Académique Documents
Professionnel Documents
Culture Documents
br/rbg
CONTAMINACAO POR CHORUME E SUA DETECCAO POR RESISTIVIDADE a a Jos Domingos Faraco Gallas1,2 , Fabio Taioli2 , Sandra Mrcia Cesrio Pereira da Silva3 , e 1 Osmar Gustavo W hl Coelho e Paulo Srgio Gomes Paim1 o e
Recebido em 23 fevereiro, 2005 / Aceito em 13 maio, 2005 Received on February 23, 2005 / Accepted on May 13, 2005
ABSTRACT. Resistivity geophysical techniques were applied closed to the Londrinas county sanitary landll, allowing the detection and mapping of leachate contamination plume. The study area lies on the Paran Basin which is locally represented by basaltic rocks of the Serra Geral Formation. a A correlation between lower resistivity values and the supposed leachate contaminations was stablished, once the electrical conduction, under natural conditions, occurs mainly in an ionic way, which are normally presented in the leachate. The main contamination ows in a general SE direction. An unexpected nding of this work was the detection of another ux direction of contamination plume to SW, which ows trough horizontal fractures or alteration surfaces of basaltic contacts. Keywords: resistivity, contamination. a RESUMO. Ensaios geofsicos de eletrorresistividade foram efetuados junto ao aterro sanitrio do Municpio de Londrina, permitindo a deteccao e mapeamento da pluma de contaminacao pelo chorume. A area de estudo situa-se na Bacia do Paran, a qual est localmente representada pelas rochas baslticas da Formacao Serra a a a Geral. Estabeleceu-se uma correlacao entre os valores mais baixos de resistividade e as possveis contaminacoes, uma vez que a conducao eltrica, em condicoes naturais, e ocorre principalmente atravs de ons, que so abundantes no chorume. e a O uxo da contaminacao principal apresenta uma direcao geral SE. Uma descoberta inesperada deste trabalho foi a identicac ao de outra direcao do uxo da pluma de contaminacao para SW, a qual ui atravs de fraturas horizontais ou superfcies de alteracao em contatos dos derrames baslticos. e a Palavras-chave: resistividade, contaminacao.
1 Universidade do Vale do Rio dos Sinos Unisinos, Av. Unisinos, 950 93022-000 So Leopoldo, RS E-mail: jgallas@euler.unisinos.com.br; Tel: (51) 590 3333 a R-1766; E-mail: ppaim@euler.unisinos.br; Tel: (51) 590 3333 R-1743; E-mail: osmar@euler.unisinos.br; Tel: (51) 590 3333 R-1738; Fax: (51) 590 8177. 2 Universidade de So Paulo USP, Rua do Lago, 562 05508-080 So Paulo, SP E-mail: jgallas@usp.br; Tel: (11) 3091 4232; E-mail: ftaioli@usp.br; a a Tel: (11) 3091 4200; Fax: (51) 3091 4207. 3 Universidade Estadual de Londrina UEL, Campus Universitrio 86051-970 Londrina, PR. E-mail: sandra@uel.br; Tel: (43) 3371 4455; Fax: (43) 3328 4440. a
52
INTRODUCAO As areas ambiental e de hidrogeologia tm tido uma crescente e demanda de aplicacao de geofsica, principalmente quanto ao mtodo da eletrorresistividade. e O estudo geofsico da area do local de disposicao de resduos s lidos do municpio de Londrina foi uma das atividades preo vistas para serem executadas no projeto Conservac ao dos re cursos hdricos subterrneos atravs da denicao de metodolo a e gia para avaliacao da poluicao causada pela m disposicao de a resduos s lidos urbanos, aprovado pelo CNPq demanda CT o Hidro01/2001, processo 550097/2002-3. Os resultados obtidos com a eletrorresistividade mostraram uma excelente correlacao entre a regio contaminada e as baixas a resistividades. Deve-se isto ao fato de que a conducao de cor rente eltrica de forma i nica ca favorecida em locais onde os e o eletr litos se enriquecem em ons, como e o caso de locais cono taminados por chorume. OBJETIVOS Os levantamentos objetivaram detectar anomalias ou assinatu` ras geofsicas correlacionveis a pluma de contaminacao no sub a solo e lencol fretico proveniente de contaminacao por chorume a oriunda do aterro sanitrio situado a montante da area estudada. a Os ensaios