Huawei Technologies Co., Ltd. provides customers with comprehensive technical support
and service. If you purchase the products from the sales agent of Huawei Technologies Co.,
Ltd., please contact our sales agent. If you purchase the products from Huawei
Technologies Co., Ltd. directly, Please feel free to contact our local office, customer care
center or company headquarters.
Website: http://www.huawei.com
Trademarks
All other trademarks and trade names mentioned in this manual are the property of
their respective holders.
Notice
The information in this manual is subject to change without notice. Every effort has
been made in the preparation of this manual to ensure accuracy of the contents,
but all statements, information, and recommendations in this manual do not
constitute the warranty of any kind, express or implied.
Related Manuals
Manual Content
It guides users to use Quidway S3900 Series
Ethernet Switches, in respect of CLI, login,
configuration file management, VLAN,
Quidway S3900 Series Ethernet
management VLAN, voice VLAN, GVRP, port
Switches Operation Manual-
basic configuration, link aggregation, MSTP,
Release 1510
routing protocol, DHCP, and HWPing. It also
explains the acronyms and abbreviations
present in the manual.
It provides detailed descriptions of the
commands available on Quidway S3900 Series
Ethernet Switches about CLI, login, configuration
Quidway S3900 Series Ethernet
file management, VLAN, management VLAN,
Switches Command Manual-
voice VLAN, GVRP, port basic configuration, link
Release 1510
aggregation, MSTP, routing protocol, DHCP, and
HWPing. It also indexes the commands presents
in the manual.
Organization
Quidway S3900 Series Ethernet Switches Installation Manual mainly introduces the
hardware features, installation, configuration and maintenance of S3900 Series
Ethernet Switches. To avoid any possible device damage and personal injury before
the installation and during the installation, please read the manual carefully. The
manual consists of the following chapters:
Chapter 5 Loading Boot ROM and Host Software introduces how to load
BootROM and host software for S3900 Series Ethernet Switches.
Intended Audience
Conventions
I. General conventions
Convention Description
Arial Normal paragraphs are in Arial.
Convention Description
Boldface The keywords of a command line are in Boldface.
Convention Description
Button names are inside angle brackets. For example, click
<>
the <OK> button.
Window names, menu items, data table and field names
[] are inside square brackets. For example, pop up the [New
User] window.
Multi-level menus are separated by forward slashes. For
/
example, [File/Create/Folder].
Format Description
Press the key with the key name inside angle brackets. For
<Key>
example, <Enter>, <Tab>, <Backspace>, or <A>.
Press the keys concurrently. For example, <Ctrl+Alt+A>
<Key1+Key2>
means the three keys should be pressed concurrently.
Press the keys in turn. For example, <Alt, A> means the
<Key1, Key2>
two keys should be pressed in turn.
V. Mouse operation
Action Description
Press and hold the primary mouse button (left mouse
Select
button by default).
Select and release the primary mouse button without
Click
moving the pointer.
VI. Symbols
Eye-catching symbols are also used in the manual to highlight the points worthy of
special attention during the operation. They are defined as follows:
Environmental Protection
This product has been designed to comply with the requirements on environmental
protection. For the proper storage, use and disposal of this product, national laws and
regulations must be observed.
Table of Contents
i
Installation Manual
Quidway S3900 Series Ethernet Switches Table of Contents
ii
Installation Manual
Quidway S3900 Series Ethernet Switches Table of Contents
iii
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
1.1 Introduction
Quidway S3900 Series Ethernet Switches developed by Huawei Technologies Co., Ltd
(hereinafter referred to as Huawei) support L/2/L3 wire speed switching. They are
intelligent NMS-manageable switches intended for the use in a network environment
where high performance, dense port distribution, and ease of installation are required.
Table 1-1 lists the models of the S3900 series.
Number of
Number of Number of
Power 1000 Mbps
Subseries Model 100 Mbps Console
supply uplink
ports ports
ports
24 ×
10Base-T/1
S3924-SI AC 00Base-TX 0 1
Ethernet
ports
24 ×
10Base-T/1 4 ×
S3928P-SI AC 00Base-TX 1000Base- 1
Ethernet X SFP ports
ports
2 ×
Quidway 1000Base-
S3900-SI 24 × X SFP
10Base-T/1 ports,
S3928TP-
AC 00Base-TX 2 × 1
SI
Ethernet 10/100/100
ports 0Base-T
Ethernet
ports
48 ×
10Base-T/1 4 ×
S3952P-SI AC 00Base-TX 1000Base- 1
Ethernet X SFP ports
ports
24 ×
Quidway 10Base-T/1 4 ×
S3928P-P
S3900-PW AC/DC 00Base-TX 1000Base- 1
WR-SI
R-SI Ethernet X SFP ports
ports
1-1
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
Number of
Number of Number of
Power 1000 Mbps
Subseries Model 100 Mbps Console
supply uplink
ports ports
ports
24 ×
10Base-T/1 4 ×
S3928P-EI AC/DC 00Base-TX 1000Base- 1
Ethernet X SFP ports
ports
2 ×
1000Base-
X SFP
24 × ports,
Quidway
S3928F-EI AC/DC 100Base-X 2 × 1
S3900-EI
SFP ports 10/100/100
0Base-T
Ethernet
ports
48 ×
10Base-T/1 4 ×
S3952P-EI AC/DC 00Base-TX 1000Base- 1
Ethernet X SFP ports
ports
24 ×
10Base-T/1 4 ×
S3928P-P
AC/DC 00Base-TX 1000Base- 1
WR-EI
Ethernet X SFP ports
Quidway ports
S3900-PW
R-EI 48 ×
10Base-T/1 4 ×
S3952P-P
AC/DC 00Base-TX 1000Base- 1
WR-EI
Ethernet X SFP ports
ports
Note:
z The S3928P-PWR-SI, S3928P-PWR-EI, and S3952P-PWR-EI provide
over-temperature protection mechanism. When the internal temperature exceeds
65°C (149°F), they will stop providing power from all ports. When the temperature is
below 60°C (140°F), they will continue to provide power from all ports.
z Only the PoE power supply recommended by Huawei can be used for the
S3928P-PWR-SI, S3928P-PWR-EI, and S3952P-PWR-EI. The –48 VDC from the
equipment room cannot be used directly. Otherwise, devices may be damaged.
1-2
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
1.2 S3924-SI
1.2.1 Front Panel
I. Schematic diagram
(1) Port status LED (2) AC power LED (3) Mode LED
(4) Mode button (5) Console port
Figure 1-1 Front panel of the S3924-SI
II. LEDs
The S3924-SI provides one AC power LED, one mode LED, and 24 10/100 Mbps port
status LEDs on its front panel. You can learn how the switch operates by observing the
LEDs listed in Table 1-2.
1-3
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
No data is being
OFF
received/transmitted on the port.
