00

-17.00

-18.00
Signal Level (dBm)

-19.00

-20.00
Signal Level
3dB BW Marker
-21.00

-22.00

-23.00

-24.00

-25.00
352,500,000

355,000,000

357,500,000

360,000,000

362,500,000

365,000,000

367,500,000

370,000,000

372,500,000

375,000,000

377,500,000

380,000,000

382,500,000

385,000,000

387,500,000
Frequency (Hz)

SGLT-1 SSA2 ‘A’ 3 dB BW: _24.6_ MHz

SGLT-1 SSA2B 370 MHz IF 3dB BW

-16.00

-17.00

-18.00
Signal Level (dBm)

-19.00

-20.00
Signal Level
3dB BW Marker
-21.00

-22.00

-23.00

-24.00

-25.00
352,500,000

355,000,000

357,500,000

360,000,000

362,500,000

365,000,000

367,500,000

370,000,000

372,500,000

375,000,000

377,500,000

380,000,000

382,500,000

385,000,000

387,500,000

Frequency (Hz)

SGLT-1 SSA2 ‘B’ 3 dB BW: _25.1_ MHz

SSAR-IF System Test Procedure 29


EC-8412CH1
3/30/07
3/30/07
Signal Level (dBm) Signal Level (dBm)

EC-8412CH1
-25.00
-23.00
-21.00
-19.00
-17.00
-15.00
-13.00
-25.00
-24.00
-23.00
-22.00
-21.00
-20.00
-19.00
-18.00
-17.00
-16.00
-15.00

352,500,000 352,500,000

355,000,000 355,000,000

SSAR-IF System Test Procedure


357,500,000 357,500,000

360,000,000 360,000,000

362,500,000 362,500,000

365,000,000 365,000,000

367,500,000 367,500,000

370,000,000 370,000,000

372,500,000 372,500,000

Frequency (Hz)
Frequency (Hz)
375,000,000 375,000,000

377,500,000 377,500,000

380,000,000 380,000,000
SGLT-2 SSA1A 370 MHz IF 3dB BW

SGLT-2 SSA1B 370 MHz IF 3dB BW


382,500,000 382,500,000

385,000,000 385,000,000

387,500,000 387,500,000

SGLT-2 SSA1 ‘B’ 3 dB BW: _23.3_ MHz


SGLT-2 SSA1 ‘A’ 3 dB BW: _24.2_ MHz

Signal Level
Signal Level

3dB BW Marker
3dB BW Marker

30
3/30/07
Signal Level (dBm) Signal Level (dBm)

EC-8412CH1
-25.00
-23.00
-21.00
-19.00
-17.00
-15.00
-25.00
-23.00
-21.00
-19.00
-17.00
-15.00
352,500,000 352,500,000

355,000,000 355,000,000

SSAR-IF System Test Procedure


357,500,000 357,500,000

360,000,000 360,000,000

362,500,000 362,500,000

365,000,000 365,000,000

367,500,000 367,500,000

370,000,000 370,000,000

372,500,000 372,500,000

Frequency (Hz)
Frequency (Hz)
375,000,000 375,000,000

377,500,000 377,500,000

380,000,000 380,000,000
SGLT-2 SSA2A 370 MHz IF 3dB BW

SGLT-2 SSA2B 370 MHz IF 3dB BW


382,500,000 382,500,000

385,000,000 385,000,000

387,500,000 387,500,000

SGLT-2 SSA2 ‘B’ 3 dB BW: _24.0_ MHz


SGLT-2 SSA2 ‘A’ 3 dB BW: _27.0_ MHz

Signal Level
Signal Level

3dB BW Marker
3dB BW Marker

31
SGLT-3 SSA1A 370 MHz IF 3dB BW

-9.00

-11.00
Signal Level (dBm)

-13.00

-15.00
Signal Level
-17.00 3dB BW Marker

-19.00

-21.00

-23.00

-25.00
352,500,000

355,000,000

357,500,000

360,000,000

362,500,000

365,000,000

367,500,000

370,000,000

372,500,000

375,000,000

377,500,000

380,000,000

382,500,000

385,000,000

387,500,000
Frequency (Hz)

SGLT-3 SSA1 ‘A’ 3 dB BW: _25.6_ MHz

SGLT-3 SSA1B 370 MHz IF 3dB BW

-7.00

-9.00

-11.00
Signal Level (dBm)

-13.00

-15.00
Signal Level
3dB BW Marker
-17.00

-19.00

-21.00

-23.00

-25.00
352,500,000

355,000,000

357,500,000

360,000,000

362,500,000

365,000,000

367,500,000

370,000,000

372,500,000

375,000,000

377,500,000

380,000,000

382,500,000

385,000,000

387,500,000

Frequency (Hz)

SGLT-3 SSA1 ‘B’ 3 dB BW: _23.8_ MHz

SSAR-IF System Test Procedure 32


EC-8412CH1
3/30/07
SGLT-3 SSA2A 370 MHz IF 3dB BW

-9.00

-11.00
Signal Level (dBm)

-13.00

-15.00
Signal Level
-17.00 3dB BW Marker

-19.00

-21.00

-23.00

-25.00
352,500,000

355,000,000

357,500,000

360,000,000

362,500,000

365,000,000

367,500,000

370,000,000

372,500,000

375,000,000

377,500,000

380,000,000

382,500,000

385,000,000

387,500,000
Frequency (Hz)

SGLT-3 SSA2 ‘A’ 3 dB BW: _24.9_ MHz

~~

CDS DR 45018 1/4/07 MWO 1083721


SGLT-3 SSA2 ‘B’ 3 dB BW: _____ MHz

SSAR-IF System Test Procedure 33


EC-8412CH1
3/30/07
3/30/07
Signal Level (dBm) Signal Level (dBm)

EC-8412CH1
-25.00
-24.00
-23.00
-22.00
-21.00
-20.00
-19.00
-18.00
-17.00
-25.00
-24.00
-23.00
-22.00
-21.00
-20.00
-19.00
-18.00
-17.00

352,500,000 352,500,000

355,000,000 355,000,000

SSAR-IF System Test Procedure


357,500,000 357,500,000

360,000,000 360,000,000

362,500,000 362,500,000

365,000,000 365,000,000

367,500,000 367,500,000

370,000,000 370,000,000

372,500,000 372,500,000

Frequency (Hz)
375,000,000 Frequency (Hz) 375,000,000

377,500,000 377,500,000

380,000,000 380,000,000
SGLT-4 SSA1A 370 MHz IF 3dB BW

SGLT-4 SSA1B 370 MHz IF 3dB BW


382,500,000 382,500,000

385,000,000 385,000,000

387,500,000 387,500,000

SGLT-4 SSA1 ‘B’ 3 dB BW: _23.2_ MHz


SGLT-4 SSA1 ‘A’ 3 dB BW: _23.2_ MHz

Signal Level
Signal Level

3dB BW Marker
3dB BW Marker

34
3/30/07
Signal Level (dBm) Signal Level (dBm)

EC-8412CH1
-25.00
-24.00
-23.00
-22.00
-21.00
-20.00
-19.00
-18.00
-25.00
-24.00
-23.00
-22.00
-21.00
-20.00
-19.00
-18.00
-17.00

352,500,000 352,500,000

355,000,000 355,000,000

SSAR-IF System Test Procedure


357,500,000 357,500,000

360,000,000 360,000,000

362,500,000 362,500,000

365,000,000 365,000,000

367,500,000 367,500,000

370,000,000 370,000,000

372,500,000 372,500,000

Frequency (Hz)
Frequency (Hz)
375,000,000 375,000,000

377,500,000 377,500,000

380,000,000 380,000,000
SGLT-4 SSA2A 370 MHz IF 3dB BW

SGLT-4 SSA2B 370 MHz IF 3dB BW


382,500,000 382,500,000

385,000,000 385,000,000

387,500,000 387,500,000

SGLT-4 SSA2 ‘B’ 3 dB BW: _23.6_ MHz


SGLT-4 SSA2 ‘A’ 3 dB BW: _24.6_ MHz

Signal Level
Signal Level

3dB BW Marker
3dB BW Marker

35
3/30/07
Signal Level (dBm) Signal Level (dBm)

