REVISIONS

BY

2 TACTILE EXIT SIGNS


FOR THE PURPOSES OF SECTION 101 1.3, THE TERM "TACTILE EXIT SIGNS" SHALL MEAN THOSE REQUIRED SIGNS THAT COMPLY WITH SECTION 11 17B.5.1, ITEM I. TACTILE EXIT SIGNS SHALL BE REQUIRED AT THE FOLLOWING LOCATIONS: EACH GRADE-LEVEL EXTERIOR EXIT DOOR SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE WORD, "EXIT." EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVEL EXTERIOR EXIT BY MEANS OF A STAIRWAY OR RAMP SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE FOLLOWING WORDS AS APPROPRIATE: A. "EXIT STAIR DOWN" B. "EXIT RAMP DOWN" C. "EXIT STAIR UP " D. "EXIT RAMP UP" EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVEL EXTERIOR EXIT BY MEANS OF AN EXIT ENCLOSURE THAT DOES NOT UTILIZE A STAIR OR RAMP, OR BY MEANS OF AN EXIT PASSAGEWAY, SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE WORDS "EXIT ROUTE." EACH EXIT ACCESS DOOR FROM AN INTERIOR ROOM OR AREA THAT IS REQUIRED TO HAVE A VISUAL EXIT SIGN, SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE WORDS, "'EXIT ROUTE." EACH EXIT DOOR THROUGH A HORIZONTAL EXIT SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE WORDS "TO EXIT."

11 - 12 - 09 health re-ck.

OCCUPANT LOAD CALULATIONS:


PER TABLE 1004.1.1 2007 C.B.C. TOTAL AREA INSIDE BUILDING = 1509 SQ/FT. AREA OF KITCHEN = 212.75 SQ/FT. = 1:200 = 1 AREA OF SCULLERY = 147 SQ/FT. = 1:200 = 1 AREA OF PREP. = 150 SQ/FT. = 1:200 = 1 AREA OF STORAGE = 378 SQ/FT. = 1:200 = 1 AREA OF OFFICE = 111 SQ/FT. @ 1:100 =1 TOTAL OCCUPANT LOAD: 5 "NOT INCLUDED IN TOTAL OCCUPANT LOAD OF BUILDING" ARE AREA USED BY PEOPLE NORMALLY OCCUPYING OTHER PARTS OF BUILDIN I.E. WALK-IN, RESTROOM, HALLWAYS ETC.

ACCESSIBILITY NOTE
"I AM THE DESIGNER/OWNER IN RESPONSIBLE CHARGE OF THIS TENANT IMPROVEMENT PROJECT; I HAVE INSPECTED THE PREMISES AND DETERMINED THAT EXISTING RESTROOM(S) SERVING AREA(S) OF ALTERATION ARE ACCESSIBLE ACCORDING TO CURRENT REQUIREMENTS SIGNATURE: ___________________ PRINT NAME: __________________ DATE: _______________________ "IF THE BUILDING INSPECTOR DETERMINES NONCOMPLIANCE WITH ANY ACCESSIBILITY PROVISIONS, HE/SHE SHALL REQUIRE COMPLETE, DETAILED PLANS CLEARLY SHOWING ALL EXISTING NON COMPLYING CONDITIONS AND THE PROPOSED MODIFICATIONS TO MEET CURRENT ACCESSIBILITY PROVISIONS AFFECTED BY THE REMODEL (INCLUDING SITE PLAN, FLOOR PLANS, DETAILS, ETC.). THE PLANS MUST BE STAMPED BY THE FIELD INSPECTOR AND RESUBMITTED TO THE BUILDING DEVELOPMENT REVIEW DIVISION."

1. 2.

3.

4. 5.

EXIT REQUIREMENTS
3435 Camino Del Rio South, Suite 215,San Diego, Ca 92108 Tel: 619.284.9227 Fax: 619.284.1463 1. EXIT SIGNS SHALL BE READILY VISIBLE FROM ANY DIRECTION OF APPROACH AND EXIT SIGNS SHALL BE LOCATED TO CLEARLY INDICATE THE DIRECTION OF EGRESS TRAVEL AND SUCH THAT NO POINT SHALL BE MORE THAN 100 FEET FROM THE NEAREST VISIBLE SIGN. CBC 1011.1 2. EXIST SIGNS SHALL BE CONNECTED TO AN EMERGENCY ELECTRICAL POWER SYSTEM. PER (SEC. 1003.2.8.5) BATTERY BACK-UP PROVIDED SEE SHT. E-1 3. PROVIDE EXIT ILLUMINATION THAT HAS A MINIMUM INTENSITY OF NOT LESS THAN 1 FOOT CANDLE AT THE FLOOR LEVEL (SEC. 1003.2.9) 4. POWER FOR THE MEANS OF EGRESS ILLUMINATION SHALL BE PROVIDED BY THE PREMISES ELECTRICAL SUPPLY AND PROVIDE EMERGENCY POWER.