Attribute Description
Connector RJ-45
Number of ports 24
z 10 Mbps, half duplex/full duplex
Rate z 100 Mbps, half-duplex/full duplex
z MDI/MDI-X auto-sensing
Standard IEEE 802.3u
1-4
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
Attribute Description
Transmission distance 100 m (328.08 ft) over category-5 unshielded twisted
over the selected medium pair (UTP) cables
The S3924-SI provides one EIA/TIA-232 compliant Console port for local or remote
configuration.
Attribute Description
Connector RJ-45
Standard Asynchronous EIA/TIA-232
Baud rate 9600 bps (default)
z Connection to ASCII terminals
Service z Connection to a serial interface of a local terminal (a PC for
example) or to a remote terminal through a pair of modems),
where a terminal emulation program is run
I. Schematic diagram
The S3924-SI provides an AC power socket and a grounding screw on the rear panel,
as shown in Figure 1-2.
(1) (2)
The following gives the input voltage specifications for the S3924-SI:
Rated voltage range: 100 VAC to 240 VAC, 50 Hz/60 Hz
Input voltage range: 90 VAC to 264 VAC, 47 Hz to 63 Hz
1-5
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
1.3 S3928P-SI
1.3.1 Front Panel
I. Schematic diagram
II. LEDs
The S3928P-SI provides one AC power LED, one mode LED, one 7-segment digital
LED, twenty-four 10Base-T/100Base-TX Ethernet port status LEDs, and four
1000Base-X SFP port status LEDs on the front panel. You can learn how the switch
operates by observing the LEDs listed in Table 1-5.
1-6
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
1-7
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
1-8
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
The S3928P-SI provides one EIA/TIA-232 compliant Console port for local or remote
configuration. For the attributes, see Table 1-4.
The S3928P-SI provides four 1000Base-X SFP ports numbered 25 to 28 on the front
panel.
SFP modules allow for great flexibility because they are hot swappable and user
configurable.
Table 1-6 lists the available 1000Base-X SFP modules:
Item Model
SFP-GE-SX-MM850-A
SFP-GE-LX-SM1310-A
1000Base-X SFP
SFP optical SFP-GE-LH40-SM1310
module
modules SFP-GE-LH40-SM1550
SFP-GE-LH70-SM1550
SFP electrical module SFP-GE-T
1-9
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
Note:
z The types of 1000Base-X SFP modules may be subject to changes without notice.
Consult Huawei marketing personnel or technical support personnel to obtain the
latest information about SFP modules.
z For specifications for SFP modules, refer to Quidway Low End Series Ethernet
Switches Pluggable Module Manual.
I. Schematic diagram
The S3928P-SI provides an AC power socket and a grounding screw on the rear panel,
as shown in Figure 1-4.
(1) (2)
The following gives the input voltage specifications for the S3928P-SI:
Rated voltage range: 100 VAC to 240 VAC, 50 Hz/60 Hz
Input voltage range: 90 VAC to 264 VAC; 47 Hz to 63 Hz
1.4 S3928TP-SI
1.4.1 Front Panel
I. Schematic diagram
1-10
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
(8) (7)
II. LEDs
The S3928TP-SI provides one AC power LED, one mode LED, one 7-segment digital
LED, twenty-four 10Base-T/100Base-TX Ethernet port status LEDs, two 1000Base-X
SFP port status LEDs, and two 10/100/1000Base-T Ethernet port status LEDs on the
front panel. You can learn how the switch operates by observing the LEDs listed in
Table 1-7.
1-11
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
1-12
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
1-13
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
No data is being
OFF
received/sent on the port.
The S3928TP-SI provides two 1000Base-X SFP ports numbered 25 and 26 on the front
panel.
SFP modules allow for great flexibility because they are hot swappable and user
configurable.
Table 1-6 lists the available SFP modules.
1-14
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
Note:
z The types of 1000Base-X SFP modules may be subject to changes without notice.
Consult Huawei marketing personnel or technical support personnel to obtain the
latest information about SFP modules.
z For specifications for SFP modules, refer to Quidway Low End Series Ethernet
Switches Pluggable Modules Manual.
The S3928TP-SI provides two 10/100/1000Base-T Ethernet ports on the front panel.
For the attributes, see Table 1-8.
Attribute Description
Connector RJ-45
Number of ports 2
z 10/100 Mbps, half duplex/full duplex
Rate z 1000 Mbps, full duplex
z MDI/MDI-X auto-sensing
z IEEE 802.3u
Standard
z IEEE 802.3ab
Transmission distance 100 m (328.08 ft) over the category-5 unshielded
over the selected medium twisted pair (UTP) cable
The S3928P-SI provides one EIA/TIA-232 compliant Console port for local or remote
configuration. For its attributes, see Table 1-4.
I. Schematic diagram
The S3928TP-SI provides an AC power socket and a grounding screw on the rear
panel, as shown in Figure 1-6:
(1) (2)
1-15
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
The following gives the input voltage specifications for the S3928TP-SI:
Rated voltage range: 100 VAC to 240 VAC, 50 Hz/60 Hz
Input voltage range: 90 VAC to 264 VAC, 47 Hz to 63 Hz
1.5 S3952P-SI
1.5.1 Front Panel
I. Schematic diagram
II. LEDs
The S3952-SI provides one AC power LED, one mode LED, one 7-segment digital LED,
forty-eight 10Base-T/100Base-TX Ethernet port status LEDs, and four 1000Base-X
SFP port status LEDs. You can learn how the switch operates by observing the LEDs
listed in Table 1-5.
Attribute Description
Connector RJ-45
1-16
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
Attribute Description
Number of ports 48
z 10 Mbps, half duplex/full duplex
Rate z 100 Mbps, half-duplex/full duplex
z MDI/MDI-X auto-sensing
Standard IEEE 802.3u
Transmission distance over the 100 m (328.08 ft) over the category-5
selected medium unshielded twisted pair (UTP) cable
The S3952P-SI provides one EIA/TIA-232 compliant Console port for local or remote
configuration. For the attributes, see Table 1-4.
The S3952P-SI provides four 1000Base-X SFP ports numbered 49 to 52 on the front
panel.
SFP modules allow for great flexibility because they are hot swappable and user
configurable.
Table 1-6 lists the available SFP modules.
Note:
z The types of 1000Base-X SFP modules may be subject to changes without notice.
Consult Huawei marketing personnel or technical support personnel to obtain the
latest information about SFP modules.
z For specifications for SFP modules, refer to Quidway Low End Series Ethernet
Switches Pluggable Modules Manual.
I. Schematic diagram
The S3952P-SI provides an AC-input power socket and a grounding screw on the rear
panel, as shown in Figure 1-8.
1-17
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
(1) (2)
The following gives the input voltage specifications for the S3952P-SI.
Rated voltage range: 100 VAC to 240 VAC, 50 Hz/60 Hz
Input voltage range: 90 VAC to 264 VAC, 47 Hz to 63 Hz
1.6 S3928P-EI
1.6.1 Front Panel
I. Schematic diagram
II. LEDs
The S3928P-EI provides one AC power LED, one DC power LED, one mode LED, one
7-segment digital LED, twenty-four 10Base-T/100Base-TX Ethernet port status LEDs,
and four 1000Base-X SFP port status LEDs. You can learn how the switch operates by
observing the LEDs listed in Table 1-10.
