Vous êtes sur la page 1sur 19

Switch-Disconnector-Fuse Switch-Disconnector Type FN

SALIENT FEATURES
High making & breaking capacity Due to Quad break construction. High Electrical & Mechanical life. Compact construction : To ensure light weight low operating torque switch which saves panel space. Easy to maintain contacts. Phase barriers : Interphase barriers are provided to eliminate the possibility of interphase short circuit. Features of FN series : Compact design saves space Electrodynamic Compensation Quad break Contact System Full AC - 23 A rating for the Complete range Highest fused Short Circuit Capacity Quick make / Quickbreak / Positive break Clear ON / OFF indicator Separate arcing / Current carrying zone High clearance & Creepages Separate bridge for each pole Maximum ground Clearance Phase barrier & Terminal Shroud as a Standard accessory Fuse stationary & Isolated from both sides Direct access to mounting & terminal screws Generous terminal capacity Replaceable contacts for enhanced life Suitable for vertical & horizontal orientation Wide range of Spares & Accessories Handle coupling as per IS 8623 Large Ground Clearance to eliminate possibility of phase-ground flash over.

The handle coupling has the following user-friendly features. Large terminals to accommodate Aluminium bus bars. Terminal shrouds, to protect against phase-phase short circuit The terminals can be shrouded for protection against phase-phase short circuit through an external conducting path and also for protection against accidental human contact to live terminals.

Easy fixing of handle on panel door by two screws. Door interlock for safety of operating personnel when switch is ON. The interlock can be defeated if required. Built-in padlocking arrangement to lock the unit in either ON or OFF position. The handle coupling can take a mismatch or 3mm in all directions.

Clear ON / OFF indication is provided on the switch (by a red pointer)

Contact System : Contact system is QUAD BREAK. There are no. of parallel moving contacts per pole per break. Hence, better Arc Quenching & more electrical life of contacts. Each pole has separate bridge, carrying the moving contacts, achieving a high order of interphase separation & avoiding phase-phase flash over.

Built-in neutral : Switch-Disconnector-Fuse consist of an integral neutral, making the units suitable for 3 phase, 4 - wire application. FN 32 / 63 has switched neutral while higher ratings have isolable neutral.

Fuses remain stationery during switching operation. Fuses are isolated from both sides. This offers safety to operating personnel while replacing fuses. The Switch-Disconnector-Fuse units can be mounted at any angle in a vertical plane. SDF Interior in Sheet Steel Enclosure : Complete range of S-D-F is also available in attractive powder coated sheet steel enclosures. FN 32 / 63 in sheet steel enclosure comes fitted with gland plate.

Mechanism : This mechanism is front operated quick-make / quick-break and independent of speed of operation.

TECHNICAL DATA
SWITCH-DISCONNECTOR-FUSE UNITS, TYPE FN CONFORMS TO IS 13947 (PART-3) / IEC 60947-3
TYPE DESIGNATION No. of Poles Neutral # Service temperature Rated operational voltage (Ue) Rated insulation voltage (Ui) Rated impulse withstand voltage (Uimp) Rated Frequency Conventional enclosed thermal current at 400C (Ithe) Rated operational current (le) AC - 23 A utilization category
0

FN 32 3+Neutral Switched C V V kV Hz A A -20 to 50 415 690 8 50 - 60 32 32 320* 256* 80 32/HF/14x51 14 15000 mm mm


2

FN 63 3+Neutral Switched -20 to 50 415 690 8 50 - 60 63 63 630* 504* 80 63/HF/14x51 29 15000 35 35 M 6 x 12

FN 100 3+Neutral Isolable -20 to 50 415 690 8 50 - 60 100 100 1000 800 100 100/HN/00 45 15000 95 50 M 8 x 20

FN 125 3+Neutral Isolable -20 to 50 415 690 8 50 - 60 125 125 1250 1000 100 125/HN/00 57 15000 95 50 M 8 x 20

FN 160 3+Neutral Isolable -20 to 50 415 690 8 50 - 60 160 160 1600 1280 100 160/HN/00 57 15000 185 50 M 8 x 20

FN 200 3+Neutral Isolable -20 to 50 415 690 8 50 - 60 200 200 2000 1600 100 200/HN/0 92 10000 240 120 M 10 x 30

FN 250 3+Neutral Isolable -20 to 50 415 690 8 50 - 60 250 250 2500 2000 100 250/HN/1 115 10000 240 120 M 10 x 30