geofsicos de eletrorresistividade foram realizados na area a jusante do local de disposicao de resduos s lidos do o municpio de Londrina/PR, visando o estabelecer os limites late rais da pluma de contaminacao e tambm uma avaliacao de sua e penetracao em profundidade. GEOLOGIA DA AREA O Municpio de Londrina/PR situa-se na Bacia do Paran e, local a mente, na area estudada, aoram rochas baslticas da Formacao a Serra Geral. A Bacia Sedimentar do Paran constitui a provncia estrutua ral da Plataforma Sul Americana, onde ocorreu a mais extensa manifestacao vulcnica de natureza continental na superfcie ter a restre. Suas ssuras, fraturas e falhas de distenso permitiram a asa censo de enormes volumes de magma basltico. A intensidade a a deste vulcanismo pode ser avaliada pelas dimens es de diques o que podem atingir mais de 100 km de extenso e at centenas de a e metros de espessura (Almeida et al., 1976). O tectonismo responsvel pelo fraturamento da crosta e asa censo de grandes volumes de magma, na era mesoz ica da Bacia a o ` do Paran, est intimamente associado a fragmentacao do antigo a a
mega-continente Gondwana. Especicamente, na regio de Londrina, estima-se que a esa pessura dos derrames baslticos situe-se entre 600 e 800 m. a CONTAMINACOES E RESISTIVIDADE A conducao da corrente eltrica na natureza processa-se princi e palmente da forma i nica, sendo este modo de conducao o mais o signicativo nos estudos por eletrorresistividade. As pseudo-secoes e secoes modeladas de resistividade evi denciam claramente a relacao deste parmetro com a pluma de a contaminacao ao longo dos pers ensaiados. As contaminacoes em subsuperfcie so os locais em que a ` as resistividades apresentam-se mais baixas porque, devido a presenca dos contaminantes, estes locais tm aumentado con e sideravelmente seu conte do i nico. Desta forma, a a corrente u o se propagar com maior facilidade, resultando em zonas menos a ` resistivas. Este comportamento obedece a lei de Ohm, J = E (1)
onde J e a densidade de corrente, E o campo eltrico e a cone dutividade do meio. Uma vez que a grande maioria das rochas e o subsolo em geral so maus condutores, suas resistividades deveriam ser extrea mamente altas no fosse pelo fato que usualmente os poros esto a a preenchidos por uidos, principalmente agua. Em vista disso, assumem um comportamento de condutores eletrolticos (Telford et al., 1990), cuja resistividade aparente pode ser denida como na conhecida e simples equacao 2 adiante, derivada da Lei de Ohm. A resistividade e obtida pela emisso de uma corrente I , emia tida atravs de dois eletrodos A e B e a diferenca de potencial e V , usualmente medida atravs dos eletrodos de potencial die tos M e N . A partir destes parmetros e possvel obter-se a rea e o sistividade aparente a . Em um terreno homogneo e isotr pico esta resistividade ser constante para quaisquer disposicoes de a eletrodos que sejam empregadas nas medicoes. a = K K = V I
1 AN
(2) (3)
2
1 AM
1 BM
1 BN
onde K e um fator geomtrico que depende das distncias entre e a os eletrodos de corrente ( A e B) e de potencial (M e N ), I e a corrente gerada entre os eletrodos de corrente e V a diferenca de potencial estabelecida entre M e N . As resistividades tambm variam com a mobilidade, e concentracao e grau de dissolucao dos ons, sendo que o grau de
Revista Brasileira de Geofsica, Vol. 23(1), 2005
JOSE D.F. GALLAS, FABIO TAIOLI, SANDRA M.C.P. DA SILVA, OSMAR G.W. COELHO e PAULO S.G. PAIM
53
dissolucao depende da constante dieltrica da solucao. Compa e ` rativamente a conducao ohmica (eletr nica), a conducao i nica o o no e to somente mais lenta, mas representa tambm um transa a e porte de material (Keller & Frischknecht, 1977). A resistividade de uma rocha decresce com o aumento de seu conte do de agua e tambm com o volume dissolvido de cloreu e tos, sulfatos (sais em geral) e presenca de outros minerais. Alm e disto, para haver boa conducao eltrica os poros precisam estar e interligados e preenchidos com agua. No sentido de correlacionar-se resistividade com conte do u de agua, foi observado que a resistividade varia aproximadamente com o inverso do quadrado da porosidade, quando a rocha est a saturada com agua. Esta observacao levou ao uso difundido de uma relacao emprica de resistividade e porosidade (Archie, 1942), conhecida como Lei de Archie. = aw m (4)