1-18
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
1-19
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
Flashing green
The port fails POST.
PoE (3 Hz)
OFF ––
1-20
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
Flashing yellow
PoE The port fails to pass POST.
(3 Hz)
mode
OFF ––
The S3928P-EI provides one EIA/TIA-232 compliant Console port for local or remote
configuration. For the attributes, see Table 1-4.
The S3928P-EI provides four 1000Base-X SFP ports numbered 25 to 28 on the front
panel.
SFP modules allow for great flexibility because they are hot swappable and user
configurable.
1-21
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
Note:
z The types of 1000Base-X SFP modules may be subject to changes without notice.
Consult Huawei marketing personnel or technical support personnel to obtain the
latest information about SFP modules.
z For specifications for SFP modules, refer to Quidway Low End Series Ethernet
Switches Pluggable Modules Manual.
I. Schematic diagram
The following gives the input voltage specifications for the S3928P-EI.
z AC power
Rated voltage range: 100 VAC to 240 VAC, 50 Hz/60 Hz
Input voltage range: 90 VAC to 264 VAC, 47 Hz to 63 Hz
z DC power
Rated voltage range: –48 VDC to –60 VDC
Input voltage range: –36 VDC to –72 VDC
1-22
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
1.7 S3928F-EI
1.7.1 Front Panel
I. Schematic diagram
The S3928F-EI provides twenty-four 100Base-X SFP ports, two 1000Base-X SFP ports,
two 10/100/1000Base-T Ethernet ports, and one Console port, as shown in Figure
1-11.
(1) 100Base-X SFP port status LEDs (2) 1000Base SFP port status LEDs
(3) 10/100/1000Base-T Ethernet port status LEDs
(4) Console port (5) 7-segment digital LED
(6) DC power LED (7) AC power LED
(8) Mode LED (9) Mode button
Figure 1-11 Front panel of the S3928F-EI
II. LEDs
The S3928F-EI provides one AC power LED, one DC power LED, one mode LED, one
7-segment digital LED, twenty-four 100Base-X SFP port status LEDs, four 1000Base-X
SFP port status LEDs, and. two 10/100/1000Base-T Ethernet port status LEDs. You
can learn how the switch operates by observing the LEDs listed in Table 1-11.
1-23
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
1-24
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
1-25
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
1-26
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
Item Model
SFP-FE-SX-MM1310-A
SFP-FE-LX-SM1310-A
100Base-X SFP module
SFP-FE-LH40-SM1310
SFP-FE-LH80-SM1550
1-27
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
The S3928F-EI provides two 1000Base-X SFP ports numbered 25 and 26 on the front
panel.
SFP modules allow for great flexibility because they are hot swappable and user
configurable.
Table 1-6 lists the available SFP modules.
Note:
z The types of 1000Base-X SFP modules may be subject to changes without notice.
Consult Huawei marketing personnel or technical support personnel to obtain the
latest information about SFP modules.
z For specifications for SFP modules, refer to Quidway Low End Series Ethernet
Switches Pluggable Modules Manual.
The S3928F-EI provides one EIA/TIA-232 compliant Console port for local or remote
configuration. For the attributes, see Table 1-4.
I. Schematic diagram
The following gives the input voltage specifications for the S3928F-EI.
z AC-input ranges:
1-28
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
1.8 S3928P-PWR-SI/S3928P-PWR-EI
1.8.1 Front Panel
I. Schematic diagram
II. LEDs
1-29
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
1-30
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
1-31
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
1-32
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
1-33
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
Attribute Description
Connector RJ-45
Number of ports 24
z 10/100 Mbps, half duplex/full duplex
Rate z MDI/MDI-X auto-sensing
z PoE remote power supply
z IEEE 802.3u
Standard
z IEEE 802.3af
Transmission distance over 100 m (328.08 ft) over the category-5 unshielded
the selected medium twisted pair (UTP) cable
1-34
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
Note:
SFP modules do not support PoE.
SFP modules allow for great flexibility because they are hot swappable and user
configurable.
Table 1-6 lists the available SFP modules.
Note:
z The types of 1000Base-X SFP modules may be subject to changes without notice.
Consult Huawei marketing personnel or technical support personnel to obtain the
latest information about SFP modules.
z For specifications for SFP modules, refer to Quidway Low End Series Ethernet
Switches Pluggable Modules Manual.
V. Console port
I. Schematic diagram
1-35
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
Note:
Only the PoE power supply recommended by Huawei can be used for the
S3928P-PWR-SI, S3928P-PWR-EI, and S3952P-PWR-EI. The –48 VDC from the
equipment room cannot be used directly. Otherwise, devices may be damaged.
1.9 S3952P-EI
1.9.1 Front Panel
I. Schematic diagram
1-36
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
II. LEDs
The S3952P-EI provides one AC power LED, one DC power LED, one mode LED, one
7-segment digital LED, forty-eight 10Base-T/100Base-TX Ethernet port status LEDs,
and four 1000Base-X SFP port status LEDs. You can learn how the switch operates by
observing the LEDs listed in Table 1-10.
The S3952P-EI provides four 1000Base-X SFP ports numbered 49 to 52 on the front
panel.
SFP modules allow for great flexibility because they are hot swappable and user
configurable.
Table 1-6 lists the available SFP modules.
Note:
z The types of 1000Base-X SFP modules may be subject to changes without notice.
Consult Huawei marketing personnel or technical support personnel to obtain the
latest information about SFP modules.
z For specifications for SFP modules, refer to Quidway Low End Series Ethernet
Switches Pluggable Modules Manual.
V. Console port
The S3952P-EI provides one EIA/TIA-232 compliant Console port for local or remote
switch configuration. For its attributes, see Table 1-4.
I. Schematic diagram
1-37
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
The following gives the input voltage specifications for the S3952P-EI.
z AC power
Rated voltage range: 100 VAC to 240 VAC, 50 Hz/60 Hz
Input voltage range: 90 VAC to 264 VAC, 47 Hz to 63 Hz
z DC power
Rated voltage range: –48 VDC to –60 VDC
Input voltage range: –36 VDC to –72 VDC
1.10 S3952P-PWR-EI
1.10.1 Front Panel
I. Schematic diagram
(6)
(8) (7)
II. LEDs
The S3952P-PWR-EI provides one AC power LED, one DC power LED, one mode
LED, one 7-segment digital LED, forty-eight 10Base-T/100Base-TX Ethernet port
status LEDs, and four 1000Base-X SFP port status LEDs. You can learn how the switch
operates by observing the LEDs listed in Table 1-13.
