Vous êtes sur la page 1sur 6

Replacement Parts List No.

700001600
Revision F 12/2006

Ductless Split System


Wall Mounted Indoor Unit
MWM-F
Cooling Only
MWM-FR
Heat Pump
Sizes 10-25
60 Hz
Note: For AWM / Ascon units use MWM / McQuay

Contents

Parts List Revision History ................................................................................................... 3


Nomenclature
Model Number .................................................................................................................. 4
Serial Number ................................................................................................................... 4
McQuay Complete Unit Part Numbers ............................................................................ 4
Wall Mounted Indoor Unit
MWM 10-15F/FR .............................................................................................................. 5
MWM 20-25F/FR .............................................................................................................. 6

Ductless Split System, Wall Mtd. Indoor, MWM 10-25F/FR, 60 Hz

Rev. F 12/2006

RPL 700001600 / Page 2

Parts List Revision History


Revision
A

B
C
D
E
F

Date
Description
09/04
New
05/2005 Page 5 - Bub #19 McQuay LCD handset pn changed from #04084047723 to #300039436 and
#04084047726 to #300039437.
Filter pns changed from #300042616 to #03080042616 and #300042618 to #03080042618.
Added Defrost Thermistor cooling and heat pump only #A50134039416 and #300042997.
06/2005 Pages 5 & 6 - Defrost Thermistor description is now Defrost Thermistor Cable pn 300040174.
12/2005 Pages 5&6 - Removed the A from any McQuay p/ns that had them.
4/2006 Page 6 - Added another PC board (bub #3) for Heat Pump only pn 300040214.
8/2006 Page 5 - Bub #7, PC Board, Ctrl Mod. U1.4, Heat Pump; p/n 04084043339 is now for 208/230V
and 04084069834 is for 115V.
12/2006 Page 5 - Filter/Electro Static Wall Mount-McQuay pns changed from #03080042616 to 300042616
and Deodorizing wall mount #03080042618 changed to #300042618.
Page 6 - Filter / Electro-Static Wall Mount -McQuay pn was changed from pn 03080042615 to
# 300042615 and Filter/Deodorizing Wall Mount -McQuay pn was changed from 03080042617 to
# 300042617.

13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330

Ductless Split System, Wall Mtd. Indoor, MWM 10-25F/FR, 60 Hz

Rev. F 12/2006

RPL 700001600 / Page 3

Nomenclature
Model Number Nomenclature
M

WM

10

Brand Name
M = McQuay
A = Acson

Vintage/Unit Type
F = F Vintage, Cooling Only
FR = F Vintage, Heat Pump

Unit Type
WM = Wall Mount

Unit Model/Approximate Size


10 = 9,200 Btu
15 = 11,500 Btu
20 = 19,000 Btu
25 = 25,000 Btu

Note: For AWM / Ascon units use MWM / McQuay RPL.

Serial Number Nomenclature


Serial Number Example: 2043XX0Y ZZZZZ

2043

XX

Year of Production
2043 = year 2000
2044 = year 2001
2045 = year 2002
2046 = year 2003 and onwards

ZZZZZ
ZZZZZ = Production unit
running number
Y = Production line (from 1 to 6)
0 = Carries no meaning

XX = The week in the year, (from 1-52)

Example: 2044450100138 means the unit was produced in the Year 2001, Week 45, Line 1, Unit Number
00138.
Note the first week starts from the 1st week of January from 1-7th of January 2001.

McQuay Complete Unit Part Numbers


MWM10F ...................................... 300040056
MWM10FR .................................... 300040088
MWM15F ...................................... 300040057
MWM15FR .................................... 300040089
MWM20F ...................................... 300040058
MWM20FR .................................... 300040090
MWM25F ...................................... 300040059
MWM25FR .................................... 300040091
Ductless Split System, Wall Mtd. Indoor, MWM 10-25F/FR, 60 Hz

