Vous êtes sur la page 1sur 45

Calculator 03.25.03 Ver. 2.

Calculator Is For Reference Only! Always Check Calculations Manually!


All Input Welcome, Improvement, Repairs, Additional Calculations
The Most Recent Version Can Be Downloaded At The CPS Portal file:\\halweb.halnet.com\km\cps\Calculators and Converters Contact keith.white@halliburton.com

Area
Annular Area Single String Annular Area Multiple Strings Area Of A Circle Area Between Two Circles Cross-Sectional Area ( Seal Assy. Inserted )

Circle
Circumference Of A Circle Diameter Of A Circle Radius Of A Circle

Constants
Thermal Coefficients Fresh Water Facts

Conversions
Barrel To Cu./ Ft. Cubic Foot To Barrel Cubic Foot To Cubic Inches
Gradient

Specific Gravity To Gradient API Gravity To Gradient Density lb./ ft.3 To Gradient
Measurement

Decimal To Fraction Fraction To Decimal Inche To Foot Converion


Specific Gravity

Fluid Weight lb./ gal. To Specific Gravity API Gravity To Specific Gravity Density lb./ ft.3 To Specific Gravity

Directional Well Calculations


To Find TVD From MD To Find MD From TVD To Find Deviation Factor To Find True Vertical Length Of Slant To Find Slant Factor Directional Acronyms

Fluid
Fluid Weight To Gradient Fluid Velocity Fluid Weigh Up Fluid Cut Back KCL CaCl2 Weigh Up ( Using 94-97% CaCl2 ) CaBr2 & ZnBr2 Weigh Up ( Using 94-97% CaCl2 ) CaBr2 & ZnBr2 Weigh Up ( Using 95% CaBr2 )

Gravel Pack
Yield & Fluid Wt. Of Slurry After Adding Sand Wash Pipe / Screen Ratio ( Optimum Is 80% ) Minimum Clearance For Gravel Pack Completions Drift Plate Tolerance

Leaks
Locating

Packer
Velocity Of Fluid Across Packer Elements

Piston Effects
Piston Force Exerted Piston Pressure Created

Pressure
Hydrostatic Pressure Fluid Weight Required For BHP @ Depth Maximum Allowable Pump Pressure

Pumps
Triplex Pump Output Barrels Per Stroke

SCSSV
Maximum Leakage Rate of SCSSV and Plugs Maximum Fail-Closed Setting Depth Specific Gravity To Gradient Recommended Control Line Hold Open Pressure Control Line Fluid Volume

Shear Pins
To Calculate Pin Shear Force Pressure Required To Shear Pins

Slickline
Area Of A Slickline Tool String Balance Weight Neglecting Friction Stem Weight Stem Length Needed Neglecting Friction Minimum Bending Diameter Of Wire Wire Weight Wire Weight Balance Depth Wire Strength ( approximate / standard plow steel ) Spool Capacity Tubing Fill-Up Rule Of Thumb Hydrostatic Rule Of Thumb Rule Of Thumb For WireLine Fall-Back Area Of Pipe

Temperature
Average Pipe Temperature Change In pipe length ( inches ) due to temperature change Change In Average Tubing Temperature, Injecting / Acidizing Condition Change In Average Tubing Temperature, Flowing Condition Converting Temperature Change To Length Change

Tubing
I.D. Calculated Joint Yield Strength Of EUE Tubing Cross-Sectional Area Of Pipe Tubing Weight In Air Tubing Weight With Upsets & Coupling Tubing Weight In Fluid Buoyancy Factor Buoyancy Factor Bull Plugged In Fluid ( lb./ ft. ) Tubing Capacity Tubing Fill-Up Factors

Tubing Fill-Up Tubing Displacement Pipe Stretch Slack-Off Data Slack-Off Factor Determining Pipe Pull Free Pipe Depth

Volume
Rectangular Volume / Capacity Cylindrical Volume / Capacity Spherical Volume / Capacity Pipe / Hose Volume

Enter Necessary Information In Highlighted A FOR REFERENCE ONLY


Annular Area Single String
( ID2 x .7854 ) - ( OD2 x .7854 ) = Annular Area

Casing ID Tubing OD

8.291 2.875

Area In2 47.497

Annular Area Multiple Strings


( ID2 x .7854 ) - (( OD2 +OD2 + OD2 + OD2 ) x .7854 ) = Annular Area

Casing ID Tubing OD #1 Tubing OD #2 Tubing OD #3 Tubing OD #4

8.291 2.375 2.375

Area In2 45.129

ormation In Highlighted Areas EFERENCE ONLY

Enter Necessary Information In Highlighted A FOR REFERENCE ONLY


Area Of A Circle
3.1416 x Radius2 = Area

Radius Diameter

6.000 3.000

Area Area

113.098 7.069

Diameter2 x .7854 = Area

Area Between Two Circles


( ID2 x .7854 ) - ( OD2 x .7854 ) = Area Between Circles

Outer Circle ID Inner Circle OD

5.000 4.000

Area 7.069

Cross-Sectional Area ( Seal Assy. Inserted )