EC-8412CH1
-25.00
-24.00
-23.00
-22.00
-21.00
-20.00
-19.00
-18.00
-17.00
-25.00
-24.00
-23.00
-22.00
-21.00
-20.00
-19.00
-18.00
-17.00

352,500,000 352,500,000

355,000,000 355,000,000

SSAR-IF System Test Procedure


357,500,000 357,500,000

360,000,000 360,000,000

362,500,000 362,500,000

365,000,000 365,000,000

367,500,000 367,500,000

370,000,000 370,000,000

372,500,000 372,500,000

Frequency (Hz)
Frequency (Hz)
375,000,000 375,000,000

377,500,000 377,500,000

380,000,000 380,000,000
SGLT-5 SSA1A 370 MHz IF 3dB BW

SGLT-5 SSA1B 370 MHz IF 3dB BW


382,500,000 382,500,000

385,000,000 385,000,000

387,500,000 387,500,000

SGLT-5 SSA1 ‘B’ 3 dB BW: _24.4_ MHz


SGLT-5 SSA1 ‘A’ 3 dB BW: _24.3_ MHz

Signal Level
Signal Level

3dB BW Marker
3dB BW Marker

36
3/30/07
Signal Level (dBm) Signal Level (dBm)

EC-8412CH1
-25.00
-24.00
-23.00
-22.00
-21.00
-20.00
-19.00
-18.00
-17.00
-25.00
-24.00
-23.00
-22.00
-21.00
-20.00
-19.00
-18.00
-17.00

352,500,000 352,500,000

355,000,000 355,000,000

SSAR-IF System Test Procedure


357,500,000 357,500,000

360,000,000 360,000,000

362,500,000 362,500,000

365,000,000 365,000,000

367,500,000 367,500,000

370,000,000 370,000,000

372,500,000 372,500,000

Frequency (Hz)
Frequency (Hz)
375,000,000 375,000,000

377,500,000 377,500,000

380,000,000 380,000,000
SGLT-5 SSA2A 370 MHz IF 3dB BW

SGLT-5 SSA2B 370 MHz IF 3dB BW


382,500,000 382,500,000

385,000,000 385,000,000

387,500,000 387,500,000

SGLT-5 SSA2 ‘B’ 3 dB BW: _25.9_ MHz


SGLT-5 SSA2 ‘A’ 3 dB BW: _25.1_ MHz

Signal Level
Signal Level

3dB BW Marker
3dB BW Marker

37
SGLT-6 SSA1A 370 MHz IF 3dB BW

-15.00

-16.00

-17.00
Signal Level (dBm)

-18.00

-19.00
Signal Level
-20.00
3dB BW Marker

-21.00

-22.00

-23.00

-24.00

-25.00
352,500,000

355,000,000

357,500,000

360,000,000

362,500,000

365,000,000

367,500,000

370,000,000

372,500,000

375,000,000

377,500,000

380,000,000

382,500,000

385,000,000

387,500,000
Frequency (Hz)

SGLT-6 SSA1 ‘A’ 3 dB BW: _32.0_ MHz

SGLT-6 SSA1B 370 MHz IF 3dB BW

-15.00

-16.00

-17.00
Signal Level (dBm)

-18.00

-19.00
Signal Level
-20.00
3dB BW Marker

-21.00

-22.00

-23.00

-24.00

-25.00
352,500,000

355,000,000

357,500,000

360,000,000

362,500,000

365,000,000

367,500,000

370,000,000

372,500,000

375,000,000

377,500,000

380,000,000

382,500,000

385,000,000

387,500,000

Frequency (Hz)

SGLT-6 SSA1 ‘B’ 3 dB BW: _33.7_ MHz

SSAR-IF System Test Procedure 38


EC-8412CH1
3/30/07
SGLT-6 SSA2A 370 MHz IF 3dB BW

-15.00

-16.00

-17.00
Signal Level (dBm)

-18.00

-19.00
Signal Level
-20.00
3dB BW Marker

-21.00

-22.00

-23.00

-24.00

-25.00
352,500,000

355,000,000

357,500,000

360,000,000

362,500,000

365,000,000

367,500,000

370,000,000

372,500,000

375,000,000

377,500,000

380,000,000

382,500,000

385,000,000

387,500,000
Frequency (Hz)

SGLT-6 SSA2 ‘A’ 3 dB BW: _33.5_ MHz

SGLT-6 SSA2B 370 MHz IF 3dB BW

-16.00

-17.00

-18.00
Signal Level (dBm)

-19.00

-20.00
Signal Level
3dB BW Marker
-21.00

-22.00

-23.00

-24.00

-25.00
352,500,000

355,000,000

357,500,000

360,000,000

362,500,000

365,000,000

367,500,000

370,000,000

372,500,000

375,000,000

377,500,000

380,000,000

382,500,000

385,000,000

387,500,000

390,000,000

Frequency (Hz)

SGLT-6 SSA2 ‘B’ 3 dB BW: _34.8_ MHz

SSAR-IF System Test Procedure 39


EC-8412CH1
3/30/07
4.4 SSAR-IF Infrastructure IF Frequency
The SSAR-IF shall be capable of receiving a 17 MHz Bandwidth SSAR signal at S-band
and frequency translating to 370 MHz IF.

Test Type: Unit/System

Configuration:

SSA1 13307.5 MHz LO


SSA2 13327.5 MHz LO
Mixer
ESG-D3000A IF RF SSA1 or SSA2 370 MHz IF USS IF
Signal
Composite Downconverter 17 MHz BW Switch
Generator
LO Input
LO Monitor
370 MHz (FP)

* FOTS * Fiber * Fiber Fiber Optic * FOTS * Fiber


TX DeMux Amp IFL TX Mux

* Used In SGLTs 1, 2, & 3 Paths Only

370 MHz Frequency


IF Switch
Counter

Procedure:

Configure Signal Generator and RF Mixer per the above drawing; set the signal generator
output level to -19 dBm and a center frequency to 370 MHz.

Connect the HP 5350B Microwave Frequency Counter to the output of the IF Switch.

Record 370 MHz Center Frequency:

SGLT-1 SSA1 ‘A’: _369.999979_ MHz


SGLT-1 SSA1 ‘B’: _369.999980_ MHz
SGLT-1 SSA2 ‘A’: _369.999979_ MHz
SGLT-1 SSA2 ‘B’: _369.999978_ MHz

SGLT-2 SSA1 ‘A’: _370.000042_ MHz


SGLT-2 SSA1 ‘B’: _370.000045_ MHz
SGLT-2 SSA2 ‘A’: _370.000045_ MHz
SGLT-2 SSA2 ‘B’: _370.000047_ MHz

SGLT-3 SSA1 ‘A’: _369.999985_ MHz


SGLT-3 SSA1 ‘B’: _369.999972_ MHz
SGLT-3 SSA2 ‘A’: _369.999972_ MHz
CDS DR 45018 1/4/07 MWO 1083721 SGLT-3 SSA2 ‘B’: _____-_____ MHz
SSAR-IF System Test Procedure 40
EC-8412CH1
3/30/07
SGLT-4 SSA1 ‘A’: _370.000013_ MHz
SGLT-4 SSA1 ‘B’: _370.000018_ MHz
SGLT-4 SSA2 ‘A’: _370.000016_ MHz
SGLT-4 SSA2 ‘B’: _370.000020_ MHz

SGLT-5 SSA1 ‘A’: _370.000020_ MHz


SGLT-5 SSA1 ‘B’: _370.000025_ MHz
SGLT-5 SSA2 ‘A’: _370.000024_ MHz
SGLT-5 SSA2 ‘B’: _370.000024_ MHz

SGLT-6 SSA1 ‘A’: _369.999999_ MHz


SGLT-6 SSA1 ‘B’: _369.999997_ MHz
SGLT-6 SSA2 ‘A’: _369.999999_ MHz
SGLT-6 SSA2 ‘B’: _369.999999_ MHz

4.5 SSAR-IF Infrastructure S-band to IF Processing/IF Output Level


The SSAR-IF shall be capable of routing any 370 MHz SSAR input signal to any of the
thirty-two (32) IF output ports at WTGT or sixteen (16) IF output ports at GRGT while
supplying an IF output level of –15 dBm +/- 3dB.

