Vous êtes sur la page 1sur 92

MAYTAS NAFTOGASBUD JV GSPL203-73-1514

Rev 0

CONTENTS PAGE NO
1.0 INTRODUCTION........................................................................................................................................................... 3
1.1 GENERAL ................................................................................................................................................................... 3
1.2 DESIGN PHILOSOPHY ................................................................................................................................................. 3
1.3 REFERENCES ......................................................................................................................................................... 3
2.0 INPUT LOAD CALCULATION......................................................................................................................................... 4
2.1 DEAD LOAD ............................................................................................................................................................... 5
2.2 LIVE LOAD (LL) ........................................................................................................................................................ 8
2.3 WIND LOAD (WL) ..................................................................................................................................................... 9
2.4 SEISMIC LOAD ......................................................................................................................................................... 15
3.0 VIEWS ................................................................................................................................................................................. 17
3.1 ISOMETRIC VIEW ....................................................................................................................................................... 17
3.2 NODE NUMBERS ........................................................................................................................................................ 17
3.3 MEMBER NUMBERS ................................................................................................................................................... 18
3.4 COLUMN NUMBERS ................................................................................................................................................... 18
3.5 STAAD INPUT ............................................................................................................................................................ 19
3.6 SUPPORT REACTION SUMMARY ................................................................................................................................ 28
3.7 COLUMN DESIGN SUMMARY ..................................................................................................................................... 31
4.0 DESIGN CALCULATION ................................................................................................................................................ 31
4.10 SLAB DESIGN........................................................................................................................................................ 31
4.20 DESIGN OF BEAM................................................................................................................................................. 31
4.2.1 PLINTH BEAM.................................................................................................................................... 31
4.2.2. ROOF BEAM ...................................................................................................................................... 31
4.3.0 FOUNDATION DESIGN ....................................................................................................................................... 31
5.0 CONCLUSION ................................................................................................................................................................... 31

ANNEXURE-1
1.0 DESIGN OF SLAB AND BEAM FOR WATER TANK................................................................................................. 31

2.0 DESIGN OF LOCAL LINTEL.................................................................................................................................... 31


2.1 OPENING ≤ 750MM .......................................................................................................................................................... 31
2.2 OPENING ≤ 1000MM ........................................................................................................................................................ 31
2.3 OPENING ≤ 1500MM ........................................................................................................................................................ 31

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 2 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

1.0 INTRODUCTION

1.1 General

The objective of this document is to define the minimum requirements for the design and
engineering of the BHARUCH JAMNAGAR PIPELINE PROJECT.

The general scope of work is for engineering procurement and construction of the Rajkot-
Jamnagar– GSPL pipeline system and related facilities including Despatch Station, SV Stations,
Tap-off station and receiving station.

This pipeline broadly consists of approximately 103.50 Kms of 30” line pipe from existing station
(Receiving Station) at Rajkot on GSPL 24” Anand Rajkot Pipeline to village Pipli at chainage
89.67 Km (Receiving Station at Jamnagar) and subsequently to Reliance Receiving station (at
Reliance premises)

1.2 Design Philosophy

The control Building is a simple RCC structure comprising of Columns, Beams, and Slab at
different levels, This structure has been designed using Staad-Pro computer software. The
Foundations has been designed isolated foundation at a depth of 2.085 m below NGL. The
structure has been designed for future expansion of one floor with approach staircase on side of
building. The columns have been designed using Staad Pro. Beam design has been performed by
taking moments and shear forces from Staad Pro and applied on spread sheets and slab is also
designed using Spread Sheets

1.3 REFERENCES

The following Indian codes and standards shall be generally used for design of Civil and Structural
works. In all cases, latest revisions with amendments if any shall be followed. Apart from the specific
codes mentioned herein, all other relevant and related codes concerning the specific job under
consideration and/or referred to in these codes and technical specifications shall be followed wherever
applicable. (All codes shall be latest as on the date of issuing of tender / bid document.)
i. IS : 875 - (parts I to V) Code of practice for Design loads (other than earthquake) for
Buildings & Structures.
ii. IS : 1893 - Criteria for Earthquake resistant design of structure.

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 3 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

iii 3/07-07-Geotechnical/Sub Soil investigation report

FOUNDATION
iii. IS: 1080- Code of practice for design and construction of shallow
foundations in soils (other than raft, ring and shell).

iv. IS:1904-Code of practice for design and construction of foundations in soils –


General requirements.

v. IS:6403 -Code of practice for determination of bearing capacity of shallow foundations.

vi. IS:8009 (Part-I)- Code of practice for settlement of foundations.

vii. IS: 2911(Part-1/Sec2)-1980-code of Practice For Design and Construction of pile


Foundations

viii. IS: 2911(Part-1/Sec3)-1979-code of Practice For Design and Construction of pile


Foundations

ix. IS: 2911(Part-1/Sec4)-1984-code of Practice For Design and Construction of pile


Foundations

x. IS: 2911(Part-4)-1985-code of Practice For Design and Construction of pile Foundations

xi. IS: 2911(Part-III)-1980-code of Practice For Design and Construction of pile Foundations

CONCRETE STRUCTURES

xii. IS:432–1982(Part1,2) – Specification for mild steel and medium Tensile steel bars and
hard drawn steel wire for concrete reinforcement

xiii. IS:456-2000 – Code of practice of plain and reinforce concrete.

xiv. IS:1786–High strength deformed steel bars and wires for concrete
reinforcement
xv. IS :4326 – Earthquake resistance design and construction of buildings

xvi. IS:1566 – Hard drawn steel wire fabric for concrete reinforcement

xvii. IS:13920 – Code of practice for ductile detailing of RCC structures


subjected to seismic forces

2.0 Input Load Calculation

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 4 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

The loads applied on the structure are Dead Loads, Live Loads, and Wind Loads & Seismic
loads in both the directions
2.1 Dead Load
GROUND LEVEL & FIRST FLOOR SLAB LEVEL

Wall Load
Inner Brick Wall = 0.23x3.5x20
= 16.1 KN/m
Outer Brick Wall (below lintel = 0.23x2.5x20
102.5-100) = 11.5 KN/m
Brick Wall above Lintel (below lintel = 0.23x0.7x20
104-0.5-102.8)) = 3.22 KN/m
Parapet wall = 0.1x0.85x25
= 2.125 KN/m = Say 2.2 KN/m
Weight of Wall below landing Beam = 0.23x1.05x20 (1.05m ht)
(Staircase for Future Expansion) = 4.83 KN/m
Weight of wall above Landing Beam = 0.23x1.95x20 (1.95 ht at bottom of floor Beam)
(Future Landing Beam Depth 500mm) = 8.97 KN/m
Weight of wall at sides of Stair = 0.23x3.5x20
(Stair for Future Expansion) = 16.1 KN/m
Weight of wall at sides of future = 0.115x2.5x20
head room (2.5m ht above beam) = 5.75 KN/m

At First Floor Level (At Level EL (+) 104 M (TOC)):

Slab Wt = 0.15 x 25
= 3.75 KN/m2
Note
1.0 No floor finish load is consider (except cantilever portion) since it has been designed for
LL of 7.5 kN/m2
2.0 Floor Finish load/Water proof of 2 KN/ m2 is applied for cantilever portion
PCC 0.05x24 = 1.2 KN/ m2
Bitumen first course = 0.004 KN/ m2
Bitumen @ 0.012 KN/ m2 = 0.036 KN/ m2
(2nd, 4rd, 6th layers)(0.012x3)

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 5 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

APP Membrane @ 0.012 KN/ m2 = 0.30 KN/ m2


(3rd & 5th layers) (0.15x2Nos)
7th course- 12mm thick plaster = 0.288 KN/ m2
(0.012x24)
Brick Tiles- 3mm thick (0.03x20) = 0.10 KN/ m2
Total = 1.928 KN/ m2 say 2 KN/ m2
Floor Finish Load of 2 KN/ m2 is considered for cantilever portion

At Future Roof Level (At Level EL (+) 108 M (TOC)):

Slab Wt = 0.15 x 25
= 3.75 KN/m2
Water Proofing = 2 KN/m2

Cantilever slab at first floor (At Level EL (+) 104 M (TOC) & (+) 108 M (TOC)
DL 5.75 KN/m

2.2 KN

0.7m
Shear to fixed end of beam = 5.75x0.7+2.2
= 6.225 KN (applied vertical Load on the Beam)
Moment at end of Beam = (5.75x0.72/2)+2.2x0.7
= 2.94 KN-m (moment applied on Cantilever
Slab Supported Beam)
Water Tank
Capacity of Tank = 1000 lit
Weight of water = 1m3 x 10 KN/m3
= 10 KN
Weight of tank = 1 KN
(10% of weight of water)
Weight of Cover Slab = 2.135 x1.5x 0.15 x 25
= 12.00 KN
Self weight of beam = ((2.135x0.2x0.2x25)x2)+((1.5x0.2x0.2x25)x2)
= 7.27 KN

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 6 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

Weight of Pedestal = 0.2 x 0.2 x 0.3 x 25 x 4 (for 4 pedestal)


= 1.2 KN

Load transverse for each Pedestal = (10+1+12.00+7.27+1.2)/4

= 7.86 KN (applied as point load on pedestal supporting beam)


Say 8 KN
Stair Case
250mm
150

175mm Ø

Tan Ø = 175/250
Ø = 35˚
Cos Ø = 150 / X
X = 184 mm
Average slab Thickness = (184 + 150)+175

2
= 255 mm
B
3.873

2.450

1.05 3.0 1.05

1.05 3.873 1.05

DL 0.15x25 0.255x25 0.15x25

Total DL 3.75 6.375 3.75

LL 4 4 4

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 7 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

LL = 4 KN/m2 –IS 875 Part 2


Dead Load Reactions

RA = ((3.75 X 1.05 (1.05/2+4.923)+ 6.375X 3.873 (3.873/2+1.05) +3.75X (1.052/2))/5.973

RA = 16.28 KN

RA + RB = ((3.75 X 1.05)2) + (6.375X3.873)

RB = 16.28 KN

Live Load Reactions

RA = RB = WL/2

= 4 X 5.973/2

= 11.95KN

The above typical load has been applied on beam at Ground floor and First Floor (Future Expansion Floor)

2.2 Live Load (LL)

Live load is consider as per Design Basis

Live Load Cantilever slab at first floor (At Level EL (+) 104 M (TOC)

DL 1.5 KN/m

0.7m

Live Load considered for Cantilever slab is1.5KN/m2

Shear to fixed end of beam = 1.5x0.7

= 1.05 KN (applied vertical Load on the Beam)

Moment at end of Beam = 1.5x0.7x0.7/2

= 0.36 KN-m (moment applied on the Cantilever


Slab Supported Beam)

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 8 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

2.3 Wind Load (WL)

Design Of Wind Load

Basic Wind Speed Vb = 50 m/s

Risk Cofficient K1 = 1.05

Terrain height and structure Size Factor K2 = 1.05

Topography Factor K3 = 1

Length of Building L = 20 m

Width of Building W = 10 m

Height to parapet h = 8.85 m

Design Wind Speed = Vb X K1 X K2 X K3

55.125 m/s

2
Design Wind Pressure Pz = 0.6 Vz

2
Pz = 1823.259 N/m

2
1.823259 KN/m
Consider the wind acting on the longitudinal face of building

External pressure Co-efficient

From Code IS : 875 (part 3)- 1987 table 4

A B
Windward Leeward
Side Side

D
h/w = 0.885 =

l/w = 2

1/2<h/w <1.5

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 9 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

3/2 < l/w < 4

Wind Angle = 0'


A = 0.7
B = -0.3

Wind Angle = 90'


C = 0.7
D = -0.1

Load Case wind Angle = 0' (Internal suction)

B C

0.7 -0.5 -0.3


1.2 0.2

A D

influence width = 2.5 m

FORCE ON END COLUMN

Force on member AB= pressure coefficient x A x wind pressure

= 1.2x2.5x1.823

5.469778 Kn/m

Force on member CD= pressure coefficient x A x wind pressure

= 0.2x2.5x1.823

0.91163 Kn/m
Force on column next to stair case column

influence width = 2.5+2.4/2 3.7


Force on member CD= pressure coefficient x A x wind pressure

0.2x3.7X1.823
1.349212 KN/m

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 10 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

Force on Stair Case Column

influence width = 1.2

Force on member AB= pressure coefficient x A x wind pressure

= 1.2*1.2*1.823
2.625494 KN/m

Force on member CD= pressure coefficient x A x wind pressure

0.2*1.2*1.823
0.437582 KN/m

FORCE ON MIDDLE COLUMN


influence width = 5m

Force on member AB= pressure coefficient x A x wind pressure

= 1.2x5x1.823

10.93956 KN/m

Force on member CD= pressure coefficient x A x wind pressure

0.2x5X1.823
1.823259 KN/m

Load Case wind Angle = 90' (Internal suction)

B C

0.7 -0.5 -0.1

1.2 0.4
A D

FORCE ON END COLUMN


influence width = 2.5 m

Force on member AB = pressure coefficient x A x wind pressure

1.2x2.5x1.823

5.469778 KN/m

Force on member CD = 0.4 *2.5*1.412

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 11 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

1.823259 KN/m
FORCE ON MIDDLE COLUMN

influence width = 5m

Force on member AB = pressure coefficient x A x wind pressure

1.2x5x1.823

10.93956 KN/m

Force on member CD = 0.4 *5*1.823

3.646519 KN/m

FORCE ON STAIR COLUMN


influence width = 2.5 m

Force on member CD = pressure coefficient x A x wind pressure

0.4x2.5x1.823

1.823259 KN/m

Load Case wind Angle = 0' (Internal pressure)

B C

0.7 +0.5 -0.25

0.2 0.75
A D

FORCE ON END COLUMN


influence width = 2.5 m

Force on member AB= pressure coefficient x A x wind pressure

0.2x2.5x1.823

0.91163 KN/m

Force on member CD= pressure coefficient x A x wind pressure

0.75x2.5x1.823

3.418611 KN/m

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 12 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

FORCE ON MIDDLE COLUMN


influence width = 5m

Force on member AB= pressure coefficient x A x wind pressure

0.2x5x1.823

1.823259 KN/m

Force on member CD= pressure coefficient x A x wind pressure

0.75x5x1.823

6.837223 KN/m

FORCE ON COLUMN NEXT TO STAIR


influence width = 2.5+1.2
3.7 m

Force on member AB= pressure coefficient x A x wind pressure

0.2x3.7x1.823

1.349212 KN/m

Force on member CD= pressure coefficient x A x wind pressure

0.75x3.7x1.823

5.059545 KN/m
FORCE ON STAIR COLUMN

influence width = 1.2 m

Force on member AB= pressure coefficient x A x wind pressure

0.2x1.2x1.823

0.437582 KN/m

Force on member CD= pressure coefficient x A x wind pressure

0.75x1.2x1.823

1.640933 KN/m

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 13 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

Load Case wind Angle = 90' (Internal pressure)

B C

0.7 -0.1
+0.5

0.2 0.6
A D

FORCE ON END COLUMN


influence width = 2.5 m
Force on member AB= pressure coefficient x A x wind pressure

0.2x2.5x1.823

0.91163 kN/m

Force on member CD= pressure coefficient x A x wind pressure

0.6x2.5x1.412

2.734889 KN/m
FORCE ON MIDDLE COLUMN
influence width = 5m
Force on member AB= pressure coefficient x A x wind pressure

0.2x5x1.823

1.823259 kN/m

Force on member CD= pressure coefficient x A x wind pressure

0.6x5x1.823

5.469778 KN/m

FORCE ON STAIR COLUMN

influence width = 2.5

Force on member CD= pressure coefficient x A x wind pressure

0.6x2.5x1.823

2.734889 KN/m

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 14 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

Wind Load on Parapet Wall

` 1m
Acting on the wall

Wind Load on wall = Cf x Qp

1.2 x 1.82

= 2.184 KN/m (Applied horizontal UDL on beam )

Moment due to Wind on Beam

= 2.184x1x1/2

= 1.092 KN-m

2.4 Seismic Load


Seismic design is carried out in Staad. Parameters considered are as follows:
Zone IV = 0.24
Importance factor = 1.5
Response Reduction Factor (RF) = 3.0
Soil Site Factor (SS) = 1.0 (Rock)
Structure Type (ST) = 1.0 (RC Building)
Damping Ratio (DM ) = 0.05

2.5 Load Combination

Factored Load
1.5DL+1.5LL
1.5DL+ 1.5EQ:+X
1.5DL+ 1.5EQ:+Z
0.9DL+ 1.5EQ:+X
0.9DL+ 1.5EQ:+Z
1.5DL+ 1.5WL:+Z (0' IS)
1.5DL+ 1.5WL:+Z (0' IP)
1.5DL+ 1.5WL:+X (90' IS)
1.5DL+ 1.5WL:+X (90'IP)
0.9DL+ 1.5WL:+Z(0' IS)
0.9DL+ 1.5WL:+Z(0' IP)
0.9DL+ 1.5WL:+X(90' IS)
0.9DL+ 1.5WL:+X(90' IP)
1.2DL+1.2LL+1.2EQ:+X

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 15 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

1.2DL+1.2LL+1.2EQ:+Z
1.2DL+1.2LL+1.2WL:+Z(0' IS)
1.2DL+1.2LL+1.2WL:+Z(0' IP)
1.2DL+1.2LL+1.2WL:+X(90' IS)
1.2DL+1.2LL+1.2WL:+X(90' IP)
Un Factored Load
1.0DL+1.0LL
1.0DL+ 1.0EQ:+X
1.0DL+ 1.0EQ:+Z)
1.0DL+ 1.0WL:+Z(0'IS)
1.0DL+ 1.0WL:+Z(0'IP)
1.0DL+ 1.0WL:+X(90'IS)
1.0DL+ 1.0WL:+X(90'IP)
1.0DL+1.0LL+1.0EQ:+X
1.0DL+1.0LL+1.0EQ:+Z
1.0DL+1.0LL+1.0WL:+Z(0'IS)
1.0DL+1.0LL+1.0WL:+Z(0'IP)
1.0DL+1.0LL+1.0WL:+X(90'IS)
1.0DL+1.0LL+1.0WL:+X(90' IP)

Note: Reverse wind and Seismic Force is considered by applying negative sign for the above
load combination in Staad

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 16 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

3.0 Views
3.1 Isometric View

3.2 Node Numbers

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 17 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

3.3 Member numbers

3.4 Column numbers

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 18 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

3.5 Staad Input


STAAD SPACE
START JOB INFORMATION
ENGINEER DATE 01-JULY-07
END JOB INFORMATION
INPUT WIDTH 79
UNIT METER KN
JOINT COORDINATES
1 0 -2.1 0; 2 5 -2.1 0; 3 10 -2.1 0; 4 15 -2.1 0; 6 20 -2.1 0; 7 0 -2.1 5;
8 5 -2.1 5; 9 10 -2.1 5; 10 15 -2.1 5; 12 20 -2.1 5; 13 0 -2.1 10;
14 5 -2.1 10; 15 10 -2.1 10; 16 15 -2.1 10; 18 20 -2.1 10; 19 0 0 0; 20 5 0 0;
21 10 0 0; 22 15 0 0; 23 20 0 0; 25 0 0 5; 26 5 0 5; 27 10 0 5; 28 15 0 5;
29 20 0 5; 31 0 0 10; 32 5 0 10; 33 10 0 10; 34 15 0 10; 35 20 0 10;
37 0 2.85 0; 38 5 2.85 0; 39 10 2.85 0; 40 15 2.85 0; 41 20 2.85 0;
43 0 2.85 5; 48 20 2.85 5; 49 0 2.85 10; 50 5 2.85 10; 51 10 2.85 10;
52 15 2.85 10; 53 20 2.85 10; 55 0 4.05 0; 56 5 4.05 0; 57 10 4.05 0;
58 15 4.05 0; 59 20 4.05 0; 61 0 4.05 5; 62 5 4.05 5; 63 10 4.05 5;
64 15 4.05 5; 65 20 4.05 5; 67 0 4.05 10; 68 5 4.05 10; 69 10 4.05 10;
70 15 4.05 10; 71 20 4.05 10; 73 0 0 8; 74 5 0 8; 75 10 0 8; 76 15 0 8;
77 20 0 8; 79 1.87 0 0; 80 1.87 0 5; 81 1.87 0 8; 82 0 6.85 10; 83 5 6.85 10;
84 10 6.85 10; 85 15 6.85 10; 86 20 6.85 10; 88 20 6.85 5; 89 20 6.85 0;
90 0 6.85 0; 91 5 6.85 0; 92 10 6.85 0; 93 15 6.85 0; 95 0 6.85 5;
96 0 8.05 10; 97 5 8.05 10; 98 10 8.05 10; 99 15 8.05 10; 100 20 8.05 10;
102 0 8.05 0; 103 5 8.05 0; 104 10 8.05 0; 105 15 8.05 0; 106 20 8.05 0;
108 0 8.05 5; 109 5 8.05 5; 110 10 8.05 5; 111 15 8.05 5; 112 20 8.05 5;
114 0 4.05 8; 115 5 4.05 8; 116 10 4.05 8; 117 15 4.05 8; 118 20 4.05 8;
120 0 4.05 2.5; 121 5 4.05 2.5; 122 10 4.05 2.5; 123 15 4.05 2.5;
124 20 4.05 2.5; 127 2 4.05 5; 129 2 4.05 8; 131 1.87 0 6.1; 132 5 0 6.1;
135 22.4 -2.1 5; 136 22.4 -2.1 10; 137 22.4 4.05 5; 138 22.4 4.05 10;
139 22.4 8.05 10; 140 22.4 8.05 5; 141 22.4 1.49012e-008 10;
142 22.4 1.49012e-008 5; 143 20 4.05 9; 144 22.4 4.05 9; 145 20 8.05 9;
146 22.4 8.05 9; 147 20 1.575 5; 148 22.4 1.575 5; 149 20 5.5755 5;
150 22.4 5.5755 5; 151 1.5 8.05 5; 152 1.5 8.05 10; 153 20 11.05 10;
154 20 11.05 5; 155 22.4 11.05 10; 156 22.4 11.05 5;
MEMBER INCIDENCES
1 1 19; 2 19 37; 3 37 55; 4 7 25; 5 25 43; 6 43 61; 7 13 31; 8 31 49; 9 49 67;
10 2 20; 11 20 38; 12 38 56; 13 8 26; 14 26 62; 16 14 32; 17 32 50; 18 50 68;
19 3 21; 20 21 39; 21 39 57; 22 9 27; 23 27 63; 25 15 33; 26 33 51; 27 51 69;
28 4 22; 29 22 40; 30 40 58; 31 10 28; 32 28 64; 34 16 34; 35 34 52; 36 52 70;
46 6 23; 47 23 41; 48 41 59; 49 12 29; 50 29 147; 51 48 65; 52 18 35; 53 35 53;
54 53 71; 55 19 79; 56 20 21; 57 21 22; 58 22 23; 60 19 25; 61 25 73; 62 20 26;
63 26 132; 64 21 27; 65 27 75; 66 22 28; 67 28 76; 70 23 29; 71 29 77;
77 73 31; 78 74 32; 79 75 33; 80 76 34; 82 77 35; 83 73 81; 84 74 75; 85 75 76;
86 76 77; 88 25 80; 89 79 20; 90 80 26; 91 79 80; 92 81 74; 93 80 131;
94 49 50; 95 50 51; 96 51 52; 97 52 53; 99 53 48; 100 48 41; 101 37 38;
102 38 39; 103 39 40; 104 40 41; 106 37 43; 107 43 49; 108 67 68; 109 68 69;
110 69 70; 111 70 71; 113 55 56; 114 56 57; 115 57 58; 116 58 59; 118 55 120;
119 61 114; 120 56 121; 121 62 115; 122 57 122; 123 63 116; 124 58 123;
125 64 117; 128 59 124; 129 65 118; 130 61 127; 131 62 63; 132 63 64;
133 64 65; 135 82 83; 136 83 84; 137 84 85; 138 85 86; 140 86 88; 141 88 89;
142 90 91; 143 91 92; 144 92 93; 145 93 89; 147 90 95; 148 95 82; 149 96 152;
150 97 98; 151 98 99; 152 99 100; 154 102 103; 155 103 104; 156 104 105;
157 105 106; 159 102 108; 160 108 96; 161 103 109; 162 109 97; 163 104 110;
164 110 98; 165 105 111; 166 111 99; 169 106 112; 170 112 145; 171 108 151;
172 109 110; 173 110 111; 174 111 112; 176 55 90; 177 90 102; 178 61 95;
179 95 108; 180 67 82; 181 82 96; 182 56 91; 183 91 103; 184 62 109; 185 68 83;
186 83 97; 187 57 92; 188 92 104; 189 63 110; 190 69 84; 191 84 98; 192 58 93;
193 93 105; 194 64 111; 195 70 85; 196 85 99; 202 59 89; 203 89 106;
204 65 149; 205 88 112; 206 71 86; 207 86 100; 208 114 67; 209 115 68;
210 116 69; 211 117 70; 213 118 143; 215 118 117; 216 117 116; 217 116 115;
218 115 129; 219 120 61; 220 121 62; 221 122 63; 222 123 64; 224 124 65;
225 120 121; 226 121 122; 227 122 123; 228 123 124; 231 127 62; 235 129 114;
236 127 129; 239 31 32; 240 32 33; 241 33 34; 242 34 35; 244 26 27; 245 27 28;
246 28 29; 248 131 81; 249 132 74; 250 131 132; 254 135 142; 255 137 150;
256 136 141; 257 138 139; 258 112 140; 259 100 139; 260 71 138; 261 65 137;
262 140 146; 263 137 144; 264 141 138; 265 35 141; 266 142 148; 267 29 142;