((ID2 - ID2 ) x .7854 = Area

Receptacle ID Seal Assy. ID

3.000 2.330

Area 2.805

ormation In Highlighted Areas EFERENCE ONLY

Enter Necessary Information In Highlighted Ar FOR REFERENCE ONLY


Fresh Water Facts Density = 62.4 lb./ cu.ft. Weight = 8.33 lb./ gal. Fluid Gradient = 0.433 Specific Gravity = 1.000 API Gravity = 10.000 Fluid Gradient Of 1 lb./ gal. Fluid = 0.051948 Pi = 3.1416 1 Barrel = 42 gallon 1 Barrel = 5.6146 cu./ ft. 1 Barrel = 9702 sq./ in.. 1 Cubic Foot = 1728 cu./ in. 1 Cubic Foot = 0.1781 barrels 1 Cubic Foot = 7.4805 gallon 1 Cubic Foot = .1781 barrel 1 Gallon = .00238 barrel 1 Gallon = .1337 cu./ ft. 1 Gallon = 231 cu./ in. Thermal Coefficients Steel = 0.0000069 13Cr. = 0.0000057 Inc. 825 & 925 = 0.0000078 Hastalloy C-276 = 0.0000067 Coefficiet of thermal expansion ( or Contraction ) for steel per unit of length per Degree F = .0000069 Barrel To Cu./ Ft.
Barrels x 5.6146 = Cu./ Ft.

SPECIFIC GRAVITY
Fluid Weight lb./ gal. To Specific Gravity Fluid Wt. / 8.33 = S.G.

Fluid Wt.lb./ gal.

10

S.G.

API Gravity To Specific Gravity 141.5 / ( 131.5 + API Gravity ) = S.G.

API Gravity

40
3

S.G.

Density lb./ ft. To Specific Gravity Desity lb./ ft.3 / 62.4 = Specific Gravity

Desity lb./ ft.3

70 GRADIENT

S.G.

Specific Gravity To Gradient S.G. x .433 = Gradient

Specific Gravity

1.2

Gradient

API Gravity To Gradient 61.28 / ( 131.5 + API Gravity ) = Gradient

API Gravity

40
3

Gradient

Density lb./ ft. To Gradient Desity lb./ ft.3 / 144 = Gradient

Desity lb./ ft.

70 CIRCLE

Gradient

Circumference Of A Circle Pi 3.1416 x Diameter = Circumference

Diameter 2

Circumference 6.2832
Diameter Of A Circle Circumference / Pi 3.1416 = Diameter

Circumference

6.2832

Diameter

Radius Of A Circle Diameter / 2 = Radius

Barrels

Cubic Ft.

11.229

Diameter

Radius

Cubic Foot To Barrel


Cubic Ft x .1781 = Barrel

Cubic Foot

Barrel

0.1781

Cubic Foot To Cubic Inches


Cubic Ft x 1728 = Cubic Inches

Cubic Foot

Cubic In.

1728.000

ation In Highlighted Areas RENCE ONLY


Decimal To Fraction
Decimal Number * Desired Fraction Increment / 8.33 = S.G.

C GRAVITY

al. To Specific Gravity

1.200
API Gravity ) = S.G.

Decimal Number 0.188

o Specific Gravity

0.825 Fraction To Decimal 1.122

To Specific Gravity 2.4 = Specific Gravity

Fraction 12.03 /64 6.02 /32 3.01 /16 1.50 /8 0.75 /4 `

Numerator ( top number ) / Denomanator ( bottom number )

ADIENT

vity To Gradient

33 = Gradient

0.520

Fraction 28 /64 28 /32 13 /16 7 /8

Decimal 0.438 0.875 0.813 0.875

y To Gradient

PI Gravity ) = Gradient

0.357
3

ft. To Gradient / 144 = Gradient

0.486

RCLE Feet 6

nce Of A Circle

eter = Circumference

Circumference 6.2832

r Of A Circle Pi 3.1416 = Diameter

Inche To Foot Converion Inches 75.00 Engineers Tape Feet 6.250 Carpenters Tape Inches Fraction 3 0.00 /64 0.00 /32 0.00 /16 0.00 /8 0.00 /4

