Académique Documents
Professionnel Documents
Culture Documents
Pumps
Pump Systems
Components
Subject to technical modifications. In appliance of our General Terms of Delivery and Service (see www.wilo.com)
W2690/2500/0609/GB/MP
Catalogue B3 - 60 Hz - 2007
B3
8
9
4
5
6
10 11
2
9
Wilo-EMU
sewage pump
Series
Catalogue
C2.2
Wilo-EMU
booster pump
Wilo-EMU
borehole pump
B2.2
B2.2
Wilo-EMU
mixer
Wilo-EMU
mixer
Wilo-EMU
mixer
Wilo-EMU Cat.
No. 4
Wilo-EMU Cat.
No. 4
Wilo-EMU Cat.
No. 4
Wilo-EMU Cat.
No. 4
Wilo-EMU
drainage pump
Wilo-EMU solids
separation system
C1
Wilo-EMU
sewage pump
10
11
Wilo-VeroNormNP/NPG
Wilo-ASP
C2.2
Wilo-EMU Cat.
No. 4
A3
A3
14
11
12
13
2
4
6
8
9
7
6
WiloCronoLine-IL-E
A2
WiloSub TWU 8
B2.1
WiloDrainLift L
C3
10
Series
Catalogue
Wilo-Comfort-Vario
COR 3/MHIE VR
Wilo-Stratos-D
WiloCronoLine-IL-E
B4
B4
A1
A2
WiloCronoBloc-BL
A3
Wilo-Stratos-Z
A1
WiloCronoLine-IL
A2
10
11
12
13
14
WiloDrain TP 80
Wilo-VeroNormNP/NPG
Wilo-Vario
COR 4/MVIE VR
WiloEconomy MHI
A3
B4
C2.1
B3
B4
Contents
High Pressure Multistage Centrifugal Pumps
8
Nasslufer-Pumpen
Single-head pumps
Series overview
10
Equipment/Function
11
Technical data
12
Wilo-Multicargo MC
Pump curves, motor data
13
Dimensions, weights
14
Wilo-Multipress MP
15
Dimensions, weights
16
Systeme
Equipment/Function
21
Planning guide
23
Wilo-Economy MHI
Variants overview
28
Technical data
30
Pump curves
32
33
Dimensions, weights
34
Trockenlufer-Pumpen
Single-head pumps
Series overview
Wilo-Economy MHIL
35
Technical data
37
Pump curves
39
40
Dimensions, weights
41
Variants overview
Wilo-Economy MVI
Variants overview
42
Technical data
44
Pump curves
48
53
Dimensions, weights
55
Variants overview
77
Technical data
79
Pump curves
81
82
Dimensions, weights
83
Pumpenmanagement
Wilo-Economy MVIL
Contents
High Pressure Multistage Centrifugal Pumps
Wilo-Economy MHIE
Variants overview
85
Technical data
87
Pump curves
89
96
Dimensions, weights
97
Wilo-Economy MVIE
Variants overview
98
Technical data
100
Pump curves
102
134
Dimensions, weights
136
Abbreviation
Meaning
1~
LON
3~
Autopilot
Automatic adjustment of pump output during setback phases, e.g. boiler setback operation overnight
MOT
rbc
PLR
DM
Three-phase AC motor
Pt 100
p-c
p-T
Q (= V )
Flow volume
SBM
p-v
SSM
Control input
0...10 V
EM
EnEV
TOPControl
ECMtechnology
TrinkwV
2001
VDI 2035
Ext. Off
Ext. Min
Control input "Overriding Min, e.g. for setback operation without autopilot
WRAS
WSK
RCD
Residual-current device
BA
Building automation
GRD
Mechanical seal
GTW
Delivery head
IF
Interface
Inox
Stainless steel
Int. MS
IR
Infrared interface
Cap
Capacitor
TRS
KTL- coating
Cataphoretic painting:
Paintwork with high adhesive strength for longlasting corrosion protection
KTW
Systeme
Meaning
Trockenlufer-Pumpen
Abbreviation
Nasslufer-Pumpen
Pumpenmanagement
Wear
Pumps or parts of pumps are subject to wear in accordance with state-ofthe-art technology (DIN 31051/DIN-EN 13306). This wear may vary depending on operating parameters (temperature, pressure, water condition) and the installation/usage situation and may result in the malfunction or failure at different times of the above-mentioned products/components including their electrical/electronic circuitry.
Wear parts are all components subject to rotatory or dynamic strain including electronic components under tension, in particular:
- seals (incl. mechanical seal), seal ring
- bearings and shaft
- stuffing boxes
- capacitor
- relays / contactors / switches
- electronic circuits, semiconductor components, etc.
- impellers
- wearing rings / wearing plates
We do not accept liability for faults or defects arising from natural wear
and tear.
Note
According to the German energy saving act EnEV boiler outputs of more
than 25 kW require the use of heating pumps with switchgears for automatic output control or the use of electronically controlled pumps from
1.2.2002 onwards.
In accordance with TrinkwV 2001 and DIN 50930-6 only circulating
pumps with corrosion-resistant pump housings in stainless steel or red
bronze (CC 491K) are to be used in drinking water circulation systems.
Pump replacement
Please refer to the current Wilo heating pumps replacement guide for
more detailed information.
Pumpenmanagement
Trockenlufer-Pumpen
Systeme
Nasslufer-Pumpen
Wilo-Multipress MP
Wilo-Economy MHI
S/M/C
Wilo-Economy MHIL
S/M/C
S/M/C
Wilo-Multivert MVI
S/M/C
Wilo-Multivert MVIL
S/M/C
Wilo-Multivert-MHIE
S/M/C
Wilo-Multivert-MVIE
S/M/C
Speedcontrolled
Fixed speed
Wilo-Multicargo MC
Self-priming
Submerged
motor pumps
Design
Normalpriming
Pump type
S/M/C S/M/C
Page
Legend:
S
Single- and two-family
house
M
Multi-family house
C
Commercial
applicable
Nasslufer-Pumpen
Self-supply of water
13
15
Rainwater utilisation
(as compact plant with
expandable accumulator
tanks)
Rainwater utilization
(in conjunction with buried
tank or cistern)
Sprinkler services
M/C
M/C
M/C
M/C
M/C
M/C
M/C
M/C
28
M/C
M/C
M/C
M/C
M/C
M/C
M/C
35
M/C
M/C
M/C
S/M/C S/M/C
M/C
M/C
M/C
M/C
M/C
42
M/C
M/C
M/C
S/M/C S/M/C
M/C
M/C
M/C
M/C
M/C
77
M/C
M/C
M/C
S/M/C S/M/C
M/C
M/C
M/C
M/C
M/C
85
M/C
M/C
M/C
S/M/C S/M/C
M/C
M/C
M/C
M/C
M/C
98
Systeme
Irrigation
Sprinkling/irrigation
Well and cistern water
supply
Cooling-water circuits
Trockenlufer-Pumpen
Cold-water circuits
Pure-water circuits
Drinking-water supply
Pressure boosting systems
Water supply for firefighting
Car washes
Industrial applications
Boiler feed
Pumpenmanagement
Process engineering
H [m]
Series: Wilo-MultiCargo MC
Wilo-MultiCargo MC
60 Hz
60
50
40
30
MC 300
20
MC 600
10
0
Q [m/h]
H [m]
Series: Wilo-MultiPress MP
Wilo-MultiPress MP
60 Hz
60
50
40
30
MP 300
MP 600
20
10
0
10
Q [m/h]
WiloMultiPress MP
Self-priming
Non self-priming
Filter pump
Glandless technology
Prefilter
Support frame
Installation manual
Nasslufer-Pumpen
Hydraulic data
Trockenlufer-Pumpen
Systeme
Motor
Pumpenmanagement
11
WiloMultiPress MP
Rainwater
10
10
68
68
Approved fluids
Performance
+5 up to +35
+5 up to +35
40
40
10
220
220
380
380
220
220
60
60
3500
3500
Protection class
IP 54
IP 54
Insulation class
1.4301
1.4301
Noryl
Noryl
Shaft
1.4028
1.4404 (1.1 kW)
1.4028
1.4404 (1.1 kW)
Mechanical seal
Carbon/ceramic
Carbon/ceramic
Stage chambers
Noryl
Noryl
Diffusor/Injector
NBR
NBR
Motor
Pipe connection
Materials
Pump housing
Impeller
Seals
= available, = not available
12
n = 3500 rpm
n = 3500 rpm
70
60
MC 604
60 Hz
Nasslufer-Pumpen
60 Hz
60
50
50
MC 304
MC 603
H [m]
MC 303
30
20
10
3
0.8
p
NPSH
0
Q [m/h]
1.2 Q [l/s]
1.0
Q [m/h]
8
6
4
2
0
50
40
30
20
10
0
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
1.0
MC 304
P2 [kW]
0.8
0.6
MC 303
0.4
0.2
0
Q [m/h]
1
0.2
2
0.4
0.6
0.8
4
1.0
5
1.2
1.4
Q [m/h]
6
1.6
1.8
Q [l/s]
p
NPSH
0
Q [m/h]
Q [m/h]
6
4
2
0
MC 604
MC 603
Trockenlufer-Pumpen
0
0
Systeme
0.6
p [%]
2
0.4
P2 [kW]
p [%]
1
0.2
NPSH [m]
0
0
40
30
20
10
0
30
20
10
0
40
NPSH [m]
H [m]
40
Nominal current IN at
1~220 V
[kW]
3~220 V
3~380 V
[A]
0.75
5.2
3.3
1.9
MC 304
1.1
8.4
5.3
3.1
MC 603
1.1
8.4
5.3
3.1
MC 604
1.5
10.8
9.9
4.0
Pumpenmanagement
MC 303
Wilo-MultiCargo ...
13
D3
3~
L3
104
16
H1
D1
D2
1~
1/4"
43,5
1/4"
8.5
L1
108
150
L
170
190
Dimensions, weights
Wilo-MultiCargo ...
Dimensions
H
1~220 V
H1
3~380 V
L
1~220 V
L1
Weight
L3
D1
D2
3~380 V
D3
1~220 V
[mm]
14
MC 303
216
192
MC 304
224
192
90
448
423
253
MC 603
224
192
90
448
423
253
MC 604
224
206
90
448
448
253
157.5
90
423
3~380 V
1~220 V
Pg
423
253
157.5
3~380 V
[kg]
Rp 1 Rp 1
13.5
11
10.7
9.8
157.5
Rp 1 Rp 1
13.5
11
10.9
11.8
157.5
Rp 1 Rp 1
13.5
11
13.2
11.3
Rp 1 Rp 1
13.5
11
14.5
13.1
n = 3500 rpm
n = 3500 rpm
70
70
Wilo-MultiPress MP 302-304
MP 304
60
60 Hz
50
MP 603
10
10
2
0.4
0.6
3
0.8
4
1.0
1.4
Q [l/s]
1.6
p
NPSH
0
6Q [m/h]
5
1.2
6Q [m/h]
10
8
6
4
2
0
MP 302
Q [m/h]
NPSH
20
0
Q [m/h]
Q [m/h]
10
8
6
4
2
0
1.4
P2 [kW]
MP 303
0.6
3
p
40
MP 604
1.2
0.8
0.4
MP 603
1.0
0.8
MP 602
0.6
0.4
0.2
0.2
0
6Q [m/h]
Trockenlufer-Pumpen
0.0
0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 Q [l/s]
60
MP 304
1.0
0
0
p [%]
40
30
20
10
0
1
0.2
Systeme
20
MP 602
30
20
1.2
P2 [kW]
40
NPSH [m]
MP 302
30
0
p [%]
H [m]
40
NPSH [m]
H [m]
MP 303
60 Hz
60
50
Nasslufer-Pumpen
Nominal current IN at
1~220 V
[kW]
3~220 V
3~380 V
[A]
0.55
3.7
MP 303
0.75
5.2
3.3
1.9
MP 304
1.1
8.4
5.3
3.1
MP 602
0.75
5.2
3.3
1.9
MP 603
1.1
8.4
5.3
3.1
MP 604
1.5
10.8
9.9
4.0
Pumpenmanagement
MP 302
Wilo-MultiPress ...
15
D3
3~
L3
104
16
H1
D1
D2
1~
1/4"
43,5
1/4"
8.5
L1
108
150
L
170
190
Dimensions, weights
Wilo-MultiPress ...
Dimensions
H
H1
1~220 V 3~380 V
Pgcable glands
l1
l3
D1
D2
1~220 V 3~380 V
D3
1~220 V 3~380 V 1~220 V 3~380 V
[mm]
16
Weight
Pg
[kg]
MP 302
216
90
375
205
109.5
Rp 1
Rp 1
13.5
8.8
MP 303
216
192
90
375
375
205
109.5
Rp 1
Rp 1
13.5
11
9.8
8.9
MP 304
224
192
90
448
423
253
157.5
Rp 1
Rp 1
13.5
11
11.6
10.7
MP 602
216
192
90
375
375
205
109.5
Rp 1
Rp 1
13.5
11
9.6
8.7
MP 603
224
192
90
400
375
205
109.5
Rp 1
Rp 1
13.5
11
11.9
11.2
MP 604
224
206
90
448
448
253
157.5
Rp 1
Rp 1
13.5
11
13.4
12.5
MHI 800
MHI 400
60 Hz
MHI 200
80
70
60
50
40
30
20
10
0
Wilo-Economy-MHI
MHI 1600
10
15
20
25Q[m/h]
Nasslufer-Pumpen
H[m]
60 Hz
80
60
40
MHIL
100
MHIL
300
MHIL
500
MHIL 900
20
10
12 Q [m/h]
Pumpenmanagement
Systeme
Wilo-Economy-MHIL
Trockenlufer-Pumpen
H [m]
17
H[m]
200
160
40
0
MVI 800
MVI 1600-6
10
15
H[m]
MVI 400
80
MVI 200
MVI 100
120
20
25Q[m/h]
Wilo-Multivert MVI
60 Hz
200
40
60
MVI 7000
80
MVI 5200
MVI 1600
120
MVI 3200
160
MVI 9500
40
0
20
80
100
120 Q[m/h]
H[m]
120
100
80
60
40
MVIL
100
MVIL
300
MVIL
500
MVIL
900
20
0
0
18
10
12
14
Q[m/h]
Wilo-Economy MHIE
80
MHIE 400
60
40
20
MHIE 800
MHIE 200
MHIE 1600
0
4
12
16
20
24
Q[m/h]
Pumpenmanagement
Trockenlufer-Pumpen
Systeme
Nasslufer-Pumpen
H[m]
19
H[m]
160
120
40
0
20
10
MVIE 800
60
MVIE 400
MVIE 200
80
MVIE 1600-6
100
MVIE 5200
MVIE 3200
20
30
40
50
60
70
80
Q[m/h]
Equipment /Function
WiloEconomy
MHI
WiloEconomy
MHIL
WiloMultivert
MVI
WiloMultivert
MVIL
Glandless pump
Self-venting
Hydraulic in 1.4301
1.. up to 16..-6
Hydraulic in 1.4301
Pump base in EN-GJL-250
16.. to 95..
Threaded connection
Victaulic connections
Three-phase-DIN motor
DM (three-phase motor)
EM (AC motor)
(only 1~)
(only 1~)
(only 1~)
optional
(only on version
PN 16)
2.. to 8..
2.. up to 16..-6
Hydraulic in 1.4404
Pump base in EN-GJL-250
16.. to 95..
on request
on request
on request
on request
Systeme
Nasslufer-Pumpen
Hydraulic data
Trockenlufer-Pumpen
Motor
Equipment/scope of delivery
Hydraulic in 1.4404
Pumpenmanagement
Options
21
Equipment /Function
WiloEconomy MHIE
WiloMultivert MVIE
Glandless pump
Self-venting
Hydraulic in 1.4301
2.. up to 16..-6
Hydraulic in 1.4301
Pump base in EN-GJL-250
16.. to 52..
Threaded connection
Victaulic connections
Three-phase-DIN motor
DM (three-phase motor)
EM (AC motor)
Hydraulic data
Motor
(only 1~ version)
(only 1~ version)
Equipment/scope of delivery
Oval mating flange Rp 1 up to Rp 11/2
2.. to 4..
2.. up to 16..-6
Hydraulic in 1.4404
Pump base in EN-GJL-250
16.. to 52..
Options
Hydraulic in 1.4404
22
Planning guide
This list is not necessarily complete. Data on the application limits of different pump materials when handling any of the listed fluids have been
conscientiously prepared to the best available knowledge. However, the
information must be regarded only as a non-binding guide to these characteristics. Guarantee claims of any kind must not be derived on the
basis of this information.
In practice it is unlikely that only the pure substances listed here will be
contained in the pumped media. Even small additions of other matter can
decisively influence or change the chemical aggression of a basic substance. Detrimental effects can also be attributed to incrustations, condensate or temperature changes. In many cases only practical experience
can provide adequate evidence of the suitability of a particular material.
Note
Viton in combination with water is only resistant up to 90 C max.
We therefore request that sufficient attention be given to the relevant
footnotes and other remarks that are appended to the information.
Questions related to the chemical and other resistance of the Wilo-Multivert MVI/MVIE-Series 16.., 32.., 52.. should be directed to your respective
Wilo sales office or representative.
Nasslufer-Pumpen
Remarks
In addition to this list of resistance characteristics, the properties of the
flow medium, such as density, solidification point, viscosity, etc., as well
as Ex-protection requirements, should be given separate and additional
consideration.