1-38
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
Attribute Description
Connector RJ-45
Number of ports 48
z 10/100 Mbps, half duplex/full duplex
Rate z MDI/MDI-X auto-sensing
z PoE
z IEEE 802.3u
Standard
z IEEE 802.3af
Transmission distance over 100 m (328.08 ft) over the category-5 unshielded
the selected medium twisted pair (UTP) cable
Note:
SFP modules do not support PoE.
SFP modules allow for great flexibility because they are hot swappable and user
configurable.
Table 1-6 lists the available SFP modules.
Note:
z The types of 1000Base-X SFP modules may be subject to changes without notice.
Consult Huawei marketing personnel or technical support personnel to obtain the
latest information about SFP modules.
z For specifications for SFP modules, refer to Quidway Low End Series Ethernet
Switches Pluggable Modules Manual.
1-39
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
V. Console port
The S3952P-PWR-EI provides one EIA/TIA-232 compliant Console port for local or
remote switch configuration. For its attributes, see Table 1-4.
I. Schematic diagram
The following give the input voltage specifications for the S3952P-PWR-EI.
z AC power
Rated voltage range: 100 VAC to 240 VAC, 50 Hz/60 Hz
Input voltage range: 90 VAC to 264 VAC, 47 Hz to 63 Hz
z DC power
Input voltage range: –52 VDC to –55 VDC
Note:
Only the PoE power supply recommended by Huawei can be used for the
S3928P-PWR-SI, S3928P-PWR-EI, and S3952P-PWR-EI. The –48 VDC from the
equipment room cannot be used directly. Otherwise, devices may be damaged.
1-40
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
24 ×
10Base-T/10
0Base-TX
24 × Ethernet 48 ×
10Base-T/10 ports 10Base-T/10
24 × 0Base-TX 0Base-TX
Ethernet 2 × Ethernet
Number of fixed 10Base-T/100
ports 1000Base-X ports
ports Base-TX
SFP ports
Ethernet ports 4 × 4 ×
1000Base-X 2 × 1000Base-X
SFP ports 10/100/1000 SFP ports
Base-T
Ethernet
ports
Number of
management 1 × Console port
ports
AC power
Power system z Rated voltage range: 100 VAC to 240 VAC, 50 Hz/60 Hz
z Input voltage range: 90 VAC to 264 VAC, 50 Hz/60 Hz
PoE (as a Not Not Not
Not supported
powered device) supported supported supported
System power
consumption (full 30 W 40 W 40 W 50 W
load)
Operating
0°C to 45°C (32°F to 113°F)
temperature
Relative humidity
10% to 90%
(noncondensing)
1-41
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
24 × 100Base-X
24 × SFP ports 48 ×
10Base-T/100Bas
2 × 1000Base-X 10Base-T/100Base
Number of fixed e-TX Ethernet
SFP ports -TX Ethernet ports
ports ports
2 × 4 × 1000Base-X
4 × 1000Base-X
10/100/1000Base-T SFP ports
SFP ports
Ethernet ports
Number of
management 1 × Console port
ports
z AC power
Rate voltage range: 100 VAC to 240 VAC, 50 Hz/60 Hz
Input voltage range: 90 VAC to 264 V AC, 47 Hz to 63 Hz
Power system
z DC power
Rate voltage range:–48 VDC to –60 VDC
Input voltage range: –36 VDC to –72 VDC
PoE (as a
Not supported Not supported Not supported
powered device)
System power
consumption (full 40 W 65 W 50 W
load)
Operating
0°C to 45°C (32°F to 113°F)
temperature
Relative humidity
10% to 90%
(noncondensing)
1-42
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 1 Product Overview
48×
24 × 10Base-T/100Base-TX Ethernet 10Base-T/100Base-T
Number of fixed ports X Ethernet ports
ports
4 × 1000Base-X SFP ports 4 × 1000Base-X SFP
ports
Number of
management 1 × Console port
ports
z AC power
Rated voltage range: 100 VAC to 240 VAC, 50 Hz/60 Hz
Power system Input voltage range: 90 VAC to 264 VAC, 47 Hz to 63 Hz
z DC power
Input voltage range: –52 VDC to –55 VDC
PoE (as a
Supported Supported Supported
powered device)
z 465 W(AC input)
z 450 W (AC input)
Dissipated power: 165
Dissipated power: 150 W
W
System power PoE: 300 W
consumption (full PoE: 300 W
load) z 430 W (DC input)
z 820 W (DC input)
Dissipated power: 60 W
Dissipated power: 80 W
PoE: 370 W
PoE: 740 W
Operating
0°C to 45°C (32°F to 113°F)
temperature
Relative humidity
10% to 90%
(noncondensing)
1-43
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 2 Preparation
Chapter 2 Preparation
2.2.1 Temperature/Humidity
You must maintain a proper temperature and humidity in the equipment room.
Long-term high humidity may lead to bad insulation, electricity leakage, mechanical
property changes, and corrosion. However, if the relative humidity is two low, captive
screws may become loose as the result of contraction of insulation washers and static
electricity may be produced in a dry environment to jeopardize the CMOS circuits on
the device. High temperature is the most undesirable condition, because it accelerates
2-1
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 2 Preparation
aging of insulation materials and can thus significantly lower reliability and service life of
your switch.
For the temperature and humidity requirements of different models, refer to section
1.11 “Features of the S3900 Series”.
2.2.2 Cleanness
Dust is a hazard to the operating safety of your device. The dust accumulated on the
chassis can be adsorbed by static electricity and result in poor contact of metal
connectors or metal contact points. This can not only shorten the service life of your
device but also cause communications failures. When the relative indoor humidity is
low, electrostatic adsorption is more likely to happen. The contents of the dust must be
limited as shown in Table 2-1:
Besides dust, there are rigorous limits on the harmful gases that can accelerate the
erosion and aging of metals, such as salts, acids, and sulfides, as shown in Table 2-2.
Cl2 0.01
2-2
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 2 Preparation
z For the AC power supply that adopts TN system, use a single-phase three-line
power socket with Protection Earth (PE) to effectively filter interference from the
power grid.
z Keep the device far from radio transmitting stations, radar stations, and
high-frequency devices.
z Use electromagnetic shielding when necessary, for example, use shielded
interface cables.
z Route interface cables only indoors to prevent signal ports from getting damaged
by over-voltage or over-current caused by lightning strikes.
Caution:
Staring into the laser beam produced by the fiber can hurt your eyes.
Caution:
The installation tools are not provided with the S3900 series.
2-3
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 3 Installation
Chapter 3 Installation
Caution:
When you ask your sales agent to maintain the switch, you must ensure that the
dismantlement-preventive seal on a mounting screw of the switch chassis is intact. If
you want to open the chassis, you should contact the agent for permission. Otherwise,
you will bear any consequence resulted from your actions without permission.
You can install the S3900 series into a 19-inch standard cabinet in one of the following
ways:
z Use front mounting ears
z Use front mounting ears and a tray
z Use front mounting ears and rear mounting ears
The installation methods depend on the width and depth of the switch. For the specific
installation methods, see Table 3-1.