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 19 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

268 142 141; 269 143 71; 270 144 138; 272 145 100; 273 146 139; 275 147 48;
276 148 137; 277 147 148; 278 149 88; 279 150 140; 280 149 150; 281 151 109;
282 152 97; 283 151 152; 284 140 156; 285 112 154; 286 100 153; 287 139 155;
288 154 153; 289 156 155; 290 154 156; 291 153 155;
DEFINE MATERIAL START
ISOTROPIC CONCRETE
E 2.5e+007
POISSON 0.2
DENSITY 25
ALPHA 1e-005
DAMP 0.05
END DEFINE MATERIAL
MEMBER RELEASE
91 END MY MZ
93 START MY MZ
84 START MY MZ
84 END MY MZ
85 START MY MZ
85 END MY MZ
86 START MY MZ
86 END MY MZ
92 END MY MZ
83 START MY MZ
215 START MY MZ
215 END MY MZ
216 START MY MZ
216 END MY MZ
217 START MY MZ
217 END MY MZ
218 START MY MZ
235 END MY MZ
91 START MY MZ
226 START MY MZ
226 END MY MZ
227 START MY MZ
227 END MY MZ
228 START MY MZ
228 END MY MZ
248 END MY MZ
250 START MY MZ
250 END MY MZ
277 START MY MZ
277 END MY MZ
280 START MY MZ
280 END MY MZ
225 START MY MZ
225 END MY MZ
236 START MY MZ
236 END MY MZ
********************************************************************************
*PROPERTY
********************************************************************************
MEMBER PROPERTY INDIAN
94 TO 97 99 TO 104 106 107 135 TO 138 140 TO 145 147 148 PRIS YD 0.3 ZD 0.3
149 TO 152 154 TO 157 159 TO 166 169 TO 174 215 TO 218 225 TO 228 235 236 -
250 272 281 TO 283 288 TO 291 PRIS YD 0.5 ZD 0.23
55 TO 58 60 TO 67 70 71 77 TO 80 82 TO 86 88 TO 93 239 TO 242 244 TO 246 248 -
249 PRIS YD 0.5 ZD 0.3
1 TO 14 16 TO 23 25 TO 32 34 TO 36 46 TO 54 176 TO 196 202 TO 207 254 TO 257 -
264 266 275 276 278 279 284 TO 287 PRIS YD 0.35 ZD 0.5
108 TO 111 113 TO 116 118 119 128 TO 133 208 213 219 224 231 -
269 PRIS YD 0.5 ZD 0.3
MEMBER PROPERTY INDIAN
120 TO 125 209 TO 211 220 TO 222 PRIS YD 0.6 ZD 0.23
MEMBER PROPERTY INDIAN
258 TO 263 265 267 268 270 273 277 280 PRIS YD 0.5 ZD 0.3
CONSTANTS

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 20 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

MATERIAL CONCRETE MEMB 1 TO 14 16 TO 23 25 TO 32 34 TO 36 46 TO 58 60 TO 67 -


70 71 77 TO 80 82 TO 86 88 TO 97 99 TO 104 106 TO 111 113 TO 116 118 TO 125 -
128 TO 133 135 TO 138 140 TO 145 147 TO 152 154 TO 157 159 TO 166 -
169 TO 174 176 TO 196 202 TO 211 213 215 TO 222 224 TO 228 231 235 236 239 -
240 TO 242 244 TO 246 248 TO 250 254 TO 270 272 273 275 TO 291
*********************************************************************************
*SUPPORTS
*********************************************************************************
SUPPORTS
1 TO 4 6 TO 10 12 TO 16 18 135 136 FIXED
*********************************************************************************
* SEISMIC LOAD GENERATION
*********************************************************************************
DEFINE 1893 LOAD
ZONE 0.24 RF 3 I 1.5 SS 1 ST 1 DM 0.05
SELFWEIGHT
MEMBER WEIGHT
********************************************************************************
* INNER BRICK WALL 0.23*3.5*20 (3.5M = BELOW BOTTOM OF BEAM)
********************************************************************************
62 TO 67 120 TO 125 220 TO 222 249 UNI 16.1
********************************************************************************
*PARTITION WALL 0.115*3.05*20 = 8.05
93 248 250 UNI 8.05
********************************************************************************
*WALL ABOVE LINTEL 0.23*0.7*20
********************************************************************************
94 TO 97 99 TO 104 106 107 135 TO 138 140 TO 145 147 148 UNI 3.22
********************************************************************************
* PARAPET WALL 1*0.115*20
*OUTER BRICK WALL 0.23*2.5*20
********************************************************************************
56 TO 58 61 70 71 83 TO 86 88 89 91 114 TO 116 118 119 128 129 215 TO 219 -
224 235 UNI 11.5
********************************************************************************
*WEIGHT OF PARTITION WALL (0.115*3.5*20=8.05 KN/m)
236 UNI 8.05
*********************************************************************************
********************************************************************************
*CANTILEVER SLAB AND PARAPET WALL 1*0.115*20
********************************************************************************
108 TO 111 113 TO 116 118 119 128 149 TO 152 154 TO 157 159 160 169 208 219 -
224 282 UNI 6.225
********************************************************************************
*WEIGHT OF WATER TANK
*SLAB + PEDESTAL (0.15*25*2.135*1.5)+(0.2*0.2*0.3*25)*4=13.57
*WEIGHT OF WATER 10 KN
*EMPTY WT OF TANK = 10%OF WATER WT
*WEIGHT OF BEAM = ((2.135*0.2*0.2*25)*2)+((1.5*0.2*0.2*25)*2)=7.27
*TOTAL WT =(10+1++7.27+13.20)/4 =7.86. SAY 8 KN
********************************************************************************
160 283 CON 8 1
160 283 CON 8 2.5
********************************************************************************
* STAIRCASE LOAD
* STAIR WALL UPTO A HT OF 1.08 (BOTTOM OF BEAM (0.23*20*1.08)
********************************************************************************
261 267 UNI 4.83
********************************************************************************
*STAIR OUTER WALL 0.23*3.5*20
********************************************************************************
263 268 270 UNI 16.1
********************************************************************************
*LANDING BEAM- STAIR DEAD LOAD
********************************************************************************
259 260 UNI 16.28
277 280 UNI 16.28

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 21 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

********************************************************************************
*TOP OF LANDING BEAM TO BOTTOM OF FLOOR BEAM (0.3*20*(2.42-0.5))
********************************************************************************
277 280 UNI 8.97
********************************************************************************
*PARAPET AROUND STAIRCASE (0.85*0.1*25)=2.2 kN
********************************************************************************
258 TO 260 262 273 UNI 2.2
********************************************************************************
*STAIR HEAD ROOM
*********************************************************************************
170 258 259 262 272 273 UNI 5.75
*LIVE LOAD 50%
********************************************************************************
*0.5*11.53=5.765
259 260 277 280 UNI 5.765
********************************************************************************
*CANTILEVER SLAB
*0.5*1.05=0.525
********************************************************************************
108 TO 111 113 TO 116 118 119 128 129 149 TO 152 154 TO 157 159 160 169 170 -
208 213 219 224 269 272 282 UNI 0.525
********************************************************************************
*SLAB DEAD LOAD
********************************************************************************
FLOOR WEIGHT
YRANGE 4.05 4.05 FLOAD 3.75 XRANGE 0 20 ZRANGE 0 10
YRANGE 8.05 8.05 FLOAD 5.75 XRANGE 0 20 ZRANGE 0 10
********************************************************************************
*STAIR HEAD ROOM
********************************************************************************
YRANGE 11.05 11.05 FLOAD -5.75 XRANGE 20 22.4 ZRANGE 5 10
********************************************************************************
* SLAB LIVE LOAD FOR FIRST FLOOR ROOF 50%
*0.5*7.36=3.68
********************************************************************************
YRANGE 4.05 4.05 FLOAD 3.68 XRANGE 0 20 ZRANGE 0 10
********************************************************************************
*SESMIC IN X-DIR
********************************************************************************
LOAD 1 LOADTYPE Seismic TITLE EQX
1893 LOAD X
PERFORM ANALYSIS
CHANGE
********************************************************************************
*SESMIC IN Z-DIR
********************************************************************************
LOAD 2 LOADTYPE Seismic TITLE EQZ
1893 LOAD Z
PERFORM ANALYSIS
CHANGE
********************************************************************************
*DEAD LOAD
********************************************************************************
LOAD 3 LOADTYPE Dead TITLE DEAD LOAD
SELFWEIGHT Y -1
FLOOR LOAD
YRANGE 4.05 4.05 FLOAD -3.75 XRANGE 0 20 ZRANGE 0 10 GY
YRANGE 8.05 8.05 FLOAD -5.75 XRANGE 0 20 ZRANGE 0 10 GY
********************************************************************************
*STAIR HEAD ROOM
********************************************************************************
YRANGE 11.05 11.05 FLOAD -5.75 XRANGE 20 22.4 ZRANGE 5 10 GY
MEMBER LOAD
********************************************************************************
* INNER BRICK WALL 0.23*3.5*20 (3.5M = BELOW BOTTOM OF BEAM)
********************************************************************************

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 22 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

62 TO 67 120 TO 125 220 TO 222 249 UNI GY -16.1


********************************************************************************
*PARTITION WALL 0.115*3.05*20 = 8.05
93 248 250 UNI GY -8.05
********************************************************************************
*WALL ABOVE LINTEL 0.23*0.7*20
********************************************************************************
94 TO 97 99 TO 104 106 107 135 TO 138 140 TO 145 147 148 UNI GY -3.22
********************************************************************************
*OUTER BRICK WALL 0.23*2.5*20
********************************************************************************
56 TO 58 61 70 71 83 TO 86 88 89 91 113 TO 116 118 119 128 129 215 TO 219 -
224 235 UNI GY -11.5
********************************************************************************
*WEIGHT OF PARTITION WALL (0.115*3.5*20=8.05 KN/m)
236 UNI GY -8.05
********************************************************************************
*CANTILEVER SLAB AND PARAPET WALL 1*0.115*20
********************************************************************************
108 TO 111 113 TO 116 118 119 128 149 TO 152 154 TO 157 159 160 169 208 219 -
224 282 UNI GY -6.225
108 TO 111 149 TO 152 282 UMOM GX 2.94
113 TO 116 154 TO 157 UMOM GX -2.94
118 119 159 160 208 219 UMOM GZ 2.94
128 169 224 UMOM GZ -2.94
*********************************************************************************
*WEIGHT OF WATER TANK
*SLAB + PEDESTAL (0.15*25*2.135*1.5)+(0.2*0.2*0.3*25)*4=13.57
*WEIGHT OF WATER 10 KN
*EMPTY WT OF TANK = 10%OF WATER WT
*WEIGHT OF BEAM = ((2.135*0.2*0.2*25)*2)+((1.5*0.2*0.2*25)*2)=7.27
*TOTAL WT =(10+1++7.27+13.20)/4 =7.86. SAY 8 KN
*********************************************************************************
160 283 CON GY -8 1 0
160 283 CON GY -8 2.5
*********************************************************************************
* STAIRCASE LOAD
* STAIR WALL UPTO A HT OF 1.08 (BOTTOM OF BEAM (0.23*20*1.08)
*********************************************************************************
261 267 UNI GY -4.83
*********************************************************************************
*STAIR OUTER WALL 0.23*3.5*20
*********************************************************************************
263 268 270 UNI GY -16.1
*********************************************************************************
*LANDING BEAM- STAIR DEAD LOAD
*********************************************************************************
259 260 UNI GY -16.28
277 280 UNI GY -16.28
*********************************************************************************
*TOP OF LANDING BEAM TO BOTTOM OF FLOOR BEAM (0.3*20*(2.42-0.5))
*********************************************************************************
277 280 UNI GY -8.97
*********************************************************************************
*PARAPER AROUND STAIRCASE (0.85*0.1*25)=2.2 kN
*********************************************************************************
258 TO 260 262 273 UNI GY -2.2
*********************************************************************************
*STAIR HEAD ROOM
*********************************************************************************
170 258 259 262 272 273 UNI GY -5.75
*********************************************************************************
*LIVE LOAD
*********************************************************************************
LOAD 4 LOADTYPE Live TITLE LIVE LOAD
FLOOR LOAD
YRANGE 4.05 4.05 FLOAD -7.37 XRANGE 0 20 ZRANGE 0 10 GY

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 23 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

YRANGE 8.05 8.05 FLOAD -1.5 XRANGE 0 20 ZRANGE 0 10 GY


YRANGE 11.05 11.05 FLOAD -1.5 XRANGE 20 22.4 ZRANGE 5 10 GY
MEMBER LOAD
*********************************************************************************
* STAIRCASE LOAD
*********************************************************************************
259 260 277 280 UNI GY -11.95
*********************************************************************************
*CANTILEVER SLAB
*********************************************************************************
108 TO 111 149 TO 152 189 278 282 UMOM GX 0.36
113 TO 116 154 TO 157 UMOM GX -0.36
118 119 159 160 208 219 UMOM GZ 0.36
128 169 224 UMOM GZ -0.36
108 TO 111 113 TO 116 118 119 128 129 149 TO 152 154 TO 157 159 160 169 170 -
208 213 219 224 269 272 282 UNI GY -1.05
*********************************************************************************
*WIND LOAD 0 DEGREE (INTERNAL SUCTION)
*********************************************************************************
LOAD 5 LOADTYPE None TITLE WIND 0' (INTENAL SUCTION WL:+Z(0'IS)
MEMBER LOAD
17 18 26 27 35 36 185 186 190 191 195 196 UNI GZ -1.823
11 12 20 21 29 30 182 183 187 188 192 193 UNI GZ 10.94
*********************************************************************************
*MOMENT DUE TO WIND ON PARAPET
*********************************************************************************
108 TO 111 113 TO 116 149 TO 152 154 TO 157 282 290 291 UMOM GX 1.092
*********************************************************************************
*FORCE DUE TO WIND ON PARAPET
*********************************************************************************
108 TO 111 113 TO 116 149 TO 152 154 TO 157 282 290 291 UNI GZ 2.184
8 9 180 181 UNI GZ -0.912
2 3 47 48 176 177 202 203 UNI GZ 5.46
53 54 206 207 UNI GZ -1.34
257 264 UNI GZ -0.43
255 266 276 279 284 285 UNI GZ 2.62
*********************************************************************************
*WIND LOAD 0 DEGREE (INTERNAL PRESSURE)
*********************************************************************************
LOAD 6 LOADTYPE None TITLE WIND 0' (INTERNAL PRESSURE WL:+Z(0'IP)
MEMBER LOAD
17 18 26 27 35 36 185 186 190 191 195 196 UNI GZ 6.84
11 12 20 21 29 30 182 183 187 188 192 193 UNI GZ 1.82
*********************************************************************************
*MOMENT DUE TO WIND ON PARAPET
*********************************************************************************
108 TO 111 113 TO 116 149 TO 152 154 TO 157 282 290 291 UMOM GX 1.092
*FORCE DUE TO WIND ON PARAPET
108 TO 111 113 TO 116 149 TO 152 154 TO 157 282 290 291 UNI GZ 2.184
8 9 180 181 UNI GZ 3.42
2 3 47 48 176 177 202 203 UNI GZ 0.92
53 54 206 207 UNI GZ 5.06
257 264 UNI GZ 1.64
255 266 276 279 284 285 UNI GZ 0.43
*********************************************************************************
*WIND LOAD 90 DEGREE (INTERNAL SUCTION)
*********************************************************************************
LOAD 7 LOADTYPE None TITLE WIND 90 (INTERNAL SUCTION WL:+X(90'IS)
MEMBER LOAD
5 6 178 179 UNI GX 10.94
50 51 204 205 275 278 UNI GX -3.64
********************************************************************************
*MOMENT DUE TO WIND ON PARAPET
********************************************************************************
118 119 128 129 159 160 169 170 208 213 219 224 269 272 288 289 UMOM GZ -1.092
*FORCE DUE TO WIND ON PARAPET
118 119 128 129 159 160 169 170 208 213 219 224 269 272 288 289 UNI GX 2.184

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 24 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

2 3 8 9 176 177 180 181 UNI GX 5.46


47 48 53 54 202 203 206 207 UNI GX -1.82
255 257 264 266 276 279 284 287 UNI GX -1.823
*********************************************************************************
*WIND LOAD 0 DEGREE (INTERNAL PRESSURE)
*********************************************************************************
LOAD 8 LOADTYPE None TITLE WIND 90 (INTERNAL PRESSURE WL:+X(90'IP)
MEMBER LOAD
5 6 178 179 UNI GX 1.823
50 51 204 205 275 278 UNI GX 5.47
*********************************************************************************
*MOMENT DUE TO WIND ON PARAPET
*********************************************************************************
118 119 128 129 159 160 169 170 208 213 219 224 269 272 288 289 UMOM GZ -1.092
*********************************************************************************
*FORCE DUE TO WIND ON PARAPET
*********************************************************************************
118 119 128 129 159 160 169 170 208 213 219 224 269 272 288 289 UNI GX 2.184
2 3 8 9 176 177 180 181 UNI GX 0.91
47 48 53 54 202 203 206 207 UNI GX 2.74
255 257 264 266 276 279 285 286 UNI GX 2.74
*********************************************************************************
*LOAD COMBINATION
*********************************************************************************
LOAD COMB 9 (1.5DL+1.5LL)
3 1.5 4 1.5
LOAD COMB 10 (1.5DL+ 1.5EQ:+X)
3 1.5 1 1.5
LOAD COMB 11 (1.5DL+ 1.5EQ:+Z)
3 1.5 2 1.5
LOAD COMB 12 (0.9DL+ 1.5EQ:+X)
3 0.9 1 1.5
LOAD COMB 13 (0.9DL+ 1.5EQ:+Z)
3 0.9 2 1.5
LOAD COMB 14 (1.5DL+ 1.5WL:+Z(0'IS))
3 1.5 5 1.5
LOAD COMB 15 (1.5DL+ 1.5WL:+Z(0'IP))
3 1.5 6 1.5
LOAD COMB 16 (1.5DL+ 1.5WL:+X(90'IS))
3 1.5 7 1.5
LOAD COMB 17 (1.5DL+ 1.5WL:+X(90'IP))
3 1.5 8 1.5
LOAD COMB 18 (0.9DL+ 1.5WL:+Z(0'IS))
3 0.9 5 1.5
LOAD COMB 19 (0.9DL+ 1.5WL:+Z(0'IP))
3 0.9 6 1.5
LOAD COMB 20 (0.9DL+ 1.5WL:+X(90'IS))
3 0.9 7 1.5
LOAD COMB 21 (0.9DL+ 1.5WL:+X(90'IP))
3 0.9 8 1.5
LOAD COMB 22 (1.2DL+1.2LL+1.2EQ:+X)
3 1.2 4 1.2 1 1.2
LOAD COMB 23 (1.2DL+1.2LL+1.2EQ:+Z)
3 1.2 4 1.2 2 1.2
LOAD COMB 24 (1.2DL+1.2LL+1.2WL:+Z(0'IS))
3 1.2 4 1.2 5 1.2
LOAD COMB 25 (1.2DL+1.2LL+1.2WL:+Z(0'IP))
3 1.2 4 1.2 6 1.2
LOAD COMB 26 (1.2DL+1.2LL+1.2WL:+X(90'IS))
3 1.2 4 1.2 7 1.2
LOAD COMB 27 (1.2DL+1.2LL+1.2WL:+X(90'IP))
3 1.2 4 1.2 8 1.2
LOAD COMB 28 (1.5DL+1.5EQ:-X)
3 1.5 -1 1.5
LOAD COMB 29 (1.5DL+1.5EQ:-Z)
3 1.5 -2 1.5
LOAD COMB 30 (0.9DL+1.5EQ:-X)

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 25 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