The limits of applicability of the pumps, based on pressure and temperature, must also be observed.
EPDM
Viton
EPDM
Viton
Alkaline cleaner
Aluminium sulphate
10%
25
100%
80
15%
60
10%
40
Ammonium sulphate
20%
50
Antifrogen (KW-Basis)
40%
70
Cider
60
25
Benzoic acid
10%
100
Unsaturated
solution
60
Brandy
60
Butanol
60
Buttermilk
Boric acid
Calcium acetate
Unsaturated
solution
100
Calcium hydroxide
10%
80
Calcium nitrate
10%
30
50
80
Iron phosphate
Trockenlufer-Pumpen
Pumped fluid
Temp. C
max.
Pumpenmanagement
Vol.-%
max.
Systeme
23
Planning guide
Fluid adaptability chart
Vol.-%
max.
Temp. C
max.
Pumped fluid
EPDM
Viton
EPDM
Viton
Iron-II-sulphate
Iron-III-sulphate
Oil
80
Peanut oil
10%
60
25
60
40 %
70
Fixer
25
Fruit juice
60
Unsaturated
solution
Boiling point
Glycerine
glycol
40 %
70
Uric acid
Hexane
40
Hydraulic oil
Unsaturated
solution
100
10 %
60
Potassium hydrate
10 %
60
Potassium nitrate
Potassium permanganate
Unsaturated
solution
80
Potassium sulphate
Unsaturated
solution
60
10 %
80
25
Copper sulphate
Unsaturated
solution
60
Lubricant coolant
80
Linseed oil
60
60
Tannic acid
glycol-water
Potassium carbonate
24
Planning guide
Fluid adaptability chart
1.4301 (AISI 304)
EPDM
Viton
EPDM
Viton
60
100
50 %
60
60
60
Unsaturated
solution
25
60
Sodium carbonate
10 %
60
Sodium hydroxide
25 %
20
Sodium hydroxide
10 %
80
Unsaturated
solution
80
5%
110
Boiling temperature
120
Maize oil
100
Mineral oil
80
Rapeseed oil
100
Castor oil
100
Lubricating oil
Cutting oil
Soybean oil
100
Oil of turpentine
60
100
10%
250
Oxalic acid
Paraffin(s)
Pumped fluid
Liqueur
Magnesium sulphate
Maize oil
Maleic acid
Lactic acid
Unsaturated
solution
Nasslufer-Pumpen
Temp. C
max.
Systeme
Vol.-%
max.
Miscella
Sodium nitrate
Sodium phosphate
Sodium sulphate
Trockenlufer-Pumpen
Carbonate lye
Fruit pulp (containingSO 2)
Pumpenmanagement
Oil-water-mixture
Oil:
25
Planning guide
Fluid adaptability chart
Vol.-%
max.
Temp. C
max.
Pumped fluid
Phosphoric acid
Polyglycols
Polyethylene glycols
EPDM
Viton
EPDM
Viton
10 %
85
90
40 %
70
60
2-Propanol
Pulps, see fruit pulps
Rapeseed oil
100
Ricine
100
Unsaturated
solution
25
100 %
80
Sulphuric acid
5%
25
Sulphuric acid
2.50 %
60
20
Safety refrigerants
(e.g. Freon, Frigen. etc., free of water)
Silicone oil
100
Cooking oil
100
Terpentine (Oil)
60
10 %
Boiling temperature
10 %
80
10 %
80
35
Deionic
50
Distilled water
50
Decarbonated water
Soft water
Heating water
Tap water
Salicylic acid
Ammonia solution (Ammonium hydroxide)
Trisodium phosphate
Toluene
26
Planning guide
Fluid adaptability chart
Temp. C
max.
Pumped fluid
EPDM
Viton
EPDM
Viton
Pure water
Drinking water
Wine acid
Unsaturated
solution
60
Citric acid
5%
25
Nasslufer-Pumpen
Vol.-%
max.
Trockenlufer-Pumpen
Systeme
Other water:
Pumpenmanagement
27
Seals
EPDM
Viton
Hydraulic connection
Threaded connection
Oval flange
Round flange
Motor versions
Individual motors
optional
1~230 V, 50 Hz
3~230 V, 50 Hz
3~400 V, 50 Hz
3~500 V, 50 Hz
1~110 V, 60 Hz
1~220 V, 60 Hz
3~380 V, 60 Hz
3~400 V, 60 Hz
optional
3~440 V, 60 Hz
optional
3~460 V, 60 Hz
3~480 V, 60 Hz
IP 54
IP 55
Ex-protected motors
(at 1~ motors)
28
Nasslufer-Pumpen
Paint finish
Individual paint finishes
optional
Mechanical seals
Tungsten carbide/carbon
optional
SiC/SiC
optional
KTW
WRAS
Systeme
Pumpenmanagement
Trockenlufer-Pumpen
29
4..
8..
16..
Condensate
Water-glycol mixture
(Up to 40% Vol. glycol / from 10% Vol.glycol performance verification required)
10
18
26
101
97
68
34
-15 to +110
-15 to +110
-15 to +110
-15 to +110
40
40
40
40
10
10
10
10
3500
3500
3500
3500
Approved fluids
220/60 or 230/50
220/60 or 230/50
380/60 Y or 400/50 Y
Insulation class
EN 61800-3
EN 61800-3
EN 61800-3
EN 61800-3
IP 54
IP 54
IP 54
IP 54
11/4
11/2
Victaulic-connections
Impellers
1.4301/1.4404
1.4301/1.4404
1.4301/1.4404
1.4301/1.4404
Stage chambers
1.4301/1.4404
1.4301/1.4404
1.4301/1.4404
1.4301/1.4404
Pump housing
1.4301/1.4404
1.4301/1.4404
1.4301/1.4404
1.4301/1.4404
1.4404
1.4404
1.4404
1.4404
Materials
Shaft
= available, = not available
30
4..
8..
16..
Seal
EPDM
(EP 851)/Viton
EPDM
(EP 851)/Viton
EPDM
(EP 851)/Viton
EPDM
(EP 851)/Viton
Housing cover
1.4301/1.4404
1.4301/1.4404
1.4301/1.4404
1.4301/1.4404
Housing base
Mechanical seal
Pressure jacket
Bearing
Pump base
Pump base (in contact with the flow medium)
Nasslufer-Pumpen
Materials (continued)
B-Carbon/Tungsten carbide
1.4301/1.4404
1.4301/1.4404
1.4301/1.4404
1.4301/1.4404
Tungsten carbide
Tungsten carbide
Tungsten carbide
Tungsten carbide
Aluminium
Aluminium
Aluminium
Aluminium
Systeme
Pumpenmanagement
Trockenlufer-Pumpen
Note on materials:
1.4301 satisfies AISI 304, 1.4404 satisfies AISI 316L.
31
MHI 206
Wilo-Economy-MHI 202-206
80
MHI 406
Wilo-Economy-MHI 402-406
90
60 Hz
MHI 205
80
MHI 204
70
MHI 404
H [m]
60
H [m]
60
60 Hz
MHI 405
MHI 203
40
MHI 403
50
40
MHI 202
MHI 402
30
20
20
10
2.0
3.0
Q [l/s]
3.5
NPSH
1
5 Q [m/h]
1.2
MHI 206
MHI 205
0.8
MHI 204
MHI 203
0
0
20
0
1.6
5 Q [m/h]
4
2.5
60
40
20
Q [l/s]
NPSH
0
2.4
8 Q [m/h]
6
4
2
0
6
4
2
0
MHI 406
2.0
MHI 202
8 Q [m/h]
0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2
NPSH [m]
1.5
40
P2 [kW]
2
1.0
NPSH [m]
1
0.5
P2 [kW]
p [%]
p [%]
NPSH [m]
MHI 405
MHI 404
1.6
1.2
MHI 403
0.8
MHI 402
0.4
0.4
0
5 Q [m/h]
8 Q [m/h]
Wilo-Economy-MHI 802-804
60 Hz
MHI 804
Wilo-Economy-MHI 1602
60 Hz
30
MHI 1602
60
25
MHI 803
40
H [m]
H [m]
50
MHI 802
20
15
30
10
20
10
0.5
4
1.0
6
1.5
8
2.0
3.0
Q [l/s]
p
NPSH
0
10
2.5
MHI 804
2.0
MHI 803
Q [m/h]
0
0
4
3
2
1
0
60
40
20
0
5
1
10
2
15
4
25 Q [m/h]
20
5
Q [l/s]
p
NPSH
0
10
15
20
25 Q [m/h]
2.5
2.0
1.5
MHI 1602
MHI 802
1.0
1.5
1.0
0.5
0.5
0
Q [m/h]
10
2.5
p [%]
NPSH [m]
60
40
20
0
P2 [kW]
P2 [kW]
p [%]
10
Q [m/h]
10
15
20
25 Q [m/h]
32
W2
U2
V2
U1
V1
W1
W2
U1
W1
L
L1
L2
Nasslufer-Pumpen
1~220 V
3~380 V
L3
3~220 V
W2
U2
V2
U1
V1
W1
L1
L2
L3
Nominal output P2
Nominal current IN
1~220 V
3~220 V
3.7
2.6
1.5
[A]
0.55
MHI 203
0.75
5.2
3.3
1.9
MHI 204
1.1
8.4
4.6
2.7
MHI 205
1.1
8.4
4.6
2.7
MHI 206
1.5
10.8
6.9
4.0
MHI 402
0.75
5.2
3.3
1.9
MHI 403
1.1
8.4
4.6
2.7
MHI 404
1.5
10.8
6.9
4.0
MHI 405
1.85
7.8
4.5
MHI 406
2.2
8.9
5.1
MHI 802
1.5
10.8
6.9
4.0
MHI 803
1.85
7.8
4.5
MHI 804
2.5
9.7
5.6
MHI 1602
2.2
8.9
5.1
Pumpenmanagement
MHI 202
Trockenlufer-Pumpen
[kW]
3~380 V
Wilo-Economy
Systeme
Motor data
33
L3
L3
106
"
106
"
D1
H1
H1
D1
105
D2
104
D2
"
L1
L2
L
"
L1
108
L2
108
190
190
Dimensions, weights
Wilo-Economy
Dimensions
D1
D2
H
1~
220 V
Weight
H1
3~
380 V
1~
220 V
L
3~
380 V
1~
220 V
L1
3~
380 V
L2
1~
220 V
L3
3~
380 V
1~
220 V
[mm]
[kg]
MHI 202
Rp 1
Rp 1
216
192
90
90
375
375
205
95
95
110
9.8
8.9
MHI 203
Rp 1
Rp 1
216
192
90
90
375
375
205
95
95
110
10.8
10.9
MHI 204
Rp 1
Rp 1
224
192
90
90
448
423
252
103.5
95
158
12.8
11.9
MHI 205
Rp 1
Rp 1
224
192
90
90
448
423
252
103.5
95
158
14.8
14.0
MHI 206
Rp 1
Rp 1
224
206
90
90
472
472
276
103.5
103.5
182
14.5
14.5
Rp
11/4
Rp 1
216
192
90
90
375
375
204
95
95
110
10.8
9.9
MHI 403
Rp
11/4
Rp 1
224
192
90
90
400
375
204
103.5
95
110
12.9
12.0
MHI 404
Rp 11/4
Rp 1
224
206
90
90
448
448
252
103.5
103.5
158
15.0
14.1
MHI 405
Rp
11/4
Rp 1
206
90
448
252
103.5
158
14.7
MHI 406
Rp 11/4
Rp 1
211
100
511
276
136.5
182
20.3
MHI 802
Rp 11/2
Rp 11/4
224
206
90
90
412
412
216
103.5
103.5
122
18.6
13.4
MHI 803
Rp
11/2
11/4
206
90
412
216
103.5
122
14.0
MHI 804
Rp 11/2
Rp 11/4
221
100
511
276
136.5
182
23.3
MHI 1602
Rp 2
Rp 11/2
221
100
471
236
136.5
138
20.9
MHI 402
34
3~
380 V
Rp
Nasslufer-Pumpen
Material
Seals
EPDM
Viton
Threaded connection
Oval flange
Round flange
Systeme
Hydraulic connection
1~230 V, 50 Hz
3~230 V, 50 Hz
3~400 V, 50 Hz
optional
3~500 V, 50 Hz
1~110 V, 60 Hz
1~220 V, 60 Hz
3~380 V, 60 Hz
3~400 V, 60 Hz
3~440 V, 60 Hz
3~460 V, 60 Hz
3~480 V, 60 Hz
IP 54
IP 55
Ex-protected motors
Pumpenmanagement
Individual motors
Trockenlufer-Pumpen
Motor versions
(only 1~220 V)
35
optional
Mechanical seals
Tungsten carbide/carbon
SiC/carbon
optional
optional
SiC/SiC
optional
WRAS
36
3..
5..
9..
Condensate
Water-glycol mixture
(Up to 40% Vol. glycol / from 10% Vol.glycol performance verification required)
10
18
96
95
80
49
-15 to +90
-15 to +90
-15 to +90
-15 to +90
40
40
40
40
10
10
10
10
3500
3500
3500
3500
Nasslufer-Pumpen
Approved fluids
Trockenlufer-Pumpen
Systeme
Motor
Mains connection 1~ [V/Hz]
(Permissible voltage tolerance 10%)
220/60 or 230/50
220/60 or 230/50
380/60 Y or 400/50 Y
Insulation class
IP 54
IP 54
IP 54
IP 54
Victaulic-connections
1.4301
1.4301
1.4301
1.4301
Protection class
Connections
Materials
Impellers
Pumpenmanagement
37
Stage chambers
1..
3..
5..
9..