Rev. F 12/2006

RPL 700001600 / Page 4

Wall Mounted Indoor Unit


MWM 10-15F/FR

Bub.#
1
2
3
4
7
7
7
7
8
9
10
11
12
13
14
15
15
16
17
18
19
19
N/S
N/S
N/S
N/S

Description
Assy, Mounting Plate
Clamp, Piping, Cooling Only
Assy, Chassis
Fan Motor T31B4P-RC60, Cooling Only
PC Board, Control Module D2.0, Cooling Only
PC Board, Control Module D2.0, F05, Cooling Only
PC Board, Control Mod. U1.4, Heat Pump 208/230V
PC Board, Control Mod. U1.4, Heat Pump 115V
Drain Hose
Assy, Air Discharge Housing
Air Swing Motor, Cooling Only
Air Discharge Louver
Rivet (Grey)
Crossflow Fan 687.0 x 636.0
Fan Bush C/Flow Fan Black
Evaporator Coil Assy.
15F/FR
Evaporator Coil Assy.
10F/FR
Front Cover Assy B UL
Screw Cap UL
Air Filter
LCD G7 Handset, Cooling Only
LCD G7 Handset, Heat Pump
Filter, Electro-Static Wall Mount
Filter, Deodorizing,Wall Mount
Filter, Primary, Wall Mount
Defrost Thermistor Cable (Heat Pump only)

Vendor P/N
A50013032957
A12013040123
A50124039967
A50034035893
A04084040616
A04084046124
A04084043339
A04084069834
A10024018204
A50124039964
A03039004235
A12013039966
A07074027137
A03024032878
A11014029514
A50023032899
A50024036001
A50124039977
A12014039974
A12013029414
A04084047723
A04084047726
A03089016307
A03089016310
A42013029414
A50134039416

McQuay P/N Qty.


50013032957
1
12013040123
1
50124039967
1
50034035893
1
04084040616
1
04084046124
1
04084043339
1
04084069834
1
10024018204
1
50124039964
1
03039004235
1
12013039966
1
07074027137
1
03024032878
1
11014029514
1
50023032899
1
50024036001
1
50124039977
1
12014039974
1
12013029414
1
04084047723
1
04084047726
1
300042616
1
300042618
1
42013029414
2
50134039416
1

N/S=Not shown on diagram

Ductless Split System, Wall Mtd. Indoor, MWM 10-25F/FR, 60 Hz

Rev. F 12/2006

RPL 700001600 / Page 5

Wall Mounted Indoor Unit


MWM 20-25F/FR

5
10

16
1
6
8
3
7

11
9
13

18
12
14

Bub.
No.
1
2
3
3
5
6
6
7
8
8
9
10
11
12
13
14
16
18
18
N/S
N/S
N/S
N/S
N/S

Description
Chassis Assy. (Ivory)
Piping Clamp (Ivory)
PC Board, Control Module D2.0, Cooling Only
PC Board, Control Module D2.0, Heat Pump Only
Mounting Plate Assy.
Fan Motor, RC60 20W, Size 20, Cooling Only
Fan Motor, RC60. Size 25, Cooling Only
Front Cover Assy. (Ivory)
Assy, Evaporator Coil, Size 20
Assy, Evaporator Coil, Size 25
Air Discharge Housing Assy.
Crossflow Fan
Drain Hose Assy.
Filter Frame / Air Filter
Air Swing Motor
Louver
Fan Bush C/Flow Grey
LCD G7 McQuay Cooling
LCD G7 McQuay Heat Pump
Filter, Electro-Static Wall Mount
Filter, Deodorizing,Wall Mount
Filter, Primary, Wall Mount
7-Day Programmable Wall Control
Defrost Thermistor Cable (Heat Pump only)

N/S=Not shown on diagram


Ductless Split System, Wall Mtd. Indoor, MWM 10-25F/FR, 60 Hz

Vendor Number
A50124048671
A12014048672
A04084040615
A50014036133
A50034042638
A50034042639
A50124048679
A50024035803
A50024039846
A50124048674
A03019007388
A10024015319
A12014033576
A03039007088
A12014048673
A11014023775
A04084047723
A04084047726
A03089016306
A03089016309
A12014033576
A04084049451
A50134039416
Rev. F 12/2006

Part
Number
50124048671
12014048672
04084040615
300040214
50014036133
50034042638
50034042639
50124048679
50024035803
50024039846
50124048674
03019007388
10024015319
12014033576
03039007088
12014048673
11014023775
04084047723
04084047726
300042615
300042617
12014033576
04084049451
50134039416

Qty.
1
1
1
1
1
1

1
1

1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1

RPL 700001600 / Page 6