3 0.9 -1 1.5
LOAD COMB 31 (0.9DL+1.5EQ:+Z )
3 0.9 -2 1.5
LOAD COMB 32 (1.5DL+ 1.5WL:-Z(0'IS))
3 1.5 -5 1.5
LOAD COMB 33 (1.5DL+ 1.5WL:-Z(0'IP))
3 1.5 -6 1.5
LOAD COMB 34 (1.5DL+ 1.5WL:-X(90'IS))
3 1.5 -7 1.5
LOAD COMB 35 (1.5DL+ 1.5WL:-X(90'IP))
3 1.5 -8 1.5
LOAD COMB 36 (0.9DL+ 1.5WL:-Z(0'IS))
3 0.9 -5 1.5
LOAD COMB 37 (0.9DL+ 1.5WL:-Z(0'IP))
3 0.9 -6 1.5
LOAD COMB 38 (0.9DL+ 1.5WL:-X(90'IS))
3 0.9 -7 1.5
LOAD COMB 39 (0.9DL+ 1.5WL:-X(90'IP))
3 0.9 -8 1.5
LOAD COMB 40 (1.2DL+1.2LL+1.2EQ:-X)
3 1.2 4 1.2 -1 1.2
LOAD COMB 41 (1.2DL+1.2LL+1.2EQ:-Z)
3 1.2 4 1.2 -2 1.2
LOAD COMB 42 (1.2DL+1.2LL+1.2WL:-Z(0'IS))
3 1.2 4 1.2 -5 1.2
LOAD COMB 43 (1.2DL+1.2LL+1.2WL:-Z(0'IP))
3 1.2 4 1.2 -6 1.2
LOAD COMB 44 (1.2DL+1.2LL+1.2WL:-X(90'IS))
3 1.2 4 1.2 -7 1.2
LOAD COMB 45 (1.2DL+1.2LL+1.2WL:-X(90'IP))
3 1.2 4 1.2 -8 1.2
************************************************************************************
*UNFACTORED LOAD
************************************************************************************
*LOAD COMB 9 (1.0DL+1.0LL)
*3 1.0 4 1.0
*LOAD COMB 10 (1.0DL+ 1.0EQ:+X)
*3 1.0 1 1.0
*LOAD COMB 11 (1.0DL+ 1.0EQ:+Z)
*3 1.0 2 1.0
*LOAD COMB 12 (1.0DL+ 1.0WL:+Z(0'IS))
*3 1.0 5 1.0
*LOAD COMB 13 (1.0DL+ 1.0WL:+Z(0'IP))
*3 1.0 6 1.0
*LOAD COMB 14 (1.0DL+ 1.0WL:+X(90'IS))
*3 1.0 7 1.0
*LOAD COMB 15 (1.0DL+ 1.0WL:+X(90'IP))
*3 1.0 8 1.0
*LOAD COMB 16 (1.0DL+1.0LL+1.0EQ:+X)
*3 1.0 4 1.0 1 1.0
*LOAD COMB 17 (1.0DL+1.0LL+1.0EQ:+Z)
*3 1.0 4 1.0 2 1.0
*LOAD COMB 18 (1.0DL+1.0LL+1.0WL:+Z(0'IS))
*3 1.0 4 1.0 5 1.0
*LOAD COMB 19 (1.0DL+1.0LL+1.0WL:+Z(0'IP))
*3 1.0 4 1.0 6 1.0
*LOAD COMB 20 (1.0DL+1.0LL+1.0WL:+X(90'IS))
*3 1.0 4 1.0 7 1.0
*LOAD COMB 21 (1.0DL+1.0LL+1.0WL:+X(90'IP))
*3 1.2 4 1.0 8 1.0
*LOAD COMB 22 (1.0DL+1.0EQ:-X)
*3 1.0 -1 1.0
*LOAD COMB 23 (1.0DL+1.0EQ:-Z )
*3 1.0 -2 1.0
*LOAD COMB 24 (1.0DL+1.0WL:-Z(0'IS))
*3 1.0 -5 1.0
*LOAD COMB 25 (1.0DL+1.0WL:-Z(0'IP))

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 26 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

*3 1.0 -6 1.0
*LOAD COMB 26 (1.0DL+1.0WL:-X(90'IS))
*3 1.0 -7 1.0
*LOAD COMB 27 (1.0DL+1.0WL:-X(90'IP))
*3 1.0 -8 1.0
*LOAD COMB 28 (1.0DL+1.0LL+1.0EQ:-X)
*3 1.0 4 1.0 -1 1.0
*LOAD COMB 29 (1.0DL+1.0LL+1.0EQ:-Z)
*3 1.0 4 1.0 -2 1.0
*LOAD COMB 30 (1.0DL+1.0LL+1.0WL:-Z(0'IS))
*3 1.0 4 1.0 -5 1.0
*LOAD COMB 31 (1.0DL+1.0LL+1.0WL:-Z(0'IP))
*3 1.0 4 1.0 -6 1.0
*LOAD COMB 32 (1.0DL+1.0LL+1.0WL:-X(90'IS))
*3 1.0 4 1.0 -7 1.0
*LOAD COMB 33 (1.0DL+1.0LL+1.0WL:-X(90'IP))
*3 1.0 4 1.0 -8 1.0
***********************************************************************************
PERFORM ANALYSIS
PRINT MEMBER SECTION FORCES LIST 1 TO 13 16 TO 22 25 TO 31 34 TO 36 -
46 TO 58 60 TO 67 70 71 77 TO 80 82 TO 86 88 TO 97 99 TO 104 106 107 109 -
110 TO 111 114 TO 116 118 TO 120 122 TO 125 128 TO 133 135 TO 138 140 TO 145 -
147 TO 152 154 TO 157 159 TO 166 169 TO 174 176 TO 196 202 TO 211 213 215 -
216 TO 222 224 226 TO 228 231 235 239 TO 242 244 TO 246 248 TO 250 -
254 TO 270 272 273 275 TO 283
***********************************************************************************
*CONCRETE DESIGN
***********************************************************************************
START CONCRETE DESIGN
CODE INDIAN
FC 25000 ALL
FYMAIN 415000 ALL
TRACK 0 MEMB 1 TO 14 16 TO 23 25 TO 32 34 TO 36 46 TO 54 176 TO 196 -
202 TO 207 254 TO 257 264 266 275 276 278 279 284 TO 287
**********************************************************************************
* COLUMN DESIGN
**********************************************************************************
DESIGN COLUMN 1 TO 14 16 TO 23 25 TO 32 34 TO 36 46 TO 54 176 TO 196 -
202 TO 207 254 TO 257 264 266 275 276 278 279 284 TO 287
**********************************************************************************
*BEAM DESIGN
**********************************************************************************
DESIGN BEAM 55 TO 58 60 TO 67 70 71 77 TO 80 82 TO 86 88 TO 97 99 TO 104 106 -
107 109 TO 111 114 TO 116 118 TO 120 122 TO 125 128 TO 133 135 TO 138 140 -
141 TO 145 147 TO 152 154 TO 157 159 TO 166 169 TO 174 208 TO 211 213 215 -
216 TO 222 224 226 TO 228 231 235 236 239 TO 242 244 TO 246 248 TO 250 258 -
259 TO 263 265 267 TO 270 272 273 277 280 TO 283 288 TO 291
END CONCRETE DESIGN
FINISH

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 27 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

3.6 Support Reaction Summary


UnFactored Load

Moment-X Moment-Y Moment-Z


Node L/C Force-X kN Force-Y kN Force-Z kN kNm kNm kNm
1 9 13.668 424.475 1.586 2.465 0.009 -8.76
10 -34.501 243.776 2.114 2.944 -0.403 70.472
11 12.985 239.357 -47.996 -100.604 0.68 -7.649
12 13.523 317.67 -18.534 -39.826 0.79 -8.527
13 13.63 318.978 -18.756 -38.831 0.786 -8.7
14 5.117 341.118 2.168 3.076 -0.287 6.061
15 2.793 335.793 1.477 1.762 -0.621 8.984
16 -34.487 308.509 1.823 2.919 -0.369 70.422
17 13 304.09 -48.287 -100.629 0.714 -7.698
18 13.538 382.404 -18.825 -39.851 0.824 -8.576
19 13.644 383.711 -19.046 -38.856 0.82 -8.75
20 5.131 405.851 1.877 3.051 -0.253 6.012
21 5.538 472.474 1.562 2.235 -0.592 7.193
22 -34.501 243.776 2.114 2.944 -0.403 70.472
23 12.985 239.357 -47.996 -100.604 0.68 -7.649
24 13.523 317.67 -18.534 -39.826 0.79 -8.527
25 13.63 318.978 -18.756 -38.831 0.786 -8.7
26 5.117 341.118 2.168 3.076 -0.287 6.061
27 2.793 335.793 1.477 1.762 -0.621 8.984
28 -34.487 308.509 1.823 2.919 -0.369 70.422
29 13 304.09 -48.287 -100.629 0.714 -7.698
30 13.538 382.404 -18.825 -39.851 0.824 -8.576
31 13.644 383.711 -19.046 -38.856 0.82 -8.75
32 5.131 405.851 1.877 3.051 -0.253 6.012
33 2.807 400.526 1.187 1.737 -0.587 8.935

2 9 -5.168 689.487 7.738 6.277 -0.093 3.788


10 -78.881 582.596 10.322 7.172 0.172 100.108
11 -6.23 450.145 -41.314 -102.586 0.637 5.137
12 -5.413 517.281 -15.768 -50.191 0.913 4.071
13 -5.252 518.415 -17.67 -49.141 0.799 3.863
14 -19.683 572.04 10.421 7.372 -0.037 22.383
15 -21.9 572.282 10.447 7.403 -0.145 25.434
16 -78.809 703.063 7.599 6.017 0.124 100.027
17 -6.157 570.611 -44.037 -103.741 0.59 5.057
18 -5.34 637.747 -18.491 -51.346 0.865 3.991
19 -5.179 638.881 -20.392 -50.296 0.751 3.782
20 -19.611 692.506 7.698 6.217 -0.085 22.303
21 -22.875 806.552 9.817 7.735 -0.202 26.127
22 -78.881 582.596 10.322 7.172 0.172 100.108
23 -6.23 450.145 -41.314 -102.586 0.637 5.137
24 -5.413 517.281 -15.768 -50.191 0.913 4.071
25 -5.252 518.415 -17.67 -49.141 0.799 3.863
26 -19.683 572.04 10.421 7.372 -0.037 22.383
27 -21.9 572.282 10.447 7.403 -0.145 25.434
28 -78.809 703.063 7.599 6.017 0.124 100.027
29 -6.157 570.611 -44.037 -103.741 0.59 5.057
30 -5.34 637.747 -18.491 -51.346 0.865 3.991
31 -5.179 638.881 -20.392 -50.296 0.751 3.782

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 28 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

32 -19.611 692.506 7.698 6.217 -0.085 22.303


33 -21.827 692.748 7.725 6.249 -0.193 25.353

3 9 -0.128 669.823 8.502 7.391 -0.024 0.392


10 -70.529 550.235 11.314 8.517 -0.073 94.455
11 -1.07 423.709 -43.591 -108.314 0.182 1.63
12 -0.254 492.156 -18.003 -55.614 0.018 0.557
13 -0.103 493.47 -19.861 -54.369 0.023 0.356
14 -13.467 550.196 11.326 8.538 -0.11 18.004
15 -16.097 550.375 11.306 8.502 -0.239 21.525
16 -70.507 669.633 8.481 7.346 -0.061 94.428
17 -1.048 543.108 -46.424 -109.484 0.193 1.603
18 -0.232 611.554 -20.836 -56.785 0.029 0.53
19 -0.081 612.868 -22.694 -55.539 0.034 0.329
20 -13.445 669.595 8.493 7.367 -0.099 17.977
21 -16.105 779.859 10.74 9.044 -0.234 21.582
22 -70.529 550.235 11.314 8.517 -0.073 94.455
23 -1.07 423.709 -43.591 -108.314 0.182 1.63
24 -0.254 492.156 -18.003 -55.614 0.018 0.557
25 -0.103 493.47 -19.861 -54.369 0.023 0.356
26 -13.467 550.196 11.326 8.538 -0.11 18.004
27 -16.097 550.375 11.306 8.502 -0.239 21.525
28 -70.507 669.633 8.481 7.346 -0.061 94.428
29 -1.048 543.108 -46.424 -109.484 0.193 1.603
30 -0.232 611.554 -20.836 -56.785 0.029 0.53
31 -0.081 612.868 -22.694 -55.539 0.034 0.329
32 -13.445 669.595 8.493 7.367 -0.099 17.977
33 -16.075 669.774 8.473 7.332 -0.227 21.498

4 9 0.306 678.154 8.524 7.128 0.101 0.096


10 -73.094 545.621 11.686 9.108 0.27 96.156
11 -0.627 431.332 -43.18 -107.474 -0.211 1.296
12 0.271 503.776 -15.624 -50.702 -0.772 0.16
13 0.429 505.259 -17.577 -49.715 -0.689 -0.044
14 -13.244 555.495 11.407 8.588 0.086 17.692
15 -16.49 554.634 11.3 8.39 -0.018 21.82
16 -73.104 665.932 8.938 7.89 0.32 96.171
17 -0.636 551.643 -45.928 -108.691 -0.16 1.31
18 0.261 624.086 -18.373 -51.92 -0.722 0.175
19 0.419 625.57 -20.325 -50.933 -0.639 -0.03
20 -13.254 675.806 8.659 7.371 0.137 17.706
21 -16.437 786.514 10.806 8.842 0.042 21.851
22 -73.094 545.621 11.686 9.108 0.27 96.156
23 -0.627 431.332 -43.18 -107.474 -0.211 1.296
24 0.271 503.776 -15.624 -50.702 -0.772 0.16
25 0.429 505.259 -17.577 -49.715 -0.689 -0.044
26 -13.244 555.495 11.407 8.588 0.086 17.692
27 -16.49 554.634 11.3 8.39 -0.018 21.82
28 -73.104 665.932 8.938 7.89 0.32 96.171
29 -0.636 551.643 -45.928 -108.691 -0.16 1.31
30 0.261 624.086 -18.373 -51.92 -0.722 0.175
31 0.419 625.57 -20.325 -50.933 -0.639 -0.03
32 -13.254 675.806 8.659 7.371 0.137 17.706
33 -16.5 674.945 8.552 7.173 0.032 21.834

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 29 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

6 9 -8.94 448.221 9.42 6.702 0.05 6.266


10 -58.034 496.893 9.702 8.04 -0.636 86.043
11 -9.562 242.216 -45.591 -108.289 -0.022 7.243
12 -8.921 335.567 -11.048 -36.729 -0.845 6.276
13 -8.814 338.998 -12.325 -37.116 -0.717 6.106
14 -18.5 401.846 9.741 7.118 -0.218 21.075
15 -19.842 406.671 10.06 7.838 -0.763 24.123
16 -58.066 561.814 9.484 8.007 -0.605 86.08
17 -9.594 307.137 -45.809 -108.322 0.01 7.279
18 -8.953 400.487 -11.266 -36.762 -0.814 6.313
19 -8.846 403.919 -12.543 -37.148 -0.685 6.143
20 -18.532 466.766 9.523 7.086 -0.186 21.112
21 -21.656 548.251 11.77 9.152 -0.728 25.405
22 -58.034 496.893 9.702 8.04 -0.636 86.043
23 -9.562 242.216 -45.591 -108.289 -0.022 7.243
24 -8.921 335.567 -11.048 -36.729 -0.845 6.276
25 -8.814 338.998 -12.325 -37.116 -0.717 6.106
26 -18.5 401.846 9.741 7.118 -0.218 21.075
27 -19.842 406.671 10.06 7.838 -0.763 24.123
28 -58.066 561.814 9.484 8.007 -0.605 86.08
29 -9.594 307.137 -45.809 -108.322 0.01 7.279
30 -8.953 400.487 -11.266 -36.762 -0.814 6.313
31 -8.846 403.919 -12.543 -37.148 -0.685 6.143
32 -18.532 466.766 9.523 7.086 -0.186 21.112
33 -19.874 471.591 9.842 7.806 -0.731 24.16

7 9 18.664 689.384 13.778 10.094 0.04 -11.899


10 -20.794 463.886 14.188 10.584 0.129 58.306
11 19.36 567.975 -65.54 -111.906 0.557 -12.092
12 19.377 569.354 -19.655 -40.306 0.379 -12.115
13 19.453 569.277 -18.77 -38.993 0.316 -12.23
14 13.07 551.346 14.225 10.7 0.33 1.77
15 7.07 542.378 13.187 9.164 -0.158 8.797
16 -21.438 583.454 14.264 10.734 0.116 58.424
17 18.717 687.543 -65.464 -111.757 0.543 -11.974
18 18.733 688.923 -19.579 -40.156 0.365 -11.998
19 18.809 688.846 -18.694 -38.844 0.303 -12.112
20 12.426 670.915 14.3 10.849 0.317 1.888
21 10.287 775.91 16.003 11.302 -0.161 6.511
22 -20.794 463.886 14.188 10.584 0.129 58.306
23 19.36 567.975 -65.54 -111.906 0.557 -12.092
24 19.377 569.354 -19.655 -40.306 0.379 -12.115
25 19.453 569.277 -18.77 -38.993 0.316 -12.23
26 13.07 551.346 14.225 10.7 0.33 1.77
27 7.07 542.378 13.187 9.164 -0.158 8.797
28 -21.438 583.454 14.264 10.734 0.116 58.424
29 18.717 687.543 -65.464 -111.757 0.543 -11.974
30 18.733 688.923 -19.579 -40.156 0.365 -11.998
31 18.809 688.846 -18.694 -38.844 0.303 -12.112
32 12.426 670.915 14.3 10.849 0.317 1.888
33 6.426 661.947 13.262 9.314 -0.171 8.915

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 30 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

8 9 -10.402 897.24 10.462 7.45 0.018 7.441


10 -76.621 689.482 10.052 6.957 -0.044 95.357
11 -11.227 668.915 -71.895 -122.185 0.276 8.171
12 -11.259 668.994 -35.415 -61.852 0.483 8.187
13 -11.159 669.316 -33.952 -59.708 0.468 8.057
14 -26.251 673.908 10.296 7.257 0.154 27.321
15 -31.094 675.691 10.323 7.286 -0.099 34.08
16 -75.666 917.173 10.151 7.073 -0.034 94.505
17 -10.273 896.606 -71.796 -122.07 0.287 7.319
18 -10.304 896.684 -35.316 -61.736 0.493 7.335
19 -10.204 897.006 -33.852 -59.593 0.478 7.204
20 -25.296 901.599 10.395 7.372 0.164 26.469
21 -32.411 1037.292 12.495 8.868 -0.088 34.886
22 -76.621 689.482 10.052 6.957 -0.044 95.357
23 -11.227 668.915 -71.895 -122.185 0.276 8.171
24 -11.259 668.994 -35.415 -61.852 0.483 8.187
25 -11.159 669.316 -33.952 -59.708 0.468 8.057
26 -26.251 673.908 10.296 7.257 0.154 27.321
27 -31.094 675.691 10.323 7.286 -0.099 34.08
28 -75.666 917.173 10.151 7.073 -0.034 94.505
29 -10.273 896.606 -71.796 -122.07 0.287 7.319
30 -10.304 896.684 -35.316 -61.736 0.493 7.335
31 -10.204 897.006 -33.852 -59.593 0.478 7.204
32 -25.296 901.599 10.395 7.372 0.164 26.469
33 -30.14 903.382 10.422 7.402 -0.089 33.227

9 9 0.13 834.565 10.82 8.324 0.004 0.343


10 -62.447 607.346 10.655 8.103 0.005 85.608
11 -0.039 609.256 -76.561 -129.402 0.214 0.564
12 -0.069 608.888 -40.071 -68.762 0.046 0.587
13 0.031 609.31 -38.435 -66.357 0.028 0.453
14 -13.015 609.105 10.672 8.127 0.099 17.861
15 -19.116 608.696 10.644 8.086 -0.109 25.973
16 -62.188 832.709 10.784 8.27 0.01 85.293
17 0.22 834.619 -76.432 -129.235 0.218 0.249
18 0.19 834.251 -39.943 -68.596 0.05 0.271
19 0.29 834.673 -38.307 -66.191 0.032 0.138
20 -12.756 834.468 10.801 8.293 0.103 17.546
21 -18.883 955.899 12.911 9.884 -0.105 25.789
22 -62.447 607.346 10.655 8.103 0.005 85.608
23 -0.039 609.256 -76.561 -129.402 0.214 0.564
24 -0.069 608.888 -40.071 -68.762 0.046 0.587
25 0.031 609.31 -38.435 -66.357 0.028 0.453
26 -13.015 609.105 10.672 8.127 0.099 17.861
27 -19.116 608.696 10.644 8.086 -0.109 25.973
28 -62.188 832.709 10.784 8.27 0.01 85.293
29 0.22 834.619 -76.432 -129.235 0.218 0.249
30 0.19 834.251 -39.943 -68.596 0.05 0.271
31 0.29 834.673 -38.307 -66.191 0.032 0.138
32 -12.756 834.468 10.801 8.293 0.103 17.546
33 -18.857 834.059 10.773 8.252 -0.104 25.657

10 9 -0.929 848.047 10.464 7.845 0.041 1.046


10 -62.51 622.848 11.007 8.708 -0.089 85.483

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 31 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

11 -0.854 620.743 -76.115 -128.545 -0.003 1.039


12 -0.918 620.113 -36.349 -62.999 -0.464 1.093
13 -0.81 620.478 -34.986 -60.959 -0.43 0.952
14 -12.906 619.562 10.621 8.106 0.065 17.306
15 -20.17 619.309 10.46 7.879 -0.128 26.74
16 -62.464 850.721 11.037 8.73 -0.082 85.372
17 -0.808 848.616 -76.084 -128.523 0.004 0.928
18 -0.872 847.986 -36.318 -62.977 -0.456 0.982
19 -0.765 848.351 -34.956 -60.937 -0.423 0.841
20 -12.861 847.435 10.652 8.128 0.072 17.195
21 -20.319 971.217 12.577 9.465 -0.114 26.861
22 -62.51 622.848 11.007 8.708 -0.089 85.483
23 -0.854 620.743 -76.115 -128.545 -0.003 1.039
24 -0.918 620.113 -36.349 -62.999 -0.464 1.093
25 -0.81 620.478 -34.986 -60.959 -0.43 0.952
26 -12.906 619.562 10.621 8.106 0.065 17.306
27 -20.17 619.309 10.46 7.879 -0.128 26.74
28 -62.464 850.721 11.037 8.73 -0.082 85.372
29 -0.808 848.616 -76.084 -128.523 0.004 0.928
30 -0.872 847.986 -36.318 -62.977 -0.456 0.982
31 -0.765 848.351 -34.956 -60.937 -0.423 0.841
32 -12.861 847.435 10.652 8.128 0.072 17.195
33 -20.124 847.182 10.49 7.901 -0.12 26.629

12 9 -3.366 766.497 5.646 4.275 0.062 2.711


10 -75.639 397.38 6.417 5.979 0.3 94.196
11 -3.296 594.189 -81.566 -131.153 -0.581 2.634
12 -3.026 609.2 -28.181 -47.239 -0.447 2.473
13 -2.882 610.822 -28.756 -47.626 -0.552 2.304
14 -16.833 573.417 5.861 4.686 0.219 19.535
15 -24.752 550.386 6.361 5.511 0.017 30.018
16 -76.1 548.849 6.525 6.094 0.311 94.491
17 -3.758 745.657 -81.458 -131.037 -0.57 2.929
18 -3.487 760.669 -28.073 -47.124 -0.436 2.767
19 -3.344 762.29 -28.648 -47.511 -0.541 2.598
20 -17.295 724.886 5.969 4.801 0.23 19.829
21 -25.795 824.86 7.577 6.458 0.038 30.796
22 -75.639 397.38 6.417 5.979 0.3 94.196
23 -3.296 594.189 -81.566 -131.153 -0.581 2.634
24 -3.026 609.2 -28.181 -47.239 -0.447 2.473
25 -2.882 610.822 -28.756 -47.626 -0.552 2.304
26 -16.833 573.417 5.861 4.686 0.219 19.535
27 -24.752 550.386 6.361 5.511 0.017 30.018
28 -76.1 548.849 6.525 6.094 0.311 94.491
29 -3.758 745.657 -81.458 -131.037 -0.57 2.929
30 -3.487 760.669 -28.073 -47.124 -0.436 2.767
31 -3.344 762.29 -28.648 -47.511 -0.541 2.598
32 -17.295 724.886 5.969 4.801 0.23 19.829
33 -25.214 701.854 6.469 5.626 0.027 30.312