FN 315 3+Neutral Isolable -20 to 50 415 690 8 50 - 60 315 315 3150 2520 100 315/HN/1 145 10000 400 240 M 10 x 30

FN 400 3+Neutral Isolable -20 to 50 415 690 8 50 - 60 400 400 4000 3200 100 400/HN/2 175 10000 2 x 400 240 M 12 x 40

FN 630 3+Neutral Isolable -20 to 50 415 690 8 50 - 60 630 630 6300 5040 100 630/HN/3 270 10000 2 x 625 400 M 16 x 50

FN 800 3+Neutral Isolable -20 to 50 415 690 8 50 - 60 800 800 8000 6400 100 800/HN/3 270 3000 2 x 625 400 M 16 x 50

Rated making capacity (436 V, cosO=0.35) A Rated breaking capacity (436 V, cosO=0.35) A Rated fused short circuit current kA with L&T fuses, rating A / Type / Size Capacitor duty - Connected415 V, 50 - 60 Hz Mechanical life (Operating cycles) Terminal capacity (main) Terminal capacity (neutral) Terminal screw DC RATING AT 220 V DC No. of poles in series, utilization category at rated current kVAr

35 35 M 6 x 12

mm

3, DC-23 A

3, DC-23 A

2, DC-23 A

2, DC-23 A

2, DC-23 A

2, DC-23 A

2, DC-23 A

2, DC-22 A

2, DC-22 A

2, DC-22 A

2, DC-22 B

* -------- Power factor = 0.45 as required in IS 13947 - (part 3). # ------- For FN 125 to FN 800 Switched - Neutral is available as accessory.

TECHNICAL DATA
SWITCH DISCONNECTOR - TYPE FN Conformance to IS 13947 (Part 3) and IEC: 60947-3
Type Designation No. of poles Neutral Service temperature Rated operational voltage (Ue) Rated insulation voltage (Ui) Rated impulse withstand voltage (Uimp) Rated frequency Conventional Enclosed thermal current at 400C Rated operational current le AC 20 A utilization category AC 21 A utilization category AC 22 A utilization category AC 23 A utilization category DC rating at 220 V DC No. of poles in series, utilization category at rated current Rated making capacity (436 V, cosO-0.35) Rated breaking capacity (436 V, cosO-0.35) Capacitor duty - 415 V 50 - 60 Hz Mechanical life (operating cycles) Terminal capacity (main) Terminal capacity (neutral) Terminal screw Short circuit withstand current (duration 1 secs) Rated fused short circuit current with L&T fuses rating, A / Type Size kA mm2 mm2 mm kA 1.5 80 32 / HF 1.5 80 63 / HF 4 100 100 / HN 00 4 100 125 / HN 00 6 100 200 / HN 0 10 100 250 / HN 1 14 100 315 / HN 1 14 100 400 / HN 2 20 100 630 / HN 3 20 50 800 / HN 3 A A kVAR 3, DC 23 A 320 256 14 15000 35 35 M 6 x 12 3, DC 23 A 630 504 29 15000 35 35 M 6 x 12 2, DC 23 A 1000 800 45 15000 95 50 M 8 x 20 2, DC 23 A 1250 1000 57 15000 95 50 M 8 x 30 2, DC 23 A 2000 1600 92 10000 240 120 M 10 x 30 2, DC 23 A 2500 2000 115 10000 400 120 M 10 x 30 2, DC 22 A 3150 2520 145 10000 400 120 M 10 x 30 2, DC 22 A 4000 3200 175 10000 2 x 400 240 M 12 x 40 2, DC 22 A 6300 5040 270 10000 2 x 625 400 M 16 x 50 2, DC 22 A 8000 6400 270 3000 2 x 625 400 M 16 x 50 2, DC 22 B 10000 8000 270 32 32 32 32 63 63 63 63 100 100 100 100 125 125 125 125 200 200 200 200 250 250 250 250 315 315 315 315 400 400 400 400 630 630 630 630 800 800 800 800 1000 1000 1000 1000
0