Test Type: System

Configuration:

SSA1 13307.5 MHz LO


SSA2 13327.5 MHz LO
Mixer
ESG-D3000A IF RF SSA1 or SSA2 370 MHz IF USS IF
Signal
Composite Downconverter 17 MHz BW Switch
Generator
LO Input
LO Monitor
370 MHz (FP)

* FOTS * Fiber * Fiber Fiber Optic * FOTS * Fiber


TX DeMux Amp IFL TX Mux

* Used In SGLTs 1, 2, & 3 Paths Only

370 MHz E4440A


IF Switch Spectrum
Analyzer

Procedure:

SSAR-IF System Test Procedure 41


EC-8412CH1
3/30/07
4.5.1 One-to-One Test
Configure Signal Generator and RF Mixer per the above drawing; set the signal generator
output level to -19 dBm and the center frequency to 370 MHz.

Connect the E4440 Spectrum Analyzer to the output under test of the IF Switch.

Configure the IF Switch to select the configured 370 MHz Downconverter chain and
switch to the straight through output under test.

Record IF Output Level at WSGT.

SGLT-1 SSA1 ‘A’ Input 01 to Output 01: __-17.8___dBm


SGLT-1 SSA1 ‘B’ Input 02 to Output 02: __-17.8___ dBm
SGLT-1 SSA2 ‘A’ Input 03 to Output 03: __-16.9___ dBm
SGLT-1 SSA2 ‘B’ Input 04 to Output 04: __-18.1___ dBm
SGLT-2 SSA1 ‘A’ Input 05 to Output 05: __-16.2___ dBm
SGLT-2 SSA1 ‘B’ Input 06 to Output 06: __-13.4___ dBm
SGLT-2 SSA2 ‘A’ Input 07 to Output 07: __-16.4___ dBm
SGLT-2 SSA2 ‘B’ Input 08 to Output 08: __-15.6___ dBm
SGLT-3 SSA1 ‘A’ Input 09 to Output 09: __-18.1 __ dBm
SGLT-3 SSA1 ‘B’ Input 10 to Output 10: __-16.3___ dBm
SGLT-3 SSA2 ‘A’ Input 11 to Output 11: __-17.4___ dBm
SGLT-3 SSA2 ‘B’ Input 12 to Output 12: ___-_____ dBm
CDS DR 45018 1/4/07 MWO 1083721
SGLT-4 SSA1 ‘A’ Input 13 to Output 13: __-18.7___ dBm
SGLT-4 SSA1 ‘B’ Input 14 to Output 14: __-18.9___ dBm
SGLT-4 SSA2 ‘A’ Input 15 to Output 15: __-18.9___ dBm
SGLT-4 SSA2 ‘B’ Input 16 to Output 16: __-19.7___ dBm
SGLT-5 SSA1 ‘A’ Input 17 to Output 17: __-18.9___ dBm
SGLT-5 SSA1 ‘B’ Input 18 to Output 18: __-18.5___ dBm
SGLT-5 SSA2 ‘A’ Input 19 to Output 19: __-18.9___ dBm
SGLT-5 SSA2 ‘B’ Input 20 to Output 20: __-18.7___ dBm

Record IF Output Level at GRGT.

SGLT-6 SSA1 ‘A’ Input 01 to Output 01: __-16.4___ dBm


SGLT-6 SSA1 ‘B’ Input 02 to Output 02: __-16.7___ dBm
SGLT-6 SSA2 ‘A’ Input 03 to Output 03: __-17.1___ dBm
SGLT-6 SSA2 ‘B’ Input 04 to Output 04: __-17.8___ dBm

4.5.2 One-to-Many Test


Configure Signal Generator and RF Mixer per the above drawing; set the signal generator
output level to -19 dBm and the center frequency to 370 MHz.

SSAR-IF System Test Procedure 42


EC-8412CH1
3/30/07
Connect the E4440 Spectrum Analyzer to the output under test of the IF Switch.

Configure the IF Switch to select the configured 370 MHz Downconverter chain and fan-
out the Switch to all 32 outputs. Record input used.

Record IF Input Used at WSGT:


Input used: __11 (SGLT-3 SSA2A)__ (1-32)

Record IF Output Level at WSGT: Output 01: __-17.8__ dBm


Output 02: __-17.9__ dBm
Output 03: __-17.9__ dBm
Output 04: __-17.5__ dBm
Output 05: __-17.8__ dBm
Output 06: __-17.7__ dBm
Output 07: __-18.4__ dBm
Output 08: __-18.3__ dBm
Output 09: __-17.8__ dBm
Output 10: __-17.7__ dBm
Output 11: __-17.8__ dBm
Output 12: __-17.8__ dBm
Output 13: __-18.2__ dBm
Output 14: __-17.9__ dBm
Output 15: __-17.7__ dBm
Output 16: __-18.3__ dBm
Output 17: __-18.1__ dBm
Output 18: __-17.8__ dBm
Output 19: __-17.7__ dBm
Output 20: __-17.9__ dBm
Output 21: __-18.1_ dBm
Output 22: __-17.8__ dBm
Output 23: __-18.2__ dBm
Output 24: __-17.8__ dBm
Output 25: __-17.7__ dBm
Output 26: __-18.2__ dBm
Output 27: __-17.7__ dBm
Output 28: __-17.8__ dBm
Output 29: __-17.8__ dBm
Output 30: __-17.5__ dBm
Output 31: __-17.7__ dBm
Output 32: __-17.7__ dBm

Record IF Input Used at GRGT:

SSAR-IF System Test Procedure 43


EC-8412CH1
3/30/07
Input used: __03 (SGLT-3 SSA2A)__ (1-16)

Record IF Output Level at GRGT: Output 01: __-16.6__ dBm


Output 02: __-16.7__ dBm
Output 03: __-16.6__ dBm
Output 04: __-16.6__ dBm
Output 05: __-16.7__ dBm
Output 06: __-16.6__ dBm
Output 07: __-16.6__ dBm
Output 08: __-16.6__ dBm
Output 09: __-16.8__ dBm
Output 10: __-16.5__ dBm
Output 11: __-16.6__ dBm
Output 12: __-16.6__ dBm
Output 13: __-16.4__ dBm
Output 14: __-16.6__ dBm
Output 15: __-16.7__ dBm
Output 16: __-16.3__ dBm

SSAR-IF System Test Procedure 44


EC-8412CH1
3/30/07
4.6 SSAR-IF Infrastructure Spurious Outputs
The SSAR-IF shall be capable of providing an IF output where individual spurious signal
are <-40 dBc over 17 MHz about the center frequency and the total spurious signals are
<-30 dBc over the same frequency band as measured at the output of the IF Switch.

Test Type: System

Configuration:

SSA1 13307.5 MHz LO


SSA2 13327.5 MHz LO
Mixer
ESG-D3000A IF RF SSA1 or SSA2 370 MHz IF USS IF
Signal
Composite Downconverter 17 MHz BW Switch
Generator
LO Input
LO Monitor
370 MHz (FP)

* FOTS * Fiber * Fiber Fiber Optic * FOTS * Fiber


TX DeMux Amp IFL TX Mux

* Used In SGLTs 1, 2, & 3 Paths Only

370 MHz E4440A


IF Switch Spectrum
Analyzer

Procedure:
Configure Signal Generator and RF Mixer per the above drawing; set the signal generator
output level to -19 dBm and the center frequency to 370 MHz.

Connect the Agilent E4440A Spectrum Analyzer to the output of the IF Switch.

Send the proper CONNECT command to the IF Switch.