Table 3-1 Installation methods for a switch with a width of 440 mm (17.3 in)
Note:
When the width of a switch is greater than 300 mm (11.8 in), the front mounting ears
only secure the switch rather than bear its weight.
3-1
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 3 Installation
(1): Screw hole used to fix the mounting ear to the cabinet (Use one M6 screw)
(2): Screw hole used to fix the switch to the mounting ear
Figure 3-1 Appearance of a front mounting ear
(1): Screw hole used to fix the mounting ear to the cabinet (Use one M6 screw)
Figure 3-2 Appearance of a rear mounting ear
When you install the S3900 series into 19” standard cabinets, you should select front
and rear mounting ears listed in Table 3-2.
3-2
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 3 Installation
Configuration
Physical Configuration
type of front
Model dimensions (H × type of rear
mounting
W × D) mounting ears
ears
z Quidway S3924-SI
z Quidway S3928P-SI
z Quidway S3928TP-SI 43.6 × 440 × 260
z Quidway S3952P-SI mm (1.7 × 17.3 × Standard —
z Quidway S3928P-EI 10.2 in)
z Quidway S3928F-EI
z Quidway S3952P-EI
z Quidway
S3928P-PWR-SI
43.6 × 440 × 420
z Quidway
mm (1.7 × 17.3 × Standard Standard
S3928P-PWR-EI
16.5 in)
z Quidway
S3952P-PWR-EI
Front panel
3) Place the switch horizontally in a proper position, and fix the other end of mounting
ears to the front brackets with screws and captive nuts, as shown in Figure 3-4.
3-3
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 3 Installation
Front panel
Front
mounting ear
3-4
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 3 Installation
Three installation locations for screw 1 (select one according to the actual requirement)
Screw 1
Screw 1 Front
Front panel mounting ear
Note:
There are three positions to mount a load-bearing screw on both sides of a switch. You
should select a proper position according to the actual requirements. The rear
mounting ears tightly contacted with the load-bearing screws can support the switch.
4) Select a position to install the switch and fix the rear mounting ears to the rear
brackets with screws and captive nuts, as shown in Figure 3-6.
3-5
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 3 Installation
5) Hold the bottom of the switch with one hand and the front part of the switch with
the other hand, and pull the switch into the cabinet gently, as shown in Figure 3-7.
Screw 1
After the switch is pushed into the cabinet, ensure that the upper edge of rear mounting
ears is tightly contacted with the load-bearing screw, as shown in Figure 3-8.
Rear square-
Rear panel holed bracket Screw 1
3-6
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 3 Installation
6) Fix the other end of the front mounting ears to the front brackets with screws and
captive nuts and ensure that front and rear mounting ears have fixed the switch in
the cabinet securely, as shown in Figure 3-9.
Screw 1
Rear
mounting ear
Front panel
You are recommended to use a single-phase three-line power socket with a ground
contact or a general purpose PC power socket, making sure that the power point is well
connected to building ground. Normally, the ground point of the power source in a
building was buried in the ground during the construction and wiring. Still, you must
make sure of that.
3-7
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 3 Installation
Step 1: Connect one end of the chassis ground wire to the grounding screw on the rear
of the chassis and the other end to the ground as near as possible.
Step 2: Connect one end of the power cord to the power socket on the rear of the
chassis, and plug the other end to the AC power jack of the power source.
Step 3: Check that the PWR LED on the front panel of the switch is ON.
Caution:
+ - NULL
Step 1: Connect one end of the chassis ground wire to the grounding screw on the rear
of the chassis and the other end to the ground as near as possible.
Step 2: Connect DC-input socket.
3-8
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 3 Installation
Screw 1 Screw 2
Screw 3
Cable 1 Dust-proof shield
Cable tie
2) As shown in Figure 3-12, first insert two cables into the appropriate holes through
dust-proof shield, and then fix the cables separately by using screws 1 and 2.
Make sure that the positive and negative ends of the cable are inserted
appropriately and accord with silkscreen on the holes.
3) Fix the dust-proof shield by screws 3 and 4 by using a small flathead screwdriver,
see Figure 3-12.
4) Enlace the two cables to the polarizing key at the back of the dust-proof shield
using the cable tie, see Figure 3-12.
Connector
component
Screw 2
Screw 1
Cabinet
Step 3: After installing connector component, directly insert the component into
DC-input socket on the cabinet, and then fix the screws 1 and 2 carried by the
connector itself to the appropriate holes on the cabinet socket using a small flathead
screwdriver, see Figure 3-13.
Step 4: Check that the RPS LED on the front panel of the switch is ON.
3-9
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 3 Installation
Caution:
Caution:
Correctly connecting the switch ground wire is crucial to the lightning protection and
electromagnetic susceptibility (EMS) of a switch.
The power input end of the switch is connected with a noise filter, whose central ground
is directly connected to the chassis, forming the chassis ground (commonly known as
PGND). This chassis ground must be securely connected to the earth ground so that
the faradism and leakage electricity can be safely released to the ground, enhancing
the EMS capability of the switch.
Ground your switch as follows:
z When a grounding strip is available at the installation site, attach one end of the
yellow/green ground wire of the switch to the grounding screw on the grounding
strip and fasten the captive nut. (Note that the fire main and lightning rod of a
building are not suitable for grounding the switch. The ground wire of the switch
should be connected to the grounding device for the equipment room.)
3-10
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 3 Installation
(2)
(3)
(1)
(4)
(1) Power input on the switch (2) Grounding screw on the switch
(3) Ground wire (4) Grounding strip
Figure 3-14 Grounding the switch through a grounding strip
z When there is no grounding strip but earth near the equipment room that allows a
grounding body to be buried, hammer an angle iron/steel pipe longer than 0.5 m
into the earth, weld the yellow-green ground wire of the switch onto the angle
iron/steel pipe, and process the joint against erosion.
(2)
(3)
(1)
(4)
(5)
3-11
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 3 Installation
(1)
(3)
(2)
(6)
(4) (5)
z For a DC-powered switch, if none of the first two conditions is available, ground it
through the return wire (RTN) of the DC power supply. In this case, make sure this
RTN wire is well connected to the ground at the DC output of the DC power
cabinet.
(1)
(11)
(2) (3)
(4) (5)
(10) (9)
(6)
(8)
(7)
(1) AC/DC power cabinet (2) -48V strip (3) -48V (4) RTN strip
(5) RTN (6) PGND strip (7) Grounding (8) Ground wire
(9) Grounding screw (10) Ethernet switch (11) DC-input
Figure 3-17 Grounding through the PGND of a power cabinet
Caution:
S3900-EI Series Ethernet Switches have both AC and DC power inputs, so ensure that
all the power connections are disconnected before you turn off the power.
3-12
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 3 Installation
Caution:
z After a switch starts, the PON interface may emit invisible radial when there is no
optical connector connected to it and the protective cap is removed from it.