FN 32 3+Neutral Switched C V V kV Hz A -20 to 50 415 690 8 50 - 60 32

FN 63 3+Neutral Switched -20 to 50 415 690 8 50 - 60 63

FN 100 3+Neutral Isolable -20 to 50 415 690 8 50 - 60 100

FN 125 3+Neutral Isolable -20 to 50 415 690 8 50 - 60 125

FN 200 3+Neutral Isolable -20 to 50 415 690 8 50 - 60 200

FN 250 3+Neutral Isolable -20 to 50 415 690 8 50 - 60 250

FN 315 3+Neutral Isolable -20 to 50 415 690 8 50 - 60 315

FN 400 3+Neutral Isolable -20 to 50 415 690 8 50 - 60 400

FN 630 3+Neutral Isolable -20 to 50 415 690 8 50 - 60 630

FN 800 3+Neutral Isolable -20 to 50 415 690 8 50 - 60 800

FN 1000 3+Neutral Isolable -20 to 50 415 690 8 50 - 60 1000

SPARES & ACCESSORIES


Wide range of spares & accessories are available for Switch-Disconnector-Fuse units type FN. ACCESSORIES : SWITCHED NEUTRAL : In FN 32 / 63 Switched-Neutral pole is an integral part of the Switch-Disconnector-Fuse. For higher ratings, a double break, site-fitted switched neutral pole can be provided. This is operated by the main mechanism. TERMINAL SHROUD : The terminals can be shrouded for protection against phase-short circuit through an external conducting path and against accidental human contact with live terminals. MECHANICAL INTERLOCK KIT : Two Switch-Disconnector-Fuse units can be interlocked by mechanical interlock kit. After interlocking, the following three positions are possible. 1) SDFU 1 in ON position SDFU 2 in OFF position. 2) SDFU 2 in ON position SDFU 1 in OFF position 3) Both SDFUs in OFF position Hence two mechanically interlocked SDFUs can be used as a change over switch. CASTELL INTERLOCK : Switch-Disconnector-Fuse units can be locked on OFF position with help of castell interlock. Castell interlock can also be used to interlock two S-D-F units. (Different variety of locks are available) FUSE PULLER : A fuse puller is provided which facilitate easy & safe removal of fuses. HANDLE COUPLING (Type A & B) : lrrespective of the switch orientation (vertical or horizontal), operation in any of the four quadrants is possible by selecting right handle coupling (Refer table on next page) AUXILIARY CONTACTS : 1 NO + 1 NC auxiliary contact is available as an accessory. This can be suitably wired in the control circuit. Rated operational current le (AC - 15) - 4 A Rated operational voltage Ue - 415 SPARES : Moving Contact : Moving contacts are available for ranges FN 100 to FN 800. One set of moving contact spare contains, spring, guide & moving contact. Front Housing essambly : Complete front housing assembly is available from FN 100 to FN 800. SHAFT EXTENSION KIT : Shaft length can be increased with shaft extension kit.

Spares & Accessories for FN Range - Ordering Information


Versions Spares Moving Contact Front Housing Assembly Terminal Shroud Kit Switched Neutral Kit Aux. Contact (1 NO + 1 NC) Accessories Handle Coupling (Type - A) Handle Coupling (Type - B) Handle Coupling (Type - CE) Fuse Puller Shaft Extension Kit Mechanical interlock Kit Castell Lock (Type A-Type M) Ordering Suffix - 0000 for all. FN 32 FN 63 Not Available Not Available SK91190 Built-in SK91302 SK91257 SK91277 SK91337 SK91185 Not Available Not Available Not Available SK95600 SK95232 SK00333-SK00344 FN 100 FN 125/160 FN 200 SK91374 ST31679 FN 250 SK91375 ST31729 FN 315 SK91376 ST31681 SK91346 SK95517 SK91330 SK91259 SK91279 Not Available SF90126 SK91331 SK95545 SK00345-SK00356 FN 400 SK91377 ST31682 FN 630 SK91378 FN 800 SK91379 SK91373 ST31677 ST31678 SK91137 SK95233 SK91328 SK91258 SK91278

ST31683 ST31730 SK91347 SK95546

SK91335 SK95516 SK91329

SELECTION OF HANDLE
SEEN FROM FRONT OF THE DOOR
SR. NO. HANDLE (OFF) POSITION
1

OPERATING QUADRANT (HAND)

SWITCH ORIENTATION

DOOR CUT-OUT

HANDLE COUPLING TYPE

1
OR
1

B
OR
0

3
OR
0

4
OR

5
1

A
OR

6
1

B
OR

B
0

OR

A
0

OR

Note : Arrow ( ) indicates position of Interlock Defeat Key Type A : supplied as standard with all S-D-Fs Type B : supplied on request

OVERALL DIMENSIONS
SWITCH-DISCONNECTOR-FUSE TYPE DIN FN 32 / 63
OVERALL DIMENSIONS - FN 32 / 63
A1 6 SQ.