13 9 2.647 420.592 -14.884 -8.191 0.139 -1.985


10 -42.002 233.906 -15.197 -8.09 0.715 73.312
11 3.183 478.21 -65.077 -111.523 0.691 -2.885
12 2.735 398.239 -36.759 -50.933 0.834 -2.083
13 2.582 397.036 -35.432 -49.729 0.816 -1.836

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 32 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

14 -3.448 337.865 -14.942 -7.842 0.433 9.321


15 -9.984 326.499 -15.63 -9.147 0.377 18.866
16 -41.906 299.028 -14.852 -7.829 0.732 73.149
17 3.279 543.332 -64.732 -111.263 0.708 -3.048
18 2.831 463.361 -36.414 -50.673 0.851 -2.246
19 2.678 462.158 -35.087 -49.469 0.833 -1.999
20 -3.351 402.987 -14.596 -7.582 0.451 9.157
21 -9.377 462.715 -18.33 -10.577 0.418 18.338
22 -42.002 233.906 -15.197 -8.09 0.715 73.312
23 3.183 478.21 -65.077 -111.523 0.691 -2.885
24 2.735 398.239 -36.759 -50.933 0.834 -2.083
25 2.582 397.036 -35.432 -49.729 0.816 -1.836
26 -3.448 337.865 -14.942 -7.842 0.433 9.321
27 -9.984 326.499 -15.63 -9.147 0.377 18.866
28 -41.906 299.028 -14.852 -7.829 0.732 73.149
29 3.279 543.332 -64.732 -111.263 0.708 -3.048
30 2.831 463.361 -36.414 -50.673 0.851 -2.246
31 2.678 462.158 -35.087 -49.469 0.833 -1.999
32 -3.351 402.987 -14.596 -7.582 0.451 9.157
33 -9.887 391.621 -15.284 -8.887 0.394 18.702

14 9 -0.118 592.241 -18.148 -11.296 0.073 -0.088


10 -69.73 486.737 -20.543 -12.555 0.04 91.8
11 0.668 591.355 -72.429 -122.406 0.689 -1.148
12 -0.081 524.22 -50.913 -71.119 0.807 -0.141
13 -0.31 522.747 -47.244 -68.61 0.801 0.158
14 -11.326 474.949 -20.624 -12.452 0.097 14.415
15 -19.664 476.167 -20.583 -12.416 0.058 25.358
16 -69.542 606.983 -18.029 -11.416 0.074 91.581
17 0.856 711.6 -69.915 -121.266 0.723 -1.368
18 0.107 644.466 -48.398 -69.979 0.841 -0.361
19 -0.122 642.992 -44.73 -67.47 0.835 -0.062
20 -11.138 595.194 -18.11 -11.312 0.131 14.195
21 -19.537 690.812 -22.201 -13.763 0.099 25.165
22 -69.73 486.737 -20.543 -12.555 0.04 91.8
23 0.668 591.355 -72.429 -122.406 0.689 -1.148
24 -0.081 524.22 -50.913 -71.119 0.807 -0.141
25 -0.31 522.747 -47.244 -68.61 0.801 0.158
26 -11.326 474.949 -20.624 -12.452 0.097 14.415
27 -19.664 476.167 -20.583 -12.416 0.058 25.358
28 -69.542 606.983 -18.029 -11.416 0.074 91.581
29 0.856 711.6 -69.915 -121.266 0.723 -1.368
30 0.107 644.466 -48.398 -69.979 0.841 -0.361
31 -0.122 642.992 -44.73 -67.47 0.835 -0.062
32 -11.138 595.194 -18.11 -11.312 0.131 14.195
33 -19.476 596.413 -18.068 -11.276 0.091 25.139

15 9 0.153 587.448 -19.843 -11.682 0.017 -0.206


10 -65.975 466.528 -22.548 -12.986 0.198 89.075
11 0.901 594.478 -77.488 -129.809 0.228 -1.224
12 0.153 526.399 -55.983 -78.218 0.074 -0.212
13 -0.069 524.661 -52.125 -75.446 0.055 0.083
14 -9.914 467.608 -22.545 -12.97 0.174 13.298
15 -18.469 467.513 -22.563 -13.006 0.13 24.583
16 -65.864 586.129 -19.857 -11.722 0.195 88.922

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 33 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

17 1.013 714.079 -74.797 -128.546 0.226 -1.377


18 0.265 646 -53.292 -76.954 0.072 -0.365
19 0.043 644.262 -49.434 -74.182 0.053 -0.07
20 -9.802 587.209 -19.854 -11.706 0.172 13.145
21 -18.349 680.684 -24.379 -14.332 0.132 24.419
22 -65.975 466.528 -22.548 -12.986 0.198 89.075
23 0.901 594.478 -77.488 -129.809 0.228 -1.224
24 0.153 526.399 -55.983 -78.218 0.074 -0.212
25 -0.069 524.661 -52.125 -75.446 0.055 0.083
26 -9.914 467.608 -22.545 -12.97 0.174 13.298
27 -18.469 467.513 -22.563 -13.006 0.13 24.583
28 -65.864 586.129 -19.857 -11.722 0.195 88.922
29 1.013 714.079 -74.797 -128.546 0.226 -1.377
30 0.265 646 -53.292 -76.954 0.072 -0.365
31 0.043 644.262 -49.434 -74.182 0.053 -0.07
32 -9.802 587.209 -19.854 -11.706 0.172 13.145
33 -18.357 587.114 -19.872 -11.742 0.128 24.43

16 9 0.221 593.521 -20.088 -12.064 0.022 -0.186


10 -63.855 473.881 -22.269 -12.402 0.103 87.295
11 0.875 599.547 -77.088 -128.981 -0.081 -1.119
12 0.082 527.199 -53.501 -73.242 -0.638 -0.074
13 -0.144 525.339 -49.881 -70.808 -0.611 0.224
14 -9.278 472.079 -22.485 -12.906 0.187 12.692
15 -18.156 471.723 -22.604 -13.105 0.052 24.41
16 -63.704 594.631 -19.762 -11.319 0.067 87.132
17 1.026 720.297 -74.581 -127.898 -0.117 -1.282
18 0.233 647.949 -50.994 -72.16 -0.675 -0.238
19 0.008 646.089 -47.374 -69.725 -0.648 0.061
20 -9.126 592.829 -19.978 -11.823 0.151 12.529
21 -17.991 687.027 -24.616 -14.651 0.028 24.242
22 -63.855 473.881 -22.269 -12.402 0.103 87.295
23 0.875 599.547 -77.088 -128.981 -0.081 -1.119
24 0.082 527.199 -53.501 -73.242 -0.638 -0.074
25 -0.144 525.339 -49.881 -70.808 -0.611 0.224
26 -9.278 472.079 -22.485 -12.906 0.187 12.692
27 -18.156 471.723 -22.604 -13.105 0.052 24.41
28 -63.704 594.631 -19.762 -11.319 0.067 87.132
29 1.026 720.297 -74.581 -127.898 -0.117 -1.282
30 0.233 647.949 -50.994 -72.16 -0.675 -0.238
31 0.008 646.089 -47.374 -69.725 -0.648 0.061
32 -9.126 592.829 -19.978 -11.823 0.151 12.529
33 -18.005 592.473 -20.097 -12.022 0.016 24.246

18 9 -1.973 523.314 -13.906 -8.154 0.051 1.343


10 -78.189 247.438 -13.045 -6.347 0.919 96.334
11 -0.896 580.162 -69.582 -123.3 -0.741 0.155
12 -1.747 475.635 -36.224 -51.995 -0.754 1.224
13 -2.026 470.491 -35.745 -52.216 -0.897 1.561
14 -12.59 394.662 -13.839 -7.782 0.536 14.698
15 -23.203 371.045 -13.499 -7.063 0.311 27.831
16 -78.463 346.102 -12.738 -6.165 0.89 96.466
17 -1.17 678.825 -69.275 -123.118 -0.771 0.287
18 -2.021 574.299 -35.917 -51.813 -0.784 1.356

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 34 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

19 -2.3 569.155 -35.438 -52.034 -0.927 1.693


20 -12.863 493.325 -13.533 -7.6 0.507 14.831
21 -23.817 554.639 -16.035 -8.548 0.298 28.205
22 -78.189 247.438 -13.045 -6.347 0.919 96.334
23 -0.896 580.162 -69.582 -123.3 -0.741 0.155
24 -1.747 475.635 -36.224 -51.995 -0.754 1.224
25 -2.026 470.491 -35.745 -52.216 -0.897 1.561
26 -12.59 394.662 -13.839 -7.782 0.536 14.698
27 -23.203 371.045 -13.499 -7.063 0.311 27.831
28 -78.463 346.102 -12.738 -6.165 0.89 96.466
29 -1.17 678.825 -69.275 -123.118 -0.771 0.287
30 -2.021 574.299 -35.917 -51.813 -0.784 1.356
31 -2.3 569.155 -35.438 -52.034 -0.927 1.693
32 -12.863 493.325 -13.533 -7.6 0.507 14.831
33 -23.477 469.709 -13.192 -6.881 0.282 27.963

135 9 -3.464 361.709 13.082 8.617 0.089 2.8


10 -58.163 632.591 11.241 5.077 1.033 82.438
11 -3.653 194.625 -36.676 -93.786 -0.996 2.862
12 -3.304 283.948 -4.577 -27.777 -0.558 2.651
13 -3.177 288.325 -4.887 -26.675 -0.798 2.492
14 -13.82 383.263 12.031 6.607 0.599 17.425
15 -20.027 415.928 12.838 8.106 0.517 26.881
16 -58.478 666.758 11.179 5.069 1.036 82.662
17 -3.968 228.792 -36.739 -93.794 -0.994 3.085
18 -3.619 318.114 -4.639 -27.785 -0.556 2.874
19 -3.493 322.492 -4.949 -26.683 -0.795 2.716
20 -14.135 417.43 11.969 6.599 0.601 17.648
21 -20.972 515.603 15.405 9.823 0.537 27.62
22 -58.163 632.591 11.241 5.077 1.033 82.438
23 -3.653 194.625 -36.676 -93.786 -0.996 2.862
24 -3.304 283.948 -4.577 -27.777 -0.558 2.651
25 -3.177 288.325 -4.887 -26.675 -0.798 2.492
26 -13.82 383.263 12.031 6.607 0.599 17.425
27 -20.027 415.928 12.838 8.106 0.517 26.881
28 -58.478 666.758 11.179 5.069 1.036 82.662
29 -3.968 228.792 -36.739 -93.794 -0.994 3.085
30 -3.619 318.114 -4.639 -27.785 -0.556 2.874
31 -3.493 322.492 -4.949 -26.683 -0.795 2.716
32 -14.135 417.43 11.969 6.599 0.601 17.648
33 -20.343 450.094 12.776 8.098 0.519 27.105

136 9 -1.301 306.377 -13.154 -8.069 0.1 0.902


10 -62.716 557.23 -15.094 -11.668 0.812 85.703
11 -0.519 412.162 -61.99 -109.875 -0.951 -0.083
12 -1.149 319.736 -31.9 -44.963 -0.408 0.83
13 -1.378 315.454 -30.261 -42.884 -0.672 1.135
14 -10.192 319.917 -14.332 -10.154 0.475 13.005
15 -18.126 353.286 -13.525 -8.654 0.366 24.411
16 -62.896 589.609 -15.026 -11.601 0.824 85.779
17 -0.699 444.54 -61.922 -109.809 -0.939 -0.008
18 -1.329 352.115 -31.832 -44.897 -0.396 0.906
19 -1.558 347.832 -30.193 -42.818 -0.66 1.21
20 -10.372 352.295 -14.264 -10.087 0.487 13.081
21 -18.531 440.464 -16.102 -10.215 0.396 24.652

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 35 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

22 -62.716 557.23 -15.094 -11.668 0.812 85.703


23 -0.519 412.162 -61.99 -109.875 -0.951 -0.083
24 -1.149 319.736 -31.9 -44.963 -0.408 0.83
25 -1.378 315.454 -30.261 -42.884 -0.672 1.135
26 -10.192 319.917 -14.332 -10.154 0.475 13.005
27 -18.126 353.286 -13.525 -8.654 0.366 24.411
28 -62.896 589.609 -15.026 -11.601 0.824 85.779
29 -0.699 444.54 -61.922 -109.809 -0.939 -0.008
30 -1.329 352.115 -31.832 -44.897 -0.396 0.906
31 -1.558 347.832 -30.193 -42.818 -0.66 1.21
32 -10.372 352.295 -14.264 -10.087 0.487 13.081
33 -18.306 385.664 -13.457 -8.588 0.378 24.486

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 36 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

3.7 Column design Summary


C O L U M N N O. 1 DESIGN RESULTS

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2100.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 30 END JOINT: 1 SHORT COLUMN

REQD. STEEL AREA : 2031.63 Sq.mm.


REQD. CONCRETE AREA: 172968.38 Sq.mm.
MAIN REINFORCEMENT : Provide 20 - 12 dia. (1.29%, 2261.95 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2578.24 Muz1 : 113.37 Muy1 : 171.76

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 12
END JOINT: 1 Puz : 2647.33 Muz : 122.39 Muy : 185.93 IR: 0.92
============================================================================

============================================================================

C O L U M N N O. 2 DESIGN RESULTS

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2850.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 30 END JOINT: 19 SHORT COLUMN

STAAD SPACE -- PAGE NO. 15

REQD. STEEL AREA : 2148.30 Sq.mm.


REQD. CONCRETE AREA: 172851.70 Sq.mm.
MAIN REINFORCEMENT : Provide 20 - 12 dia. (1.29%, 2261.95 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2613.24 Muz1 : 118.53 Muy1 : 179.78

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 12
END JOINT: 19 Puz : 2647.33 Muz : 122.93 Muy : 186.74 IR: 0.96
============================================================================

============================================================================

C O L U M N N O. 3 DESIGN RESULTS

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 1200.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 30 END JOINT: 55 SHORT COLUMN

REQD. STEEL AREA : 1216.74 Sq.mm.


REQD. CONCRETE AREA: 152092.56 Sq.mm.
MAIN REINFORCEMENT : Provide 12 - 12 dia. (0.78%, 1357.17 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2333.77 Muz1 : 78.89 Muy1 : 118.23

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 37 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0
WORST LOAD CASE: 12
END JOINT: 55 Puz : 2375.90 Muz : 85.63 Muy : 129.28 IR: 0.92
STAAD SPACE -- PAGE NO. 16

============================================================================

============================================================================

C O L U M N N O. 4 DESIGN RESULTS

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2100.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 31 END JOINT: 7 SHORT COLUMN

REQD. STEEL AREA : 1720.07 Sq.mm.


REQD. CONCRETE AREA: 173279.94 Sq.mm.
MAIN REINFORCEMENT : Provide 16 - 12 dia. (1.03%, 1809.56 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2484.77 Muz1 : 127.08 Muy1 : 190.99

INTERACTION RATIO: 0.99 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 13
END JOINT: 7 Puz : 2511.62 Muz : 130.04 Muy : 195.65 IR: 0.97
============================================================================

============================================================================

C O L U M N N O. 5 DESIGN RESULTS

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2850.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 31 END JOINT: 25 SHORT COLUMN

STAAD SPACE -- PAGE NO. 17

REQD. STEEL AREA : 2258.36 Sq.mm.


REQD. CONCRETE AREA: 172741.64 Sq.mm.
MAIN REINFORCEMENT : Provide 20 - 12 dia. (1.29%, 2261.95 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2646.26 Muz1 : 138.87 Muy1 : 210.48

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 13
END JOINT: 25 Puz : 2647.33 Muz : 139.00 Muy : 210.68 IR: 1.00
============================================================================

============================================================================

C O L U M N N O. 6 DESIGN RESULTS

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 1200.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 30 END JOINT: 61 SHORT COLUMN

REQD. STEEL AREA : 2067.17 Sq.mm.


REQD. CONCRETE AREA: 172932.83 Sq.mm.
MAIN REINFORCEMENT : Provide 20 - 12 dia. (1.29%, 2261.95 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2588.90 Muz1 : 122.97 Muy1 : 186.09

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 38 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0
INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 12
END JOINT: 61 Puz : 2647.33 Muz : 130.09 Muy : 197.38 IR: 0.94
STAAD SPACE -- PAGE NO. 18

============================================================================

============================================================================

C O L U M N N O. 7 DESIGN RESULTS

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2100.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 30 END JOINT: 13 SHORT COLUMN

REQD. STEEL AREA : 2122.26 Sq.mm.


REQD. CONCRETE AREA: 172877.73 Sq.mm.
MAIN REINFORCEMENT : Provide 20 - 12 dia. (1.29%, 2261.95 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2605.43 Muz1 : 115.78 Muy1 : 175.69

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 12
END JOINT: 13 Puz : 2647.33 Muz : 121.29 Muy : 184.30 IR: 0.95
============================================================================

============================================================================

C O L U M N N O. 8 DESIGN RESULTS

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2850.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 30 END JOINT: 31 SHORT COLUMN

STAAD SPACE -- PAGE NO. 19

REQD. STEEL AREA : 2754.75 Sq.mm.


REQD. CONCRETE AREA: 172245.25 Sq.mm.
MAIN REINFORCEMENT : Provide 16 - 16 dia. (1.84%, 3216.99 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2795.18 Muz1 : 140.09 Muy1 : 214.39

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 12
END JOINT: 31 Puz : 2933.85 Muz : 157.14 Muy : 241.71 IR: 0.89
============================================================================

============================================================================

C O L U M N N O. 9 DESIGN RESULTS

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 1200.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 30 END JOINT: 67 SHORT COLUMN

REQD. STEEL AREA : 1550.31 Sq.mm.


REQD. CONCRETE AREA: 173449.69 Sq.mm.
MAIN REINFORCEMENT : Provide 8 - 16 dia. (0.92%, 1608.50 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 39 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0
SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)
----------------------------------------------------------
Puz : 2433.84 Muz1 : 91.29 Muy1 : 137.71

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 12
END JOINT: 67 Puz : 2451.30 Muz : 95.11 Muy : 144.86 IR: 0.96
STAAD SPACE -- PAGE NO. 20

============================================================================

============================================================================

C O L U M N N O. 10 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2100.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 30 END JOINT: 2 SHORT COLUMN

REQD. STEEL AREA : 2559.74 Sq.mm.


REQD. CONCRETE AREA: 172440.27 Sq.mm.
MAIN REINFORCEMENT : Provide 24 - 12 dia. (1.55%, 2714.34 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2736.67 Muz1 : 155.60 Muy1 : 236.82

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 12
END JOINT: 2 Puz : 2783.05 Muz : 160.95 Muy : 245.30 IR: 0.96
============================================================================

============================================================================

C O L U M N N O. 11 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2850.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 20 SHORT COLUMN

STAAD SPACE -- PAGE NO. 21

REQD. STEEL AREA : 3980.17 Sq.mm.


REQD. CONCRETE AREA: 171019.83 Sq.mm.
MAIN REINFORCEMENT : Provide 20 - 16 dia. (2.30%, 4021.24 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 3162.80 Muz1 : 201.88 Muy1 : 312.83

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 20 Puz : 3175.12 Muz : 203.11 Muy : 314.87 IR: 0.99
============================================================================

============================================================================

C O L U M N N O. 12 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 1200.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 56 SHORT COLUMN

REQD. STEEL AREA : 3065.95 Sq.mm.


REQD. CONCRETE AREA: 171934.05 Sq.mm.

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 40 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0
MAIN REINFORCEMENT : Provide 16 - 16 dia. (1.84%, 3216.99 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2888.53 Muz1 : 172.80 Muy1 : 265.11

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 56 Puz : 2933.85 Muz : 177.58 Muy : 273.26 IR: 0.97
STAAD SPACE -- PAGE NO. 22

============================================================================

============================================================================

C O L U M N N O. 13 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2100.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 8 SHORT COLUMN

REQD. STEEL AREA : 2374.54 Sq.mm.


REQD. CONCRETE AREA: 172625.47 Sq.mm.
MAIN REINFORCEMENT : Provide 12 - 16 dia. (1.38%, 2412.74 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2681.11 Muz1 : 150.10 Muy1 : 229.23

INTERACTION RATIO: 0.98 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 8 Puz : 2692.57 Muz : 151.07 Muy : 232.04 IR: 0.98
============================================================================

============================================================================

C O L U M N N O. 14 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 4050.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 26 SHORT COLUMN

STAAD SPACE -- PAGE NO. 23

REQD. STEEL AREA : 4153.24 Sq.mm.


REQD. CONCRETE AREA: 170846.75 Sq.mm.
MAIN REINFORCEMENT : Provide 24 - 16 dia. (2.76%, 4825.49 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 3214.72 Muz1 : 207.35 Muy1 : 322.39

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 26 Puz : 3416.40 Muz : 227.97 Muy : 355.35 IR: 0.91
============================================================================

============================================================================

C O L U M N N O. 16 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2100.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 30 END JOINT: 14 SHORT COLUMN

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 41 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

REQD. STEEL AREA : 2372.82 Sq.mm.


REQD. CONCRETE AREA: 172627.17 Sq.mm.
MAIN REINFORCEMENT : Provide 12 - 16 dia. (1.38%, 2412.74 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2680.60 Muz1 : 146.11 Muy1 : 221.92

INTERACTION RATIO: 0.99 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 12
END JOINT: 14 Puz : 2692.57 Muz : 148.10 Muy : 225.53 IR: 0.98
STAAD SPACE -- PAGE NO. 24

============================================================================

============================================================================

C O L U M N N O. 17 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2850.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 32 SHORT COLUMN

REQD. STEEL AREA : 4291.15 Sq.mm.


REQD. CONCRETE AREA: 170708.84 Sq.mm.
MAIN REINFORCEMENT : Provide 24 - 16 dia. (2.76%, 4825.49 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 3256.10 Muz1 : 210.45 Muy1 : 327.22

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 32 Puz : 3416.40 Muz : 226.91 Muy : 354.34 IR: 0.93
============================================================================

============================================================================

C O L U M N N O. 18 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 1200.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 68 SHORT COLUMN

STAAD SPACE -- PAGE NO. 25

REQD. STEEL AREA : 3458.16 Sq.mm.


REQD. CONCRETE AREA: 171541.84 Sq.mm.
MAIN REINFORCEMENT : Provide 12 - 20 dia. (2.15%, 3769.91 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 300 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 3006.20 Muz1 : 183.68 Muy1 : 282.78

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 68 Puz : 3099.72 Muz : 193.26 Muy : 300.60 IR: 0.94
============================================================================

============================================================================

C O L U M N N O. 19 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 42 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

LENGTH: 2100.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 30 END JOINT: 3 SHORT COLUMN

REQD. STEEL AREA : 2380.02 Sq.mm.


REQD. CONCRETE AREA: 172619.98 Sq.mm.
MAIN REINFORCEMENT : Provide 12 - 16 dia. (1.38%, 2412.74 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2682.76 Muz1 : 148.36 Muy1 : 225.33

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 12
END JOINT: 3 Puz : 2692.57 Muz : 150.35 Muy : 228.88 IR: 0.99
STAAD SPACE -- PAGE NO. 26

============================================================================

============================================================================

C O L U M N N O. 20 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2850.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 21 SHORT COLUMN

REQD. STEEL AREA : 3701.30 Sq.mm.