SEE FLOOR PLAN FOR LOCATIONS T.E.S. = TACTILE EXIT SIGN

GENERAL NOTES
1. ALL SIGN DESIGN AND PERMITS BY OTHERS. 2. ALL EQUIPMENT SHALL MEET NATIONAL SANITATION FOUNDATION DESIGN AND INSTALLATION REQUIREMENTS OR IT'S EQUIVALENT. 3. CONTRACTOR TO VERIFY W/EQUIP. SUPPLIER THE MAKE, MODEL AND SIZE OF EQUIP. TO BE NSTALLED. ALSO THEIR ELECT. & MECH. REQUIREMENTS PRIOR TO INSTALLATION. 4. G.C. TO PROVIDE PLYWOOD BACKING BEHIND ALL WALLS WHERE WALL MOUNTED ITEMS OCCUR PRIOR TO INSTALLATION VERIFY AT JOBSITE.

E NS

CON T

RA

C
TO

L IC

DAN LEVY CONSTRUCTION INC.


Lic. # 276003 10/05/09 Date Expires 8/31/10

5 TIER 18x48 18x36

5 TIER 18x36

EXISTING ELECT. PANEL

3 TIER 18x36
POT & PAN STORAGE

OF

CA LI

FO

STORAGE

23 6

F.S.

EXISTING UNISEX RESTRM.

21

18 19 20
F.D.

15 16 17

5 TIER

SCULLERY
18x36

Just Call Us Catering


DRAWN DATE SCALE SHEET

2 4
18x48 5 TIER 3 TIER

7
18x36

9 12 13 14
6'x2'-6" WORK TABLE
5 TIER

30
G

3 TIER

1
OFFICE

DOOR TO BE REMOVED
3040 ONE WAY WINDOW
5 TIER 18x48 5 TIER 5 TIER 18x48

WALK-IN MANUFACTURER: TYLER MODEL 7400295SPL SERIAL 5539692D1


18x48

11
D

F.S.

18x48

10'x12' WALK-IN COOLER 3

KITCHEN
18x48 F.S.

31
G FILLER TAP FISHER 9104 WALL MT.

3 TIER

PREP.

15 16 17 34

32

18x42

6 10
5 TIER

30

3068

5 TIER 18x72 18x72 5 TIER

3 TIER

33
3'
8'x3' WORK TABLE 6'x2'-6" WORK TABLE

1' 6"

5 TIER

18x72

18x72

DELIVERY DOORS

AIR IN

AIR IN

1. FLAME SPREAD CLASSIFICATIONS FOR INTERIOR WALL AND CEILING FINISHES SHALL COMPLY WITH 2007 CBC TABLE 803.5. 2. PROPOSED FLOOR FINISHES SHALL COMPLY WITH ASTM E648 AND SHALL HAVE ASTM E84 SMOKE DENSITY RATING OF LESS THAN 450. CBC 804.4.1, 3. IF EXTERIOR FINISHES ARE ALTERED, EXTERIOR WATER-RESISTIVE BARRIERS WHEN APPLIED OVER WOOD-BASED SHEATHING SHALL INCLUDE A WATER-RESISTIVE VAPOR-PENEABLE BARRIER WITH A PERFORMANCE AT LEAST EQUIVALENT TO TWO LAYERS OF GRADE D PAPER; OR AT LEAST ONE LAYER OF WATER-RESISTIVE BARRIER EQUAL OR GREATER THAN 60-MINUTE GRADE D, PAPER AND WITH A SEPARATION FROM THE EXTERIOR FINISH BY AN INTERVENING SUBSTANTIALLY NON WATER-ABSORBING LAYER OR DRAINAGE SPACE CBC 2510.6. 4. ALL DOORS IN THE MEANS OF EGRESS SHALL BE OPENABLE FROM EGRESS SIDE WITHOUT USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT, AND THAT THE UNLATCHING OF ANY DOOR OR LEAF SHALL NOT REQUIRE MORE THAN ONE OPERATION. CBC 1008.1.8, 1008.1.8.5. 5. FOR GROUP A-2 OCCUPANCIES, KEY-OPERATED LOCKING DEVICES FROM THE EGRESS SIDE MAY BE USED ON THE MAIN EXTERIOR DOORS PROVIDED; A) THE LOCKING DEVICE IS READILY DISTINGUISHABLE AS LOCKED; AND, B) THERE IS A READILY VISIBLE DURABLE SIGN ON OR ADJACENT TO THE DOOR STATING "THIS DOOR MUST REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED"; AND, C) THIS SIGN SHALL BE IN LETTERS NOT LESS THAN 1 INCH HIGH ON A CONTRASTING BACKGROUND; AND, D) THE USE OF THIS EXCEPTION MAY BE REVOKED BY THE BUILDING OFFICIAL AT ANY TIME FOR DUE CAUSE. CBC 1008.1.8.3. 6. MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT PERMITTED ON DOORS. CBC 1008.1.8.4. 7. EFFORT TO OPERATE EACH ACCESSIBLE DOOR TO NOT EXCEED 5 POUNDS FOR EXTERIOR AND INTERIOR DOORS. EFFORT TO OPERATE FIRE DOORS MAY BE INCREASED TO MINIMUM ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 POUNDS. CBC 1133B.2.5. 8. DOORS WITH SELF-CLOSERS TO BE ADJUSTED SO THAT FROM OPEN POSITION THE DOOR LEAF WILL TAKE AT LEAST 3 SCCONDS TO MOVE TO A POSITION 3 INCHES FROM LATCH TO LANDING EDGE OF DOOR. CBC 1133B.2.5.1.