Therefore, do not stare into the optical interface.
z Be sure to cover the protective cap within 10 seconds if an optical connector is not in
use to keep the optical connector clean.
z Be sure to cover the protective cap if a PON interface has no optical connector
attached.
z Place the protective caps in a safe place when a PON interface has fiber connected
to prepare for the cases the fiber is pulled out.
Console cable is an 8-core cable. At one end of the cable is a crimped RJ-45 connector
to the Console port of the switch, and at the other end of the cable is a DB-9 (female)
connector to the serial port on the console terminal. See Figure 3-18.
3-13
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 3 Installation
Follow these steps to connect a terminal device, a PC for example, to the switch:
Step 1: Plug the DB-9 (female) connector of the Console cable to the serial port of the
PC where the switch is to be configured.
Step 2: Connect the RJ-45 connector of the console cable to the Console port of the
switch.
Caution:
Read the mark for the port to be connected carefully to make sure it is the right port.
Note:
The serial ports on PCs do not support hot swapping. Therefore, do not insert or
remove a serial interface cable from a PC that is connected to a switch with power. In
connecting a PC to the switch, first connect the DB-9 connector of the console cable to
the PC and then the RJ-45 connector to the switch. In disconnecting them, remove the
RJ-45 connector prior to the DB-9 connector.
As shown in Figure 3-19, the special stack interconnect cables, 1.5 meters (59.1 in)
long, are used to connect fabric ports (1000Base-X SFP ports on the front panel) in an
intelligent resilient framework (IRF) consisting of multiple S3900 series.
3-14
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 3 Installation
In the case of stack connection, besides special stack interconnect cables, the
combination of SFP modules with cables or optical fibers is permissible. For the models
of SFP modules, see Table 1-6.
Note:
z Special stack interconnect cables for the S3900 series are hot swappable.
z Avoid pulling the special stack interconnect cables while removing the connector.
3-15
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 3 Installation
z All the interface cables are routed indoors. If there are cables outdoors, check that
the socket strip with lightning protection and lightning arresters for network ports
have been correctly connected.
3-16
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 4 Starting up the Switch at the Initial Boot
Switch
Console port
Serial port
Console cable
PC
Figure 4-1 Network diagram for configuring the switch at initial boot
4-1
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 4 Starting up the Switch at the Initial Boot
The HyperTerminal window displays the Connection Description dialog box, as shown
in Figure 4-2.
Step 2: Enter the name of the new connection in the Name field and click <OK>. The
dialog box, as shown in Figure 4-3 displays. Select the serial port to be used from the
Connect Using dropdown menu. The serial port must be the same port connected by
the console cable.
4-2
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 4 Starting up the Switch at the Initial Boot
Step 3: Click <OK>. The Port Settings tab, shown in Figure 4-4, appears and you can
set serial port parameters. Set the following parameters:
z Bits per second: 9600
z Data bit: 8
z Parity check: none
z Stop bit: 1
z Flow control: none
Step 4: Click <OK>. The HyperTerminal dialogue box appears, as shown in Figure 4-5.
4-3
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 4 Starting up the Switch at the Initial Boot
In the HyperTerminal dialogue box, select [File/Properties]. The Properties dialog box
appears. In the Properties dialog box, select the Settings tab, as shown in Figure 4-6.
Select VT100 or Auto detect in the Emulation dropdown menu. Click <OK>.
4-4
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 4 Starting up the Switch at the Initial Boot
For the models in the S3900 series, the displayed Boot ROM information is similar.
Following is the Boot ROM information displayed on the S3924-SI:
Starting......
***********************************************************
* *
* Quidway S3952P-EI BOOTROM, Version 306 *
* *
***********************************************************
4-5
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 4 Starting up the Switch at the Initial Boot
...................................................................
...............................................OK!
Starting at 0x80100000...
Make sure you already understand that it takes a relative long time for the system to
boot with full startup mode because it must perform some self-test operations.
Press <Y>. The following information appears:
Setting startup mode...done!
BOOT MENU
4-6
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 4 Starting up the Switch at the Initial Boot
Press <0>. The system reboots with full startup mode and displays the following
information:
Starting......
***********************************************************
* *
* Quidway S3952P-EI BOOTROM, Version 306 *
* *
***********************************************************
To enter the Boot Menu, press <Ctrl+B> within five seconds after the message “Press
Ctrl-B to enter Boot Menu... 5” appears. If not, the system automatically boots and
displays:
Auto-booting...
Decompress
Image..............................................................
...................................................................
...................................................................
...................................................................
...................................................................
...............................................OK!
Starting at 0x80100000...
Initialize LSJ1LTSE........................OK!
SDRAM fast selftest........................OK!
Flash fast selftest........................OK!
CPLD selftest..............................OK!
Switch chip selftest.......................OK!
PHY selftest...............................OK!
4-7
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 4 Starting up the Switch at the Initial Boot
The appearance of “Press ENTER to get started” indicates that the switch has
completed its automatic boot.
Press <Enter>; the system displays:
<Quidway>
Note:
z If the specified host software does not exist, the switch will automatically choose
currently valid host software to boot.
z A wide range of command views are available for Quidway Series Switches. For
more information on configuration commands and command line interfaces, refer to
Quidway S3900 Series Ethernet Switches Operation Manual and Quidway S3900
Series Ethernet Switches Command Manual.
4-8
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software
Switch software loading through serial ports in the past is time consuming and cannot
be operated remotely. To address these problems, TFTP and FTP are used to allow
software and file downloading through Ethernet ports. The following subsections
describe how to load software and files in these two approaches.
Note:
Ensure that the Boot ROM and host software versions that you download can work with
each other.
In Boot ROM, application files, configuration files, and Web files support three kinds of
attributes: main, backup, and none, which are described in Table 5-1.
5-1
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software
Note:
z The suffixes of application, configuration, and Web files are app, cfg, and web
respectively.
z A file can have both the main attribute and the backup attribute. Such a file is
displayed with identification of (*b).
If you specify a file to have the main attribute when there is already a main boot file, the
original main boot file will lose the main attribute, ensuring that only one application file,
one configuration file, and one web file in the Flash have the main attribute. The same
is true for the backup attribute.
Operations of a file are separate from those of the attributes. For example, when you
delete a main boot file from the Flash, the main attribute of the file remains. If you
download a valid file with the same name to the Flash, the new file will have the main
attribute.
The file attribute feature is backward compatible. When you upgrade the Boot ROM of a
device, the original default app boot file has the main attribute.
I. Downloading
When you download an application, configuration, or Web file from the boot menu
through TFTP or FTP, the device identifies the file by its suffix and checks the validity of
the file if it is an app file. Then, the device displays a message for you to confirm if you
want to set it as a boot file. You can set file attributes at prompt.
Note:
If a downloaded file has the same name as that of an existing file in the Flash, the new
file will overwrite the original one, while having the same attributes.
5-2
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software
II. Booting
When a device boots, it first uses the application file with the main attribute. If the boot
operation fails, the device selects the application file with the backup attribute to try
again. If the boot operation fails again, the device displays an error message and
repeats the above procedure.