1.4301
1.4301
1.4301
1.4301
Materials (continued)
Pump housing
Shaft
1.4028
1.4028
1.4028
1.4028
Seal
EPDM
EPDM
EPDM
EPDM
Housing cover
Housing base
Mechanical seal
SiC/carbon
SiC/carbon
SiC/carbon
SiC/carbon
Pressure jacket
Tungsten carbide
Tungsten carbide
Tungsten carbide
Tungsten carbide
Bearing
Pump base
Pump base (in contact with the flow medium)
38
100
80
70
MHIL
100
Wilo-MHIL 102-107
MHIL
107
MHIL
106
90
60 Hz
80
MHIL 304
60
40
MHIL 103
30
MHIL 102
H [m]
H [m]
MHIL 305
105
50
Wilo-MHIL 302-306
MHIL 306
60 Hz
60
MHIL 1
Nasslufer-Pumpen
04
MHIL 303
40
MHIL 302
20
20
10
0.2
2.0
0.4
0.6
20
NPSH
0
0.5
1.0
1.5
2.0
0.8
0.6
MHIL 105
MHIL 104
0.4
MHIL 103
0.2
MHIL 102
0
0.5
1.0
1.5
2.0
12
8
4
0
50
40
30
20
10
0
1
0.2
2
0.4
1.2
1.4
Q [l/s]
12
8
4
NPSH
0
5 Q [m/h]
MHIL 305
1.2
MHIL 304
0.8
MHIL 303
MHIL 302
0.4
0
Q [m/h]
2.5
5 Q [m/h]
50
Wilo-MHIL 902-903
MHIL 903
MHIL 505
60 Hz
40
70
MHIL 504
MHIL 902
30
50
MHIL 503
40
H [m]
H [m]
1.0
60 Hz
60
5 Q [m/h]
0.8
MHIL 306
Wilo-MHIL 502-505
80
0.6
1.6
90
0
0
MHIL 107
MHIL 106
1.0
P2 [kW]
Q [m/h]
2.5
1.2
Q [l/s]
40
0
0.8
P2 [kW]
p [%]
60
Q [m/h]
2.5
Systeme
1.5
Trockenlufer-Pumpen
1.0
NPSH [m]
0.5
p [%]
NPSH [m]
20
30
MHIL 502
20
10
10
2
P2 [kW]
20
NPSH
0
Q [m/h]
40
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
Q [m/h]
0
0
8
6
4
2
0
60
40
20
0
2
0.4
4
0.8
1.2
1.6
8
2.0
MHIL 505
MHIL 504
MHIL 503
MHIL 502
10
2.4
2.8
12
3.2
Q [m/h]
3.6 Q [l/s]
NPSH
2.0
10
12
Q [m/h]
12
Q [m/h]
MHIL 903
1.6
P2 [kW]
p [%]
60
MHIL 902
1.2
Pumpenmanagement
0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 Q [l/s]
NPSH [m]
p [%]
NPSH [m]
0.8
0.4
Q [m/h]
10
39
3~380 V
W2
U2
V2
U1
V1
W1
W2
U1
W1
L
L1
L2
L3
3~220 V
W2
U2
V2
U1
V1
W1
L1
L2
L3
Motor data
Wilo-Economy
Nominal power P2
Nominal current IN
1~220 V, 60 Hz
3~220 V, 60 Hz
[kW]
40
3~380 V, 60 Hz
[A]
MHIL 102
0.55
3.7
2.6
1.5
MHIL 103
0.55
3.7
2.6
1.5
MHIL 104
0.55
3.7
2.6
1.5
MHIL 105
0.75
5.2
3.3
1.9
MHIL 106
1.1
8.4
4.6
2.7
MHIL 107
1.1
8.4
4.6
2.7
MHIL 302
0.55
3.7
2.6
1.5
MHIL 303
0.75
5.2
3.3
1.9
MHIL 304
1.1
8.4
4.6
2.7
MHIL 305
1.5
10.8
6.9
4.0
MHIL 306
1.5
10.8
6.9
4.0
MHIL 502
0.75
5.2
3.3
1.9
MHIL 503
1.1
8.4
4.6
2.7
MHIL 504
1.5
10.8
6.9
4.0
MHIL 505
1.85
7.8
4.5
MHIL 902
1.5
10.8
6.9
4.0
MHIL 903
1.85
7.8
4.5
D3
D3
10,5
H1
D1
H2
1/4"
Nasslufer-Pumpen
D2
12
58
108
L1
138
Systeme
Dimensions, weights
MHIL 102
Rp 1
MHIL 103
D2
D3
H1
H2
L
1~
220V
l1
l2
3~
380V
Weight
1~
220V
3~
380V
1~
220V
3~
380V
1~
220V
3~
380V
1~
220V
Rp 1
13.5
11
216
192
90
104
145
145
15.1
15.1
Rp 1
Rp 1
13.5
11
216
192
90
104
145
145
15.8
15.8
MHIL 104
Rp 1
Rp 1
13.5
11
216
192
MHIL 105
Rp 1
Rp 1
13.5
11
216
192
90
104
145
145
16.5
16.3
90
104
145
145
15.5
17
MHIL 106
Rp 1
Rp 1
19.5
11
224
192
90
104
440.0 415.2
183.5
162
145
18.8
17.5
MHIL 107
Rp 1
Rp 1
11
11
224
192
90
104
162
145
19.4
17.5
MHIL 302
Rp 1
Rp 1
15.5
11
216
192
90
104
145
145
13.5
15.5
MHIL 303
Rp 1
Rp 1
13.5
11
216
192
90
104
145
145
16.1
16.1
MHIL 304
Rp 1
Rp 1
13.5
11
224
192
90
104
162
145
18.2
16
MHIL 305
Rp 1
Rp 1
13.5
13.5
224
206
90
104
162
162
19
19
MHIL 306
Rp 1
Rp 1
13.5
11
224
206
90
104
458.0 458.0
210.5
162
162
20
20
MHIL 502
Rp 1
Rp 1
13.5
11
216
192
90
104
145
145
14.5
15.4
MHIL 503
Rp 1
Rp 1
13.5
11
224
192
90
104
162
145
17.4
16.2
MHIL 504
Rp 1
Rp 1
13.5
13.5
224
206
90
104
162
162
18.3
18.0
MHIL 505
Rp 1
Rp 1
13.5
206
90
104
162
19.1
MHIL 902
Rp 1 Rp 1
13.5
13.5
224
206
90
104
162
162
18.5
16.7
MHIL 903
Rp 1 Rp 1
13.5
206
90
104
162
19.0
[mm]
3~
380V
[kg]
237
264
Pumpenmanagement
Trockenlufer-Pumpen
D1
WiloEconomy
41
EPDM
Viton
Threaded connection
Oval flange
Round flange
Individual motors
optional
optional
optional
1~230 V, 50 Hz
optional
3~230 V, 50 Hz
optional
optional
optional
3~400 V, 50 Hz
3~500 V, 50 Hz
optional
optional
optional
1~110 V, 60 Hz
optional
optional
1~220 V, 60 Hz
optional
3~220 V, 60 Hz
on request
3~380 V, 60 Hz
optional
optional
3~400 V, 60 Hz
optional
optional
optional
3~440 V, 60 Hz
optional
optional
optional
3~460 V, 60 Hz
optional
optional
optional
3~480 V, 60 Hz
Material
Seals
Hydraulic connection
Motor versions
optional
optional
optional
IP 44
IP 54
IP 55
Ex-protected motors
optional
optional
optional
optional
optional
optional
optional
optional
optional
optional
optional
optional
42
optional
(up to=1.5 kW inclusive)
optional
optional
optional
optional
optional
optional
SiC/SiC
optional
optional
optional
KTW
WRAS
Nasslufer-Pumpen
Paint finish
Individual paint finishes
Mechanical seals
Tungsten carbide/carbon
Systeme
Pumpenmanagement
Trockenlufer-Pumpen
43
2..
4..
8..
16..-6
16..
32..
52..
Condensate
Water-glycol mixture
(Up to 40% Vol. glycol / from 10% Vol.glycol performance verification required)
14
26
26
50
70
230
230
230
190
103
250
160
150
Approved fluids
-15 to +120
40
40
40
40
40
40
40
40
16/25
16/25
16/25
16/25
16/25
16/25
16/25
10
10
10
10
10
10
10
10
3500
3500
3500
3500
3500
3500
3500
3500
16/25
Motor
Mains connection 1~ [V/Hz]
(Permissible voltage tolerance 10%)
EN 61800-3
IP 55
IP 55
IP 55
IP 55
IP 55
IP 55
IP 55
IP 55
25
25
32
40
50
50
65
80
Connections
Victaulic-connections
Materials
Impellers
Stage chambers
Pump housing
1.4301/1.4404
EN-GJL-250/1.4404
Shaft
1.4301/1.4404
1.4057/1.4404
44
2..
4..
8..
16..-6
16..
32..
52..
Seal
EPDM
(EP 851)/Viton
Housing cover
EPDM
(EP 851)/Viton
1.4301/1.4404
Housing base
1.4301/1.4404
Mechanical seal
B-Carbon/Tungsten carbide
SiC/carbon
Pressure jacket
1.4301/1.4404
Bearing
Tungsten carbide
Pump base
Pump base (in contact with the flow medium)
Nasslufer-Pumpen
Materials (continued)
EN-GJL-250
-
EN-GJL-250/1.4408
Systeme
Pumpenmanagement
Trockenlufer-Pumpen
Note on materials:
1.4301 satisfies AISI 304, 1.4404 satisfies AISI 316L.
45
52..C
70..
95..
Condensate
Water-glycol mixture
(Up to 40% Vol. glycol / from 10% Vol.glycol performance verification required)
50
70
100
140
235
230
182
140
-15 to +120
-15 to +120
-15 to +120
-15 to +120
40
40
40
40
25
25
16/25
16/25
10
10
10
10
3500
3500
3500
3500
Approved fluids
IP 55
IP 55
IP 55
IP 55
65
80
100
100
Victaulic-connections
Impellers
1.4301
1.4301
1.4301
1.4301
Stage chambers
1.4301
1.4301
1.4301
1.4301
Pump housing
1.4301
1.4301
1.4301
1.4301
Shaft
1.4301
1.4301
1.4301
1.4301
Protection class
Connections
Materials
46
Seal
32..C
52..C
70..
95..
EPDM
EPDM
EPDM
EPDM
1.4301
1.4301
1.4301
1.4301
Nasslufer-Pumpen
Wilo-Multivert MVI
Materials (continued)
Housing cover
Housing base
1.4031/1.4404
Mechanical seal
Tungsten carbide/carbon
EPDM
Pressure jacket
1.4031/1.4404
Bearing
Tungsten carbide
Pump base
Pump base (in contact with the flow medium)
EN-GJL-250 KTL-coated
-
Systeme
Pumpenmanagement
Trockenlufer-Pumpen
Note on materials:
1.4301 satisfies AISI 304, 1.4404 satisfies AISI 316L.
47
Pump curves Wilo-Multivert MVI 1.., 2.., 4.., 8.., 16.., 16-6..
Wilo-Multivert MVI 102 up to MVI 116
240
Wilo-Multivert-MVI 102-116
MVI 116
60 Hz
220
MVI 114
200
180
MVI 112
160
MVI 110
140
H [m]
MVI 109
120
MVI 108
MVI 107
100
MVI 106
80
MVI 105
MVI 104
60
MVI 103
40
MVI 102
20
0
0
0.5
0.1
1.0
0.2
1.5
0.3
0.4
2.0
0.5
2.5
0.6
0.7
3.0
0.8
Q [m/h]
3.5
0.9
1.0
Q [l/s]
50
12
p
p [%]
40
10
8
30
6
20
10
0
NPSH
0
0.5
NPSH [m]
1.0
1.5
2.0
2.5
3.0
3.5
Q [m/h]
3.5
Q [m/h]
3.0
MVI 116
MVI 114
2.5
MVI 112
2.0
P2 [kW]
MVI 110
MVI 109
1.5
MVI 108
MVI 107
1.0
MVI 106
MVI 105
MVI 104
0.5
MVI 103
MVI 102
0.5
1.0
1.5
2.0
2.5
3.0
48
Pump curves Wilo-Multivert MVI 1.., 2.., 4.., 8.., 16.., 16-6..
Wilo-Multivert MVI 202 up to MVI 214
240
Wilo-Multivert-MVI 202-214
MVI 214
Nasslufer-Pumpen
60 Hz
220
200
MVI 212
MVI 211
180
MVI 210
160
140
H [m]
MVI 208
120
MVI 207
MVI 206
100
MVI 205
80
Systeme
MVI 204
60
MVI 203
40
MVI 202
20
1
0.2
2
0.4
3
0.6
50
0.8
4
1.0
5
1.2
1.4
Q [m/h]
Q [l/s]
1.6
40
p [%]
Trockenlufer-Pumpen
30
20
2
NPSH [m]
10
0
NPSH
0
Q [m/h]
Q [m/h]
4.0
MVI 214
3.5
MVI 211
2.5
MVI 210
P2 [kW]
MVI 212
3.0
MVI 208
2.0
MVI 207
MVI 206
1.5
MVI 204
0.5
MVI 203
MVI 202
Pumpenmanagement
MVI 205
1.0
49
Pump curves Wilo-Multivert MVI 1.., 2.., 4.., 8.., 16.., 16-6..
Wilo-Multivert MVI 402 up to MVI 414
240
Wilo-Multivert-MVI 402-414
MVI 414
60 Hz
220
200
MVI 412
180
MVI 411
MVI 410
160
140
H [m]
MVI 408
120
MVI 407
MVI 406
100
MVI 405
80
MVI 404
60
MVI 403
40
MVI 402
20
0
0
1
0.2
2
0.4
3
0.6
60
1.0
5
1.2
1.4
6
1.6
7
1.8
8
2.0
2.2
Q [m/h]
2.6 Q [l/s]
2.4
50
p [%]
0.8
40
30
20
2
10
0
NPSH [m]
NPSH
0
Q [m/h]
Q [m/h]
6
MVI 414
5
MVI 412
MVI 411
4
P2 [kW]
MVI 410
MVI 408
MVI 407
MVI 406
2
MVI 405
MVI 404
MVI 403
MVI 402
0
50
Pump curves Wilo-Multivert MVI 1.., 2.., 4.., 8.., 16.., 16-6..
Wilo-Multivert MVI 802 up to MVI 811
200
Wilo-Multivert-MVI 802-811
MVI 811
Nasslufer-Pumpen
60 Hz
180
MVI 810
160
MVI 808
140
MVI 807
H [m]
120
MVI 806
100
MVI 805
80
MVI 804
Systeme
60
MVI 803
40
MVI 802
0.5
1.5
2.0
10
2.5
12
3.0
14
3.5
16
4.0
4.5
18
Q [m/h]
5.0
Q [l/s]
6
60
50
p [%]
1.0
5
4
40
30
20
NPSH
10
0
NPSH [m]
Trockenlufer-Pumpen
20
10
12
14
16
18
Q [m/h]
18
Q [m/h]
8
MVI 811
7
MVI 810
6
MVI 808
P2 [kW]
5
MVI 807
4
MVI 806
MVI 805
3
MVI 804
2
MVI 803
MVI 802
10
12
14
16
Pumpenmanagement
51
Pump curves Wilo-Multivert MVI 1.., 2.., 4.., 8.., 16.., 16-6..
Wilo-Multivert MVI 1602-6 up to MVI 1606-6
110
Wilo-Multivert-MVI 1602/6-1606/6
60 Hz
MVI 1606/6
100
90
MVI 1605/6
80
70
MVI 1604/6
H [m]
60
MVI 1603/6
50
40
MVI 1602/6
30
20
10
10
12
14
16
70
18
20
22
24
26
Q [m/h]
28
Q [l/s]
60
p [%]
50
40
30
20
NPSH
10
0
10
12
14
16
18
20
22
24
26
28
Q [m/h]
28
Q [m/h]
8
7
6
5
4
3
2
1
0
NPSH [m]
7
MVI 1606/6
6
MVI 1605/6
5
P2 [kW]
MVI 1604/6
4
MVI 1603/6
3
MVI 1602/6
2
10
12
14
16
18
20
22
24
26
52
Wiring diagram, motor data Wilo-Multivert MVI 1.., 2.., 4.., 8.., 16.., 16-6..
W2
U2
V2
U1
V1
W1
L1
L2
L3
W2
U2
V2
U1
V1
W1
3~380 V
3~220 V
V2
W1
U2
V1
W2
U1
Nasslufer-Pumpen
Terminal diagram
3~380 V
U2
W2
1~220 V
V1
U1
L
W2
U2
U1
V1
0
Systeme
1~220 V
Motor data
Nominal current IN
3~220 V
3~380 V
[kW]
[A]
MVI 102
0.37
1.52
0.88
MVI 103
0.55
2.2
1.27
MVI 104
0.75
3.0
1.73
MVI 105
1.1
4.2
2.4
MVI 106
1.1
4.2
2.4
MVI 107
1.5
5.4
3.2
MVI 108
1.5
5.4
3.2
MVI 109
1.85
6.6
3.8
MVI 110
1.85
6.6
3.8
MVI 112
2.2
7.9
4.6
MVI 114
3.0
10.2
6.3
MVI 116
3.0
10.2
6.3
MVI 202
0.55
3.6
2.2
1.25
MVI 203
0.75
5.5
3.0
1.8
MVI 204
1.1
7.0
4.2
2.4
MVI 205
1.5
9.5
5.4
3.2
MVI 206
1.85
6.6
3.8
MVI 207
2.2
7.9
4.6
MVI 208
2.2
7.9
4.5
MVI 210
3.0
10.2
5.9
MVI 211
3.0
10.2
5.9
MVI 212
3.7
12.5
7.2
MVI 214
3.7
12.5
7.2
on request
Trockenlufer-Pumpen
1~220 V
Nominal output P2
Pumpenmanagement
Wilo-Multivert
53
Wiring diagram, motor data Wilo-Multivert MVI 1.., 2.., 4.., 8.., 16.., 16-6..
Motor data
Wilo-Multivert
Nominal output P2
Nominal current IN
1~220 V
3~220 V
[kW]
54
3~380 V
[A]
MVI 402
0.75
5.5
3.0
1.8
MVI 403
1.1
7.0
4.2
2.4
MVI 404
1.5
9.5
5.4
3.2
MVI 405
1.85
6.6
3.8
MVI 406
2.2
7.9
4.6
MVI 407
3.0
10.2
5.9
MVI 408
3.0
10.2
5.9
MVI 410
4.0
13.5
7.8
MVI 411
4.0
13.5
7.8
MVI 412
5.5
11.2
MVI 414
5.5
11.2
MVI 802
1.5
9.5
5.4
3.2
MVI 803
2.2
7.9
4.6
MVI 804
3.0
10.2
5.9
MVI 805
3.7
12.5
7.2
MVI 806
4.0
13.5
7.8
MVI 807
5.5
11.2
MVI 808
5.5
11.2
MVI 810
7.5
15.0
MVI 811
7.5
15.0
MVI 1602-6
2.2
7.9
4.6
MVI 1603-6
3.7
12.5
7.2
MVI 1604-6
5.5
11.2
MVI 1605-6
5.5
11.2
MVI 1606-6
7.5
15.0
Dimensions, weights Wilo-Multivert MVI 1.., 2.., 4.., 8.., 16.., 16-6..
Dimension drawings
Wilo-Multivert MVI 102 up to 116
Nasslufer-Pumpen
Rp1/DN25
75
Rp1/DN25
PN 16
PN 16
4x 12
50
50
4x 12
180
180
212
212
85
DN 25
85
DN 25
PN 25
4x14
4x14
PN 25
h2
4x 12
75
75
4x 12
4x 12
100
100
4x 12
Systeme
Victaulic
Trockenlufer-Pumpen
42,4
50
42,4
100
Victaulic
34,4
180
212
212
50
h2
180
X
M
75
Rp11/4/DN32
75
Rp1/DN25
PN 16
PN 16
85
85
DN 25
DN 25
PN 25
PN 25
4x14
4x14
4x 12
34,4
34,4
42,4
100
Victaulic
Pumpenmanagement
4x 12
Victaulic
50
100
E
180
212
50
42,4
180
212
75
4x 12
h2
75
h2
4x 12
180
212
180
212
50
4x 12
50
4x 12
55
Dimensions, weights Wilo-Multivert MVI 1.., 2.., 4.., 8.., 16.., 16-6..
Dimension drawings
Wilo-Multivert MVI 1602-6 up to 1606-6
X
M
100
Rp2 /DN50
90
4x 12
PN 16
215
252
125
H
DN 50
PN 25
4x18
90
h2
4x 12
130
E
56
4x 12
52,3
90
60,3
215
252
Victaulic
Dimensions, weights Wilo-Multivert MVI 1.., 2.., 4.., 8.., 16.., 16-6..
