Vous êtes sur la page 1sur 6

item_code

description 1 Earth work excavation in soil, clay, sand, shedu soil soft murrum including shoring stoutting barricading danger lighting bailing out water wherever necessary with stacking the materials as directed all lead and lift of 1.5 m etc., complete.and as directed by the Engineerin-charge. 2 Providing and laying granite or trap or basalt jelly cement concrete 40 mm ( cc M10) and down size jelly for foundation laid in 15 cm thick layers and well compacted including machine mixing, curing etc., complete as per specification.and as directed by the Engineerin-charge. 3 Providing and laying granite or trap or basalt jelly cement concrete M10 proportion using 20 mm and down size jelly including machine mixing, laying, tamping, curing and plastering for exposed faces with cement mortar 1:4 proportion and with necessary centering, form work etc., complete.and as directed by the Engineer-in-charge. 4 Rcc Hume pipe circular pump house manufacturing and supplying precast spun Rcc conical roof as per specifications and drawings. The Rcc Hume pipe pump house should have in internal diameter of 1200 mm and a height of 2.5 m with wall thickness of 65 mm. the Rcc Hume pipe pump house should consists of 12 rods or 6 mm dia bound at 50 mm pitch (CC) with 2 extra turns at both ends. the reinforcement should be placed in the wall giving adequate cover for concrete at both sides throughout its length. The cement concrete should have cemen content of 360 Kg per cum of concrete. the concrete should be compacted at adequate speed such that resultant conceret is dense and homogenous. The door frame should be ISA 35 x 35 x 5 mm welded to the reinforcement cage. The doors size should be of 600 mm width and 1800 mm height. The shutter should be of 18 gauge MS sheet welded on a frame of ISA 25 x 25 x 150 mm at top of the shutter for ventilation purpose. Th e opening is to be of a frame ISA mesh as shown in drawing. The doors should be painted on either side with 2 coats of anti-corrosive paints with a primer coat of red-oxide paint. The roof is to be made of precast Rcc. slab of 1600 mm diameter rods and 50 mm thick. The reinforcement should be of 6 mm dia adequate cover at the top and bottom sides. The concrete should have a cement content of 400 Kg per cum of concrete be of soils 12 mm and below and good river sand should be used, finished smooth both sides. and as directed by the Engineer-in-charge. 5 Providing and installing at site of work 110mm dia 6 ksc PVC Pipe including cost of pipe and specials and labour including lowering in to trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour and lift charges, handling charges with an initial lead of 5 Km including encasing the pipe all round to a depth not less than 15 cm with gravel or selected earth available from the excavation etc., complete.and as directed by the Engineer-in-charge. 6 Refilling the basement and pipeline trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cms thick including disposing of the surplas earth with a lead of 200 mtrs.and as directed by the Engineer-in-charge. 7 CENTRIFUGAL PUMPS AND ACCESSORIES 10 HP Centrifugal Pump 80x65 ,840LPM and as directed by the Engineer-in-charge. 8 Supply and delivery at site the following accessories suitable for monoblock centrifugal pumps of different capacities,rates including. III) Starter Upto 10 HP and as directed by the Engineer-in-charge. 9 VI Earthing system confirming to IS 3049/1968 and as directed by the Engineer-in-charge. 10 VII LT Cable 4x25 Sq.mm and as directed by the Engineer-in-charge.

