Vous êtes sur la page 1sur 4

BUILD-01 (TELCON) CONNECTION DESIGN FOR FRAME-1 Design momoment resisting Connection

( Ref :- Four Tension Bolt End Plate Design Proceedure of AISC (ASD) - (9th Edition)) ( Ref :- Page no 4-118 of AISC ) Input Data Connection Location :Condition :Moment ( M ) = End Shear ( V ) = Axial Tension ( H ) = NODE-135 DL+WLN1 H -55 KNm -41 KN 0 M D V

No(n) of Bolts / flange = Bolt Details :Fy(Bolt) = Diameter (db) of Bolt = Gross Area (Ag) of Bolt = Net Area (An) of Bolt = Beam Details:Depth (D) = Width (bfb) of Flange = Thickness (tf) of Flange = Thickness (tw ) of web = End Plate Details :Max Thickness = Fy = Analysis :End Plate Width = bp = bf + 20 mm = Flange Force (Ff) = M / (D-tf) = Tensile Force ( T ) per bolt = Ff /n + H/(2n) = Shear Force per bolt = V/(2n) =

640 mpa 20 mm 314.16 mm2 241.9032 mm2

( Grade : 8.8 Class bolts)

250 mm 150 mm 5 mm 4 mm

20 mm 345 mpa UPTO 20mm THIKNESS 345 Mpa

150 + 20 =

170 mm -225.41 KN -56.35 KN

-55 x 1000 / ( 250 - 5 ) =

-225.41 / 4 + 0 / ( 2 x 4 ) = -41 /( 2 x 4 ) = -5.125 KN

Checking Bolt Capacity as per IS : 800 Refer :- Clause no 8.9.4 of IS : 800 Actual Tensile Stress ( sft.cal ) in bolt = Actual Shear Stress ( tvf.cal) in bolt = Combined Shear & Tension Interaction Check ( Ref :- Clause no :- 8.9.4.5) Interaction Check = (sft.cal/sft + tvf.cal/tvf)) = -0.89994 < 1.4 x 1.33 (O.K.) -232.955 mpa -16.3133 mpa < 286 x 1.33 (O.K.) < 191 x 1.33 (O.K.)

End Plate Thickness :Pe = Effective bolt distance to be used to compute bending moment in end plate Pe = Pf - (db/4)-0.707w Where Pf = Distance of bolt to nearer surface of tension flange = w = weld size = Pe = 50 - ( 20 / 4 ) - 0.707 x 8 = 8 mm 39.344 mm 50 mm

Me = Moment to be resisted by end plate Me =a m x Ff x Pe /4 Where am = Ca x Cb x (Af / Aw) 1/3 ( Pe / db )1/4 Ca = Cb = ( bfb/bp) 0.5 = 1.11 0.939336 750 mm2 960 mm2 for fy = 345 mpa

Af ( Tension Flange Area) = bfb x tf = Aw ( Area of Beam Web ) = ( D- 2 x tf )x tw = Therefore am = Me = 1.137379396 -2521719.286 Nmm

Required Plate Thickness tp = ( 6 x Me / ( Fb x bp )) 0.5 Fb = Allowable Bending Stress = 0.75 x Fy x 1.33 = tp = Use 16.08175845 mm 16 mm Thk End Plate 344.1375 mpa

HENCE USE 16 mm THICK PLATE & 20 mm DIA. BOLTS

BUILD-01 (TELCON) CONNECTION DESIGN FOR FRAME-1 Design momoment resisting Connection
( Ref :- Four Tension Bolt End Plate Design Proceedure of AISC (ASD) - (9th Edition)) ( Ref :- Page no 4-118 of AISC ) Input Data Connection Location :Condition :Moment ( M ) = End Shear ( V ) = Axial Tension ( H ) = NODE-135 1.3DL+CL+EQX H 50.83 KNm -42.27 KN -0.81 M D V

No(n) of Bolts / flange = Bolt Details :Fy(Bolt) = Diameter (db) of Bolt = Gross Area (Ag) of Bolt = Net Area (An) of Bolt = Beam Details:Depth (D) = Width (bfb) of Flange = Thickness (tf) of Flange = Thickness (tw ) of web = End Plate Details :Max Thickness = Fy = Analysis :End Plate Width = bp = bf + 20 mm = Flange Force (Ff) = M / (D-tf) = Tensile Force ( T ) per bolt = Ff /n + H/(2n) = Shear Force per bolt = V/(2n) =

640 mpa 20 mm 314.16 mm2 251.328 mm2

( Grade : 8.8 Class bolts)

400 mm 250 mm 8 mm 4 mm

20 mm 345 mpa UPTO 20mm THIKNESS 345 Mpa

250 + 20 =

270 mm 129.01 KN 32.15 KN

50.83 x 1000 / ( 400 - 8 ) =

129.01 / 4 + -0.81 / ( 2 x 4 ) = -42.27 /( 2 x 4 ) = -5.28375 KN

Checking Bolt Capacity as per IS : 800 Refer :- Clause no 8.9.4 of IS : 800 Actual Tensile Stress ( sft.cal ) in bolt = Actual Shear Stress ( tvf.cal) in bolt = Combined Shear & Tension Interaction Check ( Ref :- Clause no :- 8.9.4.5) Interaction Check = (sft.cal/sft + tvf.cal/tvf)) = 0.359237 < 1.4 (O.K.) 127.9256 mpa -16.8187 mpa < 286 (O.K.) < 191 (O.K.)

End Plate Thickness :Pe = Effective bolt distance to be used to compute bending moment in end plate Pe = Pf - (db/4)-0.707w Where Pf = Distance of bolt to nearer surface of tension flange = w = weld size = Pe = 8 mm 39.344 mm 50 mm

50 - ( 20 / 4 ) - 0.707 x 8 =

Me = Moment to be resisted by end plate Me =a m x Ff x Pe /4 Where am = Ca x Cb x (Af / Aw) 1/3 ( Pe / db )1/4 Ca = Cb = ( bfb/bp) 0.5 = 1.11 0.96225 2000 mm2 1536 mm2 for fy = 345 mpa

Af ( Tension Flange Area) = bfb x tf = Aw ( Area of Beam Web ) = ( D- 2 x tf )x tw = Therefore am = Me = 1.381172567 1752630.445 Nmm

Required Plate Thickness tp = ( 6 x Me / ( Fb x bp )) 0.5 Fb = Allowable Bending Stress = 0.75 x Fy = tp = Use 12.26870544 mm 16 mm Thk End Plate 258.75 mpa

HENCE USE 16 mm THICK PLATE & 20 mm DIA. BOLTS