Dimensions, weights
Version PN 16 Oval flange
1~220 V
H2
3~380 V
M
1~220 V
Weight 1)
X
3~380 V
1~220 V
3~380 V
1~220 V
[mm]
3~380 V
[kg]
MVI 102
528
305
140
118
18.9
MVI 103
528
305
140
118
19.6
MVI 104
558
315
170
127
22.6
MVI 105
578
335
170
127
24.4
MVI 106
598
335
170
127
25.1
651
385
MVI 107
MVI 108
on
request
193
on
request
193
151
on
request
151
30.1
on
request
692
425
MVI 109
692
426
193
151
33.4
MVI 110
712
445
193
151
33.0
MVI 112
29.2
MVI 114
35.6
MVI 116
1) incl.
Nasslufer-Pumpen
31.3
Systeme
Wilo-Multivert
Dimensions, weights
1~220 V
H2
3~380 V
M
1~230 V
Weight 1)
X
3~380 V
1~220 V
3~380 V
1~220 V
[mm]
3~380 V
[kg]
MVI 102
552
330
140
118
20.0
MVI 103
552
330
140
118
20.7
MVI 104
548
340
170
127
23.7
MVI 105
604
360
170
127
25.6
MVI 106
624
380
170
127
26.3
MVI 107
676
410
193
151
MVI 108
on
request
on
request
Trockenlufer-Pumpen
193
on
request)
151
on
request
31.2
716
450
MVI 109
716
450
193
151
32.5
32.3
MVI 110
736
470
193
151
34.1
MVI 112
776
510
193
151
38.2
MVI 114
805
510
217
160
44.3
MVI 116
855
560
217
160
45.7
Wilo-Multivert
Pumpenmanagement
1) without packing
57
Dimensions, weights Wilo-Multivert MVI 1.., 2.., 4.., 8.., 16.., 16-6..
Dimensions, weights
Wilo-Multivert
Version PN 25 Victaulic
H
1~220V
H2
3~380 V
1~220 V
X
3~380 V
1~220 V
Weight
3~380 V
3~380 V
[mm]
[kg]
MVI 102
552
330
140
118
20.0
MVI 103
552
330
140
118
20.7
MVI 104
584
330
170
127
23.7
MVI 105
604
370
170
127
25.6
MVI 106
624
380
170
127
26.3
676
400
151
31.2
MVI 107
on
request
MVI 108
193
on
request
on
request
716
440
151
32.5
MVI 109
716
440
193
193
151
32.3
MVI 110
736
460
193
151
34.1
MVI 112
776
500
193
151
38.2
MVI 114
805
550
217
160
44.3
MVI 116
855
590
217
160
45.7
Dimensions, weights
Wilo-Multivert
H
1~220V
H2
3~380 V
M
1~220 V
Weight 2)
3~380 V
1~220 V
3~380 V
1~220 V
[mm]
3~380 V
[kg]
MVI 202
204
519
481.5
296.5
140
140
107
118
18.3
17.4
MVI 203
204
522
550
306.5
162
170
121
127
20.5
20.4
MVI 204
204
546
574
330.5
162
170
121
127
22.8
22.2
MVI 205
204
610
631
364.5
182
193
131
151
31.2
27.4
MVI 206
204
655
388.5
193
151
28.8
MVI 207
204
679
412.5
193
151
31.4
MVI 208
204
703
436.5
193
151
32.0
MVI 210
MVI 212
MVI 214
1) Dimensions incl.
without packing
Dimensions, weights
Wilo-Multivert
H
1~220 V
H2
3~380 V
M
1~220 V
Weight 1)
3~380 V
1~220 V
3~380 V
1~220 V
[mm]
[kg]
MVI 202
250
544
507
321.5
140
140
107
118
19.6
18.7
MVI 203
250
546
575
331.5
162
170
121
127
21.8
21.7
250
571
599
355.5
162
170
121
127
24.1
23.5
MVI 204
1) without
58
3~380 V
packing
Dimensions, weights Wilo-Multivert MVI 1.., 2.., 4.., 8.., 16.., 16-6..
Dimensions, weights
Version PN 25 Round flange
E
H
1~220 V
H2
3~380 V
M
1~220 V
Weight 1)
3~380 V
1~220 V
3~380 V
1~220 V
[mm]
Nasslufer-Pumpen
Wilo-Multivert
3~380 V
[kg]
MVI 205
250
634
656
389.5
182
193
131
151
33.0
28.7
MVI 206
250
680
403.5
193
151
30.1
MVI 207
250
704
427.5
193
151
32.7
MVI 208
250
728
461.5
193
151
33.3
MVI 210
250
814
509.5
217
160
39.2
MVI 211
250
862
557.5
217
160
41
MVI 212
250
862
605.5
217
160
50
MVI 214
250
910
687.5
217
160
51.3
Systeme
1) without packing
Dimensions, weights
Version Victaulic 3~380 V
E
H2
Weight
[mm]
[kg]
MVI 202
210
506.5
321.5
140
118
18.7
MVI 203
210
575
331.5
170
127
21.7
MVI 204
210
599
355.5
170
127
23.5
MVI 205
210
656
389.5
193
151
20.7
MVI 206
210
680
413.5
193
151
30.1
MVI 207
210
704
437.5
193
151
32.7
MVI 208
210
728
461.5
193
151
33.3
MVI 210
210
814.5
519.5
217
160
39.2
MVI 212
210
862.5
567.5
217
160
50.0
MVI 214
210
910.5
615.5
217
160
51.3
Trockenlufer-Pumpen
Wilo-Multivert
H2
1~220V
3~380 V
M
1~220 V
Weight 2)
3~380 V
1~220 V
3~380 V
1~220 V
[mm]
3~380 V
[kg]
MVI 402
204
511.5
540
296.5
162
170
121
127
19.7
18.8
MVI 403
204
521.5
550
306.5
162
170
121
127
27.2
22
MVI 404
204
585.5
607
340.5
182
193
131
151
31.1
23.5
MVI 405
204
631
364.5
193
151
24.4
MVI 406
204
655
388.5
193
151
29
MVI 407
204
717.5
422.5
217
160
29.7
MVI 408
204
741.5
446.5
217
160
30.5
MVI 410
1) Dimensions
2) incl. mating
Pumpenmanagement
Wilo-Multivert
Dimensions, weights
59
Dimensions, weights Wilo-Multivert MVI 1.., 2.., 4.., 8.., 16.., 16-6..
Dimensions, weights
Wilo-Multivert
H
1~220V
H2
3~380 V
M
1~220 V
Weight 2)
3~380 V
1~220 V
3~380 V
1~220 V
[mm]
3~380 V
[kg]
MVI 412
MVI 414
1) Dimensions incl.
without packing
Dimensions, weights
Wilo-Multivert
H2
1~220 V
3~380 V
M
1~220 V
Weight 1)
3~380 V
1~220 V
3~380 V
1~220 V
[mm]
3~380 V
[kg]
MVI 402
250
536.5
565
321.5
162
170
121
127
21
20.9
MVI 403
250
346.5
575
331.5
162
170
121
127
23.5
22.9
MVI 404
250
610.5
632
365.5
182
193
131
151
32.4
28.1
MVI 405
250
650
389.5
193
151
29.5
MVI 406
250
680
413.5
193
151
32.1
MVI 407
250
742
447.5
217
160
37.4
MVI 408
250
766
471.5
217
160
38.0
MVI 410
250
814
519.5
217
160
48.2
MVI 411
250
862
567.5
217
160
50.1
MVI 412
250
892
567.5
235
168
54.1
250
940
615.5
235
168
55.3
MVI 414
1) without
packing
Dimensions, weights
Wilo-Multivert
H2
[mm]
60
Weight
[kg]
MVI 402
210
565
321.5
170
127
20.9
MVI 403
210
575
331.5
170
127
22.9
MVI 404
210
632
365.5
193
151
28.1
MVI 405
210
656
389.5
193
151
29.5
MVI 406
210
680
413.5
193
151
32.1
MVI 407
210
742.5
447.5
217
160
37.4
MVI 408
210
766.5
471.5
217
160
38
MVI 410
210
814.5
519.5
217
160
48.2
MVI 412
210
892.5
567.5
235
168
54.1
MVI 414
210
940.5
615.5
235
168
55.3
Dimensions, weights Wilo-Multivert MVI 1.., 2.., 4.., 8.., 16.., 16-6..
Dimensions, weights
Version PN 16 Oval flange
E1)
H
1~220V
H2
3~380 V
M
1~220 V
Weight 2)
3~380 V
1~220 V
3~380 V
1~220 V
[mm]
3~380 V
[kg]
MVI 802
250
588
610
343.5
182
193
131
151
32.6
28.3
MVI 803
250
640
373.5
193
151
31.8
MVI 804
250
708
413.5
217
160
37.2
MVI 805
250
738
443.5
217
160
46.2
MVI 806
250
768
473.5
217
160
47.6
MVI 807
250
828
503.5
235
168
52.4
MVI 808
858
533.5
235
168
53.1
MVI 810
MVI 811
2) incl. mating
Systeme
1) Dimensions
Nasslufer-Pumpen
Wilo-Multivert
Dimensions, weights
Version PN 25 Round flange
H
1~220 V
H2
3~380 V
M
1~220 V
Weight 1)
3~380 V
1~220 V
3~380 V
1~220 V
[mm]
3~380 V
[kg]
MVI 802
280
588.5
610
343.5
182
193
131
151
38.4
36.6
MVI 803
280
640
373.5
193
151
40.2
MVI 804
280
708
413.5
217
160
48.2
MVI 805
280
738
443.5
217
160
55.2
MVI 806
280
768
473.5
217
160
56.2
MVI 807
280
828
503.5
235
168
61.2
MVI 808
280
858
533.5
235
168
61.9
MVI 810
280
1009
613
265
179
84.7
MVI 811
280
1069
673
265
179
86.1
Trockenlufer-Pumpen
Wilo-Multivert
Pumpenmanagement
1) without packing
61
Dimensions, weights Wilo-Multivert MVI 1.., 2.., 4.., 8.., 16.., 16-6..
Dimensions, weights
Wilo-Multivert
H
1~220V
H2
Weight
3~380V
[mm]
[kg]
MVI 802
261
610
343.5
193
151
28.6
MVI 803
261
640
373.5
193
151
32.2
MVI 804
261
708
413.5
217
160
37.5
MVI 805
261
738
443.5
217
160
47.2
MVI 806
261
768
473.5
217
160
48
MVI 807
261
828
503.5
235
168
52.7
MVI 808
261
858
533.5
235
168
53.4
MVI 810
261
1009
613
265
179
74.7
MVI 811
261
1069
673
265
179
76.1
E1)
Dimensions, weights
Wilo-Multivert
1~220V
3~380 V
M
1~220 V
Weight 2)
3~380 V
1~220 V
3~380 V
1~220 V
[mm]
3~380 V
[kg]
MVI 1602-6
250
663
396.5
193
151
33.2
MVI 1603-6
250
712
417.5
217
160
48.1
MVI 1604-6
250
780
455.5
235
168
53.3
MVI 1605-6
250
818
493.5
235
168
54.5
250
942
551
265
179
74.7
MVI 1606-6
1) Dimensions incl.
without packing
Dimensions, weights
Wilo-Multivert
H
1~220 V
H2
3~380 V
M
1~220 V
Weight 1)
3~380 V
1~220 V
3~380 V
1~220 V
[mm]
MVI 1602-6
300
636
369.5
193
151
33.2
MVI 1603-6
300
712
417.5
217
160
48.1
MVI 1604-6
300
780
455.5
235
168
53.3
MVI 1605-6
300
818
493.5
235
168
54.5
MVI 1606-6
300
947
551
265
179
74.7
1) without
62
3~380 V
[kg]
packing
260
Nasslufer-Pumpen
Wilo-Multivert-MVI 1602-1610
MVI 1610
60 Hz
240
MVI 1609
220
MVI 1608
200
180
MVI 1607
160
MVI 1606
H [m]
140
MVI 1605
100
MVI 1604
80
MVI 1603
Systeme
120
60
MVI 1602
40
10
12
14
16
4
70
18
20
22
24
26
28 Q [m/h]
Q [l/s]
60
p [%]
50
40
30
20
NPSH
10
0
10
12
14
16
18
20
22
24
26
28 Q [m/h]
26
28 Q [m/h]
18
16
14
12
10
8
6
4
2
0
NPSH [m]
Trockenlufer-Pumpen
20
20
18
MVI 1609
14
MVI 1608
MVI 1610
16
MVI 1607
P2 [kW]
12
MVI 1606
10
MVI 1605
8
MVI 1604
6
MVI 1603
MVI 1602
10
12
14
16
18
20
22
24
Pumpenmanagement
63
240
60 Hz
220
MVI 3208 C
200
180
160
MVI 3206
140
H [m]
MVI 3205
120
MVI 3204
100
80
MVI 3203
60
MVI 3202
40
20
0
0
10
2
20
4
30
6
70
40
10
50
12
14
Q [m/h]
Q [l/s]
60
p [%]
50
40
30
20
NPSH
10
0
10
20
30
40
50
Q [m/h]
50
Q [m/h]
18
16
14
12
10
8
6
4
2
0
NPSH [m]
MVI 3209 C
30
MVI 3208 C
25
P2 [kW]
20
MVI 3206
MVI 3205
15
MVI 3204
MVI 3203
10
MVI 3202
5
10
20
30
40
64
Nasslufer-Pumpen
240
MVI 5208 C
220
200
MVI 5207 C
180
MVI 5206 C
160
MVI 5205
H [m]
140
120
MVI 5204
100
Systeme
MVI 5203
80
MVI 5202
60
40
p [%]
0
70
60
50
40
30
20
10
0
10
2
20
4
30
6
40
10
50
12
14
60
16
Q [m/h]
70
18
20
22
Q [l/s]
6
4
NPSH
10
20
30
40
50
60
70
Q [m/h]
70
Q [m/h]
NPSH [m]
Trockenlufer-Pumpen
20
35
MVI 5208 C
30
25
MVI 5207 C
MVI 5206 C
P2 [kW]
MVI 5205
20
MVI 5204
15
MVI 5203
10
MVI 5202
10
20
30
40
50
60
Pumpenmanagement
65
W2
U2
V2
U1
V1
W1
L1
L2
L3
W2
U2
V2
U1
V1
W1
L1
L2
3~380 V
W2
U1
U2
V1
V2
W1
3~380 V
3~220 V
L3
Motor data
Wilo-Multivert
Nominal output P2
Nominal current IN
3~220 V
[kW]
66
3~380 V
[A]
MVI 1602
3.7
7.2
MVI 1603
5.5
11.2
MVI 1604
7.5
15
MVI 1605
9.0
16.9
MVI 1606
11.0
20.4
MVI 1607
15.0
28
MVI 1608
15.0
28
on request
MVI 1609
18.5
MVI 1610
18.5
35
MVI 3202
7.5
15
MVI 3203
11
20.4
MVI 3204
15
28
MVI 3205
18.5
35
MVI 3206
22
41
MVI 3208 C
30
60
MVI 3209 C
30
60
35
Nominal current IN
3~220 V
[kW]
MVI 5202
3~380 V
Nasslufer-Pumpen
Wilo-Multivert
[A]
-
16.9
15
28
MVI 5204
18.5
35
MVI 5205
22
41
MVI 5206 C
30
60
MVI 5207 C
30
60
MVI 5208 C
37
74.7
Pumpenmanagement
Trockenlufer-Pumpen
Systeme
MVI 5203
67
195
215
195
4 x 14
h2
h2
4 x 14
105
145
DN 65
90
125
DN 50
4 x 18
239
235
194
252
320
300
220
220
220
4 x 14
h2
h2
4 x 14
260
262
320
68
105
DN 80
160
120
145
DN 65
260
260
320
MVI 1602
724
429
217
160
73
MVI 1603
754
429
235
168
77.3
MVI 1604
878
484
265
179
99.3
MVI 1605
917
518
300
179
111.3
MVI 1606
951
552
300
179
113.3
MVI 1607
MVI 1608
MVI 1609
MVI 1610
MVI 3202
888
493
265
179
4x18
108.5
MVI 3203
953
554
300
179
4x18
116.3
MVI 3204
1122
645
325
208
4x18
152.9
MVI 3205
1216
768
325
235
4x18
173.2
MVI 3206
MVI 3208 C
MVI 3209 C
892
493
300
179
118.5
MVI 5203
1060
584
325
208
149.7
MVI 5204
1216
645
325
235
167.9
MVI 5205
1287
768
370
248
197.2
MVI 5206 C
MVI 5207 C
MVI 5208 C
MVI 5202
Pumpenmanagement
52..
