Vous êtes sur la page 1sur 9

SD SWMDX SWM DIPLEXER COMPARISON

SWM to (CATV+SWM)
DC -1 -30 -45 -50 2 47 625 806 940 475 2150

1
2150

CATV to (SWM+CATV)
DC -1 -25 -45 2 47 806 940

SD SWMD1

-60

Model SD SWMD1 provides 60 dB of isolation of the 2.3 MHz SWM control signal from the CATV+SWM port to the CATV port.

The 2.3 MHz from apartment 1 is prevented from mixing with the 2.3 MHz signal from apartment 2 in the CATV network.

(CATV+SWM) to DBS
DC -1 -10 -25 -35 2 47 625 806 940 475 2150

(CATV+SWM) to CATV
DC -1 -20 2 47 806 940 2150

SD SWMD2

-35

Model SD SWMD2 is intended for CATV and SWM separation or combining where isolation is less critical.

Model SD SWMD2 features low in-band insertion loss. SWM control 2.3 MHz and MRV / DECA isolation is 35 dB minimum.

SWM to (CATV+SWM)
DC -1 -30 -45 -60 247 625 806 940 475 2150

CATV to (CATV+SWM)
DC -1 -25 -45 2 47 806 940 2150

SD SWMD3

-60

Model SD SWMD3 is intended for CATV and SWM isolation where both 2.3 MHz and MRV filtering is critical. The D3 adds a band reject filter at 475 to 625 MHz.

The SD SWMD3 is suggested for applications where MRV filtering occurs in a single diplexer.

Revised Nov 3 2011

Contact: Sonora Design Associates 805.644.8913 www.sonoradesign.com info@sonoradesign.com

SD SWMDX SWM DIPLEXER COMPARISON

Parameter
Frequency Range CATV PORT SWM PORT CATV+SWM PORT Insertion Loss CATV (7 to 806 MHz) SWM (0.3 to 2.3 MHz) SWM (940 to 2150 MHz) Rejection of SWM @ CATV Port CATV (0.3 to 2.3 MHz) CATV (4 MHz) CATV (940 to 2150 MHz) Rejection of CATV @ SWM Port SWM (7 to 40 MHz) SWM (51 to 806 MHz) SWM MRV (475 to 675 MHz) Return Loss CATV (7 to 40 MHz) CATV (54 to 806 MHz) SWM (0.3 to 2.3 MHz) SWM (940 to 2150 MHz) Flatness CATV (7 to 806 MHz) CATV (Any 6 MHz band) SWM (940 to 2150 MHz) SWM (Any 25 MHz band) DC Power pass (CATV+SWM to SWM) Dimensions L x W x H Environmental Requirements Operating Temperature range Humidity: Shall survive:

UNIT
MHz MHz MHz dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB dB Amp mm C

SD SWMD1
7 - 806 0.3 - 2.3 & 940 -2150 0.3 -2150 <2.0 <2.0 <2.0 >55 >25 >45 >50 >45 >45 >10 >12 >12 >10 1.5 0.5 1.5 0.5 2 (max) 70 x 34 x 28 Indoor Only -34 to + 60

SD SWMD2
7 - 806 0.3 - 2.3 & 940 -2150 0.3 -2150 <2.0 <2.0 <2.0 >30 >20 >35 >25 >35 >35 >10 >12 >12 >10 1.5 0.5 1.5 0.5 2 (max) 60 x 51 x 16 Indoor Only -34 to + 60

SD SWMD3
7 - 806 0.3 - 2.3 & 940 -2150 0.3 -2150 <2.0 <2.0 <2.0 >55 >25 >45 >50 >45 >55 >10 >12 >12 >10 1.5 0.5 1.5 0.5 2 (max) 70 x 34 x 28 Indoor Only -34 to + 60

95% relative humidity over 95% relative humidity over 95% relative humidity over operating temperature operating temperature operating temperature

Revised Nov 3 2011

Contact: Sonora Design Associates 805.644.8913 www.sonoradesign.com info@sonoradesign.com