2.000
/ 2 = Radius

Of A Circle

1.000

Enter Necessary Information In Highlighted A FOR REFERENCE ONLY


Directional Well Calculations
To Find TVD From MD (( MD - Kickoff Depth) x Deviation Factor)+Kickoff Depth = TVD

MD Kickoff Depth Deviation Factor

10000 5000 0.5


To Find MD From TVD

TVD 7500.00

(( TVD - Kickoff Depth )/ Deviation Factor ) + Kickoff Depth = MD

TVD Kickoff Depth Deviation Factor

7500 5000 0.5


To Find Deviation Factor

MD 10000.00

( TVD - Kickoff Depth ) / ( MD - Kickoff Depth )

TVD MD Kickoff Depth Slant Factor Length Of Pipe

7500 10000 5000 1.5 7500


To Find Slant Factor

Deviation Factor 0.500

To Find True Vertical Length Of Slant

Length 11250

True Height Of Slant / Length Of Slant = Slant Factor True Height Of Slant Length Of Slant

7500

5000

Slant Factor 1.5000

Measurements OF Directional Holes VSS - Vertical depth measured from sea level VSF - Vertical depth from T.H.F. MSF - Drilled depth from T.H.F. MKB - Measure Depth from Kelly Bushing VKB - Vertical depth from Kelly Bushing

ormation In Highlighted Areas EFERENCE ONLY

Enter Necessary Information In Highlighted A FOR REFERENCE ONLY


Fluid Weight To Gradient
Fluid Wt. x .05195 = Gradient

Fluid Weigh Up Gradient 0.5196 Gradient 0.0104


( Desired Wt. - Original Wt. ) / ( Weigh Up Wt. - Desired Wt. ) x Volume To Weigh Up

Fluid Wt.lb./ gal. 10.000


Fluid Wt.lb./ ft.3 / 144 = Gradient

Fluid Wt.lb./ ft.3 1.500

Fluid Velocity Proposed Pumping Rate ( BPM ) 10.00 Outer ID / In. 8.921 Inner OD / In. 2.875 Fluid Velocity ( FPS ) 2.406 Fluid Velocity ( FPM ) 144.340

Volume To Weigh Up ( bbl ) Original Mud Weight ( lb / gal ) Desired Mud Weight ( lb / gal ) Weigh Up Mud Weight ( lb / gal ) Volume Of Weigh Up Mud Needed Total Volume After Weigh Up Fluid Cut Back
( Original Wt. - Desired Wt. ) / ( Desired Wt. - Cut Back Wt. ) x Volume To Cut Back

Volume To Cut Back ( bbl ) Original Mud Weight ( lb / gal ) Desired Mud Weight ( lb / gal ) Cut Back Mud Weight ( lb / gal ) Volume Of Cut Back Mud Needed Total Volume After Weigh Up

ormation In Highlighted Areas EFERENCE ONLY


KCL
3.5 x Fluid Volume x Percent Desired / Sack Size

Fluid Weigh Up

l Wt. ) / ( Weigh Up Wt. - Desired Wt. ) x olume To Weigh Up

300.00 12.00 12.10 14.20 h Up Mud Needed After Weigh Up Fluid Cut Back

14.29 314.29

Percent Desired Fluid Weight ( lb / gal ) Sack Size ( lb ) Fluid Volume ( bbl ) Sacks Required Final Weight

5.00 8.30 50.00 60.00 21.00 8.52

CaCl2 Weigh Up ( Using 94-97% CaCl2 )


( Desired Wt. - Original Wt. ) x ( 7 ) x ( Volume ) / 80 x 10

d Wt. ) / ( Desired Wt. - Cut Back Wt. ) x olume To Cut Back

12.00 11.60 10.30 8.33 Back Mud Needed After Weigh Up

Original Fluid Wt. ( lb / gal ) Desired Weight ( lb / gal ) Fluid Volume ( bbl ) Sacks Required Final Fluid Volume

9.90 10.50 100.00 52.50 105.00

7.92 19.92

CaBr2 & ZnBr2 Weigh Up ( Using 94-97% CaCl2 )


( Desired Wt. - Original Wt. ) x ( 13 ) x ( Volume ) / 80 x 10

Original Fluid Wt. ( lb / gal ) Desired Weight ( lb / gal ) Fluid Volume ( bbl ) Sacks Required Final Fluid Volume

12.10 12.30 500.00 162.50 515.48

CaBr2 & ZnBr2 Weigh Up ( Using 95% CaBr2 )


( Desired Wt.-Original Wt. ) x ( 11.5 ) x ( Volume ) / 55 x ( 10 )

Original Fluid Wt. ( lb / gal ) Desired Weight ( lb / gal ) Fluid Volume ( bbl ) Sacks Required Final Fluid Volume

14.00 14.20 250.00 104.55 255.23

Enter Necessary Information In Highlighted A FOR REFERENCE ONLY


1 Cubic Foot Sand = 100# 1 Pound Sand = .0456 Gallon Sand Slurry Convertion
Yield Of Slurry After Adding Sand 1 + ( .0456 x Concentration Of Sand Pound Per Gallon Slurry )

Concentration Of Sand - Pound Per Gallon Slurry

Carrier Fluid Weight Lb./ Gal. Yield Of Slurry Per Gallon Carrier Fluid
Fluid Weight Of Slurry Lb./ Gal.