Configure the Agilent E4440A Spectrum Analyzer Measurement function to detect


Spurious Emissions.
- Press the MEASURE button on the spectrum analyzer front panel.
- Tab through the Menu to Spurious Emissions.
- Record data, print and attach to test record.

SSAR-IF System Test Procedure 45


EC-8412CH1
3/30/07
SGLT-1 SSA1 ‘A’ Spurious Signals Completed/Passed _mdh_ (check)

SGLT-1 SSA1 ‘B’ Spurious Signals Completed/Passed _mdh_ (check)

SSAR-IF System Test Procedure 46


EC-8412CH1
3/30/07
SGLT-1 SSA2 ‘A’ Spurious Signals Completed/Passed _mdh_ (check)

SGLT-1 SSA2 ‘B’ Spurious Signals Completed/Passed _mdh_ (check)

SSAR-IF System Test Procedure 47


EC-8412CH1
3/30/07
SGLT-2 SSA1 ‘A’ Spurious Signals Completed/Passed _mdh_ (check)

SGLT-2 SSA1 ‘B’ Spurious Signals Completed/Passed _mdh_ (check)

SSAR-IF System Test Procedure 48


EC-8412CH1
3/30/07
SGLT-2 SSA2 ‘A’ Spurious Signals Completed/Passed _mdh_ (check)

SGLT-2 SSA2 ‘B’ Spurious Signals Completed/Passed _mdh_ (check)

SSAR-IF System Test Procedure 49


EC-8412CH1
3/30/07
SGLT-3 SSA1 ‘A’ Spurious Signals Completed/Passed _mdh_ (check)

SGLT-3 SSA1 ‘B’ Spurious Signals Completed/Passed _mdh_ (check)

SSAR-IF System Test Procedure 50


EC-8412CH1
3/30/07
SGLT-3 SSA2 ‘A’ Spurious Signals Completed/Passed _mdh_ (check)

CDS DR 45018 1/4/07 MWO 1083721

SGLT-3 SSA2 ‘B’ Spurious Signals Completed/Passed __-____ (check)

SSAR-IF System Test Procedure 51


EC-8412CH1
3/30/07
SGLT-4 SSA1 ‘A’ Spurious Signals Completed/Passed _mdh_ (check)

SGLT-4 SSA1 ‘B’ Spurious Signals Completed/Passed _mdh_ (check)

SSAR-IF System Test Procedure 52


EC-8412CH1
3/30/07
SGLT-4 SSA2 ‘A’ Spurious Signals Completed/Passed _mdh_ (check)

SGLT-4 SSA2 ‘B’ Spurious Signals Completed/Passed _mdh_ (check)

SSAR-IF System Test Procedure 53


EC-8412CH1
3/30/07
SGLT-5 SSA1 ‘A’ Spurious Signals Completed/Passed _mdh_ (check)

SGLT-5 SSA1 ‘B’ Spurious Signals Completed/Passed _mdh_ (check)

SSAR-IF System Test Procedure 54


EC-8412CH1
3/30/07
SGLT-5 SSA2 ‘A’ Spurious Signals Completed/Passed _mdh_ (check)

SGLT-5 SSA2 ‘B’ Spurious Signals Completed/Passed _mdh_ (check)

SSAR-IF System Test Procedure 55


EC-8412CH1
3/30/07
SGLT-6 SSA1 ‘A’ Spurious Signals Completed/Passed _kk_ (check)

SGLT-6 SSA1 ‘B’ Spurious Signals Completed/Passed _kk_ (check)

SSAR-IF System Test Procedure 56


EC-8412CH1
3/30/07
SGLT-6 SSA2 ‘A’ Spurious Signals Completed/Passed _kk_ (check)

SGLT-6 SSA2 ‘B’ Spurious Signals Completed/Passed _kk_ (check)

SSAR-IF System Test Procedure 57


EC-8412CH1
3/30/07
4.7 SSAR-IF Infrastructure AM/PM
The SSAR-IF shall be capable of providing an IF output where AM/PM ≤ 0.5o/dB
measured at the IF output port of the IF Switch. Contributions from only the S-band
Infrastructure are included.

Test Type: System

Configuration for SGLTs 4/5/6:

370 MHz

IF Network
Analyzer
RF SSA1 or SSA2 USS IF IF
Mixer
Composite Downconverter Switch Switch
370 MHz
LO Input
LO Monitor 370 MHz CW
(FP)
Power Sweep
SSA1 13307.5 MHz LO
-20 dBm to -10 dBm
SSA2 13327.5 MHz LO

Procedure:
Connect the test equipment as shown in the diagram above.

Calibrate the through ports of the network analyzer with the test cables that will be used.
Connect the IF port of the test mixer to the output of the network analyzer. Set the 2-port
network analyzer to CW mode at 370 MHz with a power sweep from –20 dBm to –10
dBm. Set the sweep time to 10 seconds. Connect the LO port of the test mixer to the front
panel LO Monitor point of the downconverter. Connect the output of the test mixer to the
input of the downconverter. Connect the output of the IF Switch to the receiving port of
the network analyzer. Set the network analyzer to measure the phase change between the
power sweep points. Measure the change in relative phase change between the power
sweep points on the network analyzer. Divide the reading by 10 and record the relative
change:

SSAR-IF System Test Procedure 58


EC-8412CH1
3/30/07
SGTLT-4 SSA1A
SSAR-IF AM/PM Conversion

2.5

2
Phase (° Degrees)

1.5

0.5

0
-20 -19 -18 -17 -16 -15 -14 -13 -12 -11 -10
Signal Level (dBm)

SGLT-4 SSA1 ‘A’ AM/PM Conversion: _0.20_ o/dB

SGTLT-4 SSA1B
SSAR-IF AM/PM Conversion

2.5

2
Phase (° Degrees)

1.5

0.5

0
-20 -19 -18 -17 -16 -15 -14 -13 -12 -11 -10
Signal Level (dBm)

SGLT-4 SSA1 ‘B’ AM/PM Conversion: _0.16_ o/dB

SSAR-IF System Test Procedure 59


EC-8412CH1
3/30/07
SGTLT-4 SSA2A
SSAR-IF AM/PM Conversion

2.5

2
Phase (° Degrees)

1.5

0.5

0
-20 -19 -18 -17 -16 -15 -14 -13 -12 -11 -10
Signal Level (dBm)

SGLT-4 SSA2 ‘A’ AM/PM Conversion: _0.08_ o/dB

SGTLT-4 SSA2B
SSAR-IF AM/PM Conversion

2.5

2
Phase (° Degrees)

1.5

0.5

0
-20 -19 -18 -17 -16 -15 -14 -13 -12 -11 -10
Signal Level (dBm)

SGLT-4 SSA2 ‘B’ AM/PM Conversion: _0.20_ o/dB

SSAR-IF System Test Procedure 60


EC-8412CH1
3/30/07
SGTLT-5 SSA1A
SSAR-IF AM/PM Conversion

2.5

2
Phase (° Degrees)

1.5

0.5

0
-20 -19 -18 -17 -16 -15 -14 -13 -12 -11 -10
Signal Level (dBm)

SGLT-5 SSA1 ‘A’ AM/PM Conversion: _0.18_ o/dB

SGTLT-5 SSA1B
SSAR-IF AM/PM Conversion

2.5

2
Phase (° Degrees)

1.5

0.5

0
-20 -19 -18 -17 -16 -15 -14 -13 -12 -11 -10
Signal Level (dBm)

SGLT-5 SSA1 ‘B’ AM/PM Conversion: _0.12_ o/dB

SSAR-IF System Test Procedure 61


EC-8412CH1
3/30/07
SGTLT-5 SSA2A
SSAR-IF AM/PM Conversion

2.5

2
Phase (° Degrees)

1.5

0.5

0
-20 -19 -18 -17 -16 -15 -14 -13 -12 -11 -10
Signal Level (dBm)

SGLT-5 SSA2 ‘A’ AM/PM Conversion: _0.12_ o/dB

SGTLT-5 SSA2B
SSAR-IF AM/PM Conversion

2.5

2
Phase (° Degrees)

1.5

0.5

0
-20 -19 -18 -17 -16 -15 -14 -13 -12 -11 -10
Signal Level (dBm)

SGLT-5 SSA2 ‘B’ AM/PM Conversion: _0.14_ o/dB

Note:
AM/PM Conversion Plots for
SGLT-6 are not available.