2 e 4 e a simulacao 3-D referente ao nvel 4. PROCESSAMENTO E ANALISE DOS RESULTADOS Medidas de resistividade normalmente so apresentadas e ina terpoladas (contornos de isovalores) sob a forma de pseudosecoes (Hallof, 1957) que do uma representacao visual do com a portamento das resistividades em subsuperfcie. No entanto, as formas dos contornos no dependem exclusivamente das a distribuicoes de resistividades medidas, mas tambm da geo e metria da conguracao de eletrodos empregada. Mesmo cor pos de formas geomtricas simples (retangulares, p. ex.), apree sentam pseudo-secoes completamente diferentes, conforme o ar ranjo empregado. Nesse sentido, para obter-se uma secao de resistividade mais precisa, torna-se necessria a aplicacao de processos de inverso a a nos dados que, em tese, conduz a uma aproximacao razovel de a modelos para diversas estruturas geol gicas. o As secoes modeladas so resultantes de um processo au a tomtico de inverso bi-dimensional (2-D). Os processos de ina a verso de dados de resistividade buscam estabelecer um modelo a da provvel distribuicao real dos valores de resistividade em suba superfcie. As eventuais distorcoes nas pseudo-secoes inerentes aos arranjos de eletrodos so, teoricamente, eliminadas por este a procedimento. Os dados obtidos foram processados atravs dos prograe mas RES2DINV e Surfer 8, da ABEM Instruments (1998) e Gol den Software, respectivamente. O Surfer 8 e um programa para interpolacao de dados, enquanto que o RES2DINV e um programa de inverso para resistividade e polarizacao induzida (IP). a Os resultados da inverso pelo RES2DINV foram exportados a na forma de arquivos XYZ e interpolados pelo Surfer 8 (krigagem), visando uma apresentacao de melhor qualidade dos mesmos. O RES2DINV adota uma tcnica rpida e eciente para ine a verso de dados de resistividade que foi desenvolvida por Loke a & Barker (1996a, 1996b) e deGroot-Hedlin & Constable (1990), baseia-se no mtodo dos mnimos quadrados e suavizacao rese tringida (smoothness-constrained). Teoricamente, produz um modelo de subsuperfcie 2-D isento das distorcoes na pseudo secao de resistividade aparente originadas pela geometria do ar ranjo eletr dico usado. o INTERPRETACAO As Figuras 4 e 5, trazem as pseudo-secoes de resistividade apa rente e secoes modeladas de resistividade dos pers C e D. Ambas as formas de apresentacao dos dados mostram contras
onde e a resistividade total, w a resistividade da agua dos poros, e a porosidade expressa como uma fracao por unidade de volume e a e m referem-se ao tipo de porosidade e grau de cimentacao, respectivamente. TECNICAS UTILIZADAS E ENSAIOS EFETUADOS Os levantamentos de eletrorresistividade executados consistiram de seis pers Linhas A, B, C, D, E e F com o arranjo dipolodipolo com aberturas AB=MN=20m e cinco nveis te ricos de o investigacao (n1 = 20 m; n2 = 30 m; n3 = 40 m; n4 = 50 m e n5 = 60 m), respectivamente (Hallof, 1957). A opcao pelo dispo sitivo dipolo-dipolo deveu-se aos objetivos a serem alcancados pela geofsica, quais sejam, a determinacao dos limites da pluma de contaminacao do chorume, bem como indicacoes do compor tamento da poluicao com a profundidade. A separacao entre pers foi determinada no campo atravs e de posicionamento com GPS e foram praticamente paralelos entre si. As posicoes das linhas podem ser vistas na Figura 1 que contm o mapa de resistividade. Os pers foram efetuados pere ` pendicularmente a drenagem existente visando interceptar a zona contaminada. Tambm so apresentadas as secoes modeladas atravs e a e de processos de inverso de dados, por meio do programa a RES2DINV da ABEM Instruments (ABEM, 1998, Loke & Barker, 1995), cujas profundidades de investigacao fundamentam-se em Edwards (1977) e so aproximadamente a metade daquelas proa postas por Hallof (op. cit.). Esto sendo apresentados neste trabalho os resultados dos a pers C e D e o mapas de resistividade dos nveis de investigacao