(Carrier Fluid Weight Lb. Gal. + Concentration Of Sand Pound Per Gallon Slurry ) / Yield Of Slurry Per Gallon Carrier Fluid

Fluid Weight Of Slurry Lb./ Gal. Wash Pipe / Screen Ratio ( Optimum Is 80% )
Wash Pipe OD / Screen ID = Ratio

Wash Pipe OD

2.875 Ratio

Screen ID x 80% = Optimum Wash Pipe OD

Optimum Wash Pipe OD Minimum Clearance For Gravel Pack Completions Proposed Pumping Rate ( BPM ) Casing ID Completion OD Sand Size Gravel Pack Sand Grain Size

Note: Fluid Velocity Must Be Less Than 60 FPS To Avoid Tool Erosion

Fluid Velocity ( FPS )

Minimum Clearance Represents The Minimum Needed To Safely Pump The Job.

Minimum Allowable Clearance Minimum Allowable Radial Clearance


Current Completion Clearance

Clearance Radial Clearance

ormation In Highlighted Areas EFERENCE ONLY


Drift Plate Tolerance Assembly Minimum ID 1.875 Order Drift Plate 1.870 To 1.860

d Slurry Convertion

Slurry After Adding Sand

ation Of Sand Pound Per Gallon Slurry )

- Pound Per Gallon Slurry

Weight Lb./ Gal. Gallon Carrier Fluid

15 10 1.684

Weight Of Slurry Lb./ Gal.

al. + Concentration Of Sand Pound Per Gallon Of Slurry Per Gallon Carrier Fluid

f Slurry Lb./ Gal.

14.85

reen Ratio ( Optimum Is 80% ) Screen ID 82% 2.800 3.5

pe OD / Screen ID = Ratio

80% = Optimum Wash Pipe OD

ce For Gravel Pack Completions 10.00 8.921 8.750 1.00 0.094

Be Less Than 60 FPS To Avoid Tool Erosion.

56.778

sents The Minimum Needed To Safely Pump The Job.

1.316 adial Clearance 0.171

0.085

t Completion Clearance

0.085

Enter Necessary Information In Highlighted A FOR REFERENCE ONLY


To Locate Leak ( Different Wt. Fluids Tbg. / Csg. ) Psi Differential
Fluid Wt. # 1(Heaviest) Fluid Wt. # 2(Lightest)

500 10 9.3

Leak Depth 13,749

ormation In Highlighted Areas EFERENCE ONLY

Enter Necessary Information In Highlighted A FOR REFERENCE ONLY


Velocity Of Fluid Across Packer Elements Casing ID In. 8.681 Packer OD Length Of Packer Element Pumping / Circulation Rate Fluid Weight In. In. Bpm Ppg 8.47 12 2 9.3

1 Barrel = 1 Gallon =

Conversion Data 5.61458 Cu. / Ft. 0.133681 Cu. / Ft. Bbl. / Ft. 0.0732 Fps 9.48

Casing Capacity Fluid Velocity Going By Elements Equivalent Pipe Speed Pressure Dropped Created Force On Packer Elements Trying To Push Them Out

Min. / Std. 3.60 Psi Lbs. 56 37,788

ormation In Highlighted Areas EFERENCE ONLY

Enter Necessary Information In Highlighted A FOR REFERENCE ONLY


Piston Force Exerted
Piston Area x Pressure = Force

Piston Area 3.1416 Piston O.D. 2

Pressure 10 Pressure 10 Piston Pressure Created

Force 31.416 Force 31.42

(OD2 Piston x .7854) x Pressure =Force

Force / (OD2 Piston x .7854) =Pressure

Force 31.42

Piston O.D. 2

Pressure 10.00

ormation In Highlighted Areas EFERENCE ONLY

Enter Necessary Information In Highlighted A FOR REFERENCE ONLY


Hydrostatic Pressure
Fluid Gradient x TVD = Hydrostatic Psi

Fluid Gradient 0.433 Fluid Wt.lb./ gal. 8.550 Fluid Wt.lb./ ft.3 100.000

TVD 10,000 TVD 10725 TVD 5000

Hyd. Psi 4330.00 Hyd. Psi 4763.75 Hyd. Psi 3472.00

Fluid Wt. x .05195 x TVD = Hydrostatic Psi

Fluid Wt.lb./ ft.3 x 0.00694 x TVD = Hydrostatic Psi

Fluid Weight Required For BHP @ Depth


BHP / ( .05195 x TVD )

