Vous êtes sur la page 1sur 5

quietrevolution

Electrical System Overviews and Schematics

qr5 - Vertical Axis Wind Turbine

Revision History Version A Notes V1.4 updated Original Document Author(s) KPR AM & AW 25/06/2010 11/11/08 Checked TY AM 30/06/2010 11/11/08 Approved TY RC 01/07/10 11/11/08

Filename: C.005 - quietrevolution Electrical System Overview and Schematic

quietrevolution ltd. 1.11 Clerkenwell Workshops, 31 Clerkenwell close, London EC1R 0AT Tel: +44 20 7014 3399 Fax: +44 20 7014 3388 Email: info@quietrevolution.com

www.quietrevolution.com
Registered in England No. 5405104 VAT No. 918 5666 85

quietrevolution
Supplied by quietrevolution

q r5 E LE CT RICAL SYST E M : O V E RV IE W
Control Panel
Control Interface Board MCU ISU Relay / Switches Terminals Line-side Filters

Grid Metering Board


Junction Box Isolator Switch Bi-Directional Energy Meter

Control Computer

quietrevolution ltd. 1.11 Clerkenwell Workshops, 31 Clerkenwell close, London EC1R 0AT Tel: +44 20 7014 3399 Fax: +44 20 7014 3388 Email: info@quietrevolution.com

www.quietrevolution.com
Registered in England No. 5405104 VAT No. 918 5666 85

quietrevolution
brown black grey
To NEXUS To NEXUS To NEXUS To NEXUS & WFU-01 Filters Fan To NEXUS & WFU-01 Filters Fan

C ON TROL PAN EL
blue

EM-Brake
L N E L

24Vdc PSU
N E +24Vdc 0Vdc

K1 Q2
16A 3-Phase MCB

12

11

13

15

14

16

K3 Q3

+A1

G83 Protection Relay

10A MCB

Contactor

8
1mmsq brown

6
1mmsq black

4
1mmsq grey

2
1mmsq blue

-A2
To NEXUS

Q1
1
Isolator Swicth

Panel earth

K2

-A2

Contactor

+A1
To NEXUS

L1

L2

L3

UDC+

UDC-

UDC+

L1

L2

L3

U2

V2

W2

U2

V2

W2

UDC-

Incoming Supply from Metering Board WFU-01 Filter


quietrevolution ltd
1.11, Clerkenwell Workshops 31 Clerkenwell Close London, EC1R 0AT Tel: +44 20 7014 3399 Fax: +44 20 7014 3388 Web: http://www.quietrevolution.com Email: info@quietrevolution.com Notes: Revisions:
No. A Date. 04/05/10 Comment. First issue

To NEXUS

g/y

ACSM1 - ISU
Scale Date

ACSM1 - MCU

N/A 04-05-10 MAS TY/RA

Project

Job No.

N/A
Drawing Title
QR5 v1.4 Turbine Control Backboard 5C-K006-A 2010-05-04 A

N/A
Drawing No.
2010-05-04 A

Drawn by

Checked by

quietrevolution
GRI D METE RING B OARD
brown black grey
To Control Computer & Modem* To Control Computer & Modem*

Mains Socket
L N E L

12Vdc PSU
N E +12Vdc 0Vdc

blue g/y Panel earth

Q1
1
Isolator Swicth

P1
3 5 N

10

Q2
16A MCB

Bi-Directional Energy Meter

12

Incoming supply rating No. of turbines Minimum rating (A)


1 16 2 25 3 32 4 40 5 50 6 63 7 63 8 63 For installations of greater than 8 turbines, contact quietrevolution to discuss connection requirements.

L1

L2

L3

L1

L2

L3

Incoming Grid Supply Connection

To Turbine Control Backboard

quietrevolution ltd

1.11, Clerkenwell Workshops 31 Clerkenwell Close London, EC1R 0AT Tel: +44 20 7014 3399 Fax: +44 20 7014 3388 Web: http://www.quietrevolution.com Email: info@quietrevolution.com

Notes: * GPRS modem is optional

Revisions:
No. A Date. 04/05/10 Comment. First issue

Scale Date

N/A 04-05-10 MAS TY/RA

Project

Job No.

N/A
Drawing Title
QR5 v1.4 Metering Backboard 5C-K009-A 2010-05-04 A

N/A
Drawing No.
2010-05-04 A

Drawn by

Checked by

quietrevolution
Supplied by quietrevolution

qr5 ELECTRICAL SYSTEM: M ULT I- T URBINE O V E RV IE W

Control Panel
Control Interface Board MCU ISU Relay / Switches Terminals Line-side Filters

Control Panel
Control Interface Board MCU ISU Relay / Switches Terminals Line-side Filters

Grid Metering Board


Junction Box Isolator Switch Bi-Directional Energy Meter

Control Computer

quietrevolution ltd. 1.11 Clerkenwell Workshops, 31 Clerkenwell close, London EC1R 0AT Tel: +44 20 7014 3399 Fax: +44 20 7014 3388 Email: info@quietrevolution.com

www.quietrevolution.com
Registered in England No. 5405104 VAT No. 918 5666 85

Vous aimerez peut-être aussi