REQD. CONCRETE AREA: 171298.70 Sq.mm.
MAIN REINFORCEMENT : Provide 12 - 20 dia. (2.15%, 3769.91 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 300 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 3079.14 Muz1 : 193.30 Muy1 : 298.65

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 21 Puz : 3099.72 Muz : 194.52 Muy : 302.08 IR: 0.99
============================================================================

============================================================================

C O L U M N N O. 21 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 1200.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 30 END JOINT: 57 SHORT COLUMN

STAAD SPACE -- PAGE NO. 27

REQD. STEEL AREA : 2705.08 Sq.mm.


REQD. CONCRETE AREA: 172294.92 Sq.mm.
MAIN REINFORCEMENT : Provide 24 - 12 dia. (1.55%, 2714.34 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2780.27 Muz1 : 151.58 Muy1 : 231.15

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 57 Puz : 2783.05 Muz : 161.71 Muy : 246.75 IR: 0.99
============================================================================

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 43 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0
C O L U M N N O. 22 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2100.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 31 END JOINT: 9 SHORT COLUMN

REQD. STEEL AREA : 2124.60 Sq.mm.


REQD. CONCRETE AREA: 172875.41 Sq.mm.
MAIN REINFORCEMENT : Provide 20 - 12 dia. (1.29%, 2261.95 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2606.13 Muz1 : 142.09 Muy1 : 214.80

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 13
END JOINT: 9 Puz : 2647.33 Muz : 146.55 Muy : 222.03 IR: 0.97
STAAD SPACE -- PAGE NO. 28

============================================================================

============================================================================

C O L U M N N O. 23 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 4050.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 30 END JOINT: 27 SHORT COLUMN

REQD. STEEL AREA : 3676.27 Sq.mm.


REQD. CONCRETE AREA: 171323.73 Sq.mm.
MAIN REINFORCEMENT : Provide 12 - 20 dia. (2.15%, 3769.91 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 300 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 3071.63 Muz1 : 187.06 Muy1 : 288.86

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 12
END JOINT: 27 Puz : 3099.72 Muz : 190.94 Muy : 295.84 IR: 0.98
============================================================================

============================================================================

C O L U M N N O. 25 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2100.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 30 END JOINT: 15 SHORT COLUMN

STAAD SPACE -- PAGE NO. 29

REQD. STEEL AREA : 2285.23 Sq.mm.


REQD. CONCRETE AREA: 172714.78 Sq.mm.
MAIN REINFORCEMENT : Provide 12 - 16 dia. (1.38%, 2412.74 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2654.32 Muz1 : 141.78 Muy1 : 214.99

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 12
END JOINT: 15 Puz : 2692.57 Muz : 146.67 Muy : 223.38 IR: 0.96

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 44 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0
============================================================================

============================================================================

C O L U M N N O. 26 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2850.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 33 SHORT COLUMN

REQD. STEEL AREA : 4320.56 Sq.mm.


REQD. CONCRETE AREA: 170679.44 Sq.mm.
MAIN REINFORCEMENT : Provide 24 - 16 dia. (2.76%, 4825.49 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 3264.92 Muz1 : 210.85 Muy1 : 328.13

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 33 Puz : 3416.40 Muz : 226.57 Muy : 353.93 IR: 0.93
STAAD SPACE -- PAGE NO. 30

============================================================================

============================================================================

C O L U M N N O. 27 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 1200.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 69 SHORT COLUMN

REQD. STEEL AREA : 3090.75 Sq.mm.


REQD. CONCRETE AREA: 171909.25 Sq.mm.
MAIN REINFORCEMENT : Provide 16 - 16 dia. (1.84%, 3216.99 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2895.98 Muz1 : 171.20 Muy1 : 262.36

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 69 Puz : 2933.85 Muz : 175.21 Muy : 269.05 IR: 0.97
============================================================================

============================================================================

C O L U M N N O. 28 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2100.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 30 END JOINT: 4 SHORT COLUMN

STAAD SPACE -- PAGE NO. 31

REQD. STEEL AREA : 2498.89 Sq.mm.


REQD. CONCRETE AREA: 172501.11 Sq.mm.
MAIN REINFORCEMENT : Provide 8 - 20 dia. (1.44%, 2513.27 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 300 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2718.42 Muz1 : 151.80 Muy1 : 230.98

INTERACTION RATIO: 0.99 (as per Cl. 39.6, IS456:2000)

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 45 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0
SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)
----------------------------------------------------------
WORST LOAD CASE: 12
END JOINT: 4 Puz : 2722.73 Muz : 153.87 Muy : 235.55 IR: 0.98
============================================================================

============================================================================

C O L U M N N O. 29 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2850.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 22 SHORT COLUMN

REQD. STEEL AREA : 3859.63 Sq.mm.


REQD. CONCRETE AREA: 171140.36 Sq.mm.
MAIN REINFORCEMENT : Provide 8 - 25 dia. (2.24%, 3926.99 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 300 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 3126.64 Muz1 : 198.04 Muy1 : 306.47

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 22 Puz : 3146.85 Muz : 201.82 Muy : 314.63 IR: 0.98
STAAD SPACE -- PAGE NO. 32

============================================================================

============================================================================

C O L U M N N O. 30 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 1200.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 30 END JOINT: 58 SHORT COLUMN

REQD. STEEL AREA : 2856.74 Sq.mm.


REQD. CONCRETE AREA: 172143.27 Sq.mm.
MAIN REINFORCEMENT : Provide 16 - 16 dia. (1.84%, 3216.99 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2825.77 Muz1 : 156.50 Muy1 : 239.11

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 12
END JOINT: 58 Puz : 2933.85 Muz : 168.31 Muy : 258.86 IR: 0.93
============================================================================

============================================================================

C O L U M N N O. 31 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2100.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 31 END JOINT: 10 SHORT COLUMN

STAAD SPACE -- PAGE NO. 33

REQD. STEEL AREA : 2085.63 Sq.mm.


REQD. CONCRETE AREA: 172914.36 Sq.mm.
MAIN REINFORCEMENT : Provide 20 - 12 dia. (1.29%, 2261.95 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 46 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0
Puz : 2594.44 Muz1 : 141.21 Muy1 : 213.33

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 13
END JOINT: 10 Puz : 2647.33 Muz : 146.91 Muy : 222.60 IR: 0.96
============================================================================

============================================================================

C O L U M N N O. 32 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 4050.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 30 END JOINT: 28 SHORT COLUMN

REQD. STEEL AREA : 3687.15 Sq.mm.


REQD. CONCRETE AREA: 171312.84 Sq.mm.
MAIN REINFORCEMENT : Provide 12 - 20 dia. (2.15%, 3769.91 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 300 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 3074.89 Muz1 : 187.70 Muy1 : 289.83

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 12
END JOINT: 28 Puz : 3099.72 Muz : 191.21 Muy : 296.34 IR: 0.98
STAAD SPACE -- PAGE NO. 34

============================================================================

============================================================================

C O L U M N N O. 34 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2100.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 30 END JOINT: 16 SHORT COLUMN

REQD. STEEL AREA : 2176.02 Sq.mm.


REQD. CONCRETE AREA: 172823.98 Sq.mm.
MAIN REINFORCEMENT : Provide 20 - 12 dia. (1.29%, 2261.95 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2621.56 Muz1 : 138.48 Muy1 : 209.64

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 12
END JOINT: 16 Puz : 2647.33 Muz : 141.41 Muy : 214.40 IR: 0.98
============================================================================

============================================================================

C O L U M N N O. 35 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2850.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 34 SHORT COLUMN

STAAD SPACE -- PAGE NO. 35

REQD. STEEL AREA : 4304.69 Sq.mm.


REQD. CONCRETE AREA: 170695.31 Sq.mm.
MAIN REINFORCEMENT : Provide 24 - 16 dia. (2.76%, 4825.49 Sq.mm.)
(Equally distributed)

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 47 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 3260.16 Muz1 : 210.43 Muy1 : 327.41

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 34 Puz : 3416.40 Muz : 226.61 Muy : 353.98 IR: 0.93
============================================================================

============================================================================

C O L U M N N O. 36 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 1200.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 70 SHORT COLUMN

REQD. STEEL AREA : 2913.12 Sq.mm.


REQD. CONCRETE AREA: 172086.88 Sq.mm.
MAIN REINFORCEMENT : Provide 16 - 16 dia. (1.84%, 3216.99 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2842.69 Muz1 : 165.71 Muy1 : 253.38

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 70 Puz : 2933.85 Muz : 175.41 Muy : 269.34 IR: 0.94
STAAD SPACE -- PAGE NO. 36

============================================================================

============================================================================

C O L U M N N O. 46 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2100.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 31 END JOINT: 6 SHORT COLUMN

REQD. STEEL AREA : 2162.20 Sq.mm.


REQD. CONCRETE AREA: 172837.80 Sq.mm.
MAIN REINFORCEMENT : Provide 20 - 12 dia. (1.29%, 2261.95 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2617.41 Muz1 : 116.96 Muy1 : 177.58

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 13
END JOINT: 6 Puz : 2647.33 Muz : 120.89 Muy : 183.73 IR: 0.97
============================================================================

============================================================================

C O L U M N N O. 47 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2850.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 23 SHORT COLUMN

STAAD SPACE -- PAGE NO. 37

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 48 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

REQD. STEEL AREA : 2782.42 Sq.mm.


REQD. CONCRETE AREA: 172217.58 Sq.mm.
MAIN REINFORCEMENT : Provide 16 - 16 dia. (1.84%, 3216.99 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2803.48 Muz1 : 163.59 Muy1 : 249.87

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 23 Puz : 2933.85 Muz : 177.29 Muy : 272.57 IR: 0.92
============================================================================

============================================================================

C O L U M N N O. 48 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 1200.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 59 SHORT COLUMN

REQD. STEEL AREA : 2150.22 Sq.mm.


REQD. CONCRETE AREA: 172849.78 Sq.mm.
MAIN REINFORCEMENT : Provide 20 - 12 dia. (1.29%, 2261.95 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2613.82 Muz1 : 139.63 Muy1 : 211.38

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 59 Puz : 2647.33 Muz : 143.34 Muy : 217.43 IR: 0.97
STAAD SPACE -- PAGE NO. 38

============================================================================

============================================================================

C O L U M N N O. 49 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2100.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 30 END JOINT: 12 SHORT COLUMN

REQD. STEEL AREA : 2704.28 Sq.mm.


REQD. CONCRETE AREA: 172295.72 Sq.mm.
MAIN REINFORCEMENT : Provide 24 - 12 dia. (1.55%, 2714.34 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2780.03 Muz1 : 144.54 Muy1 : 220.56

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 12
END JOINT: 12 Puz : 2783.05 Muz : 145.16 Muy : 221.31 IR: 0.99
============================================================================

============================================================================

C O L U M N N O. 50 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 1575.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 49 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0
** GUIDING LOAD CASE: 30 END JOINT: 29 SHORT COLUMN

STAAD SPACE -- PAGE NO. 39

REQD. STEEL AREA : 4626.43 Sq.mm.


REQD. CONCRETE AREA: 170373.56 Sq.mm.
MAIN REINFORCEMENT : Provide 24 - 16 dia. (2.76%, 4825.49 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 3356.68 Muz1 : 211.07 Muy1 : 328.39

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 12
END JOINT: 29 Puz : 3416.40 Muz : 217.69 Muy : 338.93 IR: 0.97
============================================================================

============================================================================

C O L U M N N O. 51 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 1200.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 30 END JOINT: 65 SHORT COLUMN

REQD. STEEL AREA : 4419.12 Sq.mm.


REQD. CONCRETE AREA: 170580.88 Sq.mm.
MAIN REINFORCEMENT : Provide 24 - 16 dia. (2.76%, 4825.49 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 3294.49 Muz1 : 200.54 Muy1 : 311.31

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 12
END JOINT: 65 Puz : 3416.40 Muz : 214.34 Muy : 333.62 IR: 0.93
STAAD SPACE -- PAGE NO. 40

============================================================================

============================================================================

C O L U M N N O. 52 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2100.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 30 END JOINT: 18 SHORT COLUMN

REQD. STEEL AREA : 2989.02 Sq.mm.


REQD. CONCRETE AREA: 172010.98 Sq.mm.
MAIN REINFORCEMENT : Provide 16 - 16 dia. (1.84%, 3216.99 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2865.46 Muz1 : 146.86 Muy1 : 225.44

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 12
END JOINT: 18 Puz : 2933.85 Muz : 155.29 Muy : 238.97 IR: 0.94
============================================================================

============================================================================

C O L U M N N O. 53 D E S I G N R E S U L T S

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 50 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0
M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2850.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 30 END JOINT: 35 SHORT COLUMN

STAAD SPACE -- PAGE NO. 41

REQD. STEEL AREA : 4436.44 Sq.mm.


REQD. CONCRETE AREA: 170563.56 Sq.mm.
MAIN REINFORCEMENT : Provide 24 - 16 dia. (2.76%, 4825.49 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 3299.68 Muz1 : 201.19 Muy1 : 312.36

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 35 Puz : 3416.40 Muz : 223.58 Muy : 347.91 IR: 0.94
============================================================================

============================================================================

C O L U M N N O. 54 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 1200.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 71 SHORT COLUMN

REQD. STEEL AREA : 3750.13 Sq.mm.


REQD. CONCRETE AREA: 171249.88 Sq.mm.
MAIN REINFORCEMENT : Provide 12 - 20 dia. (2.15%, 3769.91 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 300 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 3093.79 Muz1 : 184.80 Muy1 : 285.14

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 71 Puz : 3099.72 Muz : 185.83 Muy : 287.90 IR: 0.99
STAAD SPACE -- PAGE NO. 42

============================================================================

============================================================================

C O L U M N N O. 176 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2800.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 30 END JOINT: 55 SHORT COLUMN

REQD. STEEL AREA : 1065.96 Sq.mm.


REQD. CONCRETE AREA: 133245.09 Sq.mm.
MAIN REINFORCEMENT : Provide 12 - 12 dia. (0.78%, 1357.17 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2288.54 Muz1 : 65.27 Muy1 : 97.40

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 12
END JOINT: 55 Puz : 2375.90 Muz : 78.40 Muy : 118.30 IR: 0.83
============================================================================

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 51 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0
C O L U M N N O. 177 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 1200.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 9 END JOINT: 102 SHORT COLUMN

STAAD SPACE -- PAGE NO. 43

REQD. STEEL AREA : 1062.53 Sq.mm.


REQD. CONCRETE AREA: 132816.70 Sq.mm.
MAIN REINFORCEMENT : Provide 12 - 12 dia. (0.78%, 1357.17 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2287.51 Muz1 : 72.13 Muy1 : 107.68

INTERACTION RATIO: 0.99 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 9
END JOINT: 102 Puz : 2375.90 Muz : 85.44 Muy : 128.99 IR: 0.84
============================================================================

============================================================================

C O L U M N N O. 178 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2800.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 31 END JOINT: 61 SHORT COLUMN

REQD. STEEL AREA : 1335.35 Sq.mm.


REQD. CONCRETE AREA: 166919.19 Sq.mm.
MAIN REINFORCEMENT : Provide 12 - 12 dia. (0.78%, 1357.17 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2369.36 Muz1 : 87.01 Muy1 : 130.51

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 13
END JOINT: 61 Puz : 2375.90 Muz : 88.74 Muy : 133.81 IR: 0.97
STAAD SPACE -- PAGE NO. 44

============================================================================

============================================================================

C O L U M N N O. 179 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 1200.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 29 END JOINT: 108 SHORT COLUMN

REQD. STEEL AREA : 1891.52 Sq.mm.


REQD. CONCRETE AREA: 173108.48 Sq.mm.
MAIN REINFORCEMENT : Provide 20 - 12 dia. (1.29%, 2261.95 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2536.20 Muz1 : 114.06 Muy1 : 172.20

INTERACTION RATIO: 0.99 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 11
END JOINT: 108 Puz : 2647.33 Muz : 127.86 Muy : 194.15 IR: 0.88

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 52 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0
============================================================================

============================================================================

C O L U M N N O. 180 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2800.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 30 END JOINT: 67 SHORT COLUMN

STAAD SPACE -- PAGE NO. 45

REQD. STEEL AREA : 1491.05 Sq.mm.


REQD. CONCRETE AREA: 173508.95 Sq.mm.
MAIN REINFORCEMENT : Provide 8 - 16 dia. (0.92%, 1608.50 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2416.06 Muz1 : 84.43 Muy1 : 127.39

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 12
END JOINT: 67 Puz : 2451.30 Muz : 90.33 Muy : 137.46 IR: 0.93
============================================================================

============================================================================

C O L U M N N O. 181 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 1200.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 29 END JOINT: 96 SHORT COLUMN

REQD. STEEL AREA : 2507.33 Sq.mm.


REQD. CONCRETE AREA: 172492.67 Sq.mm.
MAIN REINFORCEMENT : Provide 8 - 20 dia. (1.44%, 2513.27 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 300 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2720.95 Muz1 : 133.12 Muy1 : 203.03

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 11
END JOINT: 96 Puz : 2722.73 Muz : 137.31 Muy : 211.61 IR: 0.96
STAAD SPACE -- PAGE NO. 46

============================================================================

============================================================================

C O L U M N N O. 182 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2800.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 56 SHORT COLUMN

REQD. STEEL AREA : 2184.16 Sq.mm.


REQD. CONCRETE AREA: 172815.84 Sq.mm.
MAIN REINFORCEMENT : Provide 20 - 12 dia. (1.29%, 2261.95 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2624.00 Muz1 : 127.94 Muy1 : 193.89

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 53 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0
SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)
----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 56 Puz : 2647.33 Muz : 130.76 Muy : 198.38 IR: 0.98
============================================================================

============================================================================

C O L U M N N O. 183 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 1200.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 103 SHORT COLUMN

STAAD SPACE -- PAGE NO. 47

REQD. STEEL AREA : 1976.26 Sq.mm.


REQD. CONCRETE AREA: 173023.73 Sq.mm.
MAIN REINFORCEMENT : Provide 20 - 12 dia. (1.29%, 2261.95 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2561.63 Muz1 : 115.01 Muy1 : 173.92

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 103 Puz : 2647.33 Muz : 125.84 Muy : 191.20 IR: 0.91
============================================================================

============================================================================

C O L U M N N O. 184 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 4000.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 30 END JOINT: 109 SHORT COLUMN

REQD. STEEL AREA : 2536.33 Sq.mm.


REQD. CONCRETE AREA: 172463.67 Sq.mm.
MAIN REINFORCEMENT : Provide 24 - 12 dia. (1.55%, 2714.34 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2729.65 Muz1 : 134.39 Muy1 : 205.04

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 12
END JOINT: 109 Puz : 2783.05 Muz : 141.02 Muy : 215.06 IR: 0.95
STAAD SPACE -- PAGE NO. 48

============================================================================

============================================================================

C O L U M N N O. 185 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2800.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 68 SHORT COLUMN

REQD. STEEL AREA : 2789.96 Sq.mm.


REQD. CONCRETE AREA: 172210.05 Sq.mm.
MAIN REINFORCEMENT : Provide 16 - 16 dia. (1.84%, 3216.99 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 54 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0
Puz : 2805.74 Muz1 : 150.11 Muy1 : 229.15

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 68 Puz : 2933.85 Muz : 164.97 Muy : 254.04 IR: 0.91
============================================================================

============================================================================

C O L U M N N O. 186 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 1200.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 97 SHORT COLUMN

STAAD SPACE -- PAGE NO. 49

REQD. STEEL AREA : 2650.70 Sq.mm.


REQD. CONCRETE AREA: 172349.30 Sq.mm.
MAIN REINFORCEMENT : Provide 24 - 12 dia. (1.55%, 2714.34 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2763.96 Muz1 : 140.56 Muy1 : 214.48

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 97 Puz : 2783.05 Muz : 143.04 Muy : 218.08 IR: 0.98
============================================================================

============================================================================

C O L U M N N O. 187 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2800.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 57 SHORT COLUMN

REQD. STEEL AREA : 2180.83 Sq.mm.


REQD. CONCRETE AREA: 172819.17 Sq.mm.
MAIN REINFORCEMENT : Provide 20 - 12 dia. (1.29%, 2261.95 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2623.00 Muz1 : 127.47 Muy1 : 193.21

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 57 Puz : 2647.33 Muz : 130.44 Muy : 197.89 IR: 0.97
STAAD SPACE -- PAGE NO. 50

============================================================================

============================================================================

C O L U M N N O. 188 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 1200.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 104 SHORT COLUMN

REQD. STEEL AREA : 1798.04 Sq.mm.


REQD. CONCRETE AREA: 173201.95 Sq.mm.
MAIN REINFORCEMENT : Provide 16 - 12 dia. (1.03%, 1809.56 Sq.mm.)
(Equally distributed)

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 55 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2508.16 Muz1 : 107.51 Muy1 : 162.19

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 104 Puz : 2511.62 Muz : 107.79 Muy : 162.88 IR: 0.99
============================================================================

============================================================================

C O L U M N N O. 189 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 4000.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 30 END JOINT: 110 SHORT COLUMN

STAAD SPACE -- PAGE NO. 51

REQD. STEEL AREA : 2281.73 Sq.mm.


REQD. CONCRETE AREA: 172718.27 Sq.mm.
MAIN REINFORCEMENT : Provide 12 - 16 dia. (1.38%, 2412.74 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2653.27 Muz1 : 123.69 Muy1 : 187.94

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 12
END JOINT: 110 Puz : 2692.57 Muz : 128.75 Muy : 196.94 IR: 0.96
============================================================================

============================================================================

C O L U M N N O. 190 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2800.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 69 SHORT COLUMN

REQD. STEEL AREA : 2782.54 Sq.mm.


REQD. CONCRETE AREA: 172217.47 Sq.mm.
MAIN REINFORCEMENT : Provide 16 - 16 dia. (1.84%, 3216.99 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2803.51 Muz1 : 149.03 Muy1 : 227.50

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 69 Puz : 2933.85 Muz : 164.32 Muy : 253.05 IR: 0.90
STAAD SPACE -- PAGE NO. 52

============================================================================

============================================================================

C O L U M N N O. 191 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 1200.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 98 SHORT COLUMN

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 56 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0
REQD. STEEL AREA : 2099.82 Sq.mm.
REQD. CONCRETE AREA: 172900.19 Sq.mm.
MAIN REINFORCEMENT : Provide 20 - 12 dia. (1.29%, 2261.95 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2598.69 Muz1 : 119.14 Muy1 : 180.56

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 98 Puz : 2647.33 Muz : 125.29 Muy : 190.32 IR: 0.95
============================================================================

============================================================================

C O L U M N N O. 192 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2800.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 58 SHORT COLUMN

STAAD SPACE -- PAGE NO. 53

REQD. STEEL AREA : 2254.84 Sq.mm.


REQD. CONCRETE AREA: 172745.16 Sq.mm.
MAIN REINFORCEMENT : Provide 20 - 12 dia. (1.29%, 2261.95 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2645.20 Muz1 : 130.19 Muy1 : 197.50

INTERACTION RATIO: 0.99 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 58 Puz : 2647.33 Muz : 130.45 Muy : 197.91 IR: 0.99
============================================================================

============================================================================

C O L U M N N O. 193 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 1200.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 105 SHORT COLUMN

REQD. STEEL AREA : 1740.61 Sq.mm.