SSAR-IF System Test Procedure 62


EC-8412CH1
3/30/07
SGLT-6 SSA1 ‘A’ AM/PM Conversion: _0.18_ o/dB
SGLT-6 SSA1 ‘B’ AM/PM Conversion: _0.25_ o/dB
SGLT-6 SSA2 ‘A’ AM/PM Conversion: _0.25_ o/dB
SGLT-6 SSA2 ‘B’ AM/PM Conversion: _0.05_ o/dB

AM/PM testing requires the test configuration to serve as a source and sink for the test
signal. For SGLT-1/2/3 testing, the SGLT-4 equipment was used, routed through a short-
loop FOTS path, then through the IF Switch port. The configuration is illustrated in the
figure below:

Configuration for SGLTs 1/2/3 Simulated:

370 MHz

IF Network
Analyzer
RF SSA1 or SSA2 USS IF IF
Mixer
Composite Downconverter Switch Switch
370 MHz
LO Input
LO Monitor 370 MHz CW
(FP)
Power Sweep
SSA1 13307.5 MHz LO
-20 dBm to -10 dBm
SSA2 13327.5 MHz LO

FOTS Fiber FOTS


TX Amp RCV

SGTLT-4 SSA1A
SSAR-IF AM/PM Conversion with FOTS

2.5

2
Phase (° Degrees)

1.5

0.5

0
-20 -19 -18 -17 -16 -15 -14 -13 -12 -11 -10
Signal Level (dBm)

Simulated SGLT-1/2/3 AM/PM Conversion: _0.16_ o/dB

SSAR-IF System Test Procedure 63


EC-8412CH1
3/30/07
4.8 SSAR-IF Infrastructure Noise Figure
The SSAR-IF shall be capable of providing an IF signal with a noise figure of ≤19 dB as
measured at the output of the IF Switch.

Test Type: Unit/System

Basic Test Configuration:


The Basic test configuration will measure the noise figure of the IF Switch and FOTS.

HP8970B HP346B
Noise Figure Meter OUT Noise Source

IN

UUT

Procedure:

The HP8970B Noise Meter must be calibrated before any reading can be performed.

NOTE: This procedure will measure Noise Figures expected to be less than 30 dB

Configure the HP8970B Noise Figure test set according the to following figure.

HP8970B HP346B
Noise Figure Meter OUT Noise Source

IN

HP8970B Measurement Mode 1.0 Calibration Setup

Configure the HP 8970B Noise Figure Meter according to the diagram and configure the
chassis per ME-13659 Measurement Mode 1.0.

Set Frequency to 370 MHz (measure IF)

Press the CALIBRATE button twice. When the calibration is complete the HP8970B
Noise Figure Meter will default to the CORRECTED NOISE FIGURE AND GAIN mode.

SSAR-IF System Test Procedure 64


EC-8412CH1
3/30/07
4.8.1 FOTS Noise Figure
It is required to measure the noise figure of the IFL FOTS. This will be accomplished
with the system on the bench due to the fiber optic mux, demux, FOTS, and amplifier
being located separately in the system.

NOTE: In-house testing revealed the length of the fiber optic cable did not affect the
value of the noise figure reading (7 miles fiber vs. back-to-back).

Connect the HP8970B Noise Figure Meter to the FOTS unit per the following diagram:

HP8970B HP346B
Noise Figure Meter Noise Source
OUT

IN

FOTS F/O F/O F/O FOTS


RCV DMUX AMP MUX TX

FOTS Rack

FOTS System Noise Figure Measurement using the HP8970B

Record the measured value for the Noise Figure (NF) for the FOTS unit:

(SGLT-1 SSA1 “A”, Switch Input 01) Channel 22 Noise Figure: _20.1_dB
(SGLT-1 SSA1 “B”, Switch Input 02) Channel 23 Noise Figure: _21.2_dB
(SGLT-1 SSA2 “A”, Switch Input 03) Channel 24 Noise Figure: _22.5_dB
(SGLT-1 SSA2 “B”, Switch Input 04) Channel 25 Noise Figure: _22.5_dB
(SGLT-2 SSA1 “A”, Switch Input 05) Channel 26 Noise Figure: _22.6_dB
(SGLT-2 SSA1 “B”, Switch Input 06) Channel 27 Noise Figure: _21.7_dB
(SGLT-2 SSA2 “A”, Switch Input 07) Channel 28 Noise Figure: _21.3_dB
(SGLT-2 SSA2 “B”, Switch Input 08) Channel 29 Noise Figure: _20.1_dB
(SGLT-3 SSA1 “A”, Switch Input 09) Channel 30 Noise Figure: _20.9_dB
(SGLT-3 SSA1 “B”, Switch Input 10) Channel 31 Noise Figure: _22.5_dB
(SGLT-3 SSA2 “A”, Switch Input 11) Channel 32 Noise Figure: _23.3_dB
(SGLT-3 SSA2 “B”, Switch Input 12) Channel 33 Noise Figure: _23.4_dB
(SPARE, Switch Input N/C) Channel 34 Noise Figure: _21.1_dB
(SPARE, Switch Input N/C) Channel 35 Noise Figure: _21.3_dB

4.8.2 IF Switch Noise Figure


Configure the HP8970B Noise Figure meter to measure the noise figure on the IF Switch
per the diagram above.

SSAR-IF System Test Procedure 65


EC-8412CH1
3/30/07
Configure the IF Switch with the following switch connections.

Record Noise Figure for WSGT 32x32 IF Switch:


Input 01 to Output 01: _14.7_ dB
Input 02 to Output 02: _14.6_ dB
Input 03 to Output 03: _14.6_ dB
Input 04 to Output 04: _14.6_ dB
Input 05 to Output 05: _14.7_ dB
Input 06 to Output 06: _14.8_ dB
Input 07 to Output 07: _14.6_ dB
Input 08 to Output 08: _14.6_ dB
Input 09 to Output 09: _14.6_ dB
Input 10 to Output 10: _14.6_ dB
Input 11 to Output 11: _14.8_ dB
Input 12 to Output 12: _14.7_ dB
Input 13 to Output 13: _14.6_ dB
Input 14 to Output 14: _14.7_ dB
Input 15 to Output 15: _14.7_ dB
Input 16 to Output 16: _14.7_ dB
Input 17 to Output 17: _14.6_ dB
Input 18 to Output 18: _14.8_ dB
Input 19 to Output 19: _14.6_ dB
Input 20 to Output 20: _14.6_ dB
Input 21 to Output 21: _14.6_ dB
Input 22 to Output 22: _14.6_ dB
Input 23 to Output 23: _14.8_ dB
Input 24 to Output 24: _14.7_ dB
Input 25 to Output 25: _14.6_ dB
Input 26 to Output 26: _14.7_ dB
Input 27 to Output 27: _14.8_ dB
Input 28 to Output 28: _14.6_ dB
Input 29 to Output 29: _14.6_ dB
Input 30 to Output 30: _14.7_ dB
Input 31 to Output 31: _14.6_ dB
Input 32 to Output 32: _14.6_ dB

Record Noise Figure for GRGT 16x16 IF Switch:


Input 01 to Output 01: _14.6_ dB
Input 02 to Output 02: _14.7_ dB
Input 03 to Output 03: _14.7_ dB
Input 04 to Output 04: _14.8_ dB
Input 05 to Output 05: _14.6_ dB
Input 06 to Output 06: _14.6_ dB
Input 07 to Output 07: _14.6_ dB
Input 08 to Output 08: _14.6_ dB
Input 09 to Output 09: _14.6_ dB