ASSEMBLY OFHANDLE COUPLING ON DOOR - FN 32 / 63

100 MIN
5

47

150

SQ. 65 40
35 83.5

AUXILIARY CONTACT BLOCK (OPTIONAL ACCESSORY)

HINGE
128 113.2 29.6 5 55

CHEESE HEAD SCREWS SWITCH IN OFF POSITION

95

75

16 31 15.1 29 27 27

TERMINAL SHROUD (OPTIONAL ACCESSORY)

2 MOUNTING HOLES FOR M4 SCREWS

DRILLING DETAILS FN 32 / 63
55

79

DRILLING DETAILS ON DOOR FOR MOUNTING HANDLE COUPLING SEEN FROM FRONT OF THE DOOR
40 0.25

DRILLING DETAILS ON BASE PLATE FOR MOUNTING SWITCH SEEN FROM FRONT OF THE DOOR 2 HOLES 4 0.1 FOR M3.5 SCREWS HOLES 32 0.25

2 HOLES SUITABLE FOR M4 SCREWS


75

40 0.25

OPERATING SHAFT CENTER MISMATCH 3 PERMISSIBLE

Note: All dimensions are in mm.

CLEAR INSIDE OF THE CUBICLE

DOOR THICKNESS MAX. 2 mm.

150 3

SWITCH-DISCONNECTOR-FUSE TYPE DIN FN 100 / 125 / 160


10 PHASE BARRIER

170

77.5

TERMINAL SHROUD (OPTIONAL ACCESSORY) 216 (WITH AUX. CONTACT BLOCK) 7 22 5 7 204 160

AUX. CONTACT BLOCK (OPTIONAL ACCESSORY)

69 94

26

125

TYPE FN 100 / 125 FN 160

A 154 164

B 20 25

M5 SCREW EARTHING M 6 SCREW

FN 125

75

20 39.6

B 48 47

9 47

SWITCH-DISCONNECTOR-FUSE TYPE DIN FN 200 / 250


PHASE BARRIER

2.5

96

83.5 111.5

12.5

247 (WITH AUX. CONTACT BLOCK) 238 188 24.7 M10 BOLT

AUX. CONTACT BLOCK (OPTIONAL ACCESSORY) TERMINALSHROUD (OPTIONAL ACCESSORY)

43.2

B C D

170 180 190

109

210

108.5

M8 BOLT M5 SCREW EARTHING 29 39 30 55 12.5 HOLE 56 56

TYPE FN 200 FN 250

A B D C 190 162.5 178 187.5 206 108.5 194.5 204

136 A

Note: All dimensions are in mm.

122

142 159

164

OVERALL DIMENSIONS
ASSEMBLY OF HANDLE COUPLING ON DOOR FN 100 / 125 / 160 / 200 / 250

160 150 MIN. PADLOCK, CLAMP 5 TO 8.5 mm.

HINGE

PUSH HERE TO DEFEAT INTERLOCK

DOOR THICKNESS MAX. 2 mm

SWITCH IN OFF POSITION

DIMENSION FN 100 / 125 / 160 FN 200 FN 250 200 216 180 A

DRILLING DETAILS FN 100 / 125 / 160 / 200 / 250


DRILLING DETAILS ON DOOR FOR MOUNTING HANDLE COUPLING SEEN FROM FRONT OF THE DOOR DRILLING DETAILS ON BASE PLATE FOR MOUNTING SWITCH SEEN FROM FRONT OF THE DOOR

CLEAR INSIDE OF THE CUBICLE

CHEESE HEAD SCREW

54.5

SQ. 90

A3

74.4

60 0.25

2 HOLES 4 0.1 FOR M3.5 SCREWS

HOLES 50 0.25 OPERATING SHAFT CENTER MISMATCH 3 PERMISSIBLE 60 0.25 4 HOLES SUITABLE FOR M6 SCREWS D

TYPE A B D C FN 100 / 125 / 160 26 22 160 125 FN 200 43.2 24.7 188 170 FN 250 43.2 24.7 188 170

Note: All dimensions are in mm.

10

SWITCH-DISCONNECTOR-FUSE TYPE DIN FN 315 / 400


PHASE BARRIER

250

240

17.5

146

AUX. CONTACT BLOCK

291 (WITH AUX. CONTACT BLOCK) 280 215 17 24.5 16.3 5 TERMINAL SHROUD

BOLT'C'

5 9

45.7

137

206

TYPE FN 315 FN 400

A 103 102

B 220 228

C M10 M12

146

195

M5 SCREW EARTHING M10 BOLT

43 60.5 70

40 70

SWITCH-DISCONNECTOR-FUSE TYPE DIN FN 630 / 800


PHASE BARRIER FUSE

174 175

270 260

24.5

200

225.5 250.5 147 8 17 24.5 13.3 5 347 (WITH AUX. CONTACT BLOCK) 336 271 TERMINAL SHROUD 5 45.7 105 137 175 182 48 60 71 90 M16 BOLT 195 218 9

113 AUX. CONTACT BLOCK 117.5 261

M5 SCREWEARTHING M12 BOLT

182

238

Note: All dimensions are in mm.