1. AT LEAST ONE FIRE EXTINGUISHER WITH A MINIMUM RATING OF 2-A-10 BC SHALL BE PROVIDED WITHIN 75 FEET MAXIMUM TRAVEL DISTANCE FOR EACH 8,000 SQUARE FEET OR PORTION THEREOF ON EACH FLOOR. CFC SECTION 006 2. COMPLETE PLANS AND SPECIFICATIONS FOR FIRE-EXTINGUISHING SYSTEMS, INCLUDING AUTOMATIC SPRINKLERS AND WET END DRY STANDPIPES: HALON SYSTEMS AND OTHER SPECIAL TYPES OF AUTOMATIC FIRE-EXTINGUISHING SYSTEMS; BASEMENT PIPE INLETS, AND OTHER FIRE-PROTECTION SYSTEMS AND APPURTENANCES THERETO SHALL BE SUBMITTED TO FLRE AND LIFE SAFETY FOR REVIEW AND APPROVAL PILOT INSTALLALATION, [CFC 901.2] 3. BUILDINGS UNDERGOING CONSTRUCTION, ALTERATION OR DEMOLITION SHALL BE IN ACCORDANCE WITH CFC CHAPTER 14 [CFC 1401.1] 4. DECORATIVE MATERIALS SHALL BE MAINTAINED IN A FLAMERETARDANT CONDITION. [TITLE 19, SECT. 3.08, 3.21; CFC 804] 5. FIRE-EXTINGUISHING SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH CFC SECTION 903. 6. ALL VALVES CONTROLLING THE WATER SUPPLY FOR AUTOMATIC SPRINKLER SYSTEMS AND WATER-FLOW SWIICHES ON ALL SPRINKLER SYSTEMS SHALL BE ELECTRICALLY MONITORED WHERE THE NUMBER OF SPRINKLERS IS 20 OR MORE. CFC 803.4 7. INSTALLATION OF FIRE ALARM SYSTEMS SHALL BE IN ACCORDANCE WITH CFC, SECTION 907. 8. EXIT AND EXIT ACCESS DOORS SERVING GROUP A OCCUPANCIES SHALL NOT BE PROVIDED WITH LATCH OR LOCK UNLESS IT IS PANIC HARDWARE EXCEPTION 1. GROUP A DIV 3 0CC. PANIC HARDWARE MAY BE OMITTED FROM THE "MAIN" EXIT PROVIDED A READILY VLSABLE SIGN ADJACENT TO THE DOORWAY STATING 'THIS DOOR MUST REMAIN UNLOCKED DURING BUISNESS HOURS." SHOW PANIC HARDWARE ON DOORS OTHER THAN MAIN EXIT. 9. ADDRESS SHALL BE PROVIDED FOR ALL NEW AND EXISTING BUILDINGS IN A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. (CFC 901.4.4 FHPS POLICY P-00-6) PREMISES IDENTIFICATION NUMBERS TO BE 12" IN HEIGHT WITH A STROKE WIDTH OF 1 1/2". 10. OWNER OR G.C. TO PROVIDE FIRE EXTINGUISHERS RATED AT 2A-10 BC EVERY 75 FEET OF TRAVEL EXTINGUISHERS SHALL BE MOUNTED ON WALLS 3 TO 5 FEET ABOVE FINISHED FLOOR IN ACCESSIBLE AND VISIBLE LOCATIONS DETERMINED BY FRE DEPARTMENT. FIRE EXTINGUISHERS MAY BE INSTALLED IN LOCKED CABINETS WITH FIRE DEPARTMENT APPROVAL. PROVIDE A CLASS 'K' FIRE EXTINGUISHER WITHIN 30 FEET OF THE COOKING APPLIANCES.

18x60

TENANT IMPROVEMENT NOTES

FIRE DEPARTMENT NOTES

3040 ONE WAY WINDOW

18x72

3
3 TIER 3 TIER

10'x6' WALK-IN FREEZER


W/INSUL. FLOOR

18x72

35 6
5 TIER 5 TIER

3'

SPARES

8 22 29

WALL LEGEND
EXISTING STUD WALL EXISTING STUD WALL TO BE REMOVED (NON-BEARING) NEW INTERIOR PARTITION (NON-BEARING) NEW WALK-IN WALL (MANUFACTURED)

N
10 - 20 - 09

1/4" = ONE FOOT

FLOOR PLAN

A-1
3 OF 12 SHEETS

4445 Clairemont Mesa Blvd.

18x72

DRY STORAGE

San Diego, Ca 92117

25 26 27 28

5 TIER

IA

EXISTING 3028 WIN. SILL @ 6'-6" A.F.F.

Signed

ST

3068

3 TIER

5 TIER

5 TIER 18x48 5 TIER 18x48 5 TIER 18x48

18x48 18x48 3 TIER 18x42 18x48 5 TIER 3 TIER 18x60 18x48