Vous êtes sur la page 1sur 3

Design of Regeneration

Composition
Mwt
Tci (K)
C1
0.898937
16
C2
4.40E-02
30
C3
2.53E-02
44
iC4
3.48E-03
58
nC4
7.47E-03
58
iC5
1.20E-03
72
nC5
1.16E-03
72
C6
1.53E-03
86
C7
1.91E-03
100
N2
1.50E-02
28

Pci(Kpa abs)
190.56
350.33
369.77
407.82
425.12
460.4
469.7
507.5
540.13
126.19

yi*Tci
4599
4872
4244
3640
3798
3381
3370
3012
2736
3396

171.3013986
15.4011674
9.353660381
1.419393581
3.176674022
0.554142427
0.546491474
0.778811434
1.029335005
1.898545637
205.45962

Composition
A
B
C1
0.898937
19.251
C2
4.40E-02
5.409
C3
2.53E-02
-4.224
iC4
3.48E-03
-1.39
nC4
7.47E-03
9.487
iC5
1.20E-03
-9.525
nC5
1.16E-03
-3.626
C6
1.53E-03
-4.413
C7
1.91E-03
-5.146
N2
1.50E-02
31.15
MIX
Cp

1.79E+01
40.11258

Flow rate of regen gas

His
3.588203 Kj/Kg
Power
32.46066 Kw
Power after efficiency

Discharge temperature

5.21E-02
1.78E-01
3.06E-01
3.85E-01
3.31E-01
5.07E-01
4.87E-01
5.82E-01
6.76E-01
-1.36E-02

1.20E-05
-6.94E-05
-1.59E-04
-1.85E-04
-1.11E-04
-2.73E-04
-2.58E-04
-3.12E-04
-3.65E-04
2.68E-05

-1.13E-08
8.71E-09
3.21E-08
2.90E-08
-2.82E-09
5.72E-08
5.30E-08
6.49E-08
7.66E-08
-1.17E-08

6.94E-02

8.32E-07
31.79857887 K

-8.70E-09

Cv

32567.38808 kg/hr
1773.400479 Kgmole/hr

43.28088274 Kw

324.9620747 K
51.96207472 C

gn of Regeneration Gas Compressor


yi*Pci
yi*Mwt
4134.210391
14.38298897
214.1823069
1.31885657
107.3557472
1.113019057
12.66880642
0.201865597
28.38024072
0.433400201
4.069408225
0.08665998
3.920962889
0.083771314
4.62222668
0.131975928
5.214042126
0.190571715
51.09327984
0.421263791
4565.717412

18.36437312

T
49.44444444

Pr
Tr
M.wt avg
Z ( from GPSA)

121 F
322.4444444 K

1.584792407
1.5693811
18.36437312
0.87
56.97355855
0.0115
0.013915

gm/gmole
Kg/m3
cp
cp

1.261458225
P discharge

1080 psi
7442.44898 Kpa

CF

1050 psi abs


7235.714 Kpa abs

1.21

Vous aimerez peut-être aussi