BHP TVD

5000 10000

Fluid Wt. lb./ gal. 9.62

Maximum Allowable Pump Pressure Fluid Wt.lb./ gal. Depth Pipe OD Pipe ID Pipe Air Wt.lb./ ft. Tbg. Wt. In Fluid Max. Pump Psi Tbg. Wt.lb./ ft. Air Buoyancy Factor Tbg. Length Pipe OD Max. Pump Psi 8.555 11718 2.875 2.441 6.5 66730.20 10279.12 6.5 0.8727 5000 2.875 4369.00 Hyd. Psi Buoyant 5207.86 Force Area 9436.80 1.812 Tbg Wt. Air O.D. Area 76167 6.492

Tbg. Wt. In Fluid 28362.75 Tbg. OD Area 6.492

ormation In Highlighted Areas EFERENCE ONLY

Enter Necessary Information In Highlighted A FOR REFERENCE ONLY


Triplex Pump Output Barrels Per Stroke
( ID x ID X Stoke Length x .000243 ) x Pump Efficiency / 100

Piston OD ( in ) Stroke Length ( in ) Pump Effeciency ( % ) Barrel Per Stroke Output

3.375 8.00 80.00 0.0177

ormation In Highlighted Areas EFERENCE ONLY

Enter Necessary Information In Highlighted A FOR REFERENCE ONLY


Maximum Leakage Rate of SCSSV and Plugs
MMS Maximum Allowable Leakage Rate is 5 SCF per minute gas and 200 cc per minute liquid GAS (( 4x Psi Increase) x ((( Tubing ID2 ) x 0.005454 ) xDepth )) / Test Length

Recommended Control Line Hold Open Pressure


SHUT IN Valve Opening Psi + SITP + 750 Psi

Opening Pressure Off Certification Sheet Shut In Tubing Pressure


Recommended Hold Open Pressure Note: SCSSV Hold Open Pressure Should Be Adjusted After Well Is Flowing And Stable FLOWING Valve Opening Psi + Flowing Tubing Psi + 750 Psi

Tubing ID Depth Pressure Increase Length Of Test In Minute SCF Per Hour SCF Per Minute
Liquid

2.441 500 50 15 216.65 3.61 CC Per Min. Leakage 66.67 98.58 15

Liquid Recovered CC 1,000.00 Once 50 Length Of Test In Minutes

Opening Pressure Off Certification Sheet Flowing Tubing Pressure Recommended Open Pressure Control Line Fluid Volume OD 0.250 Wall Thickness 0.049 Length Ft. 500 ID 0.152 Total Volume Gallons Quarts 1.885 Pints 3.771 EnerPac P-391 Hand Pump Strokes Required To Displace Control Line

Maximum Fail-Closed Setting Depth


Valve Closing Psi / ( Fluid Gradient x Safety Factor )

Closing Pressure Off Certification Sheet 875 Fluid Gradient 0.35 Safety Factor 1.25 Maximum Fail-Closed Depth 2000 Specific Gravity To Gradient
S.G. x .433 = Gradient

Specific Gravity

0.87

Gradient

0.377

EnerPac P-391 Hand Pump Oil Volume Per Stroke Cu./ In. Strokes Per Gallon Strokes Per Quart Strokes Per Pint Strokes Per Cup Strokes Per Ounce

ormation In Highlighted Areas EFERENCE ONLY


SHUT IN

ontrol Line Hold Open Pressure

ening Psi + SITP + 750 Psi

Off Certification Sheet bing Pressure 6850

1100 5000

Pressure Should Be Adjusted After Well Is lowing And Stable FLOWING

Psi + Flowing Tubing Psi + 750 Psi

Off Certification Sheet bing Pressure 3350

100 2500

ol Line Fluid Volume Area - Sq./ In. 0.018 Gallon Per Foot 0.001 0.471 Cups 7.541 Ounces 60.329 721

Pump Strokes Required Control Line

ac P-391 Hand Pump 0.151 1530 382 191 96 12

Enter Necessary Information In Highlighted A FOR REFERENCE ONLY


To Calculate Pin Shear Force
( OD2 x .7854 ) x Ultimate Shear Strength Ultimate Shear Strength