Note:
z If the device boots failed with an application file with main attribute, it will display an
alert message.
z If the specified application file does not exist, the switch will automatically choose an
existing valid application file to boot.
You can set the attribute of a file from the Boot menu.
The following takes an application file for example to describe the required steps:
I. Enter the Boot menu and input 2 to select “2. Select application file to boot”
and enter the corresponding submenu.
5-3
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software
When setting the attribute of a file, you can use the strings listed in the following table.
The strings are case-insensitive.
If a file has neither the main attribute nor the backup attribute after you change the
attributes of other files, the device will give the file the attribute of none and display an
alert message.
IV. If you change the attribute of an application file to main, the device will
display a message for you to confirm whether you want to boot the device
immediately.
If you enter y, the device will reboot immediately. If you enter n, the device will return to
the [Select application file to boot] submenu.
5-4
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software
Note:
The steps that you should take to load Boot ROM program and host software are the
same, except that during Boot ROM program loading you need to press <Ctrl +U> after
accessing the Boot ROM menu and will view different prompt information. Boot ROM
loading procedures are described below for example.
Starting......
***********************************************************
* *
* Quidway S3952P-EI BOOTROM, Version 306 *
* *
***********************************************************
Note:
To access the Boot Menu, press <Ctrl+B> within two seconds after the information
“Press Ctrl-B to enter Boot Menu...” appears; otherwise the system starts to
decompress the program. At this time if you want to access the Boot Menu, you need to
restart the switch.
Input the correct Boot ROM password (no password is set by default). The system
enters the following Boot Menu:
5-5
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software
BOOT MENU
I. Introduction to XModem
XModem is a file transfer protocol widely used for its simplicity and good performance.
XModem transfers files through the Console port, supporting data packets of 128 bytes
and 1 KB. With respect to reliability, it supports checksum, CRC, and the error packet
retransmission mechanism. Normally, the maximum number of retransmission
attempts is ten.
XModem transfer is completed by receiving and sending programs together. Receiving
program initiates packet checking method negotiation by sending the negotiation
character. If negotiation passes, the sending program starts packet transfer. Upon
receipt of a complete packet, the receiving program checks it using the agreed-upon
check method. If the check succeeds, the receiving program sends an
acknowledgement character; if the check fails, it sends a reject character. Upon receipt
of the acknowledgement, the sending program continues to send the next packet; upon
receipt of the reject, it retransmits the packet.
5-6
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software
Step 2: Enter <3> in the loading menu to download through XModem. The system
displays the following download speed setting menu:
Please select your download baudrate:
1.* 9600
2. 19200
3. 38400
4. 57600
5. 115200
0. Return
Enter your choice (0-5):
Step 3: Choose an appropriate download baud rate. Enter <5> for example to
download at 115200 bps. The system displays the following information:
Download baudrate is 115200 bps
Please change the terminal's baudrate to 115200 bps and select XMODEM protocol
Press enter key when ready
Note:
You do not need to modify the HyperTerminal’s baud rate if you have chosen 9600 bps,
and thus can skip Steps 4 through 6 and proceed to Step 7 directly. At this time, the
system does not display the above information.
5-7
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software
5-8
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software
Step 5: Click <Disconnect> to disconnect the HyperTerminal from the switch and then
click <Connect> to re-establish the connection, thus validating the baud rate setting.
Note:
After changing terminal’s baud rate, you must disconnect and connect the terminal
emulation program to validate the new configuration.
5-9
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software
Step 6: Press <Enter> to start program loading. The system displays the following
information:
Now please start transfer file with XMODEM protocol.
If you want to exit, Press <Ctrl+X>.
Loading ...CCCCCCCCCC
Step 7: Select [Transfer/Send File] in the HyperTerminal’s window, and in the popup
dialog box similar to Figure 5-4 click <Browse>, select the software you need to
download, and set the protocol to XModem.
Step 9: After completing loading, the system displays the following information:
Loading ...CCCCCCCCCC done!
5-10
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software
Note:
You do not need to reset the HyperTerminal’s baud rate and can skip the last step if you
have chosen 9600 bps. In this case, the system does not display the above prompt
message but “BootROM is updating now.....................................done!” instead.
Step 10: Reset HyperTerminal’s baud rate to 9,600 bps with reference to Steps 5 and 6
described above. Then, press any key as prompted. The system will display the
following information when it completes the loading.
Bootrom updating.....................................done!
Select <3>. The subsequent steps are the same as those for loading Boot ROM, except
for the program to be downloaded in prompt messages.
I. Introduction to TFTP
Trivial File Transfer Protocol is a TCP/IP protocol used for file transfer between clients
and servers. It uses UDP to provide unreliable data stream transfer service.
Step 1: Select an Ethernet port on the switch for loading and connect it to the PC where
the file to be downloaded is stored. (You must know PC’s IP address). Besides, connect
the Console port on the switch to an external PC. This PC can be the same one that
stores the file to be downloaded.
Step 2: Run the TFTP Server program on the PC connected to the Ethernet port, and
specify the path for program loading.
5-11
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software
Caution:
TFTP Server program is not provided with the Quidway Series Switches.
Step 3: Run terminal emulation program on the PC that is connected to the Console
port. Start the switch, access the Boot Menu, and then enter the download protocol
menu.
To download the Boot ROM program, enter <6> or <Ctrl + U> to access the menu for
Boot ROM downloading when the system displays: “Enter your choice(0-9):”
Bootrom update menu:
Step 4: In the download protocol menu, press <1>to select TFTP protocol to download
Boot ROM or host software. Press <Enter>. The system displays the following
information:
Load File name
Switch IP address ←(This address and the server IP address must be on the same
network segment)
Server IP address ← (IP address of the PC where the file is stored)
Step 5: Input the TFTP parameter values and press <Enter>. The system displays the
following information:
Are you sure to update your bootrom?Yes or No(Y/N)
Step 6: Press <Y> to start file downloading and <N> to return to the program
downloading menu. Suppose you press <Y> and then <Enter>. The system starts Boot
ROM program downloading and automatically starts Boot ROM loading. After finishing
loading, it displays the following information:
Loading........................................done
Bootrom updating..........done!
5-12
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software
Select <1>. The subsequent steps are the same as those for loading Boot ROM, except
for the program to be downloaded in prompt messages.
I. Introduction to FTP
With an Ethernet port, you can also use the switch as the FTP server or client to
download or configuration files. The following subsections describe how to load
software by using the switch as the FTP client for example.
Step 1: Select an Ethernet port on the switch for loading and connect it to the PC where
the file to be downloaded is stored. (You must know PC’s IP address). Besides, connect
the Console port on the switch to an external PC. This PC can be the same one that
stores the file to be downloaded.
Step 2: Run the FTP Server program on the PC that is connected to the Ethernet port,
and specify the path for program loading.
Step 3: Run terminal emulation program on the PC connected to the Console port. Start
the switch, access the Boot Menu, and then enter the download protocol menu.