Brazilian Journal of Geophysics, Vol. 23(1), 2005
54
LIN H A B
42 28 27 32 47 62 77 62 55
LINH A A
29 VA LOR MEDIDO DE + RESISTIVIDADE APARENTE E SEU PONTO DE PLOTAGEM 7418750 CONTORNO INTERPRETADO DE REA CONTA MINADA LIMITES DA CONTAMINAO PELA INVERS O DE DADOS
LIN HA B
61 88 144 204 224
7418700
7418650
IO M UN I C I PA L
32
180 150
7418600
IT R
SA N
7418550
120
LIN HA C
90 60 30 0
RRO
7418500
11 11 9 25 53 11 19 8
7418450
7418400
A TE
LIN HA D
18 16 13 32
19
9 14 28 14
43
32 17 24 19 27 27 42 17 43 75 101 49 57 30 28 29 18 17 19 14
7418350
18
11
88 35 35
7418300
23 43
16
79 18 14 12 14 10 11 19 20 17 19 15 20 39
7418250
36
161
30 57
7418200
116
LINHA F
7418150
LINHA E
31
23
489150
489 200
489250
489300
489350
489400
489450
489500
48 9550
tes de resistividade bastante ntidos. E possvel estabelecer-se uma correlacao entre as zonas de resistividades mais baixas e a contaminacao por chorume. Esta associacao e a normalmente esperada, uma vez que o chorume e riqussimo em ons e a
conducao da corrente eltrica em condicoes como as existentes e na natureza d-se principalmente de forma i nica. Desta forma, os a o substratos com um eletr lito rico em ons permitiro que a coro a rente eltrica se propague com maior facilidade, resultando em e
JOSE D.F. GALLAS, FABIO TAIOLI, SANDRA M.C.P. DA SILVA, OSMAR G.W. COELHO e PAULO S.G. PAIM
55
LIN HA A
LINHA B
130
110
7418650
90
96
16 16 10 15 11 35 10 10 12 14 40 16 8 10 23 23 75 25 42 33 38 89 90 72 89
7418600
70
7418550
50
LIN HA C
30
7418500
LINH A D
10
15
7418450
11
36 29
24
7418400
22 35 26 28
28
16 20 54 38 25 29
60
25 27 32 40 35 30 31 34 23 25 41 24 27 27 28 23
7418350
18 24 40 51
23
50 35 64 36 24 22 17 38 20 36 41 32 32 58 59
7418300
7418250
50
28
7418200
LINHA F
7418150
LINH A E
32
489150
489200
489250
489300
4 89350
489400
489 450
489500
489550
anomalias de baixas resistividades. Por outro lado, regi es de basaltos, como e o caso da area o estudada, costumam apresentar solos e nveis superciais da ro cha alterada/fraturada com baixas resistividades. Mesmo assim, em tal situacao, a resistividade decrescer como um todo e o que a
se busca so os contrastes relativos de resistividade entre o subsa trato contaminado e o no contaminado. a Outro fato a ser lembrado e que a area em questo situa-se a em uma drenagem para onde uem as aguas de subsuperfcie, o que tambm ocasiona uma queda nos padr es de resistividade. e o
56
Conforme visto nas Figuras 4 e 5, so assinaladas nas mesa mas, atravs de uma barra hachurada, as projecoes na superfcie e ` das regi es consideradas associadas a contaminacao, assim ino terpretadas de acordo com as caractersticas apresentadas pelas resistividades baixas nestas associacoes com chorume. Este representado nas secoes modeladas e pseudo-secoes padro e a atravs da cor avermelhada. e De forma a ter-se uma visualizacao em planta da extenso da a regio interpretada como atingida pelo chorume, foram elaboraa dos mapas de resistividade, gerados a partir dos dados do dipolodipolo e apresentados nas Figuras 1 e 2. Com o mesmo objetivo, foi tambm elaborada uma simulacao tri-dimensional do mapa e de resistividade aparente do nvel 4 e est sendo apresentada na a Figura 3. O mapa apresentado na Figura 1 contm os dados de ree sistividade do nvel 2 (cerca de 14m, segundo Edwards, 1977) das pseudo-secoes de resistividade aparente. Verica-se uma distribuicao dos valores mais baixos de resistividade que origina se a montante da area, abrangendo grande parte da linha A, situada