Académique Documents
Professionnel Documents
Culture Documents
2006/95/EC Low Voltage Directive Test Standard IEC/EN60598-1:2004 2004/108/EC EMC Directive-Exempt
This Test Report documents Regulatory Compliance Evaluations and Validation testing of the noted GYT San Diego, Inc, Model: Solar Guard Display St0443 to validate CE Mark Compliance. This Evaluation and testing was conducted by rd STORK Garwood Laboratories Inc, an independent, competent 3 party Regulatory Compliance Testing Organization with credentials appropriate for this task. It is the express opinion of Stork Garwood Laboratories Inc., that the noted GYT San Diego, Inc, Model: Solar Guard Display St0443and their Appended Instructions are compliant and eligible to bear the CE Mark under a Declaration of Conformity.
Page 1 of 21
TECHNICAL FILE
Report: GLIO 8590
Testing and Validation: Conducted by Stork Garwood Laboratories Inc. Safety Standards, IEC/EN60598-1 2004 Safety of Luminaries
Page 2 of 21
TABLE OF CONTENTS
ITEM DESCRIPTION
EU Technical Construction File (TF) Report - Title Page EU Technical File System Overview Table of Contents Responsible Signatures & Document History Testing Information & Client Information EU Declaration of Conformity (DoC) - Document Summary of Product Qualifications to International Requirements and the European Union (EU) Statement of Organizational Charter - Competent 3rd Party Declaration of Conformity Rationale Purpose of the Declaration of Conformity (DoC) Purpose of the Technical File (TF) Introduction to Qualifications CE Marking Instructions Validation of CE Mark Compliance Calibration Details CE Mark Template Operation of Equipment Under Test (EUT) Product Specification Product Photos Product Testing Wiring Diagram Instructions
PAGE
1 2 3 4 5 6 7 8 8 9 9 10 10 10 10 11 12 12 13-17 18 19 20-21
Section 1.0 1.1 1.2 1.3 1.4 Section 2.0 2.1 2.2 2.3 Section 3.0 Section 4.0 4.1 Section 5.0 Section 6.0 Section 7.0 Section 8.0
Page 3 of 21
RESPONSIBLE SIGNATURES
This report is intended for the use by the organization to which it is addressed, and will not be made available to any other parties without the expressed written consent of the aforementioned organization. This report shall not be reproduced, except in full, without the written approval of Stork Garwood Laboratories, Inc.
WRITTEN BY:
TESTED BY:
VALIDATED BY:
DOCUMENT HISTORY
Revision 1 Issue Date September 2009 Description Of Modifications Initial Release Revised By ------------------Reviewed By Chuck Helton
Page 4 of 21
CLIENT INFORMATION
Quote Number
GLIO 8590 GYT San Diego, Inc
City, State Zip San Diego, CA 92154 Contact Name Wilberth Santoyo
General Manager
STORK GARWOOD LABORATORIES, INC. 143 Calle Iglesia San Clemente, CA 92672 USA (949) 361-9189 (949) 361-9597 www.garwoodlabs.com Contact Name Chuck Helton Title Director - Product Safety E-Mail Address chuck.helton@us.stork.com Contact Name Don Bennett Title Laboratory Manager E-Mail Address don.bennett@us.stork.com
TESTING INFORMATION
Test and Technical Personnel Test Dates Maria Lumpkin, Technical Writer Nick McMillan, Test Technician Chuck Helton, Product Safety Director August 2009
Page 5 of 21
EMC STANDARDS EN 55015 RF Emissions and Immunity tests for Luminaries Exempt-All components Passive- Switch and Incandescent Bulb SAFETY STANDARD EN 60598-1 2004 Safety of Luminaries
Importers Name: Importers Address: EU City or Region: EU Country & Postal Code: Manufacturers Name: Manufacturers Address: City, State, Zip Description of Equipment: Model Numbers Date of Manufacture:
XXXXXXXXXXXXXXXXXXXXX Street Number Suite Number xxxBerParLonMadLisxxx xxxBel Fr Sp UK 123xxx GYT San Diego, Inc 2498 Roll Dr. San Diego, CA 92155 Glass Film Display Case Solar Guard Display St0443 MM -YY
We the undersigned hereby declare that the equipment specified above conforms to the noted Directives and Test Standards. Refer to the CE Mark Test Report, GLIO8590 including a Declaration of Conformity, Certification Documents and Test Results. The noted CE Mark Test report is available on request. IMPORTER Signature ____________________________ Typed Name___________________________ Title _________________________________ Date _________________________________ MANUFACTURER Signature _______________________________ Typed Name _____________________________ Title ___________________________________ Date ___________________________________
This Declaration is Valid when information as to the identity of the Importer is filled in. The noted Equipment is verified to be compliant by Chuck Helton, Product Safety Director, STORK Garwood Laboratories Inc., San Clemente, CA 92672, USA
Page 6 of 21
Section 1.0: Summary of Product Qualifications to International Requirements and the European Union (EU)
The equipment description and performance capabilities given in this section is based on information provided by GYT San Diego Inc. "Note that some aspects of the performance claims were not verified by STORK Garwood Laboratories, Inc., as those claims were not deemed Safety or Environmentally significant." This report documents the results of a series of Regulatory Compliance Evaluations, EMC tests and Product Safety Tests performed on the Solar Guard Display ST0443. The purpose of this series of evaluations and tests was to demonstrate compliance of the equipment with the essential requirements of the EU Low Voltage Directive (LVD) 2006/95/EC.and the EMC Directive 2004/108/EC.
General Information EU Directives Product Safety Standard 2006/95/EC Low Voltage Directive 2004/108/EC EMC Directive (Exempt) IEC/EN60598-1 2004 Safety of Luminaries
Page 7 of 21
Page 8 of 21
Page 9 of 21
Page 10 of 21
Page 11 of 21
Page 12 of 21
Aluminum Frame
To
Top View
Page 13 of 21
Bottom View
Clamp Bracket Riser tube serves as conduct for AC Cord Internal View Showing Luminaire
Page 14 of 21
Backside of IEC 60320 Type 8 AC Socket Internal Bottom View with Cover removed
Page 15 of 21
Page 16 of 21
Page 17 of 21
Input Testing
Leakage Current
Page 18 of 21
Page 19 of 21
Page 20 of 21
Page 21 of 21