Objectives
Upon completion of this module students should know the following:
Basic Software maintenance Basic hardware maintenance
ver. 07-06-10
Software Upgrade
Each AU or SU holds within two versions (Main and Shadow) When an upgrade needs to be performed
First, the file version is transferred to the NPU Second, the unit (AU or SU) is set to download the version from the NPU Third, the unit (AU, SU or NPU) is set to reboot and load the shadow version Fourth, the unit (AU,SU or NPU) is set to mark the running version (shadow) as main version
ver. 07-06-10
Software Upgrade
Step I : file version is transferred to the NPU
Shadow
New AU SU SW version
ver. 07-06-10
Software Upgrade
Step II : the unit (AU or SU) is set to download the version from the NPU
AU / SU NPU
Flash Mem (TFTP)
New AU/SU SW version
Main
Current running SW version
Main
Current running SW version
Shadow
ver. 07-06-10
Software Upgrade
Step III: the unit (AU, SU or NPU) is set to reboot and load the shadow version
AU / SU NPU
Flash Mem (TFTP) Main
Previous running SW version
Main
Previous running SW version
ver. 07-06-10
Software Upgrade
Step IV : the unit (AU,SU or NPU) is set to mark the running version (shadow) as main version
NPU
Flash Mem (TFTP)
Shadow
Previous running SW version
AU / SU
Shadow
Previous running SW version
Main
Current running SW version
Main
Current running SW version
ver. 07-06-10
Software Upgrade
Downloading The File to The NPU
Verify that IP connectivity is working properly by pinging the NPU (DATA or MGMT port)
In the command prompt enter the following command: ping <NPU IP Address> e.g ping 10.10.10.1
ver. 07-06-10
Software Upgrade
Loading The New File
To upgrade an NPU skip to the next step, set the unit (AU or SU) to download a file from the NPU and enter the file name to download Set the unit (NPU, AU or SU) to run from the shadow version The unit reboots and loads the shadow version In order to load the new software permanently, the unit (NPU, AU or SU) needs to set the shadow version as main At the next boot the unit marks the shadow version as main
ver. 07-06-10
10
ver. 07-06-10
11
ver. 07-06-10
12
Storing the backup file in a local computer Requires TFTP Server (e.g Solarwinds)
In the command prompt enter the following command: tftp -i <NPU IP Address> GET <File Name> <Path> e.g tftp -i 10.10.10.1 GET backup.res c:\NPU_Backup\ The transfer operation has completed when the following message appears: "Transfer successful: XXXXXX bytes in YY seconds, ZZZZZZ bytes/s" e.g Transfer successful: 2598936 bytes in 13 seconds, 199918 bytes/s
Alvarion Training Services
ver. 07-06-10
13
ver. 07-06-10
14
The Backup option enables creating a backup file of the entire SU configuration The SU downloads/uploads the configuration file to/from a configured TFTP server Prior performing the backup a message appears asking whether to execute the backup process The file is encrypted and cannot be edited However, it can be downloaded to other SUs using a DOS based TFTP application
All Rights Reserved Alvarion 2007
ver. 07-06-10
15
Connect to the SU
In the command prompt enter the following command: Telnet <SU ODU IP Address> e.g telnet 192.168.254.251
ver. 07-06-10
16
Connect to the SU
In the command prompt enter the following command: Telnet <SU ODU IP Address> e.g telnet 192.168.254.251
ver. 07-06-10
17
Corrective Maintenance
General
The corrective maintenance is performed upon replacing one of the following units:
Any card (PIU, PSU, AU or NPU) from the modular base station Described in the Installation presentation AVU AU ODU Described in the Installation presentation Micro Base Station Described in the Installation presentation Described in the Installation presentation SU ODU Described in the Installation presentation
All Rights Reserved Alvarion 2007