11

OVERALL DIMENSIONS
ASSEMBLY OF HANDLE COUPLING ON DOOR FN 315 / 400 / 630 / 800
230 150 MIN.

PADLOCK CLAMP f 5 TO f 8.5 mm

O
54.5 HINGE CHEESE HEAD SCREW DOOR THICKNESS MAX. 2 mm. SQ. 90 74.4 CLEAR INSIDE OF THE CUBICLE 250 3 FOR MOUNTING SWITCH SEEN FROM FRONT OF THE DOOR

PUSH HERE TO DEFEAT INTERLOCK

SWITCH IN OFF POSITION

TYPE A FN 315 / FN 400 250 FN 630 / FN 800 270

DRILLING DETAILS FN 315 / 400 / 630 / 800


DRILLING DETAILS ON DOOR FOR MOUNTING HANDLE COUPLING SEEN FROM FRONT OF THE DOOR DRILLING DETAILS ON BASE PLATE

24.5 HOLE 500.25

600.25

OPERATING SHAFT CENTER MISMATCH 3 PERMISSIBLE

45.7

600.25

2 HOLES 40.1 FOR M3.5 SCREWS

TYPE A FN 315 / FN 400 215 FN 630 / FN 800 271


Note: All dimensions are in mm.

12

175

4 HOLES SUITABLE FOR M8 SCREWS

FN IN SHEET STEEL ENCLOSURE

H J

G I A

O K

4 Holes 6.5

Extreme Overall dimension TYPE FN 32 / 63 FN 100 / 125 / 160 FN 200 FN 250 / 315 / 400 FN 630 / 800 A 245 288 335 365 421 B 238 265 265 265 285 C 196 245 265 315 337

Basic Enclosure dimension D 230 273 320 350 406 E 226 253 253 253 273 F 153 183 203 253 273

Cutout for Cables G 190 233 280 310 366 H 73 104 124 185 185

Gl and Plate mounting dimension I J 210 80 253 110 300 130 330 191 386 191

Enclosure mounting dimension K L 170 165 213 193 260 193 300 203 346 223

Note: All dimensions are in mm.

13

OVERALL DIMENSIONS
SWITCH-DISCONNECTOR-FUSE TYPE BOLTED
6 SQ. 5

FN 32 / 63

FN 100 / 125
O 37 Max Fuse Size A4 According to IS 13703

180

170

83.5

77.5

35

29.6 5

113.2 55 1.2
2 MOUNTING HOLES FOR M4 SCREWS

22 5

204 160 20 9

69 Aux. Contact Block 12


TERMINAL SHROUD

157.5 129

150

TERMINAL SHROUD (OPTIONAL ACCESSORY)

44.5

95 75

79

26

125

16 31 15.1 29 27 27

M5 SCREW EARTHING M6 SCREW

20 M6 39.6

48

47

47

FN 200 / 250
PHASE BARRIER 111 FUSE SIZE B2 ACCORDING TO IS13703 E

%%C42 MAX. 2.5 179 (MAX.) A B

M10 BOLT

96

111.5

AUX. CONTACT BLOCK

247 (WITH AUX. CONTACT BLOCK) 24.7 12.5 M8 BOLT 5 7 238 188 TERMINAL SHROUD

180 210

43.2

109

170 190

108.5

M5 EARTHING SCREW

29 39 55

30 56 56

DIM A FN 200 200 FN 250 216

B 190 206

C 4 5

D E FUSE 83.5 187.5 200 A 84.5 204 250 A

Note: All dimensions are in mm.

