Correpcion de ERROR U4 XEROX 5020

1. Check the copy quality. Make several copies using the Test Pattern (499T247), then check the quality. 2. Look at the last 20 error codes in order to understand the machine status. Enter Diagnostic Mode. Enter [40-01] (Display Error History How to Enter the Diagnostic Mode). When the last error code is displayed, press the [Start] key to return to the Function input screen. Pressing the [Stop] key during the display will stop it and return you to the Function input screen. --------------------------------------------------------------------------------------------------Fuser On Time Fail U4-1 Fuser On Time Fail Explanation The lamp did not turn OFF within the specified time after turning ON. Or, Warm Up was not completed within the specified time after power ON. U4-2 Over Heat Temp Fail Explanation A temperature above 250C is continuously detected for 480ms. U4-3 Error FS1 thermistor defect Explanation FS1 cannot be monitored any more U4-4 Fuser Fan defect Explanation After the start of Fan Fail Signal monitoring, the signal level was Low not more than 30 times. -----------------------------------------------------------------------------------------------------------------------------When U4-1 occurs, [NVM 50-20 FSR Reset FuserOverTemp] becomes "3." Run [NVM 50-20 FSR Reset FuserOverTemp] using "0" to reset it. (How to Enter the Diagnostic Mode) Check to see if there is paper in the Fuser. The Fuser is normal and there is no paper in it. -----------------------------------------------------------------------------------How to Enter the Diagnostic Mode There are 2 ways to enter the diagnostic mode depending on the model of the IOT. The procedure below entitled WC 5016, 5020 (with platen or ADF) Entering the Diagnostic Mode is for IOT models with a platen, or with an ADF. The procedure following entitled WC 5020 is for IOT models with a DADF. WC 5016, 5020 (with Platen or ADF) Entering the Diagnostic Mode Press and hold down the [0] button on the keypad for 4 seconds or longer, and then press (and quickly release) the [Start] button while still keeping the [0] button pressed.

Once in the Diagnostic Mode, "C_ " (Chain Code input screen) is shown on the display. The "_" is blinking. ---How to Exit the Diagnostic Mode Switch the machine OFF and then ON again. ---How to Input the Chain and Link (WC 5020 w/DADF) The following shows the Chain and Link input method in the Diagnostic Mode. A Chain/Link Code can be up to 3 digits. If the Chain/Function Code is "1," it must be input as "1." Do necessary to 0 fill. Any input value that goes beyond the 3rd digits will be ignored. To clear the Chain/Link Code that was input, press the "AC" button. Both digits will be cleared, and you will be returned to the Chain Code input screen. When inputting the Link Code, pressing the [Start] button after inputting a Link Code that is out of the specified range will transfer you to the initial screen of Link input. Enter the Diagnostic Mode and check that the "C_ " (Chain Code input screen) is shown on the display.

Vous aimerez peut-être aussi