0.25 Shear Force 50,000 4,909 Number Of Pins 2 To Calculate Pin Ultimate Shear Strength
Shear Force / ( OD2 x .7854 )

Pin OD

Pin OD
Shear Force

0.25 5,000

UltimateShear Strength

101,859

Pressure Required To Shear Pins


Cross-Sectional Area ( Seal Assy. Inserted ) ((ID2 - ID2 ) x .7854 = Area

Receptacle ID Seal Assy. ID Pin Shear Value Quantity Of Pins

3.880 0.000 6,100 12

Piston Area 11.824 Pressure To Shear 6,191 4,334 3,095

Steel Pin Test Pressure =Pressure To Shear x 70%

Steel Pin Test Pressure Brass Pin Test Pressure

Brass Pin Test Pressure =Pressure To Shear x 50%

ormation In Highlighted Areas EFERENCE ONLY

Enter Necessary Information In Highlighted Areas FOR REFERENCE ONLY


Area Of A Slickline
OD2 x .7854 = Area

Wire Weight
( OD2 x 8 ) / 3 = Lbs./ Ft.

Wire Size

0.092

Area

0.0066

Wire Size Length

0.092 13800

Lb./ Ft.

0.02257

(( OD2 x 8 ) / 3) x Length = Total Weight.

Tool String Balance Weight Neglecting Friction


( OD2 x .7854 ) x Pressure = Tool Sting Weight ( balanced )

Total Weight 311.48

Wire Size Pressure

0.092 1500 Stem Weight

Tool String Weight 9.97 Wire Weight Balance Depth


.2945 x Pressure = Depth

( OD2 x 8 ) / 3 = Lbs./ Ft.

Pressure 6.00 4.17

1500

OD OD

1.5 1.25

Lb./ Ft. Lb./ Ft.

Depth 441.75

OD x OD x 2.667 = Lbs./ Ft.

Wire Strength ( approximate / standard plow steel )


( OD2 x .7854 ) x 280000 = Approximate Maximum Breaking Strength

Stem Length Needed Neglecting Friction


Stem Weight Needed / Stem Weight lb./ ft.

Wire Size 0.092 Approximate Max. Strength Wire Size 0.092 Approximate Min. Strength Spool Capacity

1861

Weight Needed Stem Weight lb./ ft.

10 6

Length Needed Ft. 1.667

(( OD2 x .7854 ) x 280000)*.85 = Approximate Minimum Breaking Strength

1582

Minimum Bending Diameter Of Wire


NOTE: Larger sheaves, wheels or pulleys could extend cable / wire life. Stranded, Braided or Conductor Cables Diameter of Cable X 64 = Minimum Bending Diameter In Inches Reference Only ( Assumes Wire Is Perfectly Spooled (Drum Width x ( Flange OD - Drum OD ) / 2 ) x ( Drum OD + ( Flange OD Drum OD ) / 2 ) / (( 4 x ( Wire OD )))

Cable Diameter 1 /2 3 /4 6 /8 3 /16 6 /32 12 /64

Minimum Diameter In. 32 48 48 12 12 12

Enter All Information In Inches Drum Width Between Flanges 31 Flange OD 29 Drum OD 14 Wire OD ( Decimal ) 0.25 Spool Capacity Ft. 19,995

Slickline Wire ( Piano, Solid ) Diameter of Wire X 120 = Minimum Bending Diameter In Inches

Wire Size 0.092

Minimum Diameter In. 11.04

ed Areas
Tubing Fill-Up Rule Of Thumb
ID2 = Barrels Per 1000'

Tbg. ID

2.441

Bbl./ 1000'

6.0

Hydrostatic Rule Of Thumb


.052 x Lb./ Gal. x Depth

Depth Fluid Wt. Lb./ Gal.

13800 8.6

Hydrostatic Pressure 6171.36

Rule Of Thumb For WireLine Fall-Back Top Of Rope Socket Left In Hole 13,800 Length Of Wire Left In Hole Ft. 13,400 7 Wire & Tubing Size Wire Fall Back Ft. Per 1,000' Wire Fall Back Total Footage Top Of Wire ( Approximate ) Area Of Pipe
ID2 x .7854 = Area

12 160.8 561

Pipe ID

2.441

Area

4.680

Enter Necessary Information In Highlighted A FOR REFERENCE ONLY


Temperature
Average Pipe Temperature ( Surface Temp. + BHT ) / 2

Suface Temp. BHT

50 100

Average Temp. 75

Change In pipe length ( inches ) due to temperature change ( Pipe length feet x .0000828 ) x Change in pipe temp.

Pipe length

Change in pipe temp.