14

94 136 154

75

122

SWITCH-DISCONNECTOR-FUSE TYPE BOLTED FN 315 / 400


111
O66 MAX. B (MAX.) REFER TABLE

PHASE BARRIER

FUSE SIZE ACCORDING TO IS 13703 (REFER TABLE)

250 240

238

BOLT-C (REFER TABLE) A (REFER TABLE)

146

137

AUX. CONTACT BLOCK

174 200

17 16.3

24.3

291(WITH AUX. CONTACT BLOCK) 275 215 TERMINAL SHROUD 5 5

45.7

9 43 60.5 70 40 70 175 195 113

M5 SCREW EARTHING M10 BOLT

SWITCH-DISCONNECTOR-FUSE TYPE BOLTED FN 630


PHASE BARRIER FUSE SIZE C2 ACCORDING TO IS 13703 25.4 212 133 25.4

146

O77 MAX. M16 BOLT

137

249 (MAX.) 261

270 260

147 103 6

17 13.3 5

24.5

347 (WITH AUX. CONTACT BLOCK) 330 271 TERMINAL SHROUD 5 9

AUX. CONTACT BLOCK

182 218

45.7

M5 SCREW EARTHING M12 BOLT

182

49

71

90

60

90

175 195

117.5

Note: All dimensions are in mm.

15

CYLINDRICAL HRC FUSES


FUSE LINKS TYPE HF
(Fuse links with cylindrical contact caps) Conform to IEC 60269 / IS 13703 Low watt loss - Saving in power Low let through energy High breaking capacity - 80 kA Rated voltage - 415 V Immediate fault indication through Red Pop up indicator. Lower Power loss in our fuses result in cooler running of asociated products.

ORDERING DETAILS
Fuse Rating (A) 2 4 6 8 10 16 20 25 32 40 50 63 Cat. Nos. SF90144 SF90145 SF90146 SF90147 SF90148 SF90150 SF90151 SF90152 SF90142 SF90143 SF90158 SF90159 14 *51 MM Size Suitable for S-D-F type FN 32, 63 32, 63 32, 63 32, 63 32, 63 32, 63 32, 63 32, 63 32, 63 63 63 63

16

FUSE LINKS TYPE HN


(Fuse links with blade contacts) Conforms to IEC 60269 / IS 13703 Low watt loss - Saving in power Cooler running of associated products Low let through energy High breaking capacity - 100 kA Immediate fault indication Rated voltage - 415 V

Size of the fuse link Size 000

Rating (A) 63 80 100

Cat. Nos. SF94940 SF94941 SF94942 SF94027 SF94028 SF94029 SF9430 SF94939 SF94128 SF94129 SF94130 SF94131 SF94132 SF94230 SF94231 SF94232 SF94233 SF94234 SF94332 SF94333 SF94334 SF94335 SF94434 SF94435 SF94436 SF94437 SF94938

Rated watt loss 5.3 6.2 7 5.7 6.9 7.5 9.8 8.3 9.1 11.3 12.7 14.5 10.3 12.3 14.3 17.3 25.5 14.1 16.9 20.2 24.9 20.5 26.7 36.1 42.2 48

Watt loss limits as per IS 13703 100 Amp, Fuse-7.5 W

Suitable for S-D-Funits type FN or equivalent 100, 125, 160 100, 125, 160 100, 125, 160

Size 00

63 80 100 125 160

100 Amp, Fuse-7.5 W

100, 125, 160 100, 125, 160 100, 125, 160 125, 160 160

Size 0

80 100 125 160 200

160 Amp, Fuse-16 W

200 200 200 200 200

Size 1

125 160 200 250 315

250 Amp, Fuse-23 W

250, 315 250, 315 250, 315 250, 315 250, 315

Size 2

200 250 315 400

400 Amp, Fuse-34 W

400 400 400 400

Size 3

315 400 500 630 800

630 Amp, Fuse-48 W

630, 800 630, 800 630, 800 630, 800 800

Fuse-pulling handle should be used for safe and easy removal of fuse links (for HF : SK91185 & for HN : SF90126)

17

FUSE LINKS TYPE HG AND HQ


(Fuse-links for bolted connections) Conforms to IEC 60269 / IS 13703 Low watt loss Low let through energy High breaking capacity - 80 kA Rated voltage - 415 V

TYPE HQ
Size of the fuse A1 Rating (A) 2 4 6 10 16 20 25 32 20 25 32 50 63 4 6 10 16 20 25 32 35 50 63 80 100 125 80 100 125 125 160 200 250 315 315 355 400 400 500 630 630 Cat. Nos. Suitable for S-D-F units type FN or equivalent 32, 63 32, 63 32, 63 32, 63 32, 63 32, 63 32, 63 32, 63 100, 125, 160 100, 125, 160 100, 125, 160 100, 125, 160 100, 125, 160 100, 125, 160 200 200 200 250, 315 315 400 400 400 630 630 630 Power Loss 0.3 0.5 1.2 1.4 1.8 2.2 2.9 3.0 2.4 3.1 3.4 4.0 4.7 0.8 1.4 1.5 0.2 2.8 3.8 4.4 4.5 6.2 6.8 9.1 6.2 6.8 9.2 10.5 16.0 15.0 19.5 20.5 28 32 32 34 38 38 50 55 58