[kg]
Nasslufer-Pumpen
[mm]
32..,
Weight
Systeme
Version PN 16
X
Trockenlufer-Pumpen
Wilo-Multivert
69
70
H2
MVI 1602
724
429
M
[mm]
190
MVI 1603
754
429
MVI 1604
878
484
MVI 1605
917
MVI 1606
MVI 1607
MVI 1608
Version PN 25
X
160
Weight
[kg]
73
215
168
77.3
235
179
99.3
518
235
179
111.3
952
522
235
179
113.3
1128
652
265
208
145
1128
652
265
208
145.7
MVI 1609
1216
720
300
235
164.4
MVI 1610
1216
720
300
235
164.7
MVI 3202
870
475
265
179
8x18
84
MVI 3203
920
521
300
179
8x18
86
MVI 3204
1073
597
325
208
8x18
109
MVI 3205
1184
689
325
235
8x18
128
MVI 3206
1208
689
370
248
8x18
128
MVI 3208 C
1498
899
415
255
8x18
163
MVI 3209 C
1544
945
415
255
8x18
163
MVI 5202
892
495
300
179
118.5
MVI 5203
1060
584
325
208
149.7
MVI 5204
1140
645
325
235
167.9
MVI 5205
1287
768
370
248
197.2
MVI 5206
1485
886
415
255
264.4
MVI 5207 C
1607
1008
415
255
269.7
MVI 5208 C
1629
1008
415
275
289.7
MVI 7005
Nasslufer-Pumpen
180
/1
MVI 7005
/2
160
MVI 7004
140
MVI 7004
/1
MVI 7004/2
120
H [m]
MVI 7003
MVI 7003/1
100
MVI 7003/2
80
MVI 7002
MVI 7002/1
Systeme
60
MVI 7002/2
MVI 7001
40
MVI 7001/1
20
20
5
40
60
10
80
15
80
20
120 Q [m/h]
100
25
30
Q [l/s]
p [%]
60
40
20
NPSH
0
20
40
60
80
120 Q [m/h]
100
Trockenlufer-Pumpen
16
14
12
10
8
6
4
2
0
NPSH [m]
50
MVI 7005/1
MVI 7005/2
MVI 7004
40
MVI 7004/1
MVI 7004/2
MVI 7003
P2 [kW]
30
MVI 7003/1
MVI 7003/2
20
MVI 7002
MVI 7002/1
MVI 7002/2
10
MVI 7001
MVI 7001/1
20
40
60
80
100
120 Q [m/h]
Pumpenmanagement
71
W2
U1
U2
V1
V2
W1
3~380 V
Motor data
Wilo-Multivert
Nominal output P2
Nominal current IN
3~220 V, 60 Hz
[kW]
72
3~380 V, 60 Hz
[A]
MVI 7001/1
7.5
15
MVI 7001
11
20.4
MVI 7002/2
15
30
MVI 7002/1
18.5
38.5
MVI 7002
22
43.5
MVI 7003/2
22
43.5
MVI 7003/1
30
60
MVI 7003
30
60
MVI 7004/2
37
74.7
MVI 7004/1
37
74.7
MVI 7004
45
97
MVI 7005/2
45
97
MVI 7005/1
45
97
280
Nasslufer-Pumpen
4 x 14
h2
199
Systeme
45
100
180
264
350
380
Dimensions, weights
H2
Version PN 25
K
[mm]
Weight1)
h2
[kg]
[mm]
Weight 1)
[kg]
MVI 7001/1
920
559
279
182
8 x 19
136
920
559
279
182
8x23
136
MVI 7001
955
559
280
182
8 x 19
126
955
672
280
182
8x23
126
MVI 7002/2
1233
757
325
208
8 x 19
169
1233
757
325
208
8x23
169
MVI 7002/1
1252
757
325
235
8 x 19
184
1252
757
325
235
8x23
184
MVI 7002
1276
757
370
249
8 x 19
207
1276
757
370
249
8x23
207
MVI 7003/2
1276
842
370
249
8 x 19
210
1276
842
370
249
8x23
210
MVI 7003/1
1441
842
415
255
8 x 19
257
1441
842
415
255
8x23
257
MVI 7003
1441
842
415
255
8 x 19
257
1441
842
415
255
8x23
257
MVI 7004/2
1548
927
415
275
8 x 19
283
1548
927
415
275
8x23
283
MVI 7004/1
1548
927
415
275
8 x 19
283
1548
927
415
275
8x23
283
MVI 7004
1639
927
456
275
8 x 19
313
1639
927
456
275
8x23
313
MVI 7005/2
1639
1012
456
275
8x23
317
MVI 7005/1
1639
1012
456
275
8x23
317
packing
Pumpenmanagement
1) without
Trockenlufer-Pumpen
Version PN 16
Wilo-Multivert
73
140
MVI 9
503
MVI 9
503/1
120
MVI 95
03/2
100
MVI 950
H [m]
MVI 9502
80
/1
MVI 9502/2
60
MVI 9501
40
MVI 9501/1
20
0
0
20
5
40
10
60
15
80
20
100
25
120
30
Q [m/h]
140
35
Q [l/s]
40
80
p
p [%]
60
40
20
NPSH
0
20
40
60
80
100
120
Q [m/h]
140
20
18
16
14
12
10
8
6
4
2
0
NPSH [m]
50
MVI 9503
MVI 9503/1
40
MVI 9503/2
MVI 9502
30
P2 [kW]
MVI 9502/1
MVI 9502/2
20
MVI 9501
MVI 9501/1
10
20
40
60
80
100
120
140
Q [m/h]
74
U2
V1
V2
W1
3~380 V
Systeme
W2
U1
Nasslufer-Pumpen
Motor data
Wilo-Multivert
Nominal output P2
Nominal current IN
[kW]
[A]
15
30
18.5
35.5
MVI 9502/2
22
43.5
MVI 9502/1
30
60
MVI 9502
37
74.7
MVI 9503/2
37
74.7
MVI 9503/1
45
97
MVI 9503
45
97
MVI 9501/1
Pumpenmanagement
MVI 9501
Trockenlufer-Pumpen
3~380 V, 60 Hz
75
280
4 x 14
h2
199
45
100
180
264
350
380
Dimensions, weights
Wilo-Multivert
Version PN 16
H
H2
Version PN 25
K
[mm]
76
Weight
H2
[kg]
[mm]
MVI 9501/1
1161
685
325
308
8 x 19
147.2
1161
625
MVI 9501
1161
685
325
235
8 x 19
160.2
1180
685
325
MVI 9502/2
1302
783
370
249
8 x 19
208
1302
783
370
MVI 9502/1
1392
783
415
255
8 x 19
255
1382
783
415
MVI 9502
1382
783
415
275
8 x 19
255
1382
783
415
MVI 9503/2
1502
881
370
275
8 x 19
281.5
1502
881
MVI 9503/1
1508
881
415
275
8 x 19
311.5
1508
MVI 9503
1508
881
415
275
8 x 19
311.5
1508
325
Weight
[kg]
208
8x23
165
235
8x23
180
249
8x23
208
255
8x23
255
275
8x23
255
370
275
8x23
321.5
881
415
275
8x23
321.5
881
415
275
8x23
321.5
Nasslufer-Pumpen
Material
Seals
EPDM
Viton
Threaded connection
Oval flange
Round flange
Systeme
Hydraulic connection
Motor versions
optional
3~230 V, 50 Hz
3~400 V, 50 Hz
3~500 V, 50 Hz
1~110 V, 60 Hz
1~220 V, 60 Hz
3~380 V, 60 Hz
3~400 V, 60 Hz
3~440 V, 60 Hz
3~460 V, 60 Hz
3~480 V, 60 Hz
IP 54
IP 55
Ex-protected motors
1~230 V, 50 Hz
Trockenlufer-Pumpen
Pumpenmanagement
Individual motors
(only 1~220 V)
77
optional
Mechanical seals
Tungsten carbide/carbon
SiC/carbon
optional
optional
SiC/SiC
optional
WRAS
78
3..
5..
9..
Condensate
Water-glycol mixture
(Up to 40% Vol. glycol / from 10% Vol.glycol performance verification required)
10
18
126
129
113
67
-15 to +90
-15 to +90
-15 to +90
-15 to +90
40
40
40
40
10
10
10/16
10/16
3500
3500
3500
3500
Nasslufer-Pumpen
Approved fluids
Trockenlufer-Pumpen
Systeme
Motor
Mains connection 1~ [V/Hz]
(Permissible voltage tolerance 10%)
220/60 or 230/50
230/50 or 220/60
400/50 Y or 380/60 Y
Insulation class
IP 54
IP 54
IP 54
IP 54
Victaulic-connections
1.4301
1.4301
1.4301
1.4301
Protection class
Connections
Materials
Impellers
= not available
Pumpenmanagement
= available,
79
Stage chambers
1..
3..
5..
9..
1.4301
1.4301
1.4301
1.4301
Materials (continued)
Pump housing
Shaft
1.4404
1.4404
1.4404
1.4404
Seal
EPDM
EPDM
EPDM
EPDM
Housing cover
Housing base
Mechanical seal
SiC/carbon
SiC/carbon
SiC/carbon
SiC/carbon
Pressure jacket
Tungsten carbide
Tungsten carbide
Tungsten carbide
Tungsten carbide
Bearing
Pump base
= available,
= not available
80
140
140
Wilo-Multivert-MVIL 102-109
109
120
120
107
306
80
305
H [m]
H [m]
100
106
80
105
60
304
60
104
303
103
40
60 Hz
307
108
100
Wilo-Multivert-MVIL 302-308
308
60 Hz
Nasslufer-Pumpen
40
302
102
0.2
0.5
2.0
0.4
1.0
2.5
0.6
1.5
1.4
Q [l/s]
0.8
2.0
2.5
Q [m/h]
3.0
Q [m/h]
3.0
0
10
8
6
4
2
0
50
40
30
20
10
0
0.2
0.4
0.6
0.8
4
1.0
1.4
108
Q [l/s]
NPSH
0
Q [m/h]
10
8
6
4
2
0
8
6
4
2
0
308
2.0
107
0.6
104
105
1.5
306
1.0
304
305
103
0.4
303
0.5
102
0.2
0
0.5
1.0
1.5
2.0
2.5
Q [m/h]
3.0
302
0
70
904
Wilo-Multivert-MVIL 502-507
60 Hz
100
Q [m/h]
120
507
Trockenlufer-Pumpen
106
P2 [kW]
P2 [kW]
307
0.8
Wilo-Multivert-MVIL 902-904
60 Hz
60
506
903
50
505
80
40
H [m]
504
H [m]
1.6
1.0
Q [m/h]
5
1.2
2.5
109
1.2
60
902
503
30
502
20
p [%]
50
40
30
20
10
0
1.5
Systeme
1.0
NPSH [m]
0.5
p [%]
NPSH [m]
20
NPSH [m]
20
40
20
2
0.4
3
0.8
1.2
6
1.6
60
12
40
20
NPSH
Q [m/h]
3.0
0.5
1.0
6
1.5
8
2.0
10
2.5
12
3.0
3.5
14
4.0
Q [m/h]
Q [l/s]
p
NPSH
0
10
12
14
Q [m/h]
12
14
Q [m/h]
3.0
507
2.5
506
P2 [kW]
2.0
1.5
505
504
1.0
503
0.5
502
Q [m/h]
2.5
904
2.0
903
1.5
Pumpenmanagement
80
60
40
20
0
P2 [kW]
p [%]
Q [m/h]
2.4 Q [l/s]
2.0
p [%]
NPSH [m]
10
902
1.0
0.5
0.0
10
81
Wiring diagram, motor data Wilo-Multivert MVIL 1.., 3.., 5.., 9..
Terminal diagram
1~220 V
3~380 V
W2
U2
V2
U1
V1
W1
W2
W1
U1
L
L1
L2
L3
3~220 V
W2
U2
V2
U1
V1
W1
Motor data
Wilo-Multivert
Nominal output P2
1~220 V, 60 Hz
Nominal current IN
3~380 V, 60 Hz
1~220 V, 60 Hz
[kW]
82
3~220 V, 60 Hz
3~380 V, 60 Hz
[A]
MVIL 102
0.55
0.37
3.7
1.5
0.9
MVIL 103
0.55
0.55
3.7
2.6
1.5
MVIL 104
0.75
0.75
5.6
3.2
1.8
MVIL 105
0.75
0.75
5.6
3.2
1.8
MVIL 106
1.1
1.1
7.2
3.9
2.2
MVIL 107
1.1
1.1
7.2
3.9
2.2
MVIL 108
1.1
1.5
9.8
5.5
3.2
MVIL 109
1.5
1.5
9.8
5.5
3.2
MVIL 302
0.55
0.55
3.7
2.6
1.5
MVIL 303
0.75
0.75
5.3
3.2
1.8
MVIL 304
1.1
1.1
6.8
3.9
2.2
MVIL 305
1.5
1.5
9.2
5.5
3.2
MVIL 306
1.5
1.5
9.2
5.5
3.2
MVIL 307
1.85
7.2
4.2
MVIL 308
2.2
8.1
4.7
MVIL 502
0.75
0.75
5.6
3.2
1.8
MVIL 503
1.1
1.1
7.2
3.9
2.2
MVIL 504
1.5
1.5
9.8
5.5
3.2
MVIL 505
1.85
7.2
4.2
MVIL 506
2.2
8.1
4.7
MVIL 507
2.5
9.7
5.6
MVIL 902
0.75
0.75
9.8
5.5
3.2
MVIL 903
1.1
7.2
4.2
MVIL 904
1.5
9.7
5.6
Nasslufer-Pumpen
75
100
D
Systeme
M12
4x 14
80
50
4x 14
19,5
M10
180
100
215
212
130
162
252
187
204
Trockenlufer-Pumpen
248
Dimensions, weights
H
1~220 V
3~380 V
1~220 V
X
3~380 V
Weight
1~220 V
3~380 V
1~220 V
[mm]
3~380 V
[kg]
MVIL 102
1"
418
418
121
121
117
110
17.5
17.5
MVIL 103
1"
418
418
121
121
117
110
17.8
17.8
MVIL 104
1"
425
425
136
136
125
118
18.1
20.9
MVIL 105
1"
445
445
136
136
125
118
18.4
20.4
MVIL 106
1"
472
465
156
136
133
118
18.7
20.7
MVIL 107
1"
452
485
156
136
133
118
21.9
23.9
MVIL 108
1"
532
532
156
156
133
126
22.2
24.2
MVIL 109
1"
532
532
156
156
133
126
25.5
24.5
MVIL 302
1"
410
410
121
121
117
110
17.6
17.6
MVIL 303
1"
417
417
136
136
125
118
17.9
17.9
MVIL 304
1"
448
441
156
136
133
118
21.3
21.3
MVIL 305
1"
472
472
156
156
133
126
21.7
21.7
MVIL 306
1"
496
496
156
156
133
126
23.4
20.4
MVIL 307
1"
520
156
126
22.4
MVIL 308
1"
591
193
148
25.7
Dia. D
Pumpenmanagement
Wilo-Multivert...
83
Dia. D
1~220 V
3~380 V
1~220 V
X
3~380 V
Weight
1~220 V
3~380 V
1~220 V
[mm]
84
3~380 V
[kg]
MVIL 502
1 1/4"
417
417
136
136
125
118
17.7
17.7
MVIL 503
1 1/4"
424
417
156
136
133
118
21.1
21.1
MVIL 504
1 1/4"
448
448
156
156
133
126
24.5
21.5
MVIL 505
1 1/4"
472
156
126
21.8
MVIL 506
1 1/4"
543
193
148
25.2
MVIL 507
1 1/4"
567
193
148
25.6
MVIL 902
1 1/2"
470
470
156
156
133
126
23.5
23.5
MVIL 903
1 1/2"
470
156
126
23.9
MVIL 904
1 1/2"
547
193
148
27.3
Nasslufer-Pumpen
Material
Seals
EPDM
Viton
Threaded connection
Oval flange
Round flange
Systeme
Hydraulic connection
3~230 V, 50 Hz
3~400 V, 50 Hz
3~500 V, 50 Hz
1~110 V, 60 Hz
1~220 V, 60 Hz
3~220 V, 60 Hz
3~380 V, 60 Hz
3~400 V, 60 Hz
3~440 V, 60 Hz
3~460 V, 60 Hz
3~480 V, 60 Hz
IP 54
IP 55
Ex-protected motors
1~230 V, 50 Hz
Pumpenmanagement
Individual motors
Trockenlufer-Pumpen
Motor versions
85
Paint finish
Individual paint finishes
optional
Mechanical seals
Tungsten carbide/carbon
optional
SiC/SiC
optional
WRAS
86
4..
8..
16..
Condensate
Water-glycol mixture
(Up to 40% Vol. glycol / from 10% Vol.glycol performance verification required)
12
18
30
80
84
55
32
Nasslufer-Pumpen
Approved fluids
-15 to +110
-15 to +110
-15 to +110
-15 to +110
40
40
40
40
10
10
10
10
1500 - 3770
1500 - 3770
1500 - 3770
1500 - 3770
230/50
220/60
230/50
220/60
230/50
220/60
230/50
220/60
400/50 Y
380/60 Y
400/50 Y
380/60 Y
400/50 Y
380/60 Y
400/50 Y
380/60 Y
Insulation class
Protection class
IP 54
IP 54
IP 54
IP 54
11/4
11/2
2
11/2
Systeme
Trockenlufer-Pumpen
Motor
Connections
Nominal diameter, suction side [Rp]
Nominal diameter, ultimate pressure side [Rp]
11/
Victaulic-connections
Pumpenmanagement
87
4..
8..
16..