CUSTOM HOME OFF-AIR & SL5S


-30 dBm SL5S -20 dBm 34 dBmV
DBS

20 dBmV
ANT

Model AD14 amplifies both Off-Air and SWM signals and combines the signals on a single coax. Power passes from the amplifier to the SL5S LNB. NO power passes to the Off-Air antenna. Model HRPIR242 inserts 24 VDC power. Multi-room viewing is not possible with OFF-Air signals present. MRV frequencies of 475 to 625 MHz fall in the UHF off-ar band channels 14 to 41. Maximum drop length is extended to 100 feet RG-6. The (8) room example illustrates outlets at 50, 75, 100 and 150 feet of coax from the splitter.
1

AD14
RECEIVER

-28 dBm 30 dBmV @ 100 ft

24V 2A HRPIR 242

HRvS8P

-41 dBm 15 dBmV

MPOE
-54 dBm 9 dBmV @ 150 ft

-45 dBm 13 dBmV @ 50 ft

At each receiver the combined signal is separated with


SAT IN

SAT IN

D12

D12

a diplexer. An AM21 Off-Air receiver or the TV tuner can be used to receive the off-air signal.
2

-50 dBm 11 dBmV @ 100 ft


SD SWMD3 SWM
Off-Air SAT1 SWM2

-49 dBm 12 dBmV @ 75 ft


CATV

Receivers not emitting MRV signals in the 475 to 625 MHz


RECORDING PROGRAM

SD SWMD3 SWM

band require just a SD SWMD2 diplexer. Receivers which transmit MRV require a SD SWMD3 diplexer with built in MRV band stop filtering.

CATV

AM-21 Off-Air Tuner

Off-Air SAT1 SWM2

AM21 Off-Air Tuner

H21

SAT2 IN

HR21 DVR

-30 dBm SL5S -20 dBm 34 dBmV


DBS

20 dBmV
ANT

AD14
RECEIVER

-32 dBm 28 dBmV @ 150 ft

INPUT RTN & DC OUT

24 VDC
AMP & INPUT

12 to 24 VDC
AMP ONLY

HRvS8P
PS24 2000A

LA141R DBS AMPLIFIER R I

FORWARD : 54 to 3000 MHz ..14 dB RETURN : 2 to 40 MHz .... -1 dB

5V

OUTPUT RTN & DC IN

24 VDC
AMP & INPUT

12 to 24
VDC AMP

-33 dBm 16 dBmV

Model LA141R-T24 amplifies both Off-Air and SWM signals and provides the 24 VDC powering for the AD14 and SL5S LNB. Adding the LA141R-T24 extends the in dish to receiver distances another 150 feet.

MPOE
-55dBm 6 dBmV @ 250 ft

-18 dBm 36 dBmV -38 dBm 14 dBmV @ 50 ft

In this application the dish is 150 feet from the MPOE and the furthest receiver is 250 feet form the 8-way splitter.

SAT IN

D12

SAT IN

D12

-48dBm 10 dBmV @ 150ft


SD SWMD3 SWM
Off-Air SAT1 SWM2

-43 dBm 12 dBmV @ 100 ft


CATV

2
RECORDING PROGRAM

SD SWMD3 SWM

CATV

AM-21 Off-Air Tuner

Off-Air SAT1 SWM2

AM21 Off-Air Tuner

H21

SAT2 IN

HR21 DVR

Revised Nov 3 2011

Contact: Sonora Design Associates 805.644.8913 www.sonoradesign.com info@sonoradesign.com

MDU SMATV SWM16 DIPLEXING


+18 dBmV +14 dBmV -28 dBm
SWM

IDF CLOSET
GHS2

PS24 2000A

SWM16
Legacy 1 Legacy 2 Legacy 3 Legacy 4 FLEX1 OUT FLEX2 OUT 103/110
/119 99/101
18V 13V 18V 22k 13V 22k Flex Flex Port1 Port2