SSAR-IF System Test Procedure 66


EC-8412CH1
3/30/07
Input 10 to Output 10: _14.7_ dB
Input 11 to Output 11: _14.6_ dB
Input 12 to Output 12: _14.6_ dB
Input 13 to Output 13: _14.8_ dB
Input 14 to Output 14: _14.7_ dB
Input 15 to Output 15: _14.6_ dB
Input 16 to Output 16: _14.7_ dB

4.8.3 Cable Passive Noise Figure


Cable Noise figure is equivalent to the attenuation in the cables at the mid-band (370
MHz) frequency. In-house testing revealed that the Andrew equation for their cable is
extremely accurate. The following cable Noise Figures were calculated. (100’ for STGT,
90’ for WSGT, 65’ for GRGT)

SGLT-1 SSA1 “A” Cable Noise Figure: _1.41_ dB


SGLT-1 SSA1 “B” Cable Noise Figure: _1.41_ dB
SGLT-1 SSA2 “A” Cable Noise Figure: _1.41_ dB
SGLT-1 SSA2 “B” Cable Noise Figure: _1.41_ dB

SGLT-2 SSA1 “A” Cable Noise Figure: _1.41_ dB


SGLT-2 SSA1 “B” Cable Noise Figure: _1.41_ dB
SGLT-2 SSA2 “A” Cable Noise Figure: _1.41_ dB
SGLT-2 SSA2 “B” Cable Noise Figure: _1.41_ dB

SGLT-3 SSA1 “A” Cable Noise Figure: _1.41_ dB


SGLT-3 SSA1 “B” Cable Noise Figure: _1.41_ dB
SGLT-3 SSA2 “A” Cable Noise Figure: _1.41_ dB
SGLT-3 SSA2 “B” Cable Noise Figure: _1.41_ dB

SGLT-4 SSA1 “A” Cable Noise Figure: _1.27_ dB


SGLT-4 SSA1 “B” Cable Noise Figure: _1.27_ dB
SGLT-4 SSA2 “A” Cable Noise Figure: _1.27_ dB
SGLT-4 SSA2 “B” Cable Noise Figure: _1.27_ dB

SGLT-5 SSA1 “A” Cable Noise Figure: _1.27_ dB


SGLT-5 SSA1 “B” Cable Noise Figure: _1.27_ dB
SGLT-5 SSA2 “A” Cable Noise Figure: _1.27_ dB
SGLT-5 SSA2 “B” Cable Noise Figure: _1.27_ dB

SGLT-6 SSA1 “A” Cable Noise Figure: _0.92_ dB


SGLT-6 SSA1 “B” Cable Noise Figure: _0.92_ dB
SGLT-6 SSA2 “A” Cable Noise Figure: _0.92_ dB
SGLT-6 SSA2 “B” Cable Noise Figure: _0.92_ dB

SSAR-IF System Test Procedure 67


EC-8412CH1
3/30/07
4.8.4 System Total Noise Figure
The following formula will be used to compute the total system Noise Figure for the
WSC SSAR-IF Infrastructure where the Noise Figure (F) and Gain (G) are linear ratios:

Note: SGLTs 1, 2, and 3 total noise figures will be comprised of the contributions of the
SSAR Downconverter (approximated at NF=15dB, G=20dB), SSAR SSA/KSA IF
Switch Coupler (insertion loss at 2dB), cables (at 370 MHz), Fiber Optic Transceiver
(G=20dB), and the straight-through path of the IF switch (G=0dB).

SGLT-1 SSA1 “A” Total Noise Figure: _15.3_ dB


SGLT-1 SSA1 “B” Total Noise Figure: _15.4_ dB
SGLT-1 SSA2 “A” Total Noise Figure: _15.5_ dB
SGLT-1 SSA2 “B” Total Noise Figure: _15.5_ dB

SGLT-2 SSA1 “A” Total Noise Figure: _15.5_ dB


SGLT-2 SSA1 “B” Total Noise Figure: _15.4_ dB
SGLT-2 SSA2 “A” Total Noise Figure: _15.4_ dB
SGLT-2 SSA2 “B” Total Noise Figure: _15.3_ dB

SGLT-3 SSA1 “A” Total Noise Figure: _15.4_ dB


SGLT-3 SSA1 “B” Total Noise Figure: _15.5_ dB
SGLT-3 SSA2 “A” Total Noise Figure: _15.6_ dB
SGLT-3 SSA2 “B” Total Noise Figure: _15.6_ dB

Note: SGLTs 4, 5, and 6 total noise figures will be comprised of the contributions of the
SSAR Downconverter (approximated at NF=15dB, G=20dB), SSA/KSA IF Switch
Coupler (insertion loss of 2dB), cables (at 370 MHz), and the straight-through path of the
IF switch (G=0dB).

SGLT-4 SSA1 “A” Total Noise Figure: _15.1_ dB


SGLT-4 SSA1 “B” Total Noise Figure: _15.1_ dB
SGLT-4 SSA2 “A” Total Noise Figure: _15.1_ dB
SGLT-4 SSA2 “B” Total Noise Figure: _15.1_ dB

SGLT-5 SSA1 “A” Total Noise Figure: _15.1_ dB


SGLT-5 SSA1 “B” Total Noise Figure: _15.1_ dB
SGLT-5 SSA2 “A” Total Noise Figure: _15.1_ dB
SGLT-5 SSA2 “B” Total Noise Figure: _15.1_ dB
SSAR-IF System Test Procedure 68
EC-8412CH1
3/30/07
SGLT-6 SSA1 “A” Total Noise Figure: _15.1_ dB
SGLT-6 SSA1 “B” Total Noise Figure: _15.1_ dB
SGLT-6 SSA2 “A” Total Noise Figure: _15.1_ dB
SGLT-6 SSA2 “B” Total Noise Figure: _15.1_ dB

4.9 SSAR-IF Output VSWR


The SSAR-IF output shall have an output VSWR less than or equal to 1.3:1 as measured
at the IF output port.

Test Type: Unit/System

Note:
This is verified in vendor testing at the unit level but
is also checked in the SSAR-IF infrastructure.

Configuration:

HP83620A
Signal Generator
Wiltron
60NF50 OUTPUT
IF Switch
SWR
Bridge
E4440A
Spectrum Analyzer

Procedure:
Configure the test setup per the figure above. Set the HP83620A signal generator to a
center frequency of 370 MHz, -15 dBm and a bandwidth of 17 MHz. Set sweep time to 1
second. Connect a short circuit (HP85052-60006 or similar) in place of the IF Switch. Set
the E4440A spectrum analyzer to 370 MHz and a span of 17 MHz, with MAX HOLD
enabled. Record the minimum value across the band. Connect the VSWR Bridge to the
output of the IF Switch.

Configure the IF switch so that input 1 is connected to output 1, input 2 to output 2, etc.