Impellers
1.4301/1.4404
1.4301/1.4404
1.4301/1.4404
1.4301/1.4404
Stage chambers
1.4301/1.4404
1.4301/1.4404
1.4301/1.4404
1.4301/1.4404
Pump housing
1.4301/1.4404
1.4301/1.4404
1.4301/1.4404
1.4301/1.4404
1.4404
1.4404
1.4404
1.4404
Materials
Shaft
Seals
EPDM (EP851)/Viton
Housing cover
1.4301/1.4404
1.4301/1.4404
1.4301/1.4404
1.4301/1.4404
Housing base
Mechanical seal
Pressure jacket
Bearing
Pump base
Pump base (in contact with the flow medium)
Tungsten carbide/carbon
1.4301/1.4404
1.4301/1.4404
1.4301/1.4404
1.4301/1.4404
Tungsten carbide
Tungsten carbide
Tungsten carbide
Tungsten carbide
Aluminium
Aluminium
Aluminium
Aluminium
88
80
Wilo-Economy
MHIE 205-2G
6 (n = 100%)
70
5 (n = 90%)
60
50
H[m]
Nasslufer-Pumpen
4 (n = 80%)
40
3 (n = 70%)
30
2 (n = 60%)
10
1 (n = min.)
2
0,5
1,5
2
5
[l/s]
1
1
7 [m3/h]
Trockenlufer-Pumpen
0
15
12
9
6
3
0
0
1,2
1,0
0,8
0,6
0,4
0,2
0
0
50
40
30
20
10
0
0
7 [m3/h]
6
5
1
1
1
1
2
3
4
Q
3
5
7 [m3/h]
6
7 [m3/h]
Pumpenmanagement
P2[kW]
NPSH [m]
Systeme
20
89
50
Wilo-Economy
MHIE 403-2G
6 (n = 100%)
5 (n = 90%)
40
4 (n = 80%)
H[m]
30
3 (n = 70%)
20
2 (n = 60%)
10
1 (n = min.)
P2[kW]
NPSH [m]
0
70
60
50
40
30
20
10
0
0
1,2
1,0
0,8
0,6
0,4
0,2
0
0
16
14
12
10
8
6
4
2
0
0
0,5
1,5
[m3/h]
10
2,5
[l/s]
3
6
5
4
1
3
10
[m3/h]
6
1
1
6
Q
4
8
3
7
4
8
10
[m3/h]
10
[m3/h]
90
100
90
6 (n = 100%)
80
5 (n = 90%)
Nasslufer-Pumpen
Wilo-Economy
MHIE 406-2G
70
4 (n = 80%)
H[m]
60
50
3 (n = 70%)
40
2 (n = 60%)
Systeme
30
20
1 (n = min.)
1
P2[kW]
NPSH [m]
0
16
12
8
4
0
0
2,5
2,0
1,5
1,0
0,5
0
0
70
60
50
40
30
20
10
0
0
0,5
1,5
[m3/h]
10
2,5
[l/s]
3
6
1
1
2
7
Trockenlufer-Pumpen
10
[m3/h]
6
1
4
6
Q
3
7
10
[m3/h]
10
[m3/h]
Pumpenmanagement
10
91
55
Wilo-Economy
MHIE 803-2G
6 (n = 100%)
50
45
5 (n = 90%)
40
H[m]
35
4 (n = 80%)
30
3 (n = 70%)
25
20
2 (n = 60%)
15
10
1 (n = min.)
P2[kW]
NPSH [m]
0
8
6
4
2
0
0
2,5
2,0
1,5
1,0
0,5
0
0
70
60
50
40
30
20
10
0
0
0,5
1,5
8
2
[l/s]
2,5
6
[m3/h]
1
1
[m3/h]
6
2
6
1
1
1
1
3
7
3
7
4
8
4
8
5
9
[m3/h]
[m3/h]
92
35
Nasslufer-Pumpen
Wilo-Economy
MHIE 1602-2G
6 (n = 100%)
30
5 (n = 90%)
25
4 (n = 80%)
H[m]
20
3 (n = 70%)
15
2 (n = 60%)
Systeme
10
5
70
60
50
40
30
20
10
0
12
16
20
12
24
28
16
20
3/h]
32
[l/s]
24
Trockenlufer-Pumpen
2,5
2,0
1,5
1,0
0,5
0
32 [m3/h]
28
6
5
1
0
12
2
20
16
1
0
2
12
16
20
24
3
24
32 [m3/h]
28
4
28
NPSH [m]
12
10
8
6
4
2
0
P2[kW]
1 (n = min.)
6
32 [m3/h]
Pumpenmanagement
93
Wilo-Economy
MHIE 205
6 (n = 100%)
70
5 (n = 90%)
60
50
4 (n = 80%)
40
H[m]
3 (n = 70%)
30
2 (n = 60%)
20
1 (n = min.)
10
0
0
0,5
[m3/h]
1,5
[l/s]
18
NPSH [m]
15
12
5
9
4
3
6
1
3
0
[m3/h]
0
1,2
6
P2[kW]
1,0
0,8
5
0,6
0,4
3
2
0,2
1
0
[m3/h]
0
60
p[%]
50
40
30
20
10
1
[m3/h]
0
94
50
Nasslufer-Pumpen
Wilo-Economy
MHIE 403 single phase
6 (n = 100%)
45
40
5 (n = 90%)
35
4 (n = 80%)
H[m]
30
25
3 (n = 70%)
Systeme
20
2 (n = 60%)
15
10
1 (n = min.)
Trockenlufer-Pumpen
0
0
0,5
1,5
10
11
2,5
[m3/h]
[l/s]
14
12
NPSH [m]
10
8
2
6
4
2
10
11
[m3/h]
11
[m3/h]
11
[m3/h]
1,2
1,0
P2[kW]
6
0,8
5
0,6
4
0,4
3
0,2
1
0
0
10
70
60
40
30
20
Pumpenmanagement
p[%]
50
10
0
0
10
95
Wiring diagrams, motor data Wilo Economy MHIE 2.., 4.., 8.., 16..
Terminal diagrams
3~380 V
1~220 V
SSM
SBM
PE
10
11
12
+ 24 V
In1
+24V
0 -10 V
GND
In2
20mA MP
GND
aux
SSM
DDS
SBM
+ 24 V
off
ON
L3 L2 L1
SSM
Motor data
Wilo-Economy
96
Mains
frequency
Rated voltage
Power
consumption
P1
[Hz]
[V]
MHIE 205
50 and 60
1~220
MHIE 205-2G
50 and 60
3~380/440
1.5
MHIE 403
50 and 60
1~220
1.77
MHIE 403-2G
50 and 60
3~380/440
1.5
MHIE 406-2G
50 and 60
3~380/440
MHIE 803-2G
50 and 60
3~380/440
MHIE 1602-2G
50 and 60
3~380/440
Nominal
power P2
Nominal current IN
1~220 V
[kW]
1.77
3~380 V
3~440 V
[A]
1.1
11.9
1.1
3.2
2.6
1.1
11.9
1.1
3.2
2.6
2.9
2.2
6.3
5.4
2.6
2.2
5.4
4.6
2.9
2.2
6.3
5.4
Nasslufer-Pumpen
X
L5
L3
L4
1/4"
H1
D1
H
H2
D2
1/4"
7
52
8,5
L1
L2
Systeme
9
108
190
L4
L3
D2
D1
H1
H2
1/4"
Trockenlufer-Pumpen
L5
37
52
1/4"
8,5
L1
108
L2
190
Dimensions, weights
L
L1
L2
L3
L4
L5
D1
D2
H1
[mm]
H2
[mm]
Weight
[kg]
MHIE 205
460.0
252.0
87.5
157.5
51
150
180
Rp 1
Rp 1
284
90
104
180
17.2
MHIE 205-2G
448.0
252.0
103.5
157.5
51
158
198
Rp 1
Rp 1
317
90
104
154
14.6
MHIE 403
412.0
204.0
87.5
109.5
51
150
180
Rp1
Rp 1
284
90
104
180
15.7
MHIE 403-2G
400.0
204.0
103.5
109.5
51
158
198
Rp 1
Rp 1
317
90
104
154
14.6
MHIE 406-2G
511.0
276.0
136.5
181.5
51
182
222
Rp 1
Rp 1
344
100
104
172
21.5
MHIE 803-2G
451.0
216.0
136.5
121.5
51
182
222
Rp 1 Rp 1
344
100
104
172
19.7
MHIE 1602-2G
470.5
235.5
136.5
138.0
54
182
222
344
100
105
172
19.3
Rp2
Rp 1
Pumpenmanagement
Wilo-Economy...
97
Variants overview Wilo-Multivert MVIE 2.., 4.., 8.., 16.., 16-6.., 32.., 52..
Wilo-Multivert MVIE
2.., 4.., 8.., 16..-6
Wilo-Multivert MVIE
16.., 32.., 52..
EPDM
Viton
Threaded connection
Oval flange
Round flange
Individual motors
1~230 V, 50 Hz
3~230 V, 50 Hz
3~400 V, 50 Hz
3~500 V, 50 Hz
1~110 V, 60 Hz
1~220 V, 60 Hz
3~220 V, 60 Hz
3~380 V, 60 Hz
3~400 V, 60 Hz
3~440 V, 60 Hz
3~460 V, 60 Hz
3~480 V, 60 Hz
IP 44
IP 54
IP 55
Ex-protected motors
Material
Seals
Hydraulic connection
Motor versions
98
Wilo-Multivert MVIE
2.., 4.., 8.., 16..-6
Wilo-Multivert MVIE
16.., 32.., 52..
optional
optional
optional
optional
SiC/SiC
optional
optional
KTW
WRAS
Nasslufer-Pumpen
Variants overview Wilo-Multivert MVIE 2.., 4.., 8.., 16.., 16-6.., 32.., 52..
Paint finish
Individual paint finishes
Mechanical seals
Tungsten carbide/carbon
Pumpenmanagement
Trockenlufer-Pumpen
Systeme
99
4..
8..
16..-6
16
32
52
Condensate
Water-glycol mixture
(Up to 40% Vol. glycol / from 10% Vol.
glycol performance verification required)
11
20
34
34
65
98
235
230
190
110
250
185
150
Approved fluids
-15 to +120 -15 to +120 -15 to +120 -15 to +120 -15 to +120 -15 to +120 -15 to +120
40
40
40
40
40
40
40
25
25
25
25
25
25
25
10
10
10
10
10
10
10
1500 - 3770 1500 - 3770 1500 - 3770 1500 - 3770 1500 - 3770 1500 - 3770 1500 - 3770
Motor
Mains connection 1~ [V/Hz]
(Permissible voltage tolerance 10%)
230/50
220/60
230/50
220/60
230/50
220/60
230/50
220/60
230/50
220/60
230/50
220/60
230/50
220/60
400/50 Y
380/60 Y
400/50 Y
380/60 Y
400/50 Y
380/60 Y
400/50 Y
380/60 Y
400/50 Y
380/60 Y
400/50 Y
380/60 Y
400/50 Y
380/60 Y
Insulation class
Protection class
IP 54
IP 54
IP 54
IP 54
IP 54
IP 54
IP 54
25
32
40
50
65
80
80
Connections
Victaulic-connections
= available, = not available
100
4..
8..
16..-6
16
32
52
Impellers
1.4301/
1.4404
1.4301/
1.4404
1.4301/
1.4404
1.4301/
1.4404
1.4301/
1.4404
1.4301/
1.4404
1.4301/
1.4404
Stage chambers
1.4301/
1.4404
1.4301/
1.4404
1.4301/
1.4404
1.4301/
1.4404
1.4301/
1.4404
1.4301/
1.4404
1.4301/
1.4404
Pump housing
1.4301/
1.4404
1.4301/
1.4404
1.4301/
1.4404
1.4301/
1.4404
1.4301/
1.4404
1.4301/
1.4404
1.4301/
1.4404
Shaft
1.4057/
1.4404
1.4057/
1.4404
1.4057/
1.4404
1.4057/
1.4404
1.4057/
1.4404
1.4057/
1.4404
1.4057/
1.4404
Seals
EPDM (EP851)/Viton
Housing cover
1.4301/
1.4404
1.4301/
1.4404
1.4301/
1.4404
1.4301/
1.4404
1.4301/
1.4404
1.4301/
1.4404
1.4301/
1.4404
Housing base
1.4301/
1.4404
1.4301/
1.4404
1.4301/
1.4404
1.4301/
1.4404
Bearing
Pump base
1.4301/
1.4404
1.4301/
1.4404
1.4301/
1.4404
1.4301/
1.4404
1.4301/
1.4404
1.4301/
1.4404
1.4301/
1.4404
Tungsten
carbide
Tungsten
carbide
Tungsten
carbide
Tungsten
carbide
Tungsten
carbide
Tungsten
carbide
Tungsten
carbide
Systeme
Wolfram carbide/graphit
SiC/carbon
EN-GJL-250/1.4408
Trockenlufer-Pumpen
Mechanical seal
Pressure jacket
Nasslufer-Pumpen
Material
Pumpenmanagement
Note on materials:
1.4301 satisfies AISI 304. 1.4404 satisfies AISI 316L.
101
70
65
Wilo-Multivert
MVIE 204
6(n = 100%)
65
55
5(n = 90%)
50
45
H[m]
40
4(n = 80%)
35
3(n = 70%)
30
25
2(n = 60%)
20
15
10
1(n = min.)
5
0
P[%]
P2[kW]
NPSH [m]
0
10
8
6
4
2
0
1,0
0,8
0,6
0,4
0,2
0
50
40
30
20
10
0
0,5
[m 3/h]
1,5
2
5
[l/s]
4
3
[m 3/h]
7
6
5
4
2
1
0
1
0
3
5
2
3
4
Q
3
5
4
6
[m 3/h]
6
7
[m 3/h]
102
70
65
Wilo-Economy
MVIE 204-2G
6 (n = 100%)
60
55
Nasslufer-Pumpen
5 (n = 90%)
50
45
4 (n = 80%)
H[m]
40
35
3 (n = 70%)
30
25
2 (n = 60%)
Systeme
20
15
10
1 (n = min.)
1
0,5
4
1
2
5
2
2
7 [m3/h]
6
1,5
1
0
[l/s]
7 [m3/h]
6
5
1
0
2
3
4
Q
3
5
7 [m3/h]
4
6
50
40
30
20
10
0
6
7 [m3/h]
Pumpenmanagement
NPSH [m]
1,2
1,0
0,8
0,6
0,4
0,2
0
18
15
12
9
6
3
0
P2[kW]
Trockenlufer-Pumpen
103
130
Wilo-Economy
MVIE 208-2G
120
6 (n = 100%)
5 (n = 90%)
110
100
90
4 (n = 80%)
H[m]
80
70
3 (n = 70%)
60
50
2 (n = 60%)
40
30
20
1 (n = min.)
10
P2[kW]
NPSH [m]
0
14
12
10
8
6
4
2
0
0
2,5
2,0
1,5
1,0
0,5
0
0
60
50
40
30
20
10
0
0
0,5
7 [m3/h]
6
1,5
2
5
[l/s]
1
1
7 [m3/h]
6
1
1
2
3
4
Q
3
5
5
7 [m3/h]
4
6
6
7 [m3/h]
104
240
Wilo-Economy
MVIE 214-2G
6 (n = 100%)
220
200
Nasslufer-Pumpen
5 (n = 90%)
180
160
4 (n = 80%)
H[m]
140
120
3 (n = 70%)
100
2 (n = 60%)
80
Systeme
60
40
1 (n = min.)
0,5
1,5
1
1
[l/s]
2
5
7 [m3/h]
7 [m3/h]
6
5
2
1
0
1
0
4
Q
2
3
3
5
7 [m3/h]
4
6
60
50
40
30
20
10
0
6
7 [m3/h]
Pumpenmanagement
NPSH [m]
4,0
3,0
2,0
1,0
0
14
12
10
8
6
4
2
0
P2[kW]
Trockenlufer-Pumpen
20
105
45
Wilo-Multivert
MVIE 403
6(n = 100%)
40
5(n = 90%)
35
30
H[m]
4(n = 80%)
25
3(n = 70%)
20
2(n = 60%)
15
10
1(n = min.)
5
0
NPSH [m]
1,0
0,8
0,6
0,4
0,2
0
P[%]
P2[kW]
0
12
10
8
6
4
2
0
60
50
40
30
20
10
0
0,5
1,5
[m 3/h]
[l/s]
2,5
6
4 5
2
0
[m 3/h]
6
5
4
3
2
1
0
3
8
4
9
[m 3/h]
6
[m 3/h]
106
50
Wilo-Economy
MVIE 403-2G
6 (n = 100%)
40
Nasslufer-Pumpen
5 (n = 90%)
4 (n = 80%)
H[m]
30
3 (n = 70%)
20
Systeme
2 (n = 60%)
10
1 (n = min.)
0,5
6
1,5
6
Q
4
8
3
7
4
8
[l/s]
3
6
10
[m3/h]
6
5
10
5
9
[m3/h]
10
1
1
9
2,5
1
1
Trockenlufer-Pumpen
0
60
50
40
30
20
10
0
0
1,4
1,2
1,0
0,8
0,6
0,4
0,2
0
0
18
15
12
9
6
3
0
0
10
[m3/h]
Schalt- und Regelgerte
6
[m3/h]
Pumpenmanagement
P2[kW]
NPSH [m]
107
100
Wilo-Economy
MVIE 406-2G
6 (n = 100%)
90
80
5 (n = 90%)
70
4 (n = 80%)
H[m]
60
50
3 (n = 70%)
40
2 (n = 60%)
30
20
1 (n = min.)