(CATV+SWM) to SWM
DC -1
CATV

2 47

675 806 940

2150

SWM1 PWR
SD SWMD1

DC/PWR SWM2
SWM

-30 -45 -50


SD SWMD1
CATV

-29 dBm +13 dBmV


HRvS2D HRvS2D

(SWM+CATV) to CATV
DC -1 -25 -45 -60 2 47 806 940 2150

-34 dBm +9 dBmV

100 ft RG6
-43 dBm +4 dBmV

CATV to (SWM + CATV)


DC -1 -25 -45 -60 2 47 806 940 2150
CATV

SWM to (CATV+SWM)
SD SWMD3 SWM
DC -1 -30 -45 -60 247 625 806 940 475 2150

+3 dBmV
ROUTER
CABLE IN

-44 dBm
MSAT2

50 ft RG6
DBS

CABLE MODEM

H24 HD RCVR

-48 dBm

APARTMENT 1
-53 dBm
SAT1 SWM2 SAT2 IN

RECORDING PROGRAM

HR21 DVR

A Satellite Master Antenna TV (SMATV) system controlled and owned by the system operator has cable frequencies 54 to 806 MHz forward and 7 to 40 MHz return. Both the SWM signals and the SMATV signals are to be delivered to each apartment on a single coax. DIRECTV mutli-room viewing (MRV) sends high level signals in the 475 to 625 MHz band from receivers. Model H24 and HR24 ship with multi-room viewing enabled. MRV and SMATV signals CAN NOT share the same coax. Filtering is required to keep the MRV signals within the apartment.

Models SD SWMD1 and SD SWMD3 internally filter two frequency bands of CATV (7 to 40 MHz & 54 to 806 MHz) and three bands of DIRECTV; DC to 2.3 MHz, 475 to 625 MHz and 940 to 2150 MHz. SMATV signals from 7 MHz to 806 MHz are combined with the SWM16 940 to 1840 MHz output in model SD SWMD1. The SD SWMD1 features 60 dB isolation of the 2.3 MHz SWM control signal to the CATV input. It also provides sharp filtering to allow the CATV 7 -40 MHz sub-band to pass to the apartment. Model SD SWMD3 separates the CATV signals to feed the Cable Modem. Cable Modem 7 to 40 MHz return signals pass back to the IDF closet. The SD SWMD3 features a band reject filter for the MRV 475 to 625 MHz signals generated by the DIRECTV receivers.
Revised Nov 3 2011

Contact: Sonora Design Associates 805.644.8913 www.sonoradesign.com info@sonoradesign.com

SMATV SWM16 AMPLIFIED DIPLEXING


+18 dBmV
GHS2

SWM16
Legacy 1 Legacy 2 Legacy 3 Legacy 4 FLEX1 OUT FLEX2 OUT 103/110
/119 99/101
18V 13V 18V 22k 13V 22k Flex Flex Port1 Port2

-28 dBm
SWM

+14 dBmV
CATV

SWM1 PWR
SD SWMD1

DC/PWR SWM2
SWM

(4) OUTLET, SWM, MRV & SMATV Apartment


-39 dBm 4 dBmV
MSAT-4
CATV

RG6
SD SWMD1
CATV

SD SWMD3 SWM

-40 dBm -49 dBm


ROUTER
CABLE IN

HRvS2D

3 dBmV
SWM 24V 12V

LA141R
OUT 24V 12V

MPOE
PS24 2000A

CABLE MODEM

-55 dBm @ 75 ft
BS

4
PC

-20 dBm +18 dBmV

HRvS2D
ANT IN

Model LA141R-T24 amplifies both SMATV and SWM signals. Power passes from the amplifier through the SD SWMD1 to power the SWM16. Maximum drop length is extended to 225 feet RG-6 for apartments with (4) outlets and 75 feet internal apartment coax.
PS 12 200