mais pr xima do aterro, e prolonga-se at a linha mais a o e jusante linha F, estreitando-se nesta direcao. A linha F situa-se na porcao da drenagem onde j h agua aorante, nascente do a a riacho. Os limites da area interpretada como contaminada pelo chorume foram assinalados com uma linha tracejada vermelha. Igualmente foi assinalado um polgono com linha tracejada em azul na area geometricamente delimitada pelos dados de resistividade submetidos aos processos de inverso. Constata-se que a a interpretacao qualitativa visual e a fornecida pela inverso dos a dados apresenta uma excelente correlacao. Para avaliar-se semi-quantitativamente o comportamento da contaminacao em um nvel mais profundo, foi elaborado um mapa de resistividade com os valores referentes ao nvel 4 de investigacao (cerca de 24 m, segundo Edwards, 1977). Foi de limitada neste mapa com uma linha tracejada em vermelho a interpretacao da area contaminada neste nvel mais profundo. Observa-se que a pluma de contaminacao apresenta-se um pouco mais estreita que no mapa anterior. Foi assinalado por meio de setas neste a possvel existncia de uma outra direcao do uxo de e contaminacao, conforme descrito a seguir. As secoes modeladas e pseudo-secoes indicam que a contaminacao, alm da direcao SE, deve estar se propagando em e profundidade tambm na direcao SW, conforme pode ser visto e e assinalado nas secoes modeladas, principalmente das linhas C, D, E e F. Interpreta-se que esta percolacao acontece ao longo de fratura(s) horizontalizadas ou ao longo da superfcie de alteracao
que comumente ocorre entre dois derrames baslticos. a Dados de 12 sondagens efetuadas na area estudada mos tram que a profundidade do topo rochoso e rasa e situa-se entre 4 e 11m de profundidade, o que d sustentabilidade a esta a interpretacao. Uma vez que a espessura dos derrames baslticos a bastante varivel (poucos a vrios metros), ento e perfeitamente e a a a razovel a interpretacao de um contato entre derrames na profuna didade indicada nas secoes modeladas de resistividade (guras 4 e 5) onde ocorre a inltracao SW interpretada.
CONCLUSOES E RECOMENDACOES De acordo com o objetivo proposto, considera-se que os ensaios geofsicos realizados na area do aterro sanitrio do municpio de a Londrina atingiram plenamente o mesmo, qual seja o de mapear a area atingida pela pluma de contaminacao do chorume. O reco brimento da area estudada foi pleno, uma vez que os trabalhos se realizaram desde um perl (linha A) situado imediatamente adja cente ao aterro e estendeu-se at onde comeca a surgir agua na e drenagem (entre linhas E e F). O mtodo da eletrorresistividade e uma tcnica geofsica de e e prospeccao indireta, devendo os resultados e interpretacoes aqui apresentados serem usados para a otimizacao das investigacoes diretas subseq entes, tais como sondagens/pocos de monitorau mento, aberturas de valas, trincheiras etc. Uma vez que a maior conducao eltrica em condicoes natu e rais d-se principalmente atravs de ons, nos quais o chorume e a e bastante rico, interpretou-se uma correlacao entre os valores me didos de resistividades mais baixas e as possveis contaminacoes por chorume. De acordo com estes critrios, recomenda-se como mee todologia de deteccao direta da area atingida pela pluma de contaminacao, sondagens/pocos de monitoramento na area in dicada como contaminada na gura 1 mapa de resistividade do nvel 2. Tambm so recomendadas sondagens/pocos de monito e a ` ramento externamente a area contaminada a ttulo de conrmar-se as zonas no atingidas. a Complementarmente, podem ser realizados testes/ensaios de permeabilidade nas sondagens futuras, possibilitando uma estimativa de estabelecer-se a velocidade dos uxos subterrneos na a area estudada. O uxo da contaminacao principal apresenta uma direcao geral SE. Uma descoberta inesperada deste trabalho foi a identicacao de outra direcao do uxo da pluma de contaminacao para SW, a qual ui atravs de fratura(s) horizontal(is) ou sue perfcies de alteracao em contatos dos derrames baslticos. a