10
P2[kW]
NPSH [m]
0
20
15
10
5
0
0
2,5
2,0
1,5
1,0
0,5
0
0
60
50
40
30
20
10
0
0
0,5
6
1,5
6
Q
2
7
[l/s]
3
6
10
[m3/h]
6
[m3/h]
10
9
2,5
1
1
10
10
[m3/h]
6
[m3/h]
108
160
Wilo-Economy
MVIE 410-2G
6 (n = 100%)
140
Nasslufer-Pumpen
5 (n = 90%)
120
4 (n = 80%)
H[m]
100
80
3 (n = 70%)
60
2 (n = 60%)
20
1 (n = min.)
0,5
1,5
[m3/h]
10
2,5
[l/s]
3
6
Trockenlufer-Pumpen
0
20
15
10
5
0
0
4,0
3,0
2,0
1,0
0
0
60
50
40
30
20
10
0
0
1
1
10
[m3/h]
6
5
4
2
1
1
1
1
6
Q
3
8
10
10
[m3/h]
6
[m3/h]
Pumpenmanagement
P2[kW]
NPSH [m]
Systeme
40
109
Wilo-Multivert
MVIE 414
6 (n = 100%)
220
200
5 (n = 90%)
180
160
4 (n = 80%)
140
120
H[m]
3 (n = 70%)
100
80
2 (n = 60%)
60
40
1 (n = min.)
20
0
0
0,5
1,0
1,5
[m3/h]
10
2,0
2,5
[l/s]
3,0
15
6
5
4
NPSH [m]
10
3
2
5
0
0
[m3/h]
10
6,0
P2[kW]
4,8
3,6
5
4
2,4
3
1,2
2
1
0
0
[m3/h]
10
60
50
p[%]
40
30
20
2
10
0
0
10
[m3/h]
110
60
Nasslufer-Pumpen
Wilo-Multivert
MVIE 803
6 (n = 100%)
50
5 (n = 90%)
40
30
2 (n = 60%)
10
1 (n = min.)
NPSH [m]
2,4
2,0
1,6
1,2
0,8
0,4
0
p[%]
P2[kW]
0
8
7
6
5
4
3
2
1
0
70
60
50
40
30
20
10
0
10
14
10
16
18
12
14
16
[l/s]
[m3/h]
20
1
0
12
18
[m3/h]
20
6
5
10
12
14
1
0
10
12
Q
4
16
16
18
[m3/h]
20
3
14
18
Trockenlufer-Pumpen
20
Systeme
3 (n = 70%)
20
[m3/h]
Pumpenmanagement
H[m]
4 (n = 80%)
111
50
45
6 (n = 100%)
40
5 (n = 90%)
35
Wilo-Economy
MVIE 803-2G
4 (n = 80%)
H[m]
30
25
3 (n = 70%)
20
2 (n = 60%)
15
10
1 (n = min.)
P2[kW]
NPSH [m]
0
10
8
6
4
2
0
0
2,5
2,0
1,5
1,0
0,5
0
0
70
60
50
40
30
20
10
0
0
10
12
14
16
[l/s]
5
6
[m3/h]
18
1
2
10
12
14
16
18
[m3/h]
6
1
6
10
12
1
2
10
Q
12
14
3
14
4
16
4
16
5
18
5
18
[m3/h]
6
[m3/h]
112
100
90
Nasslufer-Pumpen
Wilo-Economy
MVIE 806-2G
6 (n = 100%)
5 (n = 90%)
80
70
4 (n = 80%)
H[m]
60
50
3 (n = 70%)
40
2 (n = 60%)
30
1 (n = min.)
10
12
14
16
18
[l/s]
5
6
[m3/h]
Trockenlufer-Pumpen
0
10
8
6
4
2
0
0
5
4
3
2
1
0
0
70
60
50
40
30
20
10
0
0
1
2
10
12
14
16
18
[m3/h]
6
1
6
10
1
2
10
Q
12
3
14
12
14
16
16
5
18
5
18
[m3/h]
Schalt- und Regelgerte
NPSH [m]
P2[kW]
6
[m3/h]
Pumpenmanagement
10
0
Systeme
20
113
Wilo-Multivert
MVIE 808
140
6(n = 100%)
120
5(n = 90%)
100
4(n = 80%)
H[m]
80
3(n = 70%)
60
2(n = 60%)
40
1(n = min.)
20
0
0
10
12
14
16
18
[m 3/h]
20
[l/s]
NPSH [m]
15
10
6
50
0
0
10
12
14
16
18
20
[m 3/h]
P2[kW]
4
5
3
3
2
1
1
0
0
10
12
14
16
18
20
[m 3/h]
70
60
P[%]
50
40
30
20
10
0
0
10
12
14
16
18
20
[m 3/h]
114
200
Wilo-Multivert
MVIE 811
6(n = 100%)
180
160
5(n = 90%)
140
120
4(n = 80%)
3(n = 70%)
80
60
Systeme
H[m]
100
2(n = 60%)
40
20
Trockenlufer-Pumpen
1(n = min.)
0
0
10
12
14
16
18
20
[m 3/h]
[l/s]
NPSH [m]
15
10
6
50
0
2
10
12
14
16
18
20
[m 3/h]
0
8
P2[kW]
6
5
4
4
3
2
1
0
0
10
12
14
16
18
20
[m 3/h]
70
60
40
30
Pumpenmanagement
P[%]
50
20
10
0
0
10
12
14
16
18
20
[m 3/h]
115
35
Wilo-Economy
MVIE 1602-2G
6 (n = 100%)
30
5 (n = 90%)
25
4 (n = 80%)
H[m]
20
3 (n = 70%)
15
2 (n = 60%)
10
5
NPSH [m]
2,5
2,0
1,5
1,0
0,5
0
12
10
8
6
4
2
0
P2[kW]
70
60
50
40
30
20
10
0
1 (n = min.)
10
2
15
20
25
30
[m3/h]
[l/s]
8
6
10
15
20
25
30
[m3/h]
6
1
10
15
1
0
10
15
2
20
20
4
25
30
4
25
5
30
[m3/h]
6
[m3/h]
116
55
Wilo-Economy
MVIE 1603-2G
6 (n = 100%)
50
45
Nasslufer-Pumpen
3~400 V
5 (n = 90%)
40
H[m]
35
4 (n = 80%)
30
3 (n = 70%)
25
2 (n = 60%)
20
Systeme
15
10
1 (n = min.)
70
60
50
40
30
20
10
0
10
2
15
20
10
25
30
15
[l/s]
20
25
[m3/h]
30
[m3/h]
6
1
10
15
1
0
10
15
2
20
20
4
25
30
4
25
5
30
[m3/h]
Schalt- und Regelgerte
NPSH [m]
4
3
2
1
0
12
10
8
6
4
2
0
P2[kW]
Trockenlufer-Pumpen
6
[m3/h]
Pumpenmanagement
117
Wilo-Multivert
MVIE 1605
6(n = 100%)
80
70
5(n = 90%)
H[m]
60
4(n = 80%)
50
40
3(n = 70%)
30
2(n = 60%)
20
1(n = min.)
10
[m 3/h]
0
12
18
24
30
[l/s]
15
NPSH [m]
6
10
0
0
12
18
24
[m 3/h]
30
P2[kW]
5
6
4
5
3
4
2
3
2
1
1
0
0
12
18
24
[m 3/h]
30
70
P[%]
50
30
10
0
0
12
18
24
30
[m 3/h]
118
160
Wilo-Multivert
MVIE 1606
6(n = 100%)
140
120
5(n = 90%)
100
4(n = 80%)
H[m]
80
3(n = 70%)
Systeme
60
2(n = 60%)
40
20
0
0
NPSH [m]
0,5
[m 3/h]
1,5
Trockenlufer-Pumpen
1(n = min.)
[l/s]
25
6
20
15
10
5
0
1
[m 3/h]
P2[kW]
12
8
6
5
4
4
1
0
0
[m 3/h]
40
Pumpenmanagement
P[%]
60
20
1
0
0
[m 3/h]
119
120
Wilo-Multivert
MVIE 1607
6(n = 100%)
110
100
90
5(n = 90%)
H[m]
80
4(n = 80%)
70
60
3(n = 70%)
50
40
2(n = 60%)
30
20
1(n = min.)
10
0
0
12
18
24
[m 3/h]
30
[l/s]
15
NPSH [m]
6
10
0
0
12
18
24
[m 3/h]
30
8
6
6
P2[kW]
5
4
4
3
2
2
1
0
0
12
18
24
[m 3/h]
30
60
50
P[%]
40
30
20
10
1
0
0
12
18
24
30
[m 3/h]
120
6(n = 100%)
Nasslufer-Pumpen
200
Wilo-Multivert
MVIE 1608
180
160
5(n = 90%)
140
H[m]
120
4(n = 80%)
100
3(n = 70%)
Systeme
80
2(n = 60%)
60
40
1(n = min.)
0
0
10
15
20
2,5
25
[m 3/h]
30
Trockenlufer-Pumpen
20
[l/s]
7,5
NPSH [m]
25
6
20
15
10
5
10
15
20
25
30
[m 3/h]
P2[kW]
16
12
6
8
5
4
4
1
0
0
10
15
20
25
30
[m 3/h]
40
Pumpenmanagement
P[%]
60
20
1
0
0
10
15
20
25
30
[m 3/h]
121
240
Wilo-Multivert
MVIE 1610
6(n = 100%)
220
200
5(n = 90%)
180
160
4(n = 80%)
H[m]
140
120
3(n = 70%)
100
80
2(n = 60%)
60
40
1(n = min.)
20
0
0
10
15
20
2,5
25
30
[m 3/h]
[l/s]
7,5
25
6
NPSH [m]
20
15
10
5
0
0
10
15
20
25
[m 3/h]
30
20
P2[kW]
16
6
12
5
8
4
4
3
1
0
0
10
15
20
25
[m 3/h]
30
P[%]
60
40
20
1
30
[m 3/h]
0
0
10
15
20
25
122
50
Nasslufer-Pumpen
Wilo-Multivert
MVIE 3202
6(n = 100%)
40
30
4(n = 80%)
20
3(n = 70%)
Systeme
H[m]
5(n = 90%)
2(n = 60%)
10
0
0
10
2
20
4
30
6
40
10
12
50
[m 3/h]
14
[l/s]
Trockenlufer-Pumpen
1(n = min.)
5
0
6
P2[kW]
10
10
20
30
40
4
2
0
[m 3/h]
50
10
20
1
30
40
50
NPSH [m]
15
[m 3/h]
50
30
10
0
1
0
10
20
2
30
Q
40
5 6
50
[m 3/h]
Pumpenmanagement
P[%]
70
123
70
6(n = 100%)
60
50
H[m]
Wilo-Multivert
MVIE 3203
5(n = 90%)
40
4(n = 80%)
30
3(n = 70%)
20
2(n = 60%)
10
1(n = min.)
0
0
0
10
2
20
4
30
6
40
10
50
12
[m 3/h]
14
[l/s]
NPSH [m]
15
5
0
P2[kW]
10
10
20
8
6
4
2
0
30
40
50
[m 3/h]
1
0
10
20
30
40
50
[m 3/h]
4
50
5 6
P[%]
70
50
30
10
0
1
0
10
20
2
30
Q
3
40
[m 3/h]
124
80
Wilo-Multivert
MVIE 3203/11
6(n = 100%)
H[m]
70
60
5(n = 90%)
50
4(n = 80%)
40
Nasslufer-Pumpen
3(n = 70%)
30
Systeme
2(n = 60%)
20
1(n = min.)
10
20
30
40
50
10
1
0
10
20
10
8
6
4
2
0
[m 3/h]
[l/s]
5
10
60
15
20
15
P2[kW]
0
0
30
40
50
60
[m 3/h]
6
4
3
2
1
0
10
20
10
20
NPSH [m]
Trockenlufer-Pumpen
10
30
40
30
2
40
50
60
[m 3/h]
5
60
[m 3/h]
P[%]
80
60
40
20
0
4
50
Pumpenmanagement
125
110
Wilo-Multivert
MVIE 3204
6(n = 100%)
100
90
5(n = 90%)
80
70
H[m]
4(n = 80%)
60
50
3(n = 70%)
40
2(n = 60%)
30
20
1(n = min.)
10
0
10
NPSH [m]
30
40
50
10
[m 3/h]
60
15
[l/s]
6
15
10
5
0
P2[kW]
20
10
20
30
40
50
60
[m 3/h]
12
6
8
4
0
30
2
40
30
2
40
1
0
10
20
10
20
3
50
60
[m 3/h]
P[%]
60
40
20
0
4
50
5
60
[m 3/h]
126
140
Wilo-Multivert
MVIE 3205
6(n = 100%)
120
5(n = 90%)
80
4(n = 80%)
60
3(n = 70%)
H[m]
100
Nasslufer-Pumpen
20
1(n = min.)
10
NPSH [m]
20
30
40
50
10
[m 3/h]
60
Trockenlufer-Pumpen
Systeme
2(n = 60%)
40
[l/s]
15
6
15
10
5
0
10
20
30
40
50
[m 3/h]
60
16
6
8
4
0
1
0
10
20
30
40
P2[kW]
12
50
[m 3/h]
60
P[%]
60
40
20
0
1
0
10
20
30
3
40
4
50
6
60
[m 3/h]
Pumpenmanagement
127
160
Wilo-Multivert
MVIE 3206
6(n = 100%)
H[m]
140
120
5(n = 90%)
100
4(n = 80%)
80
3(n = 70%)
60
2(n = 60%)
40
1(n = min.)
20
0
10
NPSH [m]
30
40
50
[m 3/h]
60
10
15
[l/s]
6
15
10
5
0
P2[kW]
20
20
16
12
8
4
0
10
20
30
40
50
60
[m 3/h]
10
20
10
20
40
30
2
40
1
30
50
60
[m 3/h]
P[%]
60
40
20
0
3
50
6
60
[m 3/h]
128
200
Wilo-Multivert
MVIE 3207
6(n = 100%)
180
Nasslufer-Pumpen
160
5(n = 90%)
140
H[m]
120
4(n = 80%)
100
3(n = 70%)
80
Systeme
2(n = 60%)
60
40
1(n = min.)
20
0
10
5
40
50
10
[m 3/h]
60
[l/s]
15
6
15
10
5
0
P2[kW]
30
24
20
16
12
8
4
0
10
20
30
40
50
[m 3/h]
60
10
20
10
20
1
30
40
NPSH [m]
20
Trockenlufer-Pumpen
50
[m 3/h]
60
P[%]
60
40
20
0
2
30
40
4
50
6
60
[m 3/h]
Pumpenmanagement
129
60
Wilo-Multivert
MVIE 5202
6(n = 100%)
40
5(n = 90%)
30
4(n = 80%)
H[m]
50
3(n = 70%)
20
2(n = 60%)
10
1(n = min.)
0
10
NPSH [m]
20
30
40
50
10
60
70
15
80
20
90 [m 3/h]
25 [l/s]
20
15
6
10
5
0
8
10
20
30
40
50
60
70
80
P2[kW]
2
0
90 [m 3/h]
10
20
30
10
20
30
1
40
50
2
60
70
80
90 [m 3/h]
3
60
4
70
5
80
6
90 [m 3/h]
P[%]
80
60
40
20
0
1
40
50
Q
130
100
90
Nasslufer-Pumpen
Wilo-Multivert
MVIE 5203
6(n = 100%)
80
5(n = 90%)
70
60
4(n = 80%)
40
3(n = 70%)
30
2(n = 60%)
Systeme
H[m]
50
20
1(n = min.)
10
20
30
40
50
10
60
70
15
90 [m 3/h]
80
20
25
Trockenlufer-Pumpen
10
[l/s]
15
5
0
10
20
30
40
50
60
70
12
8
4
0 0
80
P[%]
90 [m 3/h]
80
10
20
30
10
20
30
1
40
50
2
60
70
P2[kW]
10
90 [m 3/h]
80
60
40
20
0 0
1
40
50
Q
3
60
4
70
5
80
6
90 [m 3/h]
Pumpenmanagement
NPSH [m]
20
131
120
Wilo-Multivert
MVIE 5204
6(n = 100%)
110
100
5(n = 90%)
90
H[m]
80
4(n = 80%)
70
60
3(n = 70%)
50
40
2(n = 60%)
30
20
1(n = min.)
10
0
10
20
30
40
50
10
60
70
15
90 [m 3/h]
80
20
25
[l/s]
NPSH [m]
20
15
5
0
P2[kW]
10
20
16
12
8
4
0
10
20
30
10
20
30
10
20
30
40
1
40
50
60
70
50
60
90 [m 3/h]
80
70
90 [m 3/h]
80
P[%]
80
60
40
20
0
1
40
50
Q
3
60
4
70
5
80
6
90 [m 3/h]
132
160
Wilo-Multivert
MVIE 5205
6(n = 100%)
140
Nasslufer-Pumpen
120
5(n = 90%)
H[m]
100
4(n = 80%)
80
3(n = 70%)
60
Systeme
2(n = 60%)
40
1(n = min.)
10
20
30
40
50
10
60
70
15
90 [m 3/h]
80
20
25
Trockenlufer-Pumpen
20
[l/s]
15
5
0
P2[kW]
10
24
20
16
12
8
4
0
10
20
30
40
50
60
70
90 [m 3/h]
80
10
20
30
10
20
30
1
40
50
60
70
NPSH [m]
20
90 [m 3/h]
80
80
40
20
0
1
40
50
Q
3
60
4
70
5
80
6
90 [m 3/h]
Pumpenmanagement
P[%]
60
133
SSM
SBM
L3
L2
L1 PE
off
ON
SSM
aux
SBM
20mA MP
I1 I2
0-10 V
D1 D2 D3
In2
GND
GND
SBM
In1
+24V
L3 L2 L1
SSM
DDS
4-20 mA
+ 24 V
CA CV
Motor data
Wilo-Multivert...