SAT IN

D12

-50 dBm @ 50 ft

-48 dBm @ 25 ft
RECORDING PROGRAM

SWM

H24 HD RCVR

SAT1 SWM2

SAT2 IN

HR24 DVR

CA14R
IN DC OUT

+24 dBmV
GHS2

+10 dBmV

SWM16
Legacy 1 Legacy 2 Legacy 3 Legacy 4 FLEX1 OUT FLEX2 OUT 103/110
/119 99/101
18V 13V 18V 22k 13V 22k Flex Flex Port1 Port2

-28 dBm
SWM

+20 dBmV
CATV

(4) OUTLET, SWM & SMATV, NO MRV Apartment


-39 dBm 13 dBmV
HRvS4P

SWM1 PWR
SD SWMD1

DC/PWR SWM2
SWM

RG6
SD SWMD1
CATV

-48 dBm 6 dBmV


ROUTER

HRvS2D

MPOE
-55 dBm 3 dBmV @ 75 ft

CABLE MODEM

CABLE IN

4
PC

SWM

24V

12V

LA141R
OUT 24V 12V

PS24 2000A

-20 dBm +24 dBmV

SAT IN

D12

HRvS2D

MRV signals from receivers can be blocked by model SD SWMD3 so SMATV and SWM signals can share the single coax all the way to the receiver. Higher SMATV levels are required to push the SMATV deeper in the apartment. Model LA141R-T or model LA281R-T may be used to increase the SWM & SMATV levels by 14 or 28 dB respectively.

-52 dBm 4 dBmV @ 50 ft


SD SWMD3 SWM
Off-Air SAT1 SWM2

-50 dBm 5 dBmV @ 25 ft


CATV

2
RECORDING PROGRAM

SD SWMD3 SWM

CATV

AM-21 Off-Air Tuner

Off-Air SAT1 SWM2

AM21 Off-Air Tuner

H21

SAT2 IN

HR21 DVR

Revised Nov 3 2011

Contact: Sonora Design Associates 805.644.8913 www.sonoradesign.com info@sonoradesign.com

MOTEL SWM16 DRE DECA DIPLEXING


SWM16
Legacy 1 Legacy 2 Legacy 3 Legacy 4 FLEX1 OUT FLEX2 OUT 103/110
/119 99/101
18V 13V 18V 22k 13V 22k Flex Flex Port1 Port2

-28 dBm
SWM

SWM1 PWR DC/PWR SWM2

IDF CLOSET
24V 12V

PS24 2000A

LA141R
OUT 24V 12V

INTERNET
PS24 2000A

-14 dBm

DECA
-28 dBm
SWM

DECA
LEVEL 3 SWITCH

SWM to (CATV+SWM)
DC -1 -30 -45 -60 247 625 806 940 475 2150

(CATV+SWM) to DBS
DC 2 47 675 806 940 2150 -1 -10 -25 -35

SD SWMD3

CATV

CATV to (SWM+CATV)
DC -1 -25 -45 -60 2 47 806 940 2150

-29 dBm HRvS8P -44 dBm

-15 dBm (CATV+SWM) to CATV


DC 2 47 806 940 2150

HRvS8P -30 dBm

-1 -20 -35

ROOM 1O1

100 ft RG6

250 ft RG6

ROOM 2O1

DBS

H25 HD RCVR

SWM

H25 HD RCVR

-55 dBm Minimum

-55 dBm Minimum

SONORA models SD SWMD2 and SD SWMD3 internally filter two frequency bands of CATV (7 to 40 MHz & 54 to 806 MHz) and three bands of DIRECTV ( DC to 2.3 MHz, 475 to 625 MHz and 940 to 2150 MHz). DECA signals from 475 MHz to 625 MHz are combined with the SWM16 940 to 1840 MHz output. The SD SWMD3 features 60 dB isolation of the DECA signals from reaching the SWM2 output. We do not want DECA signals combining with SWM1 to mix with DECA signals combining with SWM2. Note that in the SWM16 there is 6 dB isolation of the DECA from SWM1 to SWM2.