REQD. CONCRETE AREA: 173259.39 Sq.mm.
MAIN REINFORCEMENT : Provide 16 - 12 dia. (1.03%, 1809.56 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2490.93 Muz1 : 105.33 Muy1 : 158.76

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 105 Puz : 2511.62 Muz : 107.89 Muy : 163.02 IR: 0.97
STAAD SPACE -- PAGE NO. 54

============================================================================

============================================================================

C O L U M N N O. 194 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 4000.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 57 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

** GUIDING LOAD CASE: 30 END JOINT: 111 SHORT COLUMN

REQD. STEEL AREA : 2287.80 Sq.mm.


REQD. CONCRETE AREA: 172712.20 Sq.mm.
MAIN REINFORCEMENT : Provide 12 - 16 dia. (1.38%, 2412.74 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2655.09 Muz1 : 124.15 Muy1 : 188.67

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 12
END JOINT: 111 Puz : 2692.57 Muz : 128.96 Muy : 197.25 IR: 0.96
============================================================================

============================================================================

C O L U M N N O. 195 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2800.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 70 SHORT COLUMN

STAAD SPACE -- PAGE NO. 55

REQD. STEEL AREA : 2779.20 Sq.mm.


REQD. CONCRETE AREA: 172220.80 Sq.mm.
MAIN REINFORCEMENT : Provide 16 - 16 dia. (1.84%, 3216.99 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2802.51 Muz1 : 148.89 Muy1 : 227.28

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 70 Puz : 2933.85 Muz : 164.31 Muy : 253.00 IR: 0.90
============================================================================

============================================================================

C O L U M N N O. 196 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 1200.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 99 SHORT COLUMN

REQD. STEEL AREA : 2093.50 Sq.mm.


REQD. CONCRETE AREA: 172906.50 Sq.mm.
MAIN REINFORCEMENT : Provide 20 - 12 dia. (1.29%, 2261.95 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2596.80 Muz1 : 119.05 Muy1 : 180.40

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 99 Puz : 2647.33 Muz : 125.42 Muy : 190.53 IR: 0.95
STAAD SPACE -- PAGE NO. 56

============================================================================

C O L U M N N O. 202 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 58 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

LENGTH: 2800.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 59 SHORT COLUMN

REQD. STEEL AREA : 1851.53 Sq.mm.


REQD. CONCRETE AREA: 173148.47 Sq.mm.
MAIN REINFORCEMENT : Provide 20 - 12 dia. (1.29%, 2261.95 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2524.21 Muz1 : 112.60 Muy1 : 169.89

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 59 Puz : 2647.33 Muz : 127.92 Muy : 194.23 IR: 0.88
============================================================================

============================================================================

C O L U M N N O. 203 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 1200.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 106 SHORT COLUMN

STAAD SPACE -- PAGE NO. 57

REQD. STEEL AREA : 1941.20 Sq.mm.


REQD. CONCRETE AREA: 173058.80 Sq.mm.
MAIN REINFORCEMENT : Provide 20 - 12 dia. (1.29%, 2261.95 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2551.11 Muz1 : 108.38 Muy1 : 164.19

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 106 Puz : 2647.33 Muz : 121.13 Muy : 184.08 IR: 0.89
============================================================================

============================================================================

C O L U M N N O. 204 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 1525.5 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 30 END JOINT: 65 SHORT COLUMN

REQD. STEEL AREA : 2866.85 Sq.mm.


REQD. CONCRETE AREA: 172133.14 Sq.mm.
MAIN REINFORCEMENT : Provide 16 - 16 dia. (1.84%, 3216.99 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2828.81 Muz1 : 144.64 Muy1 : 221.60

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 12
END JOINT: 65 Puz : 2933.85 Muz : 157.62 Muy : 242.42 IR: 0.92
STAAD SPACE -- PAGE NO. 58

============================================================================

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 59 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0
C O L U M N N O. 205 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 1200.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 112 SHORT COLUMN

REQD. STEEL AREA : 2823.83 Sq.mm.


REQD. CONCRETE AREA: 172176.17 Sq.mm.
MAIN REINFORCEMENT : Provide 16 - 16 dia. (1.84%, 3216.99 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2815.90 Muz1 : 145.59 Muy1 : 222.66

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 112 Puz : 2933.85 Muz : 160.14 Muy : 246.08 IR: 0.91
============================================================================

============================================================================

C O L U M N N O. 206 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2800.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 71 SHORT COLUMN

STAAD SPACE -- PAGE NO. 59

REQD. STEEL AREA : 2995.84 Sq.mm.


REQD. CONCRETE AREA: 172004.16 Sq.mm.
MAIN REINFORCEMENT : Provide 16 - 16 dia. (1.84%, 3216.99 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2867.50 Muz1 : 155.41 Muy1 : 237.87

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 71 Puz : 2933.85 Muz : 163.46 Muy : 251.49 IR: 0.95
============================================================================

============================================================================

C O L U M N N O. 207 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 1200.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 100 SHORT COLUMN

REQD. STEEL AREA : 2309.97 Sq.mm.


REQD. CONCRETE AREA: 172690.03 Sq.mm.
MAIN REINFORCEMENT : Provide 12 - 16 dia. (1.38%, 2412.74 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2661.74 Muz1 : 124.18 Muy1 : 188.76

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 100 Puz : 2692.57 Muz : 128.20 Muy : 196.17 IR: 0.97
STAAD SPACE -- PAGE NO. 60

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 60 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0
============================================================================

============================================================================

C O L U M N N O. 254 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2100.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 31 END JOINT: 135 SHORT COLUMN

REQD. STEEL AREA : 1814.12 Sq.mm.


REQD. CONCRETE AREA: 173185.88 Sq.mm.
MAIN REINFORCEMENT : Provide 20 - 12 dia. (1.29%, 2261.95 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2512.99 Muz1 : 99.01 Muy1 : 150.07

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 13
END JOINT: 135 Puz : 2647.33 Muz : 117.21 Muy : 178.51 IR: 0.84
============================================================================

============================================================================

C O L U M N N O. 255 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 1525.5 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 137 SHORT COLUMN

STAAD SPACE -- PAGE NO. 61

REQD. STEEL AREA : 1543.12 Sq.mm.


REQD. CONCRETE AREA: 173456.88 Sq.mm.
MAIN REINFORCEMENT : Provide 8 - 16 dia. (0.92%, 1608.50 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 255 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2431.69 Muz1 : 108.66 Muy1 : 162.85

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 137 Puz : 2451.30 Muz : 114.32 Muy : 172.93 IR: 0.94
============================================================================

============================================================================

C O L U M N N O. 256 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2100.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 30 END JOINT: 136 SHORT COLUMN

REQD. STEEL AREA : 1782.49 Sq.mm.


REQD. CONCRETE AREA: 173217.50 Sq.mm.
MAIN REINFORCEMENT : Provide 16 - 12 dia. (1.03%, 1809.56 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2503.50 Muz1 : 134.74 Muy1 : 202.71

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 61 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0
WORST LOAD CASE: 12
END JOINT: 136 Puz : 2511.62 Muz : 135.66 Muy : 204.46 IR: 0.99
STAAD SPACE -- PAGE NO. 62

============================================================================

============================================================================

C O L U M N N O. 257 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 4000.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 139 SHORT COLUMN

REQD. STEEL AREA : 1649.15 Sq.mm.


REQD. CONCRETE AREA: 173350.84 Sq.mm.
MAIN REINFORCEMENT : Provide 16 - 12 dia. (1.03%, 1809.56 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2463.49 Muz1 : 107.94 Muy1 : 162.22

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 139 Puz : 2511.62 Muz : 114.05 Muy : 172.00 IR: 0.95
============================================================================

============================================================================

C O L U M N N O. 264 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 4050.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 138 SHORT COLUMN

STAAD SPACE -- PAGE NO. 63

REQD. STEEL AREA : 2690.63 Sq.mm.


REQD. CONCRETE AREA: 172309.38 Sq.mm.
MAIN REINFORCEMENT : Provide 24 - 12 dia. (1.55%, 2714.34 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2775.94 Muz1 : 160.42 Muy1 : 244.64

INTERACTION RATIO: 0.99 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 138 Puz : 2783.05 Muz : 161.49 Muy : 246.30 IR: 0.99
============================================================================

============================================================================

C O L U M N N O. 266 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 1575.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 142 SHORT COLUMN

REQD. STEEL AREA : 3378.33 Sq.mm.


REQD. CONCRETE AREA: 171621.67 Sq.mm.
MAIN REINFORCEMENT : Provide 12 - 20 dia. (2.15%, 3769.91 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 300 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2982.25 Muz1 : 184.08 Muy1 : 283.42

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 62 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0
INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 142 Puz : 3099.72 Muz : 194.94 Muy : 302.42 IR: 0.94
STAAD SPACE -- PAGE NO. 64

============================================================================

============================================================================

C O L U M N N O. 275 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 1275.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 30 END JOINT: 48 SHORT COLUMN

REQD. STEEL AREA : 1250.32 Sq.mm.


REQD. CONCRETE AREA: 156290.56 Sq.mm.
MAIN REINFORCEMENT : Provide 12 - 12 dia. (0.78%, 1357.17 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2343.85 Muz1 : 87.02 Muy1 : 130.10

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 12
END JOINT: 48 Puz : 2375.90 Muz : 92.14 Muy : 138.65 IR: 0.94
============================================================================

============================================================================

C O L U M N N O. 276 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2475.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 137 SHORT COLUMN

STAAD SPACE -- PAGE NO. 65

REQD. STEEL AREA : 3238.33 Sq.mm.


REQD. CONCRETE AREA: 171761.67 Sq.mm.
MAIN REINFORCEMENT : Provide 12 - 20 dia. (2.15%, 3769.91 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 300 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2940.25 Muz1 : 178.48 Muy1 : 274.58

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 137 Puz : 3099.72 Muz : 194.15 Muy : 301.79 IR: 0.92
============================================================================

============================================================================

C O L U M N N O. 278 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 1274.5 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 31 END JOINT: 88 SHORT COLUMN

REQD. STEEL AREA : 1231.81 Sq.mm.


REQD. CONCRETE AREA: 153976.67 Sq.mm.
MAIN REINFORCEMENT : Provide 12 - 12 dia. (0.78%, 1357.17 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 63 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0
SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)
----------------------------------------------------------
Puz : 2338.29 Muz1 : 82.07 Muy1 : 122.92

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 13
END JOINT: 88 Puz : 2375.90 Muz : 88.14 Muy : 132.96 IR: 0.92
STAAD SPACE -- PAGE NO. 66

============================================================================

============================================================================

C O L U M N N O. 279 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 2474.5 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 140 SHORT COLUMN

REQD. STEEL AREA : 2013.59 Sq.mm.


REQD. CONCRETE AREA: 172986.41 Sq.mm.
MAIN REINFORCEMENT : Provide 20 - 12 dia. (1.29%, 2261.95 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2572.83 Muz1 : 120.20 Muy1 : 181.83

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 140 Puz : 2647.33 Muz : 129.33 Muy : 196.27 IR: 0.93
============================================================================

============================================================================

C O L U M N N O. 284 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 3000.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 156 SHORT COLUMN

STAAD SPACE -- PAGE NO. 67

REQD. STEEL AREA : 743.17 Sq.mm.


REQD. CONCRETE AREA: 92896.77 Sq.mm.
MAIN REINFORCEMENT : Provide 8 - 12 dia. (0.52%, 904.78 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2191.70 Muz1 : 49.63 Muy1 : 73.19

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 156 Puz : 2240.18 Muz : 56.93 Muy : 84.79 IR: 0.87
============================================================================

============================================================================

C O L U M N N O. 285 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 3000.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 154 SHORT COLUMN

REQD. STEEL AREA : 964.25 Sq.mm.


REQD. CONCRETE AREA: 120531.60 Sq.mm.

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 64 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0
MAIN REINFORCEMENT : Provide 12 - 12 dia. (0.78%, 1357.17 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2258.03 Muz1 : 52.59 Muy1 : 77.97

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 154 Puz : 2375.90 Muz : 70.60 Muy : 106.17 IR: 0.74
STAAD SPACE -- PAGE NO. 68

============================================================================

============================================================================

C O L U M N N O. 286 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 3000.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 153 SHORT COLUMN

REQD. STEEL AREA : 911.75 Sq.mm.


REQD. CONCRETE AREA: 113969.01 Sq.mm.
MAIN REINFORCEMENT : Provide 12 - 12 dia. (0.78%, 1357.17 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2242.28 Muz1 : 49.85 Muy1 : 73.76

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 153 Puz : 2375.90 Muz : 70.35 Muy : 105.79 IR: 0.71
============================================================================

============================================================================

C O L U M N N O. 287 D E S I G N R E S U L T S

M25 Fe415 (Main) Fe415 (Sec.)

LENGTH: 3000.0 mm CROSS SECTION: 500.0 mm X 350.0 mm COVER: 40.0 mm

** GUIDING LOAD CASE: 28 END JOINT: 155 SHORT COLUMN

STAAD SPACE -- PAGE NO. 69

REQD. STEEL AREA : 811.03 Sq.mm.


REQD. CONCRETE AREA: 101378.58 Sq.mm.
MAIN REINFORCEMENT : Provide 8 - 12 dia. (0.52%, 904.78 Sq.mm.)
(Equally distributed)
TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c

SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET)


----------------------------------------------------------
Puz : 2212.06 Muz1 : 52.95 Muy1 : 78.30

INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000)

SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS-MET)


----------------------------------------------------------
WORST LOAD CASE: 10
END JOINT: 155 Puz : 2240.18 Muz : 57.07 Muy : 85.01 IR: 0.92
============================================================================

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 65 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

4.0 DESIGN CALCULATION

4.10 SLAB DESIGN

2.135 2.865 5.00 m 5.00 m 5.00 m

2.50 m S1 S2 S2 S1

2.50 m S3 S4 S4 S3

S5a
3.00 m S5 S6 S6 S7

2.00 m S8 S9 S9 S8

SLAB NUMBERING AND LAYOUT - EL (+) 104 M (TOC)

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 66 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

4.1.1 MODEL CALCULATION FOR TWO WAY SLAB

SLAB-S1
Sample calculation
Input:
Thickness of slab, Thk = 150 mm
Clear cover = 20 mm
Top Reinforcement:
Assumed Dia of Main bar = 8 mm
Assumed Dia of secondary bar = 8 mm
Effective length in shorter-direction, Eff Lx = 2.50 m
Effective length in Longer direction, Eff Ly = 5.00 m
2
Dead load 3.75 kN/m
2
Finished load, FL = 0.00 kN/m
2
Live load, LL = 7.50 kN/m
3
Unit weight of concrete = 25.00 kN/m
2
Grade of concrete,fck = 25.00 N/mm
2
Grade of steel,fy = 415.00 N/mm
Factor of Saftey = 1.50

2
Total Factor Load = 16.88 kN/m

Analysis :
Consider One meter breadth of the slab.
coefficient calculations for Moments :
Ratio of eff.Ly/ eff.Lx,r = 2.00 < 2 Therefore Slab is Designed as two way
Condition = = Two Adjacent end Discontinuous
shorter side of edge1,α x - = 0.0910 (IS 456-2000 -Annexure-D-Table-26)
shorterside of edge2,α x + = 0.0690
longer side of edge1,α y- = 0.0470
longer side of edge2,α y+ = 0.0350

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 67 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

Select sides of the slab :


DL+LL+FL

discontinuous continuous
2.50 m in lx-direction

DL + LL+FL

discontinuous continuous

5.00 m in ly-direction
cl2

discontinuous

cs1 cs2
y
discontinuous 2.50 continuous
x

5.00

continuous
cl1

- 2
Dead load '-ve' beinding moment, Mx- = αx x w x Lx
= 9.60 kN m
- 2
Dead load '-ve'beinding moment, MY- = αy x w x Lx
= 4.96 kN m
+ 2
Dead load '+ve' beinding moment, Mx+ = αx x w x Lx
= 7.28 kN m
+ 2
Dead load '+ve' beinding moment, MY+ = αy x w x Lx
= 3.69 kN m
Dead load Shear force in X-dir Vu = w x lx /2
= 21.09 kN
Dead load Shear force in Y-dir Vu = w x ly /2
= 42.19 kN

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 68 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

Check for Slab Thickness


Assume dia of bar = 8 mm
Effective Thickness of the Slab = 150 - 20 - 8-8 / 2
for shorter direction = 118 mm
Effective depth required for Slab = v(Mux/(0.138 x fck x 1000))
d-reqd = 52.74 mm
Provided depth is ok
Calculation of main steel

Effective Depth of slab in X dir dx = 126.000 mm


(150-20-8/2)
Effective Depth of slab in Y dir dy = 118.000 mm
(150-20-8-8/2)

2
(a) Area of Steel Mx- = ( 0.5 fck/fy ) x [ 1-v( 1 - (4.6Mu/(fck x 1000 x d )) ) ] x 1000d
AstR = 217.30 mm2 / mm

Required spacing of steel S = 231.20 mm

2
(b) Area of Steel MY- = ( 0.5 fck/fy ) x [ 1-v( 1 - (4.6Mu/(fck x 1000 x d )) ) ] x 1000d
AstR = 175.22 mm2 / mm

Required spacing of steel S = 286.73 mm2 / mm

2
(c) Area of Steel Mx+ = ( 0.5 fck/fy ) x [ 1-v( 1 - (4.6Mu/(fck x 1000 x d )) ) ] x 1000d
AstR = 163.57 mm2 / mm

Required spacing of steel S 307.14 mm

2
(c) Area of Steel My+ AstR = ( 0.5 fck/fy ) x [ 1-v( 1 - (4.6Mu/(fck x 1000 x d )) ) ] x 1000d
= 87.77 mm2 / mm

Required spacing of steel S = 572.39 mm

Minimum percentage of steel is = 0.12


Minimun area of the steel = 0.12 % x b x D
= 0.12x 1000 x 150/ 100
AstM = 180 mm2 / mm
Higher value of Ast is provided, AstP = 250.00 mm2 / mm
provide 8 mm dia bar at 200 mm c/c on positive and negative reinforcement
Maximum allowable spacing = 3d or 300 mm whichever is lesser Cls 26.3
Spacing is less than maximum spacing, OK
Provide8 mm Dia bar @ 200 mm c/c as main steel

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 69 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

Shear Check

Check for shear in X-direction:


Designed Shear Force = k τc bd , k and τc are calculated below (IS 456-2000-Table -23)

Percentage of Steel Provided Pt = 100xAst/bxd

= 0.21186441
k = 1.300 Refer Cls 40.2

τc = 0.332 N/mm2 (Refer IS 456-2000-Table 19)

Vult = 50.93 KN
Depth k
300 1.00
275 1.05
Vu = 42.19 KN 175 1.25
150 1.30

Vult > Vu Therefore No shear reinforcement is required

Check for Deflection


(Refer RCC Design by Unnikrishnapillai and devodos menon)

Basic span depth ratio for S.S slab = 26 (From IS 456-2000 Clause :23.2.1.a)
fs = 0.58 x fy x Ast required / Ast provided
= 240.7 (Ast provided = Ast required)

Effective Span length = 1.87

Percentage of Steel Provided Pt = 0.212

Modification Factor kt = 1.7 (From IS 456-2000-Fig-4 )

(l/d)max = 44.2
(26x1.7)

(l/d)provided = 15.85
(1.87 X 1000)/118

(l/d)provided < (l/d)max Hence it is Safe.

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 70 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

4.1.2 MODEL CALCULATION FOR ONEWAY SLAB


Sample calculation
Input:
Slab No:S16
Thickness of slab, Thk = 150 mm
Clear cover = 20 mm
Main Dia of bar, main dia = 8 mm
Secondary dia of bar, sec dia = 8 mm
Effective length, Eff Lx = 2 m DL + LL+FL
2
Finished load, F.L = 0.00 kN/m
2
Live load, L.L = 7.50 kN/m
3
Unit weight of concrete = 25 kN/m 2
2
Grade of concrete, fck = 25 N\mm
2
Grade of steel, fy = 415 N\mm

Analysis :
Consider One meter breadth of the slab.
Both sides of the slab are simply supported
Dead load of slab+ Finishes, w = 3.75 kN/m2
2
beinding moment, B.M(dead load) = wlx /8
= 3.75 x 2 x 2 / 8
= 1.88 kN m
bending moment, B.M(live load) = 7.5 x 2 x 2 / 8
= 3.75 kN m
Shear force, S.F(dead load) = 3.75 x 2 / 2
= 3.75 kN
Shear force, S.F(live load) = 7.5 x 2 / 2
= 7.50 kN
Design :
The design of slab is done as per IS 456:2000
For dead load + live load combination partial safety factor 1.5 is used (Refer Cls 36.4)
Factored bending moment, Mu = 1.9 x 1.5 + 3.75 x 1.5
= 8.44 kN m
Factored shear force, Vu = 3.8 x 1.5 + 7.50 x 1.5
= 16.875 kN
Check for Slab Thickness
Effective Thickness of the Slab, = 150 - 20 - 8 / 2
Thk = 126 mm
Effective depth required for Slab, = v(Mu/(0.138 x fck x 1000)) (Ref. Shah & karve)
= v [8.44x 1000 x 1000 / ( 0.138 x 25.00 x 1000 )]
d reqd = 49.45 mm
Provided depth is ok

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 71 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

Calculation of main steel


2
Area of Steel = ( 0.5 fck/fy ) x [ 1-v( 1 - (4.6Mu/(fck x 1000 x d )) ) ] x 1000d
= 0.5 x 25/415 x [ 1-v( 1 - (4.6 x 8.44/(25x 1000 x126x126)) ) ]
= x 1000 x 126
2
AstR = 190.337 mm
Minimum percentage of steel is = 0.12

Minimun area of the steel = 0.12 % x b x D


= 0.12x 1000 x 150/ 100
AstM = 180 mm2
2
Area of steel required AstP = 190.337 mm
Spacing of main steel = 264 mm Say 200 mm c/c
Maximum allowable spacing = 3d or 300 mm whichever is lesser Cls 26.3
Spacing is less than maximum spacing

Provide8 mm Dia bar @ 200 mm c/c as main steel


Provide distribution steel 0.12 % b x D
= 0.12x 1000 x 150/ 100
AstP = 180 mm2
Spacing of dist.steel = 279 mm
Max. allowable spacing of Dist.steel = 5d or 450 mm whichever is lesser Cls 26.3
Spacing required = 279 mm Say 200 mm c/c
Spacing is less than maximum spacing
Provide8 mm Dia bar @ 200 mm c/c as distribution steel
Check for shear

Design Shear Force = k τc bd , k and τc are calculated below


= 1.3 x 0.29 x 1000 x 126 Depth k
Vult = 47.50 KN 300 1.00
Ultimate shear force > Actual shear force , hence ok 275 1.05
k = 1.300 Refer Cls 40.2 175 1.25
150 1.30

2
τc = 0.29 N/mm Refer IS 456-2000 Table 19

Actual area of main steel provided = (π x 8 x 8/ 4)x 1000/200


= 190.4 mm2

Percentage of steel provided, pt = 100 x Astp / bd


= 0.151

Check for Deflection of the slab


Basic span depth ratio for simple supported sla 0.58 x fy x Ast required / Ast provided
fs = 240.7 (assumed Ast provided = Ast required)
= 1/(0.225+0.00322xfs + 0.625xlog 10(pt)
α1 = 1.70
= α1 x 20
Allowable span depth ratio = 1.7 x 20
= 24.4704
= 2 x 1000 / 180
Assumed span depth ratio = 11.11

Assumed Span Depth ratio < Allowable span depth ratio

Hence the design is OK.