A1L

A2

A3

A4

B1

B2 B3

B4 C2

C3

ST30736 ST30737 ST30738 ST30739 ST30740 ST30741 ST30742 ST30743 ST34527 ST34528 ST34529 ST35827 ST35828 ST30747 ST30748 ST30749 ST30750 ST30752 ST30753 ST30753 ST30759 ST30760 ST30761 ST30767 ST30768 ST30769 ST30774 ST30775 ST30776 ST30777 ST30778 ST30779 ST30781 ST30782 ST30782 ST30783 ST30784 ST30785 ST30786 ST30787 ST30788

TYPE HG
Rating (A) 2 4 6 10 16 20 25 32 Size F1 F1 F1 F1 F1 F1 F1 F1 Cat. Nos. ST30725 ST30726 ST30727 ST30728 ST30729 ST30730 ST30731 ST30732 Power Loss 0.3 0.5 1.2 1.4 1.8 2.2 2.9 3.0

18

ORDERING INFORMATION
SWITCH-DISCONNECTOR-FUSE AND SWITCH-DISCONNECTOR TYPE FN
ORDERING INFORMATION: Orderig Suffix OOOO for all * Example: FN 32 Interior with handle * Ordering Information - SK95518OOOO

Type Designation Description S-D-F Suitable for DIN Fuses Interior with handle TPN Interior without handle TPN Interior in sheet steel enclosure Interior with handle TP S-D-F Suitable for BS Fuses Interior with handle TPN Switch-Disconnector Interior with handle TPN SK95541 SK955540 SK95571 SK95405 SK95607 SK95653 SK95651 SK95570 SK95009 SK95714 SK95588 SK95518 SK95544 SK95612 SK95421 SK95420 SK95613 SK95569 ST30287 SK95568 SK95001 SK95000 SK95005 ST27894 SK95713 SK95712 SK95715 SK95418 SK95417 SK95511 SK27895 FN 32 (4 Pole) FN 63 (4 Pole) FN 100 FN 125 FN 160 FN 200

Type Designation Description S-D-F Suitable for DIN Fuses Interior with handle TPN Interior without handle TPN Interior in sheet steel enclosure Interior with handle TP S-D-F Suitable for BS Fuses Interior with handle TPN Switch-Disconnector Interior with handle TPN SK95608 SK95609 SK95610 SK95611 SK95551 SK95710 SK95682 SK95590 SK95591 SK95592 SK95642 SK95641 SK95681 ST31731 SK95461 SK95460 SK95514 ST27897 SK95481 SK95480 SK95515 ST27898 SK95521 SK95520 SK95547 ST27899 SK95679 SK95678 SK95705 ST31732 FN 250 FN 315 FN 400 FN 630 FN 800 FN 1000

19

For selection and product demonstration, please contact any of our branch offices listed below:

REGISTERED OFFICE AND HEAD OFFICE L&T House, Ballard Estate P. O. Box 278 Mumbai 400 001 Tel: 022-67525656 Fax: 022-67525858 Website: www.Larsentoubro.com ELECTRICAL STANDARD PRODUCTS (ESP) 501, Sakar Complex Opp. Gandhigram Rly. Station Ashram Road Ahmedabad 380 009 Tel: 079-66304007-11, 55304000/1 Fax: 079-26580491 e-mail: esp-ahm@Lntebg.com 38, Cubbon Road, Post Box 5098 Bangalore 560 001 Tel: 080-25020100 / 25583613 Fax: 080-25580525 e-mail: esp-blr@Lntebg.com 131/1, Zone II Maharana Pratap Nagar Bhopal 462 011 Tel: 0755-6454906 / 7 / 8 / 9 Fax: 0755-2769264 e-mail: esp-bho@Lntebg.com Plot No. 559, Annapurna Complex Lewis Road Bhubaneswar 751 014 Tel: 0674-2537301, 2436696 Fax: 0674-2537309 e-mail: esp-bbi@Lntebg.com SCO 32, Sector 26-D Madhya Marg, P. O. Box 14 Chandigarh 160 026 Tel: 0172-4646841 / 2 / 3 / 4 / 5 / 6 / 7 Fax: 0172-4646802 e-mail: esp-chd@Lntebg.com 10, Club House Road Chennai 600 002 Tel: 044-28462072 / 4 Fax: 044-28462102 e-mail: esp-maa@Lntebg.com 67, Appuswamy Road Post Bag 7156 Opp. Nirmala College Coimbatore 641 045 Tel: 0422-2588120, 2588121 / 3 Fax: 0422-2588148, e-mail: esp-cbe@Lntebg.com