Connect the VSWR Bridge to the IF Switch. With MAX HOLD enabled, measure the
maximum signal level. Compute the delta between the maximum signal level and
minimum signal level to determine return loss. Use the following formula to compute
VSWR:

RL = max signal level – minimum signal level

SSAR-IF System Test Procedure 69


EC-8412CH1
3/30/07
VSWR = ( 1+ (10RL/20)) / (10RL/20) – 1
(20060606)
WSGT 32x32 IF Switch:
Output 01 VSWR: _1.06_
Output 02 VSWR: _1.10_
Output 03 VSWR: _1.08_
Output 04 VSWR: _1.10_
Output 05 VSWR: _1.06_
Output 06 VSWR: _1.06_
Output 07 VSWR: _1.07_
Output 08 VSWR: _1.05_
Output 09 VSWR: _1.04_
Output 10 VSWR: _1.05_
Output 11 VSWR: _1.03_
Output 12 VSWR: _1.08_
Output 13 VSWR: _1.12_
Output 14 VSWR: _1.09_
Output 15 VSWR: _1.08_
Output 16 VSWR: _1.08_
Output 17 VSWR: _1.06_
Output 18 VSWR: _1.09_
Output 19 VSWR: _1.10_
Output 20 VSWR: _1.10_
Output 21 VSWR: _1.14_
Output 22 VSWR: _1.08_
Output 23 VSWR: _1.07_
Output 24 VSWR: _1.07_
Output 25 VSWR: _1.05_
Output 26 VSWR: _1.07_
Output 27 VSWR: _1.06_
Output 28 VSWR: _1.13_
Output 29 VSWR: _1.05_
Output 30 VSWR: _1.10_
Output 31 VSWR: _1.07_
Output 32 VSWR: _1.05_

GRGT 16x16 IF Switch:


Output 01 VSWR: _1.22_
Output 02 VSWR: _1.28_
Output 03 VSWR: _1.23_
Output 04 VSWR: _1.26_
Output 05 VSWR: _1.17_
Output 06 VSWR: _1.16_
Output 07 VSWR: _1.18_
Output 08 VSWR: _1.18_
Output 09 VSWR: _1.16_
SSAR-IF System Test Procedure 70
EC-8412CH1
3/30/07
Output 10 VSWR: _1.22_
Output 11 VSWR: _1.16_
Output 12 VSWR: _1.18_
Output 13 VSWR: _1.23_
Output 14 VSWR: _1.22_
Output 15 VSWR: _1.23_
Output 16 VSWR: _1.27_

5. CONTROL AND MONITOR CRITERIA


The control and monitor portion of the SSAR-IF System Test procedure ensures that the
SSAR-IF Infrastructure meets the design. The philosophy of this test procedure is to
thoroughly test on SGLT control and status on one WSC SGLT while running a limited
test set on the remaining SGLTs. The rationale for this decision is the SGLTs run
identical software and running a thorough test on all SGLTs is redundant.

Section 5.1 of this procedure tests the ability to control and status the 370 MHz SSAR-IF
Infrastructure and demonstrates the ability to detect fault isolation and failover.

Sections 5.2 and 5.3 of this procedure test the ability to control and status the SSAR-IF
Switch both from the TOCC and locally from the front panel.

Section 5.4 details in-house testing of the STGT IF Switch Controller (SISC) while
receiving commands and reporting status to the Sub-system Controllers at the STGT and
WSGT.

5.1 SSAR-IF Infrastructure Fault Detection –IF Switch


The SSAR-IF shall be capable of automatically configuring equipment for customer
support in response to SHO’s and OPM’s. The 370 MHz IF signal must be routed to the
customer IF output port at the IF Switch. The SSAR-IF Infrastructure shall be capable of
monitoring key equipment parameters, both locally and remotely, and detect equipment
failures.

Test Type: System

Procedure:

NOTE: This test will be performed on only one SGLT.

Enter an End-to-End SHO either from the Canned SHO Editor or from the WSC
NCCDS.

SSAR-IF System Test Procedure 71


EC-8412CH1
3/30/07
Run Test SHO and monitor the status of the IF Switch.

Verify proper status (signal presence) using the displays GT_T_CTF22, GT_T_CTF23,
and GT_T_CTF26.
Verify: _mdh_

To simulate a fault, disconnect the RF Signal from Downconverter ‘A’ or the inline path.
Verify fault isolation and failover capability to Downconverter ‘B’.

Record SGLT used: __SGLT-1 (1/11/07)___

Verify fault detection/failover: __mdh__Failed (CDS 45073)_

5.2 SSAR-IF Infrastructure TOCC Control and Monitor


The SSAR-IF shall be capable of being controlled and monitored manually from the
TOCC.

Test Type: System

Configuration:

Procedure: See each below

5.2.1 WSGT IF Switch Control and Status (from STGT)


The current capabilities of the IF Switch allow for a single input to be connected to a
single output. To fan out to several outputs, each connection must be made individually.
The WSC IF Switch software does not currently allow a “disconnect all” function.

Toggle the IF Switch between the REMOTE and LOCAL modes using the WIFRRMLC
command. Leave chassis in the REMOTE mode for the remainder of the test.

Remote/Local (RL) Verify: _mdh_

Send the following series of commands to the IF Switch manually from the TOCC:

Make a switch connection using the WIFRCITO command:

Switch Close (SC) Verify: _mdh_

Break the switch connection made in the previous step using the WIFRDITO command:

Switch Open (SO) Verify: _mdh_

SSAR-IF System Test Procedure 72


EC-8412CH1
3/30/07
Collect the following status using the following displays from the IF Switch:
GT_T_CTF21 SSAR IF Switch Status

Internal Battery Verify: _mdh_


+5V #1 Verify: _mdh_
+5V #2 Verify: _mdh_
+12V #1 Verify: _mdh_
+12V #2 Verify: _mdh_
-5V #1 Verify: _mdh_
-5V #2 Verify: _mdh_
Local/Remote Mode Verify: _mdh_

Use the following displays to check other pertinent IF Switch related status:
Displays GT_T_CTF22…23

Output port connections and signal presence Verify: _mdh_

Apply and remove a signal source at the input of the IF Switch to verify proper status
(Approximate trip level: -30 dBm):
Verify: _mdh_

GT_T_CTF13 IF Switch Controller Status

Ka Switch Interface Healthy


SSAR IF Switch Interface Healthy “Side A Data”
WSGT SSC A Interface Healthy
WSGT SSC B Interface Healthy
STGT SSA A Interface Healthy
STGT SSC B Interface Healthy
Switch Controller P/S State Healthy
Switch Controller Fan State Healthy

Verify Proper Status of SSARIF Switch Verify: __mdh_Failed (CDS 45060)_

GT_T_CTF24 SSAR IF Switch SSC Status

Proper Status Verify: _mdh_

SSAR-IF System Test Procedure 73


EC-8412CH1
3/30/07
5.2.2 WSGT IF Switch Control and Status (from WSGT)
The current capabilities of the IF Switch allow for a single input to be connected to a
single output. To fan out to several outputs, each connection must be made individually.
The WSC IF Switch software does not currently allow a “disconnect all” function.

Toggle the IF Switch between the REMOTE and LOCAL modes using the WIFRRMLC
command. Leave chassis in the REMOTE mode for the remainder of the test.

Remote/Local (RL) Verify: _mdh_

Send the following series of commands to the IF Switch manually from the TOCC:

Make a switch connection using the WIFRCITO command:

Switch Close (SC) Verify: _mdh_

Break the switch connection made in the previous step using the WIFRDITO command:

Switch Open (SO) Verify: _mdh_

Collect the following status using the following displays from the IF Switch:
GT_T_CTF21 SSAR IF Switch Status

Internal Battery Verify: _mdh_


+5V #1 Verify: _mdh_
+5V #2 Verify: _mdh_
+12V #1 Verify: _mdh_
+12V #2 Verify: _mdh_
-5V #1 Verify: _mdh_
-5V #2 Verify: _mdh_
Local/Remote Mode Verify: _mdh_

Use the following displays to check other pertinent IF Switch related status:
Displays GT_T_CTF22…23

Output port connections and signal presence Verify: _mdh_

Apply and remove a signal source at the input of the IF Switch to verify proper status
(approximate trip level: -30 dBm).

GT_T_CTF13 IF Switch Controller Status

SSAR-IF System Test Procedure 74


EC-8412CH1
3/30/07
Ka Switch Interface Healthy
SSAR Switch Interface Healthy “Side A Data”
WSGT SSC A Interface Healthy
WSGT SSC B Interface Healthy
STGT SSA A Interface Healthy
STGT SSC B Interface Healthy
Switch Controller P/S State Healthy
Switch Controller Fan State Healthy

Verify Proper Status of SSAR IF Switch Verify: _mdh Failed (CDS 45060)__

GT_T_CTF24 SSAR IF Switch SSC Status

Proper Status Verify: _mdh_

5.2.3 GRGT IF Switch Control and Status (from WSGT)


The current capabilities of the IF Switch allow for a single input to be connected to a
single output. To fan out to several outputs, each connection must be made individually.
The WSC IF Switch software does not currently allow a “disconnect all” function.