11 Indoor type board Consists of 2 Units Meter Board unit and Panel board unit a) Meter board unit : One number MS box of size 350 x 380 x 150 mm fabricated out of 2 mm thick sheet metal scalable door and arrangements for mounting CTs (if any) to connect 3 PH/4 wire energy metre cable box etc., complete A transparent glass pieces should be provided for the protection where the energy meter reading could be read out. b) Panel Board unit : One number cubical type of control panel board of size 350 x 380 x 150 mm fabricated out of 2 mm thick sheet metal to operate on 3 PH/4 wire 50 Hz/400/440 volts AC supply. i) One number brand new best make flush type motor control switch as per IS:6875 with latest ammendments b) 6 to 35 Hp - 30 Amphs ii) One number of brand new best make voltameter of range 0.600/volts as per IS 1248 witrh latest ammendments iii) One number of brand new best make single phase preventer as per IS 3231 with latest ammendments. iv) One number of brand new best make ammeter as per IS 1248 with latest ammendments. v) Indicator lamps for visual indication of electrical power as per IS:9224-1979 with latest ammendements vi) One number of 30Amps DP switch of brand new best make as per IS:9224-1979 with latest ammendments vii) Earthing : The box shall be provided with plate bolt and nuts viii) Rewieable fuse units :

b) 6 to 35 Hp - 30 Amphs ix) Danger board: Danger board confirming to KEB standards should be provided on the panel These 2 units (A & B) complete shall be mounted on extra sheet metal of 20mm thick and screwed on to the box with specified above proper space in between. This complete unit shall be mounted on the MS angle of size 65x65x8mm fabricated pedestal and epoxy painted with rust resistant primer and two coats of ash grey/olive green paints. these two units specified above with proper space in between the shall be provided and rubber bushed retained in position so that they could be used as and when required complete panel writing should be done with cable as per IS: 694/1990 with its latest amendments.Complete unit comprising of all the above items with one number best make brand new push button operated starter as per IS: 5124 and its latest ammendments with protective relay. b) 6-10 Hp and as directed by the Engineer-in-charge. 12 Supply and delivery at site 100 mm dia 14.70 Kg/m heavy duty GI pipes as per IS 1239 (Part-I) 1973 and 1239 (Part-II) 1968 threaded ends. and as directed by the Engineer-in-charge. 13 Supply and delivery at site wrought mild steel fitting (galvanized) 100 mm dia bends confirming to IS 1239-11/ 91 with latest amendments if any. and as directed by the Engineer-in-charge. 14 Laying and jointing GI pipes without earthwork including aligning to line slope, fixing collars, elbows, bends, gland cocks and other fittings with cuts and threads wherever neccessarry conveying the materials from stores to the workspot and returning surplus materials from the workspot to the stores with all leads. 100 mm Dia GI pipes and as directed by the Engineer-in-charge.

Part-II(Electrical works) part-A Running 11 kv line

1.00 Running single circuit 11 kv 3ph power Line on supports with an average span of 50 mtr using Rabbit ACSR Cconductor as per CDS no3 of 2010-2011 SR 2.00 Providing 2 pole structures at the tapping point using 8 mtr rcc poles as per CSD.15 PART-B ERRECTION OF TRANSFORMER 3.00 Errection of 3 ph 11000/433 v, 25 KVA, Distn Trans Center as per CDS no3 of 2010-2011 SR PART-C Extension of LT 3 ph,4 w 1 RCC Pole 8 mtr long 2 Pin cross arms with clamps bolts and nuts complete set 3 8 Kv Strain Insulators 4 Guy sets complete set 5 Spiral Earth Electrodes 6 Weasel ACSR Conductor with 1.5 % Sag 8 Service Connection charges

uom_name Cum

quantity 772.06

rate 163.00

Cum

0.86

3748.00

Cum

3.75

4225.00

Nos

1.00

12911.00

Rmt

1600.00

236.00

Cum

576.00

70.00

Nos

1.00

39178.30

Nos

1.00

14425.00

Nos Rmt

1.00 20.00

1731.00 248.11

Nos

1.00

11110.00

Rmt

12.00

1125.36

Nos

2.00

372.74

Rmt

12

43

Km Set Nos.

1.5 1 1

167033.00 250549.5 30299.00 86933.00 86933 0 3625 452 64 815 232 3256.6 1400 377626.1 30299 0

Set Km Set Set Set Km Nos.

1 2 8 1 1 0.2 1

3625.00 226.00 8.00 815.00 232.00 16283.00 1400.00

Vous aimerez peut-être aussi