L&T House Group MIG - 5 Padmanabhpur Durg 491 001 Tel: 0788-2213833 / 14 / 28 / 29 Fax: 0788-2213820 A1/11, Astronauts Avenue Bidhan Nagar Durgapur 713 212 Tel: 0343-2536493 / 39 Fax: 0343-2536493 e-mail: esp-dgp@Lntebg.com (Faridabad Switchgear Works) 12/4, Delhi-Mathura Road Faridabad 121 003 Tel: 0129-2565147 / 8 Fax: 0129-2275405 e-mail: esp-fbd@Lntebg.com Milanpur Road, Bamuni Maidan Guwahati 781 021 Tel: 0361-2550565 Fax: 0361-2551308 e-mail: esp-gau@Lntebg.com 5-10-173, Fateh Maidan Road P. O. Box 12 Hyderabad 500 004 Tel: 040-66720251 Fax: 040-23242356 e-mail: esp-hyd@Lntebg.com D-24, Prithvi Raj Road C-Scheme Jaipur 302 001 Tel: 0141-2377374 / 2361064 Fax: 0141-2373280 e-mail: esp-jai@Lntebg.com Akashdeep Plaza, 2nd Floor P. O. Golmuri Jamshedpur 831 003 Jharkhand Tel: 0657-2340864, 2340308 Fax: 0657-2341250 e-mail: esp-jam@Lntebg.com Skybright Bldg. M. G. Road Ravipuram Junction Ernakulam Kochi 682 016 Tel: 0484-4409422 / 23 / 24 / 25 / 26 / 27 Fax: 0484-4409430 e-mail: esp-cok@Lntebg.com 3-B, Shakespeare Sarani Kolkata 700 071 Tel: 033-44002301 / 2 / 3 / 4 / 5, 44002572 Fax: 033-22821025 e-mail: esp-ccu@Lntebg.com

A28,Indira Nagar Faizabad Road Lucknow 226 016 Uttar Pradesh Tel: 0522-4040905 / 903 / 904 Fax: 0522-2311671 e-mail: esp-Lko@Lntebg.com Plot No. 518 4th Main Road K. K. Nagar Madurai 625 020 Tel: 0452-2537404 / 303 Fax: 0452-2537552 e-mail: esp-mdu@Lntebg.com North Wing, Level II, Gate 7, Powai Mumbai 400 072 Tel: 022-67050505 Fax: 022-67051112 e-mail: esp-bom@Lntebg.com 8B, Farmland, Ramdaspeth Behind Hotel Radhika Nagpur 440 010 Tel: 0712-2420641 / 24 Fax: 0712-2420619 e-mail: esp-ngp@Lntebg.com 32, Shivaji Marg, P.O. Box 6223 New Delhi 110 015 Tel: 011-51419500 / 1 , 51419515 Fax: 011-51419600 e-mail: esp-del@Lntebg.com L&T House, P.O. Box 119 191/1, Dhole Patil Road Pune 411 001 Tel: 020-66033395 / 88 / 89 Fax: 020-26129586 e-mail: esp-pnq@Lntebg.com 3rd Floor, Vishwakarma Chambers Majura Gate, Ring Road Surat 395 002 Tel: 0261-2473726 Fax: 0261-2477078 e-mail: esp-sur@Lntebg.com Radhadaya Complex Old Padra Road Near Charotar Society Vadodara 390 015 Tel: 0265-6613611 Fax: 0265-2336184 e-mail: esp-bar@Lntebg.com 48-8-16, Dwarakanagar Visakhapatnam 530 016 Tel: 0891-2755493, 2704928 Fax: 0891-2746075 e-mail: esp-viz@Lntebg.com

Product improvement is a continuous process. For the latest information and special applications, please contact any of our offices listed here.

Electrical Standard Products

Larsen & Toubro Limited


Powai Campus, Mumbai 400 072 Tel: 022-6705 0505 Fax: 022-67051324 / 1746 E-mail: esp@LNTEBG.com Website: www.LNTEBG.com

SP 50452

190607

Vous aimerez peut-être aussi