Toggle the IF Switch between the REMOTE and LOCAL modes using the GIFRRMLC
command. Leave chassis in the REMOTE mode for the remainder of the test.

Remote/Local (RL) Verify: _mdh_

Send the following series of commands to the IF Switch manually from the TOCC:

Make a switch connection using the GIFRCITO command:

Switch Close (SC) Verify: _mdh_

Break the switch connection made in the previous step using the GIFRDITO command:

Switch Open (SO) Verify: _mdh_

Collect the following status using the following displays from the IF Switch:
GT_T_CTF25 SSAR IF Switch Status

Internal Battery Verify: _mdh_


+5V #1 Verify: _mdh_
+5V #2 Verify: _mdh_
+12V #1 Verify: _mdh_

SSAR-IF System Test Procedure 75


EC-8412CH1
3/30/07
+12V #2 Verify: _mdh_
-5V #1 Verify: _mdh_
-5V #2 Verify: _mdh_
Local/Remote Mode Verify: _mdh_

Use the following displays to check other pertinent IF Switch related status:
Display GT_T_CTF26

Output port connections and signal presence Verify: _mdh_

Apply and remove a signal source at the input of the IF Switch to verify proper status
(Approximate trip level: -30 dBm):
Verify: _mdh_

GT_T_CTF27 SSAR IF Switch SSC Status

Proper Status Verify: _mdh_

5.3 SSAR-IF Infrastructure Control and Monitor – Local


The SSAR-IF shall be capable of being controlled and monitored locally from the chassis
front panel or controller.

Test Type: System

Procedure: See each below

5.3.1 WSGT IF Switch Local Control and Status


To verify manual operation of the IF switch from the front panel, perform the following
functions:

Perform a connect function by pressing the OUT button, followed by the selected output
port number, then the IN button and the selected input port number, and then the ENT
button. Verify connection is made.

Verify Front Panel Connection: _mdh_

Verify an IF signal is present at the specified input. Verify that signal presence is
indicated by a “P” on the front panel.

Verify Signal Presence: _mdh_

SSAR-IF System Test Procedure 76


EC-8412CH1
3/30/07
Switch one of the power supplies to the OFF condition. Verify the RED fault indicator is
illuminated.

Verify Fault Indication: _mdh_

Perform a disconnect function by pressing the IN button, followed by the input port
number and OFF.

Verify Input display shows “ - -“: _mdh_

5.3.2 GRGT IF Switch Local Control and Status


To verify manual operation of the IF switch from the front panel, perform the following
functions:

Perform a connect function by pressing the OUT button, followed by the selected output
port number, then the IN button and the selected input port number, and then the ENT
button. Verify connection is made.

Verify Front Panel Connection: _mdh_

Verify an IF signal is present at the specified input. Verify that signal presence is
indicated by a “P” on the front panel.

Verify Signal Presence: _mdh_

Switch one of the power supplies to the OFF condition. Verify the RED fault indicator is
illuminated.

Verify Fault Indication: _mdh_

Perform a disconnect function by pressing the IN button, followed by the input port
number and OFF.

Verify Input display shows “ - -“: _mdh_

5.4 WSGT IF Switch Control via Multiple ADPE’s.


The STGT IF Switch Controller (SISC) chassis is a WSC-developed chassis that serves
as an arbiter function among the four Sub-system Controllers (SSC’s) capable of
commanding the IF Switch.

Test Type: System

Configuration:

SSAR-IF System Test Procedure 77


EC-8412CH1
3/30/07
STGT DIS STGT DIS
ADPE-A ADPE-B

STGT CTFS STGT CTFS


SSC-A SSC-B Ka IF Switch
(Existing)

STGT IF Switch Controller


(SISC)

RS-422 RS-422

Low Speed FOTS


Ch.7 Ch.8 Ch.9
STGT

WSGT
Ch.7 Ch.8 Ch.9
Low Speed FOTS

RS-422 RS-422

SSAR IF
WSGT CTFS WSGT CTFS Switch
SSC-A SSC-B 32x32

WSGT DIS WSGT DIS


ADPE-A ADPE-B

RS-422
Auto-Switch
RS-422

WSGT GDIS
MM+ Ch.7
WSGT

GRGT
GRGT GDIS
MM+ Ch.7

GLISC
RS-422
SSAR IF
w/ IF Switch Switch
Controller 16x16
Function

SSAR-IF Control & Status

SSAR-IF System Test Procedure 78


EC-8412CH1
3/30/07
Procedure:

5.4.1 WSGT/STGT Staggered Control of the IF Switch


Ensure and verify no switch connections are currently made through the IF Switch
matrix. Set the IF Switch chassis to the REMOTE mode, and have OPS turn status on.

Record date and time of test:


Date/time of test: _23-Jan-07 (2007023/1615z)_

Coordinate staggered commands from WSGT and STGT. Initial commands should
consist of CONNECT (CITO) commands. Verify at the IF Switch front panel switch
connections were made.

Staggered CITO Commands verified at IF Switch front panel: _mdh_

Coordinate staggered commands from WSGT and STGT. Initial commands should
consist of DISCONNECT (DITO) commands. Verify at the IF Switch front panel switch
connections were broken.

Staggered DITO Commands verified at IF Switch front panel: _mdh_

5.4.2 WSGT/STGT Simultaneous Control of the 32x32 IF Switch


Ensure and verify no switch connections are currently made through the IF Switch
matrix. Set the IF Switch chassis to the REMOTE mode, and have OPS turn status on.
Simultaneous commands to the STGT IF Switch will be sent from the WSGT CTFS SSC
and the STGT CTFS SSC via a “timed” command available from the DIS ADPE.

Record date and time of test:


Date/time of test: _23-Jan-07 (2007023/1625z)_

Set IF Switch “time bomb” commands to occur simultaneously at WSGT and STGT.
Initial commands should consist of CONNECT (CITO) commands. Verify at the IF
Switch front panel switch connections were made.

Simultaneous CITO Commands verified at IF Switch front panel: _mdh_

Set IF Switch “timed” commands to occur simultaneously at WSGT and STGT. Initial
commands should consist of DISCONNECT (DITO) commands. Verify at the IF Switch
front panel switch connections were broken.

Simultaneous DITO Commands verified at IF Switch front panel: _mdh_

SSAR-IF System Test Procedure 79


EC-8412CH1
3/30/07
6. TEST EQUIPMENT CALIBRATION LIST

Model Instrument NENS Tag No. Cal Date Due Date


ESG-D3000A Signal Generator G74399 03-22-05 03-22-07
E4407B Spectrum Analyzer G08631 03-22-06 03-22-07
E4432B Signal Generator G74858 09-18-05 09-18-07
E4440A Spectrum Analyzer G04782 07-07-06 07-07-07
ESG-D3000A Signal Generator G02888 01-14-05 01-14-07
E4440A Spectrum Analyzer G06434 04-18-06 04-18-07
E4407B Spectrum Analyzer G07989 01-25-06 01-25-07
HP8970B Noise Figure Meter G74354 04-01-05 10-01-06
HP5342A Frequency Counter G74427 03-22-06 09-22-07
ESG-D3000A Signal Generator G74573 08-17-06 08-17-07
HP8752A Network Analyzer G74357 10-14-06 10-14-07
E4440A Spectrum Analyzer G74575 08-23-06 08-23-07
MF2412B Frequency Counter G70743 07-16-06 01-16-08

SSAR-IF System Test Procedure 80


EC-8412CH1
3/30/07
7. CUSTOMER VALIDATION OF REQUIREMENTS

An S-Band return 370MHz Intermediate Frequency (IF) signal from SGLTs 1, 2, 3, 4, 5,


& 6, USS SSA A&B chains will be supplied from demarcations located at White Sands
Ground Terminal (WSGT) and Guam Remote Ground Terminal (GRGT). The system
will meet the requirements specified within this document.

Customer Validation Date

SSAR-IF System Test Procedure 81


EC-8412CH1
3/30/07