AIREDALE RS Creating a Healthier & Safer Environment for our Children Sentinel’ UNIT VENTILATOR UV-H HOT WATER HEATING UV-S STEAM HEATING UV-C CHILLED WATER COOLING UV-CH 2-PIPE COOLING/HEATING UV-CHW 4-PIPE COOLING & HEATING ENGINEERING MANUAL COMFORT RANGE TABLE OF CONTENTS General Description . General Specifications & Options. Component Layout. Unit Operation . Dimensional Details UVH & UVS Heating Capacity Data C Cooling Capacity Data. UV.CH Cooling & Heating Capacity Data. Uv. UV-CHW Cooling & Heating Capacity Data... 14-15 Technical Specification Tables... 0.250.565 16 Fan Motor Matrix « 17 Electrical Data Tables... 118 “Typical Supply Air Arrangements +19 Plenums . . 20 Standard Wall Sleeve and Louver Arrangements... 21 Rear Extensions... 00.0.0 cece eee eee 2223 GENERAL DESCRIPTION UNIT IDENTIFICATION AIREDALE OVERVIEW INTRODUCTION Ey wv Unit Ventilator with Economizer UVEW, ..... Standard Unit Ventilator with Energy Recovery Wheel UvEB Unit Ventilator with Coil Face and Bypass Section and Econom 3, 4, § & 6. Nominal Cooling, Capacity: 3 ~ 30 Mbh 4— 40 Mh 5 = 50 Mbh. 6-60 Mbh Hot Water Heating Only — Slab Coil Steam Heating Only — Slab Coil Chilled Water Cooling Only — “A” Frame Coil Pipe Cooling/Heating — “A” Frame Coil 4 Pipe Cooling & Heating — “A” Frame Coil Coil Rows: H select 1 or 2 rows heating S.1 row heating fixed C select 3 or 4 rows cooling CH select 3 oF 4 rows cooling (3 or 4 rows heating CHW select 3 oF 4 rows cooling (I row heating fixed) Model UVSCHW is a standard unit ventilator, nominal cooing capacity SOMbh, with 4 rows cooling and 1 row heating, and economizer Aitedale, located in Bensalem, PA, is one of the wor’ lading manufacturers of heating and air conditioning systems for schools. .\ reputation for product excellence has been earned through innovative design and the highest quality controls in the selection of component parts and the manufacture and assembly of unit ‘eatilators. Exensive use of CADICAM and other computerized systems refets Airedale’ commitment to he latest design and manufacturing technology to maintain leadership inthe production of systems of unsurpassed quality and reliability. In addition to creating a healthier and safer learning environment for our children, many of the features in Atedale products are unique and the range of systems available offer schools a variety of options. The Sentinel unit ventilator isthe perfect solution for schools that have to improve the indoor air quality of their classrooms. It operates in conjunction with a school’s central chlleboiler plant and is available in five models: Chilled Water, Hot Water, Steam or a combination of both Chilled and Hot Water, (two-pipe and four- pie configurations) Airedale specifically designed and engineered the Sentinel to provide the proper amount of fresh air ventilation, and to enable schools to minimize their eneegy consumption > Sentinel” SPECIFICATIONS GENERAL ‘SPECIFICATIONS ‘CABINET cous SUPPLY FAN & FAN MOTOR FILTER ECONOMIZER (UV and UVEB only) ‘The unit shall bea chilled water coolinghot water heating or combined chilled water cooling and hot water heating unit ventilator. Steam heating shall also be available. The unit shall be floor- mounted and vertically configured to allow supply air to be ducted or supplied through a high level plenum. All access and maintenance shall be through the front ofthe unit. ‘The unit shall be constructed in accordance with ETL and CSA standards, and a label shall be affixed to the unit listing the product code under which itis registered. ‘The unit shall bea product of the ISO 9001: 2000 Quality Standard and be fully assembled and tested prior to shipment “The cabinet shall be constructed from galvanized sheet steel. After assembly the cabinet shall e degreased and coated with dey powder, epoxy resin paint, baked afer application. Standard color shall be hammertone beige (CODE: Cardinal TO13-BG38).. The pain finish shall be easily clanable and hard wearing to give maximum protection. The cabinet shall be insulated with acoustic foam insulation containing no fibrous materials. The foam insulation shall have aie rating of UL94HF-1 ‘The front of the unit shall contain a low-level tamperproof return ai grille integral to the front of the door and a sound attenuating inlet plenum. The door shall be hinged with a spring-loaded pin to allow for easy removal if required. Doors shall he secured with a two key locks “The back of the cabinet shall have an opening for connection to a wall sleeve and louver. Knockouts for field piping connections shall be located at the top and lower sides of the unit. All factory installed pipework shall be fully insulated with 3/8” wall closed cell type insulation ‘Twin large surface area coils shall be arranged in an ‘A’ frame configuration to optimize heat transfer and airflow, “Hot water ot steam heating only units shall utilize horizontal slab coils. Separate coil assemblies shall be utilized for all dhe units within the range. Standard and high capacity chilled water coil assemblies, standard and high capacity hot water coil assemblies, four pipe chilled water & hot water coil assemblies, and also standard steam heating cols shall be used dependant on unie configuration, ach coil shall be manufactured from refrigeration quality 38” diameter copper tubing mechanically bonded onto aluminum fins with col circuitry designed to ensure minimum waterside pressure drops. Each coil shall be fited with an air bleed atthe high point ofthe coil and a drain plug at che low point. All cols subject to chilled water flow shall be mounted in an ABS vacuum formed condensate tray. Al coil assemblies shall be factory installed and piped to the standaed unit connections. Supply airflow shall be provided by a double inlet, forward curved, centrifugal fan with integral direct drive motor. ‘The assembly shall be statically and dynamically balanced to ensure smooth running and minimum noise levels. The fan motor shall he a permanent split capacitor type complete with integral automatic thermal overload protection ‘The fan assembly shall be positioned for a *blow through” configuration, to maximize the mixing of outside air and room aie before the aie passes over the coil) Each unit shall be fitted with a 1” thick pleated disposable synthetic filter designed to meet ASHRAE standard 52-76. The filter shall be accessible from the front of the unit for easy replacement, however it shall be ‘mounted in a position so that all return and outdoor air shall be ftered prior to Being conditioned ‘The fier shall be teated with a durable, low toxicity, broad spectrum antimicrobial that inhibits the growth of bacteria and fangi on the fier surfaces, Each unit shall be fitted with a spring return modulating damper that ats to mix the outdoor aie with the return ait. The damper shall have the capability of permitting only the outside ar into the space, or recycling the retum air and allowing only a minimum of outside air to enter the space. Full modulation allowing any mixture of outside air and return air shall be possible. A minimum damper position setting shall also be posible 0 conus mann oui ar vention eureens dependent on contol via he units microprocessor controle. ‘The damper blade shall pivot on sel-lubricaring nylon bearings and modulate using an electronically controlled

Vous aimerez peut-être aussi