To download the Boot ROM program, enter <6> or <Ctrl + U> to access the menu for
Boot ROM downloading when the system displays: “Enter your choice(0-9):”
Bootrom update menu:
Step 4: In the download protocol menu, press <2> to select FTP protocol to download
Boot ROM and host software. Press <Enter>. The system displays the following
information:
Load File name
Switch IP address ←(This address and the server IP address must be on the same
network segment)
Server IP address ←(IP address of the PC that stores the file)
FTP User Name
FTP User Password
5-13
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software
Step 5: Input the FTP parameter values and press <Enter>. The system displays:
Are you sure to update your bootrom?Yes or No(Y/N)
Step 6: Press <Y> to start file downloading and <N> to return to the program
downloading menu. Suppose you press <Y> and then <Enter>. The system starts
program downloading and upon its completion, starts writing to Flash. After completing
the writing operation, the system displays:
Loading........................................done
Bootrom updating..........done!
Select <2>. The subsequent steps are the same as those for loading Boot ROM, except
for the program to be downloaded in prompt messages.
Run FTP server on a local PC, provided you have configured username and password
and have set the correct file directory. Suppose IP address of the PC is 10.10.110.1.
Telnet to the switch and FTP the host program to the switch.
Provided that the host program is SWITCH.app and the Boot ROM program is
SWITCH.btm, you can take these steps after telneting to the switch.
Step 1: FTP the software to the switch.
<Quidway> ftp 10.10.110.1
Trying ...
Press CTRL+K to abort
Connected.
220 WFTPD 2.0 service (by Texas Imperial Software) ready for new user
User(none):lyt
331 Give me your password, please
Password:
5-14
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software
Note:
z Power disconnection must be prevented during the loading process.
z The configurations that you just make cannot survive a reboot. Make sure you have
saved them before you have the system reboot.
z To validate the downloaded Boot ROM and host software, you must reboot the
switch.
z In case of inadequate Flash memory space, you can delete some of the program
files in Flash, those that are no longer in use for example, after completing Boot
ROM loading. Then FTP the host program to the switch.
TFTP is similar to FTP in remote software downloading. But with TFTP, the switch can
only be used as the client to download software to its Flash Memory from the TFTP
server. After that, the remaining steps are the same as remote loading using FTP.
5-15
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 6 Maintenance and Troubleshooting
You can set a password for the access to the switch via the Console port to prevent
unauthorized access.
If you lost your user password, enter the Boot Menu first:
BOOT MENU
6-1
Installation Manual
Quidway S3900 Series Ethernet Switches Chapter 6 Maintenance and Troubleshooting
Select <7> and restart the switch. After that, the system will skip the configuration file.
6-2
Installation Manual
Quidway S3900 Series Ethernet Switches Table of Contents
Table of Contents
i
Installation Manual
Quidway S3900 Series Ethernet Switches Appendix A Lightning Protection of the Switch
Caution:
Lightning arrester will not be shipped with the switch. You should purchase it by
yourself if needed.
If an outdoor AC power cord should be directly led to the switch, please serially connect
the lightning arrester for AC power (Socket Strip with Lightning Protection) before you
plug AC power cord into the switch, thus to prevent the possible damage to the switch
due to lightning strike. You can use cable clips and screws to fasten the lightning
arrester for AC power on the cabinet, workbench or the wall of equipment room.
Grounding and polarity indicator (red) :
On means that the lines are wrongly connected
(either the ground wire is not well connected, or the live and zero lines are wrongly connected).
Please check the power supply circuit.
Power switch
Normal operation indicator (green):
On means that the arrester works normally. Otherwise, it
means that the protection circuit has been damaged.
Mainboard
A-1
Installation Manual
Quidway S3900 Series Ethernet Switches Appendix A Lightning Protection of the Switch
Caution:
z Make sure that the arrester is well grounded before using the lightning arrester for
power.
z After inserting AC power cord plug of switch into the socket of lightning arrester, if
the green LED is on and the red LED does not alarm, it means that the lightning
arrester of power is running and the function of lightning protection has taken effect.
z Pay adequate attention if the red LED is on. You should correctly locate the problem,
whether it is caused because the ground wire of the arrester is not well grounded or
because the live and zero wires are connected in reverse direction. You may check
that in the following way. When the red LED is on, use a multimeter to examine
polarity at the power socket of the arrester. If it is same to that of the power socket in
the equipment room, it means that arrester is not well grounded. If it is adverse to
that of the power socket in the equipment room, it means that the power socket of
the arrester is set to the reverse polarity. In this case, you should open the power
socket of arrester to correct polarity. After that, if the red LED still alarms, it means
that the arrester is not well grounded yet.
Note:
Lightning arrester for network port is specially designed for the Ethernet port of
10/100M electrical interface (RJ-45 connector is adopted in this case).
Caution:
Lightning arrester for network port will not be provided along with the switch, and you
should purchase it by yourself if needed.
If an outdoor network cable should be led to the switch, please serially connect the
lightning arrester for network port before you plug this cable into the interface on the
switch, in case of the possibility that the switch may be damaged due to lightning strike.
I. Required tools
A-2
Installation Manual
Quidway S3900 Series Ethernet Switches Appendix A Lightning Protection of the Switch
z Multimeter
z Tilted wire cutter
Step 1: Tear the protection paper at one side of the double faced adhesive tape apart
from the tape, and stick the tape on the surface of the arrester. Tear the protection
paper at another side apart from the tape, and stick the arrester onto the chassis of the
switch. The arrester should be attached on the chassis as close to the grounding screw
as possible.
Step 2: According to the distance to the grounding screw of the switch, cut the ground
wire of the arrester, and securely tightening its ground wire to the grounding screw of
the switch.
Step 3: Use the multimeter to measure whether the ground wire of the arrester contacts
well with the grounding screw of chassis.
Step 4: According to the instruction of arrester for network port, connect the arrester
with switch by the cables (be carefully with the cable direction. Outdoor network cable
should be inserted into the arrester‘s IN end, and the cable connected to the switch
should be inserted into the arrester’s OUT end). When you do that, observe whether
the arrester indicators normally display.
Note:
The instruction of lightning arrester for network port contains the technical
specifications, installation and maintenance guide of the arrester. Please carefully read
it before installing the arrester.
A-3
Installation Manual
Quidway S3900 Series Ethernet Switches Appendix A Lightning Protection of the Switch
Fully consider the following items in the installation process, otherwise, the
performance of the lightning arrester for network port will be affected:
z Lightning arrester for network port is installed in reverse direction. In practice, the
“IN” end should be connected to the outdoor network cable and the “OUT” end to
the network port on the switch.
z Lightning arrester for the network port is not well grounded. The ground wire for
the arrester should be as short as possible, so to ensure its good contact with the
grounding screw of the switch. After the connection, use the multimeter to confirm
that.
z The lightning arrester for the network port is not installed completely. If the switch
has more than one network ports to interconnect with other devices via cables
outdoor, you should install lightning arresters for all these network ports for
protection.
A-4