Model LA141R-T may be used with model SD SWMD2 to extend the IDF to receiver drop distance by 150 feet. Less 475 to 625 MHz DECA isolation is required in the SD SWMD2 when proceeded with the LA141R-T amplifier. The amplifier blocks the DECA signal from reaching the SWM1 output. For DRE applications a SWM output is split (8) ways to serve (8) rooms. There is (1) DECABB1MR0-01 adaptor to serve the (8) rooms. The 2.3 MHz isolation in the SD SWMD2 is sufficient for this application.

Revised Nov 3 2011

Contact: Sonora Design Associates 805.644.8913 www.sonoradesign.com info@sonoradesign.com

SD SWMD1 SWM DIPLEXER TEST DATA

SWM Port to SUM Port 300 kHz to 15 MHz 1 = 300 kHz = -0.3 dB 2 = 2.3 MHz = -0.7 dB 3 = 4 MHz = -40 dB 6 = 7 MHz = -48 dB

SWM Port to SUM Port 300 kHz to 2.2 GHz 1 = 50 MHz = -60 dB 7 = 400 MHz = -46 dB 3 = 940 MHz = -1.4 dB 6 = 2150 MHz = -1.2 dB

CATV Port to SUM Port 300 kHz to 15 MHz 1 = 300 kHz = -78 dB 2 = 2.3 MHz = -63 dB 3 = 4 MHz = -30 dB 4 = 7 MHz = -1.4 dB

CATV Port to SUM Port 300 kHz to 2.2 GHz 1 = 50 MHz = -0.15 dB 2 = 806 MHz = -1.3 dB 3 = 940 MHz = -50 dB 6 = 2150 MHz = -47 dB

Revised Nov 3 2011

Contact: Sonora Design Associates 805.644.8913 www.sonoradesign.com info@sonoradesign.com

SD SWMD2 SWM DIPLEXER TEST DATA

SWM Port to SUM Port 300 kHz to 15 MHz 1 = 300 kHz = -0.3 dB 2 = 2.3 MHz = -0.7 dB 3 = 4 MHz = -40 dB 6 = 7 MHz = -48 dB

SWM Port to SUM Port 300 kHz to 2.2 GHz 1 = 50 MHz = -60 dB 7 = 400 MHz = -46 dB 3 = 940 MHz = -1.4 dB 6 = 2150 MHz = -1.2 dB

CATV Port to SUM Port 300 kHz to 15 MHz 1 = 300 kHz = -74 dB 2 = 2.3 MHz = -44 dB 4 = 4 MHz = -35 dB 5 = 7 MHz = -1.5 dB

CATV Port to SUM Port 300 kHz to 2.2 GHz 9 = 20 MHz = -0.3 dB 6 = 806 MHz = -1.4 dB 7 = 940 MHz = -60 dB 8 = 2150 MHz = -41 dB

Revised Nov 3 2011

Contact: Sonora Design Associates 805.644.8913 www.sonoradesign.com info@sonoradesign.com

SD SWMD3 SWM DIPLEXER TEST DATA

SWM Port to SUM Port 300 kHz to 15 MHz 1 = 300 kHz = -0.1 dB 2 = 2.3 MHz = -0.7 dB 3 = 4 MHz = -40 dB 6 = 7 MHz = -48 dB

SWM Port to SUM Port 300 kHz to 2.2 GHz 2 = 50 MHz = -68 dB 3 = 475 MHz = -64 dB 4 = 675 MHz = -67 dB 6 = 940 MHz = -1.6 dB 8 = 2150 MHz = -1.7 dB

CATV Port to SUM Port 300 kHz to 15 MHz 1 = 300 kHz = -83 dB 2 = 2.3 MHz = -68 dB 3 = 4 MHz = -29 dB 4 = 7 MHz = -1.2 dB

CATV Port to SUM Port 300 kHz to 2.2 GHz 2 = 50 MHz = -0.1 dB 5 = 806 MHz = -1.6 dB 6 = 940 MHz = -47 dB 8 = 2150 MHz = -46 dB

Revised Nov 3 2011

Contact: Sonora Design Associates 805.644.8913 www.sonoradesign.com info@sonoradesign.com