Revista Brasileira de Geofsica, Vol. 23(1), 2005
JOSE D.F. GALLAS, FABIO TAIOLI, SANDRA M.C.P. DA SILVA, OSMAR G.W. COELHO e PAULO S.G. PAIM
57
500
300
200
125
75
40
25
15
10
PSEU DO-SE O D E R ESISTIVID AD E A PAR ENTE 0m 20m 40m 60m 80m 100m 120m 140m 160m 180m 200m 220m 240m 260m 280m 300m 320m 340m
292 142
247 106 74 89
233 96 68 42 52
317 40 26 33 24
76 13 22 36 33
20 15 18 29 40
8 10 19 23 22
7 9 12 16 24
14 14 12 20 18
17 17 24 27 22
34 19 21 29 17
50 29 27 27 34
70 42 29 30 22
119 57 30
134
260
220
180
140
100
60
20
LEGENDA
PROJEO NA SUPERFCIE DE ANOMALIA DE BAIXA RESISTIVIDADE - CORRELACIONVEL CONTAMINAES POR CHORUME 32
40m
787 71 81 140
6 0m
913 107 43 91 329
80m
366 163 22 53 317
10 0m
237 52 15 58 275
120m
52 8 17 78 170
140m
14 5 17 48 74
160m
200m
17 9 16 35 60
220m
35 24 19 46 115
240m
106 21 20 43 103
260m
229 24 23 32 39
280m
243 40 32 26
300m
311 48 25
320m
340m
-10m
84 60
-30m
-50m 900 800 700 600 500 400 300 200 100
58
Esta interpretacao sustenta-se no fato de que as espessuras do manto de alteracao na area onde os ensaios foram efetuados oscila entre 4 e 11m, de acordo com os dados de 12 sondagens realizadas no local. Sabendo-se que os derrames baslticos tm a e espessuras muito variveis, ento pode-se admitir uma interface a a entre derrames na profundidade indicada para a inltracao SW, conforme assinalado nas secoes modeladas de resistividade. A conrmacao desta hip tese depende de execucao de sondagens o locadas baseando-se nas indicacos das guras 2 (mapa do nvel 4) e nas secoes modeladas de resistividade (Figuras 4 e 5).
REFERENCIAS
ABEM INSTRUMENTS. 1998. Geoelectrical Imaging 2D & 3D RES2DINV, ver. 3.3 for Windows 3.1, 95 and NT. Rapid 2D Resistivity & IP inversion using the least-squares method. By M. H. Loke. ABEM Instruments, P.O. Box 20086, S-161 02 Bromma, Sweden. Paginacao irregular. ALMEIDA FFM, HASUI Y & NEVES BBB. 1976. The upper precambrian of South America. So Paulo, Instituto de Geocincias, Universidade de a e So Paulo, So Paulo. Boletim 7, p. 4580. a a ARCHIE GE. 1942. The electrical resistivity log as an aid in determining some reservoir characteristics. Trans. A.I.M.E. 146: 5464. deGROOT-HEDLIN C & CONSTABLE S. 1990. Occams inversion to generate smooth, two-dimensional models form magnetotelluric data. Geophysics, 55(12): 16131624. EDWARDS LS. 1977. A modied pseudo-section for resistivity and induced-polarization. Geophysics, 3: 7895. HALLOF PG. 1957. On the interpretation of resistivity and induced polarization measurements: Cambridge, MIT, Ph. D. thesis. KELLER GV & FRISCHKNECHT FC. 1977. Electrical methods in geophysical prospecting. Oxford: Pergamon Press, 517 p.
AGRADECIMENTOS Este trabalho foi realizado gracas ao apoio do CNPq, via Pro jeto Conservacao dos recursos hdricos subterrneos atravs a e da denicao de metodologia para avaliacao da poluicao causada pela m disposicao de resduos s lidos urbanos, aprovado pelo a o CNPq demanda CT-Hidro01/2001, processo 550097/20023. Agradece-se tambm aos revisores, que contriburam para o e aperfeicoamento da apresentacao nal deste trabalho.
JOSE D.F. GALLAS, FABIO TAIOLI, SANDRA M.C.P. DA SILVA, OSMAR G.W. COELHO e PAULO S.G. PAIM
59
LOKE MH & BARKER RD. 1995. Least-squares deconvolution of apparent resistivity pseudosections. Geophysics, 60(6): 16821690. LOKE MH & BARKER RD. 1996a. Rapid least-squares inversion of apparent resistivity pseudosections by a quasi-Newton method. Geophysical Prospecting, 44: 131152 . LOKE MH & BARKER RD. 1996b. Practical techniques for 3D resistivity
surveys and data inversion. Geophysical Prospecting, 44: 499523. ORELLANA E. 1972. Prospeccion geoeletrica en corriente continua. Madrid: Paraninfo, 523 p. TELFORD WM, GELDART LP & SHERIFF RE. 1990. Applied geophysics. Second Edition. Cambridge: Cambridge University Press, 770 p.