134
Mains
frequency
Rated
voltage
Power
consumption
P1
Rated
power
P2
Nominal current
IN
3~220 V
[kW]
3~380 V
3~440 V
[Hz]
[V]
MVIE 204
50 and 60
1~220
1.77
1.1
13.5
[A]
-
MVIE 204-2G
50 and 60
3~380/440
1.5
1.1
3.2
2.6
MVIE 208-2G
50 and 60
3~380/440
2.8
2.2
6.1
5.2
MVIE 214-2G
50 and 60
3~380/440
4.8
10.3
8.9
MVIE 403
50 and 60
1~220
1.27
1.1
13.5
MVIE 403-2G
50 and 60
3~380/440
1.5
1.1
3.2
2.6
MVIE 406-2G
50 and 60
3~380/440
2.9
2.2
6.2
5.3
MVIE 410-2G
50 and 60
3~380/440
4.8
10.2
8.8
MVIE 414
50 and 60
3~380/440
6.8
5.5
11.6
10.1
MVIE 803
50 and 60
3~380/440
2.85
2.2
5.8
5.0
MVIE 803-2G
50 and 60
3~380/440
2.6
2.2
5.7
4.9
MVIE 806-2G
50 and 60
3~380/440
10.6
9.1
MVIE 808
50 and 60
3~380/440
6.8
5.5
11.6
10.1
MVIE 811
50 and 60
3~380/440
9.3
7.5
15.5
13.7
MVIE 1602-6-2G
50 and 60
3~380/440
2.8
2.2
6.1
5.2
MVIE 1603-6-2G
50 and 60
3~380/440
4.5
9.7
8.3
MVIE 1605-6
50 and 60
3~380/440
6.8
5.5
11.6
10.1
MVIE 1606
50 and 60
3~380/440
11.9
11
19.3
17.5
Power
consumption
P1
Rated
power
P2
Nominal current
IN
3~220 V
3~440 V
[Hz]
[V]
[A]
MVIE 1607-6
50 and 60
3~380/440
9.3
7.5
15.5
13.7
MVIE 1608
50 and 60
3~440
15.5
15
26.1
22.5
MVIE 1610
50 and 60
3~440
19.8
18.5
33.4
28.9
MVIE 3202
50 and 60
3~440
6.8
5.5
11.6
10.1
MVIE 3203
50 and 60
3~440
9.3
7.5
15.5
13.7
MVIE 3203-11
50 and 60
3~440
11.6
11
19.4
16.7
MVIE 3204
50 and 60
3~440
15.3
15
25.8
22.3
MVIE 3205
50 and 60
3~440
18.8
18.5
31.8
29.6
MVIE 3206
50 and 60
3~440
22.2
22
37.5
32.6
MVIE 3207
50 and 60
3~440
25.5
22
42.9
38.0
MVIE 5202
50 and 60
3~440
9.3
7.5
15.5
13.7
MVIE 5203
50 and 60
3~440
15.6
15
26.4
22.7
MVIE 5204
50 and 60
3~440
20.3
18.5
34.1
29.3
MVIE 5205
50 and 60
3~440
24.5
22
41.1
35.5
Pumpenmanagement
Trockenlufer-Pumpen
[kW]
3~380 V
Nasslufer-Pumpen
Mains
frequency
Systeme
Wilo-Multivert...
135
75
Rp11/4/DN32
PN 16
h2
B
85
DN 25
PN 25
20
4 x 14
D
F
E
C
C
D
Victaulic
4 x 12
B
E
F
[mm]
H2
Weight2)
[kg]
MVIE 204
157
212
180
4x12
204 1)
50
100
598.5
330.5
170
205
26.8
MVIE 204-2G
157
212
180
4x12
204 1)
50
100
600
355
155
237
25.3
4x12
204 1)
50
100
727
437
170
254
37.2
Wilo-Multivert
MVIE 208-2G
MVIE 214-2G
136
157
212
180
MVIE 403
157
212
180
4x12
204 1)
50
100
573.5
306.5
170
205
25.9
MVIE 403-2G
157
212
180
4x12
204 1)
50
100
552
307
155
237
25.3
MVIE 406-2G
157
212
180
4x12
204 1)
50
100
679
389
170
254
36.5
MVIE 410-2G
MVIE 414
157
212
180
4x12
204 1)
50
100
266
308
MVIE 803
187
252
215
4x12
250 1)
80
130
639
374
180
208
33.6
MVIE 803-2G
187
252
215
4x12
250 1)
80
130
664
374
170
254
36.7
MVIE 806-2G
187
252
215
4x12
250 1)
80
130
814
474
220
284
52.8
MVIE 808
187
252
215
4x12
250 1)
80
130
927
553
266
308
78.6
80
130
266
308
80
130
659
369
170
254
38.0
MVIE 811
187
252
215
4x12
250 1)
MVIE 1602-6-2G
187
252
215
4x12
250 1)
1)
2)
without packing
F
[mm]
H2
Weight2)
[kg]
MVIE 1603-6-2G
187
252
215
4x12
250 1)
80
130
794
454
220
184
53.2
MVIE 1605-6
187
252
215
4x12
250 1)
80
130
922
548
266
308
84.3
4x14
300 1)
90
130
1032
582.5
258
335
186.5
80
130
997
623
266
308
96.3
130
313
365
MVIE 1606
MVIE 1607-6
MVIE 1608
190
252
215
187
252
215
4x12
250 1)
215
4x14
MVIE 1610
215
4x14
130
313
350
MVIE 3202
239
235
195
4x14
320
105
195
834
460
266
308
113.6
MVIE 3203
239
235
195
4x14
320
105
195
880
506
266
308
126.1
MVIE 3203-11
239
235
195
4x14
320
105
195
985.5
536
258
335
186.5
MVIE 3204
239
235
195
4x14
320
105
195
1043
582
313
365
206.0
MVIE 3205
239
235
195
4x14
320
105
195
1173
674
313
350
256.5
MVIE 3206
239
235
195
4x14
320
105
195
351
365
MVIE 3207
239
235
195
4x14
320
105
195
351
365
MVIE 5202
260
260
220
4x14
320
105
220
865
491
266
365
126.1
MVIE 5203
260
260
220
4x14
320
105
220
1044
583
313
365
210.0
MVIE 5204
260
260
220
4x14
320
105
220
1143
644
313
350
256.5
MVIE 5205
260
260
220
4x14
320
105
220
1292
767
351
365
292.5
1) Dimension
Systeme
Wilo-Multivert
Nasslufer-Pumpen
Pumpenmanagement
Trockenlufer-Pumpen
2) without packing
137
F
[mm]
H2
Weight1)
[kg]
MVIE 204
172
212
180
4x12
250
75
100
622.5
355.5
170
205
28.5
MVIE 204-2G
172
212
180
4x12
250
75
100
601
356
155
237
26.6
MVIE 208-2G
172
212
180
4x12
250
75
100
752
462
170
254
38.6
MVIE 214-2G
172
212
180
4x12
250
75
100
956
616
220
284
57.1
MVIE 403
172
212
180
4x12
250
75
100
598.5
331.5
170
205
28.2
MVIE 403-2G
172
212
180
4x12
250
75
100
577
332
155
237
26.6
MVIE 406-2G
172
212
180
4x12
250
75
100
704
414
170
254
37.9
MVIE 410-2G
172
212
180
4x12
250
75
100
860
520
220
284
54.7
MVIE 414
172
212
180
4x12
250
75
100
1009
635
266
308
82.1
MVIE 803
187
252
215
4x12
280
80
130
639
374
180
208
34.6
MVIE 803-2G
187
252
215
4x12
250
80
130
664
374
170
254
37.1
MVIE 806-2G
187
252
215
4x12
250
80
130
814
474
220
284
53.2
MVIE 808
187
252
215
4x12
280
80
130
1028
654
266
308
78.4
MVIE 811
187
252
215
4x12
280
80
130
1047
673
266
308
89.9
MVIE 1602-6-2G
187
252
215
4x12
250
80
130
659
369
170
254
38.0
MVIE 1603-6-2G
187
252
215
4x12
250
80
130
794
454
220
184
53.2
MVIE 1605-6
187
252
215
4x12
300
90
130
922
548
266
308
84.3
MVIE 1606
190
252
215
4x14
300
90
130
1032
582.5
258
335
186.5
MVIE 1607-6
187
252
215
4x12
300
90
130
997
623
266
308
96.3
MVIE 1608
190
252
215
4x14
300
90
130
1112.5
651.5
313
365
208.5
MVIE 1610
190
252
215
4x14
300
90
130
1219.5
720.5
313
350
254.5
MVIE 3202
260
260
220
4x14
320
120
220
849
475
266
308
117.6
MVIE 3203
260
260
220
4x14
320
120
220
895
521
266
308
128.1
MVIE 3203-11
260
260
220
4x14
320
120
220
1000.5
551
258
335
193.5
MVIE 3204
260
260
220
4x14
320
120
220
1058
597
313
365
213.0
MVIE 3205
260
260
220
4x14
320
120
220
1188
689
313
350
262.0
MVIE 3206
260
260
220
4x14
320
120
220
1214
689
351
365
299.5
MVIE 3207
260
260
220
4x14
320
120
220
1357
832
351
365
320.0
MVIE 5202
220
4x14
220
266
308
MVIE 5203
260
260
220
4x14
320
105
220
1044
583
313
365
210.0
MVIE 5204
260
260
220
4x14
320
105
220
1143
644
313
350
256.5
MVIE 5205
260
260
220
4x14
320
105
220
1292
767
351
365
292.5
Wilo-Multivert
1)
138
without packing
MVIE 204-2G
212
180
210
50
42.4
MVIE 208-2G
212
180
210
50
42.4
MVIE 214-2G
212
180
210
50
42.4
MVIE 403-2G
212
180
210
50
42.4
MVIE 406-2G
212
180
210
50
42.4
MVIE 410-2G
212
180
210
50
42.4
171.5
100
210
50
42.4
MVIE 803-2G
252
215
261
80
42.4
MVIE 806-2G
252
215
261
80
42.4
MVIE 808
187
130
261
80
60.3
MVIE 811
187
130
261
80
60.3
Pumpenmanagement
Trockenlufer-Pumpen
Systeme
MVIE 414
Nasslufer-Pumpen
[mm]
139
Pumpen Intelligenz.
Worldwide the name Wilo is synonymous with the tradition of first class German engineering.
Our pumps and pump systems for heating, air conditioning, cooling, water supply and sewage are
used in all areas of public life: in commercial buildings, communal facilities, industry as well
as in private homes. In close cooperation with our customers, we have over the decades
further developed our know-how from pumps and beyond to system competence.
This know-how is the basis for solutions which are geared towards meeting the special
needs of our customers: that is what we call Pumpen Intelligenz.
WILO AG
Nortkirchenstrae 100
44263 Dortmund
Germany
T +49 231 4102-0
F +49 231 4102-7363
www.wilo.com
Croatia
WILO Hrvatska d.o.o.
10090 Zagreb
T +38 51 3430914
F +38 51 3430930
wilo-hrvatska@wilo.hr
Azerbaijan
WILO Caspian LLC
1014 Baku
T +994 12 4992386
F +994 12 4992879
info@wilo.az
Czech Republic
WILO Praha s.r.o.
25101 Cestlice
T +420 234 098 711
F +420 234 098 710
info@wilo.cz
Belarus
WILO Bel OOO
220035 Minsk
T +375 17 2503393
F +375 17 2503383
wilobel@wilo.by
Denmark
WILO Danmark A/S
2690 Karlslunde
T +45 70 253312
F +45 70 253316
wilo@wilo.dk
Belgium
WILO SA/NV
1083 Ganshoren
T +32 2 4823333
F +32 2 4823330
info@wilo.be
Bulgaria
WILO Bulgaria Ltd.
1125 Sofia
T +359 2 9701970
F +359 2 9701979
info@wilo.bg
Estonia
WILO Eesti O
12618 Tallinn
T +372 6509780
F +372 6509781
info@wilo.ee
Finland
WILO Finland OY
02330 Espoo
T +358 207401540
F +358 207401549
wilo@wilo.fi
Canada
WILO Canada Inc.
Calgary, Alberta T2A5L4
T/F +1 403 2769456
bill.lowe@wilo-na.com
France
WILO S.A.S.
78310 Coignires
T +33 1 30050930
F +33 1 34614959
info@wilo.fr
China
WILO SALMSON (Beijing)
Pumps System Ltd.
101300 Beijing
T +86 10 80493900
F +86 10 80493788
wilobj@wilo.com.cn
Great Britain
WILO (U.K.) Ltd.
DE14 2WJ BurtonUpon-Trent
T +44 1283 523000
F +44 1283 523099
sales@wilo.co.uk
Greece
WILO Hellas AG
14569 Anixi (Attika)
T +302 10 6248300
F +302 10 6248360
wilo.info@wilo.gr
Hungary
WILO Magyarorszg Kft
2045 Trkblint
(Budapest)
T +36 23 889500
F +36 23 889599
wilo@wilo.hu
Ireland
WILO Engineering Ltd.
Limerick
T +353 61 227566
F +353 61 229017
sales@wilo.ie
Italy
WILO Italia s.r.l.
20068 Peschiera
Borromeo (Milano)
T +39 25538351
F +39 255303374
wilo.italia@wilo.it
Kazakhstan
WILO Central Asia
050002 Almaty
T +7 3272 785961
F +7 3272 785960
in.pak@wilo.kz
Korea
WILO Pumps Ltd.
621-807 Gimhae
Gyeongnarn
T +82 55 3405809
F +82 55 3405885
wilo@wilo.co.kr
Latvia
WILO Baltic SIA
1019 Riga
T +371 7 145229
F +371 7 145566
mail@wilo.lv
Portugal
Bombas Wilo-Salmson
Portugal Lda.
4050-040 Porto
T +351 22 2076900
F +351 22 2001469
bombas@wilo-salmson.pt
Lebanon
WILO SALMSON
Lebanon
12022030 El Metn
T +961 4 722280
F +961 4 722285
wsl@cyberia.net.lb
Romania
WILO Romania s.r.l.
041833 Bucharest
T +40 21 4600612
F +40 21 4600743
wilo@wilo.ro
Lithuania
WILO Lietuva UAB
03202 Vilnius
T/F +370 2 236495
mail@wilo.lt
Russia
WILO Rus ooo
123592 Moscow
T +7 495 7810690
F +7 495 7810691
wilo@orc.ru
Montenegro
WILO Beograd d.o.o.
11000 Beograd
T +381 11 2850410
F +381 11 2851278
office@wilo.co.yu
Serbia
WILO Beograd d.o.o.
11000 Beograd
T +381 11 2850410
F +381 11 2851278
office@wilo.co.yu
The Netherlands
WILO Nederland b.v.
1948 RC Beverwijk
T +31 251 220844
F +31 251 225168
info@wilo.nl
Slovakia
WILO Slovakia s.r.o.
82008 Bratislava 28
T +421 2 45520122
F +421 2 45246471
wilo@wilo.sk
Norway
WILO Norge AS
0901 Oslo
T +47 22 804570
F +47 22 804590
wilo@wilo.no
Poland
WILO Polska Sp. z.o.o.
05-090 Raszyn
T +48 22 7026161
F +48 22 7026100
wilo@wilo.pl
Slovenia
WILO Adriatic d.o.o.
1000 Ljubljana
T +386 1 5838130
F +386 1 5838138
wilo.adriatic@wilo.si
Spain
WILO Ibrica S.A.
28806 Alcal de Henares
(Madrid)
T +34 91 8797100
F +34 91 8797101
wilo.iberica@wilo.es
Sweden
WILO Sverige AB
35246 Vxj
T +46 470 727600
F +46 470 727644
wilo@wilo.se
Switzerland
EMB Pumpen AG
4310 Rheinfelden
T +41 61 8368020
F +41 61 8368021
info@emb-pumpen.ch
Turkey
WILO Pompa Sistemleri
San. ve Tic. A.S.
34857 Istanbul
T +90 216 6610203
F +90 216 6610212
wilo@wilo.com.tr
Ukraina
WILO Ukraina t.o.w.
01033 Kiew
T +38 044 2011870
F +38 044 2011877
wilo@wilo.ua
USA
WILO-EMU LLC
Thomasville, Georgia
31758-7810
T +1 229 584 0098
F +1 229 584 0234
terry.rouse@wilo-emu.com
USA
WILO USA LLC
Calgary, Alberta T2A5L4
T/F +1 403 2769456
bill.lowe@wilo-na.com
Georgia
0177 Tbilisi
T/F +995 32317813
info@wilo.ge
Macedonia
1000 Skopje
T/ F +389 2122058
valerij.vojneski@wilo.com.mk
Moldova
2012 Chisinau
T/ F +373 2 223501
sergiu.zagurean@wilo.md
Tajikistan
Dushanbe
T +992 93 5554541
Uzbekistan
100046 Taschkent
T/F +998 71 1206774
info@wilo.uz
August 2006
Subject to technical modifications. In appliance of our General Terms of Delivery and Service (see www.wilo.com)
W2690/2500/0609/GB/MP
B3