10000 Change in length (inches) 50 41.40 Change In Average Tubing Temperature


Flowing Condition

((shutin well head temp + static BHT) / 2) - ((flowing WHT+BHT) / 2) Shutin well head temp

Static BHT
Flowing well head temp

BHT

100 200 150 250

Change -50

Injecting / Acidizing Condition ((SI WHT + SI BHT) / 2) - ((Surf. Fluid temp. + BHT during inj.) / 2)

Shutin BHT Surface fluid temp.

100 250 Change 75 62.5 BHT during treatment 150 Converting Temperature Change To Length Change
Shutin well head temp (Change in Tubing Temperature x Length) x .0000069

Temp. Change Tbg. Length

100 10000

Length Change Inches 6.90

ormation In Highlighted Areas EFERENCE ONLY

Enter Necessary Information In Highlighted Areas FOR REFERENCE ONLY


To Determine Joint Yield Strength Of EUE Tubing
((OD2 tbg - ID2 tbg) x .7854) x Grade = Yield

Tubing Capacity
Tubing Length x Capacity Factor = Capacity Bbl.

Pipe OD Pipe ID Grade

2.375 2.441 110

Yield 105.692

Tbg. Length 5000 Tbg. ID

Cap. Factor 0.00579


.0009714 x ID2 = Bbl./ Ft.

Capacity bbl. 28.95 Bbl./ Ft. Ft./ Bbl. Ft.3/ Ft. Ft./ Ft.3 0.00579 172.762 0.03250 30.771 4.1135

2.441 2.441 2.441 2.441


2

Cross-Sectional Area Of Pipe


((OD2 tbg - ID2 tbg) x .7854 = Area

1029.4 / ID2 = Ft./ Bbl.

Tbg. ID Area 1.304 Tbg. ID Tbg. ID Tbg. ID

Pipe OD Pipe ID

2.375 1.995 Tubing Weight


In Air ( lb./ ft. )

.005454 x ID2 = Ft.3/ Ft. 183.35 / ID2 = Ft./ Ft.2

24.51 / ID = Ft./ Gal.

Tubing Length x Tubing Wt./ Ft. = Total Air Weight

Tbg. Length 1000

Pipe Wt./ Ft. 4.7


( OD2 - ID2 ) x 2.67 x Length feet

Total Wt. 4,700.00

2.441 Ft./ Gal. Tubing Fill-Up Factors

( 3.141592654 x ID2 ) / 77 = Fill-Up Factor Gal./ Ft.

In Air ( Does not allow for upsets or couplings )

Tubing I.D. 2.441 Tubing I.D. 2.441

Fill-Up Factor Gal./ Ft. 0.24310 Fill-Up Factor Ft.3/ Ft. 0.03250 Tubing Fill-Up Barrel 10 Tubing Displacement Fill-Up Ft. 1,727.65

Pipe OD Pipe ID Length

2.375 1.995 1
In Fluid ( lb./ ft. )

Pipe Weight 4.43

( 3.141592654 x ID2 ) / 576 = Fill-Up Factor Ft.3./ Ft.

Tbg. Air Wt. lb./ ft. x (1- (.01528 x Fluid Wt. lb./ ft.))

Fill-Up Factor x Barrels = Fill-Up Footage

Tbg. Wt.lb./ ft. Air 6.5 Buoyancy Factor 0.8471

Fluid Wt.lb./ gal.

10 Tbg. Air Wt. 4.7 Buoyancy Factor

Tbg. Wt. In Fluid 5.5068 Tbg. Wt. In Fluid 3.98137

Fill-Up Factor 172.765

Buoyancy Factor x Tubing Air Weight = Fluid Weight Tubing weight lb./ ft. x .0003638 = Displacement bbl./ ft.

Tubing Wt. lb./ ft. 6.5 Displacement bbl./ ft. 0.8727

0.00236

( 65.42 - Fluid Wt.) / 65.42

Fluid Wt.lb./ gal. Tbg. Wt.lb./ ft. Air Buoyancy Factor Tbg. Length Fluid Wt.lb./ gal. Length Pipe OD Pipe ID Pipe Air Wt.lb./ ft. Tbg. Wt. In Fluid

8.33 6.5 0.8471 1000 10 500 2.875 2.441 6.5 2779.32

Factor

Tubing Air Wt. x Buoyancy Factor x Length = Tbg. Fluid Wt.

Tbg. Wt. In Fluid 5506.15

Hyd. Psi 259.75 Area 1.812

Buoyant Force 470.68 Tbg Wt. Air 3250

Bull Plugged In Fluid ( lb./ ft. )

Fluid Wt.lb./ gal. Depth Pipe OD Pipe Air Wt.lb./ ft.