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 72 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

SUMMARY OF SLAB CALCULATION


SUMMARY OF CALCULATIONS

Design Coefficients -IS 456-2000 Annexure D-Table 26

Slab No (ly/lx) ax- ax+ ay- ay+ Remarks


S1 2 0.091 0.069 0.047 0.035 Two way slab
S2 2 0.085 0.065 0.037 0.028 Two way slab
S3 2 0.068 0.052 0.037 0.028 Two way slab
S4 2 0.065 0.049 0.032 0.024 Two way slab
S5 1.4 0.063 0.047 0.037 0.028 Two way slab
S5a 1.047 0.0343 0.0258 0.032 0.024 Two way slab
S6 1.67 0.057 0.0477 0.032 0.024 Two way slab
S7 1.67 0.0617 0.0467 0.037 0.028 Two way slab
S8 2.5 - - - - One way slab
S9 2.5 - - - - One way slab

INPUT VALUES
Slab Thk Cover Eff Lx Eff Ly F.L L.L fY fck
No mm mm m m kN/m2 kN/m2 N/mm 2
N/mm2
S1 150 20 2.50 5 0 7.5 415 25
S2 150 20 2.50 5 0 7.5 415 25
S3 150 20 2.50 5 0 7.5 415 25
S4 150 20 2.50 5 0 7.5 415 25
S5 150 20 2.14 3 0 7.5 415 25
S5a 150 20 2.87 3 0 7.5 415 25
S6 150 20 3.00 5 0 7.5 415 25
S7 150 20 3.00 5 0 7.5 415 25
S8 150 20 2 5 0 7.5 415 25
S9 150 20 2 5 0 7.5 415 25

TOP REINFORCEMENT DETAILS


Main Spacing Secondary Spacing
Slab No Ast (req) Ast (Provided) Ast (req) Ast (Provided)
mm mm mm mm
S1 8 200 217.3 250 8 200 175.2 250
S2 8 200 202.57 250 8 200 164.81 250
S3 8 200 161.5 250 8 200 131.22 250
S4 8 200 153.89 250 8 200 123.51 250
S5 8 200 108.12 250 8 200 85.94 250
S5a 8 200 105.97 250 8 200 84.94
S6 8 200 212.44 250 8 200 159.44 250
S7 8 200 212.01 250 8 200 170.66 250
S8 8 200 180 250 8 200 180 250
S9 8 200 180 250 8 200 180 250

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 73 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

BOTTOM REINFORCEMENT DETAILS


Main Spacing Ast(Provided) Secondary Spacing Ast(Req) Ast(Provided)
Slab No Ast (req)
mm mm mm2/mm mm mm mm2/mm mm2/mm
S1 8 200 163.57 250 8 200 87.77 250
S2 8 200 153.89 250 8 200 70.04 250
S3 8 200 122.6 250 8 200 70.04 250
S4 8 200 115.41 250 8 200 59.95 250
S5 8 200 80.36 250 8 200 50.94 250
S5a 8 200 79.43 250 8 200 78.94 250
S6 8 200 148.88 250 8 200 86.65 250
S7 8 200 159.33 250 8 200 86.65 250
S8 10 200 190.34 250 8 200 180 250
S9 10 200 190.34 250 8 200 180 250
4.20 DESIGN OF BEAM

4.2.1 PLINTH BEAM


PB1 300X500
INPUT SECTION MOMENT DESIGN

req
Effective
Mu b D d 2
fck fy Pt Ptmini Check for tension
SL NO cover Mu/bd Mulimit/bd2 reinforceme
Remarks
KN-m mm mm mm N/mm2 N/mm2 % % pt
mm
nt mm2

1 210.00 50 300 500 450 3.46 25 415 3.45 1.20 0.20 OK 1616.03 Top
2 130.00 50 300 500 450 2.14 25 415 3.45 0.67 0.20 OK 899.7 Bottom
SHEAR DESIGN
Ast Pt
Vu at provided provided Stirrup Spacing Mini Spacing
SL NO support at at τc τv τc max Check
Dia
Shear legs
Of stirrup Spacing
0.75*d
300 mm Provided
KN support support N/mm
2
N/mm 2
N/mm 2 for τc mm
(Nos)
mm mm
mm
mm
2 2
mm mm
1 136 1721 1.27 0.70 1.01 3.1 O.K 8 2 300.00 -- 338.00 300 300.00

PB2 300X500
INPUT SECTION MOMENT DESIGN

req
Effective
Mu b D d 2
fck fy Pt Ptmini Check for tension
SL NO cover Mu/bd Mulimit/bd2 reinforceme
Remarks
KN-m mm mm mm N/mm2 N/mm2 % % pt
mm
nt mm2

1 202.00 50 300 500 450 3.33 25 415 3.45 1.14 0.20 OK 1534.76 Top Rein
2 134.00 50 300 500 450 2.21 25 415 3.45 0.69 0.20 OK 933.5 Bottom rein
SHEAR DESIGN
Ast Pt
Vu at provided provided Stirrup Spacing Mini Spacing
SL NO support at at τc τv τc max Check
Dia
Shear legs
Of stirrup Spacing
0.75*d
300 mm Provided
KN support support N/mm
2
N/mm2 N/mm2 for τc mm
(Nos)
mm mm
mm
mm
mm2 mm2
1 116 1721 1.27 0.70 0.86 3.1 O.K 8 2 300.00 -- 338.00 300 300.00

PB3 300X500
INPUT SECTION MOMENT DESIGN
req
Effective tension
Mu b D d fck fy Pt Ptmini Check for
SL NO cover Mu/bd2 Mulimit/bd2 reinforce
KN-m mm mm mm N/mm2 N/mm2 % % pt
ment
mm
mm2 Remarks
1 80.26 50 300 500 450 1.33 25 415 3.45 0.39 0.20 OK 532.12 bottom
2
SHEAR DESIGN
Ast Pt
Vu at provided provided Stirrup Spacing Mini Spacing
SL NO support at at τc τv τc max Check
Dia
Shear legs
Of stirrup Spacing
0.75*d 300
Provided
KN support support N/mm
2
N/mm2 N/mm2 for τc mm
(Nos)
mm mm
mm mm
mm
mm2 mm2
1 64.4 603 0.45 0.47 0.48 3.1 O.K 8 2 300.00 -- 338.00 300 300.00

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 74 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

PB4 300X500
INPUT SECTION MOMENT DESIGN

req
Effective
Mu b D d fck fy Pt Ptmini Check for tension
SL NO cover Mu/bd2 Mulimit/bd2 reinforceme
Remarks
KN-m mm mm mm N/mm2 N/mm2 % % pt
mm
nt mm2

1 151.00 50 300 500 450 2.49 25 415 3.45 0.79 0.20 OK 1072.47 Top Rein
2 154.00 50 300 500 450 2.54 25 415 3.45 0.81 0.20 OK 1097.97 Bottom Rein
SHEAR DESIGN
Ast Pt
Vu at provided provided Stirrup Spacing Mini Spacing
SL NO support at at τc τv τc max Check
Dia
Shear legs
Of stirrup Spacing
0.75*d
300 mm Provided
KN support support N/mm
2
N/mm 2
N/mm 2 for τc mm
(Nos)
mm mm
mm
mm
mm2 mm2
1 74 1294 0.96 0.63 0.55 3.1 O.K 8 2 -- 302.32 338.00 300 300.00

PB4a 230X500
INPUT SECTION MOMENT DESIGN
req
Effective tension
Mu b D d fck fy Pt Ptmini Check for
SL NO cover Mu/bd2 Mulimit/bd2 reinforce
KN-m mm mm mm N/mm2 N/mm2 % % pt
ment
mm
mm2 Remarks
1 20.06 50 230 500 450 0.44 25 415 3.45 0.12 0.20 Astmini 128.8 Bottom

SHEAR DESIGN
Ast Pt
Vu at provided provided Stirrup Spacing Mini Spacing
SL NO support at at τc τv τc max Check
Dia
Shear legs
Of stirrup Spacing
0.75*d 300
Provided
KN support support N/mm
2
N/mm 2
N/mm 2 for τc mm
(Nos)
mm mm
mm mm
mm
2 2
mm mm
1 25.64 402 0.39 0.44 0.25 3.1 O.K 8 2 -- 394.33 338.00 300 300.00

PB5 300X500
INPUT SECTION MOMENT DESIGN

req
Effective
Mu b D d 2
fck fy Pt Ptmini Check for tension
SL NO cover Mu/bd Mulimit/bd2 reinforceme
KN-m mm mm mm N/mm2 N/mm2 % % pt
mm
nt mm2
Remarks
1 211.34 50 300 500 450 3.48 25 415 3.45 1.20 0.20 OK 1624.34 Top
2 139.19 50 300 500 450 2.30 25 415 3.45 0.72 0.20 OK 977.48 Bottom
SHEAR DESIGN
Ast Pt
Vu at provided provided Stirrup Spacing Mini Spacing
SL NO support at at τc τv τc max Check
Dia
Shear legs
Of stirrup Spacing
0.75*d
300 mm Provided
KN support support N/mm
2
N/mm 2
N/mm 2 for τc mm
(Nos)
mm mm
mm
mm
2 2
mm mm
1 122.655 1721 1.27 0.70 0.91 3.1 O.K 8 2 300.00 -- 338.00 300 300.00

PB6 300X500
INPUT SECTION MOMENT DESIGN

req
Effective
Mu b D d 2 fck fy 2 Pt Ptmini Check for tension
SL NO cover Mu/bd 2 2 Mulimit/bd Remarks
KN-m mm mm mm N/mm N/mm % % pt reinforcement
mm 2
mm

1 72.00 50 300 500 450 1.19 25 415 3.45 0.35 0.20 OK 472.4 Bottom
2
SHEAR DESIGN
Ast Pt
Vu at provided provided Stirrup Spacing Mini Spacing
SL NO support at at τc τv τc max Check
Dia
Shear legs
Of stirrup Spacing
0.75*d
300 mm Provided
KN support support N/mm
2
N/mm
2
N/mm
2 for τc mm
(Nos)
mm mm
mm
mm
2 2
mm mm
1 58 628 0.47 0.47 0.43 3.1 O.K 8 2 -- 302.32 338.00 300 300.00

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 75 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

PB7 300X500
INPUT SECTION MOMENT DESIGN

req
Effective
Mu b D d 2
fck fy Pt Ptmini Check for tension
SL NO cover Mu/bd Mulimit/bd2 reinforceme
Remarks
KN-m mm mm mm N/mm2 N/mm2 % % pt
mm 2
nt mm

1 253.06 50 300 500 450 4.17 25 415 3.45 1.42 0.20 OK 1911 Top
2 129.56 50 300 500 450 2.14 25 415 3.45 0.67 0.20 OK 899.7 Bottom
SHEAR DESIGN
Ast Pt
Vu at provided provided Stirrup Spacing Mini Spacing
SL NO support at at τc τv τc max Check
Dia
Shear legs
Of stirrup Spacing
0.75*d
300 mm Provided
KN support support N/mm
2
N/mm 2
N/mm 2 for τc mm
(Nos)
mm mm
mm
mm
2 2
mm mm
1 153.4 1960 1.45 0.73 1.14 3.1 O.K 8 2 300.85 -- 338.00 300 300.00

PB8 300X500
INPUT SECTION MOMENT DESIGN

req
Effective
Mu b D d 2
fck fy Pt Ptmini Check for tension
SL NO cover Mu/bd Mulimit/bd2 reinforcemen
Remarks
KN-m mm mm mm N/mm2 N/mm2 % % pt
mm 2
t mm

1 271.29 50 300 500 450 4.47 25 415 3.45 1.51 0.20 OK 2035.64 Top
2 139.62 50 300 500 450 2.30 25 415 3.45 0.72 0.20 OK 977.48 Bottom
SHEAR DESIGN
Ast Pt
Vu at provided provided Stirrup Spacing Mini Spacing
SL NO support at at τc τv τc max Check
Dia
Shear legs
Of stirrup Spacing
0.75*d
300 mm Provided
KN support support N/mm
2
N/mm 2
N/mm 2 for τc mm
(Nos)
mm mm
mm
mm
2 2
mm mm
1 168 2161 1.60 0.76 1.24 3.1 O.K 8 2 249.43 -- 338.00 300 240.00

PB9 300X500
INPUT SECTION OMENT DESIGN

req
Effective
Mu b D d fck fy Pt Ptmini Check for tension
SL NO cover Mu/bd2 Mulimit/bd2 Remarks
KN-m mm mm mm N/mm2 N/mm2 % % pt reinforcem
mm 2
ent mm

1 223.45 50 300 500 450 3.68 25 415 3.45 1.26 0.20 OK 1707.43 Top
2 139.40 50 300 500 450 2.30 25 415 3.45 0.72 0.20 OK 977.48 Bottom
SHEAR DESIGN
Ast Pt
Vu at provided provided Stirrup Spacing Mini Spacing
SL NO support at at τc τv τc max Check
Dia
Shear legs
Of stirrup Spacing
0.75*d
300 mm Provided
KN support support N/mm
2
N/mm 2
N/mm 2 for τc mm
(Nos)
mm mm
mm
mm
2 2
mm mm
1 124.3 1960 1.45 0.73 0.92 3.1 O.K 8 2 300.00 -- 338.00 300 300.00

4.2.2. ROOF BEAM


RB1 300X500
INPUT SECTION MOMENT DESIGN

req
Effective
Mu b D d fck fy Pt Ptmini Check for tension
SL NO cover Mu/bd2 Mulimit/bd2 reinforcemen
KN-m mm mm mm N/mm2 N/mm2 % % pt
mm
t mm2

1 212.74 40 300 500 460 3.36 25 415 3.45 1.15 0.20 OK 1587.35 Top Rein
2 132.32 40 300 500 460 2.09 25 415 3.45 0.65 0.20 OK 895.25 Bottom Reinf
SHEAR DESIGN
Ast Pt
Vu at provided provided Stirrup Spacing Mini Spacing
SL NO support at at τc τv τc max Check
Dia
Shear legs
Of stirrup Spacing
0.75*d
300 mm Provided
KN support support N/mm
2
N/mm 2
N/mm 2 for τc mm
(Nos)
mm mm
mm
mm
mm2 mm2
1 152.42 1696 1.23 0.69 1.10 3.1 O.K 8 2 293.32 -- 345.00 300 290.00

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 76 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

RB2 300x500
INPUT SECTION MOMENT DESIGN

req
Effective
Mu b D d fck fy Pt Ptmini Check for tension
SL NO cover Mu/bd2 Mulimit/bd2 reinforcem
KN-m mm mm mm N/mm2 N/mm2 % % pt
mm
ent mm2

1 214.80 40 300 500 460 3.39 25 415 3.45 1.16 0.20 OK 1605.97 Top Rein
2 150.17 40 300 500 460 2.37 25 415 3.45 0.75 0.20 OK 1034.63 Bottom Rein
SHEAR DESIGN
Ast Pt
Vu at provided provided Stirrup Spacing Mini Spacing
SL NO support at at τc τv τc max Check
Dia
Shear legs
Of stirrup Spacing
0.75*d
300 mm Provided
KN support support N/mm
2
N/mm 2
N/mm 2 for τc mm
(Nos)
mm mm
mm
mm
2 2
mm mm
1 144.075 1696 1.23 0.69 1.04 3.1 O.K 8 2 343.67 -- 345.00 300 300.00

RB3 230x500
INPUT SECTION MOMENT DESIGN
req
Effective tension
Mu b D d fck fy Pt Ptmini Check for
SL NO cover Mu/bd2 Mulimit/bd2 reinforce
KN-m mm mm mm N/mm2 N/mm2 % % pt
ment
mm
mm2
1 220.00 40 230 500 460 4.53 25 415 3.45 1.52 0.20 OK 1607.23 Bottom Rein
2
Ast Pt
Vu at provided provided Stirrup Spacing Mini Spacing
SL NO support at at τc τv τc max Check
Dia
Shear legs
Of stirrup Spacing
0.75*d 300
Provided
KN support support N/mm
2
N/mm 2
N/mm 2 for τc mm
(Nos)
mm mm
mm mm
mm
2 2
mm mm
1 150 1473 1.39 0.72 1.42 3.1 O.K 8 2 227.33 -- 345.00 300 220.00

RB4 300x500
INPUT SECTION MOMENT DESIGN

req
Effective
Mu b D d fck fy Pt Ptmini Check for tension
SL NO cover Mu/bd2 Mulimit/bd2 reinforcem
KN-m mm mm mm N/mm2 N/mm2 % % pt
mm
ent mm2

1 268.00 40 300 500 460 4.23 25 415 3.45 1.43 0.20 OK 1971.75 Top Reinf
2 130.68 40 300 500 460 2.06 25 415 3.45 0.64 0.20 OK 880.67 Bottom Rein
SHEAR DESIGN
Ast Pt
Vu at provided provided Stirrup Spacing Mini Spacing
SL NO support at at τc τv τc max Check
Dia
Shear legs
Of stirrup Spacing
0.75*d
300 mm Provided
KN support support N/mm
2
N/mm 2
N/mm 2 for τc mm
(Nos)
mm mm
mm
mm
2 2
mm mm
1 183 2186 1.58 0.76 1.33 3.1 O.K 8 2 212.49 -- 345.00 300 210.00

RB5 230X500
INPUT SECTION MOMENT DESIGN

Effective req tension


Mu b D d fck fy Pt Ptmini Check for
SL NO cover Mu/bd2 Mulimit/bd2 reinforcement
KN-m mm mm mm N/mm2 N/mm2 % % pt
mm mm2

1 54.00 40 230 500 460 1.11 25 415 3.45 0.32 0.20 OK 343.82 Bottom Reinf
2
SHEAR DESIGN
Ast Pt
Vu at provided provided Stirrup Spacing Mini
SL NO support at at τc τv τc max Check
Dia
Shear legs
Of stirrup Spacing
0.75*d
300 mm
Spacing
KN support support N/mm
2
N/mm2 N/mm2 for τc mm
(Nos)
mm mm
mm Provided mm
mm2 mm2
1 60 628 0.59 0.52 0.57 3.1 O.K 8 2 300.00 -- 345.00 300 300.00

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 77 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

RB6 230X600
INPUT SECTION MOMENT DESIGN
req
Effective tension
Mu b D d fck fy Pt Ptmini Check for
SL NO cover Mu/bd2 Mulimit/bd2 reinforce
KN-m mm mm mm N/mm2 N/mm2 % % pt
ment
mm
mm2
1 356.00 40 230 600 560 4.94 25 415 3.45 1.64 0.20 OK 2107.35 Top Renif
2 220.22 40 230 600 560 3.06 25 415 3.45 1.02 0.20 OK 1314.22 Bottom Reinf
SHEAR DESIGN
Ast Pt
Vu at provided provided Stirrup Spacing Mini Spacing
SL NO support at at τc τv τc max Check
Dia
Shear legs
Of stirrup Spacing
0.75*d 300
Provided
KN support support N/mm
2
N/mm 2
N/mm 2 for τc mm
(Nos)
mm mm
mm mm
mm
2 2
mm mm
1 254.216 2274 1.77 0.78 1.97 3.1 O.K 8 2 132.80 -- 420.00 300 130.00

RB7 230X600
INPUT SECTION MOMENT DESIGN

req
Effective
Mu b D d 2 fck fy 2 Pt Ptmini Check for tension
SL NO cover Mu/bd 2 2 Mulimit/bd
KN-m mm mm mm N/mm N/mm % % pt reinforcem
mm 2
ent mm

1 364.21 40 230 600 560 5.05 25 415 3.45 1.67 0.20 OK 2149.4 Top Rein
2 214.92 40 230 600 560 2.98 25 415 3.45 0.99 0.20 OK 1271.42 Bottom Reinf
SHEAR DESIGN
Ast Pt
Vu at provided provided Stirrup Spacing Mini
SL NO support at at τc τv τc max Check
Dia
Shear legs
Of stirrup Spacing
0.75*d
300 mm
Spacing
KN support support N/mm
2
N/mm
2
N/mm
2 for τc mm
(Nos)
mm mm
mm Provided mm
2 2
mm mm
1 254.06 2274 1.77 0.78 1.97 3.1 O.K 8 2 132.93 -- 420.00 300 130.00

RB8 300x500
INPUT SECTION MOMENT DESIGN

req
Effective
Mu b D d 2
fck fy Pt Ptmini Check for tension
SL NO cover Mu/bd Mulimit/bd2 reinforcem
KN-m mm mm mm N/mm2 N/mm2 % % pt
mm
ent mm2

1 272.94 40 300 500 460 4.30 25 415 3.45 1.45 0.20 OK 2000.83 Top Reinf
2 136.88 40 300 500 460 2.16 25 415 3.45 0.67 0.20 OK 929.53 Bottom Reinf
SHEAR DESIGN
Ast Pt
Vu at provided provided Stirrup Spacing Mini
SL NO support at at τc τv τc max Check
Dia
Shear legs
Of stirrup Spacing
0.75*d
300 mm
Spacing
KN support support N/mm
2
N/mm 2
N/mm 2 for τc mm
(Nos)
mm mm
mm Provided mm
2 2
mm mm
1 185 2161 1.57 0.75 1.34 3.1 O.K 8 2 206.17 -- 345.00 300 200.00

LINTEL 300X300
INPUT SECTION MOMENT DESIGN

req
Effective
Mu b D d 2
fck fy Ptmini Check for tension
SL NO cover Mu/bd Mulimit/bd2 Pt %
reinforceme
KN-m mm mm mm N/mm2 N/mm2 % pt
mm
nt mm2

1 86.30 40 300 300 260 4.26 25 415 3.45 1.45 0.20 OK 1133.22 Top Rein
2 56.28 40 300 300 260 2.78 25 415 3.45 0.91 0.20 OK 706.95 Bottom Rein
SHEAR DESIGN
Ast Pt
Vu at provided provided Stirrup Mini Spacing
SL NO support at at τc τv τc max Check
Dia
Shear legs Spacing Of
Spacing
0.75*d
300 mm Provided
KN support support N/mm
2
N/mm 2
N/mm 2 for τc mm
(Nos) stirrup mm
mm
mm
mm
mm2 mm2
1 48 1256 1.61 0.76 0.62 3.1 O.K 8 2 -- 302.32 195.00 300 190.00

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 78 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

4.3.0 FOUNDATION DESIGN

Design of Isolated Footing for Control Room Building-F1


Fy
Fz
Foundation Dimension:
Fx
Base Lx (m) 2.25 GL h1 (m)= 0.00
Lz (m) 2.25
Pedestal Px (m) 0.35 h2 (m)= 2.10
Pz (m) 0.50
D (m)= 0.75
Design Summary:

2
Max Bearing Press.: 326.89 KN/m
2
Mz1
Min Bearing Press.: 243.91 KN/m
Min Contact Length: 100%
X-Axis
Mx1

Soil Properties Z-Axis


Safe Bearing Capacity of Soil q safe = 400.0 KN/m2
At depth h2 q q safe + γ x h2
all = 435.7 KN/m2
At depth h2 q all = 1.25 x q safe + γ x h2 535.7 KN/m2

