Radiant Panel Heater

Operating Instructions
Model HCC10E2 /HCC15E2

FOR PERSONAL INDOOR USE ONLY


BEFORE USING THIS PRODUCT, READ, UNDERSTAND, AND FOLLOW THESE INSTRUCTIONS. Save this booklet for future reference

To reduce the risk of fire, electric shock, or personal injury, read all the instructions before using this heater.

WARNING!

IMPORTANT SAFEGUARDS
READ ALL INSTRUCTIONS BEFORE USING.
WARNING: In order to avoid overheating, do not cover the heater. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard This product was designed to be installed in residence and indoor use only. Please do not use the product for any other purpose. The electrical installation must be carried out by a qualified electrician in accordance with the local regulations; The heater is fitted with a length of flexible cable for connection to the fixed wiring of the premises through a suitable connection box positioned adjacent to the heater; If the heater is installed in room containing a bath or shower, it must be so installed that switches or controls cannot be touches by a person using a bath or shower; The supply circuit to the heater must incorporate a double pole isolating switch having a contact separation of at least 3mm; If a pilot or piloted heater is protected by a 30mA differential (e.g. bathroom) the pilot wires power supply. Do not cover the heater. Never cover or obstruct in any way the heat outlet slots at the top of the heater or the air inlet slots in the base of the heater; For your safety, this heater is fitted with a thermal cut-out. In the event that the product overheats for some reasons, the cut-out prevents excessive temperatures on the product by cutting the power to the heater;

KNOW YOUR WALL HEATER

Front

Back

WHERE TO INSTALL THE WALL HEATER? This heater is designed to be installed and indoor use only. Do not locate the heater below a fixed socket outlet or connection box. Comply with the minimum clearance distances as indicated in Fig. 1. In humid areas such as bathrooms and kitchens, the connection box must be installed at least 25cm above the floor. Do not install the heater 1) In a draught likely to affect the control setting 2) Under a fixed mains power socket; 3) In volume 1 of bathrooms; 4) In volume 2 if the controls can be operated by a person using the shower or bath;
FIG. 1

HOW TO INSTALL THE WALL HEATER?

STEP 1

STEP 2

STEP 3

The wall brackets supplied with the heater must be used. The heater should be positioned observing the minimum clearances stated around the heater see Fig. 1 First remove the wall bracket from the rear housing. Unscrew the 2 screws located on the top of the 2 vertical bars of the wall bracket (See Step1). Then pull out the top bar by pressing firmly both upper parts slotted into the rear housing (see fig 2) Slide down the wall bracket in order to remove it from the rear housing. (See fig 3) Fix the wall bracket securely to the wall through the 4 screw holes provided. Raise the heater to upright position; Present the heater and engage 2 slots of the bottom parts of the wall brackets in the wall heaters rear enclosure then pull up the heater. Then engage 2 slots of the upper parts of the wall bracket and tighten the 2 screws in order to lock the device. ELECTRICAL CONNECTION The heater must be powered with 220-240V 50Hz This heater is a double insulation class electrical appliance. DO NOT connect the earth or wiring the internal wire. This heater must be installed by a qualified electrician. WARNING: The heater and the pilot wire must NOT be connected the Earth. OPERATION LED Screen Control panel

Before the user choose the control panel, , Push the power switch to ON position the LED screen will display the room temperature that means the heater is ready. You can turn on the heater by the control panel .

ON/OFF button: Press the ON/OFF button once to turn on the heater and the
LO LED lamp is on .At this mode, the heating power is LO Position. If Press ON/OFF button once more to turn off the heater, the heater will be stand by and LED screen display the room temperatures.

MODE Button:There are three modes, Lo,HI, and Auto, if the user choose Auto
mode, they can choose the TEMP function and choose their availble and confortable temp.

TEMP Button: The temperature range is 5C ~ 35C. The maximum setting is


around 35 which means the heater will normally remain on continuously. The minimum setting is around 5 ; When the ambient temperature reaches the set temperature, heat setting will be turned off automatically.

When ambient temperature is lower than the set temperature, heating setting will be turned on again.

Timer Button: When the heater is in use, you can set the timer for turning off the
unit. Press the timer button once, the LED screen will display the default timer setting value or the last time setting value. The default value is 0.0hr. To set the timer, keep pressing TIMER button to set the timer between 0.5 and 8 hours in 0.5hr interval. The timer will be set within 5 sec once you finish pressing the buttons. The timer setting value will stop flashing and display on the LED. When the time runs out, the heater will turn off automatically.

See attached remote controller pictures .

MAINTENANCE

2 3

Before you clean the appliance, switch the heater off and wait until the heater has cooled down. Use a damp cloth to wipe off the fan heater housing Clean the upper and lower grilles of the unit periodically Do not use water, detergents, abrasive cleaning liquids or chemical agents (Alcohol, Gasoline etc) to clean the appliance.

Remote controller: Push the power switch to ON position

the LED screen will display the room temperature that means the heater is ready. You can turn on the heater by the remote controller, and you can operate the all function as above referred function.

SPECIFICATIONS
Product dimension LXWXH (in mm)
592*437*119

Note:

There may be a trace of smoke or odour when unit is first operated. Do not be alarmed. This indicates that a drop of oil fell on the heating coil during the manufacturing process. It will quickly evaporate and should not re-occur.

This product contains recyclable materials. Do not dispose this product as unsorted municipal waste. Please contact your local municipality for the nearest collection point.

HCC15E2

230V-50Hz

1500W

812*437*119

Double insulation CLASS

HCC10E2

230V-50Hz

1000W

Model

Voltage & Frequency

Power (in Watt

Class
Double insulation CLASS

Water proof class

IP24