10 500 2.441 6.5

Hyd. Psi 259.75 Area 4.680

Buoyant Force 1215.58 Tbg Wt. Air

Tbg. Wt. In Fluid

2034.42

3250

ed Areas
Pipe Stretch
Pull x Depth x 12 / ((( OD2 - ID2 ) x 0.7854 ) x 30000000 ) = Inches

Pull 10000 Stretch In Inches

Depth 5000 11.04

Pipe OD 2.875

Pipe ID 2.441

Slack-Off Data
( Desired Wt. Dwn. / 1000 ) x ( Packer Depth / 1000 ) x Factor

Desired Wt. Down 10000

Packer Depth 10000

Factors For Standard Weight Pipe 1.900" 0.68 2 3/8" 4.7 # 0.39 2 7/8" 6.5# 0.26 3 1/2" 9.3# 0.17 Factors For Standard Weight Drill Pipe 2 7/8" 10.4# 0.16 3 1/2" 13.3# 0.12 4 1/2" 16.6# 0.11 To Calculate Slack-Off Factor Pipe OD 2.875 Pipe ID 2.441

Factor 0.26 Slack-Off In. Required 26

Slack-Off Factor 0.26

Determining Pipe Pull


(( 1000 x 1000) x Stretch Inches) / ( Stretch Factor x Length )

Inches Of Stretch Pipe Length Stretch Factor

12 10000 1.544 Free Pipe Depth

Pipe Pull 777

( Stretch Inches x 1000 x 1000) / ( Pull x Factor )

Inches Of Stretch Pull Stretch Factor

24 10000 0.31

Depth Of Free Pipe 7742

Enter Necessary Information In Highlighted A FOR REFERENCE ONLY


Rectangular Volume / Capacity
( In Feet ) Length x Width x Height = Volume Ft3

Spherical Volume / Capacity


Diameter3 x .5236 = Volume

Length Ft. Width Ft. Height Ft.


3

20 10 5
3

Diameter Ft. Volume Ft. 1,000.00 178.10 7,480.20


3

20
Volume Ft3 x .1781 Bbl./ Ft.3 = BBl.

Volume Ft x .1781 Bbl./ Ft. = BBl.

Volume Barrels
Total Barrels x 42 = Gallons

Volume Barrels
Total Barrels x 42 = Gallons

Volume Gallons Pipe / Hose Volume


ID x ID / 1029.4

Volume Gallons
Barrels Total / ( Height feet x 12 )

Barrel Per Inche


Barrels Total / Height feet

2.968333333 35.62

Barrel Per Foot

Cylindrical Volume / Capacity


( Diameter2 x.7854 ) x Height = Volume

Pipe Or Hose ID Pipe Or Hose Length Barrel Per Foot Pipe Or Hose Total Volume

Diameter Ft. Height Ft. Volume Barrels

16 20

Volume Ft.3 4021.248 716.18 30,079.74 2.984 35.809

Volume Ft3 x .1781 Bbl./ Ft.3 = BBl. Total Barrels x 42 = Gallons

Volume Gallons Barrel Per Inche


Barrels Total / Height feet

Barrels Total / ( Height feet x 12 )

Barrel Per Foot

ormation In Highlighted Areas EFERENCE ONLY


Volume Ft.3 4188.8 746.03
Barrels x 42 = Gallons

cal Volume / Capacity

eter3 x .5236 = Volume

Ft3 x .1781 Bbl./ Ft.3 = BBl.

31,333.06

pe / Hose Volume
ID x ID / 1029.4

2.323 15300 0.0052 80.21

Per Foot e Total Volume

Enter Necessary Information In Highlighted A FOR REFERENCE ONLY


Stem Weight
( OD2 x 8 ) / 3 = Lbs./ Ft.

Tubing Weight With Upsets & Coupling


( OD2 - ID2 ) x .7854 x 0.29665 x 12

OD OD

2.125 2.125 Calculated I.D.

Lb./ Ft. Lb./ Ft.

12.04 12.04

OD x OD x 2.667 = Lbs./ Ft.

Pipe OD Pipe ID

2.875 2.441

Pipe OD Weight I.D. Drift

2.875 6.5 2.415 2.290

ormation In Highlighted Areas EFERENCE ONLY


Area Between Two Circles
( ID2 x .7854 ) - ( OD2 x .7854 ) = Area Between Circles

ht With Upsets & Coupling Pipe Weight Lb. / Ft. 6.450

D2 ) x .7854 x 0.29665 x 12

Outer Circle ID Inner Circle OD

5.000 4.000

Area 7.069

Vous aimerez peut-être aussi