Material Properties:
Minimum 28 Days Compressive of Concrete : FC 25000 KN/m2
Yield Strength of Reinforcing Steel : FY 415000 KN/m2
Density of Structural fill 17 KN/m3
Density of Concrete 25 KN/m3

Load Combination:
Unfactored Loads (in KN m)
LC No. Fx Fy Fz Mx Mz
Case I 9 10.41 897.24 10.46 7.45 7.44
Case II 11 3.30 594.20 81.57 131.15 2.63
Case III 21 32.41 1038 12.48 8.87 34.88

Factored Loads (in KN m)

LC No. Fx Fy Fz Mx Mz
Case I 9 15.62 1345.86 15.69 11.18 11.16
Case II 11 4.94 891.30 122.36 196.73 3.95
Case III 21 5.14 805.00 9.60 13.31 2.25

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 79 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

Check For Bearing Pressure:

Total Substructure Load:


Weight of Pedestal = 0.0 KN
Weight of Footing = 94.9 KN
Weight of Imposed Earth above footing = 112.2 KN
TOTAL = 207.1 KN
Case I:
Axial load P = Fy + SubStructure Load = 1104.3 KN
Moment at base Mx1= Mx + Fz x (h1+h2) = 29.42 KNm
Moment at base Mz1= Mz + Fx x (h1+h2) = 29.30 KNm
Eccentricity,
ex = Mz1 / P = 0.027 m < Lx / 6 Contact Length= 3 x (Lx /2 - ex) / Lx = 100%
ez = Mx1 / P = 0.027 m < Lz / 6 Contact Length= 3 x (Lz /2 - ez) / Lz = 100%

ex / Lx = 0.012 From Table, K= 1.12


ez / Lz = 0.012 Max. Bearing Press.=qmax =K x P / Lx * Lz = 243.91 KN/m < q
2
all = q safe + γ x h2
=> Hence Satisfactory

Case II:
Axial load P = Fy + SubStructure Load = 801.3 KN
Moment at base Mx1= Mx + Fz x (h1+h2) = 302.45 KNm
Moment at base Mz1= Mz + Fx x (h1+h2) = 9.56 KNm
Eccentricity,
ex = Mz1 / P = 0.012 m < Lx / 6 Contact Length= 3 x (Lx /2 - ex) / Lx = 100%
ez = Mx1 / P = 0.377 m > Lz / 6 Contact Length= 3 x (Lz /2 - ez) / Lz = 100%

ex / Lx = 0.005 From Table, K= 2.07


ez / Lz = 0.168 Max. Bearing Press.=qmax =K x P / Lx * Lz = 326.89 KN/m < q
2
all =1.25* q safe + γ x h2
=> Hence Satisfactory
Case III:
Axial load P = Fy + SubStructure Load = 1245.1 KN
Moment at base Mx1= Mx + Fz x (h1+h2) = 35.078 KNm
Moment at base Mz1= Mz + Fx x (h1+h2) = 102.94 KNm
Eccentricity,
ex = Mz1 / P = 0.083 m < Lx / 6 Contact Length= 3 x (Lx /2 - ex) / Lx = 100%
ez = Mx1 / P = 0.028 m < Lz / 6 Contact Length= 3 x (Lz /2 - ez) / Lz = 100%

ex / Lx = 0.037 From Table, K= 1.30


ez / Lz = 0.013 Max. Bearing Press.=qmax =K x P / Lx * Lz = 319.42 KN/m < q
2
all = 1.25*q safe + γ x h2
=> Hence Satisfactory

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 80 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

Design Of Base (Ref. IS-456)


Downward pressure on Base:
2
ws=(Weight of Footing + Weight of Imposed Earth above footing) / Lx . Lz= 40.91 KN/m

Cover to Main Reinf. = C = 65.00 mm


Effective Depth d =(D - C - φ/2)= 0.68 m
Projected Length of Base:
ax
ax = 0.95 m
az = 0.875 m
Flexure
Flexure d
Case I: Section Shear
Factor for Substructure Load = 1.5
2
Factored ws = fws = 61.36 KN/m
Axial load P = Fy + SubStructure Load = 1656.5 KN
qm qs
Moment at base Mx1= Mx + Fz x (h1+h2) = 44.124 KNm qma
Moment at base Mz1= Mz + Fx x (h1+h2) = 43.953 KNm Base Pressure Distribution Diagram
Eccentricity,
ex = Mz1 / P (m) = 0.027 ex / Lx = 0.012 From Table, K= 1.12
ez = Mx1 / P (m) = 0.027 ez / Lz = 0.012 qmax = K x P / Lx * Lz (KN/m2)= 365.87
qmin = (KN/m2) = 280.81
Moment at face of Pedestal= (P/A-6*MX/B*D*D-6*M/D*B*B)
BM in X- Direction = (qm - fws) x ax 2/ 2 + ( qmax - qm ) x ax2/3 = 132.01 KNm / Unit Width
BM in Z- Direction = (qm - fws) x az 2/ 2 + ( qmax - qm ) x az2/3 = 112.35 KNm / Unit Width

Shear at 'd' distance from face of Pedestal=


SF in X- Direction = (qS - fws) x (ax -d) + ( qmax - qS ) x (ax -d)/2 = 81.72 KN / Unit Width
SF in Z- Direction = (qS - fws) x (az -d) + ( qmax - qS ) x (az -d)/2 = 59.55 KN / Unit Width
Case II:
Factor for Substructure Load = 1.5
2
Factored ws = fws = 61.36 KN/m
Axial load P = Fy + SubStructure Load = 1201.9 KN
Moment at base Mx1= Mx + Fz x (h1+h2) = 453.6705 KNm
Moment at base Mz1= Mz + Fx x (h1+h2) = 14.3334 KNm
Eccentricity,
ex = Mz1 / P (m) = 0.012 ex / Lx = 0.005 From Table, K= 2.07
ez = Mx1 / P (m) = 0.377 ez / Lz = 0.168 qmax = K x P / Lx * Lz (KN/m2) = 490.34
qmin = (KN/m2) = -9.10
Moment at face of Pedestal=
BM in X- Direction = (qm - fws) x ax 2/ 2 + ( qmax - qm ) x ax2/3 = 172.59 KNm / Unit Width
2
BM in Z- Direction = (qm - fws) x az / 2 + ( qmax - qm ) x az2/3 = 139.81 KNm / Unit Width
Shear at 'd' distance from face of Pedestal=
SF in X- Direction = (qS - fws) x (ax -d) + ( qmax - qS ) x (ax -d)/2 = 111.64 KN / Unit Width
SF in Z- Direction = (qS - fws) x (az -d) + ( qmax - qS ) x (az -d)/2 = 80.65 KN / Unit Width

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 81 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

Case III:
Factor for Substructure Load = 1.5
2
Factored ws = fws = 61.36 KN/m
Axial load P = Fy + SubStructure Load = 1115.6 KN
Moment at base Mx1= Mx + Fz x (h1+h2) = 33.4566 KNm
Moment at base Mz1= Mz + Fx x (h1+h2) = 13.0327 KNm
Eccentricity,
ex = Mz1 / P (m) = 0.012 ex / Lx = 0.005 From Table, K= 1.09
ez = Mx1 / P (m) = 0.030 ez / Lz = 0.013 qmax = K x P / Lx * Lz (KN/m2) = 240.78
qmin = (KN/m2) = 195.88
Moment at face of Pedestal=
BM in X- Direction = (qm - fws) x ax 2/ 2 + ( qmax - qm ) x ax2/3 = 78.11 KNm / Unit Width
2
BM in Z- Direction = (qm - fws) x az / 2 + ( qmax - qm ) x az2/3 = 66.46 KNm / Unit Width

Shear at 'd' distance from face of Pedestal=


SF in X- Direction = (qS - fws) x (ax -d) + ( qmax - qS ) x (ax -d)/2 = 48.24 KN / Unit Width
SF in Z- Direction = (qS - fws) x (az -d) + ( qmax - qS ) x (az -d)/2 = 35.13 KN / Unit Width

Bottom Reinforcement:
X-Direction:
Maximum Moment Mx = 172.59 KNm / Unit Width
2
Required q n = Mu/bd = 0.38 N/Sqmm.

ρ = Ast = ρ x b x d =
2
0.00108 731.3 mm Providing Bar : # 16
ρmin = Ast (min)
2
0.0012 = 812.4 mm Spacing Required = 247.46 mm

Hence Req #16 @ 247mm c/c


However provide #16 @ 200mm c/c
Z-Direction:
Maximum Moment Mx = 139.81 KNm / Unit Width
2
q n = Mu/bd =
Required 0.31 N/Sqmm.

ρ = Ast = ρ x b x d =
2
0.00088 592.7 mm Providing Bar : # 16
ρmin = Ast (min)
2
0.0012 = 812.4 mm Spacing Required = 247.46 mm

Hence Req #16 @ 247mm c/c


However provide #16 @ 200mm c/c
One-way Shear Check :
Maximum Shear Force at 'd' distance from Pedestal face = V = 111.64 KN / Unit Width
2
Nominal Shear Stress 0.16 N/mm
2
Design Shear Srength of Concrete 0.26 N/mm

'=> Hence Satisfactory

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 82 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

Top Reinforcement:
Maximum fws = 61.36 KN/m2
BM in X - Direction = (fws x ax2/2) = 27.69 KNm
BM in Z - Direction = (fws x a 2
z /2) = 23.49 KNm
X-Direction:
Maximum Moment Mx = 27.69 KNm / Unit Width
2
q n = Mu/bd =
Required 0.06 N/Sqmm.
ρ = Ast = ρ x b x d =
2
0.00019 125.7 mm Providing Bar : # 12
ρmin = Ast (min)
2
0.0012 = 812.4 mm Spacing Required = 139.20 mm

Hence Req #12 @ 139mm c/c


However provide #12 @ 125mm c/c
Z-Direction:
Maximum Moment Mx = 23.49 KNm / Unit Width
2
q n = Mu/bd =
Required 0.05 N/Sqmm.
ρ = Ast = ρ x b x d =
2
0.00016 108.5 mm Providing Bar : # 12
ρmin = Ast (min)
2
0.0012 = 812.4 mm Spacing Required = 139.20 mm

Hence Req #12 @ 139mm c/c


However provide #12 @ 125mm c/c
Punching Shear Check :

Shear at 'd/2' distance from the col face = 1201.11 KN


2
Punching Shear Stress (N/mm ) = 0.402
2
Allowable Shear Stress (N/mm ) = 1.25

'=> Hence Satisfactory.

STABILITY CHECK
Overturning Check
Case 1
Overturning moment in' Z' direction= 29.3 KNm
Restoring moment in' Z' direction= 1242.4 KNm
Factor of safety= 42.4 >1.5 Hence Satisfactory
Overturning moment in' X' direction= 29.4 KNm
Restoring moment in' X' direction= 1242.4 KNm
Factor of safety= 42.2 >1.5 Hence Satisfactory
Case 2
Overturning moment in' Z' direction= 9.6 KNm
Restoring moment in' Z' direction= 901.5 KNm
Factor of safety= 94.3 >1.5 Hence Satisfactory
Overturning moment in' X' direction= 302.4 KNm
Restoring moment in' X' direction= 901.5 KNm
Factor of safety= 3.0 >1.5 Hence Satisfactory

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 83 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

Case 3
Overturning moment in' Z' direction= 102.9 KNm
Restoring moment in' Z' direction= 1400.7 KNm
Factor of safety= 13.6 >1.5 Hence Satisfactory
Overturning moment in' X' direction= 35.1 KNm
Restoring moment in' X' direction= 1400.7 KNm
Factor of safety= 39.9 >1.5 Hence Satisfactory

Sliding check
Coefficient of friction= 0.5
Case 1
Total sliding force= 14.8 KN
Resisting frictional force= 552.2 KN
Factor of safety= 37.4 >1.5 Hence Satisfactory
Case 2
Total sliding force= 81.6 KN
Resisting frictional force= 400.6 KN
Factor of safety= 4.9 >1.5 Hence Satisfactory
Case 3
Total sliding force= 81.6 KN
Resisting frictional force= 622.5 KN
Factor of safety= 7.6 >1.5 Hence Satisfactory

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 84 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

5.0 CONCLUSION

Column

C1, C2 = 350x500mm

Ground Floor

Grade Slab Thickness = 150mm

PB1 to PB9 = 300x500

PB4a = 230x500

First Floor

Slab Thickness = 150mm

RB1, RB2, RB4, RB8 = 300x500mm

RB3, RB5 = 230X500mm

RB6, RB7 = 230X600mm

Lintel = 300X300mm

Foundation

F1 = 2250X2250X 750mm

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 85 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

ANNEXURE - 1

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 86 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

1.0 DESIGN OF SLAB AND BEAM FOR WATER TANK

The slab is designed as one way slab

DL = 0.125x25 =3.125 KN/m2

2.135M Live Load to water supporting slab

Weight of water = 10KN


Empty weight of tank
(10% weight of water) = 1 KN
Total = 11 KN
1.5M
LL to Slab = 11/1.5x2.135

= 3.43 KN/m2 say 4.0 KN/m2


Input:

Thickness of slab, Thk = 125 mm


Clear cover = 20 mm
Main Dia of bar, main dia = 8 mm
Secondary dia of bar, sec dia = 8 mm
Effective length, Eff Lx = 1.5 m DL + LL+FL
2
Finished load, F.L = 0.00 kN/m
2
Live load, L.L = 4.00 kN/m
3
Unit weight of concrete = 25 kN/m 1.5
2
Grade of concrete, fck = 25 N\mm
2
Grade of steel, fy = 415 N\mm

Analysis :
Consider One meter breadth of the slab.
Both sides of the slab are simply supported
Dead load of slab+ Finishes, w = 3.125 kN/m2
2
beinding moment, B.M(dead load) = wlx /8
= 3.125 x 1.5 x 1.5 / 8
= 0.88 kN m
bending moment, B.M(live load) = 4 x 1.5 x 1.5 / 8
= 1.13 kN m
Shear force, S.F(dead load) = 3.125 x 1.5 / 2
= 2.34 kN
Shear force, S.F(live load) = 4 x 1.5 / 2
= 3.00 kN

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 87 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

Design :
The design of slab is done as per IS 456:2000
For dead load + live load combination partial safety factor 1.5 is used (Refer Cls 36.4)
Factored bending moment, Mu = 0.9 x 1.5 + 1.13 x 1.5
= 3.01 kN m
Factored shear force, Vu = 2.3 x 1.5 + 3.00 x 1.5
= 8.01563 kN
Check for Slab Thickness
Effective Thickness of the Slab, = 125 - 20 - 8 / 2
Thk = 101 mm
Effective depth required for Slab, = v(Mu/(0.138 x fck x 1000)) (Ref. Shah & karve)
= v [3.01x 1000 x 1000 / ( 0.138 x 25.00 x 1000 )]
d reqd = 29.52 mm
Provided depth is ok

Calculation of main steel


2
Area of Steel = ( 0.5 fck/fy ) x [ 1-v( 1 - (4.6Mu/(fck x 1000 x d )) ) ] x 1000d
= 0.5 x 25/415 x [ 1-v( 1 - (4.6 x 3.01/(25x 1000 x101x101)) ) ]
= x 1000 x 101
2
AstR = 83.6194 mm
Minimum percentage of steel is = 0.12

Minimun area of the steel = 0.12 % x b x D


= 0.12x 1000 x 125/ 100
AstM = 150 mm2
Area of steel required AstP = 150 mm2
Spacing of main steel = 335 mm Say 200 mm c/c
Maximum allowable spacing = 3d or 300 mm whichever is lesser Cls 26.3
Spacing is less than maximum spacing

Provide8 mm Dia bar @ 200 mm c/c as main steel


Provide distribution steel 0.12 % b x D
= 0.12x 1000 x 125/ 100
AstP = 150 mm2
Spacing of dist.steel = 335 mm
Max. allowable spacing of Dist.steel = 5d or 450 mm whichever is lesser Cls 26.3
Spacing required = 335 mm Say 200 mm c/c
Spacing is less than maximum spacing
Provide8 mm Dia bar @ 200 mm c/c as distribution steel

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 88 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

Check for shear

Design Shear Force = k τc bd , k and τc are calculated below


k = 1.300 Refer Cls 40.2

Actual area of main steel provided = (π x 8 x 8/ 4)x 1000/200


2
= 150.046 mm Depth k
300 1.00
Percentage of steel provided, pt = 100 x Astp / bd 275 1.05
= 0.149 175 1.25
τc = 0.29 N/mm2 Refer IS 456-2000 Table 19 150 1.30

Design Shear Force = .29 x 1000 x 101

Vult = 38.077 KN
Ultimate shear force > Actual shear force , hence ok

Check for Deflection of the slab


Basic span depth ratio for simple supported sla 0.58 x fy x Ast required / Ast provided
fs = 240.7 (assumed Ast provided = Ast required)
= 1/(0.225+0.00322xfs + 0.625xlog 10(pt)
α1 = 1.70
= α1 x 20
Allowable span depth ratio = 1.7 x 20
= 23.7189
= 1.5 x 1000 / 125
Assumed span depth ratio = 12.00

Assumed Span Depth ratio < Allowable span depth ratio

Hence the design is OK.

Design of Simply Supported Beam for Water Tank

Length of Beam = 2.135m


Size of Beam = 200x200mm
Dead Load

Dead load from slab to beam = WL/2 = 3.75x1.5/2


= 2.82 KN/m
Self weight of beam = 0.2x0.2x25

= 1 KN/m

Total Dead load to beam = 3.82 KN/m

SAY= 4 KN/m
Live load from slab to beam = WL/2 = 4 x 1.5/2
= 3.0 KN/m

Total Factored Load = (4 + 3)x1.5


= 10.5 KN/m

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 89 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

Maximum Moment = WL2/8

= 10.5 x 1.52/8

= 2.95 KN-m

Maximum Shear = WL/2

= 10.5 x 1.5/2

= 7.875 KN

INPUT SECTION MOMENT DESIGN

req
Effective
Mu b D d fck fy Ptmini Check for tension
SL NO cover Mu/bd2 Mulimit/bd2 Pt %
reinforceme
KN-m mm mm mm N/mm2 N/mm2 % pt
mm
nt mm2

1 2.95 40 200 200 160 0.58 25 415 3.45 0.17 0.20 Astmini 52.86 Bottom
2
SHEAR DESIGN
Ast Pt
Vu at provided provided Stirrup Mini Spacing
SL NO support at at τc τv τc max Check
Dia
Shear legs Spacing Of
Spacing
0.75*d
300 mm Provided
KN support support N/mm
2
N/mm 2
N/mm 2 for τc mm
(Nos) stirrup mm
mm
mm
mm
2 2
mm mm
1 7.875 402 1.26 0.70 0.25 3.1 O.K 8 2 -- 453.48 120.00 300 120.00

2.0 DESIGN OF LOCAL LINTEL

2.1 Opening ≤ 750mm


Depth of beam = 100mm

Width of beam = 115mm

Beam is designed as simply supported beam

Beam supported at a distance of 200mm on both side

Total length of beam = 750+200+200


= 1150mm
Dead load to beam

Self weight of beam = 0.1 x 0.115x25

= 0.23 KN/m

Weight of wall above Lintel = 0.7x0.115x20


(Ht of wall-0.7m) = 1.61 KN/m

Total Dead Load = 1.84KN/m

Factored Load = 1.5x1.84

= 2.76 KN/m Say 2.8 KN/m

Maximum Moment = WL2/8

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 90 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

= 2.8 x 1.1502/8

= 0.46 KN-m

Maximum Shear = WL/2

= 2.8 x 1.150/2

= 1.61 KN

Local Lintel < = 750mm opening


INPUT SECTION MOMENT DESIGN

req
Effective
Mu b D d fck fy Ptmini Check for tension
SL NO cover Mu/bd2 Mulimit/bd2 Pt %
reinforceme
KN-m mm mm mm N/mm2 N/mm2 % pt
mm
nt mm2

1 0.46 40 115 100 60 1.12 25 415 3.45 0.33 0.20 OK 22.64 Bottom
2
SHEAR DESIGN
Ast Pt
Vu at provided provided Stirrup Mini Spacing
SL NO support at at τc τv τc max Check
Dia
Shear legs Spacing Of
Spacing
0.75*d
300 mm Provided
KN support support N/mm
2
N/mm2 N/mm2 for τc mm
(Nos) stirrup mm
mm
mm
mm
mm2 mm2
1 1.61 100.48 1.46 0.73 0.23 3.1 O.K 8 2 -- 788.66 45.00 300 40.00

2.2 Opening ≤ 1000mm


Depth of beam = 150mm
Width of beam = 230mm
Beam is designed as simply supported beam
Beam supported at a distance of 200mm on both side
Total length of beam = 1000+200+200
= 1450mm
Dead load to beam

Self weight of beam = 0.15 x 0.23x25

= 0.86 KN/m

Weight of wall above Lintel = 0.7x0.23x20


(Ht of wall-0.7m) = 3.22 KN/m
Total Dead Load = 4.08 KN/m

Factored Load = 1.5x4.08

= 6.12 KN/m Say 6.2 KN/m

Maximum Moment = WL2/8

= 6.2 x 1.4502/8

= 1.62 KN-m

Maximum Shear = WL/2


= 6.2 x 1.450/2
= 4.50 KN

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 91 of 92


MAYTAS NAFTOGASBUD JV GSPL203-73-1514
Rev 0

Local Lintel < = 1000mm opening


INPUT SECTION MOMENT DESIGN

req
Effective
Mu b D d fck fy Ptmini Check for tension
SL NO cover Mu/bd2 Mulimit/bd2 Pt %
reinforceme
KN-m mm mm mm N/mm2 N/mm2 % pt
mm
nt mm2

1 1.62 40 230 150 110 0.59 25 415 3.45 0.17 0.20 Astmini 42.54 Bottom
2
SHEAR DESIGN
Ast Pt
Vu at provided provided Stirrup Mini Spacing
SL NO support at at τc τv τc max Check
Dia
Shear legs Spacing Of
Spacing
0.75*d
300 mm Provided
KN support support N/mm
2
N/mm 2
N/mm 2 for τc mm
(Nos) stirrup mm
mm
mm
mm
mm2 mm2
1 4.5 100.48 0.40 0.44 0.18 3.1 O.K 8 2 -- 394.33 83.00 300 80.00

2.3 Opening ≤ 1500mm


Depth of beam = 230mm
Width of beam =300mm
Beam is designed as simply supported beam
Beam supported at a distance of 200mm on both side
Total length of beam = 1500+230+230
= 1960mm
Dead load to beam

Self weight of beam = 0.23 x 0.3x25

= 1.725 KN/m

Weight of wall above Lintel = 0.7x0.23x20


(Ht of wall-0.7m) = 3.22 KN/m
Total Dead Load = 4.945 KN/m

Factored Load = 1.5x4.945

= 7.42 KN/m Say 7.3 KN/m

Maximum Moment = WL2/8

= 7.3 x 1.9602/8

= 3.50 KN-m

Maximum Shear = WL/2

= 7.3 x 1.960/2

= 7.154 KN

DESIGN CALCULATIONS FOR CONTROL ROOM BUILDING Page 92 of 92